Top Banner
3 Resource Access Measurement DN9813745 Issue 10-0 en 18/03/2008 # Nokia Siemens Networks 1 (81) BSC3153 Nokia GSM/EDGE BSS, Rel. BSS13, BSC and TCSM, Rel. S13, Product Documentation, v.1
81
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • 3 Resource Access Measurement

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 1 (81)

    BSC3153Nokia GSM/EDGE BSS, Rel. BSS13, BSC andTCSM, Rel. S13, Product Documentation, v.1

  • The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This documentation is intended for theuse of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted inany form or means without the prior written permission of Nokia Siemens Networks. Thedocumentation has been prepared to be used by professional and properly trained personnel,and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomescustomer comments as part of the process of continuous development and improvement of thedocumentation.

    The information or statements given in this documentation concerning the suitability, capacity, orperformance of the mentioned hardware or software products are given as is and all liabilityarising in connection with such hardware or software products shall be defined conclusively andfinally in a separate agreement between Nokia Siemens Networks and the customer. However,Nokia Siemens Networks has made all reasonable efforts to ensure that the instructionscontained in the document are adequate and free of material errors and omissions. NokiaSiemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues whichmay not be covered by the document.

    Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NOEVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THISDOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL,DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUTNOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESSOPPORTUNITY OR DATA, THAT MAYARISE FROM THE USE OF THIS DOCUMENT OR THEINFORMATION IN IT.

    This documentation and the product it describes are considered protected by copyrights andother intellectual property rights according to the applicable laws.

    The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark ofNokia Corporation. Siemens is a registered trademark of Siemens AG.

    Other product names mentioned in this document may be trademarks of their respective owners,and they are mentioned for identification purposes only.

    Copyright Nokia Siemens Networks 2008. All rights reserved.

    2 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Contents

    Contents 3

    List of tables 5

    List of figures 6

    Summary of changes 7

    1 3 Resource Access Measurement 9

    2 Counters of Resource Access Measurement 132.1 003000 / PAGING MESSAGES SENT TO BTS 132.2 003001 / IMMEDIATE ASSIGNMENT MESSAGES SENT TO BTS 132.3 003002 / IMMEDIATE ASSIGNMENT REJECT MESSAGES SENT TO

    BTS 142.4 003003 / SMS BC REQUEST MESSAGES SENT TO BTS 152.5 003004 / CHANNEL REQUEST MESSAGES RECEIVED FROM BTS 152.6 003005 / DELETE IND MESSAGES RECEIVED FROM BTS 162.7 003006 / AVE RACH SLOT COUNT 172.8 003007 / RES ACC DENOMINATOR 1 172.9 003008 / AVE PCH LOAD ON CCCH 182.10 003009 / RES ACC DENOMINATOR 2 192.11 003010 / PEAK RACH LOAD ON CCCH 192.12 003011 / PEAK PCH LOAD ON CCCH 202.13 003012 / SUCCESS SEIZURE FOR MOBILE TERM CALL 212.14 003013 / SUCCESS SEIZURE FOR MOBILE ORIG CALL 212.15 003014 / AVE RACH BUSY COUNT 222.16 003015 / RES ACC DENOMINATOR 3 232.17 003016 / AVE RACH ACCESS COUNT 232.18 003017 / RES ACC DENOMINATOR 4 242.19 003018 / MIN PAGING BUF 252.20 003019 / SDCCH LOC UPD 252.21 003020 / SDCCH CALL RE EST 262.22 003021 / SDCCH EMERG CALL 272.23 003022 / TCH EMERG CALL 272.24 003023 / TCH MTC 282.25 003024 / TCH MOC 282.26 003025 / TCH CALL RE EST 292.27 003026 / SUCC TCH SMS EST 302.28 003027 / UNSUCC TCH SMS EST 302.29 003028 / SUCC SDCCH SMS EST 312.30 003029 / UNSUCC SDCCH SMS EST 322.31 003030 / GHOST CCCH RES 322.32 003031 / REJ SEIZ ATT DUE DIST 332.33 003032 / TRX IN EXT AREA 342.34 003033 / IMSI DETACH SDCCH 342.35 003034 / IMSI DETACH TCH 352.36 003035 / MAX PAGING BUFFER CAPA 36

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 3 (81)

    Contents

  • 2.37 003036 / AVE PAGING BUFFER CAPA 362.38 003037 / RES ACC DENOMINATOR 5 372.39 003038 / DELETE PAGING COMMAND 382.40 003039 / BCSU OVERLOAD LOWER LIMIT 392.41 003040 / BCSU OVERLOAD UPPER LIMIT 392.42 003041 / BCSU OVERLOAD DELETED RACH 402.43 003042 / TRX DIAGNOSTICS 402.44 003043 / TRX DIAGNOSTICS FAULT 412.45 003044 / SUCC SEIZ SUPPLEM SERV 422.46 003045 / TCH SUPPLEM SERV 422.47 003046 / AVE PCH GB LOAD ON CCCH 432.48 003047 / RES ACC DENOMINATOR 6 432.49 003048 / AVE PAGING GB BUF 442.50 003049 / RES ACC DENOMINATOR 7 452.51 003050 / MAX PAGING GB BUF 462.52 003051 / AVE PAGING LOAD AIR 462.53 003052 / RES ACC DENOMINATOR 8 472.54 003053 / AVE DRX AGCH LOAD AIR 482.55 003054 / RES ACC DENOMINATOR 9 492.56 003055 / AVE NON DRX AGCH LOAD AIR 492.57 003056 / RES ACC DENOMINATOR 10 502.58 003057 / PS PAGING MSG SENT 512.59 003058 / CS PAGING MSG SENT 522.60 003059 / CALL ASSIGN AFTER SMS 522.61 003060 / SPARE003060 532.62 003061 / SPARE003061 532.63 003062 / SPARE003062 542.64 003063 / SPARE003063 542.65 003064 / SUCC MO SMS SDCCH 552.66 003065 / UNSUCC MO SMS SDCCH 56

    3 Signalling charts of Resource Access Measurement 57

    4 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • List of tables

    Table 1. Measurement description of Resource Access Measurement 9

    Table 2. Counters of Resource Access Measurement 9

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 5 (81)

    List of tables

  • List of figures

    Figure 1. Basic call without counters. 58

    Figure 2. Basic call without counters (cont.). 59Figure 3. Basic call with counters. 60

    Figure 4. FACCH call setup due to SDCCH congestion. 61

    Figure 5. Ghost reservation. 62

    Figure 6. Busy AGCH-channel. 63

    Figure 7. Unsuccessful channel request. 64

    Figure 8. SMS broadcast. 64

    Figure 9. Mobile originating SMS on a TCH. 65

    Figure 10. Mobile terminating SMS on a TCH. 66

    Figure 11. Mobile originating SMS on FACCH. 67

    Figure 12. Mobile terminating SMS on FACCH. 68

    Figure 13. Mobile originating SMS on an SDCCH. 69

    Figure 14. Mobile terminating SMS on an SDCCH. 70

    Figure 15. Mobile originating unsuccessful SMS on a TCH. 71

    Figure 16. Mobile terminating unsuccessful SMS on a TCH. 72

    Figure 17. Mobile originating unsuccessful SMS on FACCH. 73

    Figure 18. Mobile terminating unsuccessful SMS on FACCH. 74

    Figure 19. Mobile originating unsuccessful SMS on an SDCCH. 75

    Figure 20. Mobile terminating unsuccessful SMS on an SDCCH. 76

    Figure 21. CCCH load indication. 77

    Figure 22. CCCH Load Indication if GPRS is activated in BTS and other conditionsare valid. 79

    Figure 23. Unsuccessful channel requests because of BCSU overload. 80

    Figure 24. PS Paging in GPRS 80

    Figure 25. CS Paging in GPRS. 81

    6 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Summary of changes

    Changes between document issues are cumulative. Therefore, the latestdocument issue contains all changes made to previous issues.

    Changes made between issues 10-0 and 9-2

    Counter table format changed.

