1 Residential Products and Applications Featuring Vent Lights and Premium Grilles The World’s Leading Producer of Air Movement Products AP_1211 December 2011 • Bathroom Exhaust • Range Hood Exhaust • Clothes Dryer Boosting • Garage Ventilation • Indoor Air Quality (IAQ)
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
1
Residential Products and Applications
Featuring Vent Lights and Premium Grilles
The World’s Leading Producer of Air Movement Products
AP_1211December 2011
• Bathroom Exhaust• Range Hood Exhaust• Clothes Dryer Boosting• Garage Ventilation• Indoor Air Quality (IAQ)
2
SOLVED!S&P, the world’s leading producer of air movement products, offers a full selection of fan solutions for all of your residential ventilation requirements. Inline remote fans are the most effective way to vent today’s homes and do so with less noise, better air flow and are both affordable and aesthetically appealing (the fan is hidden). In addition, S&P offers more solutions with multiple fan choices to meet all your requirements. Whatever your requirements... S&P has a solution.
Look for our “Fans for Life” symbolWe certify the fans that bear this symbol offer the lowest possible energy use and running costs, while still providing the highest possible performance.
3
Model
Mounting Locations
Impeller Type Certifications
CFM Range (at 0” SP)
S&P
fan
Rec
omm
enda
tions
App
licat
ions
Inlin
e/D
uct
Cei
ling
Side
wal
l
Mix
ed F
low
Cen
trifu
gal
ENER
GY
STA
R
UL
HVI
TD-MIXVENT
x x x x x 91-1050
Economical Concerns and Most
Applications
BathroomRange Hood
Garage
TD-SILENT
x x x x x 108-530Extreme
Noise Concerns
BathroomRange Hood
Garage
PV-POWERVENT
x x x x x 108-942
ExtremeHigh Static Pressure Concerns
BathroomRange Hood
Clothes DryerGarage
SWF-SIDEWALL
x x x x 108-491Limited
Access to duct
BathroomClothes Dryer
Garage
V-SERIES
x x x x x 31-150Traditional bathroom
needsBathroom
TR-SERIES
x x x x x 46-310 IAQ Concerns
Bathroom*IAQ
Fan Options GuideThis Ventilation Options Guide is designed to help you choose with S&P fan is perfect for your requirements.
*See IAQ Applications (page 40) for information on using the TR-Series for Bathroom Exhaust
4
Technical SpecificationsWarrantyFive (5) year limited warranty.
RangeAll twelve (12) PV model sizes (PV 100, 100x, 125, 125x, 150, 150x, 200, 200x, 250, 250x, 315 and 315x) include the following specifications:
Casing• Manufactured from high grade pressed galvanized steel, with black baked enamel coating.• Extra long inlet and discharge collars make installation quick and trouble free.• Supplied with a strong galvanized steel mounting bracket.• Supplied with a prewired junction box.
Wheel / Impeller• Backward curved centrifugal type constructed of metal.• Factory matched to an external rotor motor and dynamically balanced to eliminate vibration.
Accessories• A wide range of accessories is available to complete the most demanding installation.
Motor• Totally enclosed permanent split capacitor start and run external rotor motors.• 115V 60Hz (single phase) electrical connection.• Permanently sealed, self lubricating precision ball bearings.• Safety Thermal Overload Protection Cut-Out (Automatic Reset Type).• All Models are suitable for working airstreams up to 140° F
Code Approval• All models have been independently safety tested by Underwriters Laboratories, Inc. and are UL and cUL Listed.• Independently safety tested by Intertek Laboratories, and are ETL Listed.• Independently tested for Airflow Performance. The PV range is licensed to bear the AMCA seal for Air Performance.• The PV product range is certified by the Home Ventilating Institute (HVI) for Air Performance.• PV-150x and larger are ENERGY STAR® qualified.• All models are NAHB - National Green Building Green Approved.
PV-POWERVENT SERIES
5
SoundFan sound levels are measured in sones. At this time there are no sone level test standards available through HVI due to the fact that remote mounted fan noise levels are in proportion to the following: type of duct, length of duct, fan dis-tance from the intake source and other miscellaneous factors. However, it is generally accepted that remote mounted venting is usually quieter than standard (in room) venting.
Dimensional DataDimensions (inches/mm)
Soler & Palau USA certifies that the PV range shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and proce-dures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
Performance certified is for installation type D-Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Speed (RPM or RPS) shown is nominal. Performance is based on actual speed of test.
Air Performance Technical Data
The PV-POWERVENT Series fans are California Title 24 compliant and meet ASHRAE 62.2 when installed with 3 way switch and remotely mounted speed control.
PV-POWERVENT SERIES
Model A B C D E F G Weightlbs(kgs)
PV-100 313/16
97.5313/16
97.543/4
120711/16
19671/2
19043/4
12099/16
2437
3.0
PV-100x 313/16
97.5313/16
97.543/4
120711/16
19671/2
19043/4
12099/16
2437
3.0
PV-125 413/16
122.5413/16
122.543/4
120713/16
19871/2
19043/4
12099/16
2437
3.0
PV-125x 413/16
122.5413/16
122.543/4
120713/16
19871/2
19043/4
12099/16
2437
3.0
PV-150 513/16
147513/16
14743/4
12087/16
21495/16
23643/4
120131/8
33411
5.0
PV-150x 513/16
147513/16
14743/4
12087/16
21495/16
23643/4
120131/8
33411
5.0
PV-200 713/16
198713/16
19843/4
12083/4
22395/16
23643/4
120131/8
33411
5.0
PV-200x 713/16
198713/16
19843/4
12083/4
22395/16
23643/4
120131/8
33411
5.0
PV-250 93/4
24893/4
24843/4
12081/16
20595/16
23643/4
120131/8
33413
6.0
PV-250x 93/4
24893/4
24843/4
12081/16
20595/16
23643/4
120131/8
33413
6.0
PV-315 125/16
312125/16
31243/4
12093/16
233109/16
26943/4
1201513/16
40121
10.0
PV-315x 125/16
312125/16
31243/4
12093/16
233109/16
26943/4
1201513/16
40121
10.0
A
C
D
E
F
B
G
6
Technical SpecificationsWarrantyFive (5) year limited warranty.
RangeAll five SWF models sizes (SWF 100, 100x, 150, 150x & 200) include the following specifications:
Casing• Manufactured from high grade pressed galvanized steel, with baked enamel coating.• Removable top for easy access to motor for cleaning or inspection.• Large grille opening for easy passing of lint and other potentially clogging materials.• Includes prewired terminal box.
Wheel/Impeller• Backward curved centrifugal type.• Factory matched to an external rotor motor and dynamically balanced to eliminate vibration.
Accessories• A wide range of accessories is available to complete the most demanding installation.
