FINAL STEP 6. CLOSE BOX STEP 5. OUTPUT TO FIXTURE STEP 1. INSTALL HOUSING STEP 2. OPEN BOX p.1/2 CBX DAISY CHAIN CONFIGURATION DMX/RDM & ETHERNET 2X CONNECTION STEPS CBX-DS ™ Bottom half of CBX housing shown 100-277V & DATA OUTPUT TO FIXTURE (TYPICAL 5 CONDUCTOR CABLE) DATA OUT - 100-277V INPUT SUITABLE STRAIN RELIEF DEVICE TO BE PROVIDED BY INSTALLING CONTRACTOR. LIVE (BLACK) NEUTRAL (WHITE) GROUND (GREEN) GROUND (GREEN) DATA INPUT DATA IN + DATA IN- DATA OUT + LIVE (BLACK) NEUTRAL (WHITE) OUT -1 DATA INPUT 100-277V & DATA OUTPUT TO FIXTURE (TYPICAL 5 CONDUCTOR CABLE) (MAXIMUM OF (4X) CASCADING CONTROL BOXES PER INSTALLATION, ISOLATED) 100-277V INPUT OPTIONAL DATA OUTPUT TO NEXT CBX (NOT ISOLATED/ NOT BOOSTED) DATA OUT - GROUND (GREEN) DATA OUT + DATA IN - DATA IN + LIVE (BLACK) NEUTRAL (WHITE) GROUND (GREEN) LIVE (BLACK) NEUTRAL (WHITE) 2X MOUNTING HOLES ON THE BOTTOM OF THE CBX 4X STEP 4. DATA INPUT (ETHERNET CONTROL OPTION) USE 1/4”-20 UNC OR M6 ANCHORING BOLTS THAT ARE APPROPRIATE FOR USE WITH YOUR MOUNTING SURFACE (PROVIDED BY INSTALLING CONTRACTOR) [160mm] 16 6 5 " 5 5 16 " [135mm] INSTALL HOUSING WITH COVER FACING UP WHEN OPEN NOTICE KEEP 5" [127mm] CLEARANCE ON ALL SIDES NOTICE USE A 5/16" [8mm] STRIP LENGTH FOR CONNECTIONS NOTICE [8mm] 16 5 " 5" [127mm] IF INPUT IS ETHERNET, CONNECT CABLE DIRECTLY TO RJ45 PORT ON CONTROL CARD AND PROCEED TO THE NEXT STEP. AS DELIVERED CAUTION WARNING ! DO NOT EXCEED CONTROL SPECIFIED VOLTAGE. WARNING ! DO NOT USE IF PARTS OR CONNECTORS ARE DAMAGED. WARNING ! CAUTION American Color Code WIRE COLOR / USE GREEN GROUND WHITE NEUTRAL BLACK LIVE 100-277V RED or PURPLE DATA + ORANGE DATA - CE Color Code WIRE COLOR / USE YELLOW/GREEN GROUND BLUE NEUTRAL BROWN LIVE 220/240V BLACK DATA + GREY DATA - American Color Code Shown CONSULT BLOCK CONNECTOR MARKINGS FOR APPROPRIATE USAGE POWER INPUT/DATA OUTPUT: RECOMMENDED WIRE GAUGE: 16 AWG [1.307mm²] RANGE: 20-12 AWG [0.519-3.301mm²] DATA INPUT: WIRE GAUGE RANGE: 24-16 AWG [0.205-1.307mm²] NOTICE WARNING ! SEPARATION OF FIELD INSTALLED POWER LIMITED CIRCUIT (DIMMING/CONTROL) WIRING FROM THE BRANCH CIRCUIT WIRING IN THE OUTLET BOX ARE TO BE MADE IN ACCORDANCE WITH LOCAL AND/OR NATIONAL ELECTRICAL INSTALLATION CODES. DISCONNECT POWER BEFORE INSTALLING OR SERVICING TO AVOID ELECTRICAL SHOCK. UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY. THE USE OF RTV SILICONE IS RECOMMENDED TO SEAL ALL ENTRY POINTS (PRESSURE GLANDS, CONDUIT). THIS WILL ENSURE THE ASSEMBLY IS WATERTIGHT. PROVIDED TOOL: FLAT SCREWDRIVER (FOR BLOCK CONNECTOR WIRING) REQUIRED TOOL: #3 PHILLIPS SCREWDRIVER DMX/Data Cable Specification DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology – USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At minimum DMX Cable shall be 1-Pair (24 AWG, 7x32 Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms Impedance, and <25 pF/ft. Capacitance. Combined Power & Data Cable Specification Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with minimum of 16 AWG annealed stranded bare copper per ASTM B-174 with a minimum temperature range of -40°C to +90°C. All conductor standing must be a minimum of 26/30 and capable of handling 13 amps. Cable must be water resistant, UL Listed and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant. STEP 3. 100-277V INPUT LOCKING CONNECTION STEP 4. DATA INPUT (DMX/RDM CONTROL OPTION) PUSH IN CONNECTION LOCKING CONNECTION SHIFT THE TERMINATION SWITCH TO THE "ON" POSITION TO TERMINATE THE LAST CBX IN THE DAISY CHAIN. FOR ALL OTHER CBX IN THE RUN SHIFT THE TERMINATION SWITCH TO THE "OFF" POSITION. NOTICE OFF ON 100-277V drawing number 121846 INSTALLATION INSTRUCTIONS 2016.07.28 NK - R5 Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289 [email protected] www.lumenpulse.com Copyright © Lumenpulse 2016 Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions. This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury. !