The T-Panel System 14807 Heritage Crest Way, Suite B Bluffdale, UT 84065 1-866-635-8123 www.thermal1.com • Material Recycled Aluminum Alloy 6063 Temper - T5 • Sizes. Sold in 5’ or 10’ panel extrusions. f 8” Eave T-Panel (for eaves up to 12” deep) f 12” Eave T-Panel (for eaves up to 18” deep) f 18” Eave T-Panel (for eaves up to 24” deep) f Valley T-Panel for valleys, chimneys, crickets etc f Utility T-Panel a larger version of the valley panel • Components Aluminum Alloy Snap Loc Top, Aluminum Alloy Base Panel,Aluminum Alloy Transition Panel • Colors 7 Standard Powder Coating Colors are available • Heat Source the 8” Eave, 12” Eave,Valley, Utility Panel Systems utilize 2 feet of Heat Trace per foot of panel. The 18” Eave Panel System will utilize three feet of cable per foot. Products are designed for 11mm or 14 mm commer- cial grade heat cables, mineral insulated (MI) cable or 3/8” Radiant PEX tubing *Recommended Commercial Grade- Self Regulating Heat Cable (GM-X2 12 Watt per foot in 100-130 VAC or 208-277 VAC). • Optional Items Ambient and/or Moisture Sensor Control- lers, Self regulating heat trace for gutters and downspouts • Electrical Requirements N.E.C. 426-28 requires 30 mA Ground Fault circuit protection for snow and ice melting applications Specifications Thermal Technologies T-Panel’s simple integrated drip edge and color matched cover is designed to eliminate icicles, ice dams, and snow at the roof’s edge. Thermal Technologies innovative roof snow and ice elimination systems are attractive and cost effective. They ensure that the building’s owner will not have the frustration, property damage, and costs associated with water damage, caused by the inability of the buildings’ roof to properly drain water during winter months. Thermal Technolo- gies revolutionary roof de-icing systems will extend your roof life and reduce the destructive situations that snow and ice can inflict on any roof. Mounting Eave panels are installed with sealant & roofing screws. Screws and sealant may be replaced by 3M VHB Adhesive Tape, TAM- PRO Flashing Cement or Rainbuster 14000 Silicone. The lip of the eave panel fits below the shingles, cedar shake, corrugated metal roof panels, or slate roof panels, facilitation proper mois- ture drainage off the roof structure. The T-Panel System Aluminum Extrusion Profiles (6’ lengths) 8” Eave T-Panel for eaves up to 12” deep) 12” Eave T-Panel for eaves up to 18” deep 18” Eave T-Panel for eaves up to 24” deep Valley T-Panel for Valleys Utility T-Panel for Chimneys, Valleys & Below Stairs T-Panel eave panels fit below shingles, provide a drip edge into the gutter, and eliminate ice & snow in the roof’s freeze zone.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
The T-Panel System
14807 Heritage Crest Way, Suite BBluffdale, UT 84065
SpecificationsThermal Technologies T-Panel’s simple integrated drip edge and color matched cover is designed to eliminate icicles, ice dams, and snow at the roof’s edge. Thermal Technologies innovative roof snow and ice elimination systems are attractive and cost effective. They ensure that the building’s owner will not have the frustration, property damage, and costs associated with water damage, caused by the inability of the buildings’ roof to properly drain water during winter months. Thermal Technolo-gies revolutionary roof de-icing systems will extend your roof life and reduce the destructive situations that snow and ice can inflict on any roof.
MountingEave panels are installed with sealant & roofing screws. Screws and sealant may be replaced by 3M VHB Adhesive Tape, TAM-PRO Flashing Cement or Rainbuster 14000 Silicone. The lip of the eave panel fits below the shingles, cedar shake, corrugated metal roof panels, or slate roof panels, facilitation proper mois-ture drainage off the roof structure.
The T-Panel System
Aluminum Extrusion Profiles (6’ lengths)
8” Eave T-Panel for eaves up to 12” deep)
12” Eave T-Panel for eaves up to 18” deep
18” Eave T-Panel for eaves up to 24” deep
Valley T-Panel for Valleys
Utility T-Panel for Chimneys, Valleys & Below Stairs
T-Panel eave panels fit below shingles, provide a drip edge into the gutter, and eliminate ice & snow in the roof’s freeze zone.
The T-Panel System
14807 Heritage Crest Way, Suite BBluffdale, UT 84065
1-866-635-8123www.thermal1.com
Number of feet of heat cable allowed per circuit breakerthe 8” Eave, 12” Eave, Valley, Utility Panel Systems utilize 2 feet of Heat Trace per foot of panel. The 18” Eave Panel System will utilize three feet of cable per foot. Pay strict attention to the ambient start up temperature, circuit size and load requirement.
The Eave Panel melts ice in the freeze zone at the roof’s eave.
The Valley Panel melts ice in the freeze zone at the roof’s valley.
The size of the eave freeze area determines the size of the eave panel.
Selecting a panel length
f 8”EaveT-Panel(foreavesupto12”deep)
f 12”EaveT-Panel(foreavesupto18”deep)
f 18”EaveT-Panel(foreavesupto24”deep)
12” T2 Panel
18” Deep EaveThe lower 70% length of valleys is the typical freeze zone. This area needs heat protection in cold climates.
