Report No.: EMC1909073 File Reference No.: 2019-09-21 Applicant: Mid Ocean Brands B.V. Product: Pen Holder/Falshlight/Phone Holder Trademark: N/A Model No.: MO9317 Vendor code: 109979. Test Standards: EN 55032: 2015 EN61000-3-2:2014 EN 55035: 2017 EN 61000-3-3: 2013 Test Result: The EMC testing has been performed on the submitted samples and found in compliance with council EMC Directive 2014/30/EU. Approved By Terry Tang Manager Dated: September 21, 2019 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected]
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Report No.: EMC1909073 Page 2 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Special Statement:
The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19.
The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAS. This approval result is accepted by MRA of APLAC.
Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01
accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of testing Laboratories.
FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the
(FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189.
Industry Canada (IC) —Registration No.:5205A
The EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 5205A.
A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory
Report No.: EMC1909073 Page 3 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
TABLE OF CONTENT
Test Report Conclusion
Special Statement
Content
1.0 General Details………………………….……..…………………….…………. ………… 5
1.1. Test Lab Details……………...………………………...…………………………………… 5
4.4 Harmonic Current Emission Test……………..…………………………………………….. 21
4.5 Voltage Fluctuations &Flicker Test…………...……………………………………………. 23
Report No.: EMC1909073 Page 4 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
5.0 Immunity Test …………………………………………………………………………….. 24
Report No.: EMC1909073 Page 5 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
1.0 General Details
1.1 Test Lab Details
SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan
District, Shenzhen, China
Tel: +86 755 83448688 Fax :+86 755 83442996
Test Location
All tests were performed at:
SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan
District, Shenzhen, China
Tel: +86 755 83448688 Fax :+86 755 83442996
1.2 Applicant Details
Applicant: Mid Ocean Brands B.V.
Address: 7/F, Kings Tower, 111 King Lam Street, Cheung Sha Wan, Kowloon, Hong Kong
Telephone: --
Fax: --
Manufacturer: Mid Ocean Brands B.V.
Address: 7/F, Kings Tower, 111 King Lam Street, Cheung Sha Wan, Kowloon, Hong Kong
Telephone: --
Fax: --
1.3 Description of EUT
Product: Pen Holder/Falshlight/Phone Holder
Brand Name: N/A
Vendor code: 109979.
Model Number: MO9317
Adding Brand Name: N/A
Adding Model Number: N/A
Rating : --
Report No.: EMC1909073 Page 6 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
1.4 Submitted Sample(s)
1 Samples
1.5 Test Duration
Date of Receipt of Test Item: September 10, 2019
Date of Receipt of Test Item: September 10, 2019
Date of Test: September 10, 2019 ~ September 21, 2019
1.6 Additional information of EUT
Submitted Not Available
User Manual
Part List
Circuit Diagram
Printed circuit board[PCB]
Layout
Block Diagram
1.7 Test Engineer
The sample(s) tested by
Print Name: Leo Lau/ Engineer
This test report is not valid without personnel’s signatures of SHENZHEN TIMEWAY TESTING
LABORATORIES.
