133 122 | cabac.com.au REV1 / October’20 TEST MEASUREMENT
133 122 | cabac.com.auREV1 / October’20
TESTMEASUREMENT
2 cabac.com.au133 122
1. CAT IThis covers measurements performed on circuits not connected directly to the mains. Surges in an electronic device e.g. a PCB inside a photocopier, may have some electronic ripple.2. CAT IIFor measurements on circuits connected directly to the low voltage installation e.g an appliance. Appliances such as power tools or household appliances and the electrical cord may have low surges from a motor for example.3. CAT IIIFor measurements of the circuit in a building installation i.e. plugs and sockets, distribution boards, lighting circuits, underground cable, boreholes connected by underground cable, etc. e.g. dissipated lightning surges.4. CAT IVFor measurements at the source of an electrical installation. This covers outside supply lines, overhead lines and the main board connected to overhead lines. These electrical circuits are exposed to substantial surges such as lightning.
Handy Info (IEC61010-1 2010)Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements. Explanation of categories listed in clause 6.7.4
The table on the right indicates the applied voltages (BIL) of an impulse generator. The generator shall produce an open circuit voltage waveform of 1,2/50ms.
Impulse Withstand Voltages for the IEC61010 Categories
Nominal Voltages Voltage Transients
Phase toNeutral Voltage*
Transient stresses estimated within the installation without any over-voltage limiting devices
CATII CATIII CATIV50 500 800 1500
100 800 1500 2500
150 1500 2500 4000
300 2500 4000 6000
600 4000 6000 8000
1000 6000 8000 12000
Output Impedance of Impulse Generator 12Ω 2Ω 2Ω
Loop Impedance is the sum of impedances in a circuit measured from an outlet point to the supply transformer via active or neutral or earth and the respective return in the loop. PSC is the prospective short circuit current that the loop will carry due to the resistance and applied voltage.
The T2726 Loop Impedance Tester will display in scrolling order, the line voltage, the sum of and individual impedances and the prospective short circuit current (PSC) in loops Active/Neutral and Active/Earth. The instrument calculates the PSC using the recorded voltages and measured impedances. To obtain accurate milliohm values the instrument uses a high test current, which will trip the RCD. The RCD should be by-passed and the load on the circuit minimized before the test is done. Instruments that do not trip the RCD use test currents below 20mA and are not as accurate as when using a higher current test. Determining the PSC is useful to determine the maximum load protection on a circuit e.g. a class C circuit breaker needs to trip at 7.5 times its rated current and the circuit must be able to carry it.
A loop impedance meter will test neutral integrity according to AS4741 as per Appendix B Method B3.
Drawing 1 – Physical Layout of Supply Loops
Meter Board
Transformer
AN
E
Pole Fuse
Active
Neutral
MENLINK
Drawing 2 – Earth Fault Loop
Notes on Loop Impedance
3cabac.com.au 133 122
Triple R Service & Calibration Policy
Certificate of Quality
CABAC confirms herein that the unit you have purchased has been calibrated, during
the manufacturing process, in compliance with the test procedures defined by CABAC
and the manufacturer.
All CABAC procedures are monitored on a permanent basis in compliance with
ISO 9000 Quality Management Standards.
In addition CABAC confirms that all test equipment and instruments used during the
calibration process are subject to constant control. All test equipment and instruments
used are calibrated at determined intervals, using reference equipment, which has
been calibrated in compliance with (and traceable to) the calibration standards of
international laboratories and the country of manufacturer’s national standards.
The factory settings are valid for a period of one year from the date of purchase from
your reseller.
CABAC test and measurement equipment complies with Australian EMC regulatory
and international requirements.
CABAC Test Equipment
CABAC Test EquipmentIdeal for professional use in industrial, electrical applications, field environments, laboratory or workshop applications there’s a model to suit every need.
CABAC test equipment use the latest microprocessor technology to provide comprehensive measuring ranges and features in hand held instruments. There is a wide range of test and measurement equipment to suit all applications and budgets.
All products conform to International Standard requirements, and all carry a long list of exclusive features. Some models have “Lifetime of Product Warranty” as standard, and all are backed by the CABAC name for quality.
Whether you are buying a general purpose unit, that has advanced features such as auto ranging, data hold, auto power off, reinforced case for durability, etc. or a professional range unit which offers additional features and accessories, the CABAC range of test equipment will suit your work requirements and provide you with many years of reliable service.
Some models have “Lifetime of Product Warranty”
*Refer to CABAC website cabac.com.au for terms and conditions on warranty.
CABAC OFFERS A CALIBRATION SERVICE FOR INSTRUMENTS The Calibration can either be Factory Standard calibration or independent external NATA accredited calibration. Please note part numbers for calibration of Multimeters, Clamp meters, Installation testers, Multi-function and appliance testers. An installation tester is defined as an instrument that conducts RCD, LOOP or Insulation testing. Multifunction testers which encompass all these testers in the one unit will attract a higher calibration price due to the extra time taken to check all functions.
Part Number DescriptionCALNATAMM NATA Calibration MultimeterCALNATAIMF NATA Calibration Multifunction TestersCALNATACLAMP NATA Calibration ClampCALNATAAPP NATA Calibration Appliance TestersCALNATAINS NATA Calibration Installation Testers
Part Number Description CALSTANMM Factory Calibration MultimeterCALSTANMF Factory Calibration Multifunction TestersCALSTANCLAMP Factory Calibration ClampCALSTANAPP Factory Calibration Appliance TestersCALSTANINS Factory Calibration Insulation Testers
On accepting an instrument to be repaired the following procedure is to take place.
1st R REPAIR1. Provide a quote for labour and parts to repair the instrument to manufacturers specifications. 2. Repair the instrument after receiving written acceptance of the quotation (a purchase order from the
referring wholesale branch is sufficient).3. The work shall be warranted for a maximum of 3 months.
2nd R REPLACEIf the customer elects not to have the instrument repaired then they have the choice to accept as close an equivalent as possible an instrument we supply at a price suggested by the referring wholesaler or pay the minimum quotation fee for the time taken to diagnose the problem. Please note:* The quotation of repair and replacement parts is subject to availability from the supplier especially
in the case of meters not sold by CABAC.* The quotation fee will be waived if the customer purchases one of our suggested replacement
meters.
3rd R RETURNIf the customer elects to pay the quotation fee we will return the instrument to the referring wholesale branch.Please note: *The quotation fee will be charged to the referring wholesaler for unclaimed goods left for more than 3 months.
