TC1 Automation Processor Automation Processor suitable for interface and control of universal brands of following equipment types. ( Examples only...) Technical Specifications Processor: Operating system: Ethernet: 32 bit ARM core with dedicated ethernet core RAY-OS Real time pre emptive, multi threaded, multi tasking kernel IR ports: 6 IR ports Minimum drive of 2 IR emitters per port 1 built in IR blaster for line of site IR emission 10khz-1Mhz carrier capacity I/O ports: 4 TTL I/O ports 0-12 VDC active low Falling edge / Rising edge / active low event programmable Debounced for noise surpression Real time Clock: Temperature compensated ( TCXO ) battery backed clock Clock events configurable for daily / specific and seasonal time scheduling Status indicators: Front panel indicators for ethernet,serial,I/O,relays,IR ports Operating conditions: 0-40 degrees centigrade ambient 0-95% relative humidity. Non condensing Construction: Pearl white ABS enclosure Dimensions: Height: 52 mm Width: 250 mm Depth: 175 mm Professional lighting dimming and control systems having infra-red remote controls or RS-232/RS-485 network based control Non dimming and switching systems via suitable networkable relays on RS-485 serial ports Motorised curtains,drapes,roller blinds,shears ,screens,lifts etc. via infra red or relay control Weight: Gross weight TBD Audio sources, selectors, pre amplifiers, mixers, receivers, media players etc. having an infra red remote control or serial port Video equipment such as all types of televisions,projectors,DVD and blue ray players,media players via infra read and serial ports. Composite video,S-video,HDMI,VGA switchers,scalers and routers via ir remote control and Rs232 serial ports. Third party systems such as fire alarms,burglar alarms,acess control systems,IP camera,PTZ cameras,gas detectors etc. 10/100BaseT,auto negotiating,full/half duples,static IP or DHCP, auto MDI-MDIX,TCP/IP,UDP Specifications subject to change TC-1 Electrical Diagram Mounting Dimensions DC supply RS-232 / 422 / 485 Ports Relay Ports: 4 Low voltage relay ports 24 vdc 1A MOV protected relays Serial ports: 2 serial ports each configurable for following protocols:- RS-232 RS-422 RS-485 System Bus: Raynet 2.0 IR capture: Built in Infra Red capture for learning new remote control commands in conjunction with Design Express software Waveform display with editing for high accuracy capture Boot time: Complete reboot in 5 seconds Power supply: External 15-24 VDC 0.75A (max) Serial ports RS-232 / 422 / 485 Relay 1 Relay 2 Relay 3 Relay 4 I/O 1 I/O 2 I/O 3 I/O 4 I/O 0 I/R 1 I/R 2 I/R 3 I/R 4 I/R 5 I/R 6 I/R 7 Ethernet USB IR Capture System Bus 250mm 175mm 52mm
7

TC-1_2015

Jan 09, 2017

Download

Documents

Ravi Prakash
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: TC-1_2015

TC1Automation Processor

Automation Processor suitable for interface and control of universal brands of following equipment types. ( Examples only...)

Technical Specifications

Processor:

Operating system:

Ethernet:

32 bit ARM core with dedicated ethernet core

RAY-OSReal time pre emptive, multi threaded, multi tasking kernel

IR ports:6 IR portsMinimum drive of 2 IR emitters per port1 built in IR blaster for line of site IR emission10khz-1Mhz carrier capacity

I/O ports:

4 TTL I/O ports0-12 VDC active lowFalling edge / Rising edge / active low event programmableDebounced for noise surpression

Real time Clock:Temperature compensated ( TCXO ) battery backed clockClock events configurable for daily / specific and seasonal time scheduling

Status indicators: Front panel indicators for ethernet,serial,I/O,relays,IR ports

Operating conditions:0-40 degrees centigrade ambient0-95% relative humidity. Non condensing

Construction: Pearl white ABS enclosure

Dimensions:Height: 52 mmWidth: 250 mmDepth: 175 mm

Professional lighting dimming and control systems having infra-red remote controls or RS-232/RS-485 network based control

Non dimming and switching systems via suitable networkable relays on RS-485 serial ports

Motorised curtains,drapes,roller blinds,shears ,screens,lifts etc. via infra red or relay control

Weight: Gross weight TBD

Audio sources, selectors, pre amplifiers, mixers, receivers, media players etc. having an infra red remote control or serial port

Video equipment such as all types of televisions,projectors,DVD and blue ray players,media players via infra read and serial ports.

Composite video,S-video,HDMI,VGA switchers,scalers and routers via ir remote control and Rs232 serial ports.

