OPGW / OPPC solution - saltec.de · Engineering Works OPGW/OPPC system design, design sag‐calculation Testing Type‐, routine‐and sample testing Factory acceptance tests Special

May 21, 2018

Download

Documents

vuongmien
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: OPGW / OPPC solution - saltec.de · Engineering Works OPGW/OPPC system design, design sag‐calculation Testing Type‐, routine‐and sample testing Factory acceptance tests Special
Page 2: OPGW / OPPC solution - saltec.de · Engineering Works OPGW/OPPC system design, design sag‐calculation Testing Type‐, routine‐and sample testing Factory acceptance tests Special

Long Span Length > 1,8 km Span OPPC – up to 400 kV

OPGW / OPPC and Accessories System Solution

Page 3: OPGW / OPPC solution - saltec.de · Engineering Works OPGW/OPPC system design, design sag‐calculation Testing Type‐, routine‐and sample testing Factory acceptance tests Special

OPGW / OPPC solution

Page 4: OPGW / OPPC solution - saltec.de · Engineering Works OPGW/OPPC system design, design sag‐calculation Testing Type‐, routine‐and sample testing Factory acceptance tests Special

Used fibres adding flexibility and future to fibre network 

SMF‐28e+ ‐ extending G652 standard – Improved bending – Advanced technology for future 

networks 

G657 Fibre optimised for Access‐network and broadband installation in house – Specified microbending down to 

5mm bend radius 

Fibres used in cables designs G655 NZDS‐Fibre optimised 

for Long Haul Terrestrial network– Industry leading specification – Lowest PMD available

Page 5: OPGW / OPPC solution - saltec.de · Engineering Works OPGW/OPPC system design, design sag‐calculation Testing Type‐, routine‐and sample testing Factory acceptance tests Special

have to be resistant against stress of…  Installation  Ice loads  Temperature change  Lightning impact  Short circuit currents  Wind loads 

therefore our OPGW / OPPC designs provide…

OPGW and OPPC

Page 6: OPGW / OPPC solution - saltec.de · Engineering Works OPGW/OPPC system design, design sag‐calculation Testing Type‐, routine‐and sample testing Factory acceptance tests Special

high fibre excess length of approx. 5‰, to compensate high strain stresses in case of strong ice‐ or wind loads all materials being highly corrosion resistant  high mechanical flexibility avoiding long term fatigue and breaks of the wires and the optical fibre unit in case of high vibration stress

Design Features

Page 7: OPGW / OPPC solution - saltec.de · Engineering Works OPGW/OPPC system design, design sag‐calculation Testing Type‐, routine‐and sample testing Factory acceptance tests Special

Faultless operating of the fibers requires a proper protection against mechanical and thermal stress. 

nkt manufacturers tubes from seamless welded stainless steel which protect the fibers 

against various mechanical impacts, moisture and heat. 

They are placed as a loose buffer in the center or in the first layers of the cable. 

The fibers are embedded with a defined over length and space for movement in a special heat resistant and moisture repellent gel, to withstand bending, vibration, elongation and temperature variation. 

Steel tube design description

Page 8: OPGW / OPPC solution - saltec.de · Engineering Works OPGW/OPPC system design, design sag‐calculation Testing Type‐, routine‐and sample testing Factory acceptance tests Special

All material are specially choosen to exclude corrosionExample:  OPPC without Grease!!!  4 layer design  Salt Spray Corrosion Test: according to UNE‐

EN ISO 9227 NSS (07) or ASTM B‐117(09), during 1000 hours. 

Result no significant corrosion ! 

Excelent protection against corrosion

Page 9: OPGW / OPPC solution - saltec.de · Engineering Works OPGW/OPPC system design, design sag‐calculation Testing Type‐, routine‐and sample testing Factory acceptance tests Special

Excellent fibre protection in case of short circuit  Example short circuit test 3 layer design: 

Test according to IEC 60794‐4‐1  Temperature far below max of the conductor  No attenuation change 

Fibre protection

Page 10: OPGW / OPPC solution - saltec.de · Engineering Works OPGW/OPPC system design, design sag‐calculation Testing Type‐, routine‐and sample testing Factory acceptance tests Special

Continuous operation during / after lightning test  Test performed according IEC 60794‐1‐2  Fibre: No attenuation change < +/‐ 0,05 

dB/km  High remaining RTS in case of broken wires

Fibre protection

Page 11: OPGW / OPPC solution - saltec.de · Engineering Works OPGW/OPPC system design, design sag‐calculation Testing Type‐, routine‐and sample testing Factory acceptance tests Special

Engineering Works OPGW/OPPC system design, design sag‐calculation 

TestingType‐, routine‐ and sample testing Factory acceptance tests Special optical and mechanical tests 

SupervisionStringing and installation of Joint boxes and OPPC accessories 

Measurement Services Optical measurements at site 

Installation including splicing of (subcontracted) OPGW Joint Boxes OPPC Termination Units and OPPC straight Joints 

Installation Training

What Services do we provide?

Page 12: OPGW / OPPC solution - saltec.de · Engineering Works OPGW/OPPC system design, design sag‐calculation Testing Type‐, routine‐and sample testing Factory acceptance tests Special