Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL AR24KSFPDWQXCV / AR24KSFPDWQNCV Page 1 of 3 Samsung "Quantum", wall mounted evaporator, split system QS-RAC-022017A DFWXDO HTXLSPHQW DSSHDUDQFH PD\ YDU\ www.SamsungHVAC.com General Information • Outdoor unit shall provide 208/230V power to indoor unit via 14 AWG X 3 interconnect power cable • Electro-static, washable, main filter as standard Construction • Indoor unit chassis shall be UL94 V0 with a galvanized steel mounting bracket • The outdoor unit shall be galvanized steel with a baked on powder coated finish for durability Heat Exchanger • The indoor unit heat exchanger shall be mechanically bonded fin to copper tube Refrigerant System • The compressor shall be hermetically sealed, inverter controlled, BLDC Rotary • Refrigerant flow shall be controlled by electronic expansion valve at outdoor unit Indoor Fan • The indoor fan shall be a single, antibacterial cross-flow type • Three fan speed settings and auto setting • Automatic (motorized) vertical swing louver (up/down) &RQWUROV • Control signal shall be DDC type signal • Interconnect control wiring shall be 16 AWG X 2 shielded wire between outdoor and indoor units • The indoor unit shall ship with a wireless controller and batteries as standard • Optional wired control options available Convenience • Auto restart • LED status indicator lights on front of the indoor unit to display unit operation and error status • "Fast Comfort" mode to quickly reach set temperature • Auto changeover • 24 hour, single event timer • Good'sleep mode • Quiet mode • Dry mode • Single event, ON/OFF timer • Single User Mode to reduce energy consumption during low demand operation • Air filter cleaning can be done easily without opening the indoor unit • Beep ON/OFF with included wireless controller AR24KSFPDWQ AR24KSFPDWQNCV AR24KSFPDWQXCV Nominal Capacity* Cooling / Heating (Btu/h) 22,000 / 24,000 Cooling (Btu/h) 6,100 - 27,300 Heating (Btu/h) 4,400 - 28,000 17 / 10.5 3.07 9.0 9035289 Voltage ø / V / Hz 1 / 208-230 / 60 176 - 254 Cooling (A) 2.4 / 9.8 / 13.0 Heating (A) 1.9 / 10.5 / 11.5 Max. Breaker Amps 25 19.0 Indoor Unit 41 15/16 X 11 3/4 X 9 1/16 Outdoor Unit 34 5/8 X 31 9/32 X 12 3/16 Indoor Unit 25.35 Outdoor Unit 115.74 11/16" OD Indoor Unit (dB) Quiet / High 28 / 45 Outdoor Unit (dB) High 54 14 ≤ T ≤ 115 Heating 5 ≤ T ≤ 75 Cooling 61 ≤ T ≤ 90 Heating T ≤ 80 High side (flare) 1/4" Low side (flare) 5/8" 98 / 10 49 R410A Electronic Expansion Valve Factory Charge oz. 51.2 25 feet 0.16 oz./ft. over 25 ft. BLDC Rotary RLA A 13.5 BLDC motor with cross-flow fan (1) Air Volume CFM (High) 700 Consumption Watts 25 FLA Amps 0.12 BLDC motor with axial fan (1) Output Watts 39 FLA Amps 0.17 Air Volume CFM (max.) 1,950 DB61-06087A Aspen Mini Orange ASP-MO-UNIV 110-250 Blue Diamond BD-BLUE-230 Standard AR-WRS 1 Premium (w/scheduling) AR-WRP 2 DB93-11412A DB93-11405A MIM-B14 CKN-250 25' - ILS2509 50' - ILS5009 Front WBMF-9/12/18 Back WBMB-9/12/18/36 Certifications Devices Warranty Condenser Fan AHRI Reference Number Wired controller sub-PCB harness Wired controller sub-PCB External contract control interface module (requires sub-PCB and sub-PCB harness) Optional Accessories Wireless controller holder Specifications Model System Model Number Indoor Unit Model Number Outdoor Unit Model Number Power Working Voltage Range (VAC) Operating Current (Min./Std./Max.) Performance Capacity Range SEER / EER HSPF Min. Circuit Ampacity (A) COP Sound Pressure Level Condensate Connection Dimensions W X H X D (inches) Weight (lbs.) Pipe Connections Indoor & Outdoor Maximum / Minimum Line Set Length (ft.) Maximum Vertical Separation (ft.) Operating Temperatures (ͼF) Outdoor Cooling Indoor Refrigerant Type Control Method Charged for Additional Refrigerant Compressor Type Wired controller Evaporator Fan Type Wall bracket (for outdoor unit) Motor Condensate pump Safety ETL & ETLc PCB fuses, indoor unit terminal block thermal fuse, current transformer, over-voltage protection, crankcase heating, temperature limit protection logic, compressor overload sensing 7 Years compressor, 5 years parts, 90 days limited labor (registration required) Line sets - insulated and flared, interconnect cables included Wind Baffle / Guard 1 AR-WRS includes MWR-WH00 wired controller, sub-PCB (DB93-11412A), and sub-PCB harness (DB93-11405A) 2 AR-WRP includes MWR-WE10 wired controller, sub-PCB (DB93-11412A), and sub-PCB harness (DB93-11405A) * Nominal heating capacities are based on: Indoor temperature: 70ιF DB, 60ιF WB. Outdoor temperature: 47ιF DB, 43°F WB * Nominal cooling capacities are based on: Indoor temperature: 80 ͼF DB, 67ͼF WB. Outdoor temperature: 95ͼF DB, 75°F WB • The outdoor unit heat exchanger shall be aluminum, flat fin, micro channel Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice. Refer to www.AHRIdirectory.org for current reference numbers.