    1/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    Contents

    Panelboards 1

    P

    anelboard

    s

    Description Page

    EZ Box and EZ Trim

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-2

    Product Selection

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-4

    Product Description

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-5

    Application Description

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-6

    Standards and Certifications

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-8

    Technical Data and Specifications

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-9

    Type PRL1a Lighting Panelboard, 240 Vac Maximum

    . . . . . . . . . . . . . . . . . . 14-21

    Type PRL2a Lighting Panelboard, 480Y/277 Vac Maximum

    . . . . . . . . . . . . . 14-23

    Type PRL3a Lighting or Small Power Panelboard, 600 Vac Maximum

    . . . . 14-25

    Type PRL4 Power Distribution Panelboard, 600 Vac Maximum

    . . . . . . . . . . 14-28

    Type PRL1a-LX Column Type Panelboard, 240 Vac Maximum

    . . . . . . . . . . . 14-39

    Type PRL2a-LX Column Type Panelboard, 480Y/277 Vac Maximum

    . . . . . . 14-42

    Box Trim and Pricing

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-45

    Modifications (1a, 2a, 3a, 4, Column Type)

    . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-46

    Type PRL5P Power Distribution Panelboard, 600 Vac Maximum, Plug-on

    . . . . 14-53Pow-R-Command

    Lighting Control

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-60

    Renovation Panelboard PRL1R

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-75

    Metering Service Sections

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-84

    Pow-R-Stock Plus Program

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-86

    Regional Manufacturing Facilities

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-87

    Type PRL1a Panelboard

  • 7/13/2019 Tb 01400001 e

    2/89

    February 2007

    14-2

    For more information visit: www.eaton.com

    CA08101001E

    Panelboards

    4

    EZ Box and EZ Trim

    EZ

    Box and EZ Trim

    Flange Detail

    Eatons new EZ box and EZ trimrepresents the first significant change

    in panelboard box and trim designs inmore than a half-century. The EZ boxand EZ trim have been designed forfaster, more secure and safer installa-tions. The new EZ box and EZ trim areprovided standard for Cutler-HammerPow-R-Line 1a and Pow-R-Line 2alighting panelboards, as well as ourPow-R-Line 3a mid-range panelboard.

    Features

    Virtually eliminates sharp edges.

    Trim installs in seconds ratherthan minutes.

    Door-in-door is standard.

    Ability to adjust flush box to wallirregularities.

    Trim installs without the needfor tools.

    No exposed hardware (becausethere is none).

    Multipoint door latch over breakers.

    The EZ box flanges are bent andpainted, which virtually eliminatesthe sharp edges associated withtraditional boxes. Additionally, all steelpanelboard chassis parts are painted.This significantly reduces potentialinjury for material handlers and install-ers. Each flange is adjustable outward

    up to 3/4 inch. This feature allowsthe installer to adjust flush boxapplications to be level and flat with

    the finished wall after the wallmaterial is installed to help correctwall irregularities. The new box flangealso provides the means for attachingthe EZ trim.

    Corner Flange Detail

    Stand-alone Trim and Bottom Flange Hanger with Notch

  • 7/13/2019 Tb 01400001 e

    3/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    1Panelboards

    EZ Box and EZ Trim

    Fast Installation

    The EZ trim incorporates a patent pending, ground breakingdesign that installs in seconds, rather than minutes. Thestandard trim features include door-in-door construction;no exposed hardware and no tools are required forinstallation.

    Each EZ trim includes hangers attached on the right side.The bottom trim hanger has a notch in its base. To install,the bottom hanger is inserted into the bottom right sidebox flange opening, resting the notch on the flange.

    Trim Hanger Inserted Into Box Flange

    The balance of the hangers are aligned with the other flangeopenings and pushed in. When all hangers are in the boxflange, the trim is lifted up slightly to clear the notch on thebottom hanger, and the trim in self-supported on the EZ box.

    The installation is completed by swinging the trim to theclosed position, then lifting and pushing slightly to the right.The trim will drop into place totally secured. The multi-pointcatches on the left side of the trim will lock into the left side

    box flange openings.

    To prevent the trim from being removed by non-authorizedpersons, a unique sliding means automatically latchesin place when the trim door is closed. For added safety, ascrew is provided to secure the latch for those who requireextra security.

    The new EZ trim utilizes an exclusive catch systemthat fastens the door to multiple points. Along with a newlock, the EZ trim offers a high degree of door security.

    Standards

    When used with Eatons Cutler-Hammer panelboard chassis,EZ boxes and EZ trims meet the following applicableindustry standards:

    UL

    50 listed.

    NEMA

    Standard PB1.

    Federal specifications.

    National Electrical Code

    .

    Trim Hanging on Surface Mounted Box

    Trim Installed with Door Open and Trim Sliding Latch

    New Lock

  • 7/13/2019 Tb 01400001 e

    4/89

    February 2007

    14-4

    For more information visit: www.eaton.com

    CA08101001E

    Panelboards

    4

    Pow-R-Line C Panelboards

    Product Selection

    Product Types

    Type PRL1a

    Bolt-on or Plug-on Circuit Breakers240 Vac Maximum

    Main Lugs Only400 amperes maximum.

    Main Circuit Breaker400 amperes maximum.

    Branch Circuit Breakers100 amperes maximum,1-, 2- and 3-pole.

    Type PRL1a

    Type PRL2a

    Bolt-on Circuit Breakers240 V or 480Y/277 Vac; 125/250 Vdc Maximum

    Main Lugs Only400 amperes maximum.

    Main Circuit Breaker400 amperes maximum.

    Branch Circuit Breakers100 amperes maximum,1-, 2- and 3-pole.

    Type PRL2a

    Type PRL3a

    Bolt-on Circuit Breakers240 V, 480 V or 600 Vac; 250 Vdc Maximum

    Main Lugs Only800 amperes maximum.

    Main Circuit Breaker600 amperes maximum.

    Branch Circuit Breakers225 amperes maximum,1-, 2- and 3-pole.

    Type PRL3a

    Type PRL4

    Circuit Breakers or Fusible Switches240 V, 480 V or 600 Vac; 250 Vdc Maximum

    Main Lugs Only1200 amperes maximum.

    Main Circuit Breaker1200 amperes maximum.

    Main Fusible Switch1200 amperes maximum.

    Branch Circuit Breakers1200 amperes maximum,1-, 2- and 3-pole.

    Branch Fusible Switches1200 amperes maximum,2- and 3-pole.

    Type PRL4

    Type PRL5P

    Plug-on Circuit Breakers240 V, 480 V or 600 Vac; 250 Vdc Maximum

    Main Lugs Only1200 amperes maximum.

    Main Circuit Breaker1200 amperes maximum.

    Branch Circuit Breakers1200 amperes maximum,1-, 2- and 3-pole.

    Type PRL5P

    Pow-R-Command

    Bolt-on Circuit Breakers240 V or 480Y/277 Vac

    Main Lugs Only400 amperes maximum.

    Main Circuit Breaker400 amperes maximum.

    Branch Circuit Breakers225 amperes maximum,1-, 2- and 3-pole.

    Integral Power Switching Controls.

    Pow-R-Command

  • 7/13/2019 Tb 01400001 e

    5/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    1Panelboards

    Pow-R-Line C Panelboards

    Product Description

    Product Types (Continued)

    Type PRL1a-LX Column Type

    Bolt-on Circuit Breakers 240 Vac Maximum

    Main Lugs Only

    225 amperes maximum.

    Main Circuit Breaker225 amperes maximum.

    Branch Circuit Breakers100 amperes maximum,1-, 2- and 3-pole.

    Type PRL1a-LX Column Type

    Type PRL2a-LX Column Type

    Bolt-on Circuit Breakers240 V or 480Y/277 Vac; 125/250 Vdc Maximum

    Main Lugs Only225 amperes maximum.

    Main Circuit Breaker225 amperes maximum.

    Branch Circuit Breakers100 amperes maximum,1-, 2- and 3-pole.

    Type PRL2a-LX, Column Type

    Renovation Panelboard PRL-IR

    Bolt-on Circuit Breakers 240 Vac Maximum

    Main Lugs Only225 amperes maximum.

    Main Circuit Breaker

    225 amperes maximum.

    Branch Circuit Breakers100 amperes maximum,1-, 2 and 3-pole.

    Renovation Panel

    Metering Service Section

    Bolt-on Circuit Breaker or Fusible Switch240 V, 480 V or 600 Vac

    Service entrance panels combininga main disconnect with a powercompany metering compartment.400 1200 amperes.

    Metering Service Section

    Product Description

    Lighting and DistributionPanelboards

    Eatons Cutler-Hammer

    assembled

    panelboards are designed forsequence phase connection of branchcircuit devices. This allows completeflexibility of circuit arrangement(1-, 2- or 3-poles) to allow balance ofthe electrical load on each phase.

    Sturdy, rigid chassis assembly ensuresaccurate alignment of interior withpanel front; prevents flexing andminimizes possibility of looseningor damage to current carrying partsduring and after installation.

    Four-point in-and-out adjustment ofpanel interior is provided to meet criti-cal depth dimensions on flush installa-

    tions. This compensates for possiblemisalignment of box at installation.

    Main lugs are mechanical solderlesstype and approved for copper oraluminum conductors.

    Enclosures

    Boxes are code-gauge galvanized steelexcept for column type panelboardswhich include a painted box finished inANSI-61 light gray to match the trim.

    Standard panelboard cabinets aredesigned for indoor use. Alternatetypes are available for indoor andspecial purpose applications.

    All enclosures are furnished in accor-dance with Underwriters Laboratoriesstandards and include wiring gutterswith proper wire bending space.Special cabinets can be providedat an additional charge.

    The box dimensions shown are insidedimensions. For outside dimensions,add 1/4-inch (6.4 mm).

    Standard panelboard boxes are supplied

    without knockouts (blank endwalls).

    Fronts

    Fronts (trims) for all panelboards are

    made of code-gauge steel and havea high durability ANSI-61 light grayfinish applied by a baked-on polyesterpowder coating paint system.

  • 7/13/2019 Tb 01400001 e

    6/89

    February 2007

    14-6

    For more information visit: www.eaton.com

    CA08101001E

    Panelboards

    4

    Pow-R-Line C Panelboards

    Application Description

    The fronts for lighting and appliancebranch circuit panelboards and smallpower distribution panelboards includea door with rounded corners and con-cealed hinges. A flush-type latch andlock assembly is included. All locks arekeyed alike. These trims are available inboth surface and flush mounted designs.

    EZ Trim Features Standard Door-in-Doorwith No Exposed Hardware or Sharp Edges(no Tools are Required for Installation)

    The Three-Piece Trim for Larger PowerDistribution Panelboards Provides for EasyHandling and Installation

    Fronts for power distribution panel-boards utilize a unique breaker frontcover design in which each device hasa dedicated bolt-on steel cover. Theindividual covers form a single dead-front for the panelboard that is usedin conjunction with two wiring guttercovers to complete the trim. A dooris not finished as part of the standardoffering on these panelboards but canbe provided, for an additional charge,using a deeper than standard box.

    Application Description

    Panelboard Selection FactorsIn selecting a panelboard, the follow-ing factors must be considered:

    Service (voltage and frequency). Interrupting capacity (fully or

    series rated).

    Ampere rating of main.

    Ampere ratings of branches.

    Environment.

    Panelboard Short Circuit RatingThe short circuit rating of EatonsCutler-Hammer assembled panel-boards are test verified by, and listedwith, Underwriters Laboratories(UL).Generally, these ratings are that ofthe lowest interrupting rated devicein the panel.

    Certain exceptions to this rule existwhere branch devices have been ULtested in combination with specificmain devices having a higher inter-rupting rating. Where these definedmain devices and branch breaker com-binations are utilized, the Series ShortCircuit Ratingof the assembled panel-board will be the same as the testedrating of the approved rated maindevice in series with the branches.Available main and branch breakercombinations are tabulated startingon Page 14-12. All combinationsshown are UL tested and listed.

    These series ratings apply to panelshaving main devices, or main lugonly panelboards fed remotely bythe device listed in the series ratingschart as the main, for which UL listedtests were conducted.