Third party systems such as fire alarms,burglar alarms,acess control systems,IP camera,PTZ cameras,gas detectors etc.

10/100BaseT,auto negotiating,full/half duples,static IP or DHCP,auto MDI-MDIX,TCP/IP,UDP

Specifications subject to change

TC-1Electrical Diagram Mounting Dimensions

DC supplyRS-232 / 422 / 485

Ports

Relay Ports:4 Low voltage relay ports24 vdc 1AMOV protected relays

Serial ports:

2 serial ports each configurable for following protocols:-RS-232RS-422RS-485

System Bus: Raynet 2.0

IR capture:Built in Infra Red capture for learning new remote control commands in conjunction with Design Express softwareWaveform display with editing for high accuracy capture

Boot time: Complete reboot in 5 seconds

Power supply: External 15-24 VDC 0.75A (max)

Serial ports

RS-232 / 422 / 485

Relay 1

Relay 2

Relay 3

Relay 4

I/O 1

I/O 2

I/O 3

I/O 4

I/O 0

I/R 1

I/R 2

I/R 3

I/R 4

I/R 5

I/R 6

I/R 7

Ethernet

USB

IR Capture

System Bus

250mm

175m

m52m

m

Page 2: TC-1_2015

Network diagram

TC1Device Layout

TC1S

yste

m b

us

IR (

In

fra r

ed

) p

ort

s

I/O

(I

np

ut

/ O

utp

ut

po

rts)

Rela

y p

ort

sL

ow

vo

ltag

e

Seri

al p

ort

1R

S232/4

22/4

85

Seri

al p

ort

2R

S232/4

22/4

85

Eth

ern

et

LA

N p

ort

US

B p

ort

Reset

sw

itch

DC

su

pp

lyso

cket

IR b

laste

r 1

+5v

+3.3

v

SY

S R

X

SY

S T

X

US

B R

X

US

B T

X

IR c

ap

ture

Seri

al

1 R

X

Seri

al

1 T

X

Seri

al

2 R

X

Seri

al

2 T

X

IO 1

IO 2

IO 3

IO 4

Rela

y 1

Rela

y 2

Rela

y 3

Rela

y 4

IR 1

IR 2

IR 3

IR 4

IR 5

IR 6

IR 7

( B

laste

r )

IR b

laste

r 2

IR b

laste

r 3

TC-1 front panel LED indicators / IR capture / IR blaster

TC-1 back panel connectors and terminations

iPAD DHCP192.168.1.201Connected via wifi

LaptopRunning Design express softwareDHCP192.168.1.202Connected via wifi

PCRunning Design express softwareDHCP192.168.1.203Connected via wired LAN

Wireless RouterIP Address 192.168.1.1DHCP starts at 192.168.1.200

Internet

TC-1Manual IP192.168.1.61Connected via wired LAN

iPAD should be able to ping Laptop ,PC ,TC-1Laptop should be able to ping iPAD ,PC ,TC-1PC should be able to ping iPAD,Laptop, TC-1

Page 3: TC-1_2015

IR Ports

TC1System Bus

TC1

Data

+

Data

-

0 +15-2

4 V

DC

0.2

5A

Data

+

Data

-

0

+15-2

4 V

DC

Syste

m b

us

TC-1 System bus wiring CAT 5 / 6

Raylogic wired TouchPanel

Data

+

Data

-

0

+15-2

4 V

DC

Raylogic GSM interface

IR ports 1 - 6

IR emitter withindicator LED

Ste

reo

3.5

mm

plu

g

Mo

no

3.5

mm

plu

g

IR emitter fitted on device IR sensorwith 3M double sided tape

Tip

Sle

eve

Sleeve -

Tip +

Tip

Rin

g

Sle

eve

Sleeve & Ring -

Tip +

+

+

+

+

Ports can be extended to run up to 150-200 feet using a single CAT-5 pair.An IR amplifier and / or thicker wiring may be required for greater lengths or in case of improper triggering.

Shorted in wiring

Each IR port can drive 2 emitters each connected to a different type of equipment

Mono 6.3mm plug wiring and extension.

Stereo 6.3mm plug wiring and extension.

Page 4: TC-1_2015

IO Ports

TC1IR Capture

TC1

IR b

laste

r P

ort

7

IR c

ap

ture

IR 1

IR 2

IR 3

IR 4

IR 5

IR 6

IR 7

( B

laste

r )

IR b

laste

r P

ort

7

IR b

laste

r P

ort

7

< 1 inch (25mm)

2 inches (50mm)

approx. distance 2 inches (50mm)

LED indicators for IR ports

Contact open

Contact closed

Falling edgeevent single shot

Rising edgeevent single shot

Active lowevent repetitive

Switch pressed Switch released

Switch held pressed

Each IO port when used as an input can have 3 different events defined with different actions programmable for each event.

