Top Banner
Integrated HVAC Controls for Residential Applications Optimize Comfort & Efficiency Compact System Controls Simple Two-Wire Thermostats Energy Saving Features Control Systems
8

tekmar House Control Systems · tekmar has 25 years of experience controlling hydronic heating systems. With reliable, cost effective controls that are easy to install and program,

Oct 17, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: tekmar House Control Systems · tekmar has 25 years of experience controlling hydronic heating systems. With reliable, cost effective controls that are easy to install and program,

Integrated HVAC Controls for Residential Applications

Optimize Comfort & Effi ciencyCompact System ControlsSimple Two-Wire ThermostatsEnergy Saving Features

••••

Control Systems

Page 2: tekmar House Control Systems · tekmar has 25 years of experience controlling hydronic heating systems. With reliable, cost effective controls that are easy to install and program,

Outdoor Sensorenables the system control to anticipate heating requirements for the building.

Cooling Groupsprovide a heat /cool interlock between thermostats.

tekmarNet® Thermostatscommunicate with the House Control to improve comfort through Indoor Feedback.

© 2009 P 523 - 07/09 2 of 8

An Integrated

Page 3: tekmar House Control Systems · tekmar has 25 years of experience controlling hydronic heating systems. With reliable, cost effective controls that are easy to install and program,

tekmarNet® House Controls coordinate all devices in a tekmarNet®

system to provide a level of energy savings, comfort and convenience not

possible with stand-alone controls.

Simple Schedules can be entered into a single Timer 033 and used by the entire system.

One-Touch Adjustmentof every tekmarNet® Thermostat is made possible with a User Switch 479.

3 of 8 © 2009 P 523 - 07/09

Approach to HVAC ControlThe Benefi ts of Two-Way Communication

Page 4: tekmar House Control Systems · tekmar has 25 years of experience controlling hydronic heating systems. With reliable, cost effective controls that are easy to install and program,

Complete System Control

FeaturesModulating or On/Off BoilerUp to 2 Water Temperatures plus DHWSupport for Multiple Types of MixingEasy Zone Wiring at Remote ManifoldsDHW & Setpoint PriorityCooling, Space Heating & Floor Warming on a ScheduleWarm Weather Shut Down

••••••

The tekmarNet® House Control product line is designed to bring the benefi ts of communication to even the

simplest radiant heating system. With innovative features like Indoor Feedback, Zone Synchronization and

Zone Post Purge, the House Control provides complete system control in the most effi cient method possible.

© 2009 P 523 - 06/09 4 of 8

Page 5: tekmar House Control Systems · tekmar has 25 years of experience controlling hydronic heating systems. With reliable, cost effective controls that are easy to install and program,

hr

Saving

Energy Savings & Comfort

One Control, All the Benefi ts ENERGY SAVING FEATURES

Zone SynchronizationEvery tekmarNet® Thermostat communicates to agree on a common, or ‘synchronized’, start time. The result is a boiler that runs more efficiently and cycles less.

Zone Post PurgeAt the end of a cycle, the zones are held on while the boiler is off. This moves residual heat out of the boiler and into the zones where it belongs.

Automatic Boiler DifferentialAutomatically adjusting the boiler differential to changing conditions ensures longer running times and reduced boiler short cycling.

CONVENIENT FUNCTIONALITY

Simple ProgrammingPre-programmed to suit most applications, setting up a House Control System is almost too easy. And with Access level adjustment, the control will stay as you left it.

$aving IndicatorA ‘$aving’ icon displays on screen when the House Control is using any of its many energy saving features.

MonitoringThe House Control monitors everything from pump run times to outdoor temperature extremes to boiler usage, then organizes it in a simple menu for access at any time.

5 of 8 © 2009 P 523 - 06/09

Outdoor Reset with Indoor FeedbackTraditional outdoor reset saves energy by adjusting the supply water temperature to match changing outdoor conditions. This allows the system to operate at a reduced temperature for much of the year, anticipating interior load changes before they occur.

tekmarNet® House Controls take outdoor reset one step further with ‘Indoor Feedback’. tekmarNet® Thermostats communicate with the House Control, allowing it to fi ne-tune supply water temperatures based on actual interior heat gains or losses. The end result? An integrated HVAC system providing unmatched occupant comfort and unparalleled system effi ciency. Remarkably, Indoor Feedback is just one of the House Control’s many exciting features.

Page 6: tekmar House Control Systems · tekmar has 25 years of experience controlling hydronic heating systems. With reliable, cost effective controls that are easy to install and program,

With tN2 Thermostats you can use existing 2 conductor, 18 AWG wire to replace old thermostats with models that offer the energy savings, comfort and convenience your customers want.

tN2 Thermostats

527 One Stage HeatTwo Button

­­

530 One Stage Heat, One Stage Cool & Fan

­

528 One Stage HeatFloor Sensing

­­

Simple Digital InterfaceDual Temperature DisplayShared Setback SchedulesNon-Polarity Sensitive Wiring

••••

tN2 Wiring CentersExpand zone capacity and simplify wiring with tN2 Wiring Centers. Their compact size allows for installation at remote manifolds or in the mechanical room.

Up to Four Zone Valves­ Up to Four Zone Pumps­314 313

Accessories

Two or Four Events5-1-1, 5-2, 7 Day or 24 hr Schedule

••

tN4 Timer 033With up to four unique setback schedules for use by tekmarNet® Controls & Thermostats, the Timer 033 makes saving energy easy.

tN4 User Switch 479A single push of a button on a tekmarNet®

User Switch can change the heating & cooling settings for the entire tekmarNet® system.