    Service Entrance EquipmentThe National Electrical Code (NEC)requires that:

    A panel used as service entranceequipment must be located near thepoint where the supply conductorsenter the building.

    A panelboard having main lugs onlyshall have a maximum of six servicedisconnects to de-energize theentire panelboard from the supplyconductors. Where more thansix disconnects are required, amain service disconnect mustbe provided.

    A disconnectable electrical bondmust be provided between theneutral and ground.

    A service entrance type UL labelmust be factory installed.

    Ground fault protection of equip-ment shall be provided for each ser-vice disconnect rated 1000 amperesor more if the electrical service is

    a solidly grounded wye systemof more than 150 volts to groundbut not exceeding 600 volts phase-to-phase.

    Note: Service entrance panels must beidentified as such on the order.

    Panelboard ClassificationsPanelboards are classified by NEC andUL in two general categories: Lightingand Appliance Panels and PowerDistribution Panels.

    Lighting and Appliance PanelboardsLighting and appliance branch circuit

    panelboards are defined in NEC(Article 408) as one having more than10 percent of its overcurrent devicesrated 30 amperes or less for whichneutral connections are provided.Article 408 also limits the number ofovercurrent devices (branch circuit-poles) to a maximum of 42 in any onecabinet. This rule applies to all paneltypes including PRL4 when the panelcircuitry comes within the scope of thisdefinition. When the 42 devices (poles)are exceeded, two or more separatepanels are required.

    Power Distribution PanelboardsDistribution panelboards (all othersnot defined as lighting and appliancebranch circuit panelboards) arerestricted only to practical physicallimitations such as standard boxheights and widths. It is importantto note that the NEC requires thatthe operating handle of the topmostmounted device be no more than6 feet 7 inches (2006.6 mm) abovethe finished floor.

    Additional boxes and fronts arerequired when the componentsrequired for one panelboard exceedthe standard box dimensions.

    Multi-Section PanelboardsWhen more than 42 overcurrentprotective devices are required (See,Lighting and Appliance Panelboards),two or more separate enclosures arerequired. Separate fronts for each boxare standard. A common front canbe furnished at additional charge.

  • 7/13/2019 Tb 01400001 e

    7/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    1PanelboardsPow-R-Line C Panelboards

    Interconnecting Multi-SectionPanelboardsWhen a panelboard, for connection toone feeder, must be furnished in morethan one section (Box), each sectionmust be furnished with main bus andterminals of the same rating, unlessa main overcurrent device is providedin each section.

    Sub-feed or through-feed provisionsmust also be included (and priced) toprovide connection capability to thesecond section.

    Note: Sub-feed or through-feed lugs can-not be used on any panelboard that is notprotected by a single main overcurrentdevice either in the panelboard or immedi-ately upstream, i.e., service entrance panel-boards with main lugs only using the sixdisconnect rule.

    Sub-Feed LugsSub-feed lugs (see Figure 14-1) areone means of interconnecting multi-section panels. The sub-feed (secondset of) lugs are mounted directlybeside the main lugs. These arerequired in each section except the lastpanel in the lineup. The feeder cablesare brought into the wiring gutter ofthe first section and connected to themain lugs. Another set of the samesize cables are connected to the sub-feed lugs (Section 1) and are carriedover to the main lugs of the adjacentpanel. Cross connection cables are notfurnished by Eaton. Sub-feed lugs areonly available on main lug only panels.

    Note: Sub-feed lugs may not be used onmain lug only (six disconnect rule) serviceentrance panels.

    Figure 14-1. Sub-Feed Lugs

    Through-Feed LugsThrough-feed lugs (see Figure 14-2)are another method to interconnectmulti-section panelboards. The incom-ing feeder cables are connected to themain lugs or main breaker at the bot-

    tom of panel (Section 1). Another setof lugs (through-feed) are located atthe opposite end of the main bus. Theinterconnecting cables are connectedto the through-feed lugs in Section 1and are carried over to the main lugsin Section 2. The connection arrange-ment could be reversed, i.e., main lugsat top; through-feed lugs at bottomend of panel. Cross cables are notfurnished by Eaton.

    Note: Through-feed lugs may not beused on main lug only (six disconnect rule)service entrance panels.

    Figure 14-2. Through-Feed Lugs

    Multiple Section Panelboard Flush MountedShown below is the standard methodfor flush mounting multiple sectionlighting and distribution panelboardsusing standard flush trims.

    Figure 14-3. Multiple Section PanelboardFlush Mounted Dimensions in Inches (mm)

    Overcurrent ProtectionThe following requirements will befound in the NEC:

    Each lighting and appliance branchcircuit panelboard shall be individuallyprotected on the supply side by notmore than two main circuit breakers ortwo sets of fuses having a combinedrating not greater than that on thepanelboard.

    Box Box

    Conduit

    Neutra Neutra

    Panel

    anel

    Section 1 Section 2

    Section 1 Section 2

    Box Box

    Conduit

    Neutral

    Panel

    Panel

    Neutral

    a nLugs

    Thru-FeedLugs

    MainLugs

    Cross Cables

    Incoming Feeder Cables

    Contractor to Mount Boxes1-1/2-inch (38.1 mm) Apart toAllow for 3/4-inch (19.1 mm)Extension on Both Flush Trims

    Two SectionPanelboard(Flush Mounting)

    rim Extends 3/4-inch(19.1 mm) Beyond Outside

    f Box on All Four Sides

    Outside Edge of Boxrim

    W ll WallTrim Trim

    onduit Nipple for Cross Wiring by Contractor

    3/4(19.1)

    3/4(19.1)

    1 1/238.1)

    Top SectionView

    3/4(19.1)

    3/4(19.1)

    3/4(19.1)

    3/4(19.1)

    3/419.1)

    3/419.1)

    3/4(19.1)

    3/419.1)

  • 7/13/2019 Tb 01400001 e

    8/89

    February 2007

    14-8

    For more information visit: www.eaton.com CA08101001E

    Panelboards

    4

    Pow-R-Line C Panelboards

    Standards and Certifications

    Branch Circuit Loading for Lightingand Appliance PanelsThe size of mains and branches shouldbe selected based on the following:

    Lighting and distribution circuits:

    NEC Article 210, 215, 220 and 240. Motor circuits: NEC Article 430.

    Diversity factor.

    Provision for future loading.

    Exception Number 1:Individual pro-tection for a lighting and appliancepanelboard is not required when thepanelboard feeder has overcurrentprotection not greater than that ofthe panelboard.

    Exception Number 2:For existinginstallations, individual protection forlighting and appliance branch circuitpanelboards is not required where

    such panelboards are used as serviceequipment in supplying an individualresidential occupancy and where anybus supplying 15 or 20 ampere circuitsis protected on the supply side by anovercurrent device.

    Ambient TemperaturesThe primary function of an overcurrentdevice is to protect the conductor andits insulation against overheating. Inselecting the size of the devices andconductors, consideration should begiven to the ambient temperature sur-rounding the conductors within andexternal to the panelboard. Cumula-

    tive heating within the panelboardmay cause premature operation ofthe overcurrent protective devices.

    Underwriters Laboratories testprocedures are based, in part, on 80%loading of panelboard branch circuitdevices. The NEC limits the loading ofovercurrent devices in panelboards to80% of rating where in normal opera-tion the load will continue for threehours or more. Further derating maybe required, depending on such factorsas ambient temperature, duty cycle,frequency or altitude.

    Exception:There is one exception tothis rule in both UL and NEC. It appliesto assemblies and overcurrent deviceswhich have been approved for contin-uous duty at 100% of its rating.

    Special ConditionsStandard panelboards, assembledwith standard components, are ade-quate for most applications. However,special consideration should be givento those required for application under

    special conditions such as:

    Excessive vibration or shock.

    Frequencies above 60 cycles.

    Altitudes above 6600 feet (2011.7 m).

    Damp environment (possible fungusgrowth).

    Compliance with federal, stateand municipal electrical codesand standards.

    Seismic ConsiderationsThe Uniform Building Codeand theInternational Building Code 2003, aswell as local and state building codes,

    place an emphasis on seismic buildingdesign requirements. Electricaldistribution systems are treatedas attachments to the building andtherefore, fall into this category.

    All Eatons Cutler-Hammer panel-boards are seismic qualified at thehighest possible level, Seismic Zone 4,and have been tested in accordancewith ANSI C37.81. This standard quan-tifies actual earthquake conditions, aswell as equipment seismic capability.

    Harmonic CurrentsStandard panelboard neutrals are

    rated for 100% of the panelboardcurrent. However, since harmoniccurrents can cause overheatedneutrals, an option is provided forneutrals to be rated at 200% (1200ampere maximum neutral for 600ampere main bus) of the panelboardphase current.

    Panelboards with the 200% ratedneutral are UL listed as suitable foruse with non-linear loads.

    Prior to specifying the 200% ratedneutral, Eaton recommends a harmonicsurvey be conducted of the distributionsystem, be it new or existing.

    Transient Voltage Surge SuppressionThe quality of power feeding sensitiveelectronic loads is critical to the reliableoperation of any facility. In modernoffices, hospitals, and manufacturingfacilities, the most frequent causes ofmicroprocessor-based equipmentdowntime and damage are voltagetransients and electrical noise.

    Electrical loads and microprocessor-based equipment are highly susceptibleto both high and low energy transients.High energy transients include lightninginduced surges and power companyswitching. These high energy transientscan destroy components instantly.

    More frequently the electrical systemexperiences low energy transients andhigh frequency noise.

    The effects of continual low energytransients and high frequency noisecan cause erratic equipment perfor-mance or sudden failure of electroniccircuit board components.

    Eaton can provide protective and diag-nostic systems integral to panelboards.The Clipper Power System Visor Seriesis integrated into the panelboardsusing a zero lead length direct busbar connection.

    Pow-R-Line 4

    The CPS Visor Series providesTransient Voltage Surge Suppression(TVSS) and active hybrid filtering.The CPS protects sensitive electronicequipment from the damaging effectsof high and low energy transients,as well as high frequency noise.

    Standards and Certifications

    Eatons Cutler-Hammer panelboardsare designed to meet the followingapplicable industry standards, exceptwhere noted:

    Underwriters Laboratories:

    Panelboards: UL 67

    Cabinets and Boxes: UL 50

    Note: Only panelboards containingUL listed devices can be UL labeled.

    National Electrical Code.

    NEMAStandards: PB 1.

    Federal Specification W-P-115c:

    Circuit Breakers Type I Class I

    Fusible Switch Type II Class I

  • 7/13/2019 Tb 01400001 e

    9/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    1PanelboardsPow-R-Line C Panelboards

    Technical Data and Specifications

    Technical Data and Specifications

    Selection GuideTable 14-1. Panelboard Selection Guide

    Terminal Wire Ranges, Pressure-TypeAl/Cu Terminals Except as NotedNote: All terminal sizes are based on wireampacities corresponding to those shown inNEC Table 310-16 under the 75C insulationcolumns (75C wire). The use of smaller size,(in circular mills), regardless of insulationtemperature rating, is not permitted.

    Where copper-aluminum terminals aresupplied on designated panelboardtypes, best results are obtained if asuitable joint compound is appliedwhen aluminum conductors are used.

    Check Eatons Cutler-Hammer standardterminal sizes versus customerrequirements. In particular, 400 and

    800 ampere breakers often requirenonstandard lugs.

    Optional 750 kcmil mechanicalscrew-type terminals are availableupon request. Panelboard dimensionsmay be affected, refer to Eaton.