    Changes made between issues 92 and 91

    The Description and Updated fields of counters 003036 and 003037modified.

    Changes made between issues 91 and 9

    Editorial changes.

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 7 (81)

    Summary of changes

  • 8 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • 1 3 Resource Access MeasurementResource Access Measurement registers information on all commoncontrol channels (CCCH) of the base station controller. The recorded itemsof data comprise the number of messages sent to the Abis interface. Themessages are sorted according to message type, average load on controlchannels, and the number of traffic channel seizures for mobile originating(MOC) and terminating calls (MTC). Signalling charts are drawn with theaccuracy of message interface.

    Measurement description

    Table 1. Measurement description of Resource Access Measurement

    Measurement

    Measurement ID

    Measurement abbreviation

    Resource Access Measurement

    3

    CCCH_ACC

    Product BSC

    Product software release S1

    Target name BTS+TRX

    Measurement counters

    Table 2. Counters of Resource Access Measurement

    Counter Counter number

    Paging messages sent to BTS 003000

    Immediate assignment messages sent to BTS 003001

    Immediate assignment reject messages sent to BTS 003002SMS CB request messages sent to BTS 003003

    Channel request messages received from BTS 003004

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 9 (81)

    3 Resource Access Measurement

  • Table 2. Counters of Resource Access Measurement (cont.)

    Counter Counter number

    Delete indication messages received from BTS 003005

    Average RACH slot counter 003006

    Resource access denominator 1 003007

    Average PCH load on CCCH 003008

    Resource access denominator 2 003009

    Peak RACH load on CCCH 003010

    Peak PCH load on CCCH 003011

    Success seizure for MTC 003012

    Success seizure for MOC 003013

    Average RACH busy counter 003014

    Resource access denominator 3 003015

    Average RACH access counter 003016

    Resource access denominator 4 003017

    Minimum paging buffer 003018

    SDCCH location update 003019

    SDCCH call re-establishment 003020

    SDCCH emergency call 003021

    TCH emergency call 003022

    TCH MTC 003023

    TCH MOC 003024

    TCH call re-establishment 003025

    Success TCH SMS establishment 003026

    Unsuccessful TCH SMS establishment 003027

    Success SDCCH SMS establishment 003028

    Unsuccessful SDCCH SMS establishment 003029

    Ghost CCCH reservation 003030

    Rejected seizure attempt due to distance 003031TRX in extended area 003032

    IMSI detach SDCCH 003033

    IMSI detach TCH 003034

    Maximum paging buffer capacity 003035

    Average paging buffer capacity 003036

    10 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Table 2. Counters of Resource Access Measurement (cont.)

    Counter Counter number

    Resource access denominator 5 003037

    Delete paging command 003038

    BCSU overload lower limit 003039

    BCSU overload upper limit 003040

    BCSU overload deleted RACH 003041

    TRX diagnostics 003042

    TRX diagnostics fault 003043

    Successful seizures of SDCCHs 003044

    Successful seizures of TCHs 003045

    Paging load paging buffer space on Gb-interference 003046

    Resource access denominator 6 003047

    Average buffer occupancy percentage 003048

    Resource access denominator 7 003049

    Maximum buffer occupancy percentage 003050

    Average CCCH load radio block occupancy paging 003051

    Resource access denominator 8 003052

    Average DRX AGCH 003053

    Resource access denominator 9 003054

    Average NON-DRX AGCH 003055

    Resource access denominator 10 003056

    PS paging command 003057

    CS paging command 003058

    Call assign after SMS 003059

    Spare 003060

    Spare 003061

    Spare 003062

    Spare 003063

    Successful mobile-originated SMS establishment onan SDCCH

    003064

    Unsuccessful mobile-originated SMS establishmenton an SDCCH

    003065

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 11 (81)

    3 Resource Access Measurement

  • Related topics

    . Counters of Resource Access Measurement

    . Signalling charts of Resource Access Measurement

    . BSC Statistics Administration

    . Activating and Testing BSS6037: Improved Solution for ExtendedCell

    . BSC Measurement Counters Displaying Program (FOXMEA)

    . Performance Measurements

    . EDGE System Feature Description

    . Extended Cell Range

    12 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • 2 Counters of Resource AccessMeasurement

    2.1 003000 / PAGING MESSAGES SENT TO BTS

    Counter ID: 003000 Network element name: PAGING MESSAGES SENT TOBTS

    Version: 2.1 NetAct name: PAGING_MSG_SENT

    Description: Number of PAGING_COMMAND messages sent to the BTS.

    Updated: When a PAGING_COMMAND message is sent to the BTS.

    See figure Basic call with counters.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    2.2 003001 / IMMEDIATE ASSIGNMENT MESSAGESSENT TO BTS

    Counter ID: 003001 Network element name: IMMEDIATE ASSIGNMENTMESSAGES SENT TO BTS

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 13 (81)

    Counters of Resource Access Measurement

  • Version: 2.1 NetAct name: IMM_ASSGN_SENT

    Description: Number of IMMEDIATE_ASSIGN_COMMAND messages sent to the BTS.

    Updated: When an IMMEDIATE_ASSIGN_COMMAND message is sent to the BTS.

    See figures:Basic call with countersBusy AGCH Channel

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    2.3 003002 / IMMEDIATE ASSIGNMENT REJECTMESSAGES SENT TO BTS

    Counter ID: 003002 Network element name: IMMEDIATE ASSIGNMENTREJECT MESSAGES SENT TO BTS

    Version: 2.1 NetAct name: IMM_ASSGN_REJ

    Description: Number of IMMEDIATE_ASSIGNMENT_REJECT messages sent to the BTS.

    Updated: This counter is updated when an IMMEDIATE_ASSIGNMENT_REJECT message is packedand sent to the BTS. The message can include one to four immediate assignment rejects.

    The IMMEDIATE_ASSIGNMENT_REJECT message is sent to MS in the following cases:No free SDCCH.Abis interface process has no internal resources to handle the request.

    See figure Unsuccessful channel request

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):

    14 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • 3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release: S6

    2.4 003003 / SMS BC REQUEST MESSAGES SENT TOBTS

    Counter ID: 003003 Network element name: SMS BC REQUEST MESSAGESSENT TO BTS

    Version: 2.1 NetAct name: SMS_BC_REQ_SENTDescription: Number of SMS_BROADCAST_REQUEST messages sent to the BTS.Updated: When all 4 SMS_BROADCAST_REQUEST messages are sent to the BTS.

    See figure SMS broadcast

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    2.5 003004 / CHANNEL REQUEST MESSAGESRECEIVED FROM BTS

    Counter ID: 003004 Network element name: CHANNEL REQUEST MESSAGESRECEIVED FROM BTS

    Version: 2.1 NetAct name: CH_REQ_MSG_RECDescription: Number of CHANNEL_REQUIRED messages received from the BTS.

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 15 (81)

    Counters of Resource Access Measurement

  • Updated: When a CHANNEL_REQUIRED message is received from the BTS. These requests arerelated to CSW channels. PSW channel requests have their own counter 072082.

    See figures:Basic call with countersGhost reservationBusy AGCH channelUnsuccesful channel requestUnsuccesful channel requests due to BCSU overload

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    2.6 003005 / DELETE IND MESSAGES RECEIVEDFROM BTS

    Counter ID: 003005 Network element name: DELETE IND MESSAGESRECEIVED FROM BTS

    Version: 2.1 NetAct name: DEL_IND_MSG_REC

    Description: Number of DELETE_INDICATION messages received from the BTS.

    Updated: When a DELETE_INDICATION message is received from the BTS.

    See figure Busy AGCH Channel

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    16 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • 2.7 003006 / AVE RACH SLOT COUNT

    Counter ID: 003006 Network element name: AVE RACH SLOT COUNT

    Version: 2.1 NetAct name: AVE_RACH_SLOT

    Description: Average number of the RACH slots on a CCCH.

    Counter 003007 is updated along with this counter.

    Updated: When the value of the RACH load is received in a CCCH_LOAD_INDICATION messagefrom the BTS during a measurement period. The new value of the RACH load is added to theprevious value, and the number of events is increased by one.

