Top Banner
RESERVE SOCIETE SUMARE PAYLOAD TM S SA S 00/S/ED A /N C/088 -M P
15

RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

Jan 18, 2016

Download

Documents

Maria Hamilton
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

RESERVE SOCIETE

SUMARE PAYLOAD

TMS SAS 00/S/EDA/NC/088 - MP

Page 2: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

RESERVE SOCIETE

CONTENTS

• Objectives.

• Sensors choice.

• Sensors performances.

• Implant possibilities.

• Sensors conditioning.

• Schedule.

• Sensors integration drawings.

• Fins navigation trials.

• Fresh water tank measurement sensors.

2

TMS SAS 00/S/EDA/NC/088 - MP

Page 3: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

RESERVE SOCIETE

OBJECTIVES

The “Payload” will assume two main operational functions.

• Monitoring of the volumetric evolution of sand banks.

• Obstacles avoidance.

3

TMS SAS 00/S/EDA/NC/088 - MP

Page 4: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

RESERVE SOCIETE

SENSORS CHOICE

Altimeter.

Acoustic high frequency transducer ( Resolution)

Obstacles avoidance.

The inner Mauve transducer is not available (Software limits / Discrimination).

The transducer is the same than for altimeter.

4

TMS SAS 00/S/EDA/NC/088 - MP

Page 5: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

RESERVE SOCIETE

5

TMS SAS 00/S/EDA/NC/088 - MP

SENSORS PERFORMANCES

Measurement limit : 50 m

Measurement mode : Free run

Measurement speed : 10 Hz

Power supply : 12 or 24 VDC

Interface : RS 232 or RS 485

Frequency : 500 kHz

Conical beam : 6°

Page 6: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

RESERVE SOCIETE

TMS SAS 00/S/EDA/NC/088 - MP

IMPLANT POSSIBILITIES

1 : Risk on Payload structure (depth)

Obstacle avoidance sensor not possible.

2 : Risk on launching.

3 : chosen solution

6

1

2

3

Page 7: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

RESERVE SOCIETE

SENSORS CONDITIONING

Conditioning electronic : two output

Two output are available on MMNS

1 RS 232

1 RS 485

The two electronic signal conditioning units will be connected on these outputs

7

TMS SAS 00/S/EDA/NC/088 - MP

Page 8: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

RESERVE SOCIETE

SCHEDULE

8

TMS SAS 00/S/EDA/NC/088 - MP

2000 20015 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12

fins dummy productionVillefranche Fins dummy navigation sea trials Measurement system specificationPayload implant proposalfins prototype productionVillefranche Fins prototype navigation sea trials Software / Payload validatePayload productionFresh water tank Payload measurementVillefranche sea trials

Page 9: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

RESERVE SOCIETE

SENSORS INTEGRATION.

4 configurations will be tested at sea.

• 1 :Fins 60 mm long in front of the payload.

• 2 :Fins 60 mm long in back of the payload.

• 3 :Fins 120 mm long in front of the payload.

• 4 :Fins 120 mm long in back of the payload.

9

TMS SAS 00/S/EDA/NC/088 - MP

Page 10: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

RESERVE SOCIETE

1 :Fins 60 mm long in front of the payload.10

TMS SAS 00/S/EDA/NC/088 - MP

FRONT VIEWSIDE VIEW

TOP VIEW

Page 11: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

RESERVE SOCIETE

1 :Fins 60 mm long in back of the payload.11

TMS SAS 00/S/EDA/NC/088 - MP

FRONT VIEWSIDE VIEW

TOP VIEW

Page 12: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

RESERVE SOCIETE

3 :Fins 120 mm long in front of the payload.12

TMS SAS 00/S/EDA/NC/088 - MP

FRONT VIEWSIDE VIEW

TOP VIEW

Page 13: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

RESERVE SOCIETE

4 :Fins 120 mm long in back of the payload.13

TMS SAS 00/S/EDA/NC/088 - MP

FRONT VIEWSIDE VIEW

TOP VIEW

Page 14: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

RESERVE SOCIETE

fins with their moulds14

TMS SAS 00/S/EDA/NC/088 - MP

Page 15: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning.

RESERVE SOCIETE

FRESH WATER TANK

MEASUREMENT SENSORS

15

TMS SAS 00/S/EDA/NC/088 - MP

Computer

Signal generatorPower amplifier

Amplifier

Oscilloscope

Rotating unit

Reference hydrophone