    Table 14-2. Standard Main Lug Terminals

    PanelboardType

    DeviceType

    MaximumVoltage Rating

    Maximum MainRating (Amperes)

    Branch CircuitsAmpere Range

    Sub-Feed BreakerMaximum Amperes

    AC Interrupting Capacityrms Symmetrical Amperes (kA)

    ac dc MLO Main Device Fully Rated Series Rated

    PRL1a Breaker 240 400 400 15 100 400 10 22 22 100

    PRL2a BreakerBreaker

    240480Y/277

    250250

    400 400

    400 400

    15 10015 100

    400400

    65 14

    65 20022 150

    PRL3a BreakerBreakerBreaker

    240480600

    250250250

    800 800 800

    600 600 600

    15 22515 22515 225

    600600600

    10 200 14 100 14 35

    22 20022 150

    PRL4B BreakerBreakerBreaker

    240480600

    250250250

    120012001200

    120012001200

    15 120015 120015 1200

    10 200 14 200 14 200

    22 20022 150

    PRL4F FusibleFusible

    240600

    250250

    12001200

    12001200

    30 120030 1200

    100 200100 200

    PRL1a-LX Breaker 240 225 225 15 100 10 22 22 100

    PRL2a-LX BreakerBreaker

    240480Y/277

    250250

    225 225

    225 225

    15 10015 100

    65 14

    65 20022 150

    PRC100/50PRC25

    BreakerBreaker

    240480Y/277

    400 400

    400 400

    15 22515 225

    10 65 14

    22 10065 100

    PRL5P BreakerBreakerBreaker

    240480600

    250250250

    120012001200

    120012001200

    15 120015 120015 1200

    10 200 14 200 14 200

    22 20022 150

    PanelType

    Wire Size Ranges for Ampere Capacity

    100 Ampere 225 Ampere 250 Ampere 400 Ampere 600 Ampere 800 Ampere 1200 Ampere

    PRL1aPRL2aPRL3aPRL4

    #12 #1/0#12 #1/0#12 #1/0

    #6 300 kcmil#6 300 kcmil

    #6 350 kcmil#4 500 kcmil

    (2) #4 500 kcmil(2) #4 500 kcmil(2) #4 500 kcmil(2) #4 500 kcmil

    (2) #4 500 kcmil(2) #4 500 kcmil

    (3) #4 500 kcmil(3) #4 500 kcmil

    (4) #4 500 kcmil

    PRL1a-LXPRL2a-LX

    #12 #1/0#12 #1/0

    #6 300 kcmil#6 300 kcmil

    PRC100PRC50

    #12 #1/0 #6 350 kcmil (2) #4 500 kcmil

    PRC25 #12 #1/0 #6 300 kcmil (2) #4 500 kcmil

    PRL5P (1) #1/0 500 kcmilor(2) #1/0 250 kcmil

    (2) #4 500 kcmil (2) #2 500 kcmilor(3) #2 400 kcmil

    (4) #4 750 kcmil

  • 7/13/2019 Tb 01400001 e

    10/89

    February 2007

    4-10

    For more information visit: www.eaton.com CA08101001E

    Panelboards

    4

    Pow-R-Line C Panelboards

    Technical Data and Specifications

    Selection Guide (Continued)

    Table 14-3. Standard Circuit Breaker Terminals

    BreakerType

    AmpereRating

    WireRange

    BAB, QBHWHQP, QPHW

    15 70 90 100

    #14 #4 #8 #1/0

    EDB, EDS, ED,EDH, EDC

    100 225 #4 4/0 or #6 300 kcmil

    EHD, FDB, FD,HFD, FDC

    15 100 125 225

    #14 1/0 #4 4/0

    FCL 15 100 #14 1/0

    GHB, HGHB, GHQ 15 20 25 100

    #14 #10#10 1/0

    JD,HJD, JDC

    70 250 #4 350 kcmil

    DK 250 350 400

    250 500 kcmil(2) 3/0 250 kcmil or (1) 3/0 500 kcmil

    KD,HKD, KDC,CKD, CHKD

    225 350 400

    (1) #3 350 kcmil(1) 250 500 kcmil(2) 3/0 250 kcmil or(1) 3/0 500 kcmil

    LGE, LGH 250 400 500 600

    (1) #2 500 kcmil(2) #2 500 kcmil

    LD,HLD, LDC,CLD, CHLD

    300 500

    600

    (2) 250 350 kcmil

    (2) 400 500 kcmil

    MDL, HMDL,CMDL,CHMDL

    400 600 700 800

    (2) #1 500 kcmil(3) 3/0 400 kcmil

    ND, HND,CND, CHNDNDC, CNDC

    800 10001200

    (3) 3/0 400 kcmil(4) 4/0 500 kcmil

    LCL 125 225 250 400

    (1) #6 350 kcmil(1) #4 250 kcmil and (1) 3/0 600 kcmil

    FB-P 15 100 #14 1/0

    LA-P 70 225 250 400

    #6 350 kcmil(1) #4 250 kcmil and (1) 3/0 600 kcmil

    NB-P 300 700 800

    (2) #1 500 kcmil(3) 3/0 400 kcmil

    Table 14-4. FDPW Switch Terminals

    AmpereRating

    WireRange

    30 60 100

    #14 1/0#14 1/0#14 1/0

    200 #4 300 kcmil

    400 250 750 kcmil or(2) 3/0 250 kcmil

    600 (2) #4 600 kcmil or(4) 3/0 250 kcmil

    800 (3)250 750 kcmil or(6) 3/0 250 kcmil

    1200 (4) 250 750 kcmil or(8) 3/0 250 kcmil

  • 7/13/2019 Tb 01400001 e

    11/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    14PanelboardsPow-R-Line C Panelboards

    Technical Data and Specifications

    Selection Guide (Continued)Table 14-5. Molded Case Circuit Breaker RatingsNote: Circuit breakers equal or exceed Federal Specification W-C-375b requirements for the particular class associated with each circuit breaker type.

    dc ratings apply to substantially non-inductive circuits. 15 and 20 amperes 1-pole switching duty rated for fluorescent applications. 1-, 2- and 3-pole HACR rated. dc rated 1-pole, 15 70 amperes only. 2- and 3-pole HACR rated. 100% rated circuit breaker. dc rating not available with electronic trip. Available with integral ground fault protection. 100k based on NEMA test procedure.

    BreakerType

    ContinuousAmpereRating

    Numberof Poles

    Voltsac

    UL Listed Interrupting Ratings kA Symmetrical Amperes

    ac Rating Volts dc Rating Volts

    120/240 240 277 480 600 125 250

    BAB, HQP 15 70 15 100 15 100

    122, 3

    120120/240240

    1010

    10

    BABRP, BABRSP 15 30 15 30

    12

    120120/240

    1010

    QBGF, QBGFEP,QPGF, QPGFEPQBAF, QBAG

    15 40 15 50 15 20 15 20

    1212

    120120/240120120/240

    10101010

    QBHW, QPHW 15 70 15 100 15 100

    122, 3

    120120/240240

    2222

    22

    QBHGF, QBHGFEP,QPHGF, QPHGFEP

    15 30 15 30

    12

    120120/240

    2222

    GQ, GHQ

    GHB 15 20 15 100

    15 100

    112, 3

    277277480Y/277

    6565

    65

    1414

    14

    14

    14

    HGHB

    GHBGFEP 15 30 15 60

    11

    277277

    65

    2514

    GHBS 15 30 15 30

    12

    277480Y/277

    65

    65

    14

    14

    EHD 15 100 15 100

    12, 3

    277480

    18

    14

    14

    10

    10

    FDB

    FD 15 150 15 150 15 225

    2, 312, 3

    600277600

    18 65

    35

    14 35

    14 18

    10

    1010

    HFD 15 150 15 225

    12, 3

    277600

    100

    65

    65

    25

    10

    22

    FDC

    FCL 15 225 15 100

    2, 32, 3

    600480

    200200

    100150

    35

    22

    EDB

    EDS

    ED

    EDH

    EDC

    100 225100 225100 225100 225100 225

    2, 32, 32, 32, 32, 3

    240240240240240

    224265100200

    1010101010

    JD

    HJD

    JDC

    70 250 70 250 70 250

    2, 32, 32, 3

    600600600

    65100200

    35 65100

    18 25 35

    102222

    DKKD, CKD

    HKD, CHKD

    250 400100 400100 400

    2, 32, 32, 3

    240600600

    65 65100

    35 65

    25 35

    1010

    22

    KDCLCL

    LGELD, CLD

    100 400125 400250 600300 600

    2, 32, 332, 3

    600600600600

    200200 65 65

    100200 35 35

    65100 18 25

    22

    2222

    LGHHLD, CHLD

    LDC, CLDC

    MDL, CMDL

    250 600300 600300 600400 800

    32, 32, 32, 3

    600600600600

    100100200 65

    65 65100 50

    35 35 50 25

    2225

    25

    22

    HMDL, CHMDL

    ND, CND

    HND, CHND

    NDC, CNDC

    400 800600 1200600 1200600 1200

    2, 32, 32, 32, 3

    600600600600

    100 65100200

    65 50 65100

    35 25 35 65

    25

    Integrally Fused, Current Limiting Circuit BreakersFB-PLA-PNB-P

    15 100 70 400300 800

    2, 32, 32, 3

    600600600

    200200200

    200200200

    200200200

  • 7/13/2019 Tb 01400001 e

    12/89

    February 2007

    4-12

    For more information visit: www.eaton.com CA08101001E

    Panelboards

    4

    Pow-R-Line C Panelboards

    Technical Data and Specifications

    Series Rated CombinationsUnderwriters Laboratories permitspanelboards to be labeled with a shortcircuit rating of up to 200,000 amperes(symmetrical) where UL listed combi-nations of main and branch circuit

    breakers are used.

    These combinations consist of mainbreakers or fusible devices connectedahead of, and in series with approvedconventional breakers used as branchdevices.

    Two arrangements are acceptable andcomply with UL standards for panel-boards. The main circuit breaker orfusible switch may be installed in thepanel as a main device, or it may bemounted remote, (directly upstream)from the panel.In either case, theapproved main and branch combina-tions must be followed. These

    arrangements are acceptable andare UL listed having been tested inaccordance with UL 67 standards.

    From the tables that follow, specificcombinations of main devices(upstream) and branch devices(downstream), series connected andelectrically adjacent in the system,may be selected to qualify theassembled panelboard for the shortcircuit ratings shown.

    Applying Series Ratings

    The following is provided to use theseries rating tables on the followingpages.

    1. Determine the available systemvoltage and fault current.

    2. Select the appropriate table usingthe system voltage.

    3. Use the appropriate SeriesEquipment Rating column equalto, or greater than, the availablefault current, to determine theallowable UL recognized combina-tions of main (upstream) andbranch (downstream) overcurrentdevices. Main devices are shownin bold/shaded areas. Respectivebranch breakers are showndirectly below their associatedmain device. If a rating is not

    initially found in a column, firstlook to the columns to the rightfor higher Series EquipmentRatings within the same table.If still not found, use ratings fromtable of a higher system voltage(higher numbered table(s).

    Table 14-6 on Page 14-13

    120/240 Volts ac Breaker/Breaker

    Table 14-7 on Page 14-14

    240 Volts ac Breaker/Breaker

    Table 14-8 on Page 14-16

    277 Volts ac Breaker/Breaker

    Table 14-9 on Page 14-16

    480Y/277 Volts ac Breaker/Breaker

    Table 14-10 on Page 14-17

    480 Volts ac Breaker/Breaker

    Table 14-11 on Page 14-18

    600 Volts ac Breaker/Breaker

    Table 14-12 on Page 14-18

    120/240 Volts ac Fuse/Breaker

    Table 14-13 on Page 14-19

    240 Volts ac Fuse/Breaker

    Table 14-14 on Page 14-19

    277 Volts ac Fuse/Breaker

    Table 14-15 on Page 14-20

    480Y/277 Volts ac Fuse/Breaker

    Table 14-16 on Page 14-20

    480 Volts ac Fuse/Breaker

    Table 14-17 on Page 14-20

    600 Volts ac Fuse/Breaker

    Table 14-18 on Page 14-20

    Triple Series Ratings

  • 7/13/2019 Tb 01400001 e

    13/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    14PanelboardsPow-R-Line C Panelboards

    Technical Data and Specifications

    Series Rating Tables

    Table 14-6. 120/240 Volts ac Breaker/Breaker Series RatingsMain devices are shown centered at top, in shaded area. Respective branch devices shown directly below.