    See figure CCCH load indication.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003007: RES ACC DENOMINATOR 1

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    2.8 003007 / RES ACC DENOMINATOR 1

    Counter ID: 003007 Network element name: RES ACC DENOMINATOR 1

    Version: 2.1 NetAct name: RES_ACC_DENOM1

    Description: Denominator of the average RACH slot number (always > 0).

    Counter 003006 is updated along with this counter.

    Updated: See figure CCCH load indication

    Logical type: Sum Trigger type: Event Sampling interval:

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 17 (81)

    Counters of Resource Access Measurement

  • Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003006: AVE RACH SLOT COUNT

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    2.9 003008 / AVE PCH LOAD ON CCCH

    Counter ID: 003008 Network element name: AVE PCH LOAD ON CCCH

    Version: 2.1 NetAct name: AVE_PCH_LOAD

    Description: When divided by the value of counter 003009, this counter tells the Average PCH load ona CCCH. It indicates the remaining space for Paging Commands associated with this CCCH timeslot,given as the number of additional Paging Commands that it is possible to store. The smaller thevalue, the greater the load on the PCH.

    This counter is updated along with counter 003009.

    Updated: Cumulatively during the measurement period every time when the latest value of the PCHload is received in a CCCH_LOAD_INDICATION message from the BTS.

    See figure CCCH load indication.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003009: RES ACC DENOMINATOR 2

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    18 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • 2.10 003009 / RES ACC DENOMINATOR 2

    Counter ID: 003009 Network element name: RES ACC DENOMINATOR 2

    Version: 2.1 NetAct name: RES_ACC_DENOM2

    Description: Denominator of the average PCH load on CCCH (always > 0).

    Counter 003008 is updated along with this counter.

    Updated: See figure CCCH load indication.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003008: AVE PCH LOAD ON CCCH

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    2.11 003010 / PEAK RACH LOAD ON CCCH

    Counter ID: 003010 Network element name: PEAK RACH LOAD ON CCCH

    Version: 2.1 NetAct name: PEAK_RACH_LOAD

    Description: Peak value of the number of busy RACHs on a CCCH.

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 19 (81)

    Counters of Resource Access Measurement

  • Updated: When the value of the RACH load received in a CCCH_LOAD_INDICATION messageexceeds the previous value of the RACH load during the measurement period.

    NOTE! This RACH counter is triggered when the RX Level is above -100dBm. Other detectionmethods (like CRC or S/N) are not applied. This means that high load on RACH may occure evenwithout a significant number of CHANNEL_REQUIRED messages. For example, RACHs from differentMSs can clash and cause a high signal level, but the decoding does not find any detectable RACH.The interference causes lots of bursts that trigger the counter, but these bursts are then filtered out inthe detection.

    See figure CCCH load indication.

    Logical type: Max Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    2.12 003011 / PEAK PCH LOAD ON CCCH

    Counter ID: 003011 Network element name: PEAK PCH LOAD ON CCCH

    Version: 2.0 NetAct name: PEAK_PCH_LOAD

    Description: This counter is NOT relevant.

    This counter has been replaced by counter 003018 MIN PAGING BUF.

    Updated:

    Logical type: Trigger type: Sampling interval:

    Unit: Range: Example values:

    Dependencies with other counters:

    003018: MIN PAGING BUF

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    20 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    2.13 003012 / SUCCESS SEIZURE FOR MOBILE TERMCALL

    Counter ID: 003012 Network element name: SUCCESS SEIZURE FOR MOBILETERM CALL

    Version: 2.1 NetAct name: SUCC_SEIZ_TERM

    Description: Number of successful seizures of SDCCHs for an MTC.

    Updated: When an ESTABLISH_INDICATION message with paging response is received on SDCCHfrom the BTS.

    See figure Basic call with counters.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    2.14 003013 / SUCCESS SEIZURE FOR MOBILE ORIGCALL

    Counter ID: 003013 Network element name: SUCCESS SEIZURE FOR MOBILEORIG CALL

    Version: 2.1 NetAct name: SUCC_SEIZ_ORIG

    Description: Number of successful seizures for SDCCH for an MOC.

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 21 (81)

    Counters of Resource Access Measurement

  • Updated: When an ESTABLISH_INDICATION message with CM service request is received onSDCCH from the BTS.

    Note that this counter is updated also in case of an SMS or Supplementary Service Requests.

    See figure Basic call with counters.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    2.15 003014 / AVE RACH BUSY COUNT

    Counter ID: 003014 Network element name: AVE RACH BUSY COUNT

    Version: 2.1 NetAct name: AVE_RACH_BUSY

    Description: Average number of busy RACHs on a CCCH.

    Counter 003015 is updated along with this counter.

    Updated: When the value of the RACH load is received in a CCCH_LOAD_INDICATION messagefrom the BTS during a measurement period. The number of busy RACHs is added to the previousvalue and the number of the events is increased by one.

    NOTE! This RACH counter is triggered when the RX Level is above -100dBm. Other detectionmethods (like CRC or S/N) are not applied. This means that high load on RACH may occure evenwithout a significant number of CHANNEL_REQUIRED messages. For example, RACHs from differentMSs can clash and cause a high signal level, but the decoding does not find any detectable RACH.The interference causes lots of bursts that trigger the counter, but these bursts are then filtered out inthe detection.

    See figure CCCH load indication.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003015: RES ACC DENOMINATOR 3

    22 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    2.16 003015 / RES ACC DENOMINATOR 3

    Counter ID: 003015 Network element name: RES ACC DENOMINATOR 3

    Version: 2.1 NetAct name: RES_ACC_DENOM3

    Description: Denominator of the average number of busy RACHs (always > 0).

    Counter 003014 is updated along with this counter.

    Updated: See figure CCCH load indication.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003014: AVE RACH BUSY COUNT

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    2.17 003016 / AVE RACH ACCESS COUNT

    Counter ID: 003016 Network element name: AVE RACH ACCESS COUNT

    Version: 2.1 NetAct name: AVE_RACH_ACCESS

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 23 (81)

    Counters of Resource Access Measurement

  • Description: Number of average RACH accesses on a CCCH.

    Counter 003017 is updated along with this counter.

    Updated: When the value of the RACH load is received in a CCCH_LOAD_INDICATION messagefrom the BTS during a measurement period. The number of RACH accesses is added to the previousvalue and the number of events is increased by one.

    NOTE! This counter is updated by RACH bursts above the -100 dBm level that have passed thedetection (CRC, S/N) in the BTS.

    See figure CCCH load indication.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003017: RES ACC DENOMINATOR 4

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    2.18 003017 / RES ACC DENOMINATOR 4

    Counter ID: 003017 Network element name: RES ACC DENOMINATOR 4

    Version: 2.1 NetAct name: RES_ACC_DENOM4

    Description: Denominator of the average number of RACH accesses (always > 0).

    Counter 003016 is updated along with this counter.

    Updated: See figure CCCH load indication.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003016: AVE RACH ACCESS COUNT

    Operability class:

    24 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S1 Definition updated in release:

    2.19 003018 / MIN PAGING BUF

    Counter ID: 003018 Network element name: MIN PAGING BUF

    Version: 2.1 NetAct name: MIN_PAGING_BUF

    Description: Minimum size of the paging buffer on a CCCH (Peak value of the average PCH load: thesmaller the value, the greater the load on the PCH).Updated: When the value of the PCH load with the size of the paging buffer received in aCCCH_LOAD_INDICATION message from the BTS is smaller than the previous value during ameasurement period. 0xFFFFFFFF means unknown.

    See figure CCCH load indication.

    Logical type: Min Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S2 Definition updated in release:

    2.20 003019 / SDCCH LOC UPD

    Counter ID: 003019 Network element name: SDCCH LOC UPD

    Version: 2.1 NetAct name: SDCCH_LOC_UPD

    Description: Number of successful seizures of SDCCHs for location update.

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 25 (81)

    Counters of Resource Access Measurement

  • Updated: When an ESTABLISH_INDICATION message with request for a location update is receivedon SDCCH from the BTS.

