Top Banner
Product and Application Sourcebook AC and DC blowers performing within the air flow range of 0-1800 SCFM, pressures to10 PSIG and vacuums to14 IHG. Instrument Grade and Variable Flow Blowers Industrial Blowers Environmental Blowers Chemical Processing Blowers High Pressure Blowers Remote Drive Blowers Specialty Blowers Accessories Serving over one hundred applications and diverse industries by providing high quality industry-specific products and technical assistance. Y our Choice. Our Commitment. TM REGENERATIVE BLOWERS
16

Source Book

Apr 10, 2015

Download

Documents

api-3808778
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Source Book

Product and ApplicationSourcebookAC and DC blowers performing within the air flow range of 0-1800 SCFM, pressures to10 PSIG and vacuums to14 IHG.

• Instrument Grade and Variable Flow Blowers

• Industrial Blowers • Environmental Blowers • Chemical Processing Blowers • High Pressure Blowers • Remote Drive Blowers • Specialty Blowers • Accessories

Serving over one hundred applications and diverseindustries by providing high quality industry-specificproducts and technical assistance.

Your Choice.Our Commitment.TM

R E G E N E R A T I V E B L O W E R S

Page 2: Source Book

MULTIFLOW™ DCBLOWER SUMMARY

AIR FLOW - SCFM

INC

HE

S O

F W

AT

ER

22

20

18

16

14

12

10

8

6

4

2

PS

IG

0.75

0.50

0.25

0 10 20 30 40 50

MF573

MF501

MF571MF301

75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com

Page 2

Performance Curves for Variable Flow Blowers – Brushless DC

MINISPIRAL™BLOWER SUMMARY

AIR FLOW - SCFM

INC

HE

S O

F W

AT

ER

22

20

18

16

14

12

10

8

6

4

2

PS

IG

0.75

0.50

0.25

0 1 2 3 4 5 6 7 8 9

HDC

MDC

REVAFLOW™BLOWER SUMMARY

AIR FLOW - SCFM

INC

HE

S O

F W

AT

ER

30

25

20

15

10

5

PS

IG

1.00

0.75

0.50

0.25

0 10 20 30

R304

R2504

R205

D1508

Minispiral™ MDCSE12V21-037433 (9-15 VDC)SE24V21-037434 (24-32 VDC)

Minispiral™ HDCSE12RE21-038700 (7.5-15 VDC)SE24RE21-080257 (24-32VDC)

Revaflow™ D1506PE12N-080395 (7-12 VDC)R205PE12N-037785 (7-12 VDC)R2504 PE12N-080399 (7-12 VDC)R304PE12N-080401 (7-12 VDC)

M I N I S P I R A L ™

R E V A F L O W ™

Multiflow™DC MF301DC06-080428 (3-6 VDC)MF301DC12-080429 (7-12 VDC)MF301DC24-080430 (18-24 VDC)MF501DC12-080378 (7-12 VDC) *MF501DC24-080379 (18-24 VDC) *MF571DC24-080392 (18-24 VDC) *MF573DC24-080380 (18-24 VDC) *

M U LT I F L OW ™ D C

* Requires External Controller for operation

For other available voltage options consult your local Field Sales Engineer.

Page 3: Source Book

Performance Curves for Variable Flow Blowers – Brushless AC

MULTIFLOW™BLOWER SUMMARY

250W/120V & 400W/240V

INC

HE

S O

F W

AT

ER

80

70

60

50

40

30

20

10

PS

IG2.5

2.0

1.5

1.0

.5

AIR FLOW - SCFM

0 20 40 60 80 100 120

MF573BS

MF573ES

MF571BSMF572BH & MF572EH

MF571BH & MF571EH

MULTIFLOW™BLOWER SUMMARY

800W/120V & 1200W/240V

INC

HE

S O

F W

AT

ER

160

140

120

100

80

60

40

20

PS

IG

5.5

5.0

4.5

4.0

3.5

3.0

2.5

2.0

1.5

1.0

.5

AIR FLOW - SCFM

0 30 60 90 120 150 180

MF573KS

MF573HS

MF572HH

MF571HH

MF572KH

MF571KH

Multiflow™ 250 Watt – 120 Volt Models

MF571BS2M-080343*MF571BH2M-080345*MF572BH2M-080347*MF573BS2M-080351*

Multiflow™ 400 Watt – 240 Volt Models

MF571EH3M-080355*MF572EH3M-080357*MF573ES3M-080363*

Multiflow™ 800 Watt – 120 Volt Models

MF571HH2M-080365*MF572HH2M-080367*MF573HS2M-080369*

Multiflow™ 1200 Watt – 240 Volt Models

MF571KH3M-080371*MF572KH3M-080373*MF573KS3M-080376*

M U L T I F L O W ™

75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com

Page 3* Mechanical speed adjustment models shown. All models available with electronic speed control option.