4 cabac.com.au133 122
Part No. C505 •High quality taut band movement •IEC61010 CAT III 600V •Manual scale selection •Easy to read 3-colour scale •Mirror scale for accuracy
PROFESSIONAL ANALOGUE MULTI METER
MULTIMETERS
Unit: EA Qty: 1
Part No. TBM27 •Pocket size - small and compact DMM with EF test and low 2 mA current. •3 5/6 digit 6000 count LCD •Data hold, continuity and diode test •Electric Field (NCV) detection, unit updates 5x per second •HI-Z DCV & ACV
DELUX POCKET DMM Unit: EA Qty: 1
Part No. T8211D •Pen type digital multimeter for testing AC and DC voltage and resistance •IEC61010 CATII 600V •Maximum and data hold •Audible and visual flashing alarm with retractable probe on meter •Suitable for electronic and appliance testing
PEN TYPE METER Unit: EA Qty: 1
Part No. C187 •3 1/2 digit, 4000 count LCD digital multimeter with LAN cable pin to pin testing •Voltage and resistance DMM. CATIII 600V •Data hold, continuity, diode test 7 low battery indication •RJ45/RJ11 pin ot pin testing with/without remote receiver •Ideal instrument for the data cable installer electrician
DMM LAN CABLE TESTER Unit: EA Qty: 1
Part No. T8268 •Autoranging DMM featuring audible and visual lead input socket selection
indication •3 1/2 digit 1999 count LCD •CATIII 600V and backlight LCD •Maximum, relative and data hold •hfe transistor test
AUTO RANGE DIGITAL MULTIMETER Unit: EA Qty: 1
5cabac.com.au 133 122
Part No. TBM685 •Rugged and compact voltage, resistance, capacitance and continuity digital
multimeter •IEC 61010CATIV 1000V •Electric Field (NCV) detection strength indication •AutocheckTM Voltage and resistance •Data hold Function
DELUX AUTOCHECK DIGITAL MULTIMETER Unit: EA Qty: 1
Part No. BM251 •Economical, compact multimeter forcontractor’s daily use - functions: data hold,
relative measurement and electric field testing •IEC61010 CATIII 600V & Beep-Jack lead input warning •3 5/6, 6000 count LCD •Electric field test (EF), frequency (Hz) •PC interface with optional BRUA-20X software pack
GENERAL PURPOSE DIGITAL MULTI METER Unit: EA Qty: 1
Part No. TBM805 •Digital multimeter with BEEP-JACK input warning •IEC61010 CATIII 600V •3 ¾ digit 4000 count LCD •Rugged splash-proof housing •Maximum, relative zero and data hold
PRACTICAL PROFESSIONAL DMM Unit: EA Qty: 1
Part No. T8229 •Autoranging DMM, 5 in 1 feature packed with lux, humidity and sound
measurement •CAT III 600V, 3 ¾ 3999 count LCD •Audible & visual socket correct lead input indication •Data hold and relative measurement •Temperature measuremt with type-k thermocouple
5 IN 1 AUTO RANGE DIGITAL MULTIMETER Unit: EA Qty: 1
Part No. BM257 •Compact True RMS DMM, 3 5/6 digit, 6000 count LCD with 24 segment bargraph
and EF bar indication. •CatIV 300V, CATIII 600V, CATIV 300V •Extra feature: min/max, relative zero, crest & data hold •Backlight LCD, Beep-Jack input socket warning •PC interface USB/RS232 (Optional Kit)
MULTIMETER TRUE RMS W/ EF-DETECTION Unit: EA Qty: 1
6 cabac.com.au133 122
Part No. TBM807 •True RMS measurement digital multimeter with BEEP-JACK and temperature
range •IEC61010 CATIII 600V •3 ¾ digit 4000 count LCD •Rugged splash-proof housing •Maximum, relative and data hold
TRUE RMS PRACTICAL PROFESSIONAL DMM Unit: EA Qty: 1
Part No. BM821 •Digital multimeter, autoranging with good accuracy and data hold •4 Digit 6000/10000 count dual display LCD •IEC61010 CATIV 1000V •Beep-Jack input warning •Optional PC interface with BU-86X software pack
PROFESSIONAL DIGITAL MULTIMETER Unit: EA Qty: 1
Part No. BM869 •DMM, high performance technicians or engineers. Very accurate and feature
packed multimeter •4 4/5 digit, 50 000 count dual display LCD, backlight •IEC61010 CATIV 1000V, BeepJack input warning •Max/Min/Ave recording, relative zero, crest & data hold •% 4-20 mA loop,dual temperature, optional PC interface
PROFESSIONAL DMM HIGH PERFORMANCE Unit: EA Qty: 1
Part No. BM822 •Digital multimeter, True RMS, autoranging with good accuracy, relativezero & data
hold •4 digit 6000/10000 count, dual display LCD with bargraph •IEC61010 CATIV 1000V •Beep-Jack input warning •Optional PC interface with BU-86X software pack
PROFESSIONAL DMM TRUE RMS Unit: EA Qty: 1
Part No. BM827 •Digital multimeter, True RMS, autoranging feature packed, relative zero, Min/Max,
Crest Hold & Data Hold •4 digit 6000/10000 count, dual display LCD with bargraph •IEC61010 CATIV 1000V •Beep-Jack input warning •Optional PC interface with BU-86X software pack
PROFESSIONAL TRUE RMS DIGITAL MULTIMETER Unit: EA Qty: 1
7cabac.com.au 133 122
Part No. BM867 •DMM, high performance technicians or engineers. Very accurate digital and feature
packed •4 4/5 digit, 50 000 count dual display LCD •IEC61010 CATIV 1000V •Max/Min/Ave recording, relative zero, crest & data hold •%4-20 mA loop, BeepJack input warning, optional PC interface
PROFESSIONAL DMM TRUE RMS Unit: EA Qty: 1