* Only FTC-P power connection kits may be used with 40-A circuits.Bus Wires 16 AWG nickel-plated copperBraid/Outer
The T-Panel System
14807 Heritage Crest Way, Suite BBluffdale, UT 84065
1-866-635-8123www.thermal1.com
Ice Stop cables are designed to be installed within the larger of the two channels. This channel is sized for ap-proximately 14mm heat cable.
3/8 in. PEX tubing or similar sized radiant tubings are designed to be installed within the round channel. This channel is sized for approximately 3/8 inch radiant PEX tubing.
How to select the correct heat channel All of our products can incorporate different types of heat sources, such as, 14 mm self regulating heat cable, Mineral Insulated Cable and Hydronic / Radiant Tubing. Thermal Technologies’ technically advanced aluminum alloy extru-sions are manufactured with specific sized channels for specific sized heat cables.
14mmcable
3/8” pexTubing
If multiple sized channels are available, only fill one size on each side of the panel with the correct cable or tubing.
Note: All products manufactured by Thermal Technologies incorporate the same or similar superior internal configuration as the systems shown here. The same installation parameters with regards to channels vs. heat source apply to all of the other panel system products manufactured and sold by Thermal Technologies.
This picture shows the correct cable in the correct channel. The separation between the snap-loc top and base unit are designed and manufactured within tight tolerances. This separation eliminates the characteristics of a cover panel supported by the base panel, yet enables direct heat transfer or direct thermal conductivity to occur between the heat source and the base and top units. No other product designed, manufactured or sold compares to the excep-tional quality and outstanding performance of the products offered by Thermal Technologies.
The T-Panel System
14807 Heritage Crest Way, Suite BBluffdale, UT 84065
1-866-635-8123www.thermal1.com
0.73”
7.50”
2.50”
2.44”
0.73”
2.86”
Drawings
8” Eave Panel for eaves up to 12” deep
12” Eave Panel for eaves up to 18” deep
18” Eave Panel for eaves up to 24” deep
3” Valley Panel for Valleys
6” Utility Panel for valleys, chimneys, crickets etc
6.08”
0.70”
6.40”
13.00”
2.40”
0.08
”
0.38”
0.38
”
1.20
”
3.70”
0.70”
12.5”
19.34”
2.40”
0.08
”
0.38”
0.38
”
1.20
”
3.70”
The T-Panel System
14807 Heritage Crest Way, Suite BBluffdale, UT 84065
1-866-635-8123www.thermal1.com
0.73”
2.86”
3” Valley Panel for valleys, chimneys, crickets etc
Extension Joint Cap (XJ)
Leave 0.50” between panels.Cover With ExtensionJoint Cap (XJ)
5.00”0.50”
Screw HolePlacementEvery 2’ (24”)
Heat Cable
Sold in 5’ or 10’ lengths
Panel MatingPanel Mounting
The T-Panel System
14807 Heritage Crest Way, Suite BBluffdale, UT 84065
1-866-635-8123www.thermal1.com
6” Utility Panel for valleys, chimneys, crickets etc
Extension Joint Cap (XJ)
Leave 0.50” between panels.Cover With ExtensionJoint Cap (XJ)
5.00”
End Cap 5.00”
0.50”
Loop cableat end cap
6.08”
0.70”
Sold in 5’ or 10’ lengths
Screw holeplacementevery 24” on center
The T-Panel System
14807 Heritage Crest Way, Suite BBluffdale, UT 84065
1-866-635-8123www.thermal1.com
Utility Panel
Heat Cable
Roof Support
Roof Support
Roo�ng material (shingles, panels, etc)
Roo�ng material (shingles, panels, etc)
Ice and water shield
Valley Flashing
Flashing
Ice and water shield
Angle Mounting
Surface Mounting
Roo�ng Material
Manufacturer’srecommendedadhesive or cement
Non-slip powder coat
Ice-stop Heat Cable
Surface Mounting for Rubber Roof
Placement of Ice & Water Shield, Flashing and Roofing Materials
The T-Panel System
14807 Heritage Crest Way, Suite BBluffdale, UT 84065
1-866-635-8123www.thermal1.com
Power Source
Control Box
End Termination
Heat Cable
Expansion Joint Cap (XJ)
Expansion Joint Cap (XJ)
0.50” Gap Between Panels,Covered by ExpansionJoint Cap (XJ)
3.00” Gap Between Panels forCable Exit Junction,Covered by ExpansionJoint Cap (XJ)
Power Source
Control Box
To Gutters, or other panels
Example Cable Run for Utility Panels
The T-Panel System
14807 Heritage Crest Way, Suite BBluffdale, UT 84065
1-866-635-8123www.thermal1.com
Roo�ng MaterialRoo�ng Material
Ice & Water Sheild
Double Valley Panel Assembly
Roo�ng material (shingles, panels, etc)
Screw holeplacementevery 24” on center
6.00’ (72.00”)
3.00”
3.00” 12.00”
2.00”
6.00”
Double-Valley Panel
The T-Panel System
14807 Heritage Crest Way, Suite BBluffdale, UT 84065
1-866-635-8123www.thermal1.com
Flat Roof Panel
Sold in 5’ or 10’ lengths
Screw HolePlacementEvery 2’ (24”)
Heat Cable
Insert Panels to increase length
19.2”
2.297”
6.7” 5.8”
Each addition of a center panel adds 5.8”
Each addition of a center panel adds 5.8”
6.7”
0.72
6”
The T-Panel System