    MainBreakerMaximumAmperes

    Series Equipment Rating kA Symmetrical

    18 22 42 65 100 200

    100 EHD QBHW GB, GHB FB-P FCL

    BA, BABBABRPBABRSPHQPQBGFQBAFQBAG

    QPHW BA, BABBABRPBABRSPHQPQBGFQPGFQBAFQBAGQBHWQPHW

    BA, BABBABRPBABRSPHQPQBGFQPGFQBAFQBAGQBHWQPHWEHDFD

    BA, BABBABRPBABRSPHQPQBGFQPGFQBAFQBAGQBHWQPHWGB, GHBGHQEHDFDHFD

    BA, BABHQPQBGFQPGFQBAFQBAG

    150 FDB

    BA, BABHQPQBGFQBAFQBAG

    200 LA-P

    BA, BABHQPQBHWQPHWEHDFD

    225 EDB EDS ED, FD EDH, EDC HFD FDC FDC

    BA, BABBABRPBABRSPHQPQBGFQPGFQBHGFQPHGFQBHWQPHWQBAFQBAG

    BA, BABBABRPBABRSPHQPQBGFQPGFQBHGFQPHGFQBHWQPHWQBAFQBAG

    BA, BABBABRPBABRSPHQPQBGFQPGFQBAFQBAGQBHWQBHGF

    BA, BABBABRPBABRSPHQPQBGFQPGFQBAFQBAG

    BA, BABHQPQBGFQBAFQBAGQBHWQPHWQBHGFGB, GHBGHQ, GHQRSPEHDFD

    BA, BABHQPQBHWQPHW

    GB, GHBGHQGHQRSPEHDFDHFD

    250 JD, JDB HJD JDC HJD JDC JDC

    BA (15 70 A)BAB (15 70 A)HQP (15 70 A)QBHWQPHWEHD

    BA, BABHQPQBHWQPHW

    QBGFQPGFQBAFQBAG

    GB, GHBEHDFD

    BA, BABHQPQBHWQPHW

    GB, GHBEHDFDHFD

    400 DK, KD DK, KD HKD, CHKD DK, KD KDC HKD KDC KDC LCLKDB KDB, CKD BA (15 70 A)

    BAB (15 70 A)BABRPBABRSP

    HQP (15 70 A)QBHWQPHW

    KDB BA (15 70 A)BAB (15 70 A)HQP (15 70 A)

    CHKD QBHWQPHW

    GB, GHBEHDFDHFD

    BA, BABHQPQBGFQPGF

    QBAFQBAGQBHWQPHWGB, GHBEHDFDHFD

    BA, BABBABRPBABRSP

    HQPQBGFQPGFQBAFQBAG

    BA (15 70 A)BAB (15 70 A)BABRP

    BABRSPHQP (15 70 A)QBHWQPHW

    CKD GB, GHBEHDFD

    EHD

    600 CHLD, HLD

    EHD

    800 HMDL

    EHD

    1200 HND

    EHD

  • 7/13/2019 Tb 01400001 e

    14/89

    February 2007

    4-14

    For more information visit: www.eaton.com CA08101001E

    Panelboards

    4

    Pow-R-Line C Panelboards

    Technical Data and Specifications

    Table 14-7. 240 Volts ac Breaker/Breaker Series RatingsFor 1- and 2-pole 120/240 volt rated breakers (BA, BAB, HQP, QBHW, QPHW), see Table 14-6.Main devices are shown centered at top, in shaded area. Respective branch devices shown directly below.

    MainBreakerMaximumAmperes

    Series Equipment Rating kA Symmetrical

    18 22 42 65 100 200

    100 EHD QBHW_H GB, GHB FB-P FCL

    BAB_HHQP_H

    QPHW_H BAB_HHQP_HQBHW_HQPHW_H

    BAB_HHQP_HEHDFDBFD

    BAB_HHQP_HQBHW_HQPHW_HGB, GHBEHDFDFDBHFD

    BAB_HHQP_H

    150 FDB

    BAB_HHQP_H

    200 LA-P

    BAB_HHQP_H

    QBHW_HQPHW_HEHDFDBFDJD, JDB

    225 EDB EDS ED FD EDH, EDC HFD FDC FDC

    HQP_HBAB_HQBHWQPHW

    HQP_HBAB_HQBHWQPHW

    BAB_HHQP_HQBHW_H

    BAB_HHQP_HQBHW_HQPHW_HEHD (15 70 A)FDB

    BAB_HHQP_H

    BAB_HHQP_HQBHW_HQPHW_HGB, GHBEHDFDBFD

    BAB_HHQP_HQBHW_HQPHW_H

    GB, GHBEHDFDBFDHFD

    250 JD, JDB HJD HJD JDC JDC

    BAB_H (15 70 A)HQP_H (15 70 A)

    QBHW_HQPHW_HEHDFDB

    BAB_H (15 70 A)HQP_H (15 70 A)

    QBHW_HQPHW_H

    GB, GHBEHD

    FDFDBEDJD, JDB

    BAB_HHQP_H

    QBHW_HQPHW_H

    GB, GHBEHD

    FDFDBHFD, EDB, EDSEDEDHJD, JDBHJD

  • 7/13/2019 Tb 01400001 e

    15/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    14PanelboardsPow-R-Line C Panelboards

    Technical Data and Specifications

    Table 14-7. (Continued) 240 Volts ac Breaker/Breaker Series RatingsFor 1- and 2-pole 120/240 volt rated breakers (BA, BAB, HQP, QBHW, QPHW), see Table 14-6.Main devices are shown centered at top, in shaded area. Respective branch devices shown directly below.

    Valid on 2- and 3-pole breakers only. Not valid for 1-pole.

    MainBreakerMaximumAmperes

    Series Equipment Rating kA Symmetrical

    65 100 200

    400 DK, KD, KDB HKD, CHKD KDC KDC LCLCKD QBHW_H

    QPHW_H

    GB, GHBEHDFDBFD, EDB, EDSEDJD, JDBDK, KD, KDB

    QBHW_HQPHW_H

    GB, GHBEHDFDBFDHFD, EDB, EDSEDEDHJD, JDBHJDDK, KD, KDBHKD

    BAB_HHQP_HQBHW_HQPHW_HGB, GHBEHDFDBFD, HFD, EDB, EDSEDEDHJD, JDBHJDDK, KD, KDBHKD

    BAB_HHQP_HQBHW_HQPHW_HEHDFDB

    500 NB-P

    JD, JDB

    KD, KDB, DKCKD

    600 HLD, HLDB, CHLD LDC

    GB , GHB

    FD, EDB, EDSED, EHDJD, JDBKD, KDB, DK, CKDLD, LDB

    EDB, EDS, EDEDH

    800 NB-P HMDL

    KD, KDB, DK EHDFD

    1200 HND, CHND NDC

    EDB, EDS, EDEHD

    EDB, EDS, EDEDH

    2500 RD RDC

    EDB, EDS, ED EDB, EDS, EDEDH

  • 7/13/2019 Tb 01400001 e

    16/89

    February 2007

    4-16

    For more information visit: www.eaton.com CA08101001E

    Panelboards

    4

    Pow-R-Line C Panelboards

    Technical Data and Specifications

    Table 14-8. 277 Volts ac Breaker/Breaker Series RatingsMain devices are shown centered at top, in shaded area. Respective branch devices shown directly below.All ratings in this table apply to single-pole branch breakers only. For 2- and 3-pole branch breakers, see other tables.

    Table 14-9. 480Y/277 Volts ac Breaker/Breaker Series RatingsMain devices are shown centered at top, in shaded area. Respective branch devices shown directly below.All ratings in this table apply to 2- and 3-pole branch breakers only. For single-pole branch breakers, see Table 14-8.

    MainBreakerMaximumAmperes

    Series Equipment Rating kA Symmetrical

    22 25 35 65 100 150

    100 FCL

    GHBGHQ, GHQRSPEHDFDHFD

    225 FD HFD FDC

    GHBGHQGHQRSP

    GHB, GHQRSPGHQEHDFD

    GHBEHDFDHFD

    250 JD, JDB JD, JDB HJD LCL JDC

    GHB GHB (15 50 A) GHB (15 50 A)EHDFD

    GHBS GHBEHDFDHFD

    400 KD, KDB HKD KD, KDB HKD, CHKD KDC LCLCKD CHKD CKD GHB (15 50 A)

    EHDFD

    GHB (15 50 A)EHDFDHFD

    GHBEHDFDHFD

    GHB GHB GHB (15 50 A)EHDFD

    MainBreakerMaximumAmperes

    Series Equipment Rating kA Symmetrical

    22 25 35 65 100 150

    100 FCL

    GHB, GHQRSP

    225 FD HFD FDC

    GHB, GHQRSP GHB, GHQRSP GHB

    250 JD, JDB JD, JDB HJD JDC

    GHB GHB (15 50 A) GHB (15 50 A) GHB

    400 KD, KDB HKD, CHKD KD, KDB HKD, CHKD KDC LCLCKD GHB CKD GHB (15 50 A) GHB (15 50 A) GHB

    GHB GHB (15 50 A)

  • 7/13/2019 Tb 01400001 e

    17/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    14PanelboardsPow-R-Line C Panelboards

    Technical Data and Specifications

    Table 14-10. 480 Volts ac Breaker/Breaker Series RatingsMain devices are shown centered at top, in shaded area. Respective branch devices shown directly below.All ratings in this table apply to 2- and 3-pole branch breakers only. Not valid for 1-pole branch breakers.

    MainBreakerMaximumAmperes

    Series Equipment Rating kA Symmetrical

    25 35 65 100 150

    100 FB-P FCL

    EHDFDBFDHFD

    EHDFDBFDHFD

    200 LA-P

    EHDFDBFDHFDJD, JDBHJD

    225 FD HFD FDC

    EHDFDB

    EHDFDBFD

    EHDFDBFD

    HFD250 JD, JDB HJD JDC

    EHDFDB

    EHDFDBFDJD, JDB

    EHDFDBFDHFDJD, JDBHJD

    400 KD, KDB HKD KDC LA-P LCL

    EHDFDB

    EHDFDBFDJD, JDBKD, KDB

    EHDFDBFDHFDJD, JDBHJDKD, KDBHKD

    JD, JDBHJDKD, KDBHKD

    EHDFDBFDHFDFDCJD, JDBHJDKD, KDBHKD

    500 NB-P

    JD, JDBHJDKD, KDBHKD

    600 LD, LDB HLD, HLDBCLD CHLD

    JD, JDB FDJD, JDBKD, KDBLD, LDB

  • 7/13/2019 Tb 01400001 e

    18/89

    February 2007

    4-18

    For more information visit: www.eaton.com CA08101001E

    Panelboards

    4

    Pow-R-Line C Panelboards

    Technical Data and Specifications

    Table 14-11. 600 Volts ac Breaker/Breaker Series RatingsMain fuse class shown centered at top, in shaded area. Respective branch devices shown directly below.All ratings in this table apply to 2- and 3-pole branch breakers only. Not valid for 1-pole branch breakers.

    Table 14-12. 120/240 Volts ac Fuse/Breaker Series RatingsMain fuse class shown centered at top, in shaded area. Respective branch devices shown directly below.

    MainBreakerMaximumAmperes

    Series Equipment Rating kA Symmetrical

    18 25 35 42 50 100

    225 FD HFD FDC

    FDB FDBFD

    FDBFDHFD

    250 JD, JDB HJD JDC

    FDB FDBFDJD, JDB

    FDBFDHFDJD, JDBHJD

    400 KD, KDB HKD, CHKD KDC KDC LCLCKD FDB

    FDHFDJD, JDBHJD

    FDBFDHFD

    JD, JDBHJDKD, KDBHKD

    FDBFDHFDFDCJD, JDB

    HJDJDCKD, KDBHKDKDC

    FDBFDJD, JDB

    600 LD, LDB HLD, HLDBCLD CHLD

    FDJD, JDB

    KD, KDBLD, LDB

    MainFuseMaximumAmperes

    Series Equipment Rating kA Symmetrical

    100 200

    100 R

    BA, BABHQPQBHWQPHWGBGHB

    200 R J T

    GBGHB

    BA, BABHQPQBHWQPHW

    BA, BABHQPQBHWQPHW

    400 J T J T

    BA, BABHQPQBHWQPHW

    BA, BABHQPQBHWQPHW

    GBGHB

    GBGHB

  • 7/13/2019 Tb 01400001 e

    19/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    14PanelboardsPow-R-Line C Panelboards

    Technical Data and Specifications

    Table 14-13. 240 Volts ac Fuse/Breaker Series RatingsFor 1- and 2-pole 120/240 volt rated breakers (BA, BAB, HQP, QBHW, QPHW), see Table 14-12.Main fuse class shown centered at top, in shaded area. Respective branch devices shown directly below.