Motors• Totally enclosed permanent split capacity start and run external rotor motors.• 115V 60Hz (single phase) electrical connection.• Permanently sealed, self lubricating precision ball bearings.• Safety Thermal Overload Protection Cut-Out (Automatic Reset Type).• All models are suitable for working airstreams up to 140ºF.
Code Approval• All models have been independently safety tested by Underwriters Laboratories, Inc. and are UL and cUL listed.• The SWF product range is certified by the Home Ventilating Institute (HVI) for Air Performance.• All models are NAHB - National Green Building Green Approved.
SoundFan sound levels are measured in sones. At this time there are no sone level test standards available through HVI due to the fact that remote mounted fan noise levels are in proportion to the following: type of duct, length of duct, fan distance from the intake source and other miscellaneous factors. However, it is generally accepted that remote mounted venting is usually quieter than standard (in room) venting.
The SWF-SIDEWALL Series fans are California Title 24 compliant and meet ASHRAE 62.2 when installed with 3 way switch and remotely mounted speed control.
Low profile mixed flow fans, manufactured in plastic material (up to model 200) or in galvanized steel sheet protected with Epoxy paint (model 250 and 315), with external terminal box, removable motor-impeller assembly and adjustable single-phase motor, Class B, IP44.
The extensive range of the TD-MIXVENT series makes it an effective solution for a wide range of residential and light commercial ventilation installations.
100 100x 125 150 200 250 315Polypropylene housing • • • • •Steel housing with epoxy coating • •ABS fan blades • • • • •Aluminum fan blades • •Thermal link via fuse •Thermal link with automatic reset • • • • • •Permanently lubricated ball bearings • • • • • • •Speed controllable 2-speed motor • • • • • • •
Construction characteristics
General Details of the TD-MIXVENT RangeGeneral Details of the TD-MIXVENT Range
9
Easy Maintenance
Low Profile
The low profile of the fans in the TD-MIXVENT range makes them the ideal product for installations with low height limits, such as the case of suspended ceilings.
Flexibility in Location
The fans can be connected at any point along the ventilation duct: along the duct or at the end.
Removable body, for repair or cleaning,without the need to touch the ducts.
Easy to Install
Secure the support. Make the connections. Connect the ducts.
Option 1
Option 2
TD-MIXVENT Installation & Maintenance
1 2 3
10
Technical Specifications WarrantyFive (5) year limited warranty.
RangeThe TD-MIXVENT series consists of seven (7) nominal sized in-line fans. All models are specifically designed for direct connection in-line with industry standard diameter round ducting.
ConstructionThe TD-MIXVENT models 100, 100x, 125,150, and 200 are manufactured in tough reinforced plastic, models 250 and 315 have a metal casing and are finished in a tough epoxy-polyester paint coating. The TD fan duct connection flanges are manufactured from reinforced plastic, except for models 200, 250 and 315 which are constructed from epoxy-polyester coated metal.
ImpellersThe impeller blades for models 100, 100x, 125, 150 and 200 are molded in tough ABS plastic. Models 250 and 315 are metal.
MotorsModels 100, 100x and 125 :Single-phase, 120V 60Hz, shaded pole induction asynchronous motor in die cast aluminum. All motors include direct two speed connection and are also suitable for voltage speed control. • Class ll electrical insulation (model 100) & Class l (models 100x and 125)• IP 44 Protection• Class B Motor Insulation• Safety auto reset Thermal Overload Protection (fuse type)• Self-lubricating sleeve bearings.• Suitable for working airstreams up to 104° F (40°C).
Models 150, 200, 250 and 315:• Single-phase induction asynchronous motor, with permanent capacitor and external rotor constructed of die cast aluminum. Models 150, 200 and 315 include direct two speed connection and are also suitable for voltage speed control.• Class I electrical insulation • IP 44 Protection• Thermal Overload Protection • Class B Motor Insulation• Sealed For Life, ball bearings• Suitable for working airstreams up to 140° F (60°C).
Code Approval• All models have been independently safety tested by Underwriters Laboratories, Inc. and are UL and cUL Listed.• Independently tested for Airflow Performance. The PV range is licensed to bear the AMCA seal for Air Performance.• The TD product range is certified by the Home Ventilating Institute (HVI) for Air Performance.• All models are ENERGY STAR® qualified.• All models are NAHB - National Green Building Green Approved.
TD-MIXVENT SERIES
11
Dimensional DataDimensions (inches/mm) Model X A B C D E F G H
TD-100 5 15/16
1519 1/8
2325 7/16
1383 3/4
963 7/8
983 1/4
823 3/4
9517/8
482 1/16
52
TD-100x 7 3/8
18811 15/16
3036 15/16
1764 1/2
1153 13/16
973 15/16
1003 9/16
903 1/8
802 3/8
60
TD-125 7 3/8
18810 3/16
2586 15/16
1764 1/2
1154 13/16
1233 15/16
1003 9/16
903 1/8
802 3/8
60
TD-150 8 3/8
21211 5/8
2957 7/8
2005
1275 13/16
1474 7/16
1125 1/8
1303 1/8
802 3/8
60
TD-200 9 3/16
23311 7/8
3028 9/16
2175 9/16
1417 13/16
1984 7/8
1245 1/2
1403 15/16
1003 11/16
94
TD-250 11 7/16
29115 3/16
38610 11/16
2727 9/16
1929 3/4
2486 1/8
1556 5/8
1685 11/16
1455 1/2
140
TD-315 14356
17 11/16
45013 1/4
3368 13/16
22412 5/16
3127 3/8
1888 1/4
2107 3/16
1827
178
Soler & Palau USA certifies that the TD range shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Pub-lication 211 and comply with the requirements of the AMCA Certi-fied Ratings Program.
LS= Low Speed
HS=High Speed
Performance certified is for installation type D-Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Speed (RPM or RPS) shown is nominal. Performance is based on actual speed of test.
Air Performance Technical Data
Model Nom.RPM Volts Max.
Watts SpeedCFM v Static Pressure (SP) Ins. WG Max.
The TD-MIXVENT Series fans are California Title 24 compliant and meet ASHRAE 62.2 when installed with 3 way switch and remotely mounted speed control.
SoundFan sound levels are measured in sones. At this time there are no sone level test standards available through HVI due to the fact that remote mounted fan noise levels are in proportion to the following: type of duct, length of duct, fan distance from the intake source and other miscellaneous factors. However, it is generally accepted that remote mounted venting is usually quieter than standard (in room) venting.
TD-MIXVENT SERIES
12
As the name suggests these fans are extremely quiet, low profile “Mixed-flow” fans. Manufactured in plastic material with an external connection box, the body is easily dismantled with a two speed controllable 115V 60Hz motor. Sound waves are directed through the perforated inner skin and absorbed by a layer of sound-absorbent insulation. Plus the TD-SILENT is fitted with rubber gaskets on the inlet and outlet to absorb vibrations.