Part No. BM319 •3 5/6 digit 6000 count LCD, feature packed automotive DMM •Dwell-angle, % -duty function, IGRPM & IP-RPM •Temperature, capacitance and 600mA ac/dc •Suitable for 2&4 stroke, 2&4 stroke-DIS •CATIII 600V, CATIV 300V• Optional accessory: BM-BP300 Inductive Pick-up Clip
Automotive DMM Unit: EA Qty: 1
Part No. BM525 •True RMS logging digital multimeter, feature packed with high accuracy •IEC61010 CATIV 1000V •4 Digit 6000/10000 count dual display LCD •Max/Min/Avg Recording & data logging memory •Optional PC interface capability with BU-86X software pack
PROFESSIONAL DMM TRUE RMS DATA LOGGER Unit: EA Qty: 1
Part No. BU-86X •USB cable and software for BM821, BM822, BM827, BM525, BM867 and BM869 •Compatible with Windows 7, Vista and XP
USB INTERFACE KIT FOR BM520/820 SERIES Unit: EA Qty: 1
Part No. BM877 •DMM, true RMS for Installation testing with 50V to 1kV Insulation test and
continuity test •EN61010 CATIII 1000V, CAT IV 600V AC and DC •3 5/6 digit, 6000 count dual display LCD, bargraph, backlight •VFD AC Voltage and BeepJack input warning •Polarisation index (PI) and dielectric absortion ratio (DAR)
INSULATION TESTER &DMM CONTINUTY 50V 1KV Unit: EA Qty: 1
8 cabac.com.au133 122
Part No. T2600 • Open jaw clamp meter for AC with CATIII 600V multimeter functions and a 3 1/2
digit 3999 count LCD • Easy to use with robust construction • Test lead holder for easy use to testing • Data hold, duty cycle and relative zero functions
DIGITAL CLAMP METER OPEN JAW 200A ACBASC AC CLAMP METERSCLAMP METERS
Unit: EA Qty: 1
Part No. BM111M • Compact clamp suitable for working in small distribution boards • Very light-weight • Large display • Multiple functions including capacitance
DIGITAL CLAMP 600A AC COMPACT Unit: EA Qty: 1
Part No. BM127M • Dual display compact clamp suitable for working in small distribution boards • Very light-weight • Dual readings such as voltage and current • Multiple functions including capacitance and temperature
DUAL SCALE CLAMP ON DIGITAL MULTIMETER Unit: EA Qty: 1
Part No. C2950 • 4000 Count 3 1/2 digit LCD • Data hold • Auto ranging and range/feature select • Auto power OFF
CLAMP METER 1000A ACAC QUALITY CLAMP METERS WITH INCREASED FUCTIONS
Unit: EA Qty: 1
Part No. T9001 • Clamp meter AC current up to 600A and NCV detection • CATIV 600V • 3 3/4 digit 4000 count LCD • Relative and data hold • Voltage test: 10 MOhm input impedance
600A AC CURRENT CLAMP Unit: EA Qty: 1
9cabac.com.au 133 122
Part No. BM076 • Compact Clamp 600A ac, true rms, plus EF (NCV), inrush current & phase rotation
testing • CATIII 600V • Min/max/av, data & relative hold • Backlight LCD, 3 5/6 digit, 6000 count LCD • Jaws 30mm cable with AmpTip facility
600A AC TRMS COMPACT CLAMP METER Unit: EA Qty: 1
Part No. TBM116 • True RMS Measurement • 3 3/4 digit 4000 count LCD • Data and relative hold • Large jaw size 45mm • PC interface TBR13X
1000A AC CLAMP TRUE RMS Unit: EA Qty: 1
Part No. BM086 • Clamp 1000A ac, true rms, EF (NCV), plus inrush current and phase rotation
testing • CATIV 600V CATIII 1000V • Min/max/av, data relative hold • Backlight LCD, 3 5/6 digit, 6000 count LCD • Jaws 51mm cable with AmpTip facility
1000A AC TRMS CAT IV COMPACT CLAMP METER Unit: EA Qty: 1
Part No. TBM118 • Clamp meter 2000A AC and DC • 3 3/4 digit 6000 count LCD with backlight • Electric Field (NCV) detection • PC interface kit TBR13X • Large jaw size 45mm
2000A AC CLAMP METER TRUE RMS Unit: EA Qty: 1
Part No. C2010 • 3 1/2 digit 3999 count LCD CATIII 600V true RMS leakage clamp • Measures AC current from mill amperes to 600A • Data hold, continuity, relative and diode check • Auto/manual ranging
LEAKAGE CLAMP METER TO 600ACURRENT CLAMPS WITH SPECIAL FEATURES
Unit: EA Qty: 1
10 cabac.com.au133 122
Part No. BM079 • Clamp meter 600A ac/dc, true rms, EF (NCV), plus inrush current and phase
rotation testing • CATIII 600V, 3 5/6 digit, 6000 • MIn/max/ave, data & peak hold • Backlight LCD, feature packed • Jaws 35mm cable with AmpTip facility
600A AC/DC TRMS COMPACT CLAMP METER Unit: EA Qty: 1
Part No. BM089 • Clamp, 1000A ac/dc, true rms, plus EF (NCV) inrush current and phase rotation
testing • CATIV 600V CATIII 1000V • Min/max/Ave, data and peak hold • Backlight LCD, AmpTip, feature packed • Jaws 51mm cable with AmpTip facility
1000A AC/DC TRMS CAT IV CLAMP METER Unit: EA Qty: 1
Part No. TBM135 • True RMS Measurement with 5400 point recording • 3 3/4 digit 6000 count LCD with backlight • Hi-Lo data logging format with optional software for PC interface • Require Sofware interface kit TBR13X for PC connection. • Large jaw size 45mm
1000A AC CLAMP LOGGER TRUE RMS Unit: EA Qty: 1
Part No. T9005 • Clamp 600A ac/dc,True RMS measurement featuring inrush current mode • CATIV 600V • 4 digit 10,000 count LCD • Relative, data, peak hold and min/max recording • Input impedance: 1MOhm.
TRUE RMS CURRENT CLAMP 600A AC/DCAC/DC CURRENT CLAMPS
Unit: EA Qty: 1
Part No. T9105 • CATIV 600V True RMS measurement featuring inrush current mode • Relative, data, peak hold and min/max recording • 4 digit 10,000 count LCD, CATIV 600V • Inrush current for motors. • Low Input Impedance: 1Mohm
TRUE RMS CURRENT CLAMP 1000A AC/DC Unit: EA Qty: 1
11cabac.com.au 133 122
Part No. BM197 • 3 5/6 digit, 6000 + 1999 counts dual LCD • Dual display AC+Hz and ACV+Hz • CATIV 1000V • Probe contact EF detection
CLAMP METER 2000A AC/DC Unit: EA Qty: 1
Part No. T202 • Clamp adaptor for digital multimeters with 1mV=1A output • Large jaw 57mm • Two range switch 200A or 2000A DC/1500A AC • Auto zero button and hall effect sensor
DIGITAL CLAMP ADAPTOR - 2000A AC/DCCLAMP ADAPTORS
Unit: EA Qty: 1
Part No. BM157 • 1000A True RMS 3-Phase Power Clamp Meter • CAT III 600V • Includes Test lead pair, users manual & soft pouch
1000A TRUE RMS 3-PHASE POWER CLAMP METER Unit: EA Qty: 1
12 cabac.com.au133 122
Part No. T1800 • Featuring low resistance and voltage measurement and supplied with straps to
assist access when testing • Voltage detection live line visual warning light • Handy plastic case with leads compartment • Removable lid
ANALOGUE INSULATION TESTER CATIII 500V
INSULATION METERS
Unit: EA Qty: 1
Part No. T2732 • Low resistance and default voltage measurement • Voltage detection live line visual and audible warning • Robust case protected in rubber boot • Analogue display with ‘parallax error’ mirror
ANALOGUE INSULATION TESTER Unit: EA Qty: 1
Part No. C5201 • 3 1/2 digit 1999 count LCD • Sound and flash alarm • 22mm digital display • Data hold and continuity test
DIGITAL INSULATION TESTER 250/500/1000V Unit: EA Qty: 1
Part No. T2751 • Low resistance and voltage measurement with low Ohms adjustment • Voltage detection live line visual warning light • Selector switch for measuring voltage or insulation resistance • Rugged housing with protective rubber boot
DIGITAL INSULATION TESTER Unit: EA Qty: 1
Part No. C8010 • High Range 200G-Ohm insulation tester with large LCD (78x67), 3 1/2 digits, 2000
count LCD • IEC61010 CAT III 600V. Voltage measurement up 600V • Auto-ranging with 200G-Ohm at 1000V test • Continuity Test at >210 mA • Capacitor test function
DIGITAL INSULATION TESTER Unit: EA Qty: 1
13cabac.com.au 133 122
Part No. MD1000R • Insulation tester, up to 200 giga-ohm, 250V, 500V & 1000V, with guard terminal • Low resistance and continuity measurement • Auto ranging and programmable timer • AC/DC voltmeter up to 600V • Rechargeable NiMH battery
INSULATION TESTER 250/500/1000V 200GOHM Unit: EA Qty: 1
Part No. BM877 • DMM, true RMS for Installation testing with 50V to 1kV Insulation test and
continuity test • EN61010 CATIII 1000V, CAT IV 600V AC and DC • 3 5/6 digit, 6000 count dual display LCD, bargraph, backlight • VFD AC Voltage and BeepJack input warning • Polarisation index (PI) and dielectric absortion ratio (DAR)
INSULATION TESTER &DMM CONTINUTY 50V 1KV Unit: EA Qty: 1
Part No. MD5060 • Insulation tester 5kV 5 tera-ohm, auto ranging with digital display and bar graph • Dielectric Absorption Index (DAI), Polarization Index (PI) • Step test voltage and chronometer up to 90 min • Real time clock and calendar • USB interface and built in printer
INSULATION TESTER 5KV-5KV 5TOHM Unit: EA Qty: 1
Part No. TIN7D • High voltage up to 500v to 10kV digital insulation tester with PI and DAR • Suitable for low capacitance equipment such as switch boards • Live Circuit Warning and Auto Discharge • Auto DAR and PI calculation with time duration • Heavy duty case
INSULATION TESTER 1KV TO 10KV Unit: EA Qty: 1
Part No. MD10kVR • 10kV insulation tester up to 10Tera Ohms with chronometer, AC/DC voltmeter and
printer • Automated PI and DAR. Anndroid device connection • Built memory for logging • Real time clock and calendar • Rechargable LiFePO4 battery
INSULATION TESTER DIGITAL 10KV 10TOHM Unit: EA Qty: 1
14 cabac.com.au133 122
Part No. T2726 • Loop impedance analyser with LED mains polarity supply indication and PSC • Simple one test button action when LED correct • Single phase electrical network tester • Test output about 15A pulses. Requires RCD wiring bypass • Tests loops active/neutral, active/earth, neutral/earth
LOOP IMPEDENCE AND PSC Unit: EA Qty: 1
Part No. T2712EL • Residual Current Device (RCD) or ELCB trip time tester with LED indication for
power, battery and mains polarity • Simply select earth leakage resistance test value • Displays adjustment percentage for high and low voltage • Suitable for 10A and 30 mA RCDs • CAT III 300V
DIGITAL RCD TESTER - 240V Unit: EA Qty: 1
Part No. TEL11 • Three phase trip time and trip current RCD (ELCB) tester with robust, impact
resistant housing and removable lid • Tests single and three phase RCDs • Operating voltage 100V to 500V • Selection of phase angle 0 or 180 degrees
THREE PHASE RCD TESTER Unit: EA Qty: 1
Part No. T2720 • Earth resistance tester for two or three electrodes • 3 1/2 digit 1999 count LCD • Measures earth voltage to 200V • Includes electrodes, long leads and simple push button operation • Spare lead set: AL36RYGKIT
DIGITAL 3 WIRE EARTH TESTER Unit: EA Qty: 1
Part No. C4235 • Multifunction LCM display • CATIV 300V • Tests earth resistivity and earth resistance • 2, 3 and 4 wire testing
EARTH RESISTANCE TESTER Unit: EA Qty: 1
15cabac.com.au 133 122
Part No. INSTALTESTKIT • Complete, compact installation kit with ability to test according to AS/NZS 3000 • IEC61010 CATIII 600V, CATIV 300V • Multifunction 128 x 64 dot matrix LCD
MI3125 INSTALLATION TEST KIT AS/NZ3000 Unit: EA Qty: 1
Part No. INSTALTESTKITB • Complete, compact installation kit with ability to test according to AS/NZS 3000 • Includes sofware option for logging and records • Multifunction 128 x 64 dot matrix LCD • IEC61010 CATIII 600V, CATIV 300V • Kit includes MI3125 and accessories
MI-3125B INSTEST KIT INCL. SOFTWARE Unit: Qty:
16 cabac.com.au133 122
Part No. WIBRETEST • CATIV 300V voltage tester, solenoid type 125V up to 750V AC and 110V to 750V
DC • Rubber handles and tough probe housing • Suitable for 240V single phase and 415V three phase voltage tests • Light indication for ‘live’ and AC or DC • Solenoid indicator drains low energy signals
VIBRATING VOLTAGE AND LINE TESTER CATIVVOLTAGE TESTERS
Unit: EA Qty: 1
Part No. BT-71EU • Voltage tester AC & DC with LED voltage and polarity indication plus EF (NCV)
Tester • Made to EN61010 CATIV 600V & EN61243-3 • Optional plugable test lead available up to 3m long • Test probes 4 & 2 mm diameter for various applications • Audible continuity test
1000V LED VOLTAGE TESTER Unit: EA Qty: 1
Part No. C3031 • LED and LCD displays • CATIV 600V • Voltage to 690V AC/DC
DIGITAL VOLTAGE TESTER CATIV 600V Unit: EA Qty: 1
Part No. BT-73EU • Voltage tester AC & DC with LED/LCD voltage, polarity & phase rotation indication
plus EF Tester & RCD trip test • Made to EN61010 CATIV 600V & EN61243-3 • Optional plugable test lead available up to 3m long • Test probes 4 & 2 mm diameter for various applications • True RMS measurement & Audible continuity test
1000V LCD + LED VOLTAGE TESTER Unit: EA Qty: 1
Part No. T2600 • Open jaw clamp meter for AC with CATIII 600V multimeter functions and a 3 1/2
digit 3999 count LCD • Easy to use with robust construction • Test lead holder for easy use to testing • Data hold, duty cycle and relative zero functions
DIGITAL CLAMP METER OPEN JAW 200A AC Unit: EA Qty: 1
17cabac.com.au 133 122
Part No. BM039F • 200ac 12mm slip open jaw clamp DMM, True RMS, with backlight and EF (NCV)
detection • 3 5/6 digit 6000 count LCD, Crest/Data Hold • 600V, 6MOhm, 2.5mF, 999.9Hz with LPF • EF Bargraph, Temperature, DC micro Amps • CAT III 600V, CAT IV 300V
OPEN JAW 200A AC CLAMP METER Unit: EA Qty: 1
Part No. ACTEST3 • Neon light indicator lamp style test screwdriver • GS/TUV and CE approvals • Featuring an insulated shaft • 3.5mm driver tip width and 190 mm long • Weight: 27g
AC TEST SCREWDRIVER 3.5 X 190MMVOLTFINGER (TEST PENS)
Unit: EA Qty: 1
Part No. T7107A • CATIV 1000V non-contact voltage detector with optional belt pouch available,
suitable for tracing live” wires and conductors” • Voltage range 50-1000V • Variable tone buzzer to indicate voltage intensity • Audible and bright LED voltage indication • Spare pouch & clip - VPOUCH & T7107A-CLIP
VOLTAGE DETECTOR CATIV 1000V Unit: EA Qty: 1
Part No. C8902A • CATIII 600V voltage proximity sensor with adjustable sensitivity for polarity testing • Visual and audible indication • On/Off button • Double moulded
AC VOLTAGE (NCV) DETECTOR ADJ CATIII 600 Unit: EA Qty: 1
Part No. C3121 • LED visual and audible Non-Contact Voltage (NCFor EF) indication • LED torch next to test point • ON/OFF switch and sensitivity buttons • Ideal for tracing and locating live” conductors” • CATIV 1000V
VOLTFINGER WITH TORCH NON CONTACT Unit: EA Qty: 1
18 cabac.com.au133 122
Part No. C6818 • LCD displays digital readout and bargraphs and includes a NCV Detector • CATIII 300V for both receiver and transmitter • Suitable for any conductor tracing • Three strength level options in transmitter
CIRCUIT CABLE TRACERCABLE TRACER
Unit: EA Qty: 1
Part No. T606 • Digital phase rotation tester with ‘live’ line and two way rotation indication • Plug in standard instrument test leads • IEC61010 CATIII 500V • No moving mechanical parts, compact and light
PHASE ROTATION TESTERPHASE SEQUENCE (ROTATIO) TESTER
Unit: EA Qty: 1
Part No. T860 • Phase and motor rotation tester • CATIII 500V • Separate circuits for testing phase and motor rotation • Bright neon light indication and plug in leads
PHASE AND MOTOR ROTATION MTR CATIII 500V Unit: EA Qty: 1
Part No. C895 • Phase sequence indicator with non-contact probes CATIV 600V and CATIII 1000V • Indicates phase voltage (75V to 1000V AC) • Bright LED for outdoor indication • Test lead length 1.5m for overhead lines • Use for phase voltage 70V to 1000V
PHASE ROTATION TESTER NON-CONTACT CATIV Unit: EA Qty: 1
Part No. TEL1TLV2 • Socket polarity visual tester indication • Suitable for 230V 10A Australian socket outlets • RCD trip tester with push button • RCD trip tester with push button • Indicates Active polarity compared to neutral/earth
POWER POINT TESTER V2SOCKET TESTERS
Unit: EA Qty: 1
19cabac.com.au 133 122
Part No. R158003 • Voice, Data and Video Cable Verifier for testing data cabling, telephone wiring and
video/security cabling • All the features of the VDV II Plus model # R158002 plus: • PoE detection with voltage information • Media Service detection such as ISDN, PBX and PoE • Comes in a carry case with multiple test adaptors and leads
VDV II PRO CABLE VERIFIERIDEAL LAN TESTERS
Unit: EA Qty: 1
Part No. 35RJTST8 • Primary use is for testing continuity, shorts and open circuits, individual cables and
pairs of UTP or STP • Remote display unit allows for viewing at either end • Displays pairs and crossed pairs • Includes LEDs for each wire ensuring easy pin configuration
LAN TESTER 10BASET 10BASE2 BNC/RJLAN TESTERS
Unit: EA Qty: 1
Part No. 256655 • An ideal tool for network installers and trouble shooters working on small LANs • Ideal for testing switches and NIC cards • Auto-negotiation function tests the LAN devices speed up to 100MB • Port-finder function sends signal to switch to identify the port
NETWORK DIAGNOSTIC TOOL Unit: EA Qty: 1
Part No. WL-F601 • Provides specific information about each network when there are multiple
networks • Provides channel information (1 to 13) • Shows signal availability 802.11b and 802.11g • Detects encryption (WEP and WPA) range 60m
DIGITAL HOTSPOTTERWIFI TESTERS
Unit: EA Qty: 1
20 cabac.com.au133 122
Features
ACTEST3 T7107A C8902A C3121
Screwdriver Touch Tester NCV Adjustable NCV NCV/ Torch
Audible NCV √ √ √
Visual NCV √ √ √ √
Vibration Detect
AC/DC AC AC AC AC
NCV Detect √ √ √
Magnetic Field Indication
Torch Light LED
Special FeaturesDetects
Energised Solenoids
CATIII 300V 1000V 600V 1000V
CATIV - 1000V 300V 1000V
Warranty 1 1 1 1
SC
RE
WD
RIV
ER
VO
LT F
ING
ER
S -
EF
OR
NO
N C
ON
TAC
T V
OLT
AG
E D
ETE
CTO
RS
(NC
V)
Voltage Detectors and Testers
Features
WIBRETEST BT-71EU BT-73EU C3031
Voltage Tester LED Voltage Continuity. RCD trip
LED/LCD Voltage Continuity. RCD trip
LED/LCD/ Voltage/ Continuity/ Phase
Rot.
Audible NCV √ √ √
Visual NCV √ √ √ √
Vibration Detect √
AC/DC AC/DC AC/DC AC/DC AC/DC
NCV Detect √ √
Magnetic Field Indication
Torch Light √ LED
LCD Backlight √
Continuity √ √ √
LED Scale √ √ √
LCD √ √
Phase Rotation √ √
Special Features Single PoleSelf Test, Single Pole,
EF, Optional Long Lead
Self Test, Single Pole, EF, RCD Trip, True
RMS, Optional Long Lead
Single Pole
CATIII 600V 1000V 1000V 1000V
CATIV 300V 600V 600V 600V
Warranty 1 1 1 1
VO
LTA
GE
TE
STE
RS
Voltage Detectors and Testers - Selection Chart
Voltage Testers - Selection Chart
21cabac.com.au 133 122
Mul
timet
ers
- Sel
ectio
n C
hart
Multem
eters
FEAT
UR
ESC
505
T821
1DT8
221C
TBM
22TB
M27
C18
7T8
268
T822
9TB
M68
5B
M25
1B
M25
7TB
M80
5TB
M80
7B
M31
9B
M82
1B
M82
2B
M82
7B
M87
7B
M52
5B
M86
7B
M86
9
Dis
play
Ana
log
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
Dig
ital
LCD
cou
nts
1999
1 99
94
000
6 00
040
003
999
3 99
96
000
6 00
060
004
000
4 00
060
0010
000
1000
010
000
6000
1000
050
000
50 0
00
LCD
dig
its3
½3
½3
¾3
5 ⁄63
1 ⁄23
3 ⁄43
3 ⁄43
5 ⁄65
5 ⁄65
5/6
3 3 ⁄4
3 3 ⁄4
3 5 ⁄6
3 5 ⁄6
3 5 ⁄6
3 5 ⁄6
3 5 ⁄6
3 5 ⁄6
4 4 ⁄5
4 4 ⁄5
Bar
grap
h√
√√
√√
√√
√√
√√
Bat
tery
Tes
t√
√√
√√
√√
√√
√√
√√
√√
√√
√√
Max
AC
Vol
tage
1000
600
600
600
600
7075
075
010
0010
0010
0010
0010
0010
0010
0010
0010
0010
0010
0010
0010
00
Max
DC
Vol
tage
1000
600
600
600
600
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
Max
AC
Cur
rent
(A)
1010
2 m
A10
1010
1010
1010
1010
1010
1010
10
Max
DC
Cur
rent
(A)
1010
2 m
A10
1010
1010
1010
1010
1010
1010
10
Fuse
d R
ange
200m
A10
10√
√√
√√
√√
√√
√√
√
Max
Res
ista
nce
20M
20M
20M
40M
6M40
M20
0M40
M6M
60M
60M
40M
40M
60M
60M
60M
60M
60M
(25G
)60
M50
M50
M
Con
tinui
ty B
eepe
r√
√√
√√
√√
√√
√√
√√
√√
√√
√√
√
Dio
de T
est
√√
√√
√√
√√
√√
√√
√√
√√
√√
√√
√
Aut
oran
ging
√
√√
√√
√√
√√
√√
√√
√√
√√
√√
√
Freq
uenc
y (H
z)20
k10
0k10
0K1-
50k
1M1k
1k1k
1k10
- 100
k1k
200k
200k
Cap
acita
nce
µF20
020
0020
0020
020
020
0030
0030
0030
0020
0025
m25
m25
m30
m25
m25
m25
m
Tem
pera
ture
°C-2
0 to
100
0-2
0 to
100
0-5
0 to
100
0-5
0 to
100
0-5
0 to
998
-50
to 9
99-5
0 to
100
0
Min
/Max
Hol
dm
axm
ax√
√m
axm
ax√
√√
√√
Dat
a H
old
√√
√√
√√
√√
√√
√√
√√
√√
√√
Cre
st o
r Pea
k H
old
√√
√√
True
RM
S M
easu
rem
ent
√√
√√
√√
√√
Bac
k Li
ght
√√
√√
√√
√√
√√
√√
√
Spla
sh &
Dus
t Pro
of√
√√
√√
√√
√√
√√
√√
√√
Tran
sien
t Pro
of6k
V6k
V6k
V4k
V4k
V6k
V6k
V12
kV6k
V6.
5kV
6kV
6kV
6kV
12kV
12kV
12kV
8kV
12kV
12kV
12kV
Rel
ativ
e R
efer
ence
√√
√√
√√
√√
√√
√√
Hol
ster
√√
√√
√√
√√
√√
√√
√√
Aut
o Po
wer
Off
√√
√√
√√
√√
√√
√√
√√
√√
√√
√√
Fire
Ret
ard
Cas
e√
√√
√√
√√
√√
√√
√√
√√
PC C
omm
s.U
SB
US
BU
SB
US
BU
SB
US
BU
SB
US
B
Dat
a lo
gger
√
Oth
er F
eatu
res
Taut
Ban
d m
ovem
ent.
Mirr
or
Com
pact
pe
n ty
pehf
e 1-
1001
LAN
C
able
Te
ster
.R
J45,
R
J11
Inco
rrec
t S
ocke
t Ale
rt
Dua
l D
ispl
ay,
RH
%,
Lux,
dB
, In
corr
ect
Soc
ket
Ale
rt
EF
EF
Logi
c Le
vel
Hz,
E
F
Dw
ell
Ang
le,
RP
M,
ms-
Fuel
In
ject
ion
dete
ctor
, S
elec
tabl
e
Dua
l D
ispl
ay,
Bee
pJac
k
Dua
l D
ispl
ay,
Bee
pJac
k
Dua
l D
ispl
ay,
Bee
pJac
k,
EF,
Log
ic
Leve
l Hz,
E
F
Dua
l D
ispl
ay,
Bee
pJac
k,
Insu
latio
n Te
st,
PI
& D
AR
, C
ontin
uity
Te
st,
Dua
l D
ispl
ay,
Bee
pJac
k,
Logg
ing
Mem
ory,
D
ual T
1-T2
Dua
l D
ispl
ay,
%4-
20m
A,
dBm
, B
eepJ
ack
Dua
l D
ispl
ay,
%4-
20m
A,
dBm
, VFD
, B
eepJ
ack,
D
ual T
1-T2
CAT
III
600
600V
600V
300V
300V
600V
600V
600
V10
00V
600V
600V
600V
600V
CAT
III
600V
>100
0V>1
000V
>100
0V10
00V
>100
0V>1
000V
>100
0V
CAT
IV30
0V30
0V15
0V15
0V30
0V30
0V30
0V10
00V
300V
300V
300V
300V
CAT
IV
300V
1000
V10
00V
1000
V60
0V10
00V
1000
V10
00V
War
rant
y (y
ears
)1
11
11
11
1L.
O.P
.L.
O.P
.L.
O.P
.1
11
L.O
.P.
L.O
.P.
L.O
.P.
L.O
.P.
L.O
.P.
L.O
.P.
L.O
.P.
22 cabac.com.au133 122
Clamp Meters - Selection ChartClamp meters
FEATURES T2600 BM039F BM111M BM127M C2010 C2950 T9001 BM076 TBM116 TBM135 BM086
Jaw Size 12 12.5 26 28 31x40 35 42 30 45 45 51
Display Digital Digital Digital Digital Digital Digital Digital Digital Digital Digital Digital
LCD Display Counts 3999 6000 4000 4000 4000 4000 4000 6000 4000 4000 6000
LCD Display Digits 3 ¾ 3 ⅚ 3 ¾ 3 ¾ 3½ 3 ¾ 3 ¾ 3 ⅚ 3 ¾ 3 ¾ 3 ⅚
Backlight √ √ √ √ √ √ √ √
Bargraph √
AC Current 200 200 600 400 600 1000 600 600 1000 1000 1000
DC Current
AC Voltage 700 600 600 600 600 600 600 600 600 600 1000
DC Voltage 1000 600 600 600 600 1000 600 600 600 600 1000
Auto Ranging √ √ √ √ √ √ √ √ √ √ √
Relative Zero √ √ √ √ √
APO √ √ √ √ √ √ √ √ √ √ √
Resistance (Ω) 40M 6M 40M 40M 20M 40M 40M 60k 40M 1k 60k
Continuity Buzzer √ √ √ √ √ √ √ √ √ √
Frequency (Hz) 100k 1K 50k 50k 100k 5M 5-400k 500 5-400k
Capacitance (µF) 4 2500 3000 4000 200µ 100 2500 2500
Temperature °C -40 to 400 -20 to 300 20 to 1000 -40 to 400 -50 to 300 -40 to 400
True RMS √ √ √ √ √
Diode Test √ √ √ √ √ √ √ √
Peak Hold √
Data Hold √ √ √ √ √ √ √ √ √ √
Min/Max Recording √ Max Max √ √ √
Special Features LPF for VFD V-fundamentals Dual Display Leakage, Low
Pass Filter
Flashlight. 10A Splitter with x1
& x10EF (NCV)
EF (NCV), Inrush I,
AmpTip, Phase Rotation, DC
µA
Comms
Current Logger, HDT%-R, Serial PC Comms
EF (NCV), Inrush I,
AmpTip, Phase Rotation, DC
µA
CAT II 600V
CAT III 600V 600V 600V 600V 600 - 1000V 600 600V 600V 1000
CAT IV 300V 300V 300V 300V 300 - 600V 300 300V 300V 600
Warranty Years 1 1 1 1 1 1 1 1 1 1 1
FEATURES TBM118 C2108 T9005 BM079 T9105 BM089 BM197 BM157 T202 TA3000
Jaw Size 45 26 42 35 34x65 51 55 45 57 194
Display Digital Digital Digital Digital Digital Digital Digital Digital Adaptor Adaptor
LCD Display Counts 6000 6600 10000 6000 10000 6000 6000 +1999 6000/9999
LCD Display Digits 3 ⅚ 3 ⅚ 4 3 ⅚ 4 3 ⅚ 3 ⅚ 3 ⅚
Backlight √ √ √ √ √ √ √
Bargraph √ √
AC Current 2000 660 600 600 1000 1000 2000 1000 1500 3000
DC Current 660 400 600 600 1000 2000 2000
AC Voltage 600 660 600 600 600 1000 1000 600
DC Voltage 600 660 600 600 600 1000 1000 600
Auto Ranging √ √ √ √ √ √ √ √
Reletive Zero √ √ √ √ √ √
APO √ √ √ √ √ √ √
Resistance (Ω) 6M 6M 40M 60k 40M 60k 40M
Continuity Buzzer √ √ √ √ √ √ √ √
Frequency (Hz) 50k 10k 400 5-400k 400 5-400k 400Hz
Capacitance (µF) 2000 66m 999.9 2500 999.9 2500 2000
Temperature °C -40 to 1200 -40 to 400 -40 to 1200 -40 to 400 -50 to 1000-50 to 300
True RMS √ √ √ √ √ √ √ √
Diode Test √ √ √ √ √ √ √ √
Peak Hold √ √ √ √
Data Hold √ √ √ √ √ √ √ √
Min/Max Recording √ √ √ √ max
Special Features Comms, EF (NCV) Clamp Light 1MΩ Imput
Impedance
EF (NCV), Inrush I, AmpTip, Phase Rotation, DC µA
EF (NCV), Inrush I, AmpTip, Phase Rotation, DC µA
Autocheck, VFD-V, VFD-A, Inrush, EF, PC
Interface
kVA, W, THD%, Serial PC
Comms, Cosϕ
CAT II
CAT III 600V 600V 1000V 600 1000V 1000 1000 600 600 600
CAT IV 300V 300V 600V 300 600V 600 1000 300 300 300
Warranty Years 1 1 1 1 1 1 1 1 1 1
23cabac.com.au 133 122
Insu
latio
n Te
ster
s - C
ompa
rison
Cha
rtIn
sula
tion
test
ers
FEAT
UR
ES
INSULATION TESTERS
T180
0T2
732
T275
1B
M87
7C
8010
C52
01M
D10
00R
TIN
6AM
D50
60TI
N7D
MD
10K
VR
INSTALLATION TESTERS
INST
ALT
ESTK
ITIN
STA
LTES
TKIT
BD
ispl
ayA
nalo
gue
Ana
logu
eD
igita
lD
MM
Dig
ital
Dig
ital
Dig
ital
Ana
logu
eD
igita
lD
igita
lD
igita
lD
igita
lD
igita
l
50 V
Tes
t Vol
tage
√√
√
100
V T
est V
olta
ge√
√√
√
250
V T
est V
olta
ge√
√√
√√
√√
√√
500
V T
est V
olta
ge√
√√
√√
√√
√√
√√
√
1000
V T
est V
olta
ge√
√√
√√
√√
√√
√√
√
2500
V T
est v
olta
ge√
√√
5000
V T
est V
olta
ge√
√√
√
1000
0 V
Tes
t Vol
tage
√√
√
Hig
h R
esis
tanc
e R
ange
0-
400
MΩ
500
k
-400
MΩ
20, 2
00 &
20
00 M
Ω0.
02 to
25
GΩ
0 to
200
GΩ
10
00V
2GΩ
at
1000
V1
to 2
00
GW
100
0V<4
00G
Ω &
<
400
GΩ
5 TΩ
800k
Ω
- 500
GΩ
10 T
Ω<
19 M
Ω, 2
0- 9
9MΩ
&
100-
199M
Ω<
19 M
Ω, 2
0- 9
9MΩ
&
100-
199M
Ω
Insu
latio
n Te
st C
urre
nt2
mA
1.3
mA
1 m
A1m
A1m
A1m
A1.
5 m
A1.
5 m
A1.
5mA
Varia
ble
2mA
1 m
A1
mA
Con
tinui
ty T
est C
urre
nt24
0 m
A20
5 m
A21
0mA
110m
A-2
0Ω
210m
A-2
Ω>2
10m
A20
0mA
>200
mA
--
--
200m
A20
0mA
Low
Res
ista
nce
0-50
&
Infin
ity0-
3, &
500
0-20
/
0-2
00/
0-20
000.