Page 4: Source Book

Performance Curves for Regenerative Blowers Below 4.0 PSIG – 0 to 230 SCFM

FLOW RATE – SCFM

INCH

ES O

F W

ATER

PSIG

140

130

120

110

100

90

80

70

60

50

40

30

20

10

5.0

4.5

4.0

3.5

3.0

2.5

2.0

1.5

1.0

0.5

10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 2500

0 1 2 3 4

4

3

2

1

SCFM

INCH

ES O

F W

ATER

A

N

O

P

E DH

C

K

G

F

IJ

B

L

M

Q

PRESSURE CURVES(Shown for 60 Hz; 50 Hz data

available on request.)

A SE 2B (AC)B SL 2C SL 4D SL 5

E DR 068F DR 083G DR 101

H DR 202I DR 303J DR 353

K DR 404L DR 513M DR 454

N DR 505O DR 555P DR 606Q DR 6

75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com

Page 4

Page 5: Source Book

75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com

Page 5

Performance Curves for Regenerative Blowers Below 7.0 IHg – 0 to 230 SCFM

FLOW RATE – SCFM

INCH

ES O

F W

ATER

INCH

ES O

F M

ERCU

RY

10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250

-120

-110

-100

-90

-80

-70

-60

-50

-40

-30

-20

-10

9

8

7

6

5

4

3

2

1

0 1 2 3 4

4

3

2

1

SCFM

INCH

ES O

F W

ATER

0

E

D

H

C

K

G

F

I

A

J

B

L

M

N

O

P

Q

SUCTION CURVES(Shown for 60 Hz; 50 Hz data

available on request.)

A SE 2B (AC)B SL 2C SL 4D SL 5

E DR 068F DR 083G DR 101

H DR 202I DR 303J DR 353

K DR 404L DR 513M DR 454

N DR 505O DR 555P DR 606Q DR 6

Page 6: Source Book

Performance Curves for Regenerative Blowers Below 5.0 PSIG – 100 to 1800 SCFM

FLOW RATE – SCFM

INCH

ES O

F W

ATER

PSIG

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700

BB

CC

140

130

120

110

100

90

80

70

60

50

40

30

20

10

5.0

4.5

4.0

3.5

3.0

2.5

2.0

1.5

1.0

0.5 AA

DD

EE

GG

FF

HH

PRESSURE CURVES(Shown for 60 Hz; 50 Hz data

available on request.)

AA DR 707BB DR 808

CC DR 858DD DR P9

EE DR 909FF DR P13

GG DR 14HH DR P15

75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com

Page 6

Page 7: Source Book

75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com

Page 7

Performance Curves for Regenerative Blowers Below 8.0 IHg – 50 to 1800 SCFM

AA DR 707BB DR 808

CC DR 858DD DR P9

EE DR 909FF DR P13

GG DR 14HH DR P15

FLOW RATE – SCFM

INCH

ES O

F W

ATER

INCH

ES O

F M

ERCU

RY

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700

-120

-110

-100

-90

-80

-70

-60

-50

-40

-30

-20

-10

9

8

7

6

5

4

3

2

1

AA

BB

CC

DD

EE

GG

FF

HH

SUCTION CURVES(Shown for 60 Hz; 50 Hz data

available on request.)

Page 8: Source Book

Performance Curves for Regenerative Blowers Above 5.0 PSIG – 50 to 900 SCFM

FLOW RATE – SCFM

INCH

ES O

F W

ATER

PSIG

PRESSURE CURVES(Shown for 60 Hz; 50 Hz data

available on request.)

