This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
1/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Performance summaryBased on RO, all color temperatures,
White painted louver for NF and WW optics.
Photometric performance is measured incompliance with IESNA LM-79-08.
*Estimated. Consult website for latest ies files.
FEATURES AND BENEFITS
Physical :• Aluminum extruded housing, 2” wide• Available in 1’, 2’, 3’, 4’, 5’, 6’, 7’ or 8’ sections• Continuous runs available in 1’ increments• Durable polyester powder coat finish• Wide flood, true asymmetric wallwash or narrow flood direct lighting optics• Batwing wide or wide flood indirect lighting optics• Wallwash and narrow flood optics provided with white painted louvers • Black painted or semi-specular louver finish optional• Wide flood optic provided with frosted extruded acrylic lens • Tool-less system for reflector assembly and control gear access• Suitable for use with drywall, grid and metal pan ceilings (millwork ceilings)• Aircraft cable adjustable suspension system• Lit and unlit joiners available for custom configurations• Compatible with motion sensors• Dry location only• IK05 rated Performance :• Available in 2700K, 3000K, 3500K, 4000K or RGB color mixing for direct and indirect lighting• Binning within a 3 step MacAdam ellipse• Lumen maintenance: 100,000 hrs [L70 @ 25° C]• Lumen measurements comply with LM - 79 - 08 standard• Resolution per foot or per fixture (configured with LumenID V3 software & DMX/RDM)• Operating temperatures: -25° C to 50° C [-13F to 122F]
Electrical :• Line voltage luminaire for 100 to 347V• Standard white cable and canopy, consult factory for other options• 6W/ft Regular Output version, direct or indirect lighting• 12W/ft High Output version, direct or indirect lighting• Dimming options for white light: 0-10 volt, DMX/RDM enabled, DALI, Lumentalk or Lutron® EcoSystem® Enabled• 6W/ft optional RGB source, DMX/RDM enabled• Quick connectors for continuous runs
Client Project name
Order# Type Qty
Narrow flood(30˚ x 60˚)
Wide flood (100˚)Direct
Wide flood (100˚)Indirect
Batwing wide (170˚)
True asymmetricwallwash
CERTIFICADO No.05884,05885
RETILAP
IK05
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
2/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
ACCESSORIESOrder separately
Control Systems:LTO2 Lumentouch is a wall mount DMX 512 controller keypad.
LCU Lumencue is a USB / mini SD DMX 512 controller.
LID LumenID is a diagnostic and addressing DMX 512 controller.It must be specifi ed on all DMX applications.Refer to LID specifi cation sheet for details.
LTN Lumentone is a simple pre-programmed DMX 512 controllerwith a push button rotary dial and live feedback.
Control Boxes:CBX DMX/RDM control box.
Up to six power and data outputs to fi xtures or fi xture runs.Ethernet enabled option.Refer to CBX specifi cation sheet for details.
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
9/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Resolution per fixture: each reflector is addressed independently
BOARD AND REFLECTOR LAYOUT PER FIXTURE LENGTH
Total number of DMX addresses required
per fixture(Direct/Indirect)
Total number of DMX addresses required
per fixture(Direct/Indirect)
6 5 4
Reflector 11 2 3
Reflector 38 7 6
Reflector 39 8 7
Reflector 311 10 9 8
Reflector 312 11 10 9
8 7 6 5
Reflector 11 2 3 4
109
Reflector 2Reflector 11 2 3 45
Reflector 41210 11
Reflector 11 2 3
Reflector 246 5
Reflector 41412 13
Reflector 11 2 3 4
Reflector 257 6
Reflector 415 1613 14
Reflector 11 2 3 4
Reflector 26 58 7
IndirectDirect
IndirectDirect
IndirectDirect
IndirectDirect
IndirectDirect
IndirectDirect
IndirectDirect
RESOLUTION DETAILSApplicable for DMX/RDM control option only.Fixture resolution can be configured on-site within the LumenID V3 software. A DMX/RDM enabled CBX is required.