100XS 150S 200SPolypropylene housing • • •ABS fan blades • • •Thermal link with automatic reset • • •Permanently lubricated ball bearings • • •Speed controllable 2-speed motor • • •
Construction characteristics
Terminal Box
Sound-absorbent cover
Sound Attenuating Liner
External Casing
Rubber Gasket
Mounting Bracket
Support Brackets
General Details of the TD-SILENT RangeGeneral Details of the TD-SILENT Range
13
Easy Maintenance
Low Profile
The low profile of the fans in the TD-SILENT range makes them the ideal
product for installations with low height limits, such as the case of suspended
ceilings.
Bi-material support brackets, which in addition to simplifying installation,
serve as joint seals.
Connection Box Rotates 360°
Connection box can be rotated360º, to facilitate easy connection
of the power cable.
Duct Air-SealsIntegral Mounting
Bracket
Bi-material inlet and outlet incorpo-rating a flexible washer to facilitate installation, absorb vibrations and provide a virtually air-tight seal.
Mounting bracket for installing on a wall or ceiling, incorporating twin-ma-terial support brackets for the motor
section that absorbs vibration.
Low Noise Levels
Sound waves produced inside the TD, are directed through the perforated inner skin and absorbed by the layer of sound-
absorbent material.
TD-SILENT Innovative Design Features
14
1 2
3 4
5 6
Loosen the clamps. Open the clamps on both ends.
Remove the fan body. Remove the terminal box lid.
Connect electrical supply. Re-mount fan body by tightening the clamps.
TD-SILENT Easy Installation
15
Technical SpecificationsWarrantyFive (5) year limited warranty.
RangeThe TD-SILENT consists of four (4) nominal sized in-line fans. All models are specifically designed for direct connection in-line with industry standard diameter round ducting.
ConstructionThe TD-SILENT models 100XS (4” or 5”), 150S and 200S are manufactured in tough reinforced plastic. Sound waves are directed through the perforated inner skin and absorbed by a layer of sound-absorbent insulation. Plus the TD-SILENT is fitted with rubber gaskets on the inlet and outlet to absorb vibrations.
ImpellersThe impeller blades are molded in tough ABS plastic.
MotorsModels 100XS:Single-phase, 120V 60Hz, shaded pole induction asynchronous motor in die cast aluminum. All motors include direct two speed connection and are also suitable for voltage speed control.
• Class l electrical insulation• IP 44 Protection• Class B Motor Insulation• Safety auto reset Thermal Overload Protection (fuse type)• Self-lubricating sleeve bearings.• Suitable for working airstreams up to 104° F (40°C).
Models 150S and 200S:Single-phase induction asynchronous motor, with permanent capacitor and external rotor in die cast aluminum. All models include direct two speed connection and are also suitable for voltage speed control.
• Suitable for working airstreams up to 140° F (60°C).• Class I electrical insulation• IP 44 Protection• Thermal Overload Protection• Class B Motor Insulation• Sealed For Life, ball bearings
Code Approval• All models have been independently safety tested by Underwriters Laboratories, Inc. and are UL and cUL Listed.• Independently tested for Airflow Performance. • The TD product range is certified by the Home Ventilating Institute (HVI) for Air Performance.• All models are ENERGY STAR® qualified.• All models are NAHB - National Green Building Green Approved.
TD-SILENT SERIES
16
Air Performance
ModelDuct Dia.Ins.
Nom.RPM Volts Max.
Watts SpeedCFM v Static Pressure (SP) Ins. WG Max.
The TD-SILENT Models 100XS and 150S are California Title 24 compliant and meet ASHRAE 62.2 when installed with a CVC and other TD models are compliant when installed with a 3 way switch and remotely mounted speed control.
TD-SILENT SERIES
17
V-CEILING MOUNT BATHROOM FAN
Construction• Robust steel housing and duct collar• Heat-sink motor unit• Internal electrical wiring box• Attractive, sturdy grille• Impedance and thermal fuse electrical protection• UL List for installation in tub/shower enclosures when connected to a GFCI protected branch circuit.
* Energy Star qualified data based on tested air flow and power consumption.
Model Duct Dia.
Grille Size (Sq.)
Cabinet Size Unit Wgt./Ship Wgt.
(lbs)W H D
V50 4” 13 x 13 9-7/8 9-7/8 8-1/16 7.7/10.4V80 4” 13 x 13 9-7/8 9-7/8 8-1/16 7.7/10.4V110 4” 13 x 13 9-7/8 9-7/8 8-1/16 7.7/10.4V150 6” 13-5/8 x 13-5/8 12-1/16 12-1/16 9-9/16 12.3/16.2
Performance• The most energy efficient line of ceiling mounted ventilation fans available in North America.• Aerodynamically engineered to move air with lowest power consumption and sound levels. • Motors operate with the lowest heat build up for long life even when run continuously - 5 year warranty.• Low air leakage dampers minimize uncontrolled infiltration.• The lowest carbon footprint of leading residential ventilation brands.
Performance
Dimensions
18
Standard Features• MERV-8 filters• Less than 1 watt stand-by power consumption• Transformer/relay package allowing simple on/off control• Plastic double collars for 6 or 8” direct duct connection (TR300 is 8” only)• 3’ power cord• Integral mounting flange and hanging bracket system• Fully insulated case• Large cores for high efficiency• No condensate pan or drain required• 10-year industry best core warranty• 2-year warranty on balance of unit
unit case=28-3/4W x 20-1/8H x 23-7/8Dcarton=21-1/2W x 32L x 29H
Weight: unit=72 lbs, in carton=85 lbs
Watts - - - 310 300 287 266 247 224 206
Temp Eff % - - - 67 68 69 71 72 76 80
Total Winter % - - - 56 57 58 61 62 67 70
Total Summary % - - - 37 38 39 42 44 48 51
LISTEDDUCTED HEAT
RECOVERY VENTILATOR89S5Performance and Dimensions
Contractor Benefits
• Models compatible to any HVAC equipment• Simple installation• Mount in any orientation• May be installed in unconditioned locations like attics and garages• Easy-to-access field support• Elimination of callbacks• “Green Building” compliant
TR-TOTAL RECOVERY FOR ALL CLIMATES
19
Bat
hroo
m
SOLVED!Bathroom Exhaust Concerns...
