4527 Brittmoore | Houston, Texas 77041 | +1 (281) 324-0558 | [email protected] | www.thesubsea.com © 2012, The Subsea Company Ideas, Innovation and Implementation Signature Tester Typical BOP Test Applications SUBSEA BOP EQUIPMENT OPERATOR RELATED FAILURE FAILURE RESULT IMPORTANCE SIGNATURE TEST Wellhead Connector Cannot or difficult to unlock Lost rig time, possible lost well due to cutting off wellhead High Unlock signature test and back driving test LMRP Connector Cannot or difficult to unlock Lost riser string if can not release during drift off High Unlock signature test and back driving test Locking Mini-Collets Cannot or difficult to unlock Severe damage to subsea BOP Low Unlock signature test and back driving test Annular Type Blow Out Preventers Leak, possible difficulty with annular fully opening subsea Usually repairs are made after well completion. Sometimes the BOP has to be pulled Low Close and open signature test with pressure test; observe annular to make sure it relaxes Ram Blow Out Preventers Cannot or difficult to unlock Can not open the rams resulting in substantial downtime. Potential for well control incident High Lock and unlock full-function signature test Subsea Valves Broken fail-safe spring Loss of fail-safe capability Low Signature test open port will confirm spring function; test will show spring and gate condition
1

Signature Tester Typical BOP Test Applications - The Subsea

May 22, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Signature Tester Typical BOP Test Applications - The Subsea

4527 Brittmoore | Houston, Texas 77041 | +1 (281) 324-0558 | [email protected] | www.thesubsea.com

© 2012, The Subsea CompanyIdeas, Innovation and Implementation

Signature Tester

Typical BOP Test Applications

SUBSEA BOPEQUIPMENT

OPERATORRELATEDFAILURE

FAILURERESULT

IMPORTANCE SIGNATURE TEST

WellheadConnector

Cannot or diffi cult to unlock

Lost rig time,possible lost well due to cutting off wellhead

High Unlock signature test and back driving test

LMRP Connector

Cannot or diffi cult to unlock

Lost riser string if can not release during drift off

High Unlock signature test and back driving test

Locking Mini-Collets

Cannot or diffi cult to unlock

Severe damage to subsea BOP

Low Unlock signature test and back driving test

Annular Type Blow Out Preventers

Leak, possible diffi culty with annular fully opening subsea

Usually repairs are made after well completion. Sometimes the BOP has to be pulled

Low Close and open signature test with pressure test; observe annular to make sure it relaxes

Ram Blow Out Preventers

Cannot or diffi cult to unlock

Can not open the rams resulting in substantial downtime. Potential for well control incident

High Lock and unlock full-function signature test

Subsea Valves Broken fail-safe spring

Loss of fail-safe capability

Low Signature test open port will confi rm spring function; test will show spring and gate condition