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
10/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Notes: 1 Maximum run length calculations are typically based on 4ft [1.2m].Each lumenline reflector requires 1x DMX/RDM or DALI address: a lumenline fixture can contain multiple reflectors,refer to Board and Reflector Layout for details. Consult factory for specific applications.
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
13/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
Notes: 1 Maximum run length calculations are typically based on 4ft [1.2m].Each lumenline reflector requires 1x DMX/RDM or DALI address: a lumenline fixture can contain multiple reflectors,refer to Board and Reflector Layout for details. Consult factory for specific applications.
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
14/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
4 Length:SU1 - Single Unit 12 1/2 inches (317mm)SU2 - Single Unit 24 1/4 inches (616mm)SU3 - Single Unit 36 1/16 inches (916mm)SU4 - Single Unit 47 7/8 inches (1216mm) SU5 - Single Unit 59 3/4 inches (1518mm)SU6 - Single Unit 71 9/16 inches (1818mm)SU7 - Single Unit 83 3/8 inches (2119mm)SU8 - Single Unit 95 1/4 inches (2419mm)C__ - Continuous run, specify in 1’ increments.
CC - Custom color and finish (please specify RAL color)11
10 Option:BLL - Black painted louver12
SSL - Semi-specular louver12
Photometric performance will vary with black and semi-specular louveroptions, see Photometric Information pages for more information.
LLI2P DI 1 2 3 4 5 6 7 8 9 10
Notes:1 347V is not available for 1' [305mm] lengths. 347V is not available for RGB color option or LT control option. 2 High output direct lighting cannot be combined with high output indirect lighting. 3 RGB optionrequires DMX/RDM control to be specified in Control section. 4 Not available for RGB color option. 5 1% minimum dimming value. Available with white light only, not available for 1' [305mm] lengths.6 10% minimum dimming value. 7 1% minimum dimming value. Fixtures set to by fixture resolution (consult the Resolution Details pages for the number of DMX addresses per fixture length and type).8 1% minimum dimming value. Available with white light only. Consult Typical Wiring Diagram pages for the number of DALI addresses per fixture length and type. 9 1% minimum dimming value. Available withwhite light only, not available for 1' [305mm] lengths. Consult Typical Wiring Diagram pages for the number of EcoSystem® addresses per fixture length and type. 10 Standard white finish for cable and canopy,consult -factory for other options. 11 North American RAL colors specified with RAL number only are provided with a smooth/high-gloss finish. Please consult factory for other RAL textures and glosses, or tomatch alternate color charts. Final color matching results may vary.12 Available for WW and NF optics, not compatible with WFL option.
EM - R23
16/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
CC - Custom color and finish (please specify RAL color)11
11 Option:BLL - Black painted louver12
SSL - Semi-specular louver12
Photometric performance will vary with black and semi-specular louveroptions, see Photometric Information pages for more information.
LLI2P DI 1 2 3 4 5 6 7 8 9 10 11
Notes:1 347V is not available for 1' [305mm] lengths. 347V is not available for RGB color option or LT control option. 2 High output direct lighting cannot be combined with high output indirect lighting. 3 RGB optionrequires DMX/RDM control to be specified in Control section. 4 Not available for RGB color option and lit joiners. 5 1% minimum dimming value. Available with white light only, not available for 1' [305mm]lengths. 6 10% minimum dimming value. 7 1% minimum dimming value. Fixtures set to by fixture resolution (consult the Resolution Details pages for the number of DMX addresses per fixture length and type).8 1% minimum dimming value. Available with white light only. Consult Typical Wiring Diagram pages for the number of DALI addresses per fixture length and type. 9 1% minimum dimming value. Available withwhite light only, not available for 1' [305mm] lengths. Consult Typical Wiring Diagram pages for the number of EcoSystem® addresses per fixture length and type. 10 Standard white finish for cable and canopy,consult factory for other options. 11 North American RAL colors specified with RAL number only are provided with a smooth/high-gloss finish. Please consult factory for other RAL textures and glosses, or tomatch alternate color charts. Final color matching results may vary. 12 Available for WW and NF optics, not compatible with WFL option.