Report No.: EMC1909073 Page 7 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
2.0 List of Measurement Equipment
2.1 Conducted Emission Test
Name Model No. Serial No. Manufacturer
Calibration
Date
Calibration
Cycle
EMI Test Receiver ESH3 860905/006 RS 2019.06.21 1Year
Spectrum Analyzer ESA-L1500A US37451154 HP 2019.06.21 1Year
PULSE LIMITER ESH3-Z2 100281 RS 2019.06.21 1Year
LISN ESH3-Z5 100294 RS 2019.06.21 1Year
LISN ESH3-Z5 100253 RS 2019.06.21 1Year
LISN NNB42 00012 SCHAFFNER 2019.01.08 1Year
2.2 Radiated Disturbance Test
Name Model No Serial No. Manufacturer
Calibration
Date
Calibration
Cycle
EMI Test Receiver ESVD 100008 RS 2019.06.21 1Year
Coaxial Switch MP59B M70585 ANRITSU N/A N/A
Spectrum Analyzer 8595E 3441A00893 HP 2019.06.21 1Year
ESD Simulator DITO 0404-24 EM TEST 2019.06.21 1Year
2.5 RF field Strength Susceptibility
Name Model No. Serial No. Manufacturer Calibration Calibration
Report No.: EMC1909073 Page 8 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Date Cycle
Signal Generator SMT03 100059 RS 2019.06.21 1Year
Power Meter NRVS --- RS 2019.06.21 1Year
Voltage Probe URV5-Z2 100012 RS 2019.06.21 1Year
Voltage Probe URV5-Z2 100013 RS 2019.06.21 1Year
Power Amplifier 150W1000 300999 AR 2019.06.21 1Year
Power Amplifier 25S1G4AM1 305993 AR 2019.06.21 1Year
Field Probe CBL6111C 2576 Holaday 2019.06.21 1Year
Bilog Antenna MCDC --- Chase 2019.06.21 1Year
2.6 Electrical Fast Transient/Burst (EFT/B) Immunity test
Name Model No. Serial No. Manufacturer
Calibration
Date
Calibration
Cycle
EFT Generator UCS 500 M4 0304-42 EM TEST 2019.06.21 1Year
Power Source MV2616 0104-14 EM TEST 2019.06.21 1Year
2.7 Surge Test
Name Model No. Serial No. Manufacturer Calibration Date
Calibration
Cycle
Ultra Compact
Simulator
UCS 500
M4 0304-42 EM TEST
2019.06.21
1Year
Power Source MV2616 0104-14 EM TEST 2019.06.21 1Year
2.8 Conducted Immunity Test
Name Model No. Serial No. Manufacturer
Calibration
Date
Calibration
Cycle
Continuous Wave
Simulator CWS 500C 0407-05 EM TEST
2019.06.21
1 Year
2.9 Power-frequency Magnetic Field
Name Model No. Serial No. Manufacturer
Calibration
Date
Calibration
Cycle
Continuous Wave
Simulator UCS 500 M4 0304-42
EM TEST
2019.06.21
1 Year
Power Source
Network MV 2616 0104-14
EM TEST
2019.06.21
1 Year
Report No.: EMC1909073 Page 9 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Current Transformer MC2630 -- EM TEST 2019.06.21 1 Year
Magnetic Coil MS100 0304-42 EM TEST 2019.06.21 1 Year
2.10 Voltage Dips/Interruption Immunity Test
Name Model No. Serial No. Manufacturer
Calibration
Date
Calibration
Cycle
Ultra Compact
Simulator UCS 500 M4 0304-42 EM TEST
2019.06.21
1Year
Power Source MV2616 0104-14 EM TEST 2019.06.21 1Year
Report No.: EMC1909073 Page 10 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
EN 55032: 2015 Electromagnetic compatibility of multimedia equipment - Emission
Requirements
EN61000-3-2:2014 Electromagnetic compatibility(EMC)- Part 3-2:Limits-Limits for harmonic
current emissions(equipment input current ≤16A per phase)
EN 61000-3-3:2013
Electromagnetic compatibility (EMC)- Part 3-3:Limits-Limitation of voltage
changes, Voltage fluctuations and flicker in public low-voltage supply systems.