280

260

240

220

200

180

160

140

120

100

80

60

40

20

10

9

8

7

6

5

4

3

2

1

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850

HPB

HPA

HPD

HPC

HPE

HPG

HPF

HPH

HPK

HPI

HPJ

HPA DR 523HPB DR S543HPC DR 623

HPD DR S7HPE DR 823HPF DR S75

HPG DR S85HPH DR S9HPI DR 1223

HPJ DR S13HPK DR S15

75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com

Page 8

Page 9: Source Book

75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com

Page 9

Performance Curves for Regenerative Blowers Above 8.0 IHg – 0 to 900 SCFM

FLOW RATE – SCFM

-180

-160

-140

-120

-100

-80

-60

-40

-20

14

12

10

8

6

4

2

INCH

ES O

F W

ATER

INCH

ES O

F M

ERCU

RY

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850

HSA

HSB

HSD

HSC

HSE

HSG

HSF

HSH

HSK

HSI

HSJ

SUCTION CURVES(Shown for 60 Hz; 50 Hz data

available on request.)

HSA DR 523HSB DR S543HSC DR 623

HSD DR S7HSE DR 823HSF DR S75

HSG DR S85HSH DR S9HSPI DR 1223

HSJ DR S13HSK DR S15

Page 10: Source Book

75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com

Page 10

CCoonnssuulltt yyoouurr llooccaall FFiieelldd SSaalleess EEnnggiinneeeerr ttoo rreeqquueesstt oouurr ccoommpplleettee ccaattaalloogg ffoorr iinndduussttrriiaall pprroodduucctt ssppeecciiffiiccaattiioonnss aanndd aapppplliiccaattiioonnss..

Photo Weight X Length Y Width Z Height Inlet/OutletBlowers 3 Index (lbs.) (Inches) (Inches) (Inches) Connections 1

MINISPIRALTM

SE 2B (AC) A 1 1.7 4.1 4.2SE 12V, 24V A 1 1.7 4.1 4.2 0.75"OD-S.O.SE 12RE B 1 2.7 4.1 4.2

NAUTILAIR TM

NC 33 C 13 11.5 7.0 10.9 5.0"OD-S.O.

SPIRALTM

SL 2 D 27 7.9 10.0 10.0 1.75"OD-S.O.SL 4,5 E 43 9.3 10.0 10.0

REVAFLOWTM

D 1506 F 0.6 2.8 3.0 2.9 1.03"x1.05"-S.O.R 205 G 0.6 3.4 2.8 2.9 0.812"OD-S.O.R 2504 G 0.6 4.4 2.7 3.3 0.812"OD-S.O.R 304 H 0.8 4.0 2.8 4.5 1.71"x0.68"-S.O.

MULTIFLOWTM

MF301 I 1.0 2.9 2.5 2.7 0.81"OD-S.O.MF501 I 1.1 5.0 3.0 5.0 0.88"OD-S.O.MF571 J 4 5.9 6.7 6.1 1.25"OD-S.O. 2

MF572 J 5 5.9 6.7 7.1 1.25"OD-S.O. 2

MF573 J 6 5.9 6.7 7.8 1.25"OD-S.O. 2

Full Product Dimensional Listing

B C D

JG H

XY

Z

Y X

Z

XY

Z

Y

Z

X

E

Y

Z

XY

Z

X Y

Z

Y

Z

X

F I

Z

X

A

Z

X

Y

Y

X

1 SO-Slip On 2 1.75"OD-S.O. for high flow models 3 Remote drive available on Multiflow model

Page 11: Source Book

Photo Weight X Length Y Width Z Height Inlet/OutletBlowers 3 Index (lbs.) (Inches) (Inches) (Inches) Connections 1

DRXOXDR 068 K 8 6.0 6.3 6.7 1.0"OD-S.O.DR 083 K 12 6.7 7.3 7.8 1.0"OD-S.O.

DR/EN/CPXOXDR/EN/CP 101 K 26 11.2 7.2 8.2 1"NPSC-FDR/EN/CP 202 K 29 11.4 8.9 9.5 1"NPSC-FDR/EN/CP 303 K 36 12.6 9.6 10.2 11/4"NPSC-FDR/EN/CP 353 K 56 11.9 11.0 11.5 11/4"NPSC-FDR/EN/CP 404 K 61 14.4 11.6 12.2 11/2"NPSC-FDR/EN/CP 454 K 73 14.6 12.6 13.5 11/2"NPSC-FDR/EN/CP 513 K 87 12.8 12.8 15.9 11/2"NPSC-FDR/EN/CP 505 K 82 14.7 13.5 14.5 11/2"NPSC-FDR/EN/CP 555 K 95 17.1 14.4 15.1 11/2"NPSC-FDR/EN/CP 606 K 108 17.0 14.8 15.6 2"NPSC-FDR/EN/CP 6 L 133 18.1 16.4 16.7 2"NPSC-FDR/EN/CP 707 K/ M 156 18.2 16.3 16.7 21/2"NPSC-FDR/EN/CP 808 K/ M 201 23.1 18.8 21.1 21/2"NPSC-FDR/EN/CP 858 M / K 258 24.0 18.6 21.8 21/2"NPSC-FDR/EN/CP 909 M / K 426 24.3 19.6 23.0 4"NPSC-FDR/EN/CP 14 M 767 30.0 23.4 27.0 4"NPSC-F