We spend hours upon hours in our bathrooms; why not make them as comfortable as possible? No more loud noisy fans that instantly alert you the moment you hit the switch. If the strongest, quietest, bathroom exhaust system is what you seek, look no further. S&P offers a range of inline fans or ceiling mounted fans that offer several advantages over traditional bathroom fans to fit exactly what you need. Our TD-MIXVENT and PV-POWERVENT lines of fans are available in convenient, all inclusive kits to provide the ultimate bathroom ventilation system. Whether you choose from the popular, and exclusive, TD series bathroom exhaust kits (for single or dual venting points), or the ultra powerful PV series kits (also, in single or dual vents) for long or complicated duct runs, all S&P bath kits feature a powerful fan mounted in the attic (away from the living space). The result is a “Turbo” powered fan (much stronger than generally associated with bathroom exhaust) and yet a peacefully quiet operation. If your concern is noise, the TD-SILENT is the fan for you, with a built in sound attenuator and remote mounting the TD-SILENT is the fan you will never hear. You also have the choice of the SWF sidewall series fan, featuring the powerful PV motor, when attic space or easy indoor access is difficult or not suitable for traditional in-line mounting. Finally, if a ceiling mounted fan is what you need, our V-Series bathroom fans, are the most energy efficient line of ceiling mounted ventilation fans available in North America.
Our remote mounted fans are powerful enough to vent multiple areas with one unit (dual vent - dv kits) for today’s larger bathrooms; venting multiple bathrooms with one unit is also possible. The remote mounting feature allows peace and quiet in the living space, thus reducing the sound level of a generally noisy fan. S&P remote fans also offer extended duty times, are low maintenance and help reduce moisture, which decreases the likelihood of mold or mildew. Plus, they do not detract from the homes aesthetics unlike some unsightly roof mounted units. S&P remote fans are the clear choice for the strongest, quietest installation.
In addition to our fans and kits, S&P offers a complete line of grilles and switches. When used in combination S&P offers the perfect solution with the most options!
Your Concern, S&P’s Solution:Long or Complicated Duct Runs with Extreme Static
Pressure Concerns
Economical Concerns andMost Bathroom Exhaust
Extreme Noise Concerns
Limited Access to Duct Climate & IAQ Concerns
PV-POWERVENT SERIES TD-MIXVENT SERIES TD-SILENT SERIES
SWF-SIDEWALL SERIES or V-SERIES TR-SERIES
20
Economical Bathroom Ventilation - TD-MIXVENT• 2 speed motors allow for 2 performance levels with each unit (100% variable speed).• Easy access to motor without dismounting the fan unit.• Easy to install.• Attractive all inclusive kits available.• 5 year warranty.• ENERGY STAR® qualified.• AMCA and HVI
Single Vent with TD Fan Dual Vent with TD Fan
sFaansansforf
Li e!fe
Fans for
Life!
For the most effective bathroom ventilation, HVI recommends eight air changes per hour. Fans should be installed as close to the shower as possible and, if marked as suitable for this location, directly over it to capture the moisture as directly as possible. Your fan should have a control that will allow the fan to run at least 20 to 30 minutes after each shower.
An enclosed toilet should have its own exhaust fan. Fans should be located over the shower or tub. Bathroom doors need to have at least 3/4” clearance to the finished floor to allow entry of makeup air. Using a timer or other control ensures that ventilation continues for a minimum of 20 minutes after use of the bathroom. For steam showers, we recommend a separate fan in the steam room that you can turn on after use. Bathroom (continuous ventilation) should be available on a continuous basis at a minimum of 20 CFM in lieu of an intermittent 50 CFM fan.
Need to meet ASHRAE 62.2 or looking to continuously ventilate your bathroom? You can use our CVC - Continuous Ventilation
Control with any switch you choose! (only available for use with TD fans)
The Perfect Addition
Bathroom
21
Bat
hroo
m
Single Vent Bathroom Exhaust
The TD-MIXVENT fan kits provide all the hardware needed to complete a simple in-line ducted ventilation installation. The kit includes a powerful TD in-line fan, and exterior and interior grilles (with or without lights). Available in both Standard Exhaust Kits, for venting a single location, and Deluxe (Dual) Exhaust Kits, for venting multiple locations with one fan.
The TD-MIXVENT fan kit is the ideal solution for any simple in-line ducted fan installation.
All TD kits have standard 7-year warranty.*
Featuring TD-MIXVENT Kits
Fan Sizing for Bathrooms Under 100 SQ. FT. The following recommendations follow the Home Ventilating Institute (HVI) guidelines:
FAN SIZING FOR BATHROOMS UNDER 100 Sq. Ft. The standard rule for bathrooms 100 square feet or smaller is one CFM per square foot of the bathroom. To find the square footage multiply the length of the bathroom by the width.
Example:10’ x 10’ bathroom =100 square feet.You will need a 100 CFM fan for this bathroom.
Bat
hroo
m
22
IMPORTANT: If venting in a non-insulated attic space, or in a cold climate, insulated flexible duct is strongly recommended for condensation issues.
KIT-TD100XL• 1 TD100x exhaust fan• 1 Vent Light with LED Bulb (VLED-100)• Integral mounting bracket
KIT-TD100XH• 1 TD100x exhaust fan• 1 Vent Light with Halogen Bulb (VLH-100)• Integral mounting bracket
KIT-TD100XF• 1 TD100x exhaust fan• 1 Vent Light with Fluorescent Bulb (VLF-100)• Integral mounting bracket
*Light Bulbs not included in 7 year warranty.
Bathroom
23
Bat
hroo
m
KIT-TD100XL• 1 TD100x exhaust fan• 1 Vent Light with LED Bulb (VLED-100)• Integral mounting bracket
KIT-TD100XH• 1 TD100x exhaust fan• 1 Vent Light with Halogen Bulb (VLH-100)• Integral mounting bracket
KIT-TD100XF• 1 TD100x exhaust fan• 1 Vent Light with Fluorescent Bulb (VLF-100)• Integral mounting bracket
Dual Vent Bathroom Exhaust
Fan Sizing for Bathrooms Over 100 SQ. FT. The following recommendations follow the Home Ventilating Institute (HVI) guidelines:
Ventilation for baths over 100 square feet is calculated based on the fixtures in the bathroom. Allow 50 CFM for each standard toilet, shower, steam shower or tub. Whirlpool, garden and hot tubs are calculated at 100 CFM each. Add the CFM for all fixtures and you’ll have the total CFM required for the bathroom.
Step 1: Calculate Bathroom Size: 20’ x 10’ Bathroom =200 square feet Step 2: 1 Toilet +1 Shower +1 Tub =150 CFM Result: You will need a 150 CFM fan for this bathroom.
KIT-TD150L• 1 TD150 exhaust fan• 2 Vent Lights with LED Bulb (VLED-100)• 1 Y-fitting (SY44-6)• Integral mounting bracket
KIT-TD150H• 1 TD150 exhaust fan• 2 Vent Lights with Halogen Bulb (VLH-100)• 1 Y-fitting (SY44-6)• Integral mounting bracket
KIT-TD150F• 1 TD150 exhaust fan• 2 Vent Lights with Fluorescent Bulb (VLF-100)• 1 Y-fitting (SY44-6)• Integral mounting bracket
Dual Vent TD-KIT Bathroom Exhaust Kits
*Light Bulbs not included in 7 year warranty. IMPORTANT: If venting in a non-insulated attic space, or in a cold climate, insulated flexible duct is strongly recommended for condensation issues.