    Valid on 2- and 3-pole breakers only. Not valid for 1-pole.

    Table 14-14. 277 Volts ac Fuse/Breaker Series RatingsMain fuse class are shown centered at top, in shaded area. Respective branch devices shown directly below.All ratings in this table apply to single-pole branch breakers only. For 2- and 3-pole branch breakers, consult other tables.

    MainFuseMaximumAmperes

    Series Equipment Rating kA Symmetrical

    100 200

    100 R

    BAB_HHQP_HQBHW_HQPHW_HGBGHB

    200 R J T R

    GBGHB

    BAB_HHQP_HQBHW_HQPHW_H

    BAB_HHQP_HQBHW_HQPHW_H

    GB

    GHB

    400 J T J T

    BAB_HHQP_HQBHW_H

    QPHW_H

    BAB_HHQP_HQBHW_H

    QPHW_H

    GBGHB

    GBGHB

    600 L

    EHDFDBFDEDJD, JDBDK, KD, KDB

    MainFuseMaximumAmperes

    Series Equipment Rating kA Symmetrical

    65 100 200

    100 J T R

    GHBSGHQGHQRSP

    GHBSGHQGHQRSP

    GHB

    200 J T J T R

    GHBSGHQGHQRSP

    GHBSGHQGHQRSP

    EHDFDHFD

    EHDFDHFD

    GHB

    400 J T

    GHB GHB

  • 7/13/2019 Tb 01400001 e

    20/89

    February 2007

    4-20

    For more information visit: www.eaton.com CA08101001E

    Panelboards

    4

    Pow-R-Line C Panelboards

    Technical Data and Specifications

    Table 14-15. 480Y/277 Volts ac Fuse/Breaker Series RatingsMain fuse class shown centered at top, in shaded area.Respective branch devices shown directly below. All ratingsin this table apply to 2- and 3-pole branch breakers only.For single-pole branch breakers, see Table 14-14.

    Table 14-16. 480 Volts ac Fuse/Breaker Series RatingsMain fuse class shown centered at top, in shaded area.Respective branch devices shown directly below. All ratingsin this table apply to 2- and 3-pole branch breakers only.Not valid for single-pole branch breakers.

    Table 14-17. 600 Volts ac Fuse/Breaker Series RatingsMain fuse class shown centered at top, in shaded area.Respective branch devices shown directly below. All ratingsin this table apply to 2- and 3-pole branch breakers only.Not valid for single-pole branch breakers.

    Table 14-18. Triple Series Ratings

    Valid on 2- and 3-pole breakers only. Not valid for single-pole.

    Main

    FuseMaximumAmperes

    Series Equipment Rating kA Symmetrical

    65 100 200

    100 J T R

    GHBS GHBS GHB

    200 J T R

    GHBS GHBS GHB

    400 J T

    GHB GHB

    600 J T

    EHDFDHFDFDC

    GHBEHDFDHFDFDCJD

    HJDJDC

    MainFuseMaximumAmperes

    Series Equipment Rating kA Symmetrical

    100 200

    100 R

    EHD

    200 J T

    EHD

    FDHFDFDC

    EHD

    FDHFDFDC

    Main

    FuseMaximumAmperes

    Series Equipment Rating kA Symmetrical

    100 200

    100 R

    FDHFDFDC

    200 J T R

    FDHFDFDC

    FDHFDFDC

    JDHJDJDC

    400 J T R

    JDHJDJDC

    JDHJDJDC

    KDHKDKDC

    600 J T

    KDHKDKDC

    KDHKDKDC

    Main FuseClass andMaximumAmperes

    Tenant MainType

    BranchType

    SystemVoltage

    ShortCircuitSeriesRating(kA, Sym.)

    L-6000 DK, KD, KDB GB, GHB, EHD 240 100

    L-6000 DK, KD, KDB GB, GHB 120/240 100

    L-6000 DK, KD, KDB FD , FDB 240 100

    L-6000 DK, KD, KDB JD, JDB 240 100

    L-6000 JD, JDB GB, GHB 240 100

    L-6000 JD, JDB GB, GHB 120/240 100

    L-6000 FD GB, GHB 240 100

    L-6000 FD GB, GHB 120/240 100

    L-6000 FD, FDB BAB_H, HQP_HQBHW_H, QPHW_H

    240 100

    L-6000 FD, FDB BA, BABHQP (15 70A)

    120/240 100

    L-6000 EHD BAB_H, HQP_H 240 100

    L-6000 EHD BA, BAB, HQP 120/240 100

  • 7/13/2019 Tb 01400001 e

    21/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    14PanelboardsPow-R-Line C Panelboards

    PRL1a

    Product Description

    240 Vac maximum.

    3-phase 4-wire, 3-phase 3-wire,1-phase 3-wire, 1-phase 2-wire.

    400 ampere maximum mains.

    100 ampere maximum branchbreakers.

    Bolt-on or plug-on branch breakers.

    Factory assembled.

    Refer to Page 14-5for additionalinformation.

    Type PRL1a

    Application Description Lighting and appliance branch

    panelboard.

    Fully rated or series rated.

    Interrupting ratings up to 200 kAsymmetrical.

    Suitable for use as Service EntranceEquipment, when specified onthe order.

    See Pages 14-5through14-18foradditional information.

    Standards and Certifications

    UL 67, UL 50. Federal Specification W-P-115c.

    Refer to Page 14-5for additionalinformation.

    Options and Accessories

    Refer to Page 14-46.

    Layout and Sizing Refer to Page 14-22.

    Product Selection

    Formula Pricing: Base Price + Branch Circuits + Modifications = Total Price U.S. $

    Table 14-19. Base Prices PRL1a

    Table 14-20. Branch Circuit Breakers PRL1a

    1-pole breakers are rated 120 Vac maximum. 240 volt breakers must be used on 3-phase, 3-wire, 240 volt delta systems or on the high leg of a

    midpoint delta grounded system. 50 ampere devices are available as 2-pole only. GFCI for 5 mA personnel protection. GFP for 30 mA equipment protection. Arc fault circuit breaker. Arc fault circuit breaker with GFCI. HID (High Intensity Discharge) rated breaker. Switching Neutral Breaker. 1-pole device requires 2-pole space, 2-pole device requires 3-pole space. Solenoid operated breaker.

    AmpereRating

    InterruptingRating (kA Sym.)

    240 Vac

    BreakerType

    Price U.S. $

    3-Phase

    4-Wire

    1-Phase 3-Wire,

    1-Phase 2-Wire

    3-Phase

    3-Wire

    Main Lug Only

    100225400

    Main Breaker

    100100100100100100100100100

    10 18 22 22 42 65 65100100

    BABEHDQBHWEDBEDSEDFDEDHHFD

    225225

    225225

    22 42

    65100

    EDBEDS

    EDEDH

    250250250

    65100200

    JDHJDJDC

    400400400400

    65 65100200

    DKKDHKDKDC

    Bolt-on = BAB, QBHW, QBGF, QBHGF, QBGFEP, QBHGFEP, QBAF, QBAG, QBHAF, QBHAGPlug-on = HQP, QPHW, QPGF, QPHGF, QPGFEP, QPHGFEP

    AmpereRating

    InterruptingRating (kA Sym.)240 Vac

    BreakerType

    Price U.S. $

    1-Pole120 V

    2-Pole120/240 V

    2-Pole240 V

    3-Pole240 V

    15 607080 10015 50

    15 50

    15 2015 20

    10101010101010

    BAB, HQPBAB, HQPBAB, HQPQBGF, QPGF

    QBGFEP, QPGFEP

    QBAF

    QBAG

    15 6015 3015 3015 30

    10101010

    BAB-D, HQP-D

    BAB-C, HQP-B

    BABRP

    BABRSP

    15 607080 10015 3015 3015 2015 20

    22222222222222

    QBHW, QPHWQBHW, QPHWQBHW, QPHWQBHGF, QPHGF

    QBHGFEP, QPHGFEP

    QBHAF

    QBHAG

    Provision

    Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . CE9

  • 7/13/2019 Tb 01400001 e

    22/89

    February 2007

    4-22

    For more information visit: www.eaton.com CA08101001E

    Panelboards

    4

    Pow-R-Line C Panelboards

    PRL1a

    Box Sizing and Selection

    Assembled Circuit Breaker Panelboards

    Box size and box and trim catalognumbers for all standard panelboardtypes are found in Table 14-21.

    Instructions1. Using description of the required

    panelboard, select the rating andtype of main required.

    2. Count the total number of branchcircuit poles, including provisions,required in the panelboard. Do notcount main breaker poles. Convert2- or 3-pole branch breaker tosingle-poles, i.e., 3-pole breaker,count as 3 poles.

    Determine sub-feed breaker orthrough-feed lug requirements.

    3. Select the main ampere ratingsection from Table 14-21.

    4. Select panelboard type from firstcolumn, main breaker frame, ifapplicable, from second column,and sub-feed breaker frame, ifapplicable, from the third column.

    5. From Step #2, determine the num-ber of branch circuits in Column 4.

    6. Read box size, box and trimcatalog numbers across columnsto the right. Specify surface orflush mounting on the order.

    CabinetsFronts are code-gauge steel, ANSI-61light gray painted finish.

    Boxes are code-gauge galvanized steel

    without knockouts. Standard depth is5-3/4 inches (146.1 mm). Standardwidth is 20 inches (508.0 mm). Anoptional 28-inch (711.2 mm) widebox is available.

    Top and Bottom Gutters

    5-1/2 inches (139.7 mm) minimum.

    Table 14-21. PRL1a Panelboard Sizing

    Metric box dimensions:

    Smaller panelboard box sizes are available if required. Contact Eaton for application information.

    PanelboardTypes

    Main Breaker Types& Mounting Position(H) = Horiz.(V) = Vert.

    Sub-Feed Breaker Types& Mounting Position(H) = Horiz.(V) = Vert.

    Maximum No. ofBranch CircuitsIncludingProvisions

    Box DimensionsInches

    YS BoxCatalogNumber

    LT TrimCatalogNumber

    EZ BoxCatalogNumber

    EZ TrimCatalogNumber

    H W D

    100 Ampere Maximum

    Main Breaker BAB, QBHW(H)

    15273942

    36.0048.0048.0060.00

    20.0020.0020.0020.00

    5.755.755.755.75

    YS2036YS2048YS2048YS2060

    LT2036S or FLT2048S or FLT2048S or FLT2060S or F

    EZB2036REZB2048REZB2048REZB2060R

    EZT2036S or FEZT2048S or FEZT2048S or FEZT2060S or F

    Main Lugs orMain Breaker

    EHDFD, HFD(V)

    183042

    36.0048.0048.00

    20.0020.0020.00

    5.755.755.75

    YS2036YS2048YS2048

    LT2036S or FLT2048S or FLT2048S or F

    EZB2036REZB2048REZB2048R

    EZT2036S or FEZT2048S or FEZT2048S or F

    Main Lugs or MainBreaker with 100 AThru-Feed Lugs orSub- Feed Breaker

    EHDFDHFD(V)

    EHDFDHFD(V)

    183042

    48.0048.0060.00

    20.0020.0020.00

    5.755.755.75

    YS2048YS2048YS2060

    LT2048S or FLT2048S or FLT2060S or F

    EZB2048REZB2048REZB2060R

    EZT2048S or FEZT2048S or FEZT2060S or F

    225 Ampere Maximum

    Main Lugs orMain Breaker

    EDB, EDS, ED,EDH, FD, HFD(V)

    183042

    36.0048.0048.00

    20.0020.0020.00

    5.755.755.75

    YS2036YS2048YS2048

    LT2036S or FLT2048S or FLT2048S or F

    EZB2036REZB2048REZB2048R

    EZT2036S or FEZT2048S or FEZT2048S or F

    JD, HJDJDC(V)