DR/EN/CP High PressureDR/EN/CP 523 K 118 18.5 14.2 15.9 11/2"NPSC-FDR S543 N 172 26.0 12.8 17.4 2"NPSC-FDR/EN/CP 623 K 180 22.0 16.5 17.5 2"NPSC-FDR S7 N 185 23.1 16.4 17.4 2"NPT-FDR/EN/CP 823 K 300 21.8 20.5 21.8 3"NPSC-FDR S75 N 230 23.3 16.3 17.0 2"NPSC-FDR S85 N 280 30.7 18.7 20.5 21/2"NPSC-F 2

DR S9/P9 N 420 31.5 18.0 21.0 21/2"NPT-FDR/EN/CP 1223 K 400 28.1 20.5 22.1 4"NPSC-FDR S13/P13 N 687 36.0 19.6 23.3 3"NPT-F 2

DR S15/P15 N 1025 39.0 23.4 28.0 4"NPT-F 2

75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com

Page 11

Full Product Dimensional Listing

K L

Y

Z

X Y

Z

X

M

Y

Z

X Y

Z

X

N

3 Remote drives available on DR/EN/CPXOX Models. Contact factory for other dimensions and sizes.

2 DR P9 has 4"OD-SO outletDR P13 has 4"NPSC-F outletDR P15 has 6"NPSC-F outlet

1 SO-Slip OnF-Female ThreadM-Male ThreadNPSC-National Pipe Straight CourseNPT-National Pipe Taper

Base Mount Rail Mount Rail Mount Duplex Rail Mount

Page 12: Source Book

75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com

Page 12

Blower Accessories

Filtration AccessoriesInlet and Inline Filters• Inlet filters protect the blower and the air distribution system from dust, and other

airborne particles and contaminants. Normally used in pressure systems. Inline filters protect the blower from harmful dust and other particles that may be drawn into theblower through the air distribution system. (8 -10 micron standard – others available)

Filter Silencers and Elements• Inlet filter/silencers reduce noise levels while ensuring clean air is provided to the blower

and the air distribution system. Normally used in pressure applications. All Rotron air filters and filter/silencers have replaceable filter elements. The filter media is polyesterdesigned for high efficiency over a wide spectrum of industrial applications.

Moisture Separator™• By separating and containing entrained liquids, Rotron’s moisture separator helps protect

our regenerative blowers and the end treatment system from corrosion and mineralizationdamage. Recommended for all soil vacuum extraction applications.

Measurement AccessoriesAir Flow Meter (Analog, 4-20 mA, Digital Readout)• Measures air flow rates to aid in the balance of multi-pipe systems, detect channeling

or plugging of a line and allow system fine tuning for optimal performance. An optional4-20 mA output can be used to achieve systems with fully automated flow control. Digital readouts in SCFM also available.

Gauges and Relief Valves• Rotron has a variety of gauges for pressure, vacuum and temperature measurements

in various ranges. These gauges are reliable and rugged. The relief valve is installed to prevent excessive system pressure or vacuum that could result from line restrictions.

Noise Reduction AccessoriesInlet and Inline Mufflers• Inlet/outlet mufflers lower blower noise in areas where reduced sound levels are required.

Inline mufflers are utilized for noise reduction in applications where piping systems are connected directly to both ends of the muffler.

Protection AccessoriesAir Flow Switch• Rotron’s air flow switch sends a control signal in response to increasing or decreasing

velocity of the air stream. Useful in automatically initiating process controls, wanning systems on as an interlock for on-off purposes.

Explosion-Proof Motor Starter• The National Electric Code requires the use of starters with explosion-proof motors

equipped with pilot duty thermal overload protection. These UL & CSA approved explosion-proof starters protect the blowers from electrical malfunctions.

Pressure/Vacuum/Temperature Switches• Our adjustable switches can automatically initiate equipment shutdown, alarm systems

or interlocking machine functions to insure that blower output parameters stay withinprocess specifications.