    See figure Basic call with counters.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S2 Definition updated in release:

    2.21 003020 / SDCCH CALL RE EST

    Counter ID: 003020 Network element name: SDCCH CALL RE EST

    Version: 2.1 NetAct name: SDCCH_CALL_RE_EST

    Description: Number of successful SDCCH seizures for call re-establishment attempts.

    Updated: When an ESTABLISHMENT_INDICATION message for a call re-establishment is receivedon SDCCH from the BTS. Note that this counter counts only the number of re-establisment attemptson SDCCH. Counter 057022 gives the number of SDCCH re-establishment assignments.

    See figure Basic call with counters.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S3 Definition updated in release:

    26 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • 2.22 003021 / SDCCH EMERG CALL

    Counter ID: 003021 Network element name: SDCCH EMERG CALL

    Version: 2.1 NetAct name: SDCCH_EMERG_CALL

    Description: Number of successful seizures of SDCCHs for an emergency call.

    Updated: When an ESTABLISH_INDICATION message for an emergency call is received on SDCCHfrom the BTS.

    See figure Basic call with counters.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S3 Definition updated in release:

    2.23 003022 / TCH EMERG CALL

    Counter ID: 003022 Network element name: TCH EMERG CALL

    Version: 2.1 NetAct name: TCH_EMERG_CALL

    Description: Number of successful seizures of TCHs for an emergency call in FACCH call setup dueto SDCCH congestion. If the FACCH call setup is turned off, the counter value is zero.

    Updated: When an ESTABLISH_INDICATION message for an emergency call is received on TCHfrom the BTS.

    See figure FACCH call setup due to SDCCH congestion

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature:

    BSS5290: FACCH Call Setup due to SDCCH Congestion

    Related to standard:

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 27 (81)

    Counters of Resource Access Measurement

  • 3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S3 Definition updated in release: S5

    2.24 003023 / TCH MTC

    Counter ID: 003023 Network element name: TCH MTC

    Version: 2.1 NetAct name: TCH_MTC

    Description: Number of successful seizures of TCHs for MTC in FACCH call setup due to SDCCHcongestion. If the FACCH call setup is turned off, the counter value is zero.

    Updated: When an ESTABLISH_INDICATION message with a paging response is received on TCHfrom the BTS.

    See figure FACCH call setup due to SDCCH congestion

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature:

    BSS5290: FACCH Call Setup due to SDCCH Congestion

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S3 Definition updated in release: S5

    2.25 003024 / TCH MOC

    Counter ID: 003024 Network element name: TCH MOC

    Version: 2.1 NetAct name: TCH_MOC

    Description: Number of successful seizures of TCHs for MOC in FACCH call setup due to SDCCHcongestion. If the FACCH call setup is turned off, the counter value is zero.

    28 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Updated: When an ESTABLISH_INDICATION message with a request for CM service is received onTCH from the BTS.

    See figure FACCH call setup due to SDCCH congestion

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature:

    BSS5290: FACCH Call Setup due to SDCCH Congestion

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S3 Definition updated in release: S5

    2.26 003025 / TCH CALL RE EST

    Counter ID: 003025 Network element name: TCH CALL RE EST

    Version: 2.1 NetAct name: TCH_CALL_RE_EST

    Description: Number of successful TCH seizures for call re-establishment attempts in FACCH callsetup due to SDCCH congestion. If the FACCH call setup is turned off, the counter value is zero.

    Updated: When an ESTABLISH_INDICATION message for a call re-establishment is received on TCHfrom the BTS. Note that this counter counts only the number of re-establisment attempts on TCH.Counter 057032 gives the number of TCH re-establishment assignments.

    See figure FACCH call setup due to SDCCH congestion

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature:

    BSS5290: FACCH Call Setup due to SDCCH Congestion

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 29 (81)

    Counters of Resource Access Measurement

  • Exceptions to related standard:

    Used from release: S3 Definition updated in release: S5

    2.27 003026 / SUCC TCH SMS EST

    Counter ID: 003026 Network element name: SUCC TCH SMS EST

    Version: 2.1 NetAct name: SUCC_TCH_SMS_EST

    Description: Number of SMSs successfully established on a TCH.

    Updated: When an ESTABLISH_INDICATION message (mobile originating SMS) or anESTABLISH_CONFIRM message (mobile terminating SMS) is received on TCH from the BTS.

    See figures:- Mobile originating SMS on a TCH- Mobile terminating SMS on a TCH- Mobile originating SMS on FACCH- Mobile terminating SMS on FACCH

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S3 Definition updated in release:

    2.28 003027 / UNSUCC TCH SMS EST

    Counter ID: 003027 Network element name: UNSUCC TCH SMS EST

    Version: 2.1 NetAct name: UNSUCC_TCH_SMS_EST

    Description: Number of unsuccessful establishments of SMSs on a TCH.

    30 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Updated: When establishment of SMS fails on TCH.

    See figures:- Mobile originating unsuccessful SMS on a TCH- Mobile terminating unsuccessful SMS on a TCH- Mobile originating unsuccessful SMS on FACCH- Mobile terminating unsuccessful SMS on FACCH

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S3 Definition updated in release:

    2.29 003028 / SUCC SDCCH SMS EST

    Counter ID: 003028 Network element name: SUCC SDCCH SMS EST

    Version: 2.1 NetAct name: SUCC_SDCCH_SMS_EST

    Description: Number of SMSs successfully established on an SDCCH.

    Updated: When an ESTABLISH_INDICATION message (mobile originating SMS) or anESTABLISH_CONFIRM message (mobile terminating SMS) is received on SDCCH from the BTS.

    See figures:- Mobile originating SMS on an SDCCH- Mobile terminating SMS on an SDCCH

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S3 Definition updated in release:

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 31 (81)

    Counters of Resource Access Measurement

  • 2.30 003029 / UNSUCC SDCCH SMS EST

    Counter ID: 003029 Network element name: UNSUCC SDCCH SMS EST

    Version: 2.1 NetAct name: UNSUCC_SDCCH_SMS_EST

    Description: Number of unsuccessful establishments of SMSs on an SDCCH.

    Updated: When the establishment of an SMS fails on SDCCH.

    See figures:- Mobile originating unsuccessful SMS on an SDCCH- Mobile terminating unsuccessful SMS on an SDCCH

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S3 Definition updated in release:

    2.31 003030 / GHOST CCCH RES

    Counter ID: 003030 Network element name: GHOST CCCH RES

    Version: 2.1 NetAct name: GHOST_CCCH_RES

    Description: Number of ghost reservations on a CCCH.

    See also counter 003031.

    Updated: When a ghost reservation is detected on a CCCH. This kind of random access can becaused, for example, by white noise or co-channel interference. Note that the ghosts triggering thiscounter have illegal establishment cause. Ghost accessess with legal establishment cause get onSDCCH and later fail typically causing the triggering of counter 0010075.

    See figure Ghost reservation

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    32 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Dependencies with other counters:

    003031: REJ SEIZ ATT DUE DIST

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S3 Definition updated in release:

    2.32 003031 / REJ SEIZ ATT DUE DIST

    Counter ID: 003031 Network element name: REJ SEIZ ATT DUE DIST

    Version: 2.1 NetAct name: REJ_SEIZ_ATT_DUE_DIST

    Description: Number of seizure attempts rejected due to distance.

    Counter 003030 is updated along with this counter.

    Updated: When random access is rejected by the BSC because of a too long distance between theMS and BTS. This kind of random access can be caused, for example, by white noise or co-channelinterference.

    See figure Ghost reservation

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003030: GHOST CCCH RES

    Operability class:

    Related to feature:

    BSS5280: Distance Checking in Resource Allocation

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S5 Definition updated in release:

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 33 (81)

    Counters of Resource Access Measurement

  • 2.33 003032 / TRX IN EXT AREA

    Counter ID: 003032 Network element name: TRX IN EXT AREA

    Version: 2.1 NetAct name: TRX_TYPE

    Description: Normal TRX / extended TRX

    0 = normal area1= extended area

    Updated:

    Logical type: Variable Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature:

    BSS6037: Extended Cell Range

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S6 Definition updated in release:

    2.34 003033 / IMSI DETACH SDCCH

    Counter ID: 003033 Network element name: IMSI DETACH SDCCH

    Version: 2.1 NetAct name: IMSI_DETACH_SDCCH

    Description: Number of successful seizures of SDCCHs for IMSI detach.