    183042

    60.0060.0072.00

    20.0020.0020.00

    5.755.755.75

    YS2060YS2060YS2072

    LT2060S or FLT2060S or FLT2072S or F

    EZB2060REZB2060REZB2072R

    EZT2060S or FEZT2060S or FEZT2072S or F

    Main Lugs orMain Breaker with225 A Thru-FeedLugs or Sub-FeedBreaker

    EHD, FD, HFD,EDB, EDS, ED,EDH (V)

    EHD, FD, HFD,EDB, EDS, ED,EDH (V)

    183042

    48.0048.0060.00

    20.0020.0020.00

    5.755.755.75

    YS2048YS2048YS2060

    LT2048S or FLT2048S or FLT2060S or F

    EZB2048REZB2048REZB2060R

    EZT2048S or FEZT2048S or FEZT2060S or F

    JD, HJDJDC(V)

    EHD, FD, HFD,EDB, EDS, ED,EDH (V)

    183042

    60.0072.0072.00

    20.0020.0020.00

    5.755.755.75

    YS2060YS2072YS2072

    LT2060S or FLT2072S or FLT2072S or F

    EZB2060REZB2072REZB2072R

    EZT2060S or FEZT2072S or FEZT2072S or F

    400 Ampere Maximum

    Main Lugs orMain Breaker

    DK, KD, HKD,KDC(V)

    183042

    60.0060.0072.00

    20.0020.0020.00

    5.755.755.75

    YS2060YS2060YS2072

    LT2060S or FLT2060S or FLT2072S or F

    EZB2060REZB2060REZB2072R

    EZT2060S or FEZT2060S or FEZT2072S or F

    Main Lugs orMain Breaker with225 A Thru-FeedLugs or Sub- FeedBreaker

    DK, KD, HKD,KDC(V)

    EHD, FD, HFD,EDB, EDS, ED,EDH (V)

    183042

    60.0072.0072.00

    20.0020.0020.00

    5.755.755.75

    YS2060YS2072YS2072

    LT2060S or FLT2072S or FLT2072S or F

    EZB2060REZB2072REZB2072R

    EZT2060S or FEZT2072S or FEZT2072S or F

    Main Lugs orMain Breaker with400 A Thru-FeedLugs or Sub- FeedBreaker

    DK, KD, HKD,KDC(V)

    JD, HJD, JDC,DK, KD,HKD, KDC(V)

    183042

    72.0090.0090.00

    20.0020.0020.00

    5.755.755.75

    YS2072YS2090YS2090

    LT2072S or FLT2090S or FLT2090S or F

    EZB2072REZB2090REZB2090R

    EZT2072S or FEZT2090S or FEZT2090S or F

    Catalog Number Dimensions in mm

    YS Box EZ Box Height Width Depth

    YS2036YS2048YS2060YS2072YS2090

    EZB2036REZB2048REZB2060REZB2072REZB2090R

    914.41219.21524.01828.82286.0

    508.0508.0508.0508.0508.0

    146.1146.1146.1146.1146.1

  • 7/13/2019 Tb 01400001 e

    23/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    14PanelboardsPow-R-Line C Panelboards

    PRL2a

    Product Description

    480Y/277 Vac maximum (125 Vdc).

    3-phase 4-wire, 3-phase 3-wire,1-phase 3-wire, 1-phase 2-wire.

    400 ampere maximum mains.

    100 ampere maximum branchbreakers.

    Bolt-on branch breakers.

    Factory assembled.

    Refer to Page 14-5for additionalInformation.

    Type PRL2a

    Application Description

    Lighting and appliance branchpanelboard.

    Fully rated or series rated.

    Interrupting ratings up to 200 kAsymmetrical.

    Suitable for use as Service EntranceEquipment, when specified onthe order.

    See Pages 14-5 through14-18foradditional information.

    Standards and Certifications

    UL 67, UL 50.

    Federal Specification W-P-115c.

    Refer to Page 14-5for additionalinformation.

    Options and Accessories

    Refer to Page 14-46.

    Layout and Sizing Refer to Page 14-24.

    Product Selection

    Formula Pricing: Base Price + Branch Circuits + Modifications = Total Price U.S. $

    Table 14-22. Base Prices PRL2a

    These system voltages apply only to 240 volts.

    Table 14-23. Branch Circuit Breakers PRL2a

    Interrupting ratings in this column are applicable to 120 Vac for 1-pole breakers. At 480 volts, must be used on 480Y/277 volts grounded wye systems only. Solenoid operated breaker. GFP for 30 mA equipment protection. Requires 2-pole spaces. 277 Vac only. HID (High Intensity Discharge) rated breaker.

    AmpereRating

    Interrupting Rating(kA Symmetrical)

    BreakerType

    Price U.S. $

    240 Vac 480Y/277 Vac 125/250 Vdc 3-Phase4-Wire

    1-Phase 3-Wire,1-Phase 2-Wire

    3-Phase3-Wire

    Main Lug Only

    100225400

    Main Breaker

    100100

    65 18

    14 14

    1410

    GHBEHD

    100100100

    65100200

    35 65100

    102222

    FDHFDFDC

    225225225225

    65 65100200

    35 65100

    102222

    EDFDHFDFDC

    250250250

    65100200

    35 65100

    102222

    JDHJDJDC

    400400400

    65100200

    35 65100

    102222

    KDHKDKDC

    AmpereRating

    Interrupting Rating(kA Symmetrical)

    BreakerType

    Price U.S. $

    240 Vac 480Y/277 Vac 125/250 Vdc 1-Pole 2-Pole 3-Pole

    15 2015 2025 6070 100

    15 3015 2015 30

    65656565

    656565

    14141414

    251414

    141414

    GHQ

    GHB

    GHB

    GHB

    HGHB

    GHQRSP

    GHBS

    15 6015 20

    1414

    GHBGFEP

    GHBHID

    Provision

    Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . CE9

  • 7/13/2019 Tb 01400001 e

    24/89

    February 2007

    4-24

    For more information visit: www.eaton.com CA08101001E

    Panelboards

    4

    Pow-R-Line C Panelboards

    PRL2a

    Box Sizing and Selection

    Assembled Circuit Breaker Panelboards

    Box size and box and trim catalognumbers for all standard panelboardtypes are found in Table 14-24.

    Instructions1. Using description of the required

    panelboard, select the rating andtype of main required.

    2. Count the total number of branchcircuit poles, including provisions,required in the panelboard. Do notcount main breaker poles. Convert2- or 3-pole branch breaker tosingle-poles, i.e., 3-pole breaker,count as 3 poles.

    Determine sub-feed breaker orthrough-feed lug requirements.

    3. Select the main ampere ratingsection from Table 14-24.

    4. Select panelboard type from firstcolumn, main breaker frame, ifapplicable, from second column,and sub-feed breaker frame, ifapplicable, from the third column.

    5. From Step #2, determine the num-ber of branch circuits in Column 4.

    6. Read box size, box and trimcatalog numbers across columnsto the right. Specify surface orflush mounting on the order.

    Cabinets

    Fronts are code-gauge steel, ANSI-61light gray painted finish.

    Boxes are code-gauge galvanized steel

    without knockouts. Standard depth is5-3/4 inches (146.1 mm). Standardwidth is 20 inches (508.0 mm). Anoptional 28-inch (711.2 mm) widebox is available.

    Top and Bottom Gutters

    5-1/2 inches (139.7 mm) minimum.

    Table 14-24. PRL2a Panelboard Sizing

    Metric box dimensions:

    Smaller panelboard box sizes are available if required. Contact Eaton for application information.

    PanelboardTypes

    Main Breaker Types& Mounting Position(H) = Horiz.

    (V) = Vert.

    Sub-Feed Breaker Types& Mounting Position(H) = Horiz.

    (V) = Vert.

    Maximum No. ofBranch CircuitsIncluding

    Provisions

    Box DimensionsInches YS BoxCatalog

    Number

    LT TrimCatalogNumber

    EZ BoxCatalogNumber

    EZ TrimCatalogNumberH W D

    100 Ampere Maximum

    Main Breaker BAB, QBHW(H)

    15273942

    36.0048.0048.0060.00

    20.0020.0020.0020.00

    5.755.755.755.75

    YS2036YS2048YS2048YS2060

    LT2036S or FLT2048S or FLT2048S or FLT2060S or F

    EZB2036REZB2048REZB2048REZB2060R

    EZT2036S or FEZT2048S or FEZT2048S or FEZT2060S or F

    Main Lugs orMain Breaker

    EHDFD, HFD(V)

    183042

    36.0048.0048.00

    20.0020.0020.00

    5.755.755.75

    YS2036YS2048YS2048

    LT2036S or FLT2048S or FLT2048S or F

    EZB2036REZB2048REZB2048R

    EZT2036S or FEZT2048S or FEZT2048S or F

    Main Lugs or MainBreaker with 100 AThru-Feed Lugs orSub- Feed Breaker

    EHDFDHFD(V)

    EHDFDHFD(V)

    183042

    48.0048.0060.00

    20.0020.0020.00

    5.755.755.75

    YS2048YS2048YS2060

    LT2048S or FLT2048S or FLT2060S or F

    EZB2048REZB2048REZB2060R

    EZT2048S or FEZT2048S or FEZT2060S or F

    225 Ampere Maximum

    Main Lugs orMain Breaker

    EDB, EDS, ED,EDH, FD, HFD(V)

    183042

    36.0048.0048.00

    20.0020.0020.00

    5.755.755.75

    YS2036YS2048YS2048

    LT2036S or FLT2048S or FLT2048S or F

    EZB2036REZB2048REZB2048R

    EZT2036S or FEZT2048S or FEZT2048S or F

    JD, HJDJDC(V)

    183042

    60.0060.0072.00

    20.0020.0020.00

    5.755.755.75

    YS2060YS2060YS2072

    LT2060S or FLT2060S or FLT2072S or F

    EZB2060REZB2060REZB2072R

    EZT2060S or FEZT2060S or FEZT2072S or F

    Main Lugs or MainBreaker with 225 AThru-Feed Lugs orSub-Feed Breaker

    EHD, FD, HFD,EDB, EDS, ED,EDH (V)

    EHD, FD, HFD,EDB, EDS, ED,EDH (V)

    183042

    48.0048.0060.00

    20.0020.0020.00

    5.755.755.75

    YS2048YS2048YS2060

    LT2048S or FLT2048S or FLT2060S or F

    EZB2048REZB2048REZB2060R

    EZT2048S or FEZT2048S or FEZT2060S or F

    JD, HJDJDC(V)

    EHD, FD, HFD,EDB, EDS, ED,EDH (V)

    183042

    60.0072.0072.00

    20.0020.0020.00

    5.755.755.75

    YS2060YS2072YS2072

    LT2060S or FLT2072S or FLT2072S or F

    EZB2060REZB2072REZB2072R

    EZT2060S or FEZT2072S or FEZT2072S or F

    400 Ampere Maximum

    Main Lugs orMain Breaker

    DK, KD, HKD,KDC(V)

    183042

    60.0060.0072.00

    20.0020.0020.00

    5.755.755.75

    YS2060YS2060YS2072

    LT2060S or FLT2060S or FLT2072S or F

    EZB2060REZB2060REZB2072R

    EZT2060S or FEZT2060S or FEZT2072S or F

    Main Lugs or MainBreaker with 225 AThru-Feed Lugs orSub- Feed Breaker

    DK, KD, HKD,KDC(V)

    EHD, FD, HFD,EDB, EDS, ED,EDH (V)

    183042

    60.0072.0072.00

    20.0020.0020.00

    5.755.755.75

    YS2060YS2072YS2072

    LT2060S or FLT2072S or FLT2072S or F

    EZB2060REZB2072REZB2072R

    EZT2060S or FEZT2072S or FEZT2072S or F

    Main Lugs or MainBreaker with 400 AThru-Feed Lugs orSub- Feed Breaker

    DK, KD, HKD,KDC(V)

    JD, HJD, JDC,DK, KD,HKD, KDC(V)

    183042

    72.0090.0090.00

    20.0020.0020.00

    5.755.755.75

    YS2072YS2090YS2090

    LT2072S or FLT2090S or FLT2090S or F

    EZB2072REZB2090REZB2090R

    EZT2072S or FEZT2090S or FEZT2090S or F

    Catalog Number Dimensions in mm

    YS Box EZ Box Height Width Depth

    YS2036YS2048YS2060YS2072YS2090

    EZB2036REZB2048REZB2060REZB2072REZB2090R

    914.41219.21524.01828.82286.0

    508.0508.0508.0508.0508.0

    146.1146.1146.1146.1146.1

  • 7/13/2019 Tb 01400001 e

    25/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    14PanelboardsPow-R-Line C Panelboards

    PRL3a

    Product Description

    600 Vac maximum (250 Vdc).

    3-phase 4-wire, 3-phase 3-wire,1-phase 3-wire, 1-phase 2-wire.