Switch between Occupied, Unoccupied & Away

Four On-Board Zones (Expandable to 24 zones per water temperature)Single On/Off or Modulating BoilerDHW ControlUses Two Wire tN2 ThermostatsLarge LCD Display, Simple 4-Button Navigation

••••

tN2 House ControlsSingle Water Temperature (Boiler)4 Zone Valves

­­

400

Two Water Temperatures (Boil + Mix)4 Zone ValvesMixing via Variable Speed Pump or Floating Action Mixing Valve

­­­

402

tN2 House Controls provide fully coordinated system control in a compact enclosure.

Single Water Temperature (Boiler)4 Zone Pumps

­­

401

One Stage HeatSingle Relay

••

tN4 Setpoint Control 161Easily integrate setpoint loads with the heating system. Schedule or enable each setpoint load using tekmarNet®.

Brass Mixing Valves 710-724Three or Four Way brass mixing valves are available in standard pipe sizes and work with the Actuating Motor 741.

Actuating Motor 741An easy way to add mixing to tekmarNet® systems.

Transformer Kit 009K40 VA, 24 V Transformer with 4 x 4” electrical box and fuse.

© 2009 P 523 - 07/09 6 of 8

Page 7: tekmar House Control Systems · tekmar has 25 years of experience controlling hydronic heating systems. With reliable, cost effective controls that are easy to install and program,

8 of 16 © 2009 P 523 - 01/09

tekmarNet® Thermostats 527 528 5302 Wire / tekmarNet®2 •• •• ••Heat Stages 1 1 1Cool Stages - - 1Fan Stages - - 1Auxiliary Sensor Inputs - 1 -Aux Outdoor Sensor - •• OR

-Aux Floor Sensor - •• -HeatingFloor Warming - •• -Zone Synchronization •• •• ••Zone Post Purge •• •• ••Auto Heating Cycle •• •• ••Cooling & VentilationAuto Heat-Cool Switchover - - ••Cool Group Master - - ••Cool Group Member •• •• -Cool Min On and Off Times - - ••Auto/Adjustable Cooling Cycle - - ••Cooling Interlock - - ••Ventilation Fan - - ••SetbackOptimum Start •• •• ••Schedule Member •• •• ••Scenes •• •• ••Away Override Temperature •• •• ••

tekmarNet® House Controls 400 401 402Number of Boilers 1 1 1Modulating Boiler (0-10 V (dc)) •• •• ••Number of On-Board Zones 4 4 4Zone Valves (v) or Pumps (p) v p vNumber of Water Temperatures 1 1 2Zone Expansion Capacity 24 24 24 + 24tN4 Boil Expansion •• •• ••tN4 Mix Expansion - - ••Boiler OperationBoiler Outdoor Reset •• •• ••Boiler Auto Differential •• •• ••DHW OperationSelectable DHW Priority •• •• ••DHW through Pump •• •• ••Setpoint OperationAdjustable Setpoint Target •• •• ••Mixing OperationMixing Outdoor Reset - - ••Variable Speed Output - - ••Floating Action Output - - ••Analog 0-10 V (dc)* - - ••Boiler Return Protection - - ••System Maximum Supply •• •• ••Energy Saving Features

Warm Weather Shut Down •• •• ••Energy Use Monitor •• •• ••Energy $aving Indicator •• •• ••DHW Disable During Away •• •• ••Boiler Post Purge •• •• ••

*When using On/Off Boiler

tekmarNet® Wiring Centers 313 3142 Wire / tekmarNet®2 •• ••Zone Pumps - 4Zone Valves 4 -tN4 Expansion •• ••

Feature Comparison

Why Choose tekmar?

tekmar has 25 years of experience controlling hydronic heating

systems. With reliable, cost effective controls that are easy to install

and program, there is no reason to settle for a less effi cient system.

Choose tekmar and benefi t from our world class technical support,

training and a network of experienced local representatives.

7 of 8 © 2009 P 523 - 07/09

Page 8: tekmar House Control Systems · tekmar has 25 years of experience controlling hydronic heating systems. With reliable, cost effective controls that are easy to install and program,

tekmar Control Systems Ltd., Canadatekmar Control Systems, Inc., U.S.A.Head Office: 5100 Silver Star RoadVernon, B.C. Canada V1B 3K4(250) 545-7749 Fax. (250) 545-0650Web Site: www.tekmarcontrols.com

Product design, software and literature are Copyright © 2009 by:tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 8 of 8 All specifications are subject to change without notice.

Printed in Canada. P 523 - 07/09.

Additional applications can be downloaded from the Literature section of the tekmar website.

BoilerSupplySensor

OutdoorSensor

Cooling Air Handler

Condenser

SystemPump

DHWPump

Single Modulating Boiler for Space Heating & DHW. Air Cooling

BoilerSupplySensor

DHWPump

OutdoorSensor

Single Modulating Boiler for Space Heating & DHW.

BoilerSupplySensor

MixSupplySensor

DHWPump

OutdoorSensor

Single On/Off Boiler for Space Heating & DHW. Two Water Temperatures.

400

527 or 528

527 or 528

401

402

527 or 528

BoilerSupplySensor

SystemPump

DHWPump

OutdoorSensor

Single Modulating Boiler for Space Heating & DHW. Remote Manifold.

527 or 528

400

527 or 528

313

314

527 or 528

402

530