    Updated: When an ESTABLISH_INDICATION message for an IMSI detach is received on SDCCHfrom the BTS.

    See figure Basic call with counters

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    34 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Operability class:

    Related to feature:

    BSS7042: Measurement Improvements

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S7 Definition updated in release:

    2.35 003034 / IMSI DETACH TCH

    Counter ID: 003034 Network element name: IMSI DETACH TCH

    Version: 2.1 NetAct name: IMSI_DETACH_TCH

    Description: Number of successful seizures of TCHs for IMSI detach in FACCH call setup due toSDCCH congestion. If the FACCH call setup is turned off, then the counter value is zero.

    Updated: When an ESTABLISH_INDICATION message for an IMSI detach is received on TCH fromthe BTS.

    See figure FACCH call setup due to SDCCH congestion

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature:

    BSS7042: Measurement Improvements

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S7 Definition updated in release:

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 35 (81)

    Counters of Resource Access Measurement

  • 2.36 003035 / MAX PAGING BUFFER CAPA

    Counter ID: 003035 Network element name: MAX PAGING BUFFER CAPA

    Version: 2.1 NetAct name: MAX_PAGING_BUFFER_CAPA

    Description: Maximum percent of paging buffer capacity. This counter indicates maximum pagingbuffer occupancy percentage during the reporting period. The range of this counter is 0-100% with 1%intervals.

    Updated: When the value of the maximum paging buffer received in a CCCH_LOAD_INDICATIONmessage exceeds the previous value of the paging buffer during a measurement period.

    See figure CCCH load indication

    Logical type: Max Trigger type: Event Sampling interval:

    Unit: % Range: 0-100 Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature:

    BSS7048: CCCH Improvements

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S7 Definition updated in release:

    2.37 003036 / AVE PAGING BUFFER CAPA

    Counter ID: 003036 Network element name: AVE PAGING BUFFER CAPA

    Version: 2.1 NetAct name: AVE_PAGING_BUFFER_CAPA_NUMER

    Description: The sum of the average paging buffer occupancy percentages. Each time a CCCH loadreporting period ends, the occupancy percentage is calculated and reported in a CCCH LOADINDICATION message. The average is calculated with (100*N)/N(max)%, where N is the occupiedbuffer space and N(max) is the maximum buffer space during the CCCH load reporting period.

    The CCCH load reporting period is the time between CCCH LOAD INDICATION message sendings.This counter stores the sum of the average paging buffer values received in CCCH LOADINDICATION messages.

    Counter 003037 is updated along with this counter.

    36 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Updated: When a CCCH LOAD INDICATION message is received from the BTS. The average pagingbuffer value is added to the previous value.

    See figure CCCH load indication.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: % Range: Example values:

    Dependencies with other counters:

    003037: RES ACC DENOMINATOR 5

    Operability class:

    Related to feature:

    BSS7048: CCCH Improvements

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S7 Definition updated in release:

    2.38 003037 / RES ACC DENOMINATOR 5

    Counter ID: 003037 Network element name: RES ACC DENOMINATOR 5

    Version: 2.1 NetAct name: AVE_PAGING_BUFFER_CAPA_DENOM

    Description: Denominator of the counter 003036 AVE PAGING BUFFER CAPA (always > 0).

    Counter 003036 is updated along with this counter.

    Updated: When a CCCH LOAD INDICATION message is received from the BTS and the averagepaging buffer occupancy percentage is reported in the message.

    See figure CCCH load indication.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003036: AVE PAGING BUFFER CAPA

    Operability class:

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 37 (81)

    Counters of Resource Access Measurement

  • Related to feature:

    BSS7048: CCCH Improvements

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S7 Definition updated in release:

    2.39 003038 / DELETE PAGING COMMAND

    Counter ID: 003038 Network element name: DELETE PAGING COMMAND

    Version: 2.1 NetAct name: DELETE_PAGING_COMMAND

    Description: Number of the delete paging commands. This counter indicates if some group-specificpaging queue becomes so full that an additional paging command cannot be stored to the buffer. Insuch a case the paging command is deleted.

    The message reports the total amount of such deleted paging commands during the reporting period.

    Updated: When a CCCH_LOAD_INDICATION message is received from the BTS and the pagingcommand is deleted.

    See figure CCCH load indication

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature:

    BSS7048: CCCH Improvements

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S7 Definition updated in release:

    38 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • 2.40 003039 / BCSU OVERLOAD LOWER LIMIT

    Counter ID: 003039 Network element name: BCSU OVERLOAD LOWER LIMIT

    Version: 2.1 NetAct name: BCSU_OVERLOAD_LOWER_LIMIT

    Description: Number of refused calls, when BCSU overload lower limit occurs. When the overloadlower limit occurs, all calls except emergency, MOC and MTC calls are refused.

    Updated: When the call is refused due to BCSU overload lower limit. Each time a newCHANNEL_REQUIRED message comes from the BTS through the Abis interface, a softwareapplication in the BCSU checks the number of free message buffers in the unit. When the lower limit(more than 34 unhandled messages) is exceeded, the causes moc_data, location_update,other_cases and re_establishment will be omitted.

    See figure Unsuccessful channel requests due to BCSU overload

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S7 Definition updated in release:

    2.41 003040 / BCSU OVERLOAD UPPER LIMIT

    Counter ID: 003040 Network element name: BCSU OVERLOAD UPPER LIMIT

    Version: 2.1 NetAct name: BCSU_OVERLOAD_UPPER_LIMIT

    Description: Number of refused calls, when BCSU overload upper limit occurs. When the overloadupper limit occurs, all calls are refused.

    Updated: When the call is refused due to BCSU overload upper limit. Each time a newCHANNEL_REQUIRED message comes from the BTS through the Abis interface, a softwareapplication in the BCSU checks the number of free message buffers in the unit. When the upper limit(more than 53 unhandled messages) is exceeded, no causes will trigger channel reservation in theBSC.

    See figure Unsuccessful channel requests due to BCSU overload

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 39 (81)

    Counters of Resource Access Measurement

  • Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S7 Definition updated in release:

    2.42 003041 / BCSU OVERLOAD DELETED RACH

    Counter ID: 003041 Network element name: BCSU OVERLOAD DELETEDRACH

    Version: 2.1 NetAct name: BCSU_OVERLOAD_DELETED_RACH

    Description: Number of deleted RACHs on a CCCH when the RACH load is too high and MCMU isprotected against overload.

    Updated: When new RACH commands arrive to the CCCH but the maximum number of simultaneousRACH requests have already been sent to the MCMU and therefore there is no free space for anynew RACH requests and the commands are deleted. The maximum number of simultaneous RACHrequests is dynamically changed at BCSU level according to the load of the MCMU. If there are morerequests, the RACHs are deleted and this counter is triggered.

    See figure Unsuccessful channel requests due to BCSU overload

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S7 Definition updated in release: S11.5

    2.43 003042 / TRX DIAGNOSTICS

    Counter ID: 003042 Network element name: TRX DIAGNOSTICS

    40 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Version: 2.1 NetAct name: TRX_DIAGNOSTIC

    Description: Number of the running times of TRX internal diagnostics.

    Updated: When TRX internal diagnostics is started. The base station has requested the blocking ofthe TRX for diagnostics.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature:

    BSS8143: Runtime diagnostics and BTS alarms

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S8 Definition updated in release:

    2.44 003043 / TRX DIAGNOSTICS FAULT

    Counter ID: 003043 Network element name: TRX DIAGNOSTICS FAULT

    Version: 2.1 NetAct name: TRX_DIAGNOSTIC_FAULT

    Description: Number of times that the TRX internal diagnostics has detected a fault.