Relay actuator of third party system.Example: Motion sensors,security, fire alarm, access control etc.

Push button switches / contact closures/ potential free keypad switches

0 = Ground = Common1 / 2 / 3 / 4 = IO used as INPUTs

Pole & N/Ocontacts

IO ports used as INPUTS

IO Outputs driving external relays

0 = Ground = Common1 / 2 / 3 / 4 = IO used as OUTPUTsOutputs are active low PULL down

High Voltage switching relays

IO ports used as OUTPUTS

DCPowerSupply

N LNUP DN

+

-

230 VACCurtain motor

IO Outputs drivingactive low contactsIO 1 / 2 / 3 / 4

0

250mA sink, 5-24VDC

IO ports may be used as single outputs or dual grouped outputs. Grouped outputs have built in interlock and mutually exclusive operation. IO outputs can be programmed as permanent on / off and on for preset durations. ( On is an active low state )

Remote control position for IR capture

Place a book under the remote control to align the remote control emitter in height with the center of the TC-1

Front panel IR capture sensor location

Page 5: TC-1_2015

Serial Ports

TC1Relay ports

TC1

Relay ports driving external relays

Low voltage relay ports.Max. 24 VDC 2A

High Voltage switching relays

DCPowerSupply

N LNUP DN

+

-

230 VACCurtain / Screen motors

Relay ports may be used as single relays or dual grouped relays. Grouped relays have built in interlock and mutually exclusive operation. Relays can be programmed as permanent on / off and on for preset durations.

Motorised curtains low voltagecontact closure points

Potential free Input trigger contacts of security systems,fire alarms, access control systems etc.

Low voltage relay ports.driving solid state relays.

DCPowerSupply

N L

+

-

230 VAC

AC

230 V

AC

DC

3-1

2v

Solid state relay

+

-

Load

Serial Ports with RS-232 / RS-422 / RS-485 options

TC-1 RS-232 Port

1 2 3 4 5

6 7 8 9

RXTXGND

235

Slave RS-232 device

TC-1 RS-422 Port

1 2 3 4 5

6 7 8 9

RS 422 Receive Data -

GND

165

RS-422 device 1

RS 422 Receive Data +

49

RS 422 Transmit Data +RS-422 Transmit Data -

RS-422 device 2 RS-422 device 3

up to 10 slave devices

Twisted pair

Twisted pair

RX

+R

X-

TX

-T

X+

0T

X+

RX

+R

X-

TX

-T

X+

0T

X+

RX

+R

X-

TX

-T

X+

0T

X+

DB-9 male Pin Function Direction

2 RXD Input

3 TXD Output

5 Ground

7 RTS Output

8 CTS Input

RS

-232

Feature Description

Max. devices 2

Wire type 3/4 core shielded

Wire length max. 12m - 15m

Communication Full duplex

RS

-232

Speed 1200-115200 bps

DB-9 male Pin Function Direction

1 RXD - Input

6 RXD +

Output

5 Ground

4 TXD+

Output9

RS

-422

Feature Description

Max. devices 10

Wire type Twisted pair CAT 5 / 6

Wire length max. 1000m

Communication Full duplex

RS

-422

Speed 1200-115200 bps

Input

TXD-

The serial ports are configured for type / baud rate / stop bits in the serial library of the DESIGN EXPRESS software for windows.

Page 6: TC-1_2015

TC1LAN / USB / RESET / DC

TC1

230 VAC 50 hz.

15-18 VDC 750mA

DC

adapto

r

Laptop / PC running Design express windows software for TC-1 programming.

US

B c

able

LA

N c

able

Reset SwitchPush to reboot automation processor.Typically 5 seconds for a complete reboot.

Wireless Router

TC-1 RS-485 Port

1 2 3 4 5

6 7 8 9

GND5

RS-485 device 1

4+61+9

RS-485 Data +RS-485 Data-

RS-485 device 2 RS-485 device 3

up to 31 slave devices

Twisted pair

DB-9 male Pin Function Direction

1 + 9 Data - Input / Output

4 + 6 Data +

5 GroundRS

-485

Feature Description

Max. devices 32

Wire type Twisted pair CAT 5 / 6

Wire length max. 1000m

Communication Half duplex

RS

-485

Speed 1200-115200 bps

Input / Output

Serial Ports

Page 7: TC-1_2015

TC1TC1FAQ