015
to
21.9
9Ω0
to 2
0MΩ
0 to
200
Ω-
--
-0
- 199
9Ω0
- 199
9Ω
Tim
er (C
ontin
uous
Tes
t)√
√√
√√
√√
√
Live
Circ
uit W
arni
ng√
√√
√√
√√
Aut
omat
ed O
pera
tion
√√
√√
√√
√√
Aut
o D
isch
arge
√√
√√
√√
√√
√√
√√
Res
ista
nce
Buz
zer
√√
√√
Volta
ge M
easu
rem
ent
0-60
0 VA
CD
efau
lt
0-60
0 VA
C
Def
ault
0-
600
VAC
1000
V A
C/
DC
, VFD
-V
600V
600V
AC
/DC
700V
AC
, 10
00V
DC
600V
A
C/D
C-
--
1000
V55
0V A
C55
0V A
C
Bat
tery
Che
ck√
√√
√√
AC
/DC
√√
AP
O√
√√
√√
√√
√√
√√
Mem
ory/
Dat
a S
tora
ge√
√√
√
PC
Com
ms
√√
US
B
Spe
cial
Fun
ctio
ns
0-3Ω
R
ange
, D
efau
lt Vo
ltage
Te
st
Dua
l Rea
ding
D
ispl
ay,
VFD
-F,
VFD
-Hz,
PI,
DA
R, T
rue
RM
S.
1000
V
Insu
latio
n Te
st
Up
to 2
00G
Ω
Gua
rd
Term
inal
, re
char
gebl
e ba
tterie
s,
DA
R, P
I, P
ass/
Fail,
Tr
ue R
MS
1 W
Out
put
DA
R &
PI,
Mem
ory,
PC
tra
nfer
US
B,
Prin
ter,
Gua
rd,
rech
arge
able
Li
FeP
O4
Bat
terie
s
1W o
utpu
t, D
AR
, PI,
Tim
er,
Ene
rsav
eTM
DA
R &
PI,
Mem
ory,
P
C tr
anfe
r U
SB
, Prin
ter,
Gua
rd,
rech
arge
able
Li
FeP
O4
Bat
terie
s,
IP54
, GP
S
Loop
Impe
danc
e,
PS
C,
RC
D, S
ocke
t, B
ackl
ight
, P
olar
ity,
Pha
se R
otat
ion
Loop
Impe
danc
e, P
SC
, R
CD
, Soc
ket,
back
light
, P
olar
ity, P
hase
Rot
atio
n,
Sof
war
e &
PC
link
.
IEC
6101
0 R
atin
g (C
AT II
I)60
0V60
0V60
0V10
0060
060
060
0V60
0V30
0V60
060
0V60
0V
IEC
6101
0 R
atin
g (C
AT IV
)30
0V30
0V30
0V60
030
030
060
0V30
0V15
0V30
0V30
0V
War
rant
y (y
ears
)1
22
L.O
.P.
11
11
11
11
1
Not
e A
S/N
ZS61
010
Rat
ing
is re
quire
d fo
r vol
tage
mea
sure
men
t, no
t ins
ulat
ion
test
ing.
24 cabac.com.au133 122
LEADS - VERSION 2
Part No. AL01 AL02 AL04 AL24 AL28-1 AL28-3 AL28-5 AL30RBGKIT AL30RWBKIT
Description 1kV 10A Black Single Lead
1kV 10A Black Single Set +
Croc-Clip
1kV 10A DMM Set
PVC, Set Threaded Pins
1kV 10A DMM Set
1kV 10A 4mm Probe
1kV 10A Threaded set +
Croc Clips
Set L, N & E with Croc-Clips
Set L1, L2 7 L3 with Croc-Clips
Lead Length (m) 3 0.9 0.84 1
Probe Φ (mm) 2 2 Threaded 2 4 2 Threaded 4
Instrument Plug 90o 4mm shrouded
Colours Black Red & Black
Set of: 1 2
Accessories - Small Croc-Clips - Small
Croc-Clips Large Croc-Clips
CAT III 1000V
CAT IV 1000V
Part No. AL04RBY TEL-EL TEL-AN AL35L AL37B AL37R AL38C AL52F AL57F10A AL36RYGKIT AL-4WER
DescriptionTest Lead Set RD/BK/YL with
Croc-Lips
RCD test 10A Plug and Lead
RCD test 10A Plug and Lead
No Neutral
Silicone Insulated Lead Set
Stacking Lead Black
Stacking Lead Red
Croc-Clips for 4mm Banana Probes
Fused Leads Set 2A CAT IV
Fused Lead Set 10A CAT IV
Test Lead Set for Earth Resistance
Tosters
Earth Resistance
Leads for 4-Wire
Testers
Lead Length (m) 1 0.5 1 0.5 N/A 1
Green - 5m Yellow - 10mRed - 15m
Red - 36m Spike 45cmBlack- 3m Blue - 20m
Green - 50mProbe
Φ (mm) 2 10A Plug 10A Plug Croc-Clips
Instrument Plug
90o 4mm shrouded Shrouded 4mm Straight 90o 4mm
shrouded
Straight 4mm
shrouded piggy back
Straight 4mm
shrouded piggy back
90o 4mm shrouded
Colours Red, Black, Yellow
Red, Green & Black
Red & Green Red & Black Black Red Red & Black Red, Green,
Yellow
Black, Blue, Green,
Red + Spikes
Set of: 3 1 2 1 2 3 4
Accessories 2x Croc Clips 10A Plug Optional - Croc-Clips Optional Croc-Clips -
CAT III 1000V 600V 1000V 600V 690V 2A 1000V 10A 600 2A -
CAT IV 1000V - 600V 300V 690V 2A 600V 10A - -
Leads - Comparison Chart
25cabac.com.au 133 122
Notes:
In support of our policy of continuous product improvement we reserve the right to change materials and specifications without notice. Drawings, where shown, may not be to scale. Dimensions are metric and size maybe approximate. Where possible data sheets including MSDS are made available on our website and APPs. All products should be installed and used in accordance to manufacturer’s instruction provided. Warning: products may be subject of registered designs and patents. Refer to our website or APPs for terms and conditions on warranty. Every effort has been made to ensure accuracy of content. However no liability will be met by CABAC or its suppliers for any errors or omissions. Product data and information is no binding. All brands and logos are registered trademarks and are subject to copyright laws. No part of this catalogue can be reproduced without the consent of CABAC. The ‘One Call, One Day, One Delivery’ does not cover the following items: Cast Resin Kits, Custom Manufacturing & Kitting, Cabinets, Ladders, Pits & Pillars, CABTRAY, TRIPAC and Branch Stock Orders.
CABAC
133 122 | CABAC.COM.AU