For equipment with rated current ≤16A per phase and not subject to
conditional connection
EN 55035:2017 Electromagnetic compatibility of multimedia equipment - Immunity
requirements
EN 61000-4-2:2009 Electrostatic disc arge
EN 61000-4-3:2006 RF field strength suscepti ility
EN 61000-4-4:2012 Electrical Fast transients
EN 61000-4-5:2014 Surge
EN 61000-4-6:2009 Conducted susceptibility
EN 61000-4-8:2010 Power-frequency Magnetic Field
EN 61000-4-11:2004 Dips/Voltage Interruption Variation
3.3 Performance Criteria
Report No.: EMC1909073 Page 11 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
3.4 Test standards and Results Summary Tables
Test Condition Test Requirement Test Method Test Result
EMISSION Results Summary
Conducted Emission on AC Mains,
150kHz to 30MHz
EN 55032: 2015 EN 55032: 2015 Pass
Conducted Emission on at
telecommunication ports,
150kHz to 30MHz
EN 55032: 2015 EN 55032: 2015
N/A
Radiated Emissions,
30MHz to 6GHz
EN 55032: 2015 EN 55032: 2015 Pass
Harmonic Emissions on AC supply EN 61000-3-2: 2014 EN 61000-3-2: 2014 N/A
Voltage fluctuations on AC supply EN 61000-3-3:2013 EN 61000-3-3:2013 N/A
IMMUNITY Results Summary
Electrostatic Discharge EN 55035:2017 EN 61000-4-2: 2009 Pass
Continuous RF electromagnetic
field disturbances
EN 55035:2017 EN 61000-4-3: 2006 Pass
Continuous induced RF
disturbances
EN 55035:2017 EN 61000-4-6: 2009 Pass
Power frequency magnetic field EN 55035:2017 EN61000-4-8: 2010 N/A
Electrical fast transients/burst
(EFT/B)
EN 55035:2017 EN61000-4-4: 2012 Pass
Surges EN 55035:2017 EN 61000-4-5: 2014 Pass
Voltage dips and interruptions EN 55035:2017 EN 61000-4-11: 2004 Pass
Broadband impulsive conducted
disturbances
EN 55035:2017 EN 61000-4-6: 2009 N/A
Note: N/A-Not applicable
Report No.: EMC1909073 Page 12 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
4.0 Electromagnetic Interference Test results
4.1 Power line Conducted Emission Test
4.1.1 Schematics of the test
4.1.2 Test Method:
The test was performed in accordance with EN 55032: 2015
Block diagram of Test setup
4.1.3 Power line conducted Emission Limit
4.1.4 Test Results
Limits for Conducted Emission test, Please refer to limit line (Quasi-peak)and Average in the following
diagram labelled as (QP)&AV
Remark: Calculated measurement uncertainty=3.6dB
Report No.: EMC1909073 Page 13 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
A: Conducted Emission on Live Terminal (150kHz to 30MHz)
Report No.: EMC1909073 Page 14 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
B: Conducted Emission on Neutral Terminal (150kHz to 30MHz)
Report No.: EMC1909073 Page 15 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
4.2 Telecommunication ports Conducted Emission Test
4.2.1 Schematics of the test
4.2.2 Test Method:
The test was performed in accordance with EN 55032: 2015
Limits for Conducted Emission test, Please refer to limit line (Quasi-peak)and Average in the following
diagram labelled as (QP)&AV
Remark:
Calculated measurement uncertainty=1.9dB
Report No.: EMC1909073 Page 16 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
A: Conducted Emission on Telecommunication port (150kHz to 30MHz)
Report No.: EMC1909073 Page 17 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
B: Conducted Emission on Telecommunication port (150kHz to 30MHz)
Note: This test item is not applicable because there is no telecommunication port
Report No.: EMC1909073 Page 18 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
4.3 Radiated Disturbance Test
4.3.1 Schematics of the test
4.3.2 Test Method:
The test was performed in accordance with EN 55032: 2015
Block diagram of Test setup
4.3.3 Radiated Disturbance Test Limit
Frequency Range (MHz) Quasi-Peak limits (dBμV/m)
Class A Limits Class B Limits
30-230 50.00 40.00
230-1000 57.00 47.00
1000-3000 56(AV)/76(PK) 50(AV)/70(PK)
3000-6000 60(AV)/80(PK) 54(AV)/74(PK)
Note: The lower limit shall apply at the transition frequencies
4.3.4 Test result
Limits for Radiated Disturbance test, Please refer to limit line (Quasi-peak) in the following diagram
labelled as (QP)
Remark:
