Top Banner
Revamping Existing Units to Increase Rates, Handle Lighter Feedstocks, and other Issues (Problems) Christopher Dean - HIGH Olefins Technology Services LLC May 2, 2019
38

Revamping Existing Units to Increase Rates, Handle Lighter ...

Nov 20, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Revamping Existing Units to Increase Rates, Handle Lighter ...

Revamping Existing Units

to Increase Rates, Handle

Lighter Feedstocks, and

other Issues (Problems)

Christopher Dean -

HIGH Olefins Technology Services LLC

May 2, 2019

Page 2: Revamping Existing Units to Increase Rates, Handle Lighter ...

2

Need for Revamps?

To Make Your FCC Facility*

More Reliable - More Flexible

• Operational & Maintenance Reliabilities

• Feedstock & Product Flexibilities

• Maximize Profits!!!

Page 3: Revamping Existing Units to Increase Rates, Handle Lighter ...

3

Purpose (Objective)

To Present and Briefly discuss:

• What to Look for in Your FCC Unit /Facility ?

• What Can We* Do ?

* We Refiner…

Page 4: Revamping Existing Units to Increase Rates, Handle Lighter ...

4

Need for Revamps? When & Why ?

• When --- Maintenance / Repairs – (Reliability)

• Shutdowns & Turnarounds

• Scheduled & Unscheduled

• Why? ( Flexibility)

• Meet New Specifications - Products,

Environmental, Others ?

• Different Feedstocks -Different Products

• Different Operating Mode

• Distillate Mode + Propylene

• Gasoline Mode + Petrochemical Feedstocks

Page 5: Revamping Existing Units to Increase Rates, Handle Lighter ...

5

Need for Revamps? Why

• Different Feedstocks

• More Severe HDT

• Less Heavy Crudes /

• Less Resid or (More Resid Heavy Crudes?? )

• Lighter Feeds –

• Tight Oil

• Condensates

• Naphtha (paraffinic)

• Others??

Page 6: Revamping Existing Units to Increase Rates, Handle Lighter ...

6

Need for Revamps?

• Change Current Operating Modes &

Feedstocks

To:

• Gasoline + Alkylate (G&A) - More C3=

• More Petrochemicals – Olefins & Aromatics

Alkylate- Olefins & Aromatics

( 30 ppm S Gasoline - May 1st Refcom Gal 19 Pres.)

• Different Mode – More Distillate + C3=

Page 7: Revamping Existing Units to Increase Rates, Handle Lighter ...

7

Existing Unit Limits ? Pg. 1

Do you know… (Take a GOOD LOOK)

Feedstocks & Products Flexibilities

• Longer Term Supply

• What Crude / Feedstocks Available?

• What Potential FS from other process units ?

Cokers, Visbreakers, Hydrotreaters

/Hydrocrackers, Lube Plant, etc.

• Potential Feedstocks from the surrounding area?

Chemical Plants, Lube Plants, Power Plants

(Coal), etc.

Page 8: Revamping Existing Units to Increase Rates, Handle Lighter ...

8

Existing Unit Limits ? Pg. 2

Do you know… (Take a GOOD LOOK)

Converter Section Reactor / Regenerator

• Max. / Min Fresh/ Recycle Feedrates

• What Feedstock Qualities & Variability

• What Product Slate / Slates ?

Page 9: Revamping Existing Units to Increase Rates, Handle Lighter ...

9

Existing Unit Limits ? Pg. 3

Do you know… (Take a GOOD LOOK)

• Air Blower Rates / Coke Burning Rates

• Min / Max -

To Increase:

• Reducing Delta P

• O2 Enrichment

• Remove/Replace Orifice Chamber With

Valves(?)

Page 10: Revamping Existing Units to Increase Rates, Handle Lighter ...

10

Existing Unit Limits ? Pg. 4

Do you know… (Take a GOOD LOOK)

• Catalyst Circulation Rates – Limitations / Increase?

• Standpipe Delta P’s

• Increase Bed Levels

• Increase/Improve Fluidization

• Aeration Taps

• Coke Burning Rates (Regen Locations / 2 Stages)

• Stripping / Dispersion Steam Rates

• Lift Gas Rates - Riser/ Transfer Lines Standpipe

( Even if Possible?)