25
Bat
hroo
m
Quiet Bathroom Ventilation - TD-SILENT• 2 speed motors allow for 2 performance levels with each unit (100% variable speed).• Easy access to motor without dismounting the fan unit.• Easy to install.• 5 year warranty.• ENERGY STAR® qualified.• HVI
sFaansansforf
Li e!fe
Fans for
Life!
Ventilation that is Out-of-Sight and Out-of-Mind...
+ =When you use our TD-SILENT series with our VL-Vent Light you get ventilation that is “Out-of-Sight and Out-of-Mind”! The Vent Lights appear to be a regular can light, and when combined with a remotely mounted TD fan, the noise and unsightly look of the traditional bathroom fan are gone! The Vent Lights are aesthetically pleasing grilles with lights that will match any bathroom decor.
Duct Air-Seals
Bi-material inlet and outlet incorpo-rating a flexible washer to facilitate installation, absorb vibrations and provide a virtually air-tight seal.
Low Noise Levels
Sound waves produced inside the TD, are directed through the perforated inner skin and absorbed by the layer of sound-
absorbent material.
Innovative Features
26
Bathroom
CVC Model
TD Fan Size Application Max.
FlowContinuous
Flow @ .25”SPCVC-100 100 Single Inlet 101 CFM 20 CFMCVC-100x 100x Single Inlet 135 CFM 20 CFM
S&P’s CVC allow a new or existing bath fan to run continuously on a low speed. In conjunction with an S&P TD fan a CVC will immediately improve the air quality in the home and reduce the damaging effects of moisture and mold.
The CVCs are designed to meet the requirements of ASHRAE 62.2 and the International Residential Code. In areas where ASHRAE 62.2 is not a requirement the CVC is still an economical choice to improve indoor air quality.
Features• Reduces remodeling costs, helps meet ASHRAE 62.2 requirements• Perfect for homes, apartments, dorms, hotels and elderly housing• Economical and easy to install in your existing wall box• Works with most fan controls, i.e. motion sensors, timers, speed controllers.• Improves the indoor air quality in your home• Undetectable, efficient and effective• Operates with any standard switch• No programming required• 120V, 60 Hz, 3A Maximum
Attaches to any standard wall switch.
Simple 2 wire connection across the wall switch and fits into most standard wall/
junction boxes.
Completely installed in minutes!
1 2 3Easy Installation. . .
Dimensions in Inches (mm)
27
Bat
hroo
m
Inline Bathroom Ventilation- PV Fans• Epoxy coating on inside and outside of fan housing.• Fully speed controllable• Perfect for higher static pressure applications• Extra long inlet and discharge collars make installation quick and trouble free. • Supplied with a strong galvanized steel mounting bracket.• All inclusive kits available• AMCA, HVI certified, and cULus Listed.• ENERGY STAR® qualified on sizes 150X and larger.• 5 year warranty.• Line includes 4 - 12” 108 - 942 CFM.
S&P PV-POWERVENT Series fans are also available as easy-to-install kits. This ultra powerful bathroom fan offers a choice of single or dual vent exhaust. These kit are used for installations that require long or complicated duct runs. All PV kits have a standard 8-year warranty.
A Tip from S&PWe recommend the use of Insulated Flexible ducting. This will help reduce sound levels and is better for cold weather climates.
31
Bat
hroo
m
Features:• Longer duct collar for 4” duct • Extendable hanger bars up to 24”• 7.5” grille• Built-in backdraft damper• 3 bulb options
7” sq.
5.25”
9”
13”-24”
2.25”
Dimensions (inches)
Model DescriptionVLED-100 Vent Light with PAR30 LED BulbVLH-100 Vent Light with PAR30 Halogen BulbVLF-100 Vent Light with Energy Star Rated Compact Fluorescent Bulb
Vent LightsAvailable with LED Bulbs
Featuring Vent Lights and Premium GrillesS&P’s Grille Options give you the choice of seven (7) aesthetically pleasing grilles designed to match any bathroom decor. You can choose from our Vent Lights, Premium Grilles or Adjustable Grilles to fit your needs.
These grilles are designed to be used exclusively with one of S&P’s remotely mounted inline fans (TD, PV, SWF) for virtually silent bathroom ventilation. Inline fans give you the option to mount your grille over the shower, toilet, tub, or in multiple locations (dual vent).
With S&P’s Grille Options the choice is yours!
Why Choose the Vent Light with LED Bulbs?
S&P’s respect for the environment extends to its Vent Lights with the optional LED Bulb. The benefits to the LED Bulbs include:
• Built to last a minimum of 60,000 hours, plus the LED’s use a fraction of the energy that a traditional incandescent or halogen lamp uses• LED’s contain no mercury so they are easy to dispose of, unlike other energy efficient bulbs• The LED lamps run cool and are shock resistant, making them safer for use in your home
Bathroom Exhaust Grilles
S&P’s Vent Lights give you ventilation that is “Out-of-Sight and Out-of-Mind”! The Vent Lights appear to be a regular can light, and when combined with a remotely mounted fan, the noise and unsightly look of the traditional bathroom fan are gone! The Vent Lights are aesthetically pleasing grilles with lights that will match any bathroom decor.
32
Bathroom Model Description
PG-100 4” Plastic Grille with 4” Steel CollarPGD-100 4” Plastic Grille with 4” Steel Collar and Integrated Backdraft DamperPG-150 6” Plastic Grille with 6” Steel CollarPGD-150 6” Plastic Grille with 6” Steel Collar and Integrated Backdraft Damper
PG PGD
Grille Dia. Height Fits Duct Dia. Fits Collars
PG-150G 8 1/8 1 5/8 6” PG-150D or PGD-150DBPG-100G 4 5/8 1 1/2 4” PG-100D or PGD-150DB
S&P’s premium grilles come standard with steel collars for easy mounting and installation. They are available with (PGD) and without (PG) backdraft dampers.
Premium Grilles
Adjustable Grilles
Exhaust grilles for bathrooms, toilets and other small rooms. All models offer an adjustable central valve to regulate the airflow.
Options for Remodeling or RetrofitAre you sick of your noisy bathroom exhaust fan? Reduce the noise of your existing bath fan (while increasing performance) use our SWF-SIDEWALL fan! Move the fan motor outside to reduce noise. The SWF fan is designed to mount seamlessly on the outside of your house and allows you to connect to your existing fan housing or grille. The SWF is also perfect when space is an issue or direct venting to the outside is required.