    800 ampere maximum main lugs.

    600 ampere maximum mainbreaker.

    225 ampere maximum branchbreakers.

    Bolt-on branch breakers.

    Factory assembled.

    Refer to Page 14-5for additionalinformation.

    Type PRL3a

    Application Description

    Lighting and appliance branchpanelboard or power distributionpanelboard.

    Fully rated or series rated.

    Interrupting ratings up to 200 kAsymmetrical.

    Suitable for use as Service EntranceEquipment, when specified onthe order.

    See Pages 14-5 through14-18foradditional information.

    Standards and Certification

    UL 67, UL 50.

    Federal Specification W-P-115c.

    Refer to Page 14-5for additional

    information.

    Options and Accessories

    Refer to Page 14-46.

    Layout and Sizing Refer to Page 14-27.

    Product Selection

    Formula Pricing: Base Price + Branch Circuits + Modifications = Total Price U.S. $

    Table 14-25. Base Prices PRL3a

    800 ampere MLO requires 28-inch (711.2 mm) wide box. 100,000 based on NEMA test procedure. Top feed only. Requires 6-1/2-inch (165.1 mm) deep box. Not available in Type 3R, 12, 4 and 4X enclosures. 100% rated circuit breaker. Requires copper bus. Not available in Type 12, 4 and 4X enclosures.

    AmpereRating

    Interrupting Rating (kA Symmetrical) BreakerType

    Price U.S. $

    240 Vac 480 Vac 600 Vac 250 Vdc 3-Phase

    4-Wire

    1-Phase 3-Wire,

    1-Phase 2-Wire

    3-Phase

    3-Wire

    Main Lug Only

    100250400600800

    Main Breaker

    100100100100100100100100100

    100100

    18 18 22 42 65100 65100200

    200200

    14 14 35 65100

    150200

    14 18 25 35

    200

    10 10 10 22 22

    100

    EHDFDBEDBEDSEDEDHFDHFDFDC

    FCLFB-P

    225225225225225225225225

    22 42 65100200 65100200

    35 65100

    18 25 35

    10 22 22

    EDBEDSEDEDHEDCFDHFDFDC

    250250250

    65100200

    35 65100

    18 25 35

    10 22 22

    JDHJDJDC

    400400400400400

    400

    65 65100200200

    200

    35 65100200

    200

    25 35 65

    200

    10 10 22 22

    100

    DKKDHKDKDCLCL

    LA-P600600600600600600600600

    65100 65100200 65100200

    35 65 35 65100 35 65100

    18 35 25 35 50 25 35 50

    22 22 22 25 25 22 25 25

    LGELGHLDHLDLDCCLD

    CHLD

    CLDC

    Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . CE9

  • 7/13/2019 Tb 01400001 e

    26/89

    February 2007

    4-26

    For more information visit: www.eaton.com CA08101001E

    Panelboards

    4

    Pow-R-Line C Panelboards

    PRL3a

    Table 14-26. Branch Circuit Breakers PRL3a

    50 ampere devices are available as 2-pole only. 1-pole breaker rated 120 Vac. 2-pole breaker rated 120/240 Vac.

    Arc fault circuit breaker. Arc fault circuit breaker with GFCI. HID (High Intensity Discharge) rated breaker. Switching Neutral Breaker. 1-pole device requires 2-pole space, 2-pole device requires 3-pole space. Solenoid operated breaker. 1-pole breaker rated 277 Vac. For use on 480Y/277 volt systems only. AIC rating for 2- and 3-pole breakers only. Maximum of six breakers per panel, 175 225 amperes.

    AmpereRating

    Interrupting Rating (kA Symmetrical ) BreakerType

    Price U.S. $

    240 Vac 480 Vac 600 Vac 250 Vdc Breaker Space Only Provision Only

    1-Pole 2-Pole 3-Pole 1-Pole 2-Pole 3-Pole 1-Pole 2-Pole 3-Pole

    15 60 15 60 70 70 80 100 80 100 15 50

    15 50

    15 20 15 20 15 60 15 30 15 30 15 30

    10

    10 10

    10 10

    10 10

    10 10

    10

    10

    10

    10

    10

    BABBAB-HBABBAB-HBABBAB-HQBGFQBGFEPQBAF

    QBAG

    BAB-D

    BAB-C

    BABRP

    BABRSP

    15 60 15 60 70 70 80 100 80 100

    15 30 15 30 15 20 15 20

    22

    22 22

    22 22

    22

    22 22 22

    22

    QBHWQBHW-HQBHWQBHW-HQBHWQBHW-H

    QBHGFQBHGFEPQBHAF

    QBHAG

    15 20 15 20 25 60 70 100 15 30 15 20 15 30 15 60 15 20

    65 65 65 65 65 65 65

    14

    14

    14

    14

    25

    14

    14

    14

    14

    1414141414

    GHQGHBGHBGHBHGHBGHQRSP

    GHBS

    GHBGFEPGHBHID

    15 60 70 100

    18

    18 14

    14

    1010

    EHDEHD

    15 60 70 100110 150

    18 18 18

    V14 14 14

    141414

    101010

    FDBFDBFDB

    15 60 70 100110 225

    65 65

    65

    35 35

    35

    181818

    101010

    FDFDFD

    15 60 70 100110 225

    100

    100

    100

    65

    65

    65

    252525

    222222

    HFDHFDHFD

    15 60 70 100110 225

    200200200

    100100100

    353535

    222222

    FDCFDCFDC

    100 225100 225100 225100 225100 225

    22 42 65100200

    EDB

    EDS

    ED

    EDH

    EDC

    Discount Symbol. . . . . . . . . . . . . . . . . . . . . . . . . . . CE9

  • 7/13/2019 Tb 01400001 e

    27/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    14PanelboardsPow-R-Line C Panelboards

    PRL3a

    Figure 14-4. PRL3a Layout GHB, HGHB and GHQ breakers cannot be

    mixed on same connector as BAB, QBHW,BABRP and BABRSP.

    Maximum of six breakers per panel. Horizontal mounted 15 150 ampere mainbreakers EHD, FDB, FD, HFD and FDC, willbe furnished as branch breaker construction.Branch breakers 1-, 2- or 3-pole as required,may be located opposite these main breakers.

    If optional terminal kit 3TA225FDK isrequired, use 10X.

    FB-P and LA-P top mounting only. LCL or LA-P main breaker requires 6-1/2-inch

    (165.1 mm) deep box.

    Poles BAB, QBHW,

    BABRP,BABRSP

    GHQ, GHB,HGHB

    6 - 3X

    12 - 5X

    18 - 8X

    24 - 10X

    30 - 13X

    36 - 15X

    42 - 18X

    1X

    2X

    3X

    EDB, EDS, ED,EDH, EDC,EHD, FDB, FD,HFD, FDC150 A Max. PerBranch Breaker(300 A Max. PerConnector)

    2X2-Pole

    EDB, EDS, ED,EDH, EDCFD, HFD, FDC

    3X3-Pole

    Neutral

    Section

    5X 100 250 A

    8X 400 800 A

    11X 800A withThru-feed Lug

    Main LugSection

    2X 100 A

    5X 250 A

    8X 400 600 A

    14X 800 A

    MainBreakerSection

    Hori-zontalMount-ing

    2X2-Pole

    EHD, FDB, FD,HFD, FDC

    3X3-Pole

    EDB, EDS, ED,EDH, EDC

    VerticalMount-ing

    7X EHD, FDB, FD,HFD, FDC, EDB,EDS, ED, EDH,EDC

    9X FCL, FB-P

    14X JDHJD, JDC

    15X DK, KDHKD, KDC

    17X LD, HLD, LDCCLD, CHLD,CLDC

    18X LGE, LGH

    21X LCL, LA-P

    1-Pole

    2-Pole

    1-Pole

    2-Pole

    1-Pole

    2-Pole

    3-Pole

    2- or 3-Pole

    Panel Layout Instructions1. Select:

    a. Required mains (lugs orbreaker).

    b. Neutral where required.

    c. Branch circuits as required.

    2. Layout panel as shown inFigure 14-4, using appropriateX dimensions.

    3. Using total X units (panel height)find box height in inches (mm)and box catalog number fromTable 14-27. (When total X unitscome out to an uneven number,use next highest number; i.e., iftotal X comes out 25X, use 31X.)

    Layout Example1. Description of Panel

    Type PRL3a 3-phase, 4-wire,120/208 Vac flush mounting. Panelto have short circuit rating of22,000 symmetrical amperes.

    Main breaker 400 amperes, 3-pole,bottom mounting. Branch circuitsbolt-on as follows:

    12 20 ampere 1-pole QBHW1 200 ampere 3-pole ED1 225 ampere 3-pole ED

    2. Layout Information fromFigure 14-4:

    a. 400 ampere Neutral . . . . . . = 8X

    b. 12-poles of QBHW . . . . . . . = 5X

    c. Two 3-pole ED breakers . . . .= 6X

    d. Main breaker, 400 amperes,3-pole DK . . . . . . . . . . . . . = 15X

    Total Height . . . . . . . . . . . = 34X

    3. From Table 14-27:

    a. 34X Height (use 40X box)

    b. Box Height . . . . . . . . . 72 inches(1828.8 mm)

    c. Box Catalog Number. . . . YS2072. . . . . . . . . . . . . . . . or EZB2072R

    Table 14-27. Box Tabulation PRL3a

    Cabinets

    Fronts are code-gauge steel, ANSI-61

    light gray painted finish.Boxes are code-gauge galvanized steelwithout knockouts. Standarddepth is 5-3/4 inches (146.1 mm).

    Standard widths are:

    20-inch (508.0 mm) 100 600 amperes.28-inch (711.2 mm) 800 amperes.

    Standard Depth

    5-3/4 inches (146.1 mm).

    Top and Bottom Gutters

    5-1/2 inches (139.7 mm) minimum.

    Side Gutters

    4 inches (101.6 mm) minimum.

    XUnits

    Box Height YS BoxCatalogNumber

    LT TrimCatalogNumber

    EZ BoxCatalogNumber

    EZ TrimCatalogNumber

    Inches mm

    100 400 Amperes

    14X23X31X40X53X

    3648607290

    914.41219.21524.01828.82286.0

    YS2036YS2048YS2060YS2072YS2090

    LT2036S or FLT2048S or FLT2060S or FLT2072S or FLT2090S or F

    EZB2036REZB2048REZB2060REZB2072REZB2090R

    EZT2036S or FEZT2048S or FEZT2060S or FEZT2072S or FEZT2090S or F

    600 Amperes

    23X31X40X53X

    48607290

    1219.21524.01828.82286.0

    YS2048YS2060YS2072YS2090

    LTV2048S or FLTV2060S or FLTV2072S or FLTV2090S or F

    EZB2048REZB2060REZB2072REZB2090R

    EZTV2048S or FEZTV2060S or FEZTV2072S or FEZTV2090S or F

    800 Amperes

    23X31X40X53X

    48607290

    1219.21524.01828.82286.0

    YS2848YS2860YS2872YS2890

    LTV2848S or FLTV2860S or FLTV2872S or FLTV2890S or F

  • 7/13/2019 Tb 01400001 e

    28/89

    February 2007

    4-28

    For more information visit: www.eaton.com CA08101001E

    Panelboards

    4

    Pow-R-Line C Panelboards

    PRL4

    Type PRL4

    Type PRL4B Circuit Breaker Panelboard

    Product Description

    600 Vac maximum (250 Vdc).

    3-phase 4-wire, 3-phase 3-wire,1-phase 3-wire, 1-phase 2-wire.