    Updated: When diagnostics is stopped after fault detection. The BTS has sent a message informingthat the diagnostics has been stopped and that a fault has been detected.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature:

    BSS8143: Runtime diagnostics and BTS alarms

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S8 Definition updated in release:

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 41 (81)

    Counters of Resource Access Measurement

  • 2.45 003044 / SUCC SEIZ SUPPLEM SERV

    Counter ID: 003044 Network element name: SUCC SEIZ SUPPLEM SERV

    Version: 2.1 NetAct name: SUCC_SEIZ_SUPPLEM_SERV

    Description: Number of successful seizures of SDCCHs for supplementary service.

    Updated: When an ESTABLISH_INDICATION message with CM service request and service typesupplementary service is received on SDCCH from the BTS.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S9 Definition updated in release:

    2.46 003045 / TCH SUPPLEM SERV

    Counter ID: 003045 Network element name: TCH SUPPLEM SERV

    Version: 2.1 NetAct name: TCH_SUPPLEM_SERV

    Description: Number of successful seizures of TCHs for supplementary service in FACCH call setupdue to SDCCH congestion. If FACCH call setup is turned off, the counter value is zero.

    Updated: When an ESTABLISH_INDICATION message with CM service request and service typesupplementary service is received on TCH from the BTS.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    42 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Exceptions to related standard:

    Used from release: S9 Definition updated in release:

    2.47 003046 / AVE PCH GB LOAD ON CCCH

    Counter ID: 003046 Network element name: AVE PCH GB LOAD ON CCCH

    Version: 2.1 NetAct name: AVE_PCH_GB_LOAD_ON_CCCH_SUM

    Description: Average paging buffer space on Gb-interface. The counter indicates the remaining spacefor paging commands (CS, PS) and DRX Access Grant. Smaller value means greater load on thePCH.

    Counter 003047 is updated along with this counter.

    Updated: When the value of the PCH Gb load is received in a CCCH_LOAD_IND message from theBTS during the measurement period. The new value of the PCH Gb load is added to the previousvalue, and the number of events is increased by one.

    When CCCH_LOAD_IND message is received by BSC and GPRS support is configured on CCCH.See figure CCCH load indication if GPRS is activated in BTS and other conditions are valid.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003047: RES ACC DENOMINATOR 6

    Operability class:

    Related to feature:

    BSS9006: GPRS Telecom in BCSU and MCMU

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S9 Definition updated in release:

    2.48 003047 / RES ACC DENOMINATOR 6

    Counter ID: 003047 Network element name: RES ACC DENOMINATOR 6

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 43 (81)

    Counters of Resource Access Measurement

  • Version: 2.1 NetAct name: AVE_PCH_GB_LOAD_ON_CCCH_DEN

    Description: Denominator of average PCH Gb load on CCCH.

    Counter 003046 is updated along with this counter.

    Updated: See figure CCCH load indication if GPRS is activated in BTS and other conditions are valid

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003046: AVE PCH GB LOAD ON CCCH

    Operability class:

    Related to feature:

    BSS9006: GPRS Telecom in BCSU and MCMU

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S9 Definition updated in release:

    2.49 003048 / AVE PAGING GB BUF

    Counter ID: 003048 Network element name: AVE PAGING GB BUF

    Version: 2.1 NetAct name: AVE_PAGING_GB_BUF_SUM

    Description: Average buffer occupancy percentage.

    It is used to carry information on the load of the PCH associated with this CCCH timeslot. Thisinformation reports the paging buffer occupancy percentages within the buffer area of approximately15 seconds, in case the GPRS support is configured onto CCCH. The range of this parameter is0...100% with 1% intervals. The occupancy percentage (occupied buffer space vs. maximum space) ofpaging buffer is calculated every fourth 51-multiframe. An average is calculated from these values andreported in CCCH_LOAD_IND message.

    Counter 003049 is updated along with this counter.

    Updated: When the value of the average paging Gb buffer load is received in a CCCH_LOAD_INDmessage from the BTS during measurement period. The new value of the average paging Gb bufferload is added to the previous value, and the number of events is increased by one.

    When CCCH_LOAD_IND message is received by BSC and GPRS support is configured on CCCH.See figure CCCH load indication if GPRS is activated in BTS and other conditions are valid

    44 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Logical type: Sum Trigger type: Event Sampling interval:

    Unit: % Range: 0 - 100 Example values:

    Dependencies with other counters:

    003049: RES ACC DENOMINATOR 7

    Operability class:

    Related to feature:

    BSS9006: GPRS Telecom in BCSU and MCMU

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S9 Definition updated in release:

    2.50 003049 / RES ACC DENOMINATOR 7

    Counter ID: 003049 Network element name: RES ACC DENOMINATOR 7

    Version: 2.1 NetAct name: AVE_PAGING_GB_BUF_DEN

    Description: Denominator of average buffer occupancy percentage.

    Counter 003048 is updated along with this counter.

    Updated: See figure CCCH load indication if GPRS is activated in BTS and other conditions are valid

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003048: AVE PAGING GB BUF

    Operability class:

    Related to feature:

    BSS9006: GPRS Telecom in BCSU and MCMU

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 45 (81)

    Counters of Resource Access Measurement

  • Exceptions to related standard:

    Used from release: S9 Definition updated in release:

    2.51 003050 / MAX PAGING GB BUF

    Counter ID: 003050 Network element name: MAX PAGING GB BUF

    Version: 2.1 NetAct name: MAX_PAGING_GB_BUF

    Description: Maximum buffer occupancy percentage.

    It is used to carry information on the load of the PCH associated with this CCCH timeslot. It is thepeak value of all values which are calculated every fourth 51-multiframe during the concernedCCCH_LOAD_IND reporting period. The range of this parameter is 0...100% with 1% intervals.

    Updated: When the value of the maximum paging buffer received in a CCCH_LOAD_INDICATIONmessage exceeds the previous value of the paging buffer during the measurement period.

    When CCCH_LOAD_IND message is received by BSC and GPRS support is configured on CCCH.See figure CCCH load indication if GPRS is activated in BTS and other conditions are valid

    Logical type: Max Trigger type: Event Sampling interval:

    Unit: % Range: 0 - 100 Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature:

    BSS9006: GPRS Telecom in BCSU and MCMU

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S9 Definition updated in release:

    2.52 003051 / AVE PAGING LOAD AIR

    Counter ID: 003051 Network element name: AVE PAGING LOAD AIR

    Version: 2.1 NetAct name: AVE_PAGING_LOAD_AIR_SUM

    46 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Description: Average paging load on CCCH indicated by radio block occupancy for paging messages.

    Radio Block Occupancy carries information on the Radio interface load in percents of the associatedCCCH timeslot. The radio block occupancy percentage for AGCH messages requiring DRX (occupiedradio blocks vs. all radio blocks during reporting period) is calculated and reported in CCCH_LOAD_IND message.

    Counter 003052 is updated along with this counter.

    Updated: When a CCCH_LOAD_INDICATION message is received from the BTS. The averagepaging load value is added to the previous value and the number of events is increased by one.

    When CCCH_LOAD_IND message is received by BSC and phase 2 BTS or newer is supported. Seefigure CCCH load indication if GPRS is activated in BTS and other conditions are valid

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: % Range: 0 - 100 Example values:

    Dependencies with other counters:

    003052: RES ACC DENOMINATOR 8

    Operability class:

    Related to feature:

    BSS9006: GPRS Telecom in BCSU and MCMU

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S9 Definition updated in release:

    2.53 003052 / RES ACC DENOMINATOR 8

    Counter ID: 003052 Network element name: RES ACC DENOMINATOR 8

    Version: 2.1 NetAct name: AVE_PAGING_LOAD_AIR_DEN

    Description: Denominator of average radio interference CCCH load radio block occupancy paging.

    Counter 003051 is updated along with this counter.