SWF-SIDEWALL Fan
• Same powerful motor found in PV series fans.• Low profile aesthetic design.• Fully speed controllable.• Built-in backdraft damper .• Extended opening exhaust grille.• 5 year warranty.• HVI certified and cULus listed.• Line includes 4 - 8” 119 - 416 CFM
sFaansansforf
Li e!fe
Fans for
Life!
35
Bat
hroo
m
Performance• The most energy efficient line of ceiling mounted ventilation fans available in North America.• Aerodynamically engineered to move air with lowest power consumption and sound levels. • Motors operate with the lowest heat build up for long life even when run continuously.• 5 year warranty.• Low air leakage dampers minimize uncontrolled infiltration.• The lowest carbon footprint of leading residential ventilation brands. Construction• Robust steel housing and duct collar• Heat-sink motor unit• Internal electrical wiring box• Attractive, sturdy grille• Impedance and thermal fuse electrical protection• UL List for installation in tub/shower enclosures when connected to a GFCI protected branch circuit
S&P’s V-Series Bathroom Fan by RenewAire is the best choice for exhaust-only ventilation. The V-Series improves indoor air quality and increase’s your homes durability by quickly exhausting contaminants and excess moisture that can cause health issues, mold growth and structural damage.
Ceiling Mounted Fans - V-Series
sFaansansforf
Li e!fe
Fans for
Life!
The VSWITCH Control is specifically designed for use with the V-Series fans. This Line Voltage Ventilation Fan Control may be used to comply with ASHRAE 62.2 ventilation rates for residential applications.
VSWITCH Control
V-Series Exclusive AccessoriesRadiation Damper
The V-Series Radiation Dampers are designed to meet local codes that require fans installed in fire rated ceilings to be protected by dampers which are insulated against both heat and flames.
These are UL Classified radiation dampers rated at 1, 2 or 3 hours of fire resistance.
V-Series Fan
Radiation Damper
Hanging Bar
Grille
36
Range H
ood
SOLVED!Range Hood Exhaust Concerns...
Today the kitchen is the heart of our homes, it’s where we relax, gather and enjoy family and friends. S&P offers a range of inline fans to fit your range hood needs by offering many advantages over traditional (in hood) fans. By virtue of the remote mounting, the noise is kept further from the living space, reducing the sound level of the fan. Remote mounting also allows for a duct silencer (SIL) to be mounted between the fan and the range hood, reducing the fan noise level by another 50% or more. S&P remote fans also offer extended duty times, low maintenance, and do not detract from the homes aesthetics, unlike some unsightly roof mounted units. S&P remote fans are the clear choice for the strongest, quietest installation.
Fans Accessories
* A grease filter in the range hood is required to use an S&P Inline Fan in this application
37
Ran
ge H
ood
How to Size Your Kitchen Ventilation SystemDue to varying capacities for moving air, prior to selecting your range hood fan, be sure to consult with local residential codes and the range manufacturer’s recommendations. If you are unable to determine any manufacturer’s recommendation, S&P has provided the following illustration to assist you with accurately calculating your fan size.
The following recommendations follow the Home Ventilating Institute (HVI) guidelines:
HVI’s recommended kitchen range hood ventilation rates vary and depend on the type of cooking performed. The minimum rates are 40 CFM per lineal foot for a kitchen range hood placed along a wall and 50 CFM per lineal foot for island hoods. However, HVI recommends 100 CFM per lineal foot for wall-mounted kitchen range hoods and 150 CFM per lineal foot for island kitchen range hoods. Kitchen range hoods equipped with multiple speed settings allow low-level, quiet ventilation for light cooking with the ability for effective ventilation when needed. For “professional” style cook-tops, HVI recommends following the cook top manufacturer’s advice to estimate the approximate CFM requirements.
Wall Mount Installations:100 CFM per foot of width.
Example: 48” (4 ft.) wide hood will require 400 CFM.
Feet of Width 4 CFM per Foot x 100Air Flow [CFM] 400
Island Mount Installations:150 CFM per foot of width.Example: 48” (4 ft.) wide hood will require 600 CFM.
Feet of Width 4CFM per Foot x 150Air Flow [CFM] 600
48
48
40
Range Hood Exhaust
S&P’s Range Hood Exhaust Fans are California Title 24 compliant and meet ASHRAE 62.2 when installed with 3 way switch and remotely mounted speed control.
RC-Roof CapGalvanized steel roof caps with damper flap closure. Duct sizes from 4” to 10”.
Model A B C D E F G Wgt. (lbs)
RC-4 6150
6150
3 1/2
9012
30012
3004 1/2
1152 1/2
60 1
RC-6 8200
8200
4100
14355
14355
5125
4100 1
RC-8 8200
8200
4100
14355
14355
5125
4100 1
RC-10 11280
11280
5125
17430
17430
7175
4100 1
Dimensions in inches/mm
ACOP-Vent Mounting ClampManufactured from galvanized steel with an insulated rubber duct seal. These clamps facilitate the connection and disconnection of round ventilation ducts. All models incorporate internal
hanging tabs for suspending the ducting / fan when horizontally mounted.
Model Description Wgt. (lbs)
ACOP-V100 4” Connector clamps (2 ea., sold in pairs) 1ACOP-V125 5” Connector clamps (2 ea., sold in pairs) 1ACOP-V150 6” Connector clamps (2 ea., sold in pairs) 1ACOP-V200 8” Connector clamps (2 ea., sold in pairs) 1
SIL-Sound AttenuatorThe galvanized steel silencer is used for kitchen range hood ventilation and other applications where noise is a concern. The S&P silencer reduces the “actual” sound level of the kitchen ventilation system by 50% or more. They feature rubber seals on inlet and outlet.
Model A B C D Wgt. (lbs)
SIL-125 5125
9 13/16
25027 9/16
70035 7/16
900 15
SIL-150 6 5/16
1609 13/16
25027 9/16
70035 7/16
900 18
SIL-200 7 7/8
20012 3/8
31527 9/16
70035 7/16
900 21
SIL-250 9 13/16
25014
35527 9/16
70035 7/16
900 32
SIL-315 12 3/8
31515 3/4
40027 9/16
70033 7/8
860 32
Model A B Wgt. (lbs)
CAR-100 1003 15/16
803 1/8 1
CAR-125 1254 15/16
1003 15/16 1
CAR-150 1505 7/8
1204 3/4 1
CAR-200 2007 7/8
1405 1/2 1
CAR-250 2509 13/16
1405 1/2 2
A
Dimensions in mm/inches
Dimensions in inches/mm
CAR-Backdraft Damper
Range Hood Exhaust Accessories
Backdraft dampers are designed with galvanized steel collars and have lightweight aluminum damper blades. They are spring loaded for positive closure.
