Top Banner
SIKA MODIFIED BITUMEN TECHNOLOGY FOR WATERPROOFING Sika India Pvt. Ltd. 601, A Wing,Infinity Tower Off. Link Road, Malad (W) Mumbai : 400 064 Tel : +91 22 4038 4038 Fax : +91 22 4038 4039 E-mail : [email protected] Website : ind.sika.com Sika Solutions for Every Construction Concrete Waterproofing Refurbishment Flooring Sealing & Bonding Roofing SIKA - THE CUSTOMISED SOLUTION PROVIDER Sikas innovative ideas and expertise in evolving quality products has been a hallmark in the history of construction chemicals. From hundred years Sika is consistently serving the construction industry with its pioneering technology and commitment.
2

Sika Modified Bitumen Technology for Waterproofing · SIKA MODIFIED BITUMEN TECHNOLOGY FOR ... overlaps should be a minimum of 80 to 100 mm and end overlaps 150 mm. ... Sika Modified

Sep 20, 2018

Download

Documents

nguyenkhue
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Sika Modified Bitumen Technology for Waterproofing · SIKA MODIFIED BITUMEN TECHNOLOGY FOR ... overlaps should be a minimum of 80 to 100 mm and end overlaps 150 mm. ... Sika Modified

SIKA MODIFIED BITUMEN TECHNOLOGY FOR WATERPROOFING

Sika India Pvt. Ltd.601, A Wing,Infinity TowerOff. Link Road, Malad (W)Mumbai : 400 064Tel : +91 22 4038 4038Fax : +91 22 4038 4039E-mail : [email protected] : ind.sika.com

Sika Solutions for Every Construction

Concrete Waterproofing

Refurbishment Flooring

Sealing & Bonding Roofing

SIKA - THE CUSTOMISED SOLUTION PROVIDER

Sika�s innovative ideas and expertise in evolving quality products has been a hallmark in the history of construction chemicals. From hundred years Sika is consistently serving the construction industry with its pioneering technology and commitment.

Page 2: Sika Modified Bitumen Technology for Waterproofing · SIKA MODIFIED BITUMEN TECHNOLOGY FOR ... overlaps should be a minimum of 80 to 100 mm and end overlaps 150 mm. ... Sika Modified

Advantages

Intoduction

Sika�s APP/ Plastomeric Bituminous waterproofing membranes are manufactured from a rich mixture of bitumen and selected polymers blended together to obtain excellent heat resistance, flexibility and durability. Modified bitumen membranes have a dimensionally stable carrier to obtain excellent tensile strength, tear and puncture resistance.

UsesIt is used as waterproofing /damp proofing membrane for protection of various substrates in wide range of applications. Medium to large roof slabs ( domestic, commercial and industrial) Basements and raft slabs Exposed roofs (Mineral finish membranes) Underground car parks etc. Bridges & Underpass

Easy to apply Minimum water absorption Easy to install by torching method Long term flexibility Excellent water tightness High tensile strength, tear and puncture resistance Capable of withstanding thermal and structural stresses Highly durable under long term aging

Surface Preparation :Concrete, mortar surfaces must be clean, free from grease, oil, and loosely adhering particles.

Application Method / ToolsApplication procedure may vary slightly depending upon site conditions. However, general guidelines are as follows.Apply solvent / water based primer to a clean, smooth and dry surface by brush, roller or spray. Unroll, align and re-roll correctly before torching. Use gas burner to heat the substrate and thermo fusible film on the underside of the membrane. When the thermo- fusible film melts after torching, the membrane is ready to stick. Roll forward and press firmly against the substrate to bond. Heat the round tipped trowel and use the same to smoothen and press the seam to overlap. Side overlaps should be a minimum of 80 to 100 mm and end overlaps 150 mm.All angles and abutments should be sealed with extra care to ensure full bondage. The edges should be sealed well into the grooves.The membrane should be protected from getting damaged due to ongoing site activities. During backfilling either by cement sand plaster or other suitable methods.

Application Instructions

Storage ConditionsRolls must be stored in their original package, in vertical position and under cool and dry conditions. They must be protected from direct sunlight, rain, snow and ice, etc.

Sika, the global leader in construction chemicals, is reinforcing its commitment towards building ever efficient infrastructure. To achieve this, goal, Sika has been continuously pursuing innovative technologies. Sika India strives to offer a wide range of waterproofing products and significant step towards that is the acquisition of Texsa India. Texsa India, previously a part of Texsa Group and a force to reckon with in the Modified Bitumen membrane segment has state-of-the-art production facility in Manda, Jaipur (India). Sika at the Manda factory produces one of the finest specimens of Modified Bitumen membrane thereby reinforcing its leadership position manifold. Through the acquisition of Texsa India, Sika has laid hands on a treasure trove of more than 50 years of rich experience in the Modified Bitumen technology. Today, Sika India is geared up to supply several varieties of the finest produce of APP bitumen membranes for waterproofing solutions. Each of these membranes guarantees superior and consistent quality catering to the diverse needs of the market. If you have a waterproofing requirement, we have Modified Bitumen membranes!

Sika�s APP Technology

Packaging 1.0 x 10 m roll

Finishes Plain, mineral

Membrane Types

3mm, 4mm, 4kg, 5kg, etc. Polyester or glass fibre reinforcement

Sika APP Membrane system

Podium &Terrace Garden

Basement Waterproofing

Below Over DeckInsulation

RoofWaterproofing

THE SIGNIFICANCE OF POLYMER MODIFICATION

Bitumen

Polymer

Before phase inversionBitumen �Continuous phase Polymer � Dispersed phase

Bitumen

Polymer

After phase inversionBitumen �Continuous phase Polymer � Dispersed phase