Page 11: Revamping Existing Units to Increase Rates, Handle Lighter ...

11

Existing Unit Limits ? Pg 5

Do you know… (Take a GOOD LOOK)

• Coke Burning …..

• Reactor Cat Stripper

• How Effective…..

• Steam Quantity Entrained to Regen

• Light Feedstocks …… ?

• Cool Regenerator

• Cut Stripping Steam

• or

Page 12: Revamping Existing Units to Increase Rates, Handle Lighter ...

12

Stripper

Dispersed “Lean Oil” to Rx Stripper for

carry over into the regenerator

• Example

Page 13: Revamping Existing Units to Increase Rates, Handle Lighter ...

13

Lean Oil Locations

Page 14: Revamping Existing Units to Increase Rates, Handle Lighter ...

14

Existing Unit Limits ?

Do you know… (Take a GOOD LOOK)

Main Column … (Heat Removal)

• Reduce Delta P - (packing)

• Improve Fractionation

• Install Product Draws LCG / HCG

• LCO /HCO Product Draws

• Install a Second Fractionation Column

• Parallel Column

• Preflash Column

• New Top Section – in Series

Page 15: Revamping Existing Units to Increase Rates, Handle Lighter ...

15

Existing Unit Limits ?

Do you know… (Take a GOOD LOOK)

Main Column … (Heat Removal)

• Bottoms / Slurry

• Recycle for Heat Balance / Increase Coke Make

• PREVENT TOWER BOTTOMS COKING

• Slurry Product for Cokers!

Page 16: Revamping Existing Units to Increase Rates, Handle Lighter ...

16

Existing Unit Limits ?

Do you know… (Take a GOOD LOOK)

Gas Concentration

• Wet Gas Compressor –

• Absorbers / Strippers

• Treating (Various)

Product Recovery

• Splitters –

▪ Naphtha/Gasoline

▪ Propylene / Propane

Page 17: Revamping Existing Units to Increase Rates, Handle Lighter ...

17

Existing Unit Limits ?

Do you know… (Take a GOOD LOOK)

Downstream Units

Alkylate Feedstocks --- Butylenes

/Pentenes ?

FCC Gasoline Hydrotreaters – ( Invista – Refcom Gal 2019 )

• Solvent Extraction Technology – Sweetening, &

Aromatics

ANYTHING ELSE ???

Page 18: Revamping Existing Units to Increase Rates, Handle Lighter ...

18

Need for Revamps?

More Reliable - More Flexible

• Operational & Maintenance Reliabilities

• Feedstocks & Products Flexibilities

Maximum Unit Flexibility

• Install / Utilize 2nd Cracking Reaction Zone

Page 19: Revamping Existing Units to Increase Rates, Handle Lighter ...

19

Need for Revamps?

Maximum Unit Flexibility

• Install / Utilize 2nd Cracking Reaction Zone

• Separate (2nd ) Reactor Vessel

& Fractionation Sections

Page 20: Revamping Existing Units to Increase Rates, Handle Lighter ...

20

20

Fresh Feed Feed or Recycle Injection

Primary Feed

Riser

Second Riser For

Light Feed or Naphtha

Recycle

KBR MAXOFIN Process

Page 21: Revamping Existing Units to Increase Rates, Handle Lighter ...

21

590 Deg C = 1100 Deg F

Potential 2nd Rx

Vessel

Page 22: Revamping Existing Units to Increase Rates, Handle Lighter ...

22

22

UOP PetroFCC Process

Page 23: Revamping Existing Units to Increase Rates, Handle Lighter ...

23

RxCat Technology Process Design

• Increases

Regenerator

Temperature

• Mixes Spent &

Regen in Mixing

Chamber at base of

Riser

Page 24: Revamping Existing Units to Increase Rates, Handle Lighter ...

24

Need for Revamps?

Maximum Unit Flexibility

• Install / Utilize 2nd Cracking Reaction Zone

Page 25: Revamping Existing Units to Increase Rates, Handle Lighter ...

25

HS-FCC Key Components

Feed injection

Regenerator

Stripper using

structured packing

Catalyst / product

separator

Downflow

reactor

Courtesy Axens/S&WCourtesy Axens/TechnipS&W

Page 26: Revamping Existing Units to Increase Rates, Handle Lighter ...

26

Regenerator

Existing RFCC

Reactor Riser

Reactor - Stripper

Vessel

Downer Reactor

Stripper Vessel

Retrofit

Retrofit To Axens/Shaw’s R2R FCC Unit

Page 27: Revamping Existing Units to Increase Rates, Handle Lighter ...

27HS-FCC RETROFIT EXAMPLE

Page 28: Revamping Existing Units to Increase Rates, Handle Lighter ...

28

Block Flow Diagram

Fract. Plant

& Gas Recovery

Quench

Tower

&

Gas Recovery

Refinery Off

Gas

Purification

(ROG)

C3 C4

Purification

& Separation

Main Column &

Unsaturate Gas

Plant ; Treating to

produce Fuel

Grade Products

Polymer Grade

Propylene & Propane

to Steam Cracker

Polymer Grade

Ethylene & Ethane

to Steam Cracker

Fuel Grade Products

to Sales

28

Page 29: Revamping Existing Units to Increase Rates, Handle Lighter ...

29

Need for Revamps?

Maximum Unit Flexibility

• Install / Utilize 2nd Cracking Reaction Zone

• Separate (2nd ) Reactor Vessel

& Fractionation Sections

• 2 Rx Zone in a Single Riser

Page 30: Revamping Existing Units to Increase Rates, Handle Lighter ...

30

30

AIR

Feed Nozzles

PRODUCT VAPORS

FLUE GAS

REGENERATOR

REACTOR

RISER

REACTOR

MTC Nozzles

Typical Location

MTC Nozzle

JR Location

MTC NOZZLE ELEVATION LOCATIONS

REACTION SECTION

Page 31: Revamping Existing Units to Increase Rates, Handle Lighter ...

31

OIL

STEAM

STEAM

Zone 1

Zone 2

Feed Injection

Nozzles

RegeneratedCatalyst

Mix ZoneTemperature

Recycle QuenchInjection

MTC Nozzles

Cfd/MTC-SK1

MIX TEMPERATURE CONTROL (MTC)

Page 32: Revamping Existing Units to Increase Rates, Handle Lighter ...

32

RISER TEMPERATURE PROFILE

500

520

540

560

580

600

620

RISER HEIGHT

Ris

er Tem

perature (°C

)

Without MTC

With MTC

520 °

510 °

Feed

Injection MTC

Injection

Mix Zone

Zone 1 Zone 2

Page 33: Revamping Existing Units to Increase Rates, Handle Lighter ...

33

Need for Revamps?

Maximum Unit Flexibility

• Install / Utilize 2nd Cracking Reaction Zone

• Separate (2nd ) Reactor Vessel

& Fractionation Sections

• PRODUCE PETROCHEMICALS from LIGHT

FEEDSTOCKS - Naphtha / Paraffinic

(LSR/ Condensates, Others)

Page 34: Revamping Existing Units to Increase Rates, Handle Lighter ...

34

Petrochemicals Opportunities

Main Building Blocks

• Olefins - Two Main Blocks

• Ethylene

• Propylene

• Butylenes

• Aromatics

• Benzene

• Paraxylene (other xylenes too)

* High Olefins - FCC (HOFCC) produces C3= and

byproducts of other light olefins and aromatics

Secondary Source Produced by FCC’s

Produced by Steam Cracking

Ethane & Liquid Feeds

Naphtha Reformers

Co-monomer & ALKY Feedstock

Page 35: Revamping Existing Units to Increase Rates, Handle Lighter ...

35

Advanced Catalytic Olefins (ACO)Process

Page 36: Revamping Existing Units to Increase Rates, Handle Lighter ...

36

HS-FCC Naphtha Process

• Retrofit Type to

existing FCCU

• Standalone Unit

Page 37: Revamping Existing Units to Increase Rates, Handle Lighter ...

37

Naphtha Cracking Fluid Processes

ACO Commercial

Demonstration Unit

Ulsan, South Korea

* HS-FCC Semi-Commercial

Unit Mizushima, Japan

Downer Technology

** Downer Rx. Potential Use

Page 38: Revamping Existing Units to Increase Rates, Handle Lighter ...

38

The End

Questions - Comments ???

Follow-up Discussions?

THANK YOU

Christopher Dean -HIGH Olefins Technology Services LLC