B
40
If you have a dryer with long or complicated duct runs, S&P offers the perfect solution to increase dryer efficiency: the PV100x Dryer Booster Fan. The PV100x has been specifically designed to handle dryer boosting applications when overcoming long or complicated duct runs. This system helps save on drying time, moisture build-up, wear and tear on your dryer, and helps save on your electric bill. The centrifugal blade design is able to overcome extreme resistance from the most challenging installations. The PV-100x offers a fully enclosed motor with Class F insulation which ensures a long, trouble free life; thus making it the right choice for enhancing the performance of your clothes dryer.
The PV-100x fan is available separately or as part of a kit that includes everything necessary for a hands-free operation. Once the system is installed you will no longer waste time, energy or unnecessary wear and tear on your dryer. The next step is to select which activation best fits your needs.
How to activate the PV-100x fan for clothes dryer boosting
Pressure SwitchesPressure switches are a viable method of fan activation and a good solution for many installations. The pressure switch senses the pressure differential in the duct created by the dryer operation, thus activating the fan. Conversely, when the dryer is deactivated, the pressure switch senses this differential and the fan is deactivated. S&P’s PV-100xps utilizes a compact pressure sensor and run timer enclosed within the junction box and mounted to the fan housing. The pressure sensor is also available as an accessory.
Current SensorsCurrent sensors are S&P’s “preferred” method of activation. They are “fail-safe”, as there is no maintenance required on the current sensor and they’re easy to install. The current sensing device can be installed at the outlet (where the dryer plugs into the wall) or at the circuit breaker box. When the device senses current going to the dryer, it activates the fan and vice-versa. No thought! No maintenance! Our choice!
InterlocksInterlocks, like Current Sensors, are another “fail-safe” method of clothes dryer booster activation. The interlock senses when the fan is running and activates the dryer. Used as a safety feature, if the fan is not running or if there is a problem with the fan the dryer will not turn on.
All 3 activation methods are available as accessories or in the S&P’s all inclusive dryer booster kits.
NOTEThe PV-100x Dryer Booster fan is suitable for use with duct runs of up to 105 linear feet of 4” rigid duct or a maximum of 6 elbows and 80 feet.
SOLVED!Clothes Dryer Boosting Concerns...
The sidewall unit can be paired with a current sensor or pressure switch when interior duct access in a home, apartment or townhouse is limited or difficult. The expanded exhaust grille allows for the easy passing of lint laden air. The SWF utilizes the same powerful motor as the PV-100x and is also suitable for duct runs up to 105 feet or up to 80 feet with 6 elbows. The low profile SWF fan is easy to install with an epoxy coating that can be painted to match the exterior of the building. The SWF also offers the same trusted 5 year warranty.
SWF - Sidewall Mount Exhaust Fan for Dryer Boosting
PV-100xps
DBF-100xc
IL-115/230
SWF100x
Clothes D
ryer
41
Featuring S&P’s SWF-SIDEWALL SeriesGasoline, automotive exhaust fumes, paint, fertilizer, pesticides and other potentially harmful products are present in most garages and the effect on the quality of air inside the home is undoubtedly compromised if not properly addressed. Keep the hazardous fumes in your attached garage from entering your home and harming you and your family with the SWF Series fans. S&P’s Garage Ventilation solutions help keep the contaminants in your garage from harming you and your family!
The SWF Series’ outdoor rated exterior housing provides easy access from the outside of a building or dwelling. This makes the SWF a great solution for installations where attic space or easy indoor access is difficult and not suitable for traditional PV style in-line mounting. The Sidewall Fan Series (SWF) of direct drive
centrifugal ventilation fans consists of five model sizes: 4” through 8”. All models are designed for direct connection in-line with standard diameter round ducting. Airflow performance values range from 119-416 CFM.
You can also use S&P TD-MIXVENT, TD-SILENT or PV-POWERVENT for your garage ventilation needs.
SOLVED!Garage Ventilation Concerns...
TD-MIXVENT PV-POWERVENTTD-SILENT
Gar
age
42
Indoor Air Quality Concerns...For Your FamilyToday’s homes are built to be tighter and more energy efficient than ever before. Builders and homeowners use vapor barriers, caulking, and better sealed doors and windows to reduce energy loss caused by air infiltration. Tighter homes also mean that pollutants are trapped indoors. Poor indoor air quality, caused by trapped pollutants, is not
only uncomfortable to the occupants, but it is a health hazard. Volatile Organic Compounds (VOCs) like formaldehyde, as well as cigarette smoke, radon, household cleaners, and perfumes can threaten your family’s well being.
For Your HomeEveryday activities such as showering, cooking, doing laundry, even breathing are just a few ways that moisture is generated in your home (one gallon per person, everyday). Moisture that is trapped in your home can lead to structural damage. Signs of structural damage include heavy condensation on windows, water damage on window sills and molds forming in cold corners of the home.
Whether you have a new home under construction or an existing home needing a ventilation upgrade, S&P provides powerful, quiet blowers in its TR (total recovery) Series for all climates. You can enjoy ample air exchange without the objectionable noise associated with lower quality products. If you want the best “whole house” approach to efficient and effective ventilation, S&P’s TR Series makes your choice simple.
“Whole House” Ventilation Made Easy!
IAQ
43
Protect Your Family & Your HomeTo protect the two most valuable investments of your life, your home and your family, improving indoor air quality is key. With S&P’s TR (total recovery) Series for all climates, stale room air is exhausted and fresh outdoor air is brought back into the house. These two air streams are directed through a highly developed “air-to-air” energy exchange core. The air streams are physically separated by many layers of “plates” so there is no mixing or contamination of the fresh air. The plates are made of an engineered “resin” material that simultaneously transfers heat by conduction and humidity by attracting and moving water vapor from one air stream to the other.
S&P’s TRs moderate extremes in both temperature and humidity, creating a comfortable indoor environment. The unique moisture transfer capability of the S&P core also eliminates condensation and frost build up in most applications. Unlike other ERVs on the market no mechanical or electrical defrost systems are needed, which means higher heat recovery efficiencies, easier installation and more reliable operation.
SOLVED!Indoor Air Quality Concerns...
The CORE• Efficient transfer of heat and moisture• No liquid is accumulated; no drain pan or defrost mechanism is required!• Industry best 10-year warranty
• Contaminated air is exhausted from your home, while the static plate core regulates extremes in humidity
IAQ
44
IAQ
Series TR - The Ultimate ERV for ALL Climates
The Difference Between ERVs and HRVs
ERVs• Transfer BOTH heat AND humidity• Use enthalpic core• S&P’s TR is an ERV
Energy Recovery Ventilators (ERV) and Heat Recovery Ventilators (HRV) both moderate extremes in ventilation air temperature so what is the difference?
HRVs• Transfer ONLY heat• Use aluminum core or simple plastic cores
Can ERVs be used in climates subject to cold winters?