System AccessoriesAir Knives• The Rotron air knife is located at a strategic point in your assembly line conveyor belt area.

Air flows from the blower outlet through a pipe and into the air knife plenum, where asheet of air is directed out through a proprietary linear nozzle design onto assembly lineparts. This system can be used for cleaning parts, drying, or blowing back particles and liquids.

Diverter Valves• These unique solenoid actuated diverter valves automatically change air piping from

pressure to suction; greatly enhancing blower versatility and productivity. This valve iseffective in blower applications that require frequent switching of air from pressure to suction and vice-versa.

Eductors• Eductors expand blower versatility and can be used effectively in conjunction with

Rotron regenerative blowers to boost air or gas to create material handling systems inwhich the conveyed material does not pass through the blower, and to create low or noflow suctions exceeding the suction from a blower alone.

Air Flow Meter

Filter

ReliefValve

Explosion-ProofMotor Starter

Gauge

Moisture Separator TM

Air Knife

Air Flow Switch

Diverter Valve

Muffler

Page 13: Source Book

Application 1: Air-Assisted Breathing

MMaannuuffaaccttuurriinngg PARP Respiration

MMiinniinnggPARP Respiration

Your own imagination and knowledge are probably the best source of in-plant and on-site applications for Rotron regenerative blowers. The remaining sections of this guide will help to pinpoint and stimulate your consideration of themany alternative sources we provide to replace costly and maintenance intensive suction and pressure units and systems.

The nine major application groups are listed and a cross reference of most common applications by industry will helpyou identify both identical and similar applications in your industrial operations.

Application 2: Air-Assisted Inflation or Support

MMaatteerriiaall HHaannddlliinnggAir SlidesAir TablesCarbon Black Car Unloading

PPaappeerr PPrroocceessssiinnggFlotation TablesForming BarSheet FlutteringTurn Bars

TTeexxttiilleeGarment Flotation Tables

WWaatteerr PPoolllluuttiioonn CCoonnttrroollPollution ContainmentWaterway Management

Nine Major Blower Application Areas

Application 3: Air-Assisted Vacuum Pick-Up or Hold-Down

MMaannuuffaaccttuurriinnggBag Filling EquipmentCutting TablesPackaging EquipmentVacuum Manipulators

PPaappeerr oorr PPllaassttiiccss HHaannddlliinnggCutting TablesDiaper Making EquipmentPrinting Presses

TTeexxttiilleeGarment Cutting TablesYarn Guiding and TensioningYarn AspirationYarn Stringup

FLOTATION TABLES

TURNING & FORMING BARSAIR SLIDES/AIR TABLES

GENERAL PART PICK-UP GENERAL PART HOLD-DOWN

NOSE MOUTH THROAT

VACUUM MANIPULATOR CUTTING & PRINTING HOLD-DOWN TABLE

75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com

Page 13

BLOWER

BLOWER

BLOWER

BLOWER

BLOWER

BLOWER

Page 14: Source Book

75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com

Page 14

Application 6: Gas, Vapor & Fume Recovery, Venting & Treatment

AAggrriiccuullttuurraallMethane Gas Recovery

CChheemmiiccaall PPrroocceessssiinnggVent Header Off-Gassing

EEnnvviirroonnmmeennttaallGasoline Vapor RecoveryLagoon Gas RecoveryLandfill Gas RecoveryRadon Gas CollectionSoil Vapor Extraction

FFoouunnddrryyLost Foam Off-Gassing

MMaannuuffaaccttuurriinngg -- PPllaanntt SSeerrvviicceessCabinet Fume VentingEnvironmental Test Chamber VentingLaser Smoke RemovalWeld Smoke Removal

Application 5: Electronic Cooling

IInnssttrruummeennttaattiioonnEngine/Motor CoolingFilm Development System CoolingLamp Bank CoolingSmall Enclosure Cooling

Nine Major Blower Application Areas

Application 4: Air & Gas Sampling, Boosting or Circulating

AAiirr PPoolllluuttiioonn CCoonnttrroollAir SamplingAir Stream Release MonitoringFire Prevention Air SamplingFlue Gas Sampling

FFoouunnddrryyCombustion Air Boost

IInnssttrruummeennttaattiioonnGlove Box PressurizingIncubator Air CirculationWeather Measurement Sampling

MMaannuuffaaccttuurriinnggCombustion Air BoostNatural Gas BoostOil Demisting

PPhhaarrmmaacceeuuttiiccaallClean Room Air CirculationOxygen Generator

PPllaassttiiccss HHaannddlliinnggDesiccant Dryer Bed Regeneration

FLUID BED REGENERATION TRANSMISSOMETER LENS PURGING

COMBUSTION AIR BOOST

NATURAL GAS BOOST AIR & GAS SAMPLING

PRESSURIZED CABINET VACUUM PULL-THROUGH CABINET

SOIL VAPOR EXTRACTION & LANDFILL GAS RECOVERY VENT HEADER OFF-GASSING

FUME & SMOKE REMOVAL DIGESTER GAS COLLECTION

PPhhaarrmmaacceeuuttiiccaallSterilization Gas (ETO)

Recovery

RReeffiinneerriieessCentrifuge Venting

WWaatteerr PPoolllluuttiioonn CCoonnttrroollDigester Gas Collection

BLOWERBLOWER

BLOWER

BLOWER BLOWER

BLOWER

BLOWER

BLOWERBLOWER

BLOWER

BLOWER

Page 15: Source Book

Application 8: Parts Blow-Off & Drying

AAqquueeoouuss PPrreecciissiioonn CClleeaanniinnggAutomotive Parts DryingSemiconductor Board Drying

FFoooodd PPrroocceessssiinnggBatter Blow-OffBottle & Can DryingLabel DryingSalt, Spice & Flour Blow-Off

Application 9: Solution & Media Agitation & Aeration

AAqquuaaccuullttuurreeAquarium, Fish Farm, Hatchery & Pond Aeration

EEnnvviirroonnmmeennttaallGroundwater Sparging

MMaannuuffaaccttuurriinnggConcrete Fluid Bed AerationElectroplating Tank Agitation

MMaatteerriiaall HHaannddlliinnggFluidized Beds

RReeccrreeaattiioonnCommercial Spa Aeration

WWaatteerr MMaannaaggeemmeennttBoat, Dock & Dam Face Deicing

WWaatteerr PPoolllluuttiioonn CCoonnttrroollUV Tube AgitationWastewater Filter BackwashWastewater Treatment Tank Aeration

Nine Major Blower Application Areas

MMaannuuffaaccttuurriinnggConveyor Belt Blow-OffElectroplating Fume GuidingElectroplating Part DryingElectroplating Solution

Blow-BackFlat or Irregular Metal Port

DryingWire Drying

Application 7: Solid Material Transporting, Separation &Collection

FFoouunnddrryySand Reclamation

MMaannuuffaaccttuurriinngg --WWaassttee CCoonnttrroollChip, Dust & Particle RemovalLiquid & Solvent RemovalPaper, Plastic, Film & Textile (Trim) Removal

MMaatteerriiaall HHaannddlliinnggAir SlidesBlast CleaningDilute Phase ConveyingPneumatic Tube

PPaacckkaaggiinnggBag Filling

DILUTE PHASE PNEUMATIC CONVEYING PNEUMATIC TUBE

PAPER, PLASTIC, FILM & TEXTILE(TRIM) REMOVAL

GENERAL MATERIAL SEPARATION& COLLECTION

GENERAL PARTS BLOW-OFF & DRYING SOLUTION BLOW-BACK

WASTEWATER TREATMENT TANK AERATION GROUNDWATER SPARGING

ELECTROPLATING TANK AERATION COMMERCIAL SPA AERATION

BIN PAD & FLUIDIZED BED AERATION BOAT & DOCK DEICING

75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com

Page 15

PRESSUREBLOWER

BLOWER

BLOWERBLOWER

BLOWERBLOWER

BLOWER

BLOWER

BLOWER

BLOWERBLOWER

BLOWER

Page 16: Source Book

R E G E N E R A T I V E B L O W E R S

YourChoice.OurCommitment.™For further application assistance, or to request AMETEK Rotron’s Complete Product Catalog, please contact the above listed Field

Sales Engineer for your area. For assistance outside of North America contact the factory for more information.

75 North St., Saugerties, NY 12477 • e mail: [email protected] • internet: www.rotrontmd.com • Phone: (914) 246-3401 • FAX: (914) 246-3802Copyright © 1998 10M 11/98

http://www.ametektmd.com/fieldsales.htm

For Up to Date Rep Listing, Please Visit:

Factory Representation – North America