    Updated: See figure CCCH load indication if GPRS is activated in BTS and other conditions are valid

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 47 (81)

    Counters of Resource Access Measurement

  • Dependencies with other counters:

    003051: AVE PAGING LOAD AIR

    Operability class:

    Related to feature:

    BSS9006: GPRS Telecom in BCSU and MCMU

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S9 Definition updated in release:

    2.54 003053 / AVE DRX AGCH LOAD AIR

    Counter ID: 003053 Network element name: AVE DRX AGCH LOAD AIR

    Version: 2.1 NetAct name: AVE_DRX_AGCH_LOAD_AIR_SUM

    Description: Average radio interference CCCH load radio block occupancy DRX AGCH.

    It is used to carry information on the Radio interface load of the associated CCCH timeslot. The rangeof this parameter is 0...100% with 1% intervals. The radio block occupancy percentage for AGCHmessages requiring DRX (occupied radio blocks vs. all radio blocks during reporting period) iscalculated and reported in CCCH_LOAD_ IND message.

    Counter 003054 is updated along with this counter.

    Updated: When a CCCH_LOAD_INDICATION message is received from the BTS. The average DRXAGCH LOAD AIR value is added to the previous value and the number of events is increased by one.

    When CCCH_LOAD_IND message is received by BSC and phase 2 BTS or newer is supported. Seefigure CCCH load indication if GPRS is activated in BTS and other conditions are valid

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: % Range: 0 - 100 Example values:

    Dependencies with other counters:

    003054: RES ACC DENOMINATOR 9

    Operability class:

    48 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Related to feature:

    BSS9006: GPRS Telecom in BCSU and MCMU

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S9 Definition updated in release:

    2.55 003054 / RES ACC DENOMINATOR 9

    Counter ID: 003054 Network element name: RES ACC DENOMINATOR 9

    Version: 2.1 NetAct name: AVE_DRX_AGCH_LOAD_AIR_DEN

    Description: Denominator of average radio interference CCCH load radio block occupancy DRXAGCH.

    Counter 003053 is updated along with this counter.

    Updated: See figure CCCH load indication if GPRS is activated in BTS and other conditions are valid

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003053: AVE DRX AGCH LOAD AIR

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S9 Definition updated in release:

    2.56 003055 / AVE NON DRX AGCH LOAD AIR

    Counter ID: 003055 Network element name: AVE NON DRX AGCH LOAD AIR

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 49 (81)

    Counters of Resource Access Measurement

  • Version: 2.1 NetAct name: AVE_NON_DRX_AGCH_LOAD_AIR_SUM

    Description: Average radio interference CCCH load radio block occupancy NON-DRX AGCH.

    It is used to carry information on the Radio interface load of the associated CCCH timeslot. The rangeof this parameter is 0...100% with 1% intervals. The radio block occupancy percentage for AGCHmessages not requiring DRX (occupied radio blocks vs. all radio blocks during reporting period) iscalculated and reported in CCCH_LOAD_ IND message.

    Counter 003056 is updated along with this counter.

    Updated: When a CCCH_LOAD_INDICATION message is received from the BTS. The average NONDRX AGCH LOAD AIR value is added to the previous value and the number of events is increased byone.

    When CCCH_LOAD_IND message is received by BSC and phase 2 BTS or the newer is supported.See figure CCCH load indication if GPRS is activated in BTS and other conditions are valid

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: % Range: 0 - 100 Example values:

    Dependencies with other counters:

    003056: RES ACC DENOMINATOR 10

    Operability class:

    Related to feature:

    BSS9006: GPRS Telecom in BCSU and MCMU

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S9 Definition updated in release:

    2.57 003056 / RES ACC DENOMINATOR 10

    Counter ID: 003056 Network element name: RES ACC DENOMINATOR 10

    Version: 2.1 NetAct name: AVE_NON_DRX_AGCH_LOAD_AIR_DEN

    Description: Denominator of average radio interference CCCH load radio block occupancy NON-DRXAGCH.

    Counter 003055 is updated along with this counter.

    Updated: See figure CCCH load indication if GPRS is activated in BTS and other conditions are valid

    Logical type: Sum Trigger type: Event Sampling interval:

    50 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003055: AVE NON DRX AGCH LOAD AIR

    Operability class:

    Related to feature:

    BSS9006: GPRS Telecom in BCSU and MCMU

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S9 Definition updated in release:

    2.58 003057 / PS PAGING MSG SENT

    Counter ID: 003057 Network element name: PS PAGING MSG SENT

    Version: 2.1 NetAct name: PS_PAGING_MSG_SENT

    Description: This message is sent from the BSC/PCU to the BTS to request PS paging of a GPRSMS.

    Updated: When a PS-PAGING COMMAND message is sent to the BTS. The MS needs to be pagedonly when it is in MM-idle state. A GPRS paging message is sent only to cells that support GPRSservices.

    When a PS-PAGING COMMAND message is sent from the BSC to the BTS. See figure PS paging inGPRS

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature:

    BSS9006: GPRS Telecom in BCSU and MCMU

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 51 (81)

    Counters of Resource Access Measurement

  • Used from release: S9 Definition updated in release:

    2.59 003058 / CS PAGING MSG SENT

    Counter ID: 003058 Network element name: CS PAGING MSG SENT

    Version: 2.1 NetAct name: CS_PAGING_MSG_SENT

    Description: This message is sent from BSC/PCU to BTS to request CS paging of a GPRS MS.

    Updated: When a CS-PAGING COMMAND is sent to the BTS.

    When a CS-PAGING COMMAND message is sent from BSC to the BTS. See figure CS Paging inGPRS

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature:

    BSS9006: GPRS Telecom in BCSU and MCMU

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S9 Definition updated in release:

    2.60 003059 / CALL ASSIGN AFTER SMS

    Counter ID: 003059 Network element name: CALL ASSIGN AFTER SMS

    Version: 2.1 NetAct name: CALL_ASSIGN_AFTER_SMS

    Description: Number of calls started directly after an SMS on the already reserved SDCCH.

    Updated: When an ASSIGNMENT REQUEST message is received directly after a successful SMS onSDCCH from the MSC.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    52 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S10.5 Definition updated in release:

    2.61 003060 / SPARE003060

    Counter ID: 003060 Network element name: SPARE003060

    Version: 2.0 NetAct name: SPARE003060

    Description: Spare

    Updated:

    Logical type: Trigger type: Sampling interval:

    Unit: Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S10.5 Definition updated in release:

    2.62 003061 / SPARE003061

    Counter ID: 003061 Network element name: SPARE003061

    Version: 2.0 NetAct name: SPARE003061

    Description: Spare

    Updated:

    Logical type: Trigger type: Sampling interval:

    Unit: Range: Example values:

    Dependencies with other counters:

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 53 (81)

    Counters of Resource Access Measurement

  • Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S10.5 Definition updated in release:

    2.63 003062 / SPARE003062

    Counter ID: 003062 Network element name: SPARE003062

    Version: 2.0 NetAct name: SPARE003062

    Description: Spare

    Updated:

    Logical type: Trigger type: Sampling interval:

    Unit: Range: Example values:

    Dependencies with other counters:

    Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S10.5 Definition updated in release:

    2.64 003063 / SPARE003063

    Counter ID: 003063 Network element name: SPARE003063

    Version: 2.0 NetAct name: SPARE003063

    Description: Spare

    Updated:

    Logical type: Trigger type: Sampling interval:

    Unit: Range: Example values:

    Dependencies with other counters:

    54 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Operability class:

    Related to feature: Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S10.5 Definition updated in release:

    2.65 003064 / SUCC MO SMS SDCCH

    Counter ID: 003064 Network element name: SUCC MO SMS SDCCH

    Version: 2.1 NetAct name: SUCC_MO_SMS_SDCCH

    Description: Number of mobile originated SMSs successfully established on an SDCCH.

    Counter 003028 is updated together with this counter.

    Updated: At the same time as counter 003028 (SUCC SDCCH SMS EST) but only when ESTABLISHINDICATION message for a mobile originated SMS is received on SDCCH from the BTS.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003028: SUCC SDCCH SMS EST

    Operability class:

    Related to feature:

    BSS115168: CS Statistics Improvements

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S11.5 Definition updated in release:

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 55 (81)

    Counters of Resource Access Measurement

  • 2.66 003065 / UNSUCC MO SMS SDCCH

    Counter ID: 003065 Network element name: UNSUCC MO SMS SDCCH

    Version: 2.1 NetAct name: UNSUCC_MO_SMS_SDCCH

    Description: Number of mobile originated SMSs unsuccessfully established on an SDCCH.

    Counter 003029 is updated together with this counter.

    Updated: At the same time as counter 003029 (UNSUCC SDCCH SMS EST) but only whenESTABLISH INDICATION message for a mobile originated SMS is received on SDCCH from the BTS.

    Logical type: Sum Trigger type: Event Sampling interval:

    Unit: Integer number Range: Example values:

    Dependencies with other counters:

    003029: UNSUCC SDCCH SMS EST

    Operability class:

    Related to feature:

    BSS115168: CS Statistics Improvements

    Related to standard:

    3GPP Measurement name (Clause header):3GPP Measurement type:

    Exceptions to related standard:

    Used from release: S11.5 Definition updated in release:

    56 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • 3 Signalling charts of Resource AccessMeasurement

    The following figures show the signalling charts of Resource AccessMeasurement:

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 57 (81)

    Signalling charts of Resource Access Measurement

  • Figure 1. Basic call without counters.

    BSC:MS: BTS: MSC:

    PagingPaging commandPaging request

    Channel requestChannel required

    Channel activation

    Immediate assign

    SetupSetup

    Call proceeding Call proceeding

    Assignment requestPhysical context request

    Physical context confirm

    Channel activation

    Channel activation ack

    Assignment command

    Ua

    Sabm Establish indication

    Ua

    Assignment complete Assignment complete

    Rf channel release

    Rf channel release ack

    Identification requestIdentification request

    Identification response Identification response

    Encryption command

    Paging part

    Radio access part on CCCH

    Channel activation ack

    Immediate assign command

    Sabm Establish indication Paging response

    Authentication requestAuthentification request

    Authentification response

    SDCCH signalling part

    DDCH establishment part

    TCH seized, FACCH signalling part

    Ciphering mode command

    Ciphering mode complete

    Authentication response

    Ciphering mode command

    Ciphering mode complete

    58 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Figure 2. Basic call without counters (cont.).

    Alert Alert

    Connect Connect

    Connect ackConnect ack

    Release complete

    Clear command

    Clear complete

    Channel release

    Deactivate SACCH

    Ua

    Release indication

    Rf channel release

    Rf channel release ack

    Disconnect Disconnect

    ReleaseRelease

    Release complete

    BSC:MS: BTS: MSC:

    Disc

    Conversation phase

    Release by MS

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 59 (81)

    Signalling charts of Resource Access Measurement

  • Figure 3. Basic call with counters.

    BTS: MSC:MS: BSC:

    PagingPaging command

    Paging request

    Channel request

    Channel required

    Channel activation

    Channel activation ack

    Immediate assign

    SabmEstablish indication

    Paging responseUa

    Paging part

    Paging messages sent to BTS003000

    Radio access part on CCCH

    Channel request messagesreceived from BTS

    003004

    Immediate assign command

    Immediate assignment messagesent to BTS003001

    DDCH establishment part

    SDCCH signalling part

    TCH seized, FACCH signalling part

    Conversation phase

    Release by MS

    Success seizure for MTC003012

    or Success seizure for MOC003013

    or SDCCH location update003019

    or SDCCH call re-establishment003020

    or SDCCH emergency call003021

    or IMSI detach SDCCH003033

    60 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Figure 4. FACCH call setup due to SDCCH congestion.

    BTS:MS: BSC: MSC:

    Sabm

    Establish indication

    Paging response

    Ua

    Radio access part on CCCH

    Paging part

    DDCH establishment part

    TCH signalling part

    Conversation phase

    Release by MS

    TCH emergency call003022

    orTCH MTC003023

    orTCH MOC003024

    orTCH call re-establishm.

    003025or

    IMSI detach TCH003034

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 61 (81)

    Signalling charts of Resource Access Measurement

  • Figure 5. Ghost reservation.

    Counter 003031 is updated if distance verifying is activated in the resourceallocation feature and the channel request is rejected due to the distancebetween the MS and BTS.

    Ghost

    Channel required

    BSC:MS: MSC:BTS:

    Radio access part on CCCH

    Paging part

    Rej seiz att due dist

    003031

    GHOST CCCH reservation

    003030

    Channel request messages

    received from BTS

    003004

    62 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Figure 6. Busy AGCH-channel.

    Channel required

    Channel activation

    Channel request

    Delete indication

    MS: BSC: MSC:BTS:

    Radio access part on CCCH

    Paging part

    Channel activation ack

    Immediate assign command

    Immediate assignmentmessages sent to BTS

    003001

    Delete indication messagesreceived from BTS

    003005

    Channel request messagesreceived from BTS

    003004

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 63 (81)

    Signalling charts of Resource Access Measurement

  • Figure 7. Unsuccessful channel request.

    Figure 8. SMS broadcast.

    Channel required

    Channel request

    BSC:MS: MSC:BTS:

    Radio access part on CCCH

    Paging part

    Immediate assignment reject

    Channel request messagesreceived from BTS

    003004

    Immediate assignment rejectmessages sent to BTS

    003002

    BSC:MS: MSC:BTS:

    SMS broadcast request

    SMS broadcast request

    SMS broadcast request

    SMS broadcast request

    SMS CB request messagessent to the BTS

    003003

    64 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Figure 9. Mobile originating SMS on a TCH.

    Cp data

    Cm serv req

    Ua (SAPI = 3)

    Sabm (SAPI = 3)

    Establish indication

    Cp data

    Cp ack Cp ack

    Cp data Cp data

    Cp ackCp ack

    Cm serv req

    Cm serv ackCm serv ack

    BSC:MS: MSC:BTS:

    Active call

    Successful TCH SMS003026

    Active call continuous

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 65 (81)

    Signalling charts of Resource Access Measurement

  • Figure 10. Mobile terminating SMS on a TCH.

    Cp data

    Establish request

    Sabm (SAPI = 3)

    Ua (SAPI = 3)

    Establish confirm

    Cp data

    Cp ack Cp ack

    Cp data Cp data

    Cp ackCp ack

    BTS: MSC:MS: BSC:

    Active call

    Active call continuous

    Successful TCH SMS003026

    66 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Figure 11. Mobile originating SMS on FACCH.

    MS starts SMS by sending SABM with SAPI = 3

    SMS release

    Cp ack

    Cp ack

    Cp data

    Cp data

    Cp ack

    Cp ack

    Cp data

    Establish indication

    Sabm (SAPI = 3)

    FACCH call setup

    Ua (SAPI = 3)

    Instead of sending SETUP -message,

    Cp data

    BSC:MS: MSC:BTS:

    Successful TCH SMS003026

    DN9813745Issue 10-0 en18/03/2008

    # Nokia Siemens Networks 67 (81)

    Signalling charts of Resource Access Measurement

  • Figure 12. Mobile terminating SMS on FACCH.

    Establish request

    MSC starts SMS by sending CP DATA -message

    SMS release

    Cp ack

    Cp ack

    Cp data

    Cp data

    Cp ack

    Cp ack

    Cp data

    Establish confirm

    Ua (SAPI = 3)

    FACCH call setup

    Sabm (SAPI = 3)

    Instead of sending SETUP -message,

    Cp data

    BTS: MSC:MS: BSC:

    Successful TCH SMS003026

    68 (81) # Nokia Siemens Networks DN9813745Issue 10-0 en

    18/03/2008

    3 Resource Access Measurement

  • Figure 13. Mobile originating SMS on an SDCCH.

    Cp data

    Ua (SAPI = 3)

    Sabm (SAPI = 3)

    Establish indication

    Cp data

    Cp ack Cp ack

    Cp data Cp data

    Cp ackCp ack

    BTS: MSC:MS: BSC:

    Instead of sending SETUP -message,

    Connection is set up as in normal MOC

    S