Yes! Because ERVs transfer both heat and humidity they are the perfect choice for any climate. In the winter ERVs:
• Warm outdoor air close to room temperature • Use heat that would otherwise be lost with the exhaust air. • Transfer water vapors to moderate extremes in humidity levels • Help prevent moisture damage or over-drying of the home.
Why are ERVs better than HRVs?
HRVs and ERVs are similar in that they both:• Improve Indoor Air Quality• Moderate extremes in ventilation temperature• Use heat that would otherwise be lost with the exhaust air in the winter• Provide necessary fresh air while pre-cooling in the summer
Why is S&P’s Series TR the Ultimate ERV?
ONLY ERVs have the ability to transfer water vapors or moisture so they:• Help prevent over-drying of the home in colder seasons• Lessen the demand on the air-conditioning system in warmer seasons• Are typically 3x more energy efficient in the summer than products (or units) that transfer only heat (HRVs)
Q:A:
Q:A:
Q:A:
Q:A:S&P’s TRs provide the same benefits as other ERVs on the market. Major Series
TR advantages include:• More heat transfer than most HRVs• More humidity control than other plate exchangers• Simplicity and positive airstream separation not offered by wheel type ERVs• 10-year core warranty
45
IAQ
Can ERVs be used in climates subject to cold winters?
Why are ERVs better than HRVs?
The Perfect Pair
To get the most efficient and effective general ventilation system available use a TR with S&P’s exclusive TD-MIXVENT inline fans for bathroom exhaust.
General VentilationBathroom exhaust fans are also required
Bathroom fans as required for point source exhaust. S&P’s TD Mixvent inline fan makes the perfect choice.
S&P TR draws room air from air handler return air duct system.
Energy efficient homes can trap indoor air pollutants.
Air polluter
S&P TR70Return-air plenum
After transferring its heat inside the TR, stale air is ex-hausted outside.
Outside-air intake draws fresh air into the TR, where it is tempered before it enters the return-air plenum.
Use one of S&Ps Inline Centrifugal fans (SWF shown) for a silent Range Hood Exhaust.
Central ExhaustYour BEST choice for green ventilation, Series TR exhausts stale air, brings in fresh air and saves energy year-round.
Series TR• Replaces bathroom exhaust fans• 20 CFM continuous per bathroom• 50 CFM intermittent per bathroom• Meets ASHRAE 62.2 when used with one of S&P’s Percentage Timer Controls• Other possible exhaust locations: kitchen area (cannot exhaust range hood), utility room, smoking room, hobby room, etc.• Small duct work system to collect air from each exhaust location• Fresh air may be supplied to furnace (AC) return air duct• Optional automatic proportional runtime control and push button control available
Energy Recovery Applications
S&P TR prevents win-dow condensation.
S&P TR moderates extremes in both heat and humidity year round.
Air polluter
Return-air plenum
After transferring its heat inside the TR, stale air is ex-hausted outside.
Outside-air intake draws fresh air into the TR, where it is tempered before it enters the return-air plenum.
A Central Exhaust system replaces bathroom exhaust fans.
S&P TR draws room air from places that are to be exhausted to outside.
Use one of S&Ps Inline Centrifugal fans (SWF shown) for a silent Range Hood Exhaust.
46
IAQ
Energy Recovery Controls & Sizing
SPTL - Percentage Timer Control• Primary control for TR70, TR130, TR200 and TR300• Runs unit an adjustable amount of time each hour• Two wire, low voltage connection to TR• Meets ASHRAE 62.2 continuous ventilation standards
SPBL - Push Button Point-of-Use Control• Push button control turns on unit from bathrooms or other intermittent exhaust locations• 20 minute run-time with one touch• Push 2x for 40 or 3x for 60 minutes• Two wire, low voltage connection to SPTL
SFM - Percentage Timer Control with Furnace Interlock• Alternate primary control for TR70, TR130, TR200 and TR300• Wires to TR unit and either thermostat or furnace control to turn on furnace blower• Six wire, low voltage connection• Meets ASHRAE 62.2 continuous ventilation standards
SHW-20 - Dehumidistat• Rotary dial dehumidistat• Turn the dial to set desired humidity level• Designed for convenient installation in bathrooms, kitchen or laundry room• Dehumidifies when inside air is more humid than the set point• Caution: the outside air must be less humid than the indoor air for this to work.
Choosing the correct size TR for your home is easy, all you need to know is the square footage.
If you home is up to:1500 Sq. Ft. you need a TR702700 Sq. Ft. you need a TR1304000 Sq. Ft. you need a TR2006000 Sq. Ft. you need a TR300
Choosing the Right Size TR
47
IAQ
Choosing the Right Size TR
Improves Indoor Air QualityBy providing simultaneous exhaust and fresh air supply, S&P reduces the concentration of harm-ful pollutants in indoor air - an absolute must in schools, offices and smoking environments.
Meets Ventilation Codes for Air ExchangeProvides ample ventilation to meet ASHRAE 62 and the International Mechanical Code that now requires two to three more air exchanges than in the past.
Controls Excess MoistureUnlike conventional ventilation or basic heat ex-changers, S&P moderates not only the tempera-ture but the humidity content of incoming air, limiting humidity swings and associated biologic growths.
Optimum Cold Weather PerformanceRecaptures heat otherwise lost to exhaust air while controlling humidity extremes. This greatly reduces the demand on heating equipment - low-ering both initial costs and energy bills. Also pro-tects heating coils from freeze damage.
Optimum Warm Weather PerformancePre-cools and dehumidifies the fresh airstream by transfer of heat and humidity to the exhaust air-stream. This greatly reduces air conditioning de-mand - lowering both initial costs and energy bills. On retrofits, the ventilation rate of existing A/C equipment can be as much as doubled.
Energy Saved = Dollars SavedS&P’s all-weather performance can cut annual en-ergy bills for heating, cooling and dehumidification of ventilation air by 50% or more.
Sensible HeatThe amount of energy involved in raising or lowering the temperature of air not including any energy required to cause water vapor to change state.
Latent HeatThe amount of energy associated with the humidity (or water vapor content ) of an air stream. A drier air stream contains less latent heat and will impose a smaller latent load on the air conditioner.
EnthalpyThe total amount of energy contained in air, the sum of sensible and latent heat.
Balanced VentilationA ventilation strategy using both an exhaust air blower and a supply or make-up air blower that does not pressurize or de-pressurize a build-ing.
Air-to-Air Heat ExchangerGeneric term for technologies designed to transfer heat -- and sometimes moisture -- be-tween two air streams.
Heat Recovery Ventilator – HRVAn air-to-air heat exchanger that transfers sen-sible heat only; no humidity (latent heat) trans-fer occurs between the two air streams.
Energy Recovery Ventilator – ERVIn Cold Weather, some of the humidity in the inside air is recovered – along with its latent energy. Non-enthalpic heat recovery systems lose that latent energy.