Calculated measurement uncertainty=4.7dB
Report No.: EMC1909073 Page 19 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
A: Radiated Disturbance (30MHz----1000MHz)
Project Number: CASE1 Test Time: 2019-09-20_16.03.14
EUT Name: Pen Holder B.V Test Engineer: KENT
Manufacturer: Mid Ocean Brands Test Standard: EN 55032
Report No.: EMC1909073 Page 20 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
B: Radiated Disturbance (30MHz----1000MHz)
Project Number: CASE1 Test Time: 2019-09-20_16.06.12
EUT Name: Pen Holder B.V Test Engineer: KENT
Manufacturer: Mid Ocean Brands Test Standard: EN 55032
Report No.: EMC1909073 Page 21 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
4.4 Harmonic Current Emission Test
4.4.1 Schematic of the test
4.4.2 Test Method:
The test was performed in accordance with EN 61000-3-2:2014
*: The Level of the product is : CLASS D
Block diagram of Test setup
4.4.3 Limits of Harmonic Current Emission For Class A
Report No.: EMC1909073 Page 22 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Report No.: EMC1909073 Page 23 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
4.5 Voltage Fluctuations &Flicker Test
4.5.1 Schematic of the test
4.5.2 Test Method:
The test was performed in accordance with EN 61000-3-3:2013
Block diagram of Test setup
4.5.3 Test Results
Result: N/A
Report No.: EMC1909073 Page 24 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
5.0 Immunity Test
5.1 Electrostatic Discharge
5.1.1 Schematic of the test
5.1.2 Test method
The test was performed in accordance with EN 61000-4-2: 2009
5.1.3 Test severity
±4kV for direct & in-direct Contact Discharge
±8kV for air Discharge
Performance Criterion Require: B (Please see following table)
5.1.4 Susceptibility performance Criteria and Severity level
Severity Level
Level Test Voltage Direct & in-direct contact
Discharge (kV)
Test Voltage Air
discharge(kV)
1 ±2kV ±2kV
2 ±4kV ±4kV
3 ±6kV ±8kV
4 ±8kV ±15kV
Report No.: EMC1909073 Page 25 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Report No.: EMC1909073 Page 26 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
5.2 RF field strength susceptibility (80MHz-1000MHz, 1800MHz, 2600MHz, 3500MHz, 5000MHz)
5.2.1 Schematics of the test
5.2.2 Test Method:
The test was performed in accordance with EN 61000-4-3:2006
Severity: Level 2 (3V/m)
Modulation: 80% AM
Performance Criterion Require: A (Please see following table)
Block diagram of Test setup
5.2.3 Susceptibility performance Criteria and severity Level
Susceptibility performance Criteria
Severity Level
Level Field Strength (V/m)
1 1
2 3
3 10
Report No.: EMC1909073 Page 27 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Please refer to the following table for individual results.
Frequency
(MHz)
Face Polarity Level
(V/m)
Dwell
Time(s)
Sweep
Rate (%)
Results
80-1000 0° Horizontal 3 1 1 Pass
80-1000 90° Horizontal 3 1 1 Pass
80-1000 180° Horizontal 3 1 1 Pass
80-1000 270° Horizontal 3 1 1 Pass
80-1000 0° Vertical 3 1 1 Pass
80-1000 90° Vertical 3 1 1 Pass
80-1000 180° Vertical 3 1 1 Pass
80-1000 270° Vertical 3 1 1 Pass
1800,
2600,
3500,
5000
0° Horizontal 3 1 1 Pass
90° Horizontal 3 1 1 Pass
180° Horizontal 3 1 1 Pass
270° Horizontal 3 1 1 Pass
1800,
2600,
3500,
5000
0° Vertical 3 1 1 Pass
90° Vertical 3 1 1 Pass
180° Vertical 3 1 1 Pass
270° Vertical 3 1 1 Pass
Report No.: EMC1909073 Page 28 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
5.3 Electrical Fast Transient/Burst (EFT/B) immunity test
5.3.1 Schematics of the test
5.3.2 Test Method
The test was performed in accordance with EN 61000-4-4:2012
Severity: Level 2 (1kV)
Performance Criterion Require: B (Please see following table)
Block diagram of Test setup
5.3.3 Susceptibility performance Criteria and Severity Level
Severity Level
Open Circuit output Test Voltage ±10%
Level On power Supply Lines On I/O (Input/output)
Signal data and control lines
1 0.5kV 0.5kV
2 1kV 1kV
3 2kV 2kV
4 4kV 4kV
X Special Special
Report No.: EMC1909073 Page 29 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Please refer to the following table for individual results.