    PRL4B circuit breaker panelboard.

    PRL4F fusible switch panelboard.

    1200 ampere maximum mains.

    1200 ampere maximum branchdevices.

    Bolt-on branch devices.

    Factory assembled.

    Refer to Page 14-5for additionalinformation.

    Type PRL4F Fusible Panelboard

    Application Description

    Power distribution panelboard.

    Fully rated or series rated.

    Interrupting ratings up to 200 kAsymmetrical.

    Suitable for use as Service EntranceEquipment, when specified onthe order.

    See Pages 14-5 through14-18foradditional information.

    Standards and Certifications

    UL 67, UL 50.

    Federal Specification W-P-115c.

    Refer to Page 14-5for additionalinformation.

    Options and Accessories

    Refer to Page 14-46.

    Layout and Sizing PRL4B Refer to Pages 14-33

    through14-35.

    PRL4F Refer to Pages 14-36through 14-38.

  • 7/13/2019 Tb 01400001 e

    29/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    14PanelboardsPow-R-Line C Panelboards

    PRL4

    Product SelectionFormula Pricing: Base Price + Branch Devices + Modifications = Total Price U.S. $

    Table 14-28. Base Prices PRL4 Main Lugs and Main Breakers

    For ground fault protection on main devices, see Modification 14 Applies to 310 and 310+ Trip Units or Modification 15, Page 14-48. 100% rated breaker. Requires copper bus. Not available in Type 12, 4 and 4X enclosures. Breaker only available in 3-pole frame. Requires 44-inch (1117.6 mm) wide box.

    Table 14-29. Base Prices PRL4 Main Fusible Switches

    For ground fault protection on main devices, see Modification 15, Page 14-48. Fuses not included. Specify required fuse clips on all switches. For T fuse clips, add $308. per switch. Class J Fuse provisions are applicable only to 600 volt units. When required, use price and dimensions of 600 volt units for all voltages 600 and below. No dc rating on 600, 800 and 1200 ampere switches.

    AmpereRating

    Interrupting Rating (kA Symmetrical) BreakerType

    Price U.S. $

    240 Vac 480 Vac 600 Vac 250 Vdc 3-Phase4-Wire

    1-Phase 3-Wire,1-Phase 2-Wire

    3-Phase3-Wire

    Main Lug Only

    250 400 600 8001200

    Main Breaker

    250 250 250 250

    65100200200

    35 65100200

    18 25 35

    102222

    JDHJDJDCLCL

    400 400 400 400 400 400 400

    400

    65 65 65100100200200

    200

    35 35 65 65100200

    200

    25 25 35 35 65

    200

    10102222

    DKKDCKD

    HKDCHKD

    KDCLCL

    LA-P 600 600 600 600 600 600 600 600

    65100 65 65100100200200

    35 65 35 35 65 65100100

    18 35 25 25 35 35 50 50

    2222222525

    LGELGHLDCLD

    HLDCHLD

    LDCCLDC

    800 800 800 800 800

    65100 65100200

    50 65 50 65200

    25 35 25 35200

    2225

    MDLHMDLCMDL

    CHMDL

    NB-P

    800 800 800 800 800 800

    65100200 65100200

    50 65100 50 65100

    25 35 65 25 35 65

    NDHNDNDCCND

    CHND

    CNDC

    120012001200120012001200

    65100200 65100200

    50 65100 50 65100

    25 35 65 25 35 65

    NDHNDNDCCND

    CHND

    CNDC

    AmpereRating

    Interrupting Rating (kA Symmetrical) Price U.S. $

    240 Vac 480 Vac Device Type 3-Phase 4-Wire 1-Phase 3-Wire, 1-Phase 2-Wire 3-Phase 3-Wire

    Main Fusible Switch 240 Vac, 250 Vdc

    200

    400 600

    800

    1200

    See Table 14-32 FDPB

    FDPWFDPWFDPWFDPW

    Main Fusible Switch 600 Vac

    200 400 600

    800

    1200

    See Table 14-32 FDPBFDPWFDPWFDPWFDPW

    Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . CE9

  • 7/13/2019 Tb 01400001 e

    30/89

    February 2007

    4-30

    For more information visit: www.eaton.com CA08101001E

    Panelboards

    4

    Pow-R-Line C Panelboards

    PRL4

    Table 14-30. Branch Devices PRL4

    Includes provisions for breaker types BAB, BAB-H, QBGF, QBHW, QBHW-H, QBHGF, GHQ, GHB, HGHB.

    50 ampere devices are available as 2-pole only. 1-pole breakers rated 120 Vac. 2-pole breakers rated 120/240 Vac. Arc fault circuit breaker. Arc fault circuit breaker with GFCI. 1-pole breakers rated 277 Vac. At 480 volts, must be used on 480Y/277 volt grounded wye systems only. AIC rating for 2- and 3-pole breakers only. 100% rated breaker. Requires copper bus. Not available in Type 12, 4 and 4X enclosures. Breaker only available in 3-pole frame. Available in single branch mounting only.

    AmpereRating

    Interrupting Rating (kA Symmetrical) BreakerType

    Price U.S. $ Price U.S. $ Space Only Price U.S. $3-PoleProvision

    240 Vac 480 Vac 600 Vac 250 Vdc 1-Pole 2-Pole 3-Pole 1-Pole 2-Pole 3-Pole

    15 60 15 60

    70 100 70 100 15 50

    15 20 15 20

    10

    10

    10

    10 10

    10

    10

    BABBAB-H

    BABBAB-HQBGFQBAF

    QBAG

    15 60 15 60 70 100 70 100 15 30 15 20 15 20

    22

    22 22

    22 22

    22

    22

    QBHWQBHW-HQBHWQBHW-HQBHGFQBHAF

    QBHAG

    15 20 15 60 70 100 15 30

    65

    65

    65

    65

    14

    14

    14

    25

    1414

    GHQ

    GHB

    GHB

    HGHB

    15 60 70 100 15 60

    70 100110 150

    18

    18

    18

    18 18

    14

    14

    14

    14 14

    14

    1414

    101010

    1010

    EHDEHDFDB

    FDBFDB

    15 60 70 100110 225 15 60 70 100110 225

    65

    65

    65

    100

    100

    100

    35

    35

    3565

    65

    65

    181818252525

    101010222222

    FDFDFDHFDHFDHFD

    15 60 70 100110 225 15 100

    200200200200

    100100100150

    353535

    222222

    FDCFDCFDCFCL

    100 225100 225100 225100 225100 225

    22 42 65100200

    EDBEDSEDEDHEDC

    70 225250 70 225250 70 225250

    65 65100100200200

    35 35 65 65100100

    181825253535

    101022222222

    JDJDHJDHJDJDCJDC

    125 250 200 200 LCL

    250 400100 400100 400100 400100 400100 400

    65 65 65100100200

    35 35 65 65100

    2525353565

    10102222

    DKKDCKD

    HKDCHKD

    KDC

    200 400 200 200 LCL

    250 600300 600300 600

    65 65 65

    35 35 35

    182525

    2222

    LGELDCLD

    Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CE9

  • 7/13/2019 Tb 01400001 e

    31/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    14PanelboardsPow-R-Line C Panelboards

    PRL4

    Table 14-30. Branch Devices PRL4 (Continued)

    100% rated breaker. Requires copper bus. Not available in Type 12, 4 and 4X enclosures. 100% rated breaker. Requires 44-inch (1117.6 mm) wide box. 100,000 AIC based on NEMA test procedure. Fuses not included. Specify required fuse clips on all switches. For T fuse clips, add $308. per switch (T fuse clips not available for

    200/200 twin switches). When branches of a twin unit are of different ampere ratings, as a 30 60 twin unit, price and layout as a 60 60 twin unit;

    when a 60 100 twin unit, price and layout as a 100 100 twin unit. No dc rating on 600, 800 and 1200 ampere switches. Twin 200 ampere switches are not available with Class R fuse clips at 600 volts.

    AmpereRating

    Interrupting Rating (kA Symmetrical) DeviceType

    Price U.S. $ Price U.S. $ Space Only Price U.S. $3-PoleProvision

    240 Vac 480 Vac 600 Vac 250 Vac 1-Pole 2-Pole 3-Pole 1-Pole 2-Pole 3-Pole

    250 600 300 600

    300 600 300 600 300 600

    100100

    100200200

    65 65

    65100100

    3535

    355050

    2225

    2525

    LGHHLD

    CHLD

    LDCCLDC

    400 800 400 800 400 800 400 800

    65100 65100

    50 65 50 65

    25352535

    2225

    MDLHMDLCMDL

    CHMDL

    400 800 400 800 400 800 400 800 400 800 400 800

    65100200 65100200

    50 65100 50 65100

    25 35 65 25 35 65

    NDHNDNDCCND

    CHND

    CNDC

    600 1200 600 1200 600 1200 600 1200 600 1200

    600 1200

    65100200 65100

    200

    50 65100 50 65

    100

    25 35 65 25 35

    65

    NDHNDNDCCND

    CHND

    CNDC

    Integrally Fused, Current Limiting Circuit Breaker

    15 100 125 225 250 400 400 600 700 800

    200200200200200

    200200200200200

    200200200200200

    FB-PLA-PLA-PNB-PNB-P

    Fusible Switches 240 Vac, 250 Vdc

    30/30

    60/60

    100/100

    200/200 100 200

    See Table 14-32 FDPW-TwinFDPW-TwinFDPW-TwinFDPB-TwinFDPW-SingleFDPB-Single

    400 600

    800

    1200

    See Table 14-32 FDPW-SingleFDPW-SingleFDPW-SingleFDPW-Single

    Fusible Switches 600 Vac

    30/30

    60/60

    100/100

    200/200

    100 200

    See Table 14-32 FDPW-TwinFDPW-TwinFDPW-TwinFDPB-TwinFDPW-SingleFDPB-Single

    400 600

    800

    1200

    See Table 14-32 FDPW-SingleFDPW-SingleFDPW-SingleFDPW-Single

    Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . CE9

  • 7/13/2019 Tb 01400001 e

    32/89

    February 2007

    4-32

    For more information visit: www.eaton.com CA08101001E

    Panelboards

    4

    Pow-R-Line C Panelboards

    PRL4

    Table 14-31. Branch Devices Earth LeakageGround Fault Circuit Breakers PRL4(Adj. Pickup from 30 mA to 30 A)

    Note: Terminals and external accessoriesare the same as standard breakers. F-Frame

    breakers are twin mounted (3X). J-Frame(3X) and K-Frame (4X) are single mountedonly. 36-inch (914.4 mm) minimum box width.

    Table 14-32. FDPW and FDPB Switch Ratings,240 or 600 Vac

    No dc rating on 600, 800 and 1200 ampereswitches.

    Class J fuse provisions are applicable to600 volt units. When required, use price anddimensions of 600 volt units for all voltages600 volts and below.

    Twin 200 ampere switches are not availablewith Class R fuse clips at 600 volts.

    When shunt trip is required, 400 600ampere switches used with Class R fusesare rated 100,000 AIC.

    AmpereRating

    kAIC (sym.) BreakerType

    Price U.S. $

    480 Vac 3-Pole

    35 60 70 100110 150

    35 35 35

    ELFDELFDELFD

    35 60 70 100110 150

    65 65 65

    ELHFDELHFDELHFD

    35 60 70 100110 150

    100100100

    ELFDCELFDCELFDC

    100 250100 250100 250

    35 65100

    ELJDELHJDELJDC

    200 400200 400200 400

    35 65100

    ELKDELHKDELKDC

    AmpereRating

    FuseClassUsed

    Short CircuitRatings(Sym. Amperes)

    30 100

    200 Single200 Twin400, 600

    800, 1200

    R, J

    R, JR, J, TR, J, TL

    200,000

    200,000200,000200,000200,000

    Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CE9

  • 7/13/2019 Tb 01400001 e

    33/89

    February 2007

    CA08101001E For more information visit: www.eaton.com

    14PanelboardsPow-R-Line C Panelboards

    PRL4

    Layout and Sizing PRL4BMain Lug (MLO), Main Breaker, Neutral, Through-Feed (TFL)and Sub-Feed Lug (