SMC Sectional Panel tanks By Systech Sector
Introduction to
Sarovar – Complete Assembly and Tested tankSarovar Complete Assembly and Tested tank
Actual installation at Pune
Systech Sector
4x4x2meter tank, 32KL
Introduction toComponents:
Roof & Base Panels1m x 1m
Side Panels1m x 1m1m x 1m
Manhole & Lid1m x 1m, Ø750mm
Ht. 100mm
Systech Sector
Ht. 100mm
Introduction toComponents:
Equal Angle
EPDM Sealant Inlet / Outlet Flange
and Nut Bolts
Tie RodsLadderRoof S pports
Systech Sector
LadderRoof Supports
Introduction toFeatures / Type of Tank RCC Tanks Steel Tanks
Rough internal surface
Hygiene
Smooth Surface –No formation and growth of algaeAirtight Manhole lid
Rough internal surface -Allow bacteria to nest & ProliferateNot airtight entry of dust in the tank
Highly prone to rust Contaminations.Not Airtight entry of dust in the tank
Dead load or Self weight Very Low Very High High
Base supportLight duty RCC Beams and Steel frame
Heavy Foundation RequiredHeavy Duty Skid Mounting
Mechanical Properties Excellent Good GoodMechanical Properties Excellent Good Good
Insulation Excellent Good Poor
Ease of Cleaning
Smooth surface allows easy cleaning as no
Incomplete & poor drainageResults in building up of residual water that harbors
Cleaning difficultPainting required to avoid rustingEase of Cleaning
deposition of algaeNo chemicals required
contaminantsHeavy cleaning chemicals required
avoid rustingCleaning process is unsafe
FlexibilityModular- Can be relocated and extended None NoneFlexibility relocated and extended easily
None None
AestheticsExcellentNo painting required
Aesthetically positive designs possible
Poor
Environmental Aspect Eco friendly Not an eco friendly conceptNot an eco friendly
Systech Sector
Environmental Aspect Eco friendly Not an eco friendly concepty
concept
Introduction to
Sr No Feature BenefitSr.No. Feature Benefit
1
Avg. Service life +/‐ 40yrsTested for extreme natural conditionsExcellent UV resistanceCan be assembled and dismantled easily
Extremely durableRe‐locatable
y2 Flexible rubber sealant with low thermal coefficient 100% Leak Proof
3Smooth surfaces reduces growth of algae and organismsExternal repairs ‐ easy by replacing damaged panel
Easy and Low maintanance
S th f t dh i f di t d l
4
Smooth surface ‐ prevents adhesion of dirt and algaeTotally opaque structure ‐ prevents bacterial growthNo metal in direct contact with water ‐ no rustingSpecially designed base panels ‐ COMPLETE drain out of waterFRP has low thermal coefficient ‐ Stable temperature
Retains the quality of Stored water
Panels manufactured at 1500C ‐ no chemicals to contaminate waterNo water proofing chemicals required
5Individually designed panels – With higher safety factor,Exceptional strength ‐ withstands all weather conditions
Extraordinary Mechanical and Physical Propertiesp g y p
6Available in various no. of capacities ‐1000L to 10Lac L+Extension of size ‐ possible and easyRelocation from site to site possible
Various sizes and adaptable structure
Systech Sector
Introduction to
Tanks’ condition after yearsTanks condition after years
Steel TanksRusting
RCC TanksAlgae formation
SMC Panel Tanks
Systech Sector
g
Introduction toApplications
• Over Head and on the ground water storage for drinking and daily use
• Fire fighting and rain water harvesting water storage tank
• Water treatment plantsp
• For STP plants
• For cold and hot water storage in industries
• For chiller HVAC water storage• For chiller, HVAC water storage
• For chemical storage* (* with special types of coatings)
Systech Sector
Introduction toCapacities
Sr. No.
Site dimensions (Meter)
Length BreadthHeight
1 2 3g
1 2 31 3 3 9 18 27
CA
2 4 4 16 32 483 7 7 49 98 147
PACI
KL
3 7 7 49 98 1474 10 10 100 200 3005 12 12 144 288 4326 15 10 150 300 450
TY
I
L7 15 15 225 450 6758 20 15 300 600 9009 20 20 400 800 1200 I
N10 25 20 500 1000 150011 25 25 625 1250 1875
Using site dimensions in meters capacities can be calculated in KL by simple formula - LxBxH
Systech Sector
Using site dimensions in meters, capacities can be calculated in KL by simple formula - LxBxH
Introduction toFAQs
Sr. No.
Question Explanation
1 What is Material used? SMC - Sheet Molding Compound
2 What is Manufacturing Process? Hot Press Compression Molding using P20 Metallic mold and India’s Largest capacity press of 2000TTemperature≈1600C
3 What type of foundation is required for tank assembly?
RCC foundation and Steel Girders
4 How is leakage addressed? Accurate panel dimensions – no gap at jointsEPDM rubber sealantSilicone sealant for additional safetyShorter pitch - 10 holes per flangeShorter pitch 10 holes per flange
Systech Sector
Introduction toFAQs
Sr. No. Question Explanation
5 Can Sarovar withstand Seismic forces and wind load?
Yes, Sarovar tanks are designed using advance technologies to withstand Seismic forces and wind l dloads
6 Is Sarovar flexible for capacities?
Yes, Re-locatableEasy extension of Capacities
7 What is expected life of Sarovar?
Minimum 40 Years
8 How Sarovar Tank is superior No Leakagethan RCC Tanks?
gNo direct contact with Building's RoofsLeast assembly timeLow Dead weightEconomical
Systech Sector
Also Available at -Delhi
Kolkata
Ahmadabad
PunePune
Mumbai
Hyderabad
B lBangalore
145, Nehru Nagar, Off Mumbai Pune Highway,Pimpri, Pune – 411 018Contact No – (020) 27425265 / 66Contact No. (020) 27425265 / 66Cell No. - +91 98220 50942
Website: www.mahindracomposites.comEmail id: info@mahindracomposites com