Inject location: AC mains
Inject Line Voltage
kV
Inject
Times (s)
Method Results
L ±1 120 Direct Pass
N ±1 120 Direct Pass
L-N ±1 120 Direct Pass
Report No.: EMC1909073 Page 30 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
5.4 Surge test
5.4.1 Schematics of the test
5.4.2 Test Method:
The test was performed in accordance with EN 61000-4-5:2014
Severity: Level 2 (Line to Neutral at 1kV)
Performance Criterion Require: B (Please see following table)
Block diagram of Test setup
5.4.3 Susceptibility performance Criteria and Severity Level
Susceptibility performance Criteria
Report No.: EMC1909073 Page 31 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Please refer to the following table for individual results.
Test location:
Location Polarity Phase
Angle
No of
Pulse
Pulse
Voltage(kV)
Results
L-N
± 0 5 1.0 Pass
± 90 5 1.0 Pass
± 180 5 1.0 Pass
± 270 5 1.0 Pass
Report No.: EMC1909073 Page 32 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
5.5 Conducted Immunity test
5.5.1 Schematics of the test
5.5.2 Test Method
The test was performed in accordance with EN 61000-4-6:2009
Severity: Level 2 (3 V rms),0.15MHz—80MHz
Performance Criterion Require: A (Please see following table)
Block diagram of Test setup
5.5.3 Susceptibility performance Criteria and Severity Level
Susceptibility performance Criteria
Severity Level
Severity Level Voltage Level (e.m.f) V
1 1
2 3
3 10
* Special
Report No.: EMC1909073 Page 33 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Please refer to the following table for individual results.
Frequency
Range (MHz)
Injected
Posi ion
S rength Criterion Result
0.15 - 10 AC Line 3V (rms) A Pass
10 - 30 AC Line 3 to 1V (rms) A Pass
30-80 AC Line 1V (rms) A Pass
Note: the amplitude of a test level varies over a given frequency range, it changes linearly with
respect to the logarithm of the frequency
Report No.: EMC1909073 Page 34 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
5.6 Power-Frequency magnetic field test
5.6.1 Schematics of the test
5.6.2 Test Method
The test was performed in accordance with EN 61000-4-8:2010
Severity: Level 1 (1A/m),
Performance Criterion Require: A (Please see following table)
Block diagram of Test setup
5.6.3 Susceptibility performance Criteria and Severity Level
Susceptibility performance Criteria
Severity Level
Severity Level Magnetic Field Strength A/m
1 1
2 3
3 10
4 30
5 100
* Special
Report No.: EMC1909073 Page 35 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Please refer to the following table for individual results.
Test Level Testing Duration Coil Orientation Criterion Result
1A/m 5 Mins X A N/A
1A/m 5 Mins Y A N/A
1A/m 5 Mins Z A N/A
Report No.: EMC1909073 Page 36 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
5.7 Voltage Dips/Interruptions immunity test 5.7.1 Schematics of the test
5.7.2 Test Method:
The test was performed in accordance with EN 61000-4-11:2004
Performance Criterion Require: C&B (Please see following table)
Block diagram of Test setup
5.7.3 Susceptibility performance Criteria and Severity Level
Susceptibility performance Criteria
Report No.: EMC1909073 Page 37 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Please refer to the following table for individual results.
Voltage Dip:
Voltage Interceptions:
Test Level
% Ut
Reduction Duration
(periods)
Phase Angle Meet
Criterion
Result
0 100 0.5 0°- 360° B Pass
70 30 25 0°- 360° B Pass
Test Level
% Ut
Reduction Duration
(periods)
Phase Angle Meet
Criterion
Result
0 100 250 0°- 360° B Pass
Report No.: EMC1909073 Page 38 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
6.0 Product Labelling
6.1 CE Mark label specification
Text of the mark is black or white in color and is left justified. Labels are printed in indelible ink on
permanent adhesive backing and shall be affixed at a conspicuous location on the EUT or
silk-screened onto the EUT.
6.2 Mark Location: Rear enclosure
Report No.: EMC1909073 Page 39 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Appendix:
Conducted Emissions
Report No.: EMC1909073 Page 40 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Radiated Emissions
Report No.: EMC1909073 Page 41 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Photographs – EUT
Report No.: EMC1909073 Page 42 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Photographs – EUT
Report No.: EMC1909073 Page 43 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.
Photographs – EUT
Report No.: EMC1909073 Page 44 of 44Date: 2019-09-21
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate.