PVI-2000/3600 p. 24 PVI-3.0-TLp. 34

PVI-5000-TLp. 46

PVI-10.0-TLp. 60

PVI-3.6-TL PVI-6000-TL PVI-12.5-TLUNO-2.0-I

p. 28PVI-4.2-TL

UNO-2.5-IPVI-3.8-I

p. 40PVI-10.0-I

p. 54TRIO-27.6-TL

p. 64PVI-2000-OUTD p. 32 PVI-4.6-I PVI-12.0-I TRIO-20.0-TL

PVI-250.0-TLp. 70

PVI-55.0/110.0 p. 78 PVI-CENTRAL-50p. 84

PVI-ULTRA p. 94PVI-500.0-TL PVI-CENTRAL-100

PVI-165.0/220.0 p. 80

PVI-275.0/330.0 p. 82 PVI-CENTRAL-250p. 88

PVI-CENTRAL-300

MICRO-0.25-I MICRO-0.3-I

p. 12 OPTI-0.3-TL p. 18

STATION p. 100

AURORAp. 108

STRINGCOMB p. 114 PVI-AEC-EVO p. 122 AURORA p. 126VISION INSTALLER

AURORA p. 110 AURORA p. 120 PVI-DESKTOP p. 124UNIVERSAL ENVIRONMENTAL

LSWI-2.5MW p. 132 25kW WINDp. 144

4000 & 7200p. 156

SSWI-3.8-Ip. 166

INTERFACE WIND INTERFACE SSWI-4.6-IMSWI-55.0/110.0 p. 136

PVI-12.5-TL-W p. 148 PVI-5000-TL-Wp. 160

PVI-3.0-TL-Wp. 172MSWI-50/100-US p. 140 PVI-6000-TL-W PVI-3.6-TL-W

SSWI-10.0-I p. 152 PVI-4.2-TL-W

AURORAp. 180

AURORAp. 184

ADVANTAGE ALLIANCEAURORA

p. 178SERVICE

AURORAp. 182

AURORAp. 186

ASSURE ACADEMY

GLOBALMARKETOVERVIEW

p. 188 CONTACTS p. 196

Page 4: Renewable Energy Solutios

Central Inverter

Small Wind

Single Phase

RESIDENTIAL PV INVERTERS

UTILITY PV CENTRAL INVERTERS

55 kW - 1400 kW

MICRO-0.25-IMICRO-0.3-I

OPTI-0.3-TL PVI-2000PVI-3600

UNO-2.0-IUNO-2.5-I

PVI-3.0-TLPVI-3.6-TLPVI-3.8-I

PVI-250.0-TLPVI-500.0-TL

PVI-250-USPVI-300-US

ULTRA-700-TLULTRA-1050-TL ULTRA-1400-TL

SMALL WIND INVERTERS

PVI-3.0-TL-WPVI-3.6-TL-WPVI-4.2-TL-W

3 kW - 6 kWPVI-5000-TL-WPVI-6000-TL-W

SSWI-3.8-ISSWI-4.6-I

SSWI-10.0-IPVI-12.5-TL-W

4000 WIND INTERFACE7200 WIND INTERFACE25kW-WIND-INTERFACE

10 kW - 25 kW

300W - 4 kW

PVI-CENTRAL-50/100PVI-55.0/110.0PVI-165.0/220.0PVI-275.0/330.0

NEW NEW NEW

NEWNEW

Page 5: Renewable Energy Solutios

Medium Wind

MEDIUM WIND

Large Wind

VisionTurnkey Solutions

Three PhaseSingle Phase

COMMERCIAL PV INVERTERS

PV STATION

PVI-4.2-TLPVI-4.6-IPVI-5000-TLPVI-6000-TL

PVI-10.0-TLPVI-10.0-IPVI-12.0-IPVI-12.5-TL

TRIO-20.0-TLTRIO-27.6-TL

STATION 440/660-IT/DESTATION 770/1000-IT/DESTATION 1000/1320-IT/DE/US

PVI-AEC-EVO PVI-DESKTOP

LARGE WIND

55 kW - 110 kWMSWI-55.0MSWI-110.0

LSWI-2.5MW

turnkey solutions

4 kW - 30 kW

AURORA VISION

MSWI-50-USMSWI-100-US

AURORAUNIVERSAL

NEW

NEWNEW

AURORAENVIRONMENTAL

NEW

Page 6: Renewable Energy Solutios

Welcome

Page 7: Renewable Energy Solutios

As President of Power-One’s Renewable Energy Solutions, I am excited to showcase our broad array of products and services for the Solar and Wind markets.

Power-One has a long-standing history in the global power electronics industry, providing a four-decades strong foundation for our technology innovation, quality and service within the Renewable Energy industry.

If you are new to our products, we off er the full range of photovoltaic and wind products, from small residential inverters to large utility-grade units. From the contents of this brochure, you will fi nd that we off er a diverse range of solutions to meet the needs of every installation.

At Power-One, our objective is to be the best-in-class for on-time delivery, reliability and yield. Since 2009, our company has risen from the number nine position amongst the world’s solar inverter manufacturers to the number two global position, shipping 2.6 GW of inverters in 2010. With our global presence, including design, manufacturing, sales and service in Asia, Europe and the Americas, we off er fl exibility, regionally specifi c products and rapid manufacturing and service response times for our customers throughout the world.

Our broad array of Aurora products off ers industry leading effi ciency and reliability, providing customers with a technologically advanced product that produces higher yields than our competitors. In fact, Photon Magazine said our European 10.0kW three-phase inverter, which received their A+ rating, ‘takes its place among the top devices Photon Lab has tested so far’.

Coupled with our innovative technology, we also provide our customers with excellent pre- and post-sales service. This ensures their orders are not only correct to their specifi cation before they receive the product, but that they also have an effi cient care package for increased uptime throughout the life of the inverter. This enables us to be more of a partner than a supplier to our customers, as we like to think of ourselves as our customers’ manufacturing arm – no diff erent than if we were within their organizations.

On behalf of a very hard working team, we are looking forward to working with you as we provide our leading design, technology and service to meet your renewable energy needs. I encourage you to contact Power-One Renewable Energy Solutions team so that we can be the supplier of choice for all of your future renewable energy projects.

With best wishes

Dr. Alex Levran, President, Renewable Energy Solutions

Page 8: Renewable Energy Solutios

New Products & Product Benefits

This global catalogue introduces a certain number of new products to the Power-One Aurora range. So far we have installed products totaling more than 4 GW of power globally. We have redesigned the smallest of our residential inverters, the new UNO 2 kW single phase inverter. A new look inverter from both a style and technology standpoint, it is high performing, extremely robust, easily installed and features a new user interface. Other important news includes two new string inverter products for large roof top applications, TRIO-27.6 and TRIO-20.0, three-phase inverters outputting 27.6 kW and 20.0 kW respectively. These products fi ll a gap between our previous 10.0 kW and 12.5 kW three-phase products and our smallest Central inverter products (50kW and 55kW). This new design of inverter benefi ts from three-phase inverter technology perfected in the PVI-10.0 and 12.5, probably the world’s most commonly used three-phase inverter which has led the way in best-in-class effi ciency. Power-One is also launching the new ULTRA, our biggest inverter with an output of up to 1.4MW featuring passive liquid cooling. This new concept in large scale utility inverter features an IP65 enclosure, high performances, minimum footprint, low maintenance and Power-One’s traditional modular approach. All this plus a low operational cost benefi t for our customers.

Page 9: Renewable Energy Solutios

Key Features of the Aurora product range Power-One’s Aurora products compare favorably with the competition for the high innovation content and key features which are the stronghold of our offering. The wide working input voltage range can accommodate any panel string size, allowing installers to buy their inverter with confidence knowing the Aurora inverter will suit whatever installation they have on their books. The wide input range also allows a low power of activation to extend the daily working time of the inverter. The Aurora inverters also feature a rugged IP65 construction to fit any type of installation without putting restrictions on where and how the inverter should be installed. Maximum power-point trackers (MPPT) allow you to accommodate sub arrays with different orientations or made up of different PV panels. This technology also allows the installation designer to know that any incidents of partial shading will be overcome by the MPPT technology creating the optimum power curve for energy harvesting. Modular central inverters, used for large commercial and utility scale applications, allow a reduction in downtime caused either by the failure at the inverter level or the photovoltaic field. This eliminates plant shutdown, the reduction of repair time and consequently financial benefits in terms of production.At Power-One, we aim high so you can too.

Paolo CasiniVice President, Marketing

Page 10: Renewable Energy Solutios

10 AURORA MICRO

Page 11: Renewable Energy Solutios

MICR

OOP

TIMIZE

R

MICRO

11AURORA MICRO

Page 12: Renewable Energy Solutios

12 AURORA MICRO

MICRO-0.25-I MICRO-0.3-I

GENERAL SPECIFICATIONSOUTDOOR MODELS

MICRO-0.25-I-OUTD-230MICRO-0.25-I-OUTD-208/240

MICRO-0.3-I-OUTD-230MICRO-0.3-I-OUTD-208/240

NEW

Page 13: Renewable Energy Solutios

13AURORA MICRO

Features‘Electrolyte-free’ power converter to further increase the life expectancy and long term reliabilityOutdoor enclosure for unrestricted use under any environmental conditionsIncreased energy harvesting thanks to the MPPT algorithm which works at the level of each solar panel in any light conditionNo DC input current rippleThe HF isolation allows it to fit any application that requires the grounding of either one of the input terminations95.5% of efficiencyEase of installation by the implementation of a package inclusive of proprietary wireless communication hub and grid interfaceReduced susceptibility to fault. In case of a component failure only the energy produced from one PV module will be lostUp to 10 micro inverters directly connectable in a string

•••

••

••

The new Aurora 300 Watt micro-inverter product off ers something new to Power-One customers. The ability to individually link all modules within a specific installation is an alternative to the traditional Aurora string inverters Power-One is famous for.

Micro-inverters have some advantages over string inverters. They allow you to control the panels output individually and off er Maximum Power Point Tracking (MPPT) for each single module.

They also allow you to control individual panels in diff erent ways and reduce the losses in efficiency in a variety of challenging conditions.

MICR

OOP

TIMIZE

R

Page 14: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

14 AURORA MICRO

BLOCK DIAGRAM OF MICROINVERTER

IN1

+

-

MPPT 1(DC/DC) BULK CAPS

INVERTER(DC/AC)

EMIOUTPUT

FILTER

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

L1(1)

L2(1)

HFTRANSFORMER

EMIOUTPUT

FILTER

L1(2)

N2

WIRELESS

PE

N1

L2(2)

MICRO-0.3-I MICRO-0.3-I

25

35

40

45

50

55

5% 10% 20% 30% 50% 75% 100%

Vin

[V]

E�ciency [%]

Pout [% @300W]

96-97 95-96 94-95 93-94 92-93 91-92 90-91 89-90 88-89 87-88 86-87 85-86 84-85 83-84 82-83 81-82 80-81 79-80 78-79 77-78 76-77 75-76 74-75

90

91

92

93

94

95

96

97

E�ci

necy

[%]

Pout [%@300W]

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

Vin=35V

Vin=40V

Vin=25V

Page 15: Renewable Energy Solutios

15AURORA MICRO

PARAMETER MICRO-0.25-I-OUTD

MICRO-0.3-I-OUTD

MICRO-0.25-I-OUTD-US

MICRO-0.3-I-OUTD-US

Input Side

Maximum DC Input Power (Pdcmax) 265 Wp 320 Wp 265 Wp 320 Wp

Operating DC Input Voltage Range (Vdcmin...Vdcmax) 18...58 V 18...58 V 18...58 V 18...58 V

MPPT Input DC Voltage Range (VMPPTmin ... VMPPTmax) 20...50 V 30...50 V 20...50 V 30...50 V

Absolute Maximum DC Input Voltage (Vmax,abs) 65 V 65 V 65 V 65 V

Maximum DC Input Current (Idcmax) 10.0 A 10.0 A 10.0 A 10.0 A

Number of DC Inputs Pairs for each MPPT 1 1 1 1

DC Connection Type Tool Free PV connector WM / MC4

Tool Free PV connector WM / MC4

Tool Free PV connector WM / MC4

Tool Free PV connector WM / MC4

Start-up DC Input Voltage (Vstart) 25V 25V 25V 25V

Output Side

AC Grid Connection Type Single phase Single phase Single phase/Split phase Single phase/Split phase

Rated AC Power (Pac,r) 250 W 300 W 250 W 300 W

Rated AC Grid Voltage (Vac,r) 230 V 230 V 208 V / 240 V 208 V / 240 V

AC Voltage Range (Vacmin...Vacmax) 180...264 V (1) 180...264 V (1) 183-228 V / 211-264 V 183-228 V / 211-264 V

Maximum AC Output Current (Iac,max) 1.2 A 1.5 A 1.3 A 1.15 A

Rated Output Frequency (fr) 50 Hz 50 Hz 60 Hz 60 Hz

Output Frequency Range (fmin...fmax) 47...53 Hz (2) 47...53 Hz (2) 59.3...60.5 Hz 59.3...60.5 Hz

Nominal Power Factor (Cosphiac,r) > 0.95 > 0.95 > 0.95 > 0.95

Maximum number of units per string 10 10 10 10

Output Protection

Anti-Islanding Protection According to local standard According to local standard According to local standard According to local standard

Output Overvoltage Protection - Varistor Yes Yes Yes Yes

Operating Performance

Maximum Efficiency (ηmax) 96.0% 96.3% 96.0% 96.3%

Weighted Efficiency (ηEURO/ηCEC) 95.4% / 95.5% 95.5% / 95.5% 95.4% / 95.5% 95.5% / 95.5%

Stand-by Consumption < 50mW < 50mW < 50mW < 50mW

Communication

Monitoring System (PC/Data logger) Wireless Wireless Wireless Wireless

Remote Monitoring Wireless Wireless Wireless Wireless

Environmental

Ambient Temperature Range -40...+85°C / -40...185°F with derating above 65°C/149°F

-40...+85°C / -40...185°F with derating above 65°C/149°F

-40...+85°C / -40...185°F with derating above 65°C/149°F

-40...+85°C / -40...185°F with derating above 65°C/149°F

Relative Humidity 0...100 % condensing 0...100 % condensing 0...100 % condensing 0...100 % condensing

Noise Emission < 30 db(A) @ 1 m < 30 db(A) @ 1 m < 30 db(A) @ 1 m < 30 db(A) @ 1 m

Maximum Operating Altitude without Derating 2000 m / 6560 ft 2000 m / 6560 ft 2000 m / 6560 ft 2000 m / 6560 ft

Physical

Environmental Protection Rating IP 65 IP 65 NEMA 4X NEMA 4X

Cooling Natural Natural Natural Natural

Dimension (H x W x D) 262mm x 244mm x 35mm / 10.3” x 9.6” x 1.37”

262mm x 244mm x 35mm / 10.3” x 9.6” x 1.37”

262mm x 244mm x 35mm / 10.3” x 9.6” x 1.37”

262mm x 244mm x 35mm / 10.3” x 9.6” x 1.37”

Weight < 1.65 kg / 3.5 lb < 1.65 kg / 3.5 lb < 1.65 kg / 3.5 lb < 1.65 kg / 3.5 lb

Safety

Isolation Level HF Transformer HF Transformer HF Transformer HF Transformer

Marking CE CE cCSAus cCSAus

Safety and EMC StandardEN61000-6-2, EN61000-6-3, EN61000-3-11, EN61000-3-

12, EN 50178

EN61000-6-2, EN61000-6-3, EN61000-3-11, EN61000-3-

12, EN 50178

EN 61000-6-2, EN 61000-6-3, FCC Part15 Class B, UL 1741

EN 61000-6-2, EN 61000-6-3, FCC Part15 Class B, UL 1741

Grid Standard VDE0126-1-1, DK5940, AS4777, G83/1

VDE0126-1-1, DK5940, AS4777, G83/1 IEEE 1547 IEEE 1547

Available Products Variants

Standard MICRO-0.25-I-OUTD-230 MICRO-0.3-I-OUTD-230 MICRO-0.25-I-OUTD-US-208/240

MICRO-0.3-I-OUTD-US-208/240

1. The AC voltage range may vary depending on specific country grid standard

2.The Frequency range may vary depending on specific country grid standard

Page 16: Renewable Energy Solutios

16 AURORA OPTIMIZER

Page 17: Renewable Energy Solutios

MICR

OOP

TIMIZE

R

OPTIMIZER

17AURORA OPTIMIZER

Page 18: Renewable Energy Solutios

OPTI-0.3-TL

GENERAL SPECIFICATIONSOUTDOOR MODELS

OPTI-0.3-TL-OUTDOPTI-0.3-TL-OUTD-US

18 AURORA OPTIMIZER

NEW

Page 19: Renewable Energy Solutios

19AURORA OPTIMIZER

Features

Ability to mitigate PV panel mismatchHigh efficiency up to 99.5%Single panel MPP tracker compatible with all Power-One inverter modelsEase of installation by the implementation of a package inclusive of proprietary wireless data communicationTemperature hardened construction

••••

Power-One’s new Optimizer products use DC-to-DC technology to help maximize the energy harvested from solar installations.

Normally, within each array, the solar panels are usually joined together in a serial pattern. This creates issues if one panel fails as this reduces the energy being produced by the entire installation. The Optimizer maximizes the energy from each module within a string as they ‘optimize’ the voltage/current for any given weather conditions.

The Optimizer also maximizes energy harvesting in panels suff ering from partial or temporary shading. This helps installers to create the largest installations possible andincrease Return on Investment (ROI).

MICR

OOP

TIMIZE

R

Page 20: Renewable Energy Solutios

Block Diagram

20 AURORA OPTIMIZER

BLOCK DIAGRAM OF OPTIMIZER WITH EXAMPLE OF CONFIGURATION

BLOCK DIAGRAM OF WIRELESS CONNECTION ARCHITECTURE

C

MPPT

WIRELESS

OPTI 0.3

MPPT

WIRELESS

OPTI 0.3

MPPT

WIRELESS

OPTI 0.3

MPPT

WIRELESS

OPTI 0.3

MPPT

WIRELESS

OPTI 0.3

MPPT

WIRELESS

OPTI 0.3

MPPT

WIRELESS

OPTI 0.3

MPPT

WIRELESS

OPTI 0.3

MPPT

WIRELESS

OPTI 0.3

MPPT

WIRELESS

OPTI 0.3

MPPT

WIRELESS

OPTI 0.3

MPPT

WIRELESS

OPTI 0.3

CSTRING COMBINER INVERTER

OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3* OPTI-0.3*

CDD#1(CONCENTRATOR DATA DEVICE)

CG(COMMUNICATION GATEWAY)

CDD#2(CONCENTRATOR DATA DEVICE)

CDD#N(CONCENTRATOR DATA DEVICE)

* EDD (END MODE DATA DEVICE)

INTERNET

Page 21: Renewable Energy Solutios

21AURORA OPTIMIZER

PARAMETER OPTI-0.3-TL-OUTD OPTI-0.3-TL-OUTD-US

Input Side

Maximum Input Power (Pdcmax) 300 Wp 300 Wp

MPP Input range (VMPPTmin-VMPPTmax) 20...60 V 20...60 V

Absolute Maximum Input Voltage (Vmax,abs) 65 V 65 V

Maximum Input Current (Idcmax) 10.0A 10.0A

Number of DC Inputs Pairs 1 1

DC Connection Type Tool Free PV connector WM / MC4 Tool Free PV connector WM / MC4

Maximum Output Power (Pdcmax) 300W 300W

Output Voltage Range (Vdcmin…Vdcmax) 20..60(1) V 20..60(1) V

Maximum Output Current (Idcmax) 12.0 A 12.0 A

Output Reverse Polarity Protection Yes Yes

Output Over Voltage Protection > 60 V > 60 V

Operating Performance

Maximum Efficiency (ηmax) 98.0 % 98.0 %

Pass Through Efficiency (ηpt) 99.3% 99.3%

Weighted Efficiency (ηEURO/ηCEC) 98.2% / 98.0% 98.2% / 98.0%

Communication

Remote Control (Data logger; On/Off; Upgrade) Wireless Wireless

User Interface Not applicable Not applicable

Environmental

Ambient Temperature Range -40...+65°C / -40...169°F -40...+65°C / -40...169°F

Relative Humidity 0...100% condensing 0...100% condensing

Noise Emission < 30 db(A) @ 1 m < 30 db(A) @ 1 m

Operating Altitude 2000 m / 6560 ft 2000 m / 6560 ft

Physical

Environmental Protection Rating IP 65 NEMA 4X

Cooling Natural Natural

Dimension (H x W x D) 158mm x 169mm x 28.6mm / 6.2” x 6.65” x 1.12” 158mm x 169mm x 28.6mm / 6.2” x 6.65” x 1.12”

Weight < 0,6 kg / 1,32 lb < 0,6 kg / 1,32 lb

Safety

Marking CE cCSAus

Safety and EMC Standard EN 61000-6-2, EN 61000-6-3, FCC Part15 Class B, EN 50178

EN 61000-6-2, EN 61000-6-3, FCC Part15 Class B, UL 1741

Available Products Variants

Standard OPTI-0.3-TL-OUTD OPTI-0.3-TL-OUTD-US

1. Adjustable via wireless connection

Page 22: Renewable Energy Solutios

22 AURORA UNO

Page 23: Renewable Energy Solutios

UNO

TRIO

UNO

23AURORA UNO

Page 24: Renewable Energy Solutios

PVI-2000PVI-3600

GENERAL SPECIFICATIONSINDOOR MODELS

PVI-2000PVI-3600

24 AURORA UNO

Page 25: Renewable Energy Solutios

Features

25AURORA UNO

Wide input rangeHigh speed and precise MPPT algorithm for real time power tracking and improved energy harvestingFlat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power rangeRS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP

••

••

The smallest of Power-One’s Aurora PV string inverters, this unit is designed to be housed indoors as opposed to many of its outdoor counterparts.

This small residential string inverter will work most eff ectively with small photovoltaic residential installations. This very compact, slim, lightweight and easy-to-install inverter off ers a very cost eff ective entry point for users new to photovoltaics or in need of a simple power inverter solution.

The inverter off ers a range of benefits, including maximum energy harvesting, through both its high-speed Maximum Power Point Tracker (MPPT) and transformerless technology. The important parameter is the wide input voltage range making the inverter suitable to low power installations with reduced string size. The graphical display allows users to check real-time performance through its integrated data logger.

UNO

TRIO

Page 26: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

26 AURORA UNO

PVI-2000 PVI-3600

85

87

89

91

93

95

97

99

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

220 Vdc

380 Vdc

480 Vdc

85

87

89

91

93

95

97

99

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

200 Vdc

380 Vdc

480 Vdc

BLOCK DIAGRAM OF PVI-2000 AND PVI-3600

IN1.1(+)

IN1.2(+)*

IN1.1(-)

IN1.2(-)*

IN

+

-

STANDARD VERSION

IN

+

-

MPPT (DC/DC) BULK CAPS

INVERTER(DC/AC)

LINEFILTER

GRID PARALLELRELAY

L

N

PE

RESIDUAL CURRENTDETECTION

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

(*) Not available for PVI-2000

Page 27: Renewable Energy Solutios

27AURORA UNO

PARAMETER PVI-2000 PVI-3600

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 600 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...580 VRated DC Input Power (Pdcr) 2100 W 3800 WNumber of Independent MPPT 1 2

Maximum DC Input Power for each MPPT (PMPPTmax)2100 W

Linear Derating From MAX to Null [530V≤VMPPT≤580V]

2000 W

MPPT Input DC Voltage Range (VMPPTmin,f ... VMPPTmax,f) at Pacr 210...530 V 200...530 VDC Input Voltage Range with Parallel Configuration of MPPT at Pacr Not applicable 200...530 V

DC Power Limitation with Parallel Configuration of MPPT Not applicable Linear Derating From MAX to Null [530V≤VMPPT≤580V]

DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Not applicable

2000 W [200V≤VMPPT≤530V] the other channel: Pdcr-2000W

[180V≤VMPPT≤530V]Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 10.0 A / 10.0 A 20.0 A / 10.0 AMaximum Input Short Circuit Current for each MPPT 12.0 ANumber of DC Inputs Pairs for each MPPT 1 2DC Connection Type Tool Free PV Connector WM / MC 3 / MC 4 (1)

Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2 2 for each MPPTPhotovoltaic Array Isolation Control According to local standardOutput SideAC Grid Connection Type Single phaseRated AC Power (Pacr) 2000 W 3600 WMaximum AC Output Power (Pacmax) 2000 W 3600 WRated AC Grid Voltage (Vac,r) 230 VAC Voltage Range 180...264 V (2)

Maximum AC Output Current (Iac,max) 10.0 A 16.0 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (3)

Nominal Power Factor (Cosphiac,r) > 0.995 Total Current Harmonic Distortion < 2.5 %AC Connection Type Circular connectorOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 16.0 A 20.0 AOutput Overvoltage Protection - Varistor 2 (L - N / L - PE)Operating PerformanceMaximum Efficiency (ηmax) 95.5% 96.0%Weighted Efficiency (EURO/CEC) 94.4% / - 95.0% / -Feed In Power Threshold 10.0 WStand-by Consumption < 8.0 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface Graphic displayEnvironmentalAmbient Temperature Range -20...+55°C /-4...131°F with derating above 40°C/104°FRelative Humidity 0...95 %Noise Emission < 30 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 21Cooling Air ForcedDimension (H x W x D) 440mm x 465mm x 57mm / 17.3” x 18.3” x 2.2”Weight < 7.5 kg / 16.5 lb < 8.5 kg / 18.7 lb Mounting System Wall bracketSafetyIsolation Level TransformerlessMarking CESafety and EMC Standard EN 50178, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3, AS/NZS 3100Grid Standard DK 5940, VDE 0126-1-1, G83/1, AS 4777Available Products VariantsStandard PVI-2000 PVI-3600

1. Different DC connection type for specific country model

2. The AC voltage range may vary depending on specific country grid standard

3. The Frequency range may vary depending on specific country grid standard

Page 28: Renewable Energy Solutios

UNO-2.0-IUNO-2.5-I

GENERAL SPECIFICATIONSOUTDOOR MODELS

UNO-2.0-I-OUTDUNO-2.5-I-OUTD

28 AURORA UNO

NEWNEWNEW

Page 29: Renewable Energy Solutios

Features

29AURORA UNO

Each inverter is set on specific grid codes which can be selected in the fieldSingle phase outputWide input rangeHigh speed and precise MPPT algorithm for real time power tracking and improved energy harvestingFlat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power rangeOutdoor enclosure for unrestricted use under any environmental conditionsRS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP

••••

•••

The UNO-2.0-I and UNO-2.5-I are the latest single phase string inverters in the Aurora range. A new-look inverter but packed with Power-One’s proven high performing technology. The new look inverter has new features including a special built-in heat sink compartment and front panel display system.

The smallest of Power-One’s outdoor range, these new products are the right size for the average rooftop installation. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.

The high speed MPPT off ers real-time power tracking and improved energy harvesting.

Despite the isolated operation, the UNO-2.0-I and UNO-2.5-I feature an efficiency of 96.3%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size.

UNO

TRIO

Page 30: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

30 AURORA UNO

UNO-2.0-I-OUTD UNO-2.5-I-OUTD

BLOCK DIAGRAM OF UNO-2.0-I AND UNO-2.5-I

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN

+

-

MPPT(DC/DC)

HFTRANSFORMER BULK CAPS

INVERTER(DC/AC)

LINEFILTER

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

GRID PARALLELRELAY

IN1

+

-

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

STANDARD VERSION

IN

+

-

-S VERSION

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

- L

- N

- PE

90,00%

91,00%

92,00%

93,00%

94,00%

95,00%

96,00%

97,00%

98,00%

99,00%

200Vdc

300Vdc

350Vdc

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

90,00%

91,00%

92,00%

93,00%

94,00%

95,00%

96,00%

97,00%

98,00%

99,00%

200Vdc

300Vdc

350Vdc

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

Page 31: Renewable Energy Solutios

31AURORA UNO

PARAMETER UNO-2.0-I-OUTD UNO-2.5-I-OUTD

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 520 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...520 VRated DC Input Power (Pdcr) 2100 W 2600 WNumber of Independent MPPT 1

Maximum DC Input Power for each MPPT (PMPPTmax)“2300 W

Linear Derating From MAX to Null [470V≤VMPPT≤520V]”

“2900 WLinear Derating From MAX to Null

[470V≤VMPPT≤520V]”MPPT Input DC Voltage Range (VMPPTmin,f ... VMPPTmax,f) at Pacr 200...470 V 205...470 VDC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Not applicable

Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 10.0 A / 10.0 A 12.8 A / 12.8 AMaximum Input Short Circuit Current for each MPPT 15.0 ANumber of DC Inputs Pairs for each MPPT 2DC Connection Type Tool Free PV Connector WM / MC4 Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control According to local standardDC Switch Rating for each MPPT (-S Version) 16 A / 600 VOutput SideAC Grid Connection Type Single phaseRated AC Power (Pacr) 2000 W 2500 WMaximum AC Output Power (Pacmax) 2200 W 2750 WRated AC Grid Voltage (Vac,r) 230 VAC Voltage Range 180...264 V (1)

Maximum AC Output Current (Iac,max) 10.0 A 12.0 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (2)

Nominal Power Factor (Cosphiac,r) > 0.995 (adj. ± 0.95)Total Current Harmonic Distortion < 2%AC Connection Type Screw terminal blockOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 15.0 AOutput Overvoltage Protection - Varistor 2 (L - N / L - PE)Operating PerformanceMaximum Efficiency (ηmax) 96.3%Weighted Efficiency (EURO/CEC) 95.0% / - Feed In Power Threshold 24.0 WStand-by Consumption < 8.0 W (3)

CommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface Graphic display EnvironmentalAmbient Temperature Range -25...+60°C (-13...+ 140°F) with derating above 45°C (113°F)Relative Humidity 0...100 % condensingNoise Emission < 50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65Cooling NaturalDimension (H x W x D) 518mm x 367mm x 160mm / 20.4” x 14.4” x 6.3”Weight < 17 kg / 37.4 lbMounting System Wall bracketSafetyIsolation Level HF transformerMarking CESafety and EMC Standard EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-11, EN61000-3-12Grid Standard Enel Guideline, VDE 0126-1-1, G83/1, EN 50438, RD1663, AS 4777Available Products VariantsWith DC Switch UNO-2.0-I-OUTD-S UNO-2.5-I-OUTD-S

1. The AC voltage range may vary depending on specific country grid standard

2. The Frequency range may vary depending on specific country grid standard

3. Night time consumption < 0.6W

Page 32: Renewable Energy Solutios

PVI-2000 OUTD OLDProd1_Title

Prod1_Part NosProd1_Prod PicProd1_Back Pic

PVI-2000-OUTD

GENERAL SPECIFICATIONSOUTDOOR MODELS

PVI-2000-OUTD

Wide input rangeHigh speed and precise MPPT algorithm for real time power tracking and improved energy harvestingOutdoor enclosure for unrestricted use under any environmental conditionsRS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP

•••••

The transformerless operation of this compact outdoor residential inverter provides an efficiency of 95.5%. The high-speed Maximum Power Point Tracker (MPPT) produces real-time power tracking and improved energy harvesting.

The wide input voltage range makes this inverter suitable to low power installations with reduced string size. This rugged outdoor inverter has been designed as a completely sealed unit to stand withstand the harshest environmental conditions.

This small single string inverter features a front heat sink to keep the unit cleaner and more efficient over time.

Features

32 AURORA UNO

Page 33: Renewable Energy Solutios

33AURORA UNO 33AURORA UNO

PARAMETER PVI-2000-OUTD

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 600 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...580 VRated DC Input Power (Pdcr) 2100 WNumber of Independent MPPT 1

Maximum DC Input Power for each MPPT (PMPPTmax) 2100 W Linear Derating From MAX to Null [530V≤VMPPT≤580V]

MPPT Input DC Voltage Range (VMPPTmin,f ... VMPPTmax,f) at Pacr 210...530 VDC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example Not applicable

Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 10.0 A / 10.0 AMaximum Input Short Circuit Current for each MPPT 12.0 ANumber of DC Inputs Pairs for each MPPT 1DC Connection Type Tool Free PV Connector WM / MC4 Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control According to local standardOutput SideAC Grid Connection Type Single phaseRated AC Power (Pacr) 2000 WMaximum AC Output Power (Pacmax) 2000 WRated AC Grid Voltage (Vac,r) 230 VAC Voltage Range 180...264 V (1)

Maximum AC Output Current (Iac,max) 10.0 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (2)

Nominal Power Factor (Cosphiac,r) > 0.995 Total Current Harmonic Distortion < 2.5 %AC Connection Type Circular connectorOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 16.0 AOutput Overvoltage Protection - Varistor 2 (L - N / L - PE)Operating PerformanceMaximum Efficiency (ηmax) 95.5% Weighted Efficiency (EURO/CEC) 94.4% / -Feed In Power Threshold 10.0 WStand-by Consumption < 8.0 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+60°C /-13...140°F with derating above 40°C/104°FRelative Humidity 0...100 % condensingNoise Emission < 40 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65Cooling NaturalDimension (H x W x D) 420mm x 326mm x 141mm / 16.5” x 12.8” x 5.6”Weight < 14.5 kg / 32.0 lbMounting System Wall bracketSafetyIsolation Level TransformerlessMarking CESafety and EMC Standard EN 50178, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3, AS/NZS 3100Grid Standard DK 5940, VDE 0126-1-1, G83/1, AS 4777Available Products VariantsStandard PVI-2000-OUTD

1. The AC voltage range may vary depending on specific country grid standard

2. The Frequency range may vary depending on specific country grid standard

Page 34: Renewable Energy Solutios

PVI-3.0-TLPVI-3.6-TLPVI-4.2-TL

GENERAL SPECIFICATIONSOUTDOOR MODELS

PVI-3.0-TL-OUTDPVI-3.0-OUTD-US

PVI-3.6-TL-OUTDPVI-3.6-OUTD-US

PVI-4.2-TL-OUTDPVI-4.2-OUTD-US

34 AURORA UNO

Europe and APAC Version

North America Version

Page 35: Renewable Energy Solutios

Each inverter is set on specific grid codes which can be selected in the fieldSingle phase outputDual input sections with independent MPP tracking, allows optimal energy harvesting from two sub-arrays oriented in diff erent directionsWide input rangeHigh speed and precise MPPT algorithm for real time power tracking and improved energy harvestingFlat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power rangeOutdoor enclosure for unrestricted use under any environmental conditionsIntegrated DC disconnect switch in compliance with international Standards (-S Version)RS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP

•••

••

••••

The most common residential inverter is the ideal size for an average-sized family home. This family of single-phase string inverter complements the typical number of rooftop solar panels, allowing home-owners to get the most efficient energy harvesting for the size of the property. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.

One of the key benefits of the Uno family of single-phase inverters is the dual input section to process two strings with independent MPPT especially useful for rooftop installations with two diff erent orientations (ie East and West). The high speed MPPT off ers real-time power tracking and improved energy harvesting.

The transformerless operation gives the highest efficiency of up to 97.0%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size.

Features

35AURORA UNO

UNO

TRIO

Page 36: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

36 AURORA UNO

BLOCK DIAGRAM OF PVI-3.0-TL-OUTD, PVI-3.6-TL-OUTD AND PVI-4.2-TL-OUTD

PVI-4.2-TL-OUTD PVI-4.2-TL-OUTD

5,00% 10,00% 15,00% 20,00% 25,00% 30,00% 35,00% 40,00% 45,00% 50,00% 55,00% 60,00% 65,00% 70,00% 75,00% 80,00% 85,00% 90,00% 95,00% 100,00%

215 250 300 345 400 480

[%] o

f Rat

ed P

ower

MPPT Voltage [V]

96,8

96,4

96

94,8

94,4

95,2

94

93,6

93,2

92,8

92,4

92

91,6

95,6

96,8

96,4

96,4

96

95,2

96

95,2

96,2

96

94 94

92 92 92

85

86

87

88

89

90

91

92

93

94

95

96

97

98

99

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

[%]

% of rated Output Power

215Vdc

345Vdc

480Vdc

IN1.1(+)

IN1.2(+)*

IN1.1(-)

IN1.2(-)*

IN2.1(+)

IN2.1(-)

IN1.1(+)

IN1.2(+)*

IN1.1(-)

IN1.2(-)*

IN1

IN2

+

-

+

-

IN2.1(+)

IN2.1(-)

STANDARD VERSION

IN1

IN2

+

-

+

-

-S VERSION

IN1

+

-

MPPT 1(DC/DC)

IN2

+

-

MPPT 2(DC/DC)

BULK CAPSINVERTER(DC/AC)

LINEFILTER

GRID PARALLELRELAY

L

N

PE

RESIDUAL CURRENTDETECTION

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

(*)Not available in PVI-3.0-TL-OUTD

Page 37: Renewable Energy Solutios

37AURORA UNO

PARAMETER PVI-3.0-TL-OUTD PVI-3.6-TL-OUTD PVI-4.2-TL-OUTD

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 600 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...580 VRated DC Input Power (Pdcr) 3120 W 3750 W 4375 WNumber of Independent MPPT 2Maximum DC Input Power for each MPPT (PMPPTmax) 2000 W 3000 WDC Input Voltage Range with Parallel Configuration of MPPT at Pacr 160...530 V 120...530 V 140...530 VDC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [530V≤VMPPT≤580V]

DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example

2000 W [200V≤VMPPT≤530V] the other channel: Pdcr-2000W

[112V≤VMPPT≤530V]

3000 W [190V≤VMPPT≤530V] the other channel: Pdcr-3000W [90V≤VMPPT≤530V]

Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 20.0 A / 10.0 A 32.0 A / 16.0 AMaximum Input Short Circuit Current for each MPPT 12.5 A 20.0 ANumber of DC Inputs Pairs for each MPPT 1 2 for MPPT1 and 1 for MPPT2DC Connection Type Tool Free PV Connector WM / MC4 Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control According to local standardDC Switch Rating for each MPPT (-S Version) 25 A / 600 VOutput SideAC Grid Connection Type Single phaseRated AC Power (Pacr) 3000 W 3600 W 4200 WMaximum AC Output Power (Pacmax) 3300 W 4000 W 4600 WRated AC Grid Voltage (Vac,r) 230 VAC Voltage Range 180...264 V(1)

Maximum AC Output Current (Iac,max) 14.5 A 17.2 A (2) 20.0 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (3)

Nominal Power Factor (Cosphiac,r) > 0.995 Total Current Harmonic Distortion < 3.5 % AC Connection Type Screw terminal blockOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 16.0 A 19.0 A 22.0 AOutput Overvoltage Protection - Varistor 2 (L - N / L - PE)Operating PerformanceMaximum Efficiency (ηmax) 96.8% Weighted Efficiency (EURO/CEC) 96.0% / -Feed In Power Threshold 10.0 WStand-by Consumption < 8.0 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+60°C /-13...140°F with derating above 55°C/131°FRelative Humidity 0...100 % condensingNoise Emission < 50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65Cooling NaturalDimension (H x W x D) 617mm x 325mm x 222mm / 24.3” x 12.8” x 8.7”Weight 17.5 kg / 38.5 lbMounting System Wall bracketSafetyIsolation Level TransformerlessMarking CESafety and EMC Standard EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3

Grid Standard DK 5940, VDE 0126-1-1, G83/1, EN 50438, RD1663, AS 4777

DK 5940, VDE 0126-1-1, G83/1, G59/2(4) , EN 50438, RD1663,

AS 4777

DK 5940, VDE 0126-1-1, G59/2, EN 50438, RD1663, AS 4777

Available Products VariantsStandard PVI-3.0-TL-OUTD PVI-3.6-TL-OUTD PVI-4.2-TL-OUTDWith DC Switch PVI-3.0-TL-OUTD-S PVI-3.6-TL-OUTD-S PVI-4.2-TL-OUTD-S1. The AC voltage range may vary depending on specific country grid standard2. Maximum Output Current Limited to 16A for G83/1 version3. The Frequency range may vary depending on specific country grid standard4. Ask sales for availability

Page 38: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

38 AURORA UNO

5,00%

10,00%

15,00%

20,00%

25,00%

30,00%

35,00%

40,00%

45,00%

50,00%

55,00%

60,00%

65,00%

70,00%

75,00%

80,00%

85,00%

90,00%

95,00%

100,00%

215 250 300 345 400 480

[%] o

f Rat

ed P

ower

MPPT Voltage [V]

97,0

96,6

96

94,8

94,4

95,2

94

93,6

93,2

92,8

92,4

92

91,6

95,6

97,0

96,4

96,4

96

95,2

96

95,2

96,2

96

94 94

92 92

92 90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

200 Vdc

340 Vdc

480 Vdc

PVI-4.2-OUTD-US PVI-4.2-OUTD-US

BLOCK DIAGRAM OF PVI-3.0-OUTD, PVI-3.6-OUTD AND PVI-4.2-OUTD FOR NORTH AMERICA

IN1

+

-

IN2

+

-

MPPT 2(DC/DC)

MPPT 1(DC/DC) BULK CAPS

INVERTER(DC/AC)

LINEFILTER

GRID PARALLELRELAY

L1

L2

PE

RESIDUAL CURRENTDETECTION

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

IN1

IN2

+

-

+

-

GROUNDFAULT

DETECTION

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1

IN2

+

-

+

-

IN2.1(+)

IN2.2(+)

IN2.1(-)

IN2.2(-)

STANDARD VERSION -S VERSION

N

IN1.1(+)

IN1.1(-)

IN2.1(+)

IN2.1(-)

Page 39: Renewable Energy Solutios

39AURORA UNO

PARAMETER PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-4.2-OUTD-US

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 600 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...580 VRated DC Input Power (Pdcr) 3120 W 3750 W 4380 WNumber of Independent MPPT 2Maximum DC Input Power for each MPPT (PMPPTmax) 2000 W 3000 WDC Input Voltage Range with Parallel Configuration of MPPT at Pacr 160...530 V 120...530 V 140...530 VDC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [530V≤VMPPT≤580V]

DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example

2000 W [200V≤VMPPT≤530V] the other channel: Pdcr-2000W

[112V≤VMPPT≤530V]

3000 W [190V≤VMPPT≤530V] the other channel: Pdcr-3000W [90V≤VMPPT≤530V]

Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 20.0 A / 10.0 A 32.0 A / 16.0 AMaximum Input Short Circuit Current for each MPPT 12.5 A 20.0 ANumber of DC Inputs Pairs for each MPPT 2 (1 on -S Version)DC Connection Type Screw terminal block,3 Knock-Outs: 1 ½” or 1” (w/ Ring Red.)Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control GFDI (for use with either Positive or Negative Grounded Arrays)DC Switch Rating for each MPPT (-S Version) 25 A / 600 V Output Side 208 V 240 V 277 V 208 V 240 V 277 V 208 V 240 V 277 VAC Grid Connection Type Single phase / Split phaseRated AC Power (Pacr) 3000 W 3600 W 4200 WMaximum AC Output Power (Pacmax) 3000 W 3300 W 3300 W 3600W 4000 W 4000 W 4200 W 4600 W 4600 WRated AC Grid Voltage (Vac,r) 208 V 240 V 277 V 208 V 240 V 277 V 208 V 240 V 277 VAC Voltage Range 183-228 V 211-264 V 244-304 V 183-228 V 211-264 V 244-304 V 183-228 V 211-264 V 244-304 VMaximum AC Output Current (Iac,max) 14.5 A 14.5 A 12.0 A 17.2 A 16.0 A 16.0 A 20.0 A 20.0 A 20.0 ARated Output Frequency (fr) 60 HzOutput Frequency Range (fmin...fmax) 59.3...60.5 HzNominal Power Factor (Cosphiac,r) > 0.995 Total Current Harmonic Distortion < 2%AC Connection Type Screw Terminal Block, 3 Knock-Outs: 1 ½” or 1” (w/ Ring Reducer)Output Protection 208 V 240 V 277 V 208 V 240 V 277 V 208 V 240 V 277 VAnti-Islanding Protection According to UL 1741/IEE1547Maximum AC Overcurrent Protection 20.0 A 20.0 A 15.0 A 25.0 A 20.0 A 20.0 A 25.0 A 25.0 A 25.0 AOutput Overvoltage Protection - Varistor 2 (L1 - L2 / L1 - PE)Operating Performance 208 V 240 V 277 V 208 V 240 V 277 V 208 V 240 V 277 VMaximum Efficiency (ηmax) 96.9% 97.0% 97.0%Weighted Efficiency (EURO/CEC) - / 96.0% - / 96.0% - / 96.0% - / 96.0% - / 96.0% - / 96.0% - / 96.0% - / 96.0% - / 96.0%Feed In Power Threshold 20.0 WStand-by Consumption < 8.0 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+60°C (-13...+140°F) with derating above 55°C (131°F)Relative Humidity 0...100 % condensingNoise Emission < 50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating NEMA 4XCooling Natural

Dimension (H x W x D) 617mm x 325mm x 222mm / 24.3” x 12.8” x 8.7” 859mm x 325mm x 222mm / 33.8” x 12.8” x 8.7” (-S Version)

Weight < 17.5 kg / 38,5 lb < 21.3 kg / 47.3 lb (-S version)

Mounting System Wall bracketSafetyIsolation Level TransformerlessMarking cCSAusSafety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01Grid Standard IEEE 1547Available Products VariantsStandard PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-4.2-OUTD-USWith DC Switch PVI-3.0-OUTD-S-US PVI-3.6-OUTD-S-US PVI-4.2-OUTD-S-US

Page 40: Renewable Energy Solutios

Europe and APAC Version

North America Version

PVI-3.8-IPVI-4.6-I

GENERAL SPECIFICATIONSOUTDOOR MODELS

PVI-3.8-I-OUTDPVI-3.8-I-OUTD-US

PVI-4.6-I-OUTDPVI-4.6-I-OUTD-US

40 AURORA UNO

Page 41: Renewable Energy Solutios

Features

Each inverter is set on specific grid codes which can be selected in the fieldSingle phase outputNight Wake up button to access energy harvesting data and error logDual input sections with independent MPP tracking, allows optimal energy harvesting from two sub-arrays oriented in diff erent directionsWide input rangeHigh speed and precise MPPT algorithm for real time power tracking and improved energy harvestingFlat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power rangeOutdoor enclosure for unrestricted use under any environmental conditionsRS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP

••••

••

•••

This isolated inverter is optimized for use in residential applications requiring PV array groun-ding, such as some thin-film modules. This inverter has also been designed to serve all countries and regions with specific field-configurable set-ups available for all major country grid codes and display languages.

The 3.8 and 4.6kW isolated inverters have all the usual Aurora benefits including dual input section to process two strings with independent MPPT, high speed and precise MPPT algorithm for real-time power tracking and energy harvesting, as well as regular high performance efficiencies of up to 96.9%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size.

Its high frequency isolated topology allows this unit to be lightweight and compact in size to help with transportation and installation. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.

41AURORA UNO

UNO

TRIO

Page 42: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

42 AURORA UNO

PVI-3.8-I-OUTD PVI-4.6-I-OUTD

BLOCK DIAGRAM OF PVI-3.8-I-OUTD AND PVI-4.6-I-OUTD

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN2.1(+)

IN2.2(+)

IN2.1(-)

IN2.2(-)

RS485

ALARM

IN1

+

-

MPPT 1(DC/DC)

IN2

+

-

MPPT 2(DC/DC)

BULK CAPSINVERTER(DC/AC)

LINEFILTER

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

GRID PARALLELRELAY

L

N

PE

HFTRANSFORMER

HFTRANSFORMER

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1

IN2

+

-

+

-

IN2.1(+)

IN2.2(+)

IN2.1(-)

IN2.2(-)

STANDARD VERSION

IN1

IN2

+

-

+

-

-S VERSION

+ T/R

- T/R

RTN

+ R

- R

N.C

N.O

C

REMOTE CONTROL

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

200 Vdc

340 Vdc

416 Vdc

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

200 Vdc

340 Vdc

416 Vdc

Page 43: Renewable Energy Solutios

43AURORA UNO

PARAMETER PVI-3.8-I-OUTD PVI-4.6-I-OUTD

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 520 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...520 VRated DC Input Power (Pdcr) 4000 W 4800 WNumber of Independent MPPT (4) 2Maximum DC Input Power for each MPPT (PMPPTmax) 3000 WDC Input Voltage Range with Parallel Configuration of MPPT at Pacr 160...470 V 180...470 V

DC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [470V≤VMPPT≤520V]

Linear Derating From MAX to Null [470V≤VMPPT≤520V]

DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example

3000 W [210V≤VMPPT≤470V] the other channel: Pdcr-3000W [90V≤VMPPT≤470V]

3000 W [210V≤VMPPT≤470V] the other channel: Pdcr-3000W [130V≤VMPPT≤470V]

Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 25.0 A / 12.5 A 28.0 A / 14.0 AMaximum Input Short Circuit Current for each MPPT 22.0 ANumber of DC Inputs Pairs for each MPPT 2DC Connection Type Tool Free PV Connector WM / MC4 Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control According to local standardDC Switch Rating for each MPPT (-S Version) 25 A / 600 V Output SideAC Grid Connection Type Single phaseRated AC Power (Pacr) 3800 W 4600 WMaximum AC Output Power (Pacmax) 4200 W 5000 WRated AC Grid Voltage (Vac,r) 230 VAC Voltage Range 180...264 V (1)

Maximum AC Output Current (Iac,max) 18.2 A (2) 22.5 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (3)

Nominal Power Factor (Cosphiac,r) > 0.995 (adj. ± 0.95)Total Current Harmonic Distortion < 2%AC Connection Type Screw terminal blockOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 20.0 A 25.0 AOutput Overvoltage Protection - Varistor 2 (L - N / L - PE)Operating PerformanceMaximum Efficiency (ηmax) 96.8%Weighted Efficiency (EURO/CEC) - / 96.5% Feed In Power Threshold 24.0 WStand-by Consumption < 8.0 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmental

Ambient Temperature Range -25...+60°C (-13...+ 140°F) -25...+60°C (-13...+ 140°F)with derating above 50°C (122°F)

Relative Humidity 0...100 % condensingNoise Emission < 50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65Cooling NaturalDimension (H x W x D) 712mm x 325mm x 222mm / 28.0” x 12.8” x 8.7”Weight < 24.0 kg / 53.0 lbMounting System Wall bracketSafetyIsolation Level HF TransformerMarking CESafety and EMC Standard EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-11, EN61000-3-12Grid Standard Enel Guideline, VDE 0126-1-1, G83/1, G59/2, EN 50438, RD1663, AS 4777Available Products VariantsStandard PVI-3.8-I-OUTD PVI-4.6-I-OUTDWith DC Switch PVI-3.8-I-OUTD-S PVI-4.6-I-OUTD-S

1. The AC voltage range may vary depending on specific country grid standard2. Maximum Output Current Limited to 16A for G83/1 version3. The Frequency range may vary depending on specific country grid standard4. Independent MPPT just with negative ground

Page 44: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

44 AURORA UNO

PVI-3.8-I-OUTD-US PVI-4.6-I-OUTD-US

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

200 Vdc

340 Vdc

416 Vdc

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

200 Vdc

340 Vdc

416 Vdc

BLOCK DIAGRAM OF PVI-3.8-I-OUTD AND PVI-4.6-I-OUTD FOR NORTH AMERICA

IN1

+

-

IN2

+

-

MPPT 2(DC/DC)

MPPT 1(DC/DC) BULK CAPS

INVERTER(DC/AC)

LINEFILTER

GRID PARALLELRELAY

L1

L2

PE

RESIDUAL CURRENTDETECTION

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

IN1

IN2

+

-

+

-

GROUNDFAULT

DETECTION

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1

IN2

+

-

+

-

IN2.1(+)

IN2.2(+)

IN2.1(-)

IN2.2(-)

STANDARD VERSION -S VERSION-NG

N

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN2.1(+)

IN2.2(+)

IN2.1(-)

IN2.2(-)

HFTRANSFORMER

HFTRANSFORMER

* if -PG version, switch is on negative polarity.

*

*

Page 45: Renewable Energy Solutios

45AURORA UNO

PARAMETER PVI-3.8-I-OUTD-US PVI-4.6-I-OUTD-US

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 520 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...520 VRated DC Input Power (Pdcr) 4000 W 4800 WNumber of Independent MPPT (4) 2Maximum DC Input Power for each MPPT (PMPPTmax) 3000 WDC Input Voltage Range with Parallel Configuration of MPPT at Pacr 200...470 V

DC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [470V≤VMPPT≤520V]

Linear Derating From MAX to Null [470V≤VMPPT≤520V]

DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example

3000 W [240V≤VMPPT≤470V] the other channel: Pdcr-3000W

[90V≤VMPPT≤470V]

3000 W [210V≤VMPPT≤470V] the other channel:

Pdcr-3000W [130V≤VMPPT≤470V]Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 25.0 A / 12.5 A 28.0 A / 14.0 AMaximum Input Short Circuit Current for each MPPT 15.6 A 17.0 ANumber of DC Inputs Pairs for each MPPT 2DC Connection Type Screw terminal block, 3 Knock-Outs: ¾” or 1” (w/ Ring Red.)Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control GFDI (for use with either Positive or Negative Grounded Arrays)DC Switch Rating for each MPPT (-S Version) 25 A / 600 V Output Side 208 V 240 V 277 V 208 V 240 V 277 VAC Grid Connection Type Single phase / Split phaseRated AC Power (Pacr) 3300 W 3800 W 4600 WMaximum AC Output Power (Pacmax) 3300 W 3800W 4200 W 5000 W 5000 W 5000 WRated AC Grid Voltage (Vac,r) 208 V 240 V 277 V 208 V 240 V 277 VAC Voltage Range 183...228 V 211...264 V 244...304 V 183...228 V 211...264 V 244...304 VMaximum AC Output Current (Iac,max) 16.0 A 16.0 A 16.0 A 23.0 A 20.0 A 20.0 A Rated Output Frequency (fr) 60 HzOutput Frequency Range (fmin...fmax) 59.3...60.5 HzNominal Power Factor (Cosphiac,r) > 0.995Total Current Harmonic Distortion < 2%AC Connection Type Screw terminal block, 3 Knock-Outs: ¾” or 1” (w/ Ring Red.)Output Protection 208 V 240 V 277 V 208 V 240 V 277 VAnti-Islanding Protection According to UL 1741/IEE1547Maximum AC Overcurrent Protection 20.0 A 20.0 A 20.0 A 30.0 A 25.0 A 25.0 AOutput Overvoltage Protection - Varistor 2 (L1 - L2 / L1 - PE)Operating Performance 208 V 240 V 277 V 208 V 240 V 277 VMaximum Efficiency (ηmax) 96.9% 96.9%Weighted Efficiency (EURO/CEC) - / 96.0% - / 96.5% - / 96.5% - / 96.0% - / 96.5% - / 96.5%Feed In Power Threshold 24.0 WStand-by Consumption < 8.0 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmental

Ambient Temperature Range -25...+60°C (-13...+ 140°F) -25...+60°C (-13...+ 140°F)with derating above 50°C (122°F)

Relative Humidity 0...100 % condensingNoise Emission < 50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating NEMA 4XCooling Natural

Dimension (H x W x D) 712mm x 325mm x 222mm / 28.0” x 12.8” x 8.7” 952mm x 325mm x 222mm / 37.5” x 12.8” x 8.7” (-S Version)

Weight < 24.0 kg / 53.0 lb < 28.0 kg / 61.0 lb (-S version)

Mounting System Wall bracketSafetyIsolation Level HF TransformerMarking cCSAusSafety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01Grid Standard IEEE 1547Available Products VariantsStandard - Positive Ground PVI-3.8-I-OUTD-US-PG PVI-4.6-I-OUTD-US-PGStandard - Negative Ground PVI-3.8-I-OUTD-US-NG PVI-4.6-I-OUTD-US-NGWith DC Switch - Positive Ground PVI-3.8-I-OUTD-US-S-PG PVI-4.6-I-OUTD-US-S-PGWith DC Switch - Negative Ground PVI-3.8-I-OUTD-US-S-NG PVI-4.6-I-OUTD-US-S-NG

4. Independent MPPT just with negative ground

Page 46: Renewable Energy Solutios

Europe and APAC Version

North America Version

PVI-5000-TLPVI-6000-TL

GENERAL SPECIFICATIONSOUTDOOR MODELS

PVI-5000-TL-OUTDPVI-6000-TL-OUTD

PVI-5000-OUTD-USPVI-6000-OUTD-US

46 AURORA UNO

Page 47: Renewable Energy Solutios

Features

Each inverter is set on specific grid codes which can be selected in the fieldSingle phase outputDual input sections with independent MPP tracking, allows optimal energy harvesting from two sub-arrays oriented in diff erent directionsWide input rangeHigh speed and precise MPPT algorithm for real time power tracking and improved energy harvestingFlat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power rangeOutdoor enclosure for unrestricted use under any environmental conditionsRS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP

•••

••

•••

Designed for residential and small commercial PV installations, this inverter fills a specific niche in the Aurora product line to cater for those installations producing between 5kW and 20kW.

This inverter has all the usual Aurora benefits, including dual input section to process two strings with independent MPPT, high speed and precise MPPT algorithm for real-time power tracking and energy harvesting, as well as transformerless operation for high performance efficiencies of up to 97.1%.

The wide input voltage range makes the inverter suitable to low power installations with reduced string size. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.

47AURORA UNO

UNO

TRIO

Page 48: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

48 AURORA UNO

BLOCK DIAGRAM OF PVI-5000-TL-OUTD AND PVI-6000-TL-OUTD

PVI-5000-TL-OUTD PVI-6000-TL-OUTD

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

250 Vdc

345 Vdc

480 Vdc

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

250 Vdc

345 Vdc

480 Vdc

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN2.1(+)

IN2.2(+)

IN2.1(-)

IN2.2(-)

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1

IN2

+

-

+

-

IN2.1(+)

IN2.2(+)

IN2.1(-)

IN2.2(-)

STANDARD VERSION

IN1

IN2

+

-

+

-

-S VERSION

IN1

+

-

MPPT 1(DC/DC)

IN2

+

-

MPPT 2(DC/DC)

BULK CAPSINVERTER(DC/AC)

LINEFILTER

GRID PARALLELRELAY

L

N

PE

RESIDUAL CURRENTDETECTION

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

Page 49: Renewable Energy Solutios

49AURORA UNO

PARAMETER PVI-5000-TL-OUTD PVI-6000-TL-OUTD

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 600 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...580 VRated DC Input Power (Pdcr) 4800 W 6200 WNumber of Independent MPPT 2Maximum DC Input Power for each MPPT (PMPPTmax) 4000 WDC Input Voltage Range with Parallel Configuration of MPPT at Pacr 150...530 V 180...530 VDC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [530V≤VMPPT≤580V]

DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example

4000 W [220V≤VMPPT≤530V] the other channel: Pdcr-4000W

[90V≤VMPPT≤530V]

4000 W [220V≤VMPPT≤530V] the other channel: Pdcr-4000W

[120V≤VMPPT≤530V] Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 36.0 A / 18.0 AMaximum Input Short Circuit Current for each MPPT 22.0 ANumber of DC Inputs Pairs for each MPPT 2DC Connection Type Tool Free PV Connector WM / MC4 Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control According to local standardDC Switch Rating for each MPPT (-S Version) 25 A / 600 V Output SideAC Grid Connection Type Single phaseRated AC Power (Pacr) 5000 W 6000 WMaximum AC Output Power (Pacmax) 5000 W (3) 6000 WRated AC Grid Voltage (Vac,r) 230 VAC Voltage Range 180...264 V (1)

Maximum AC Output Current (Iac,max) 25.0 A 30.0 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (2)

Nominal Power Factor (Cosphiac,r) > 0.995 Total Current Harmonic Distortion < 3.5%AC Connection Type Screw terminal blockOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 32.0 A 40.0 AOutput Overvoltage Protection - Varistor 2 (L - N / L - PE)Operating PerformanceMaximum Efficiency (ηmax) 97.0%Weighted Efficiency (EURO/CEC) 96.4% / -Feed In Power Threshold 10.0 WStand-by Consumption < 8.0 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+60°C (-13...+ 140°F) with derating above 50°C (122°F)Relative Humidity 0...100% condensingNoise Emission <50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65Cooling NaturalDimension (H x W x D) 810mm x 325mm x 222mmm / 31.9” x 12.8” x 8.7”Weight < 26.0 kg / 57.3 lb Mounting System Wall bracketSafetyIsolation Level TransformerlessMarking CESafety and EMC Standard EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3Grid Standard DK 5940, VDE 0126-1-1, G59/2, EN 50438, RD1663, AS 4777Available Products VariantsStandard PVI-5000-TL-OUTD PVI-6000-TL-OUTDWith DC Switch PVI-5000-TL-OUTD-S PVI-6000-TL-OUTD-S

1. The AC voltage range may vary depending on specific country grid standard

2. The Frequency range may vary depending on specific country grid standard

3. Limited to 4600 W for Germany

Page 50: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

50 AURORA UNO

PVI-6000-OUTD-US PVI-6000-OUTD-US

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

250 Vdc

345 Vdc

480 Vdc

250

300

345

400

480

10% 20% 30% 50% 75% 100%

96,8

96,5

96,2

95,9

95,6

95,3

95 94,7

94,4 94,1

93,8

93,5

93,2

92,9

92,6

97,1

97,1

96,8

96,5

96,2

95,9

96,5

96,2

95

[%] o

f Rat

ed P

ower

MPPT Voltage [V]

BLOCK DIAGRAM OF PVI-5000-OUTD AND PVI-6000-OUTD FOR NORTH AMERICA

IN1

+

-

MPPT 1(DC/DC)

IN2

+

-

MPPT 2(DC/DC)

BULK CAPSINVERTER(DC/AC)

LINEFILTER

GRID PARALLELRELAY

L1

L2

PE

RESIDUAL CURRENTDETECTION

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

IN1(+)

IN1(-)

IN1

IN2

+

-

+

-

IN2(+)

IN2(-)

GROUNDFAULT

DETECTION

-S VERSION

N

Page 51: Renewable Energy Solutios

51AURORA UNO

PARAMETER PVI-5000-OUTD-US PVI-6000-OUTD-US

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 600 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...580 VRated DC Input Power (Pdcr) 5150 W 6180 WNumber of Independent MPPT 2Maximum DC Input Power for each MPPT (PMPPTmax) 4000 WDC Input Voltage Range with Parallel Configuration of MPPT at Pacr 200...530 VDC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [530V≤VMPPT≤580V]

DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example

4000 W [225V≤VMPPT≤530V] the other channel: Pdcr-4000W

[90V≤VMPPT≤530V]

4000 W [230V≤VMPPT≤530V] the other channel: Pdcr-4000W

[120V≤VMPPT≤530V] Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 36.0 A / 18.0 AMaximum Input Short Circuit Current for each MPPT 22.0 ANumber of DC Inputs Pairs for each MPPT 1DC Connection Type Screw Terminal Block, 3 Knock-Outs: 1 ½” or 1” (w/ Ring Reducer)Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control GFDI (for use with either Positive or Negative Grounded Arrays)DC Switch Rating for each MPPT (-S Version) 25 A / 600 V Output Side 208 V 240 V 277 V 208 V 240 V 277 VAC Grid Connection Type Single phase / Split phaseRated AC Power (Pacr) 5000 W 6000 WMaximum AC Output Power (Pacmax) 5000 W 6000 WRated AC Grid Voltage (Vac,r) 208 V 240 V 277 V 208 V 240 V 277 VAC Voltage Range 183...228 V 211...264 V 244...304 V 183...228 V 211...264 V 244...304 VMaximum AC Output Current (Iac,max) 27.0 A 23.0 A 20.0 A 30.0 A 28.0 A 24.0 ARated Output Frequency (fr) 60 HzOutput Frequency Range (fmin...fmax) 59.3...60.5 HzNominal Power Factor (Cosphiac,r) > 0.995Total Current Harmonic Distortion < 2%AC Connection Type Screw terminal blockOutput Protection 208 V 240 V 277 V 208 V 240 V 277 VAnti-Islanding Protection According to UL 1741/IEE1547Maximum AC Overcurrent Protection 35.0 A 30.0 A 25.0 A 40.0 A 35.0 A 30.0 AOutput Overvoltage Protection - Varistor 2 (L1 - L2 / L1 - PE)Operating Performance 208 V 240 V 277 V 208 V 240 V 277 VMaximum Efficiency (ηmax) 97.1% 97.1%Weighted Efficiency (EURO/CEC) 96.0% 96.5% 96.5% 96.0% 96.5% 96.5%Feed In Power Threshold 20.0 WStand-by Consumption < 8.0 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+60°C (-13...+ 140°F) with derating above 50°C (122°F)Relative Humidity 0...100% condensingNoise Emission <50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65Cooling NaturalDimension (H x W x D) 1052mm x 325mm x222mmm / 41.4” x 12.8” x 8.7”Weight < 27.0 kg / 59.5 lbMounting System Wall bracketSafetyIsolation Level TransformerlessMarking cCSAusSafety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01Grid Standard IEEE 1547Available Products VariantsWith DC Switch PVI-5000-OUTD-US PVI-6000-OUTD-US

Page 52: Renewable Energy Solutios

52 AURORA TRIO

Page 53: Renewable Energy Solutios

TRIO

53AURORA TRIO

UNO

TRIO

Page 54: Renewable Energy Solutios

PVI-10.0-IPVI-12.0-I

GENERAL SPECIFICATIONSOUTDOOR MODELS

PVI-10.0-I-OUTD-400PVI-10.0-I-OUTD-US-208PVI-10.0-I-OUTD-US-480PVI-10.0-I-OUTD-CAN-600PVI-12.0-I-OUTD-400PVI-12.0-I-OUTD-US-480PVI-12.0-I-OUTD-CAN-600

54 AURORA TRIO

Europe and APAC Version

North America Versions

-S2 version

-S version

Page 55: Renewable Energy Solutios

Features

‘Electrolyte-free’ power converter to further increase the life expectancy and long term reliabilityTrue three-phase bridge topology for DC/AC output converterEach inverter is set on specific grid codes which can be selected in the fieldNight Wake up button to access energy harvesting data and error logDual input sections with independent MPP tracking, allows optimal energy harvesting from two sub-arrays oriented in diff erent directionsHigh speed and precise MPPT algorithm for real time power tracking and improved energy harvestingFlat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power rangeOutdoor enclosure for unrestricted use under any environmental conditionsIntegrated DC disconnect switch in compliance with international Standards (-S and -S2 version)RS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP

•••••

••••

Designed for commercial usage, this three-phase inverter is highly unique in its ability to control the performance of the PV panels, especially during periods of variable weather conditions. This device has two independent MPPTs and efficiency ratings of up to 97.3%.

The input voltage range makes the inverter suitable to installations with reduced string size. The HF isolation allows positive or negative ground configuration.

It is available with an optional fully-integrated DC and AC disconnect (-S2 version).The unit is free of electrolytic capacitors, leading to a longer product lifetime.

55AURORA TRIO

UNO

TRIO

Page 56: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

56 AURORA TRIO

PVI-10.0-I-OUTD PVI-12.0-I-OUTD

90

91

92

93

94

95

96

97

98

99

100

E�ci

ency

, %

% of Rated Output Power

220 Vdc

362 Vdc

416 Vdc

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

90

91

92

93

94

95

96

97

98

99

100

E�ci

ency

, %

% of Rated Output Power

250 Vdc

370 Vdc

416 Vdc

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

BLOCK DIAGRAM OF PVI-10.0-I AND PVI-12.0-I FOR NORTH AMERICA

IN1

+

-

MPPT 1(DC/DC)

IN2

+

-

MPPT 2(DC/DC)

BULK CAPSINVERTER(DC/AC)

LINEFILTER

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

GRID PARALLELRELAY

L1

L2

L3

N

PE

GROUNDFAULT

DETECTION

HFTRANSFORMER

HFTRANSFORMER

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1

IN2

+

-

+

-

IN2.1(+)

IN1.2(+)

IN2.1(-)

IN2.2(-)

STANDARD VERSION

IN1

IN2

+

-

+

-

-S VERSION

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

-S2 VERSION (5)

L1 L1, S

L2 L2, S

L3 L3, S

N N, S

PE

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN2.1(+)

IN2.2(+)

IN2.1(-)

IN2.2(-)

(1)

(1)

IN1

IN2

+

-

+

-

-S2 VERSION-NG

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1.3(+)

IN1.3(-)

(1)

(1)

(1) if -PG version switch and fuses are on negative polarity.

IN2.1(+)

IN2.2(+)

IN2.1(-)

IN2.2(-)

IN2.3(+)

IN2.3(-)

(1)

(1)

(5) for PVI-10.0-I-OUTD-208 Δ or connectionfor PVI-10.0-I-OUTD-480 Δconnection only

γ

Page 57: Renewable Energy Solutios

57AURORA TRIO

PARAMETER PVI-10.0-I-OUTD-400 PVI-12.0-I-OUTD-400

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 520 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...520 VRated DC Input Power (Pdcr) 10500 W 12300 WNumber of Independent MPPT (4) 2Maximum DC Input Power for each MPPT (PMPPTmax) 6800 WDC Input Voltage Range with Parallel Configuration of MPPT at Pacr 220...470 V 250...470 VDC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [470V≤VMPPT≤520V]

DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example

6800 W [285V≤VMPPT≤470V] the other channel: Pdcr-6800W

[155V≤VMPPT≤470V]

6800 W [275V≤VMPPT≤470V] the other channel: Pdcr-6800W

[220V≤VMPPT≤470V] Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 48.0 A / 24.0 A 50.0 A / 25.0 AMaximum Input Short Circuit Current for each MPPT 29.0 ANumber of DC Inputs Pairs for each MPPT 2DC Connection Type Tool Free PV Connector WM / MC4 Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control According to local standardDC Switch Rating for each MPPT (-S Version) 32 A / 600 VFuse Rating (-FS Version) Not applicableOutput SideAC Grid Connection Type Trifase (Δ/Y)Rated AC Power (Pacr) 10000 W 12000 WMaximum AC Output Power (Pacmax) 11000 W (3) 12500 WRated AC Grid Voltage (Vac,r) 400 VAC Voltage Range 320...480 V (1)

Maximum AC Output Current (Iac,max) 16.0 A 18.0 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (2)

Nominal Power Factor (Cosphiac,r) > 0.995 (adj. ± 0.9)Total Current Harmonic Distortion < 2%AC Connection Type Screw terminal blockOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 20.0 AOutput Overvoltage Protection - Varistor 3 plus gas arresterOperating PerformanceMaximum Efficiency (ηmax) 97.3%Weighted Efficiency (EURO/CEC) 97.0% / - Feed In Power Threshold 30 WStand-by Consumption < 8 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmental

Ambient Temperature Range -25...+60°C /-13...140°F with derating above 50°C/122°F

-25...+60°C /-13...140°F with derating above 45°C/113°F

Relative Humidity 0...100% condensingNoise Emission < 50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65Cooling NaturalDimension (H x W x D) 716mm x 645mm x 222mm / 28.2” x 25.4” x 8.7”Weight < 45.8 kg / 99.0 lbMounting System Wall bracketSafetyIsolation Level HF transformerMarking CESafety and EMC Standard EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-11, EN61000-3-12Grid Standard Enel Guideline, VDE 0126-1-1, G59/2, EN 50438, RD1663, AS 4777Available Products VariantsStandard PVI-10.0-I-OUTD-400 PVI-12.0-I-OUTD-400With DC Switch PVI-10.0-I-OUTD-S-400 PVI-12.0-I-OUTD-S-400

1. The AC voltage range may vary depending on specific country grid standard

2. The Frequency range may vary depending on specific country grid standard

3. Limited to 10000 W for Benelux

4. Independent MPPT just with negative ground

Page 58: Renewable Energy Solutios

58 AURORA TRIO

PARAMETER PVI-10.0-I-OUTD-US-208

PVI-10.0-I-OUTD-US-480

PVI-10.0-I-OUTD-CAN-600

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 520 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...520 VRated DC Input Power (Pdcr) 10500 WNumber of Independent MPPT (4) 2Maximum DC Input Power for each MPPT (PMPPTmax) 6800 WDC Input Voltage Range with Parallel Configuration of MPPT at Pacr 220...470 VDC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [470V≤VMPPT≤520V]

DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example

6800 W [285V≤VMPPT≤470V] the other channel: Pdcr-

6800W [155V≤VMPPT≤470V]

6800 W [285V≤VMPPT≤470V] the other channel: Pdcr-

6800W [220V≤VMPPT≤470V]

6800 W [285V≤VMPPT≤470V] the other channel: Pdcr-6800W

[155V≤VMPPT≤470V] Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 48.0 A / 24.0 AMaximum Input Short Circuit Current for each MPPT 29.0 ANumber of DC Inputs Pairs for each MPPT 2 (3 on -S2 Version) DC Connection Type Screw Terminal Block, 3 Knock-Outs: ¾” or 1” /w/ring red.)Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control GFDI (for use with either Positive or Negative Grounded Arrays)DC Switch Rating for each MPPT (-S Version) 32 A / 600 VFuse Rating (-FS Version) 12 A or 15 A / 600 V (1)

Output SideAC Grid Connection Type Trifase (Δ/Y)Rated AC Power (Pacr) 10000 WMaximum AC Output Power (Pacmax) 11000 WRated AC Grid Voltage (Vac,r) 208 V 480 V 600 VAC Voltage Range 183...228 V 422...528 V 528...660 VMaximum AC Output Current (Iac,max) 30.0 A 14.0 A 10.6 ARated Output Frequency (fr) 60 HzOutput Frequency Range (fmin...fmax) 59.3...60.5 HzNominal Power Factor (Cosphiac,r) > 0.995Total Current Harmonic Distortion < 2%AC Connection Type Screw Terminal Block, 3 Knock-Outs: ¾” Output ProtectionAnti-Islanding Protection According to UL 1741/IEE1547Maximum AC Overcurrent Protection 35.0 A 20.0 A 20.0 AOutput Overvoltage Protection - Varistor 3 plus gas arresterOperating PerformanceMaximum Efficiency (ηmax) 96.5% 97.3% 97.3%Weighted Efficiency (EURO/CEC) - / 96.0% - / 97.0% - / 97.0%Feed In Power Threshold 30 WStand-by Consumption < 8 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmental

Ambient Temperature Range -25...+60°C /-13...140°F with derating above 40°C/104°F

-25...+60°C /-13...140°F with derating above 50°C/122°F

-25...+60°C /-13...140°F with derating above 45°C/113°F

Relative Humidity 0...100% condensingNoise Emission < 50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating NEMA 4XCooling Natural

Dimension (H x W x D) 716mm x 645mm x 222mm / 28.2” x 25.4” x 8.7” 958mm x 645mm x 222mm / 37.7” x 25.4” x 8.7” (-S/-S2 version)

Weight < 45.8 kg / 99.0 lb

< 48.5 kg / 107 lb (-S Version) < 51.7 / 114 lb (-S2 Version)

Mounting System Wall bracketSafetyIsolation Level HF transformerMarking cCSAusSafety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01Grid Standard IEEE 1547Available Products VariantsStandard - Positive Ground PVI-10.0-I-OUTD-US-208-PG PVI-10.0-I-OUTD-US-480-PG PVI-10.0-I-OUTD-CAN-600-PGStandard - Negative Ground PVI-10.0-I-OUTD-US-208-NG PVI-10.0-I-OUTD-US-480-NG PVI-10.0-I-OUTD-CAN-600-NGWith DC Switch - Positive Ground PVI-10.0-I-OUTD-S-US-208-PG PVI-10.0-I-OUTD-S-US-480-PG PVI-10.0-I-OUTD-S-CAN-600-PGWith DC Switch - Negative Ground PVI-10.0-I-OUTD-S-US-208-NG PVI-10.0-I-OUTD-S-US-480-NG PVI-10.0-I-OUTD-S-CAN-600-NGWith AC and DC Switches - Positive Ground PVI-10.0-I-OUTD-S2-US-208-PG PVI-10.0-I-OUTD-S2-US-480-PG PVI-10.0-I-OUTD-S2-CAN-600-PGWith AC and DC Switches - Negative Ground PVI-10.0-I-OUTD-S2-US-208-NG PVI-10.0-I-OUTD-S2-US-480-NG PVI-10.0-I-OUTD-S2-CAN-600-NG

1. Order separately2. Just for -480 version, the inverter applies current limit derating below 220V down to 2A/1A at 90V

4. Independent MPPT just with negative ground

Page 59: Renewable Energy Solutios

59AURORA TRIO

PARAMETER PVI-12.0-I-OUTD-US-480 PVI-12.0-I-OUTD-CAN-600

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 520 VStart-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...520 VRated DC Input Power (Pdcr) 12300 WNumber of Independent MPPT (4) 2Maximum DC Input Power for each MPPT (PMPPTmax) 6800 WDC Input Voltage Range with Parallel Configuration of MPPT at Pacr 250...470 VDC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [470V≤VMPPT≤520V]

DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example

6800 W [275V≤VMPPT≤470V] the other channel: Pdcr-6800W [220V≤VMPPT≤470V]

Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 50.0 A / 25.0 A (2)

Maximum Input Short Circuit Current for each MPPT 29.0 ANumber of DC Inputs Pairs for each MPPT 2 (3 on -S2 Version) DC Connection Type Screw Terminal Block, 3 Knock-Outs: ¾” or 1” /w/ring red.)Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control GFDI (for use with either Positive or Negative Grounded Arrays)DC Switch Rating for each MPPT (-S Version) 32 A / 600 VFuse Rating (-FS Version) 12 A or 15 A / 600 V (1)

Output SideAC Grid Connection Type Trifase (Δ/Y)Rated AC Power (Pacr) 12000 WMaximum AC Output Power (Pacmax) 12500 WRated AC Grid Voltage (Vac,r) 480 V 600 VAC Voltage Range 422...528 V 528...660 VMaximum AC Output Current (Iac,max) 16.0 ARated Output Frequency (fr) 60 HzOutput Frequency Range (fmin...fmax) 59.3...60.5 HzNominal Power Factor (Cosphiac,r) > 0.995Total Current Harmonic Distortion < 2%AC Connection Type Screw Terminal Block, 3 Knock-Outs: ¾” Output ProtectionAnti-Islanding Protection According to UL 1741/IEE1547Maximum AC Overcurrent Protection 20.0 AOutput Overvoltage Protection - Varistor 3 plus gas arresterOperating PerformanceMaximum Efficiency (ηmax) 97.3%Weighted Efficiency (EURO/CEC) - / 97.0%Feed In Power Threshold 30 WStand-by Consumption < 8 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+60°C /-13...140°F with derating above 45°C/113°FRelative Humidity 0...100% condensingNoise Emission < 50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating NEMA 4XCooling Natural

Dimension (H x W x D) 716mm x 645mm x 222mm / 28.2” x 25.4” x 8.7” 958mm x 645mm x 222mm / 37.7” x 25.4” x 8.7” (-S/-S2 version)

Weight < 45.8 kg / 99.0 lb

< 48.5 kg / 107 lb (-S Version) < 51.7 / 114 lb (-S2 Version)

Mounting System Wall bracketSafetyIsolation Level HF transformerMarking cCSAusSafety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01Grid Standard IEEE 1547Available Products VariantsStandard - Positive Ground PVI-12.0-I-OUTD-US-480-PG PVI-12.0-I-OUTD-CAN-600-PGStandard - Negative Ground PVI-12.0-I-OUTD-US-480-NG PVI-12.0-I-OUTD-CAN-600-NGWith AC and DC Switches - Positive Ground PVI-12.0-I-OUTD-S2-US-480-PG PVI-12.0-I-OUTD-S2-CAN-600-PGWith AC and DC Switches - Negative Ground PVI-12.0-I-OUTD-S2-US-480-NG PVI-12.0-I-OUTD-S2-CAN-600-NG

1. Order separately2. Just for -480 version, the inverter applies current limit derating below 220V down to 2A/1A at 90V4. Independent MPPT just with negative ground

Page 60: Renewable Energy Solutios

PVI-10.0-TLPVI-12.5-TL

GENERAL SPECIFICATIONSOUTDOOR MODELS

PVI-10.0-TL-OUTDPVI-10.0-TL-OUTD-SPVI-10.0-TL-OUTD-FS

PVI-12.5-TL-OUTDPVI-12.5-TL-OUTD-SPVI-12.5-TL-OUTD-FS

60 AURORA TRIO

Page 61: Renewable Energy Solutios

Features

61AURORA TRIO

‘Electrolyte-free’ power converter to further increase the life expectancy and long term reliabilityTrue three-phase bridge topology for DC/AC output converterEach inverter is set on specific grid codes which can be selected in the fieldDual input sections with independent MPP tracking, allows optimal energy harvesting from two sub-arrays oriented in diff erent directionsWide input rangeHigh speed and precise MPPT algorithm for real time power tracking and improved energyharvestingFlat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power rangeOutdoor enclosure for unrestricted use under any environmental conditionsIntegrated DC disconnect switch in compliance with international Standards (-S Version)RS-485 communication interface (for connection to laptop or datalogger)Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP

••••

••

••••

The three-phase 10.0 and 12.5 kW non-isolated inverter is an industry leader.

Designed for commercial usage, this three-phase inverter is highly unique in its ability to control the performance of the PV panels, especially during periods of variable weather conditions. This transformerless device has two independent MPPTs and efficiency ratings of up to 97.7%.

The wide input voltage range makes the inverter suitable to low power installations with reduced string size. It is available with an optional fully-integrated DC switch, fuse and remote controlled DC disconnect function. The unit is free of electrolytic capacitors, leading to a longer product lifetime.

UNO

TRIO

Page 62: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

62 AURORA TRIO

PVI-10.0-TL-OUTD PVI-12.5-TL-OUTD

5,00%

10,00%

15,00%

20,00%

25,00%

30,00%

35,00%

40,00%

45,00%

50,00%

55,00%

60,00%

65,00%

70,00%

75,00%

80,00%

85,00%

90,00%

95,00%

100,00%

300 330 360 390 420 450 480 510 540 570 600 630 660 690 720 750

% P

out n

om

Vin [Vdc]

97,50-98,00

97,00-97,50

96,50-97,00

96,00-96,50

95,50-96,00

95,00-95,50

94,50-95,00

94,00-94,50

93,50-94,00

93,00-93,50

92,50-93,00

97.8 97.5

97.0

96.5

96.0

93.0

95.0

90%

91%

92%

93%

94%

95%

96%

97%

98%

99%

0% 6% 13% 19% 25% 31% 38% 44% 50% 56% 63% 69% 75% 81% 88% 94% 100%

E�ci

ency

[%]

% of rated Output Power

300 Vdc

570 Vdc

750 Vdc

BLOCK DIAGRAM OF PVI-10.0-TL-OUTD AND PVI-12.5-TL-OUTD

IN1

+

-

MPPT 1(DC/DC)

IN2

+

-

MPPT 2(DC/DC)

BULK CAPSINVERTER(DC/AC)

LINEFILTER

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

GRID PARALLELRELAY

L1

L2

L3

N

PE

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1

IN2

+

-

+

-

IN2.1(+)

IN2.2(+)

IN2.1(-)

IN2.2(-)

STANDARD VERSION

IN1

IN2

+

-

+

-

-S VERSION

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN2.1(+)

IN2.2(+)

IN2.1(-)

IN2.2(-)

IN1

IN2

+

-

+

-

-FS VERSION

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1.3(+)

IN1.3(-)

IN2.1(+)

IN2.2(+)

IN2.1(-)

IN2.2(-)

IN2.3(+)

IN2.3(-)

IN1.3(+)

IN1.3(-)

IN2.3(+)

IN2.3(-)

Page 63: Renewable Energy Solutios

63AURORA TRIO

PARAMETER PVI-10.0-TL-OUTD PVI-12.5-TL-OUTD

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 900 VStart-up DC Input Voltage (Vstart) 360 V (adj. 250...500 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...850 VRated DC Input Power (Pdcr) 10300 W 12800 WNumber of Independent MPPT 2Maximum DC Input Power for each MPPT (PMPPTmax) 6800 W 8000 WDC Input Voltage Range with Parallel Configuration of MPPT at Pacr 300...750 V 360...750 WDC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [750V≤VMPPT≤850V]

DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example

6800 W [380V≤VMPPT≤750V] the other channel: Pdcr-6800W

[195V≤VMPPT≤750V]

8000 W [445V≤VMPPT≤750V] the other channel: Pdcr-8000W

[270V≤VMPPT≤750V] Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 36.0 A / 18.0 AMaximum Input Short Circuit Current for each MPPT 22.0 ANumber of DC Inputs Pairs for each MPPT 2 (-S Version) 3 (Standard or –FS Version)DC Connection Type Tool Free PV Connector WM / MC4 Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Photovoltaic Array Isolation Control According to local standardDC Switch Rating for each MPPT (-S Version) 25 A / 1000 V Fuse Rating (-FS Version) 10 A / 1000 VOutput SideAC Grid Connection Type Three phase (Δ/Y)Rated AC Power (Pacr) 10000 W 12500 WMaximum AC Output Power (Pacmax) 11000 W (3) 13800 WRated AC Grid Voltage (Vac,r) 400 VAC Voltage Range 320...480 VMaximum AC Output Current (Iac,max) 16.6 A 20.0 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (2)

Nominal Power Factor (Cosphiac,r) > 0.995 (adj. ± 0.9)Total Current Harmonic Distortion < 2%AC Connection Type Screw terminal blockOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 19.0 A 22.0 AOutput Overvoltage Protection - Varistor 3 plus gas arresterOperating PerformanceMaximum Efficiency (ηmax) 97.8%Weighted Efficiency (EURO/CEC) 97.1% / - 97.2% / -Feed In Power Threshold 30.0 WStand-by Consumption < 10.0 WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmental

Ambient Temperature Range -25...+60°C (-13...+140°F) with derating above 55°C (131°F)

-25...+60°C /-13...140°F with derating above 50°C/122°F

Relative Humidity 0...100% condensingNoise Emission < 50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65Cooling NaturalDimension (H x W x D) 716mm x 645mm x 222mm / 28.2” x 25.4” x 8.7”Weight < 41.0 kg / 90.4 lbMounting System Wall bracketSafetyIsolation Level TransformerlessMarking CESafety and EMC Standard EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12Grid Standard DK 5940, VDE 0126-1-1, G59, EN 50438, RD1663, AS 4777, BDEWAvailable Products VariantsStandard PVI-10.0-TL-OUTD PVI-12.5-TL-OUTDWith DC Switch PVI-10.0-TL-OUTD-S PVI-12.5-TL-OUTD-SWith DC Switch and Fuse PVI-10.0-TL-OUTD-FS PVI-12.5-TL-OUTD-FS

1. The AC voltage range may vary depending on specific country grid standard2. The Frequency range may vary depending on specific country grid standard3. Limited to 10000 W for Benelux

Page 64: Renewable Energy Solutios

TRIO-27.6-TLTRIO-20.0-TL

GENERAL SPECIFICATIONSOUTDOOR MODELS

TRIO-27.6-TL-OUTDTRIO-20.0-TL-OUTD

64 AURORA TRIO

NEW

Page 65: Renewable Energy Solutios

65AURORA TRIO

Features

‘Electrolyte-free’ power converter to further increase the life expectancy and long term reliabilityQuiet RailTrue three-phase bridge topology for DC/AC output converterEach inverter is set on specific grid codes which can be selected in the fieldDual input sections with independent MPP tracking, allows optimal energy harvesting from two sub-arrays oriented in diff erent directionsWide input rangeDetachable wiring box to allow an easy installationIntegrated string combiner with diff erent options of configuration which include DC and ACdisconnect switch in compliance with international Standards (-S2 and -S2X version)High speed and precise MPPT algorithm for real time power tracking and improved energy harvestingFlat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power rangeOutdoor enclosure for unrestricted use under any environmental conditions

•••••••••••

The latest in Power-One’s Aurora Trio range, this new-look three-phase inverter fills a specific niche in the commercial solar market. This new three-phase inverter benefits from the three-phase inverter technology perfected in the PVI-10.0 and 12.5, probably the world’s most commonly used three-phase inverter which has led the way in best-in-class efficiency.

Controlling more PV panels than its smaller predecessor, the Trio-27.6 and Trio-20.0 willoff er more fl exibility and control to installers who have large installations with varying aspects or orientations. This device has two independent MPPTs and efficiency ratings of up to 98.2%. The very wide input voltage range makes the inverter suitable to installations with reduced string size.

The new look inverter has new features including a special built-in heat sink compartment and front panel display system. The unit is free of electrolytic capacitors, leading to a longer product lifetime.

UNO

TRIO

Page 66: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

66 AURORA TRIO

TRIO-20.0-TL-OUTD TRIO-27.6-TL-OUTD

BLOCK DIAGRAM OF TRIO-27.6-TL- OUTD

-S2X VERSION

IN1

IN1A(+)

IN1C(+)

IN1D(+)

*IN1E(+)

IN1B(+)

IN1A(-)

IN1C(-)

IN1D(-)

*IN1E(-)

IN1B(-)

IN2

IN2A(+)

IN2C(+)

IN2D(+)

*IN2E(+)

IN2B(+)

IN2A(-)

IN2C(-)

IN2D(-)

*IN2E(-)

IN2B(-)

CURRENTREADING

CURRENTREADING

OVPMONITORING

OVPMONITORING

IN1

+

-

MPPT 1(DC/DC)

IN2

+

-

MPPT 2(DC/DC)

BULK CAPSINVERTER(DC/AC)

LINEFILTER

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

µP

CONTROL CIRCUIT

GRID PARALLELRELAY

L1

L2

L3

N

PE

-S2 VERSION

L1 L1, S

L2 L2, S

L3 L3, S

N N, S

PE

PC_RS485

+ T/R

- T/R

GND

REMOTE CONTROL

+ R

GND

ALARM

N.C

N.O

C

PVI-RADIOMODULE

(OPT)

PT 100

PT 1000

4...20mA / 0...10V adj

4...20mA / 0...10V adj

ON/OFF EXT

WIRING BOX CIRCUIT

-S2X VERSION

L1 L1, S

L2 L2, S

L3 L3, S

N N, S

PE

PMU_RS485

+ T/R

- T/R

GND

SDCARD

IN1(+)

IN1(-)

IN1

IN2

+

-

+

-

IN2(+)

IN2(-)

STANDARD VERSION

IN1(+)

IN1(-)

IN1

IN2

+

-

+

-

IN2(+)

IN2(-)

-S2 VERSION

CURRENT READING

OVP MONITORING

GRID STANDARD SETTING

SERVICE OR NORMAL

PC

PMU

AN 1

AN 2

IN MODE

1

2

* not present on TRIO-20.0-TL

1 INVERTER2 WIRING BOX

* an expansion slot for future implementation of new communication systems is available

*

90

91

92

93

94

95

96

97

98

99

100

E�ci

ency

, %

% of Rated Output Power

500 Vdc

620 Vdc

800 Vdc

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

90

91

92

93

94

95

96

97

98

99

100

E�ci

ency

, %

% of Rated Output Power

500 Vdc

620 Vdc

800 Vdc

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

Page 67: Renewable Energy Solutios

67AURORA TRIO

PARAMETER TRIO-20.0-TL-OUTD TRIO-27.6-TL-OUTD

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 1000 VStart-up DC Input Voltage (Vstart) 360 V (adj. 250...500 V)Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...970 VRated DC Input Power (Pdcr) 20750 W 28600 WNumber of Independent MPPT 2Maximum DC Input Power for each MPPT (PMPPTmax) 12000 W 16000 WDC Input Voltage Range with Parallel Configuration of MPPT at Pacr 440...800 V 500...800 V

DC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [800V≤VMPPT≤950V]

Linear Derating From MAX to Null [800V≤VMPPT≤950V]

DC Power Limitation for each MPPT with Independent Configuration of MPPT at Pacr , max unbalance example

12000 W [480V≤VMPPT≤800V] the other channel: Pdcr-12000W

[350V≤VMPPT≤800V]

16000 W [500V≤VMPPT≤800V] the other channel: Pdcr-16000W

[400V≤VMPPT≤800V]Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 50.0 A / 25.0 A 64.0 A / 32.0 AMaximum Input Short Circuit Current for each MPPT 30.0 A 40.0 ANumber of DC Inputs Pairs for each MPPT 1 (4 on -S2X version) 1 (5 on -S2X version)DC Connection Type Tool Free PV Connector WM / MC4Input ProtectionReverse Polarity protection Yes, from limited current sourceInput Over Voltage Protection for each MPPT - Varistor 2Input Over Voltage Protection for each MPPTPlug In Modular Surge Arrester (-S2X Version) 3 (Classe II)

Photovoltaic Array Isolation Control According to local standardDC Switch Rating for each MPPT (-S Version) 40 A / 1000 VFuse Rating (-FS Version) 10 A / 1000 VOutput SideAC Grid Connection Type Three phase (Δ/Y)Rated AC Power (Pacr) 20000 W 27600 WMaximum AC Output Power (Pacmax) 22000 W 30000 WRated AC Grid Voltage (Vac,r) 400 VAC Voltage Range 320...480 V (1)

Maximum AC Output Current (Iac,max) 33.0 A 45.0 ARated Output Frequency (fr) 50 HzOutput Frequency Range (fmin...fmax) 47...53 Hz (2)

Nominal Power Factor (Cosphiac,r) > 0.995 (adj. ± 0.9)Total Current Harmonic Distortion < 3%AC Connection Type Cage clampOutput ProtectionAnti-Islanding Protection According to local standardMaximum AC Overcurrent Protection 34.0 A 46.0 AOutput Overvoltage Protection - Varistor 4Output Over Voltage Protection Plug In Modular Surge Arrester (-S2X Version) 4 (Class II)

Operating PerformanceMaximum Efficiency (ηmax) 98.2%Weighted Efficiency (EURO/CEC) 98.0% / 98.0%Feed In Power Threshold 40 WStand-by Consumption < 8WCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface Graphic displayEnvironmentalAmbient Temperature Range -25...+60°C /-13...140°F with derating above 45°C/113°FRelative Humidity 0...100% condensingNoise Emission < 50 db(A) @ 1 mMaximum Operating Altitude without Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65Cooling NaturalDimension (H x W x D) 1060mm x 751mm x 291mm / 41.7” x 29.6” x 11.4”Weight < 70.0 kg / 154.3 lb < 75.0 kg / 165.4 lbMounting System Wall bracketSafetyIsolation Level TransformerlessMarking CESafety and EMC Standard EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-1, EN61000-6-3, EN61000-3-11, EN61000-3-12Grid Standard Enel Guideline, VDE 0126-1-1, G59/2, EN 50438, RD1663, AS 4777Available Products VariantsStandard TRIO-20.0-TL-OUTD-400 TRIO-27.6-TL-OUTD-400With DC Switch TRIO-20.0-TL-OUTD-S2-400 TRIO-27.6-TL-OUTD-S2-400With DC Switch and Fuse TRIO-20.0-TL-OUTD-S2X-400 TRIO-27.6-TL-OUTDS2X-400

1. The AC voltage range may vary depending on specific country grid standard2. The Frequency range may vary depending on specific country grid standard

Page 68: Renewable Energy Solutios

68 AURORA LITE

Page 69: Renewable Energy Solutios

LITELI

TEPL

USUL

TRA

69AURORA LITE

Page 70: Renewable Energy Solutios

PVI-250PVI-500

GENERAL SPECIFICATIONSCENTRALIZED MODELS

PVI-250.0-TL-CNPVI-500.0-TL-CN

70 AURORA LITE

NEW

PVI-250-TL-CN

Page 71: Renewable Energy Solutios

71AURORA LITE

Features

Reverse-polarity protection minimizes potential damage caused by array mis-wiringMaximum input voltage up to 1000 Vdc, high design fl exibility and reduced DC distribution losses for large scale PV plantsTransformer-less inverter for direct connection to MV transformerIntegrated DC and AC distribution and protection. Fully equipped for connection, additionalaccessories not requiredHigh efficiencies deliver more energyTwo independent RS-485 communication interfaces for inverter and intelligent stringcombiner monitoring

••

••

••

This product off ers high performance with aff ordable capital expenditure and has been specifically designed for the fast growing Asian market.

Power-One’s new 250kW and 500kW utility grade central inverters have a number of key features, including a very high efficiency of 98.5%, electrolytic capacitor-free leading to longer MTBF (mean time between failures), compact size and weight; touch screen display, and 1000 Voc (open circuit voltage) rating.

This product design is the result of the experience we have acquired with more than 50MW of installation in the challenging Asian market.

LITE

PLUS

ULTR

A

Page 72: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

72 AURORA LITE

PVI-250.0-TL-CN

BLOCK DIAGRAM OF PVI-500.0-TL

PV ARRAY 1(+)

PV ARRAY 3(+)

PV ARRAY 4(+)

PV ARRAY 5(+)

PV ARRAY 2(+)

INVERTER 1

GRID CONTROL

ACFILTER

EMIFILTER

A

GROUND FAULTDETECTION

/REVERSE POLARITY

DETECTION

PVISTRINGCOMB

PVIDISPLAY

PVIAEC-EVO

L1

L2

L3

INVERTER 1

GRID CONTROL

ACFILTER

EMIFILTER

A

GROUND FAULTDETECTION

/REVERSE POLARITY

DETECTION

P

OVR

OVR

24 VDC

LS3 NLS2LS1

208 VACCONTROL CIRCUIT

AC BREAKER

RSTN

PE

AUX POWERCONNECTION

TO EACH 250kW BLOCK

PV ARRAY 1(-)

PV ARRAY 3(-)

PV ARRAY 4(-)

PV ARRAY 5(-)

PV ARRAY 2(-)

PV ARRAY 6(+)

PV ARRAY 8(+)

PV ARRAY 9(+)

PV ARRAY 10(+)

PV ARRAY 7(+)

PV ARRAY 6(-)

PV ARRAY 8(-)

PV ARRAY 9(-)

PV ARRAY 10(-)

PV ARRAY 7(-)

E�ci

ency

, %

% of Rated Output Power

91,0

92,0

93,0

94,0

95,0

96,0

97,0

98,0

99,0

0,0% 10,0% 20,0% 30,0% 40,0% 50,0% 60,0% 70,0% 80,0% 90,0% 100,0% 110,0%

480 Vdc

600 Vdc

810 Vdc

Page 73: Renewable Energy Solutios

73AURORA LITE

PARAMETER PVI-250.0-TL-CN PVI-500.0-TL-CN

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 1000 V 1000 VMPPT Input DC Voltage Range (VMPPTmin,r ... VMPPTmax,r) 475....900 V 475....900 VMPPT Input DC Range (VMPPTmin,f ... VMPPTmax,f) at Full Power 475....900 V 475....900 VNumber of Independent MPPT Multi-Master 1 2Number of Independent MPPT Master/Slave Not applicable 1Maximum Combined DC Input Current (Idcmaxc) 550 A 1100 AMaximum DC Input Current for Each Module (Idcmax,m) 550 A 550 ANumber of DC Inputs Pairs 5 10DC Connection Type 10 x 70 mm2 (M10) 20 x 70 mm2 (M10)Input ProtectionReverse Polarity Protection Yes, from limited current source Yes, from limited current sourceInput Over Voltage Protection - Varistor 2 for each input, Class II 2 for each input, Class IIPhotovoltaic Array Isolation Control According to local standard According to local standardFuse Size for Each Input Pair 125 A / 1100 V 125 A / 1100 V Output SideAC Grid Connection Type Three phases (Δ / Υ) Three phases (Δ)Rated AC Power (Pac,r) 250 kW 500 kWRated Grid Voltage (Vac,r) 320 V 320 VAC Voltage Range (Vacmin...Vacmax) 272...368 V (1) 272...368 V (1)

Maximum Output Current (Iac,max) 450 A 900 ARated Frequency (fr) 50/60 Hz 50/60 HzFrequency Range (fmin...fmax) 47...53 / 57...63 Hz (2) 47...53 / 57...63 Hz (2)

Power Factor (Cosphiac,r) > 0.995 (adj. ± 0.90) (3) > 0.995 (adj. ± 0.90) (3)

Total Harmonic Distortion < 3% (@ Pac,r) < 3% (@ Pac,r)AC Connection Type 3 x 240 mm2 (M10) 3 x 240 mm2 (M10)Output ProtectionAnti-Islanding Protection According to local standard According to local standardOutput Overvoltage Protection (Varistor) 3, star connected, Class II 3, star connected, Class IINight Time Disconnect Yes YesAC Circuit Breaker 690 V / 630 A (T5) 690 V / 1kA (T6)Operating PerformanceMaximum Efficiency (ηmax) 98.5% 98.5%Weithted Efficiency (ηEURO / ηCEC) 98.2% / - 98.2% / -Stand-by Consumption/Night-time power loss < 33 W < 66 WAC Auxiliary Supply 3 x 400 Vac +N, 50/60 Hz 3 x 400 Vac +N, 50/60 HzAuxiliary Supply Consumption < 405 W < 810 WAuxiliary Supply Consumption without Cooling < 100 W < 220 WInverter Switching Frequency 9 kHz 9 kHzCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.) PVI-USB-RS485_232 (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)AURORA String Combiner PVI-STRINGCOMB (opt.) PVI-STRINGCOMB (opt.)User Interface TFT LCD 5.7” TFT LCD 5.7”Environmental

Ambient Temperature Range -20...+ 50°C/-4...122°Fwith derating above 45°C/113°F

-20...+ 50°C/-4...122°Fwith derating above 45°C/113°F

Relative Humidity 0...95% non condensing 0...95% non condensingNoise Emission <62 dB(A) @ 1 m <62 dB(A) @ 1 m Maximum Operating Altitude without Derating 1000 m / 3280 ft 1000 m / 3280 ftPhysical Environmental Protection Rating IP 20 IP 20Cooling Air Forced Air ForcedRequired Air Cooling Flow 4000 m3/h - 2360 CFM 8000 m3/h - 4720 CFMDimension (H x W x D) 2280mm x 1200mm x 800mm / 89.8” x 47.2” x31.5” 2280mm x 2000mm x 800mm / 89.8” x 78.7” x 31.5”Weight < 800 kg / 1765 lb < 1200 kg / 2645 lbSafetyTransformer No NoMarking CE, CQC CE, CQC

Safety and EMC Standard EN 50178, EN 61000-3-12, EN61000-6-2, EN61000-6-4, IEC 62109-1

EN 50178, EN 61000-3-12, EN61000-6-2, EN61000-6-4, IEC 62109-1

Grid Standard CNCA/CTS0004, GB/T 19939, IEC 62116 CNCA/CTS0004, GB/T 19939, IEC 62116

1. The AC voltage range may vary depending on specific country grid standard

2. The Frequency range may vary depending on specific country grid standard

3. Power factor variations beyond ±0.9 imply a reduction of the active power

Page 74: Renewable Energy Solutios

74 AURORA PLUS

Page 75: Renewable Energy Solutios

PLUS

75AURORA PLUS

LITE

PLUS

ULTR

A

Page 76: Renewable Energy Solutios

76 AURORA PLUS

PVI-55.0PVI-110.0PVI-165.0/220.0PVI-275.0/330.0

FeaturesReduced susceptibility to a single fault. In case of a component failure, a maximum of 55kW will be lostReduced acoustic noise due to the high switching frequencyReverse-polarity protection minimizes potential damage caused by array mis-wiringMaximum input voltage up to 1000Vdc, high design fl exibility and reduced DC distribution losses for large scale PV plantsIntegrated DC and AC distribution and protection. Fully equipped for connection, additional accessories not requiredEasy installation and maintenance procedure. Front extractible DC/AC converters and accessibility to all critical partsHigh efficiencies deliver more energyTwo independent RS-485 communication interfaces for inverter and intelligent string combiner monitoringIntegrated DC disconnect switch for each 55 kW module AC and DC side integrated protection (fuses and OVR) easily replaceableCompliant to BDEW

••••••••••

These extremely scalable modular inverter systems, based on 55kW modular blocks, increase usable power and improve availability. The reduction of performance in any individual module will not impact the energy-harvesting capabilities of other modules.

The product is available with and without transformer. Industry-leading power conversion efficiencies of up to 98% (-TL), combined with high-speed Maximum Power Point Tracking (MPPT) channels, optimize energy harvesting across a wide array of operating conditions.

Inverter systems are delivered pre-configured and pre-tested, significantly reducing on-site wiring and testing. In case of ungrounded application the unit can be configured as single or multiple MPPT (with exception of PVI-55.0/-TL).

Page 77: Renewable Energy Solutios

PVI-55.0/330.0-TL

90,00

91,00

92,00

93,00

94,00

95,00

96,00

97,00

98,00

99,00

100,00

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

[%

]

Pac / Pnom [%]

485Vdc

500Vdc

550Vdc

Block Diagram and Efficiency Curves

77AURORA PLUS

BLOCK DIAGRAM OF PVI-330.0 WITH TRANSFORMER (MULTI MASTER)

300kVATRANSFORMER

RST

MAIN AC POWERCONNECTION

PE

AC BREAKER

∆ /

Y

24 VDC

LS3 NLS2LS1

208 VACCONTROL CIRCUIT

AC BREAKER

RSTN

PE

AUX POWERCONNECTION

TO EACH 55.0 Kw MODULE

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

INVERTER MODULE 55.0kW

PV ARRAY 1 (+)

PV ARRAY 1 (-)

PV ARRAY 2 (+)

PV ARRAY 2 (-)

PV ARRAY 1 (+)

PV ARRAY 1 (-)

PV ARRAY 2 (+)

PV ARRAY 2 (-)

PV ARRAY 1 (+)

PV ARRAY 1 (-)

PV ARRAY 2 (+)

PV ARRAY 2 (-)

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

INVERTER MODULE 55.0kW

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

INVERTER MODULE 55.0kW

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

INVERTER MODULE 55.0kW

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

INVERTER MODULE 55.0kW

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

INVERTER MODULE 55.0kW

Page 78: Renewable Energy Solutios

PVI-55.0

78 AURORA PLUS

PVI-55.0PVI-55.0-TLPVI-110.0PVI-110.0-TL

GENERAL SPECIFICATIONSCENTRALIZED MODELS

PVI-55.0PVI-55.0-TLPVI-110.0PVI-110.0-TL

PVI-110.0

90,00

91,00

92,00

93,00

94,00

95,00

96,00

97,00

98,00

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

[%

]

Pac / Pnom [%]

485Vdc

500Vdc

550Vdc

90,00

91,00

92,00

93,00

94,00

95,00

96,00

97,00

98,00

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

[%

]

Pac / Pnom [%]

485Vdc

500Vdc

550Vdc

Effi ciency Curves

Page 79: Renewable Energy Solutios

79AURORA PLUS

PARAMETER PVI-55.0 PVI-55.0-TL PVI-110.0 PVI-110.0-TL

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 1000 V 1000 VMPPT Input DC Voltage Range (VMPPTmin,r ... VMPPTmax,r) 485...950 V 485...950 VMPPT Input DC Range (VMPPTmin,f ... VMPPTmax,f) at Full Power 485...850 V 485...850 VNumber of Independent MPPT Multi-Master 1 2Number of Independent MPPT Multi - Master/Slave Not applicable Not applicableNumber of Independent MPPT Master/Slave 1 1Maximum Combined DC Input Current (Idcmaxc) 124 A 248 AMaximum DC Input Current for Each Module (Idcmax,m) 124 A 124 ANumber of DC Inputs Pairs 1 2DC Connection Type 1x185mm2 (M10) 1x185mm2 (M10) + 1x300mm2 (M12)Input ProtectionReverse Polarity Protection YES, with series diode YES, with series diodeInput Over Voltage Protection - Varistor 2 for each input pair, Class II 2 for each input pair, Class IIPhotovoltaic Array Isolation Control According to local standard According to local standardFuse Size for Each Input Pair 125 A / 1000 V 125 A / 1000 VOutput SideAC Grid Connection Type Three phases (Δ / Υ) Three phases (Δ) Three phases (Δ / Υ) Three phases (Δ)Rated AC Power (Pac,r) 55 kW 110 kWRated Grid Voltage (Vac,r) 400 V 320 V 400V 320 VAC Voltage Range (Vacmin...Vacmax) 320...480 V (1) 256...368 V (1) 320...480 V (1) 256...368 V (1)

Maximum Output Current (Iac,max) 81 A 100 A 160 A 200 ARated Frequency (fr) 50/60 Hz 50/60 HzFrequency Range (fmin...fmax) 47...53 / 57...63 Hz (2) 47...53 / 57...63 Hz (2)

Power Factor (Cosphiac,r) > 0.995 (adj. ± 0.90) (3) > 0.995 (adj. ± 0.90) (3)

Total Harmonic Distortion < 3% (@ Pac,r) < 3% (@ Pac,r)AC Connection Type 1 x 95 mm2 (M8) 1 x 300 mm2 (M12) 1 x 95 mm2 (M8) 1 x 300 mm2 (M12)Output ProtectionAnti-Islanding Protection According to local standard According to local standardOutput Overvoltage Protection (Varistor) Yes, Class II Yes, Class IINight Time Disconnect Yes YesAC Circuit Breaker 50 kA 50 kAOperating PerformanceMaximum Efficiency (ηmax) 96.30% 98.00% 96.40% 98.00%Weithted Efficiency (ηEURO / ηCEC) 95.1% / 96.0% 97.7% / 98.0% 95.2% / 96.0% 97.7% / 98.0%Stand-by Consumption/Night-time power loss < 17 W < 23 W < 24 W < 19 WAC Auxiliary Supply 3x400 Vac +N, 50/60 Hz 3 x 400 Vac +N, 50/60 HzAuxiliary Supply Consumption < 0.36% of Pac,r < 0.24% of Pac,r < 0.31% of Pac,r < 0.24% of Pac,r

Auxiliary Supply Consumption without Cooling < 0.25% of Pac,r < 0.22% of Pac,r < 0.23% of Pac,r < 0.22% of Pac,r

Inverter Switching Frequency 18 kHz 18 kHzCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.) PVI-USB-RS485_232 (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)AURORA String Combiner PVI-STRINGCOMB (opt.) PVI-STRINGCOMB (opt.)User Interface 16 characters x 2 line LCD display for each module 16 characters x 2 line LCD display for each moduleEnvironmental

Ambient Temperature Range -10...+ 60°C/+14...140°F with derating above 50°C/122°F

-10...+ 60°C/+14...140°F with derating above 50°C/122°F

Relative Humidity 0...95% non condensing 0...95% non condensingNoise Emission <62 dB(A) @ 1 m < 63 db (A) @ 1 mMaximum Operating Altitude without Derating 1000 m / 3280 ft 1000 m / 3280 ftPhysical Environmental Protection Rating IP 20 IP 20Cooling Air Forced Air ForcedRequired Air Cooling Flow 1600 m3/h - 944 CFM 2800 m3/h - 1652 CFM 2400 m3/h - 1416 CFM

Dimension (H x W x D) 1675mm x 1250mm x 850mm / 69.5” x 49,2” x 33.5”

1077mm x 1250mm x 850mm / 42.4” x 49.2” x 33.5”

1675mm x 1250mm x 850mm / 65.9” x 49.2” x 33.5”

1077mm x 1250mm x 850mm / 42,4” x 49.2” x 33.5”

Weight < 700 kg / 1543 lb < 350 kg / 771 lb < 800 kg / 1765 lb < 480 kg / 1058 lbWeight of the module < 60 kg / 132 lb < 60 kg / 132 lbSafetyTransformer Yes No Yes NoMarking CE CE

Safety and EMC Standard EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12

EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12

Grid Standard Enel Guideline, BDEW, RD 1663 Enel Guideline, BDEW, RD 1663

1. The AC voltage range may vary depending on specific country grid standard

2. The Frequency range may vary depending on specific country grid standard

3. Power factor variations beyond ±0.9 imply a reduction of the active power

Page 80: Renewable Energy Solutios

PVI-165.0 / PVI-165.0-TLPVI-220.0 / PVI-220.0-TL

GENERAL SPECIFICATIONSCENTRALIZED MODELS

PVI-165.0PVI-165.0-TLPVI-220.0PVI-220.0-TL

80 AURORA PLUS

PVI-165.0 / PVI-165.0-TLPVI-220.0 / PVI-220.0-TL

PVI-55.0/330.0-TL PVI-165.0/220.0

90,00

91,00

92,00

93,00

94,00

95,00

96,00

97,00

98,00

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

Effi

cien

cy [

%]

Pac / Pnom [%]

485Vdc

500Vdc

550Vdc

90,00

91,00

92,00

93,00

94,00

95,00

96,00

97,00

98,00

99,00

100,00

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

[%

]

Pac / Pnom [%]

485Vdc

500Vdc

550Vdc

Effi ciency Curves

Page 81: Renewable Energy Solutios

81AURORA PLUS

PARAMETER PVI-165.0 PVI-165.0-TL PVI-220.0 PVI-220.0-TL

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 1000 V 1000 VMPPT Input DC Voltage Range (VMPPTmin,r ... VMPPTmax,r) 485...950 V 485...950 VMPPT Input DC Range (VMPPTmin,f ... VMPPTmax,f) at Full Power 485...850 V 485...850 VNumber of Independent MPPT Multi-Master 3 4Number of Independent MPPT Multi - Master/Slave 2 2Number of Independent MPPT Master/Slave 1 1Maximum Combined DC Input Current (Idcmaxc) 372 A 496 AMaximum DC Input Current for Each Module (Idcmax,m) 124 A 124 ANumber of DC Inputs Pairs 3 4DC Connection Type 2x185mm2 (M10) + 1x300mm2 (M12) 2x185mm2 (M10)+ 2x300mm2 (M12)Input ProtectionReverse Polarity Protection YES, with series diode YES, with series diodeInput Over Voltage Protection - Varistor 2 for each input pair, Class II 2 for each input pair, Class IIPhotovoltaic Array Isolation Control According to local standard According to local standardFuse Size for Each Input Pair 125 A / 1000 V 125 A / 1000 VOutput SideAC Grid Connection Type Three phases (Δ / Υ) Three phases (Δ) Three phases (Δ / Υ) Three phases (Δ)Rated AC Power (Pac,r) 165 kW 165 kW 220 kW 220 kWRated Grid Voltage (Vac,r) 400 V 320 V 400 V 320 VAC Voltage Range (Vacmin...Vacmax) 320...480 V (1) 256...368 V (1) 320...480 V (1) 256...368 V (1)

Maximum Output Current (Iac,max) 240 A 300 A 320 A 400 ARated Frequency (fr) 50/60 Hz 50/60 HzFrequency Range (fmin...fmax) 47...53 / 57...63 Hz (2) 47...53 / 57...63 Hz (2)

Power Factor (Cosphiac,r) > 0.995 (adj. ± 0.90) (3) > 0.995 (adj. ± 0.90) (3)

Total Harmonic Distortion < 3% (@ Pac,r) < 3% (@ Pac,r)AC Connection Type 1 x 185 mm2 (M10) 2 x 300 mm2 (M12) 1 x 185 mm2 (M10) 2 x 300 mm2 (M12)Output ProtectionAnti-Islanding Protection According to local standard According to local standardOutput Overvoltage Protection (Varistor) Yes, Class II Yes, Class IINight Time Disconnect Yes YesAC Circuit Breaker 50 kA 50 kAOperating PerformanceMaximum Efficiency (ηmax) 96.50% 98.00% 96.50% 98.00%Weithted Efficiency (ηEURO / ηCEC) 95.3% / 96.0% 97.7% / 98.0% 95.3% / 96.0% 97.7% / 98.0%Stand-by Consumption/Night-time power loss < 31 W < 26 W < 28 W < 33 WAC Auxiliary Supply 3 x 400 Vac +N, 50/60 Hz 3 x 400 Vac +N, 50/60 HzAuxiliary Supply Consumption < 0.30% of Pac,r < 0.24% of Pac,r < 0.28% of Pac,r < 0.24% of Pac,r

Auxiliary Supply Consumption without Cooling < 0.23% of Pac,r < 0.22% of Pac,r < 0.22% of Pac,r < 0.22% of Pac,r

Inverter Switching Frequency 18 kHz 18 kHzCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.) PVI-USB-RS485_232 (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)AURORA String Combiner PVI-STRINGCOMB (opt.) PVI-STRINGCOMB (opt.)User Interface 16 characters x 2 line LCD display for each module 16 characters x 2 line LCD display for each moduleEnvironmental

Ambient Temperature Range -10...+ 60°C/+14...140°F with derating above 50°C/122°F

-10...+ 60°C/+14...140°F with derating above 50°C/122°F

Relative Humidity 0...95% non condensing 0...95% non condensingNoise Emission < 68 db (A) @ 1 m < 66 db (A) @ 1 m < 72 db (A) @ 1 m < 69 db (A) @ 1 mMaximum Operating Altitude without Derating 1000 m / 3280 ft 1000 m / 3280 ftPhysical Environmental Protection Rating IP 20 IP 20Cooling Air Forced Air ForcedRequired Air Cooling Flow 4000 m3/h - 2360 CFM 3200 m3/h - 1888 CFM 4800 m3/h - 2832 CFM 4000 m3/h - 2360 CFM

Dimension (H x W x D) 2184mm x 1250mm x 850mm / 86.0” x 49.2” x 33.5”

1675mm x 1250mm x 850mm / 65,9” x 49,2” x 33.5”

2184mm x 1250mm x 850mm / 86.0” x 49.2” x 33.5”

1675mm x 1250mm x 850mm / 65,9” x 42,9” x 33.5”

Weight < 1200 kg / 2646 lb < 680 kg / 1500 lb < 1300 kg / 2867 lb < 780 kg / 1720 lbWeight of the module < 60 kg / 132 lb < 60 kg / 132 lbSafetyTransformer Yes No Yes NoMarking CE CE

Safety and EMC Standard EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12

EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12

Grid Standard Enel Guideline, BDEW, RD 1663 Enel Guideline, BDEW, RD 1663

1. The AC voltage range may vary depending on specific country grid standard

2. The Frequency range may vary depending on specific country grid standard

3. Power factor variations beyond ±0.9 imply a reduction of the active power

Page 82: Renewable Energy Solutios

PVI-275.0 / PVI-275.0-TLPVI-330.0 / PVI-330.0-TL

GENERAL SPECIFICATIONSCENTRALIZED MODELS

PVI-275.0PVI-275.0-TLPVI-330.0PVI-330.0-TL

82 AURORA PLUS

PVI-275.0 / PVI-275.0-TLPVI-330.0 / PVI-330.0-TL

PVI-55.0/330.0-TL PVI-275.0/330.0

90,00

91,00

92,00

93,00

94,00

95,00

96,00

97,00

98,00

99,00

100,00

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

[%

]

Pac / Pnom [%]

485Vdc

500Vdc

550Vdc

90,00

91,00

92,00

93,00

94,00

95,00

96,00

97,00

98,00

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

[%

]

Pac / Pnom [%]

485Vdc

500Vdc

550Vdc

Effi ciency Curves

Page 83: Renewable Energy Solutios

83AURORA PLUS

PARAMETER PVI-275.0 PVI-275.0-TL PVI-330.0 PVI-330.0-TL

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 1000 V 1000 VMPPT Input DC Voltage Range (VMPPTmin,r ... VMPPTmax,r) 485...950 V 485...950 VMPPT Input DC Range (VMPPTmin,f ... VMPPTmax,f) at Full Power 485...850 V 485...850 VNumber of Independent MPPT Multi-Master 5 6Number of Independent MPPT Multi - Master/Slave 3 3Number of Independent MPPT Master/Slave 1 1Maximum Combined DC Input Current (Idcmaxc) 620 A 744 AMaximum DC Input Current for Each Module (Idcmax,m) 124 A 124 ANumber of DC Inputs Pairs 5 6DC Connection Type 3x185mm2 (M10) +2x300mm2 (M12) 3x185mm2 (M10) +3x300mm2 (M12)Input ProtectionReverse Polarity Protection YES, with series diode YES, with series diodeInput Over Voltage Protection - Varistor 2 for each input pair, Class II 2 for each input pair, Class IIPhotovoltaic Array Isolation Control According to local standard According to local standardFuse Size for Each Input Pair 125 A / 1000 V 125 A / 1000 VOutput SideAC Grid Connection Type Three phases (Δ / Υ) Three phases (Δ) Three phases (Δ / Υ) Three phases (Δ)Rated AC Power (Pac,r) 275 kW 330 kWRated Grid Voltage (Vac,r) 400 V 320 V 400 V 320 VAC Voltage Range (Vacmin...Vacmax) 320...480 V (1) 256...368 V (1) 320...480 V (1) 256...368 V (1)

Maximum Output Current (Iac,max) 400 A 500 A 480 A 600 ARated Frequency (fr) 50/60 Hz 50/60 HzFrequency Range (fmin...fmax) 47...53 / 57...63 Hz (2) 47...53 / 57...63 Hz (2)

Power Factor (Cosphiac,r) > 0.995 (adj. ± 0.90) (3) > 0.995 (adj. ± 0.90) (3)

Total Harmonic Distortion < 3% (@ Pac,r) < 3% (@ Pac,r)AC Connection Type 1 x 240 mm2 (M12) 2 x 300 mm2 (M12) 1 x 240 mm2 (M12) 2 x 300 mm2 (M12)Output ProtectionAnti-Islanding Protection According to local standard According to local standardOutput Overvoltage Protection (Varistor) Yes, Class II Yes, Class IINight Time Disconnect Yes YesAC Circuit Breaker 50 kA 50 kAOperating PerformanceMaximum Effi ciency (ηmax) 96.70% 98.00% 96.70% 98.00%Weithted Effi ciency (ηEURO / ηCEC) 96.5% / 96.0% 97.7% / 98.0% 96.5% / 96.0% 97.7% / 98.0%Stand-by Consumption/Night-time power loss < 45 W < 40 W < 52 W < 47 WAC Auxiliary Supply 3 x 400 Vac +N, 50/60 Hz 3 x 400 Vac +N, 50/60 HzAuxiliary Supply Consumption < 0.29% of Pac,r < 0.24% of Pac,r < 0.28% of Pac,r < 0.24% of Pac,r

Auxiliary Supply Consumption without Cooling < 0.22% of Pac,r < 0.22% of Pac,r < 0.22% of Pac,r < 0.22% of Pac,r

Inverter Switching Frequency 18 kHz 18 kHzCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.) PVI-USB-RS485_232 (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)AURORA String Combiner PVI-STRINGCOMB (opt.) PVI-STRINGCOMB (opt.)User Interface 16 characters x 2 line LCD display for each module 16 characters x 2 line LCD display for each moduleEnvironmental

Ambient Temperature Range -10...+ 60°C/+14...140°F with derating above 50°C/122°F

-10...+ 60°C/+14...140°F with derating above 50°C/122°F

Relative Humidity 0...95% non condensing 0...95% non condensingNoise Emission < 75 db (A) @ 1 m < 72 db (A) @ 1 m < 78 db (A) @ 1 m < 75 db (A) @ 1 mMaximum Operating Altitude without Derating 1000 m / 3280 ft 1000 m / 3280 ftPhysical Environmental Protection Rating IP 20 IP 20Cooling Air Forced Air ForcedRequired Air Cooling Flow 6800 m3/h - 4012 CFM 4800 m3/h - 2832 CFM 7600 m3/h - 4484 CFM 5600 m3/h - 3304 CFM

Dimension (H x W x D)

2184mm x 1250mm x 850mm / 86.0” x 49.2” x 33.5”

1215mm x 1250mm x 870mm / 47.8” x 49.2” x 34.3” (Transf.)

2184mm x 1250mm x 850mm / 86.0” x 49.2” x 33.5”

2184mm x 1250mm x 850mm / 86.0” x 49.2” x 33.5”

1215mm x 1250mm x 870mm / 47.8” x 49.2” x 34.3” (Transf.)

2184mm x 1250mm x 850mm / 86.0” x 49.2” x 33.5”

Weight < 1600 kg / 3527 lb < 1000 kg / 2205 lb < 1750 kg / 3858 lb < 1150 kg / 2535 lbWeight of the module < 60 kg / 132 lb < 60 kg / 132 lbSafetyTransformer Yes No Yes NoMarking CE CE

Safety and EMC Standard EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12

EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12

Grid Standard Enel Guideline, BDEW, RD 1663 Enel Guideline, BDEW, RD 1663

1. The AC voltage range may vary depending on specifi c country grid standard2. The Frequency range may vary depending on specifi c country grid standard3. Power factor variations beyond ±0.9 imply a reduction of the active power

Page 84: Renewable Energy Solutios

PVI-CENTRAL-50PVI-CENTRAL-100

GENERAL SPECIFICATIONSCENTRALIZED MODELS

PVI-CENTRAL-50-US PVI-CENTRAL-100-US

84 AURORA PLUS

Page 85: Renewable Energy Solutios

FeaturesReduced susceptibility to a single fault. In case of a component failure, a maximum of 50kW will be lostReduced acoustic noise due to the high switching frequencyReverse-polarity protection minimizes potential damage caused by array mis-wiringMaximum input voltage up to 600Vdc, high design fl exibility and reduced DC distribution losses for large scale PV plantsIntegrated DC and AC distribution and protection. Fully equipped for connection, additional accessories not requiredEasy installation and maintenance procedure. Front extractable DC/AC converters andaccessibility to all critical partsHigh efficiencies deliver more energyTwo independent RS-485 communication interfaces - for inverter and intelligent string combiner monitoringIntegrated DC disconnect switch for each 50 kW module AC and DC side integrated protection (fuses and OVR) easily replaceableIntegrated fuse grounding kit with ground-fault detection and interruption (GFDI) compliant to UL1741

••••••••••

These Aurora commercial-grade inverters are designed for large solar applications such as apartment buildings and industrial facilities. These extremely scalable modular invertersystems, based on 50kW conversion modules, increase usable power and improve availability.

The reduction of performance in any individual inverter will not impact the energy-harvesting capabilities of other modules.

Industry-leading power conversion efficiencies of up to 95.8%, combined with high-speed Maximum Power Point Tracking (MPPT) channels, optimize energy harvesting across a wide array of operating conditions. Inverter systems are delivered pre-configured and pre-tested, significantly reducing on-site wiring and testing.

85AURORA PLUS

LITE

PLUS

ULTR

A

Page 86: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

86 AURORA PLUS

PVI-CENTRAL-50 PVI-CENTRAL-100

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

% of Rated Output Power

Effi

cien

cy, %

330 Vdc

370 Vdc

480 Vdc

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

% of Rated Output Power

Effi

cien

cy, %

330 Vdc

370 Vdc

480 Vdc

BLOCK DIAGRAM OF PVI-CENTRAL-100 WITH TRANSFORMER FOR NORTH AMERICA

PV ARRAY 1 (+)

PV ARRAY 1 (-)

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

INVERTER MODULE 50kW

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

INVERTER MODULE 50kW

ACCONTACTOR

AC MAGNETICBREAKER

EXTERNAL GRID INTERFACE-

NIGHT CONTROL

208 Vac or 480 Vac60 Hz, 3 Ph

100kVATRANSFORMER

PE

PE

PE

L1

L2

L3

PV ARRAY 2 (+)

PV ARRAY 2 (-)

(1) if -PG version fuses are on negative polarity.

(1)

(1)

Page 87: Renewable Energy Solutios

87AURORA PLUS

PARAMETER PVI-CENTRAL-50-US-208

PVI-CENTRAL-100-US-208

PVI-CENTRAL-50-US-480

PVI-CENTRAL-100-US-480

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 600 V 600 VMPPT Input DC Voltage Range (VMPPTmin,r ... VMPPTmax,r) 330...600 V 330...600 VMPPT Input DC Range (VMPPTmin,f ... VMPPTmax,f) at Full Power 330...600 V 330...600 VNumber of Independent MPPT Master/Slave 1 1Maximum Combined DC Input Current (Idcmaxc) 170 A 340 A 170 A 340 AMaximum DC Input Current for Each Module (Idcmax,m) 170 A 170 ANumber of DC Inputs Pairs 1 2 1 2DC Connection Type 2 x 3/0 AWG 90° / M10 4 x 3/0 AWG 90° / M10 2 x 3/0 AWG 90° / M10 4 x 3/0 AWG 90° / M10Input ProtectionReverse Polarity Protection Yes, with series diode Yes, with series diodeInput Over Voltage Protection - Varistor Yes YesPhotovoltaic Array Isolation Control GFDI (1), According to UL 1741 GFDI (1), According to UL 1741Fuse Size for Each Input Pair 200A / 600V 200A / 600VOutput SideAC Grid Connection Type Three phases (Δ) Three phases (Δ)Rated AC Power (Pac,r) 50 kW 100 kW 50 kW 100 kWRated Grid Voltage (Vac,r) 208 V 208 V 480 V 480 VAC Voltage Range (Vacmin...Vacmax) 183...228 V 183...228 V 422...528 V 422...528 VMaximum Output Current (Iac,max) 139 A 278 A 61 A 121 ARated Frequency (fr) 60 Hz 60 HzFrequency Range (fmin...fmax) 59.3...60.5 Hz 59.3...60.5 HzPower Factor (Cosphiac,r) > 0.995 > 0.995Total Harmonic Distortion < 4% (@ Pac,r) < 3% (@ Pac,r)AC Connection Type 3 x 2/0 AWG 90° / M10 3 x 2/0 AWG 90° / M10Output ProtectionAnti-Islanding Protection According to UL 1741 According to UL 1741Output Overvoltage Protection (Varistor) Yes YesNight Time Disconnect Yes YesAC Circuit Breaker Yes / 65 kA Yes / 65 kAOperating PerformanceMaximum Efficiency (ηmax) 95.6% 95.8%Weithted Efficiency (ηEURO / ηCEC) - / 95.0% - / 95.0%Stand-by Consumption/Night-time power loss < 15 W < 30 W < 15 W < 30 WAC Auxiliary Supply 3 x 480 Vac, 50/60 Hz 3 x 480 Vac, 50/60 HzAuxiliary Supply Consumption < 0.40% of Pac,r < 0.40% of Pac,r

Inverter Switching Frequency 18 kHz 18 kHzCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.) PVI-USB-RS485_232 (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)AURORA String Combiner PVI-STRINGCOMB (opt.) PVI-STRINGCOMB (opt.)User Interface 16 characters x 2 lines LCD display for each module 16 characters x 2 lines LCD display for each moduleEnvironmental

Ambient Temperature Range -10...+50°C/+14...122°F with derating above 40°C/104°F

-10...+50°C/+14...122°F with derating above 40°C/104°F

Relative Humidity 0...95 % non condensing 0...95 % non condensingNoise Emission < 62 dB @ 1 m < 62 dB @ 1 mMaximum Operating Altitude without Derating 1000 m / 3280 ft 1000 m / 3280 ftPhysical Environmental Protection Rating Nema 1 Nema 1Cooling Air forced Air forcedRequired Air Cooling Flow 1500 m3/h - 885 CFM 2000 m3/h - 1180 CFM 1500 m3/h - 885 CFM 2000 m3/h - 1180 CFM

Dimension (H x W x D) 1275mm x 1675mm x 850mm / 50.2” x 66.0” x 33.5”

1275mm x 1675mm x 850mm / 50.2” x 66.0” x 33.5”

1275mm x 1675mm x 850mm / 50.2” x 66.0” x 33.5”

1275mm x 1675mm x 850mm / 50.2” x 66.0” x 33.5”

Weight 700 kg / 1550 lb 850 kg / 1873 lb 700 kg / 1550 lb 850 kg / 1873 lbWeight of the module < 70 kg / 154 lb < 70 kg / 154 lbSafetyTransformer Yes YesMarking cCSAus cCSAusSafety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01 UL 1741, CSA - C22.2 N. 107.1-01Grid Standard IEEE 1547 IEEE 1547

1. Ground Fault Detector Interrupter

Page 88: Renewable Energy Solutios

88 AURORA PLUS

PVI-CENTRAL-250PVI-CENTRAL-300

GENERAL SPECIFICATIONSCENTRALIZED MODELS

PVI-CENTRAL-250-USPVI-CENTRAL-300-US

PVI-CENTRAL-250-CANPVI-CENTRAL-300-CAN

Page 89: Renewable Energy Solutios

FeaturesFeaturesReduced susceptibility to a single fault. In case of a component failure, a maximum of 50kW will be lostReduced acoustic noise due to the high switching frequencyOutdoor enclosure for unrestricted use under any environmental conditionsMaximum input voltage up to 600Vdc, high design fl exibility and reduced DC distribution losses for large scale PV plantsIntegrated DC and AC distribution and protection. Fully equipped for connection, additional accessories not requiredEasy installation and maintenance procedure. Front extractible DC/AC converters and accessibility to all critical partsTwo independent RS-485 communication interfaces - for inverter and intelligent string combiner monitoringHigh efficiency LV isolation transformerIntegrated DC disconnect switch for each 50 kW module AC and DC side integrated protection (fuses and OVR) easily replaceableIntegrated fuse grounding kit with ground-fault detection and interruption (GFDI) compliant to UL174

••••••••••

These Aurora commercial-grade inverters are designed for large solar applications such as apartment buildings and industrial facilities. These extremely scalable modular invertersystems, based on 50kW conversion modules, increase usable power and improve availability.

The reduction of performance in any individual inverter will not impact the energy-harvesting capabilities of other modules.

Industry-leading power conversion efficiencies of up to 97.6%, combined with high-speed Maximum Power Point Tracking (MPPT) channels, optimize energy harvesting across a wide array of operating conditions. Inverter systems are delivered pre-configured and pre-tested in rugged enclosures, significantly reducing on-site wiring and testing.

Three independent MPPT input channels off er maximum fl exibility and energy harvesting.

89AURORA PLUS

FeaturesLI

TEPL

USUL

TRA

Page 90: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

90 AURORA PLUS

BLOCK DIAGRAM OF PVI-CENTRAL-300 WITH TRANSFORMER FOR NORTH AMERICA

90 AURORA PLUS

PVI-CENTRAL-250-US PVI-CENTRAL-300-US

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

320 Vac

360 Vac

480 Vac

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

320 Vac

360 Vac

480 Vac

ACCONTACTOR

AC BREAKER

300kVATRANSFORMER

RST

REVERSE POLARITYPROTECTION DC

FUSEDC

BREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

INVERTER MODULE 50kW

INVERTER MODULE 50kW

PE

PE

PV ARRAY 1 (+)

PV ARRAY 1 (-)

PV ARRAY 2 (+)

PV ARRAY 2 (-)

GROUND FAULTDETECTION

REMOTEOFF

POSITIVEGROUNDING

OPTION

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

INVERTER MODULE 50kW

INVERTER MODULE 50kW

PE

PE

PV ARRAY 1 (+)

PV ARRAY 1 (-)

PV ARRAY 2 (+)

PV ARRAY 2 (-)POSITIVE

GROUNDINGOPTION

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

INVERTER MODULE 50kW

INVERTER MODULE 50kW

PE

PE

PV ARRAY 1 (+)

PV ARRAY 1 (-)

PV ARRAY 2 (+)

PV ARRAY 2 (-)POSITIVE

GROUNDINGOPTION

MAIN AC POWERCONNECTION

PE

+ 24VDC

POWERSUPPLY24 VDC

480VAC

208VAC

480VAC

NLS3LS2LS1

208 VACCONTROL CIRCUIT

AC BREAKER

RST

PE

AUX POWERCONNECTION

GROUND FAULTDETECTION

REMOTEOFF

GROUND FAFAF UGROUND FAULTDETECTION

GROUND FAULTDETECTION

REMOTEOFF

(1) if -PG version fuses are on negative polarity.

(1)

(1)

(1)

(1)

(1)

(1)

Page 91: Renewable Energy Solutios

91AURORA PLUS

PARAMETER PVI-CENTRAL-250-US

PVI-CENTRAL-300-US

PVI-CENTRAL-250-CAN

PVI-CENTRAL-300-CAN

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 600 V 600 VMPPT Input DC Voltage Range (VMPPTmin,r ... VMPPTmax,r) 320...600 V 320...600 VMPPT Input DC Range (VMPPTmin,f ... VMPPTmax,f) at Full Power 320...550 V 320...550 VNumber of Independent MPPT Multi - Master/Slave 3 3Maximum Combined DC Input Current (Idcmaxc) 850 A 1020 A 850 A 1020 AMaximum DC Input Current for Each Module (Idcmax,m) 170 A 170 ANumber of DC Inputs Pairs 5 6 5 6DC Connection Type 10 x 350 kcmil 90° / M10 12 x 350 kcmil 90° / M10 10 x 350 kcmil 90° / M10 12 x 350 kcmil 90° / M10Input ProtectionReverse Polarity Protection YES, with series diode YES, with series diodeInput Over Voltage Protection - Varistor Yes YesPhotovoltaic Array Isolation Control GFDI (1), According to UL 1741 GFDI (1), According to UL 1741Fuse Size for Each Input Pair 200A / 600V 200A / 600VOutput SideAC Grid Connection Type Three phases (Δ) Three phases (Δ)Rated AC Power (Pac,r) 250 kW 300 kW 250 kW 300 kWRated Grid Voltage (Vac,r) 480 V 480 V 600 V 600 VAC Voltage Range (Vacmin...Vacmax) 423...528 V 528...660 VMaximum Output Current (Iac,max) 315 A 378 A 253 A 303 ARated Frequency (fr) 60 Hz 60 HzFrequency Range (fmin...fmax) 59.3...60.5 Hz 59.3...60.5 HzPower Factor (Cosphiac,r) > 0.995 > 0.995Total Harmonic Distortion < 3% (@ Pac,r) < 3% (@ Pac,r)AC Connection Type 3 x 350 kcmil 90° / M10 3 x 350 kcmil 90° / M10Output ProtectionAnti-Islanding Protection According to UL 1741 According to UL 1741Output Overvoltage Protection (Varistor) Yes YesNight Time Disconnect Yes YesAC Circuit Breaker Yes / 65 kA Yes / 65 kAOperating PerformanceMaximum Efficiency (ηmax) 97.6% 97.6%Weithted Efficiency (ηEURO / ηCEC) 97.6 / 97.2% 97.6 / 97.2%Stand-by Consumption/Night-time power loss < 105 W < 120 W < 105 W < 120 WAC Auxiliary Supply 3 x 480 Vac, 50/60 Hz 3 x 480 Vac, 50/60 HzAuxiliary Supply Consumption < 0.30% of Pac,r < 0.35% of Pac,r < 0.30% of Pac,r < 0.35% of Pac,r

Inverter Switching Frequency 9 kHz 9 kHzCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.) PVI-USB-RS485_232 (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)AURORA String Combiner PVI-STRINGCOMB (opt.) PVI-STRINGCOMB (opt.)User Interface TFT LCD 5.7” TFT LCD 5.7”Environmental

Ambient Temperature Range -25...+60 °C / -13...+140°F with derating above 50°C / 122°F

-25...+60 °C / -13...+140°F with derating above 50°C / 122°F

Relative Humidity 0...100 % condensing 0...100 % condensingNoise Emission < 62 dB @ 1 m < 62 dB @ 1 mMaximum Operating Altitude without Derating 1000 m / 3280 ft 1000 m / 3280 ftPhysical Environmental Protection Rating Nema 3R Nema 3RCooling Air forced Air forcedRequired Air Cooling Flow 7000 m3/h - 4130 CFM 8000 m3/h - 4720 CFM 7000 m3/h 8000 m3/hDimension (H x W x D) 2147mm x 2933mm x 1250mm / 84.5” x 115.7” x 49”.3 2147mm x 2933mm x 1250mm / 84.5” x 115.7” x 49”.3Weight < 2495 kg / 5500 lb 2722 kg / 6000 lb < 2495 kg / 5500 lb 2722 kg / 6000 lbWeight of the module < 70 kg / 154 lb < 70 kg / 154 lbSafetyTransformer Yes YesMarking cCSAus cCSAusSafety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01 UL 1741, CSA - C22.2 N. 107.1-01Grid Standard IEEE 1547 IEEE 1547

1. Ground Fault Detector Interrupter

Page 92: Renewable Energy Solutios

92 AURORA PLUS

Page 93: Renewable Energy Solutios

ULTRA

93AURORA PLUS

LITE

PLUS

ULTR

A

Page 94: Renewable Energy Solutios

ULTRA

GENERAL SPECIFICATIONSCENTRALIZED MODELS

ULTRA-700.0-TLULTRA-1050.0-TLULTRA-1400.0-TL

94 AURORA PLUS

NEW

Page 95: Renewable Energy Solutios

Features

95AURORA PLUS

High performance utility grade inverter for large utility PV installations with 98.7% efficiencyOutdoor enclosure for unrestricted use under any environmental conditionsPassive liquid cooling with total segregation of internal compartments assuring a 5-year maintenance cycleReduced susceptibility to a single fault. In case of a component failure, a maximum of 350kW will be lostExtended MPPT input voltage rangeDirect transformerless conversion to the 690 Vac output reduces AC distribution costMaximum input voltage up to 1100 Vdc, high design fl exibility and reduced DC distribution losses for large scale PV plantsIntegrated DC and AC distribution and protection. Fully equipped for connection, additional accessories not requiredEasy installation and maintenance procedure. Front extractible DC/AC converters and accessibility to all critical partsEthernet communication and two independent RS-485 communication interfaces for inverter and intelligent string combiner monitoringCompliant to BDEW and FERC 661

•••••••••••

The largest solar power inverter in the Power-One Aurora product range, the new Ultra 1.4MW unit is designed with large utility-grade installations in mind.

This liquid-cooled, high-powered Aurora inverter is the largest PV inverter available in the market. The compact chassis gives maximum power for the minimum footprint.

Industry-leading power conversion efficiencies of up to 98.7%, combined with high-speed Maximum Power Point Tracking (MPPT) channels, optimize energy harvesting across a wide array of operating conditions. Up to four independent MPPT input channels off er maximum fl exibility and energy harvesting.

This large inverter system signifi cantly reduces the wiring requirements and on-site testing thanks to the presence of separated and dedicated compartments for DC and AC.

LITE

PLUS

ULTR

A

Page 96: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

96 AURORA PLUS

PVI-ULTRA

94,5%

95,0%

95,5%

96,0%

96,5%

97,0%

97,5%

98,0%

98,5%

99,0%

650 Vdc

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

BLOCK DIAGRAM OF ULTRA-1400.0-TL

RST

MAIN AC POWERCONNECTION

PE

±24 VDC

±24 VDC

- 5 VDC

LS3 NLS2LS1

208 VACCONTROL CIRCUIT

AC BREAKER

RSTN

PE

AUX POWERCONNECTION

TO EACH 350.0 Kw MODULE

DCBREAKER

OVR

CONTROL CIRCUIT

ACFUSE

EMIFILTER

ACFUSE

EMIFILTER

ACFUSE

EMIFILTER

ACFUSE

EMIFILTER

DCBREAKER

OVR

INVERTER MODULE 350kW

DCBREAKER

OVR

DCBREAKER

OVR

CONTROL CIRCUIT

INVERTER MODULE 350kW

CONTROL CIRCUIT

INVERTER MODULE 350kW

CONTROL CIRCUIT

INVERTER MODULE 350kW

LINEFILTER

MODULE

ACCONTACTMODULE

BULKCAPS

MODULE

DC / ACINVERTERMODULE

LINEFILTER

MODULE

ACCONTACTMODULE

BULKCAPS

MODULE

DC / ACINVERTERMODULE

LINEFILTER

MODULE

ACCONTACTMODULE

BULKCAPS

MODULE

DC / ACINVERTERMODULE

LINEFILTER

MODULE

ACCONTACTMODULE

BULKCAPS

MODULE

DC / ACINVERTERMODULE

AC BREAKER

PV ARRAY 1(+)

PV ARRAY 2(+)

PV ARRAY 4(+)

PV ARRAY 5(+)

PV ARRAY 6(+)

PV ARRAY 3(+)

PV ARRAY 1(-)

PV ARRAY 2(-)

PV ARRAY 4(-)

PV ARRAY 5(-)

PV ARRAY 6(-)

PV ARRAY 3(-)

••••••

••••••

PV ARRAY 19(+)

PV ARRAY 20(+)

PV ARRAY 22(+)

PV ARRAY 23(+)

PV ARRAY 24(+)

PV ARRAY 21(+)

PV ARRAY 19(-)

PV ARRAY 20(-)

PV ARRAY 22(-)

PV ARRAY 23(-)

PV ARRAY 24(-)

PV ARRAY 21(-)

Page 97: Renewable Energy Solutios

97AURORA PLUS

PARAMETER ULTRA-700.0-TL-OUTD-690

ULTRA-1050.0-TL-OUTD-690

ULTRA-1400.0-TL-OUTD-690

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 1100 VMPPT Input DC Voltage Range (VMPPTmin,r ... VMPPTmax,r) 470...1000VMPPT Input DC Range (VMPPTmin,f ... VMPPTmax,f) at Full Power 550...900 VNumber of Independent MPPT Multi-Master 2 3 4Number of Independent MPPT Multi - Master/Slave 1 2 2Maximum Combined DC Input Current (Idcmaxc) 1240 A 1240 A + 620 A 1640 A + 1640 AMaximum DC Input Current for Each Module (Idcmax,m) 620 ANumber of DC Inputs Pairs 12 18 24DC Connection Type 12 x 50mm2 (M8)...185mm2(M10) 18 x 50mm2 (M8)...185mm2(M10) 24 x 50mm2 (M8)...185mm2(M10)Input ProtectionReverse Polarity Protection Yes, via input breakerInput Over Voltage Protection - Varistor 2 for each modulePhotovoltaic Array Isolation Control According to local standardFuse Size for Each Input Pair 125 A / 1100 V Output SideAC Grid Connection Type Three phases (Δ)Rated AC Power (Pac,r) 700 kW 1050 kW 1400 kWRated Grid Voltage (Vac,r) 690 VAC Voltage Range (Vacmin...Vacmax) 621...759 V (1)

Maximum Output Current (Iac,max) 584 A 876 A 1168 ARated Frequency (fr) 50/60 HzFrequency Range (fmin...fmax) 47...53 / 57...63 Hz (2)

Power Factor (Cosphiac,r) > 0.995 (adj. ± 0.90) (3)

Total Harmonic Distortion < 3% (@ Pac,r)AC Connection Type 2 x 240 mm2 (M12) 3 x 240 mm2 (M12) 4 x 240 mm2 (M12)Output ProtectionAnti-Islanding Protection According to local standardOutput Overvoltage Protection (Varistor) YesNight Time Disconnect YesAC Switch YesAC Fuse for each module 3x350AOperating PerformanceMaximum Efficiency (ηmax) 98.7% 98.7% 98.7%Weithted Efficiency (ηEURO / ηCEC) 98.2% / 98.0% 98.2% / 98.0% 98.2% / 98.0%Stand-by Consumption/Night-time power loss < 90 W < 135 W < 180 WAC Auxiliary Supply 3 x 400 Vac +N, 50/60 Hz 3 x 400 Vac +N, 50/60 Hz 3 x 400 Vac +N, 50/60 HzAuxiliary Supply Consumption < 0.65% of Pac,r < 0.50% of Pac,r < 0.65% of Pac,r

Auxiliary Supply Consumption without Cooling < 0.08% of Pac,r < 0.08% of Pac,r < 0.08% of Pac,r

Inverter Switching Frequency 7,5 KHz 7,5 KHz 7,5 KHzCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)AURORA String Combiner PVI-STRINGCOMB (opt.)User Interface TFT LCD 5.7”Environmental

Ambient Temperature Range -20...+ 60°C/-4...140°F with derating above 50°C/122°F -40...+ 60°C/-40...140°F with derating above 50°C/122°F (opt.)

Relative Humidity 0...100% condensingNoise Emission < 78 dB(A) @ 1 m Maximum Operating Altitude without Derating 1000 m / 3280 ftPhysical Environmental Protection Rating IP 65Cooling Passive liquid and air forcedRequired Air Cooling Flow Not applicable

Dimension (H x W x D) 2938mm x 3000mm x 1520mm / 115.7 “ x 118.1” x 59.9”

2938mm x 3700mm x 1520mm / 115.7 “ x 145.7” x 59.9”

2938mm x 4400mm x 1520mm / 115.7 “ x 173.2” x 59.9”

Weight < 2000 kg / 4409 lb < 2500 kg / 5521 lb < 3500 kg / 7716 lbWeight of the module < 55 kg / 121 lbSafetyTransformer NoMarking CESafety and EMC Standard EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12Grid Standard Enel Guideline, BDEW, FERC 661

1. The AC voltage range may vary depending on specific country grid standard2. The Frequency range may vary depending on specific country grid standard3. Power factor variations beyond ±0.9 imply a reduction of the active power

Page 98: Renewable Energy Solutios

98 AURORA STATION

Page 99: Renewable Energy Solutios

STATIONST

ATIO

N

99AURORA STATION

Page 100: Renewable Energy Solutios

PVI-STATION

100 AURORA STATION

Turnkey solution for PV plantsRated power between 440kW and 1.3 MWVery compact designBest in class efficiency thanks to the use of new generation Power-One inverters and mineral liquid insulated MV transformersMaximum fl exibility thanks to the diff erent inverter size and technology

••••

Power-One’s turnkey solution allows large installation customers to select their power inverter solution to be custom-fitted into a prefabricated weatherproof cabin to allow for simple and speedy installation in the field. There are many tailor-made options available for rated power between 440kW and 1.3 MW.

The major benefit of this product is the high power-low space ratio and its ability to configure to specific customer requirements such as multiple MPPTs.

This product maximizes efficiencies and reliability by using the new Aurora Central inverters, liquid filled MV transformers. The modular format of the Aurora central inverters along with a unique easy-out, easy-in rack system allows for simple maintenance in all weather conditions.

Features

Page 101: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

101AURORA PLUS

PVI-330.0-TL

90,00

91,00

92,00

93,00

94,00

95,00

96,00

97,00

98,00

99,00

100,00

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

[%

]

Pac / Pnom [%]

485Vdc

500Vdc

550Vdc

STANDARD STATION FOR NORTH AMERICA(MULTI-MASTER CONFIGURATION WITH FLOATING ARRAY)

STANDARD STATION FOR NORTH AMERICA(MULTI-MASTER CONFIGURATION WITH FLOATING ARRAY)

PVI-330.0-TL

PM6

PM1

INV AUX1

PVI-330.0-TL

PM6

PM1

INV AUX2

PVI-330.0-TL

PM6

PM1

INV AUX3

L1

L2

L3

320 V / MEDIUM VOLTAGE

MV TRANSFORMER

TO GRID

PVI-330.0-TL

PM6

PM1

INV AUX1

PVI-330.0-TL

PM6

PM1

INV AUX4

PVI-330.0-TL

PM6

PM1

INV AUX2

L1

L2

L3

320 V / MEDIUM VOLTAGE

MV TRANSFORMER

TO GRID

PVI-330.0-TL

PM6

PM1

INV AUX3

Page 102: Renewable Energy Solutios

102 AURORA STATION

PARAMETER STATION-PLUS-440.0

STATION-PLUS-550.0

STATION-PLUS-660.0

STATION-PLUS-770.0

STATION-PLUS-880.0

STATION-PLUS-1000.0

STATION-PLUS-1100.0

STATION-PLUS-1210.0

STATION-PLUS-1320.0

STATION-LITE-500.0

STATION-LITE-1000.0

STATION-LITE-1500.0

STATION-LITE-2000.0

Inverter Type 2 x PVI-220.0-TL 1 x PVI-330.0-TL 1 x PVI-220.0-TL 2 x PVI-330.0-TL 1 x PVI-330.0-TL

2 x PVI-220.0-TL2 x PVI-330.0-TL 1 x PVI-220.0-TL 3 x PVI-330.0 2 x PVI-330.0-TL

2 x PVI-220.0-TL3 x PVI-330.0-TL 1 x PVI-220.0-TL 4 x PVI-330.0 1 x PVI-500.0-TL 2 x PVI-500.0-TL 3 x PVI-500.0-TL 4 x PVI-500.0-TL

Input SideMPPT Input range (VMPPTmax,r...VMPPTtmin,r) 475...950 V 475...950 V 475....900 VMPPT Input range (VMPPTmax,f-VMPPTmin,f) at full power 475...850 V 475...850 V 475....900 VAbsolute Maximum Input Voltage (Vmax,abs) 1000 V 1000 V 1000 VNumber of Independent MPPT Multi-Master 8 10 12 14 16 18 20 22 24 2 4 6 8Number of Independent MPPT Master/Slave 4 5 6 7 8 9 10 11 12 1 2 3 4Number of Independent MPPT Multi-Master/Slave 2 2 2 3 3 3 4 4 4 1 2 3 4Maximum Combined Input Current (Idcmax,c) 992 A 1240 A 1488 A 1736 A 1984 A 2214 A 2480 A 2728 A 2976 A 550 A 1100 A 1650 A 2200 ANumber of DC Inputs Pairs 8 10 12 14 16 18 20 22 24 5 10 15 20Available Products Variants-US version for North America - - - - - ● - - ● ● ● ● ●-IT version for Italy ● ● ● ● ● ● ● ● ● - - - --DE version for Germany ● ● ● ● ● ● ● ● ● - - - -Output Side Inverter Rated Power (Pac,r) 440 kW 550 kW 660 kW 770 kW 880 kW 990 kW 1100 kW 1210 kW 1320 kW 500 kW 1000 kW 1500 kW 2000 kW

Rated Output Voltage (Vac,r)-US version 3 x 4.16...35 kV 3 x 4.16...35 kV 3 x 4.16...35 kV-IT version 3 x 15...20 kV 3 x 15...20 kV --DE version 3 x 10...20 kV 3 x 10...20 kV -

Rated Frequency (fr) 50/60 Hz 50/60 Hz 50/60 HzNominal Power Factor (Cosphiac,r) > 0.995 (adj. ± 0.90) > 0.995 (adj. ± 0.90) > 0.995 (adj. ± 0.90)Operating Performance (Inverter)Maximum Efficiency (ηmax) 98.0% 98.0% 98.50%Weighted Efficiency (EURO) 97.7% 97.7% 98.20%Transformer

Type -US version - 3 Phase Pad-Mounted, Oil Filled Biodegradable 3 Phase Pad-Mounted, Oil Filled Biodegradable-IT/DE version 3 Phase, Oil Filled Mineral/Dry Type 3 Phase, Oil Filled Mineral/Dry Type -

Cooling Class-US version - KNAN KNAN-IT/DE version ONAN (for Oil Filled Fransformer), Air Cooled (for Dry Transformer) ONAN (for Oil Filled Fransformer), Air Cooled (for Dry Transformer) -

CommunicationLocal Monitoring System -US/IT/DE version 1 x RS-485 (inc.) 1 x RS-485 (inc.) 1 x RS 485 (inc.)Remote Control -US/IT/DE version PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)

SCADA System-US version Optional Optional Optional-IT/DE version - - -

Environmental

Ambient Temperature RangeInverter -10...+60°C/+14...140°F with derating above 50°C/122°F -10...+60°C/+14...140°F with derating above 50°C/122°F -20...+55°C/-4...131°F with derating above 45°C/113°F

Station -10...+60°C/+14...140°F -10...+60°C/+14...140°F ‘-20...+55°C/-4...131°F

Relative Humidity 0...95% non condensing 0...95% non condensing 0...95% non condensingMaximum Operating Altitude without Derating 1000 m / 3280 ft 1000 m / 3280 ft 1000 m / 3280 ft Physical

Construction-US version - Steel Frame with Aluminum Wall Skin and Standing Seam Roof Steel Frame with Aluminum Wall Skin and Standing Seam Roof-IT version Sandwich Frame and Standing Seam Roof or Vibrated Reinforced Concrete Sandwich Frame and Standing Seam Roof or Vibrated Reinforced Concrete --DE version Vibrated Reinforced Concrete Vibrated Reinforced Concrete -

Mounting-US version - Pad-Mount or Pier-Mount Pad-Mount or Pier-Mount-IT/DE version Concrete (Platform for Sandwich Type), Foundation Tank (for Concrete-Made Station) Concrete (Platform for Sandwich Type), Foundation Tank (for Concrete-Made Station) -

Environmental Protection Rating

-US version - NEMA 3R NEMA 3R-IT/DE version IP 54 IP 54 -

Standard

InverterCE

EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 Enel Guideline, BDEW, RD 1663

CE EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12

Enel Guideline, BDEW, RD 1663

CQC, CE EN 50178, EN 61000-6-2, EN 61000-6-4, IEC 62109-1

CNCA/CTS0004, GB/T 19943, IEC 62116

Page 103: Renewable Energy Solutios

103AURORA STATION

PARAMETER STATION-PLUS-440.0

STATION-PLUS-550.0

STATION-PLUS-660.0

STATION-PLUS-770.0

STATION-PLUS-880.0

STATION-PLUS-1000.0

STATION-PLUS-1100.0

STATION-PLUS-1210.0

STATION-PLUS-1320.0

STATION-LITE-500.0

STATION-LITE-1000.0

STATION-LITE-1500.0

STATION-LITE-2000.0

Inverter Type 2 x PVI-220.0-TL 1 x PVI-330.0-TL 1 x PVI-220.0-TL 2 x PVI-330.0-TL 1 x PVI-330.0-TL

2 x PVI-220.0-TL2 x PVI-330.0-TL 1 x PVI-220.0-TL 3 x PVI-330.0 2 x PVI-330.0-TL

2 x PVI-220.0-TL3 x PVI-330.0-TL 1 x PVI-220.0-TL 4 x PVI-330.0 1 x PVI-500.0-TL 2 x PVI-500.0-TL 3 x PVI-500.0-TL 4 x PVI-500.0-TL

Input SideMPPT Input range (VMPPTmax,r...VMPPTtmin,r) 475...950 V 475...950 V 475....900 VMPPT Input range (VMPPTmax,f-VMPPTmin,f) at full power 475...850 V 475...850 V 475....900 VAbsolute Maximum Input Voltage (Vmax,abs) 1000 V 1000 V 1000 VNumber of Independent MPPT Multi-Master 8 10 12 14 16 18 20 22 24 2 4 6 8Number of Independent MPPT Master/Slave 4 5 6 7 8 9 10 11 12 1 2 3 4Number of Independent MPPT Multi-Master/Slave 2 2 2 3 3 3 4 4 4 1 2 3 4Maximum Combined Input Current (Idcmax,c) 992 A 1240 A 1488 A 1736 A 1984 A 2214 A 2480 A 2728 A 2976 A 550 A 1100 A 1650 A 2200 ANumber of DC Inputs Pairs 8 10 12 14 16 18 20 22 24 5 10 15 20Available Products Variants-US version for North America - - - - - ● - - ● ● ● ● ●-IT version for Italy ● ● ● ● ● ● ● ● ● - - - --DE version for Germany ● ● ● ● ● ● ● ● ● - - - -Output Side Inverter Rated Power (Pac,r) 440 kW 550 kW 660 kW 770 kW 880 kW 990 kW 1100 kW 1210 kW 1320 kW 500 kW 1000 kW 1500 kW 2000 kW

Rated Output Voltage (Vac,r)-US version 3 x 4.16...35 kV 3 x 4.16...35 kV 3 x 4.16...35 kV-IT version 3 x 15...20 kV 3 x 15...20 kV --DE version 3 x 10...20 kV 3 x 10...20 kV -

Rated Frequency (fr) 50/60 Hz 50/60 Hz 50/60 HzNominal Power Factor (Cosphiac,r) > 0.995 (adj. ± 0.90) > 0.995 (adj. ± 0.90) > 0.995 (adj. ± 0.90)Operating Performance (Inverter)Maximum Efficiency (ηmax) 98.0% 98.0% 98.50%Weighted Efficiency (EURO) 97.7% 97.7% 98.20%Transformer

Type -US version - 3 Phase Pad-Mounted, Oil Filled Biodegradable 3 Phase Pad-Mounted, Oil Filled Biodegradable-IT/DE version 3 Phase, Oil Filled Mineral/Dry Type 3 Phase, Oil Filled Mineral/Dry Type -

Cooling Class-US version - KNAN KNAN-IT/DE version ONAN (for Oil Filled Fransformer), Air Cooled (for Dry Transformer) ONAN (for Oil Filled Fransformer), Air Cooled (for Dry Transformer) -

CommunicationLocal Monitoring System -US/IT/DE version 1 x RS-485 (inc.) 1 x RS-485 (inc.) 1 x RS 485 (inc.)Remote Control -US/IT/DE version PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)

SCADA System-US version Optional Optional Optional-IT/DE version - - -

Environmental

Ambient Temperature RangeInverter -10...+60°C/+14...140°F with derating above 50°C/122°F -10...+60°C/+14...140°F with derating above 50°C/122°F -20...+55°C/-4...131°F with derating above 45°C/113°F

Station -10...+60°C/+14...140°F -10...+60°C/+14...140°F ‘-20...+55°C/-4...131°F

Relative Humidity 0...95% non condensing 0...95% non condensing 0...95% non condensingMaximum Operating Altitude without Derating 1000 m / 3280 ft 1000 m / 3280 ft 1000 m / 3280 ft Physical

Construction-US version - Steel Frame with Aluminum Wall Skin and Standing Seam Roof Steel Frame with Aluminum Wall Skin and Standing Seam Roof-IT version Sandwich Frame and Standing Seam Roof or Vibrated Reinforced Concrete Sandwich Frame and Standing Seam Roof or Vibrated Reinforced Concrete --DE version Vibrated Reinforced Concrete Vibrated Reinforced Concrete -

Mounting-US version - Pad-Mount or Pier-Mount Pad-Mount or Pier-Mount-IT/DE version Concrete (Platform for Sandwich Type), Foundation Tank (for Concrete-Made Station) Concrete (Platform for Sandwich Type), Foundation Tank (for Concrete-Made Station) -

Environmental Protection Rating

-US version - NEMA 3R NEMA 3R-IT/DE version IP 54 IP 54 -

Standard

InverterCE

EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 Enel Guideline, BDEW, RD 1663

CE EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12

Enel Guideline, BDEW, RD 1663

CQC, CE EN 50178, EN 61000-6-2, EN 61000-6-4, IEC 62109-1

CNCA/CTS0004, GB/T 19943, IEC 62116

Page 104: Renewable Energy Solutios

104 AURORA VISION

Page 105: Renewable Energy Solutios

VISIONVI

SIO

N

105AURORA VISION

Page 106: Renewable Energy Solutios

106 AURORA VISION

AURORA VISION - Overview

Page 107: Renewable Energy Solutios

107AURORA VISION

The rules for managing solar electric power production turn traditional business operations on its head. Solar power plants are highly distributed, with each site generating far less power than a non-renewable power plant. In addition, plants are typically distributed over large geographic areas and may be managed by off -site staff .

Operating profit margins are narrow in the solar electric industry, and plants must operate at 98% upti-me and produce more than 95% of expected output. With these constraints, failures can be expensive. Small defects (string faults or panel soiling, for example) and inaccurate problem diagnosis can eat up an entire downtime budget or worse. Catastrophic failures, such as damaged inverters, could mean days or weeks offl ine. No plant operator can aff ord this type of exposure.

Maximum Uptime, Increased Return on Investment and Peace of Mind

In 2010, Power-One acquired the technology of leader remote monitoring provider for renewable energy systems Fat Spaniel Technologies.

All Power-One’s existing monitoring and control products and services now feature alongside the Fat Spaniel solutions to address renewable energy information needs. These combined products, services and solutions fall under the new category Aurora Vision. There is also an additional premium off ering called Fat Spaniel Prime Edition focused on advanced data analysis and visualization of performance across installations.

Aurora Vision has three key off erings: Software, Hardware and Accessories.

Aurora Vision software includes a full range of system fault management, diagnostics, asset tracking, performance index and alerting services to enable O&M service providers to maximize system energy output while minimizing costs.

Other digital services available include revenue information such as billing data, Renewable Energy Certificate (REC) reporting, performance-based incentive (PBI) reporting and XML data feeds.

Web-based energy production and conservation metrics, displayed via Internet-connected PCs and kiosks in high traffic areas, such as building lobbies or retail sites, provides an eff ective way to market clean energy.

The hardware section of Aurora Vision includes the equipment designed to capture data and environ-mental information to allow the transferral between inverter, installation and owner. A key product is the Aurora Universal which is installed at the PV plant. This section also includes inverter add-ons such as string-combiner boxes and the EVO easy control box.

Accessories include monitoring equipment such as the Desktop monitoring system and the EVO Easy Control.

Providing the complete panel to grid system solution is the key objective for Power-One. The Aurora Vision services will help maximize the return on investment of renewable energy projects through the better understanding and communication between the user and the installation.

Page 108: Renewable Energy Solutios

108 AURORA VISION

AURORA VISION

GENERAL SPECIFICATIONS

Features

Real Time Visibility - Aurora Vision provides highly interactive and real-time access to key performance and operations metrics to help plant management optimize operational decisions. Over 4,100 plants supporting an aggregate of 240 MW power generated use Aurora Vision for monitoring and management.

Scalable and Secure Platform - Field-tested, scalable and secure architecture supports over 10 million plant operations transactions per day and trusted by U.S. utility- and environmental regulatory agencies to enable prompt and accurate financial rebate processing.

Extensible & Modular Solution - Modular design enables extensibility of the platform to support Easy integration with Aurora Universal platform and other popular inverters to increase diagnostic capability, reduce non-compliance risk, and enable plant uptime of 98%+.

108 AURORA VISION

Page 109: Renewable Energy Solutios

109AURORA VISION

PARAMETER AURORA VISION EDITION FAT SPANIEL PRIME EDITION

PORTFOLIO DASHBOARD

Overview Portfolio level view of power, energy, plant status, and active events

Granularity Daily, weekly monthly and yearly summarization of key performance indicatorsASSET MANAGEMENTOverview Portfolio level view of assets by location, status (severity of active events) and system sizePlant Summary Operational level summary of each plant available as daily, weekly, month and yearly summaries

Asset Details Not applicableManage asset details, report generation, event log analysis and plant sharing capabilities at individual

plant level

EVENT MANAGEMENT

Overview Monitor and manage critical event data such as severity, plant, asset, type, duration, start, end, notify, acknowledge and notes

Profile Management System default profile only Unlimited profile generation and associate events and corresponding basic/advanced severity levels

REPORTING

Standard Reporting Export chart data to Excel View and export standard operational reports across the plant portfolio

Custom Reporting Not applicable Create, view and export custom operational reports across the plant portfolio

Agency Reporting Log of agency reports submitted by plant, by agency, by calendar periodANALYTICS

Overview Not applicable Perform advanced data analysis and visualization of performance across plants

Block Diagram

Page 110: Renewable Energy Solutios

110 AURORA VISION110 AURORA VISION

AURORA UNIVERSAL

GENERAL SPECIFICATIONS

110 AURORA VISION

NEW

Page 111: Renewable Energy Solutios

111AURORA VISION 111AURORA VISION

Features

The Aurora Universal System is a high-performance, customer-premises data management platform for renewable energy plant operations, revenue-grade metering, and smart grid integration. Aurora Universal interoperates with multi-vendor balance-of-system equipment including inverters, string combiners, meters, and environmental systems, delivering high-frequency/high-accuracy data sampling and high reliability. Together with Power-One’s Aurora Vision and Fat Spaniel Prime edition software-as-a-service management solutions, Aurora Universal helps simplify operational management and ensure availability of distributed power plants.

Aurora Universal models include:Aurora Universal Revenue Grade: for high-accuracy energy management and metering for power plants of up to 2 MW in capacity (or segments thereof )Aurora Universal Industrial: for continuous monitoring of popular string and central Inverter modelsAurora Universal Residential: for continuous monitoring of popular residential inverter models

Unified Interoperable PlatformA unified plant data management platform that seamlessly integrates balance-of-system components (inverters, string combiners, environmental systems) from Power-One and a wide-range of 3rd Party vendors. Provides out-of-box integration with Aurora Vision and Fat Spaniel Prime Software-as-a-Service solutions for fast installation and instant plant management.

High-Performance ArchitectureField-tested, scalable and secure architecture enables reliable real-time revenue-grade energy monitoring and management.

Extensible & Modular SolutionModular design enables extensibility of the platform to support wide range of multi-vendor devices and applications from residential to utility environments.

VISI

ON

111AURORA VISION

•••

Page 112: Renewable Energy Solutios

Block Diagram

112 AURORA VISION

Aurora Compute Platform with

Fat Spaniel ®

OPP Logger Software

INTERNAL POWER SUPPLY

AURORA or Modbus devices

Modbus or 3 rd party devices

RS485_1

RS485_2

ETHERNET_2

18 – 36 Vdc Supply Bus + 5V / 0.5A

REVENUE GRADE METER

ETHERNET_1 TCP/IP or Modbus TCP

CT

Reserved

BLOCK DIAGRAM OF AURORA UNIVERSAL

Page 113: Renewable Energy Solutios

113AURORA VISION

PARAMETER AURORA UNIVERSALREVENUE GRADE

AURORA UNIVERSALINDUSTRIAL

AURORA UNIVERSALRESIDENTIAL

PORTFOLIO DASHBOARD Computing Environment High performance platform and Fat Spaniel Open Premise Platform® softwareInteroperability Multi-Vendor Interoperability with popular renewable energy vendors and product modelsData Sampling Rate High Frequency Data Sampling – 1 minute average – that can be varied to meet application requirements

Real-Time Management Compatible with Aurora Vision and Fat Spaniel Prime Software-as-a-Service solutions for real-time performance management and reporting

Upgradability Field Upgradable over the InternetCOMMUNICATIONSSerial Port 1 RS485 interface for Power-One Aurora (or Modbus) devicesSerial Port 2 RS485 interface for 3rd party devices (Modbus or proprietary)

Maximum Devices Per Serial Port 15 per RS485 (recommended)

Ethernet 1 10/100 BaseT Ethernet for WAN and LAN communicationsEthernet 2 ReservedPROTOCOLSPlant Network Transport Protocols Modbus/RTU, Modbus/TCP, SunSpec and vendor-specific

Support LAN/WAN Protocols TCP/IP, HTTP, DHCP, SSLREVENUE GRADE SUPPORT

Revenue Grade Meters Integrated revenue grade meter (meets ANSI C.12 for 98%+ accuracy) Not applicable Not applicable

CT Integration Optional 5A CTs allowing for a wide range of current sizes (ordered separately) Not applicable Not applicable

POWER SUPPLYDC Power Supply Input 90...575 VAC, 50/60 HzENVIRONMENTAL PARAMETERSAmbient Temperature Range -20...+55°C / -4...+131°F -20...+55°C / -4...+131°F -10...+40°C / 14...+104°FEnvironmental Protection Rating NEMA 4X NEMA 4X Indoor only

Relative Humidity <90% Non-Condensing <90% Non-Condensing Not applicableENVIRONMENTAL PARAMETERS

Dimension 393.4mm x 352.0mm x 161.0mm /15.2” x 13.9” x 6.3”

393.4mm x 352.0mm x 161.0mm /15.2” x 13.9” x 6.3”

77.0mm x 111.0mm x 26.0 mm3.03” x 4.4” x 1.0”

Weight < 3.6 kg / 7.9 lb < 3.6 kg / 7.9 lb < 0.2 kg / 0,4 lb

Page 114: Renewable Energy Solutios

PVI-STRINGCOMBPVI-STRINGCOMB-US

GENERAL SPECIFICATIONSCENTRALIZED MODELS

PVI-STRINGCOMBPVI-STRINGCOMB-US

114 AURORA VISION

Page 115: Renewable Energy Solutios

FeaturesFeatures

Up to 20 strings directly connectableCartridge fuse on each input for over current protection10 Hall-eff ect current sensors for fast and precise monitoring and fault diagnosticIntegrated DC disconnection switch (-US and -S version)Rugged watertight powder-coated aluminum enclosureRS485 serial bus for communication with the central inverter4 analog inputs for ambient sensors: temperature, irradiance, wind speed, anti-theftAvailable fuse size: 10A, 12A, 16A, 20AInternal auxiliary power supply and additional output for external auxiliary (-S Version)Overvoltage protection on DC power line and signals via replaceable varistors (-S Version)

••••••••••

The Aurora PVI-STRINGCOMB string combiner box is an ideal complement to the Aurora commercial and utility grade inverter that ensures the same monitoring accuracy of the PV generator typically achieved with string inverters.

Up to 10 channels of individual or paired string currents can be accurately monitored via hall eff ect sensors, and any issue detected promptly signaled to the managing inverter and the system supervisor to allow prompt detection of the faulty strings.

All string combiner boxes include surge protection with removable elements as well as fuse protection for each couple of string channels. It is available with a fully-integrated DC switch (optional on -S version), fuse and remote controlled DC disconnect function.

Features

115AURORA VISION

VISI

ON

Page 116: Renewable Energy Solutios

Block Diagram

116 AURORA VISION

BLOCK DIAGRAM OF STRINGCOMB

INPU

T ST

RIN

G C

ON

NEC

TORS

EXTERNALSERVICES CONTROL UNIT

- RS485

+ RS485

SURGE VOLTAGEPROTECTIONRS485 LINE

V

TOTALPV VOLTAGE

MONITOR

FUSE STATUS CURRENT SENSE

+

+

FUSE STATUS CURRENT SENSE

DCBREAKER

S1(+)

S2 (+)

S19 (+)

S20 (+)

S1(-)

S2 (-)

S20 (-)

S19 (-)

S3(+)

S4 (+)

S1(+)

S2 (+)

S3(-)

S4 (-)

-S VERSION

SURGE VOLTAGEPROTECTION ON DC POWER LINE

IRRADIANCEAMBIENT

TEMPERATURE

ANTI-THEFTALARM

SENSORS

ANTI-THEFT

WINDREFERENCE

TEMPERATURE

Page 117: Renewable Energy Solutios

117AURORA VISION

PARAMETER AURORA® STRINGCOMB AURORA® STRINGCOMB-S

Input SideDC Input String Voltage Range 250 ÷ 850 V 250 ÷ 850 VAbsolute Maximum DC Input String Voltage 1000 V 1000 VMaximum DC Current for Each Measurement Channel 20.0 A 20.0 AMeasument Channels 10 10Strings for Each Measurement Channel 2 2Maximum Number of Input Strings 20 20Number of Input String for Each Fuse 2 2String Cable Cross Section 6 mm2 max. 6 mm2 max.Output SideMaximum Output Current 160.0 A 125.0 AOutput Cable Connection 1 x M10 (200 mm2 max.) 1 x M10 (200 mm2 max.)Ground Connection Cable 1 x M8 (350 mm2 max.) 1 x M8 (350 mm2 max.)Output DC Switch Rating Not available 125 A / 1,000 VCommunicationUser Interface 1 x RS485 1 x RS485FeaturesAnti-theft Alarm (opt.) Yes YesAnemoter Sensor Monitoring (opt.) Yes YesTemperature Sensor Monitoring (opt.) Yes YesReference PV Cell Monitoring (opt.) Yes YesData MonitoringString Currents Yes YesString Fuse Status Yes YesAmbient Parameters Yes YesOvervoltage status Yes YesEnvironmetal ParametersAmbient Temperature Range -25...+55°C / -13...131°F -25...+55°C / -13...131°FRelative Humidity 0...100 % condensing 0...100 % condensingMaximum Operating Altitude without Derating 1000m / 3280 ft 1000m / 3280 ftEnvironmental Protection Rating IP 65 IP 65Cooling Natural NaturalEnclosure Aluminun Powder-Coated Aluminun Powder-CoatedDimension (H x W x D) 559mm x 757mm x 250mm / 22.0” x 29.8” x 9.8” 559mm x 757mm x 250mm / 22.0” x 29.8” x 9.8”Weight < 23 kg / 50.7 lb < 25 kg / 55.1 lbWarranty 5year standard 10/15/20 optional 5year standard 10/15/20 optionalSafetyMarking CE CESafety and EMC Standard EN 50178, EN 61000-6-2, EN 61000-6-4 EN 50178, EN 61000-6-2, EN 61000-6-4Available Products Variants10 A x 20 input strings or 20 A x 10 input strings PVI-STRINGCOMB Not available

10 A x 20 input strings or 20 A x 10 input strings with DC switch Not available PVI-STRINGCOMB-S

Page 118: Renewable Energy Solutios

Block Diagram

118 AURORA VISION

BLOCK DIAGRAM OF STRINGCOMB FOR NORTH AMERICA

PV FIELD

REFERENCETEMPERATUR

AMBIENTTEMPERATURE

ANTI-THEFTALARM

SENSORS

M/S°C

W/SM

CONTROL UNIT

INPU

T ST

RIN

G C

ON

NEC

TORS

FUSE STATUS CURRENT SENSE

EXTERNALSERVICES

UNGROUNDEDCONDUCTOR

GROUNDEDCONDUCTOR

- RS485

+ RS485SURGE VOLTAGE

PROTECTIONRS485 LINE

DC BREAKERTOTALPV VOLTAGE

MONITOR

DC BREAKER STATUS

ANTI-THEFT

V

WIND

S1(+)

S2 (+)

S19 (+)

S20 (+)

S1(-)

S2 (-)

S20 (-)

S19 (-)

Page 119: Renewable Energy Solutios

119AURORA VISION

PARAMETER AURORA® STRINGCOMB-US

Input SideDC Input String Voltage Range 250 ÷ 600 VAbsolute Maximum DC Input String Voltage 600 VMaximum DC Current for Each Measurement Channel 20.0 AMeasument Channels 10Strings for Each Measurement Channel 2Maximum Number of Input Strings 20Number of Input String for Each Fuse 1String Cable Cross Section AWG 20 ÷ 6Output SideMaximum Output Current 200 AOutput Cable Connection 2 x 300 kcmil (Each Pole)Ground Connection Cable 2 x 300 kcmilOutput DC Switch Rating 200 A / 600 VCommunicationUser Interface 1 x RS485FeaturesAnti-theft Alarm (opt.) YesAnemoter Sensor Monitoring (opt.) YesTemperature Sensor Monitoring (opt.) YesReference PV Cell Monitoring (opt.) YesData MonitoringString Currents YesString Fuse Status YesAmbient Parameters YesOvervoltage status YesEnvironmetal ParametersAmbient Temperature Range -25...+55°C / -13...131°FRelative Humidity 0...100 % condensingMaximum Operating Altitude without Derating 1000m / 3280 ftEnvironmental Protection Rating NEMA 4XCooling NaturalEnclosure Aluminun Powder-CoatedDimension (H x W x D) 800mm x 655mm x 246mm / 31.5” x 25.8” x 9.7”Weight < 30.4 kg / 67 lbWarranty 5year standard 10/15/20 optionalSafetyMarking cCSAusSafety and EMC Standard UL 1741, CSA-C22.2 No. 107.1-01Available Products Variants10 A x 20 input strings or 20 A x 10 input strings PVI-STRINGCOMB-US

Page 120: Renewable Energy Solutios

AURORA ENVIRONMENTAL

GENERAL SPECIFICATIONS

The Aurora Environmental Meteorological Measurement System consists of a Meteorological Module (MM) and a Power Distribution and Communications Module (PDCM).

The Aurora Environmental system automatically monitors site meteorological conditions and photovoltaic panel temperature in real-time, transmitting sensor measurements to the FST data center for site status monitoring and management.

The Aurora Environmental is delivered ready for installation and use; only requiring the installer to mechanically mount the modules on a user supplied mast, connect AC power to the PDCM, and initialize an automatic system configuration process. No special tools, software, or on-site calibration is required.

120 AURORA VISION

NEW

GENERAL SPECIFICATIONS GENERAL SPECIFICATIONS

METEOROLOGICAL MODULE (MM)

Features

Page 121: Renewable Energy Solutios

121AURORA VISION

PARAMETER METEOROLOGICAL MODULE (MM)

SensorsWind Speed Range: 1.75-212mph, Starting threshold 1.75mphWind Direction Range 0...360 degrees, Resolution 1 degreeRainfall Resolution: 1mm per tipRelative Humidity Accuracy: +/- 5% 90...100%, +/- 3% 10...90%Solar Radiation Spectral range 300...1100nm, accuracy +/- 2.5%, range 0...2000 W/m2

Air Temperature Range -40...+50°C, accuracy +/- 0.6°CPV Panel Temperature Range -40...+125°C, accuracy +/- 0.6°CDimensions(Maximums including sensors and mounting bracket)Dimension (H/L/W) 459.0mmm x 559.0mm x 310.0mm / 18.1” x 22.0” x 12.2”Packaged 559.0mm x 559.0mm x 381.0mm / 22.0” x 22.0” x 15.0”Weight 2.31 kg / 5.0 lbPackaged 5.44 kg / 12.0 lb

PARAMETER POWER DISTRIBUTION AND COMMUNICATIONS MODULE (PDCM)

GeneralInternal Module Certifications CE & FCCOperating Temperature -20...+70°C / -4...+158°FRelative Humidity 0...90% non-condensingInputs & OutputsInput Power 100...240 VAC 50/60 Hz @ 2A (max) (user supplied cable)

Output Power (to MM) 22 VDC @ 50 ma (nominal) (P/N 25754, supplied)Data Input Ethernet connextion to external Ethernet switch (user supplied)Data Output Serial RS232 cable to the MM (P/N 25755, supplied)Packaged < 5.44 kg / 12.0 lbDimensionsL/W/H 292.1mm x 342.9mm x 139.7mm / 11.5” x 13.5” x 5.5”Packaged 508.0mm x 406.4mm x 304.8mm / 20.0” x 16.5” x 12.0”Weight < 4.08 kg / 9 lbPackaged < 6.8 kg / 15 lb

POWER DISTRIBUTION AND COMMUNICATIONS MODULE (PDCM)

Page 122: Renewable Energy Solutios

PVI-AEC-EVO

GENERAL SPECIFICATIONSEASY CONTROLPVI-AEC-EVO

Features

The Easy Control data logger links Power-One inverters and balance-of-system components over the Internet to performance monitoring and management systems such as Aurora Vision and Fat Spaniel Prime Edition.

Connects up to 128 Power-One devices using RS485 communications for low-frequency data sampling.

Collects performance information such as energy harvest, power, voltage and inverter status.

122 AURORA VISION

Page 123: Renewable Energy Solutios

Block Diagram

123AURORA VISION

PARAMETER PVI-AEC-EVOCommunicationInverter Communication (Port 1) 1 x RS485 Additional Inverter Communication (Port 2) 1 x RS485 Configurable as Interface to Aurora

Maximum Number of AURORA Devices (1) 64xstringinverters or 32x55kW conversion module (central inverter) for Each RS485PC Communication Ethernet 10/100MbpsFeaturesConfigurable Analog Inputs 2 configurable as 0 to 10 Vdc or 4 to 20 mA Temperature Analog Input 1 x PT100 or PT1000 Sensor with Autosetting

Configurable Digital Inputs 4 x Opto Isolated as Status Inputs (for Alarms) or Power Management (PM) Control Signals 2 x Opto Isolated as Status Inputs or Pulse Converter Inputs (from Energy Meter)

Digital Outputs 3 x Relais Power Contacts 230 V / 3 ADigital Outputs Configurable 2 x Opto Isolated (27 V, 50 mA) Output Status or Pulse OutputPower Supply

AC/DC Power Supply Input: 100...240 VAC, 50/60 Hz - Output: 24 VDC, 0.75 A18...48 VDC, 1 A

Maximun Consumption < 7,5 WBattery for Integrated Clock Lithium Type Li2032Environmental ParametersAmbient Temperature Range -20...+55°C (-13...131°F)Environmental Protection Rating IP20Relative Humidity < 90% Non CondensingMechanical Dimensions H x W x D 190mm x 90mm x 63mm / 3.54” x 6.30” x 2.48” - 9 ModulesWeight < 0.36 kg / 0.80 lbMounting System 35 mm Top Hat DIN Rail (EN50022)Available Product VariantsStandard PVI-AEC-EVOAccessories (Ordering Code)Power Supply YesIrradiance Sensor 0 - 10V (PVI-AEC-IRR) OptionalIrradiance & Module Temp. Sensor 0 - 10V (PVI-AEC-IRR-T) OptionalPT-100 Self-Adhesive Sensor (PVI-AEC-T100-ADH) OptionalPT-100 Signal Converter, 24 V supply (PVI-AEC-T100-24V) OptionalPT-1000 Sensor in case with Integrated Converter (PVI-AEC-T1000-INTEGR) OptionalWind Speed Sensor - Anemometer (PVI-AEC-WIND) OptionalSD Card (1GB) YesSafetyMarking CESafet and EMC standard PVI-AEC-EVO: EN 60950, EN 55022, EN 55024(1) AURORA Devices are AURORA String Inverters and Modules for CENTRAL AURORA Inverter. Monitoring of String Comb is done via Strincomb Manager Module configured in Central Inverter; the maximum number of STRING COMB for each Stringcomb Manager is 12.

SUPPLY BUS+ 5 V / 0.5AINTERNAL

POWER SUPPLY

DISPLAY

CPU

KEYBOARD

AURORADEVICES

USB_MINI

USB_TYPE A

ETHERNET 10/100

SD / MMC CARD

CONFIGURABLEANALOG INPUT

PT 100 / PT 1000SENSOR

6

OUTPUT STATUS (DO_PWM1)

OUTPUT STATUS (DO_PWM2)

18 - 36 Vdc

RS232

TX

RX

RTN

3

RELAYOUTPUT

OPTOISOLATED 250V / 3A

2

RELAY 1

RELAY 2

RELAY 3

RS485_1

+ T/R- T/RRTN

RS485_2

+ T/R- T/RRTN

+-R

AURORA DEVICES/ MOD BUS

A / D

CONFIGURABLEDIGITAL INPUT

3

Page 124: Renewable Energy Solutios

PVI-DESKTOP

GENERAL SPECIFICATIONSDESKTOP MODELS

PVI-DESKTOP

Features

Power-One’s PVI-Desktop provides the ability to monitor performance of connected inverters and is ideal for residential and small commercial PV and wind applications.

In addition to wired connectivity (via RS-485), the PVI-Desktop system can also be connected to six targets inverters via a wireless RF tranceiver link capable of connectivity anywhere within 960 feet (free field). The wireless communication requires an optional radio tranceiver module to be installed in each inverter.

The system can be linked to a personal computer via Bluetooth (-BT version) or USB connectivity, and will therefore allow performance monitoring at any location with online access using Aurora Communicator. Energy harvesting data for up to six Aurora inverters can be monitored simultaneously using the PVI-Desktop.

124 AURORA VISION

Page 125: Renewable Energy Solutios

Desktop Highlights

Personal ComputerAURORADesktop

RS485

RS485 RS485915MHz

915MHz 915MHz

915MHz

USB 2.0

125AURORA VISION

PARAMETER PVI-DESKTOP PVI-DESKTOP-AU PVI-DESKTOP-USInverter Communication - RadioRadio Communication 864 MHz 915...927 MHz 915 MHzMaximum Radio Coverage 300 m / 960 ft Free SpaceWired Communication RS485 (Half Duplex 19200 bps)Maximum Wired Conenction 2000 m / 3280 ftPC CommunicationWireless Bluetooth (Optional)Wired Communication USB 2.0Connectivity

Compatibility with Inverters AURORA® PVI String Series(1)

Maximum Number of AURORA Inverters 6FeaturesData Displaying Parameters All Parameters of AURORA Inverters(1)

Data Storage Parameters Power and Energy (by SD Card)Software Upgrade USB (AURORA COMMUNICATOR) or SD CardLanguage IT / EN / ES / DE / FRPower SupplyAC/DC Adapter 5 V, 1 A, 50/60 HzUSB YesStand Alone Rechargeble Li-Ion BatteryDisplayDimensions 3.5”Color YesResolution QVGA 320X240 pxType Integrated Touch Screen ResistiveEquipment Stylus Pen YesAC Adapter YesUSB Cable YesSD Card (1GB) YesEnvironmental ParametersAmbient Temperature Range in °C (°F) 0/+ 40°C (32/104°F)Environmental Protection Rating IP20 IP20 NEMA 1Relative Humidity < 90% Non CondensingMechanical Dimensions H x W x D 102mm x 125mm x 35mm / 4” x 5” x 2.1”Weight < 0.4 kg / 0.88 lbMounting Kit (Desk and Wall) YesAvailable Product VariantsStandard PVI-DESKTOP PVI-DESKTOP-AU PVI-DESKTOP-USBluetooth PVI-DESKTOP-BT PVI-DESKTOP-BT-AU PVI-DESKTOP-BT-USSafetyMarking CE C-Tick FCC

Safety and EMC Standards EN 60950, EN 62311, EN 301 489, EN 50371, EN 300 220, EN 300 328 AS/NZS 4268 FCC Cfr 47 part 15

(1) All AURORA String Series equipped with Radio Transmitter (Optional Feature). Further information about compatibility on the AURORA PVI-DESKTOP FAQ – Frequently Asked Question

Page 126: Renewable Energy Solutios

126 AURORA VISION126 AURORA VISION

AURORA INSTALLEREASY SOFTWARE INTERFACE TOOL FOR WIND TURBINE/INVERTERINTEGRATION FOR SPECIALISTS

This free software works on Windows XP as well as Windows 7 and represents the basic tool for the optimization of the power curve that will reside onto the inverter itself.It will be conveniently used by professionals and OEM’s during inverter/turbine characterization, energy production evaluation as well as stability verifier.

FEATURESPower Curve UploadingAdjusting basic function parametersError and Warning Logs downloadLog data every second for development and optimization phasesReal time values monitoring, (Vin, Iin, Pin, Freq.in, Vout, Iout, Pout, Freq.out, Status, Temperatures, Energy, Leakage Current, Isolation Resistance) Total Energy Harvest info reading (daily, weekly, monthly, yearly, period, lifetime)Log of the settings changesProduces text data files that can be converter and elaborated with Excel

Drivers for connection to a PC via Aurora Inverter’s RS485 or USB ports are available when using Power-One RS485/USB converter.

••••••••

Dynamically to be improved

Dynamically stable

0

500

1000

1500

2000

2500

3000

3500

4000

0 100 200 300 400 500

Pac

out

Vdc in

e�ective power curve loaded

Pac, data collection example

0

500

1000

1500

2000

2500

3000

3500

4000

0 100 200 300 400 500

Pac

out

Vdc in

e�ective power curve loaded

Pac, data collection example

0

500

1000

1500

2000

2500

3000

3500

4000

0 100 200 300 400 500

Pac

out

Vdc in

e�ective power curve loaded

Pac, data collection example

0

500

1000

1500

2000

2500

3000

3500

4000

0 100 200 300 400 500

Pac

out

Vdc in

e�ective power curve loaded

Pac, data collection example

Page 127: Renewable Energy Solutios

127AURORA VISION 127AURORA VISION

AURORA INSTALLER

Download the free software from Power-One official web site:http://www.power-one.com/renewable-energy/file-downloads

Latest releases will be published in the same web page.English language only but intuitive menu will drive user in choices.

It works whenever connected to a powered up inverter.

Page 128: Renewable Energy Solutios

128 AURORA WIND

Page 129: Renewable Energy Solutios

WIN

DW

IND

WIND

129AURORA WIND

Page 130: Renewable Energy Solutios

Power-One Large Wind Converter Solutions

Vision

Following the growing demand of wind power and the market trend of introducing higher power turbine ratings with high grid management requirements, the Power Converter Unit is a key component of the turbine. The needs of OEMs to reduce the installation cost per kWh and the actual trend of developing high specialized components manufactured to specification brought Power-One to enter this market with our own model. We off er a wide range of cost eff ective and fl exible solutions for large and small scale wind turbines with high performances in terms of reliability, efficiency, grid support capabilities and power output quality. Multilevel Technology

All Power-One three-phase inverters adopt IGBT-based multi-level topologies. Power-One Aurora wind converters are based on a Neutral Clamp 3-level topology for both medium voltage and low voltage applications. Multilevel topologies allow to achieve top perfor-mances in terms of conversion efficiency, carrier frequency and generator dV/dt. Reliability and cost competitiveness is achieved using industry standard rated IGBTs. The AC quality is compliant with the latest edition of standard for total harmonic current and voltage distortion limits. Power-One adopts state of the art vector control algorithm in order to regulate active and reactive power fed to the grid with the production of reactive energy used to compensate the capacitive and inductive load of the grid.

Flexibility and Modularity

Power-One inverters are designed to work in parallel architecture in order to reach the maximum wind turbine power output up to 10MW and above. Power-One inverter mo-dules are introducing a new concept of fl exibility in this Power Converter environment industry and can be matched and completed with a passive or active rectification stage depending by the wind turbine OEMs needs in case of full conversion and/or doubly fed applications.

130 AURORA WIND

Page 131: Renewable Energy Solutios

Power-One Converter Solutions for Full Conversion

Large Wind and Hydro turbines working at variable speeds, geared or direct driven, need a full converter solution.

The system’s general structure can be modelled with a rectification stage interfacing the generator and an inverter stage facing the grid.

Power-One is able to provide fl exible solutions in terms of technology whether there is a need of an active front end facing the generator especially in case of direct drive or hybrid turbines or a passive rectification with 6 or 12 pulses operation mode.

Power-One Converter Solutions for Doubly Fed generators

DFiG architecture is still the most popular in the market because of its ability to work efficiently in a range of variable speed conditions

Power-One is introducing multi-level back to back converters for this application and so able to improve dramatically the performances in terms of efficiency and consequently energy harvesting.

Power-One converters for DFiG applications off ers a much higher power density giving the possibility of installing the converter in the nacelle.

- 690V Multi-level topology IGBT’s based- Liquid cooling - Modular solution- Electrolytic capacitors free- IGBT based Active Crowbar - Power factor management- State of the Art Control Algorithms- Fiber Optics

- Medium Voltage or 690V solutions- Liquid cooling - Modular solution- Electrolytic capacitors free- Multi-level topology IGBT’s based

- IGBT based chopper - Wide range power factor management- State of the Art Control Algorithms- Fiber Optics

PowerGrid

G3 ~

Stator

RotorControl

PowerGrid

PowerGrid

G3 ~

Active Front End

Inverter

PowerGrid

G3 ~

Diode Bridge Front End

Inverter

Grid

Converter Features

Converter Features

131AURORA WIND

Page 132: Renewable Energy Solutios

LSWI-2.5MW

GENERAL SPECIFICATIONS

LSWI-2.5MW

132 AURORA WIND

Page 133: Renewable Energy Solutios

133AURORA WIND

Following the growing demand for wind power and the market trend to introduce higher power turbines using ‘In Line Technology’, the Power Converter Unit will be a real ‘core’ component of the turbine permanent magnet generator system in the following years. OEM’s need to reduce the installation cost per kWh and the trend of developing high specialized components manufactured to specification brought Power-One to introduce the new ‘Large Wind 2.5MW inverter module’.

Power-One’s inverter module has been developed to meet the highest technology needs where the turbine interface the grid, having an innovative IGBT’s based design that incorporates Power-One’s Industry Leading Technology for Renewable Energy Inverters.

Key features include liquid cooling and Medium Voltage operation, in addition to an outstanding 98.7% conversion Efficiency result, are ideal for multi-MW Wind Power Generators off -shore and on-shore applications.

Medium voltage of 5500 VDC lowers cabling costsLiquid coolingIndustry-leading power density and higher reliabilityHigh conversion efficiency (98.7% at full load)Modular design permits fl exibility in sizing multiple invertersLow output voltage harmonic distortion; allows higher power quality to the utility gridPower conversion state of the art technology3-Level NPC topologyIGBT TechnologyVector control algorithm with active and reactive power regulation

••••••••••

FeaturesW

IND

Page 134: Renewable Energy Solutios

Block Diagram

134 AURORA WIND

MEDIUM VOLTAGE With larger turbine unit sizes, medium-voltage converter systems are most suitable for the corresponding high power.

Power-One inverter module is designed to answer this requirement and will help OEM’s to reduce the size of the turbines and reduce the cost of the system itself.

FLEXIBILITY AND MODULARITYThe Power-One inverter is designed to work in parallel for larger Wind Turbines of 10MW and potentially above.

Power-One’s inverter module is introducing a new concept of flexibili-ty in this Power Converter environment industry and can be matched and completed with a passive or active rectification stage depending on the wind turbine OEM’s needs.

LIQUID COOL FOR OFFSHORE AND ONSHORE APPLICATIONThe Power-One inverter module is specifically designed to meet the requirements coming from offshore and onshore applications and is equipped with an original designed Liquid Cooled system.

The extremely-integrated design of the inverter’s (2mx2m) cabinet works very effectively in a marine environment by providing protection from water, oil, and gas. One of the most important benefits for a power converter located in a difficult offshore area is to ensure reliability while allowing for quick and easy maintenance. Power-One’s modularity design concept has been implemented in order to fulfill this critical task.

PMSG

DSP CONTROLLERVoltageSensor

Trasformer

HighVoltage

Line

Converter Front End

+ -

+ -

+ -

C1

C2

D5

D6

D3

D4

D1

D2

Z1

Z2

Z3

Z4

Z5

Z6

Z7

Z8

Z9

Z10

Z11

Z12

VoltageSensor

L1

L2

L3

C5 C6 C7

Page 135: Renewable Energy Solutios

135AURORA WIND

PARAMETER LSWI-2.5MW

Input

Nominal Input Range 3300...4300 V

Max Transient DC Voltage 4300...5300 V

Output

Continuous rated power @ 50°C 2.575 MW

AC Max Current rating 725.0 A

Nominal AC Output Voltage 2400 V

AC Frequency Tolerance 50Hz / 60Hz ± 3Hz

Nominal Power Factor (Cosphiac,r) > 0.995 (adj. ± 0.8)

AC Current Harmonics (THD%) <3% with grid voltage (<2% Full Load)

Conversion Efficiency

Peak Efficiency % (@ P nom) 98.7%

Environmental

Environmental Protection Degree IP43

Operating Temperature Range -30°C...+50°C

General Data

Local Communication RS485 – CANBUS

Low Voltage Ride Through Compliance with US & EU requirements

Cooling Liquid Cooled. Required external Water pump and heat exchanger

Weight 3500kg / 7716lb

Dimension (H x W x D) 2100mm x 2522mm x 803mmx / 82.7” x 99.3” x 31.6”

Safety

Marking CE

Page 136: Renewable Energy Solutios

136 AURORA WIND

MSWI-55.0MSWI-110.0

GENERAL SPECIFICATIONS

MSWI-55.0MSWI-110.0

NEW

Page 137: Renewable Energy Solutios

137AURORA WIND

Reduced susceptibility to a single fault. In case of a component failure, a maximum of 55kW will be lostReduced acoustic noise due to the high switching frequencyReverse-polarity protection minimizes potential damage caused by array mis-wiringMaximum input voltage up to 1000 VdcIntegrated DC and AC distribution and protection. Fully equipped for connection, additional accessories not requiredEasy installation and maintenance procedure. Front extractible DC/AC converters and front accessibility to all critical parts High efficiencies deliver more energyIndependent RS-485 communication interface for inverter power curve driving

•••••

••

These Aurora Medium Scale Wind Inverters are designed for community scale wind system. These scalable modular inverter system, based on 55kW conversion modules, increases usable power and improve availability.

As per modular concept, in case of single module failure, the system is able to continue harvesting energy with a self exclusion of the faulty cluster.

Industry-leading power conversion efficiencies of up to 96.3% optimize energy harvesting across a wide array of operating conditions. Inverter systems are delivered pre-configured and pre-tested in rugged enclosures.

FeaturesW

IND

Page 138: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

138 AURORA WIND

BLOCK DIAGRAM OF MSWI-110.0 WITH TRANSFORMER

MSWI-55.0 MSWI-110.0

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

% of Rated Output Power

Effi

cien

cy, %

330 Vdc

370 Vdc

480 Vdc

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

% of Rated Output Power

Effi

cien

cy, %

330 Vdc

370 Vdc

480 Vdc

IN1 (+)

IN 1 (-)

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

INVERTER MODULE 55kW

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

INVERTER MODULE 55kW

ACCONTACTOR

AC MAGNETICBREAKER

EXTERNAL GRID INTERFACE-

NIGHT CONTROL

400 Vac50 Hz, 3 Ph

100kVATRANSFORMER

PE

PE

PE

L1

L2

L3

IN 2 (+)

IN 2 (-)

Page 139: Renewable Energy Solutios

139AURORA WIND

PARAMETER MSWI-55.0 MSWI-110.0

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 1000 V 1000 VInput DC Voltage Range (VDCmin,r ... VDCmax,r) 475...950 V 475...950 VInput DC Range (VDCmin,f ... VDCmax,f) at Full Power 475...850 V 475...850 VNumber of Independent Modules Master/Slave 1 2Maximum Combined DC Input Current (Idcmaxc) 124 A 248 AMaximum DC Input Current for Each Module (Idcmax,m) 124 A 124 A Number of DC Inputs Pairs 1 2DC Connection Type Cable lugInput ProtectionReverse Polarity Protection NoInput Over Voltage Protection - Varistor 2 for each input pair, Class IIGenerator Isolation Control According to local standardOutput SideAC Grid Connection Type Three phase (Δ / Υ)Rated AC Power (Pac,r) 55 kW 110 kWRated Grid Voltage (Vac,r) 400 VAC Voltage Range (Vacmin...Vacmax) 320...480 V (1)

Maximum Output Current (Iac,max) 81 A 160 ARated Frequency (fr) 50 / 60 HzFrequency Range (fmin...fmax) 47...53 / 57...63 Hz (2)

Power Factor (Cosphiac,r) > 0.995Total Harmonic Distortion < 3% (@Pac,r)AC Connection Type 1 x 95 mm2 (M8)Output ProtectionAnti-Islanding Protection According to local standardOutput Overvoltage Protection (Varistor) Yes, Class IIOperating PerformanceMaximum Efficiency (ηmax) 93.30% 96.4%Weithted Efficiency (ηEURO / ηCEC ) 95.1% / 96.0% 95.2% / 96.0%Stand-by Consumption < 17 W < 24 WAC Auxiliary Supply 3x400 Vac +N, 50/60 HzAuxiliary Supply Consumption < 0.36% of Pac,r < 0.31% of Pac,r

Inverter Switching Frequency 18 kHzCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)User Interface 16 characters x 2 lines LCD display for each moduleEnvironmentalAmbient Temperature Range -10...+ 60°C/+14...140°F con derating sopra 50°C/122°FRelative Humidity 0...95% non condensingNoise Emission < 62 dB(A) @ 1m < 65 dB(A) @ 1mMaximum Operating Altitude without Derating 1000 m / 3280 ftPhysical Environmental Protection Rating IP 20Cooling Air ForcedRequired Air Cooling Flow 1600 m3/h - 944 CFM 2800 m3/h - 1652 CFMDimension (H x W x D) 1675mm x 1250mm x 850mm / 65.9” x 49.2” x 33.5”Weight <700 kg / 1543 lb <800 kg / 1765 lbWeight of the module <60 kg / 132 lbSafetyTransformer YesMarking CESafety and EMC Standard EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12Grid Standard Guideline ENEL, G59

1. The AC voltage range may vary depending on specific country grid standard2. The Frequency range may vary depending on specific country grid standard

Page 140: Renewable Energy Solutios

MSWI-50-USMSWI-100-US

GENERAL SPECIFICATIONS

MSWI-50-US-208MSWI-50-US-480MSWI-100-US-208MSWI-100-US-480

140 AURORA WIND

Page 141: Renewable Energy Solutios

141AURORA WIND

Reduced susceptibility to a single fault. In case of a component failure, a maximum of 50kW will be lostReduced acoustic noise due to the high switching frequencyReverse-polarity protection minimizes potential damage caused by array mis-wiringMaximum input voltage up to 600 VdcIntegrated DC and AC distribution and protection. Fully equipped for connection, additional accessories not requiredEasy installation and maintenance procedure. Front extractible DC/AC converters and front accessibility to all critical parts High efficiencies deliver more energyIndependent RS-485 communication interface for inverter power curve driving

•••••

••

These Aurora Medium Scale Wind Inverters are designed for community scale wind system. These scalable modular inverter system, based on 50kW conversion modules, increases usable power and improve availability.

As per modular concept, in case of single module failure, the system is able to continue har-vesting energy with a self exclusion of the faulty cluster.

Industry-leading power conversion efficiencies of up to 95.8% optimize energy harvesting across a wide array of operating conditions. Inverter systems are delivered pre-configured and pre-tested in rugged enclosures.

FeaturesW

IND

Page 142: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

142 AURORA WIND

MSWI-50-US MSWI-100-US

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

% of Rated Output Power

Effi

cien

cy, %

330 Vdc

370 Vdc

480 Vdc

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

% of Rated Output Power

Effi

cien

cy, %

330 Vdc

370 Vdc

480 Vdc

BLOCK DIAGRAM OF MSWI-100 WITH TRANSFORMER FOR NORTH AMERICA

IN1 (+)

IN 1 (-)

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

INVERTER MODULE 50kW

REVERSE POLARITYPROTECTION

DCFUSE

DCBREAKER

OVR

EMCFILTER

DC / ACINVERTER

LINEFILTER

CONTACT

CONTROL CIRCUIT

ACFUSE

EMIFILTER

INVERTER MODULE 50kW

ACCONTACTOR

AC MAGNETICBREAKER

EXTERNAL GRID INTERFACE-

NIGHT CONTROL

400 Vac50 Hz, 3 Ph

100kVATRANSFORMER

PE

PE

PE

L1

L2

L3

IN 2 (+)

IN 2 (-)

Page 143: Renewable Energy Solutios

143AURORA WIND

PARAMETER MSWI-50-US-208

MSWI-50-US-480

MSWI-100-US-208

MSWI-100-US-480

Input SideAbsolute Maximum DC Input Voltage (Vmax,abs) 600 V 600 VInput DC Voltage Range (VDCmin,r ... VDCmax,r) 330...600 V 330...600 VInput DC Range (VDCmin,f ... VDCmax,f) at Full Power 330...600 V 330...600 VNumber of Independent Modules Master/Slave 1 1Maximum Combined DC Input Current (Idcmaxc) 170 A 340 AMaximum DC Input Current for Each Module (Idcmax,m) 170 A 170 ANumber of DC Inputs Pairs 1 2DC Connection Type Cable lug M10/M12 Cable lugInput ProtectionReverse Polarity Protection No NoInput Over Voltage Protection - Varistor Yes YesGenerator Isolation Control Yes YesOutput SideAC Grid Connection Type Three phase (Δ) Three phase (Δ)Rated AC Power (Pac,r) 50 kW 100 kWRated Grid Voltage (Vac,r) 208 V 480 V 208 V 480 VAC Voltage Range (Vacmin...Vacmax) 183...228 V 422...528 V 183...228 V 422...528 VMaximum Output Current (Iac,max) 139 A 61 A 278 A 121 ARated Frequency (fr) 60 Hz 60 HzFrequency Range (fmin...fmax) 59.3...60.5 Hz 59.3...60.5 HzPower Factor (Cosphiac,r) > 0.995 > 0.995Total Harmonic Distortion < 4% (@Pac,r) < 4% (@Pac,r)AC Connection Type 3 x 2/0 AWG 90° / M10 3 x 2/0 AWG 90° / M10Output ProtectionAnti-Islanding Protection According to UL 1741/IEE1547 According to UL 1741/IEE1547Output Overvoltage Protection (Varistor) Yes Yes Operating PerformanceMaximum Efficiency (ηmax) 95.6% 95.8% 95.6% 95.8%Weithted Efficiency (ηEURO / ηCEC ) - / 95.0% - / 95.0%Stand-by Consumption < 15 W < 30 WAC Auxiliary Supply 3 x 480 Vac, 50/60 Hz 3 x 480 Vac, 50/60 HzAuxiliary Supply Consumption < 0.40% of Pac,r < 0.40% of Pac,r

Inverter Switching Frequency 18 kHz 18 kHzCommunicationWired Local Monitoring PVI-USB-RS485_232 (opt.) PVI-USB-RS485_232 (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)

User Interface 16 characters x 2 lines LCD display for each module

16 characters x 2 lines LCD display for each module

Environmental

Ambient Temperature Range -10...+ 50°C/+14...122°F with derating above 40°C/104°F

-10...+ 50°C/+14...122°F with derating above 40°C/104°F

Relative Humidity 0...95% non condensing 0...95% non condensingNoise Emission < 62 dB(A) @ 1m < 62 dB(A) @ 1mMaximum Operating Altitude without Derating 1000 m / 3280 ft 1000 m / 3280 ftPhysical Environmental Protection Rating IP 20 / NEMA 1 IP 20 / NEMA 1Cooling Air Forced Air ForcedRequired Air Cooling Flow 1500 m3/h - 885 CFM 2000 m3/h - 1180 CFM

Dimension (H x W x D) 1275mm x 1675mm x 850mm / 50.2” x 66” x 33.5”

1275mm x 1675mm x 850mm / 50.2” x 66” x 33.5”

Weight 700 kg / 1543 lb 850 kg / 1873 lbWeight of the module <70 kg / 154 lb <70 kg / 154 lbSafetyTransformer Yes YesMarking cCSAus cCSAusSafety and EMC Standard UL 1741, CSA - C22.2 N. 107.1-01 UL 1741, CSA - C22.2 N. 107.1-01Grid Standard IEEE 1547 IEEE 1547

Page 144: Renewable Energy Solutios

25kW WIND INTERFACE

GENERAL SPECIFICATIONS

25 kW-WIND-INTERFACE

144 AURORA WIND

NEW

Page 145: Renewable Energy Solutios

This new product added to Power-One’s Aurora wind accessories off ers more fl exibility for small wind applications.

The 25 kW Wind Interface is designed to be a ‘smart’ rectifier which once programmed with the turbine’s power curve it can control the output of single or multiple inverters allowing scalability for installation.

Additionally it provides over-voltage protection and drives both a diversion load and a dumpload braking system.

Conversion efficiency at rating: 99.6%Three-Phase input from PMGUnfused path to breake loadAutomatic diversion load function proportionally introduced on an external dedicated output Adjustable breake and diversion load intervention thresholdsFused wind input to inverterAutomatic brake function above 530 VdcActivation function of external brake resistor Power curve owner Working frequency skip window (optional)

••••••••••

145AURORA WIND

FeaturesW

IND

Page 146: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

146 AURORA WIND

BLOCK DIAGRAM OF 25KW-WIND INTERFACE

1

2

3

GND

BRIDGEDIODE

BRAKINGSWITCH

BR K1 (+)

BR K1 (-)

OUT 1.1(+)

OUT 1.2(+)

OUT 1.3(+)

OUT 1.4(+)

OUT 2.1(-)

OUT 2.2(-)

OUT 2.3(-)

OUT 2.4(-)DIVERSION

LOAD SWITCH

BR K2 (+)

BR K2 (-)

BULK CAPS

GP 1

N.C

N.O

C

GP 2

N.C

N.O

C

GP 3

N.C

N.O

C

RS485INT

+ T

/R

- T/R

GN

D

RS485EXT

+ T

/R

- T/R

GN

D

CAN BUSINT

CA

NL

CA

NH

GN

D

CAN BUSEXT

CA

NL

CA

NH

GN

DEMERGENCY STOP

ES

FC 1

REF

1

FC 2

REF

2

FC 3

REF

3

FC 4

REF

4

CONTROL

PMG

SWITCH(RECOMMENDED)

PARKINGRESISTOR

AUXILIARY BRAKE RESISTOR MAIN BRAKE RESISTOR(RECOMMENDED)

WINDINVERTER

WINDINTERFACE

WINDINVERTER

1

2

3

MAINRELAY

FC 1

BR

K2

(+)

BR

K2

(-)

BR K1 (+)

BR K1 (-)

FREQ CMDGRID

REF 1

IN (+)

IN (-)

FCX (+)/WT (+)

REF (-)/WT (-)

FCX (+)/WT (+)

REF (-)/WT (-)

IN (+)

IN (-)

ES FC 2

REF 2

FC 3

REF 3

FC 4

REF 4

OUT 1.1(+)

OUT 1.2(+)

OUT 1.3(+)

OUT 1.4(+)

OUT 2.1 (-)

OUT 2.2 (-)

OUT 2.3 (-)

OUT 2.4 (-)

L

N

L

N

HFTRANSFORMER

Page 147: Renewable Energy Solutios

147AURORA WIND

PARAMETER 25kW-WIND-INTERFACE 25kW-WIND-INTERFACE-US

Input Side

AC Input Range (No damage) (Vacd,min...Vacd,max) 0...600 V 0...400 V

Operating AC Input Range (Vacmin...Vacmax) 35...600 V 35...400 V

Operating Frequency Range (fmin...fmax) 0...600 Hz (1) 0...600 Hz (1)

Maximum AC Input Current (Idcmax) 85.0 A 85.0 A

Maximum Current in Main Brake Resistor (IMBR,max) 50.0 A 50.0 A

Voltage Range in Main Brake Resistor (VMBRmin...VMBRmax) 0...750 V 0...600 V

Maximum Current in Auxiliary Brake Resistor (IABR,max) 30.0 A 30.0 A

DC Voltage Range in Auxiliary Brake Resistor (VABRmin...VABRmac) 0...1000 V 0...600 V

Type of Inputs Connection Screw terminal block Cable Gland

Screw terminal block Knock Out 3/8”, 3/4”, 1/2”

Input protection

Input Over Voltage Portection - Varistor 4 4

Input Fuse Size 3 x 100.0 A 3 x 100.0 A

Output Side

Maximum Output Power (Pdcmax) 25.0 kW 25.0 kW

Output Voltage Range (Vdc,min...Vdc,max) 50...850 V 50...600 V

Maximum Output Current (Idc,max) 80.0 A 100.0 A

Type of Output Connection Screw terminal block Cable Gland

Screw terminal block Knock Out 3/8”, 3/4”, 1/2”

Output Protection

Output Over Voltage Yes Yes

Operating Performance

Peak Efficiency (ηpeak) 99.6 % 99.6 %

Stand-by Consumption < 6 W < 6 W

Communication

Local Monitoring System RS 485, 1 CAN BUS for parallelling operation RS 485, 1 CAN BUS for parallelling operation

Remote Control AURORA DESKTOP (opt.) AURORA DESKTOP (opt.)

User Interface 16 characters x 2 line LCD display 16 characters x 2 line LCD display

Environmental

Ambient Temperature Range -25...+55°C / -13...131°F -25...+55°C / -13...131°F

Relative Humidity < 100% Condensing < 100% Condensing

Noise Emission < 40 dB(A) < 40 dB(A)

Maximum Operating Altitude without Derating 2000 m / 6560 ft 2000 m / 6560 ft

Physical

Environmental Protection Rating IP 65 NEMA 4X

Cooling Natural Natural

Dimension (H x W x D) 650mm x 350mm x 265mm / 25” x 12.8” x 9” 650mm x 350mm x 265mm / 25” x 12.8” x 9”

Weight 22 kg / 48.5 lb 22 kg / 48.5 lb

Mounting System Wall Bracket Wall Bracket

Safety

Marking CE cCSAus

Safety and EMC standard EN 51178, EN 61000-6-2, EN 61000-6-4 UL 1741, CSA - C22.2 N. 107.1-01

1.The frequency input is for single isolated driving source. When using wind tach, the available frequency range is 5...200Hz. The inverter also provides a +5V internal pull up max. 0.5mA.

Page 148: Renewable Energy Solutios

PVI-12.5-TL-W

GENERAL SPECIFICATIONS

PVI-12.5-TL-OUTD-W

148 AURORA WIND

NEW

Page 149: Renewable Energy Solutios

149AURORA WIND

This Aurora grid-tie wind inverter off ers a unique combination of high efficiencies, installer-friendly designs and long service life. A major selling point of the Aurora Wind inverter is its very wide input voltage range ensuring power is continuously harvested from the lightest breeze to the strongest wind for small wind applications for up to 50kW.

The competitive initial acquisition costs matched with the high efficiencies of up to 97.7% wide input range significantly increase return on investment on wind-power installations.

This compact, weather-sealed inverter has a 16-point profile to best match the power curve of each wind turbine. Wind Interface box is an optional accessory.

‘Electrolyte-free’ power converter to further increase the life expectancy and long term reliabilityTrue Three-Phase bridge topology for DC/AC output converterTransformerless operation for highest efficiencyPower curve customization with high granularity to reach high level of power production yieldOutdoor enclosure for unrestricted use under any environmental conditionsCompact size and high power densityOptimized real time power curve tracking algorithm and improved energy harvestingHigh overload capability: works up the power max limits under most ambient conditionsCompatible with 25kW Wind Interface

•••••••••

FeaturesW

IND

Page 150: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

150 AURORA WIND

PVI-12.5-TL-OUTD-W

360 Vdc580 Vdc750 Vdc

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

360 Vdc

580 Vdc

750 Vdc

BLOCK DIAGRAM OF PVI-12.5-TL-OUTD-W

BOOST 1(DC/DC)

BOOST 2(DC/DC)

BULK CAPSINVERTER(DC/AC)

LINEFILTER

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

GRID PARALLELRELAY

L1

L2

L3

N

PE

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

WIND SPEED INPUTWT (+)

WT (-)

Page 151: Renewable Energy Solutios

151AURORA WIND

PARAMETER PVI-12.5-TL-OUTD-W

Input SideMaximum Absolute DC Input Voltage V(dc,abs) 900 VOperating DC Input Range (Vdcmin...Vdcmax) 100...850 VDC Input range at full power (Vfp,min...Vfp,max) 360...750 V

Dc Power Limitation Power Limit to 10 A max for Vdc≤200 VLinear Derating From MAX to Null [750V≤Vdc≤850V]

Maximum DC Input Current (Idcmax) 36 AMaximum Input Short Circuit Current 44 ADC Connection Type Screw Terminal Block, Cable Glands Input ProtectionReverse Polarity Protection NoInput Over Voltage Protection - Varistor 4Generator Isolation Control YesOutput SideAC Grid Connection Three Phase (Δ/Y)Rated AC Power (Pacr) 12500 WMaximum AC Output Power (Pacmax) 13800 WRated Grid AC Voltage (Vac,r) 400 VAC Voltage Range 320...480 V (1)

Maximum Output AC Current (Iac,max) 20 ARated Frequency (fr) 50 HzFrequency Range (fmin...fmax) 47...53 Hz (2)

Nominal Power Factor (Cosphiac,r) > 0.995Total Harmonic Distortion < 2%AC Connection Type Screw Terminal Block, Cable Glands Output ProtectionAnti-islanding protection According to local standardMaximum AC Overcurrent Protection 22 AOutput Over Voltage Protection - Varistor 3, star connected to common point plus gas arrester to ground Operating PerformanceMaximum Efficiency (ηmax) 97.7%Stand-by Consumption < 10 WCommunicationWired Local Monitoring PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -20...+60°C /-4...140°F with derating above 50°C/122°FNoise Emission < 50 dB(A)Maximum Operating Altitude with Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65 Cooling NaturalDimension (H x W x D) 716mm x 645mm x 222mm / 28.2” x 25.4” x 8.7”Weight 38 kg / 83.8 lbSafetyIsolation Level TransformerlessMarking CESafety and EMC standard EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12Grid Standard Guideline ENEL, VDE 0126-1-1, AS4777, G59/2Available Products VariantsStandard PVI-12.5-TL-OUTD-W

1. The AC voltage range may vary depending on specific country grid standard

2. The Frequency range may vary depending on specific country grid standard

Page 152: Renewable Energy Solutios

SSWI-10.0-I

GENERAL SPECIFICATIONS

SSWI-10.0-I-OUTDSSWI-10.0-I-OUTD-US-208SSWI-10.0-I-OUTD-US-480

152 AURORA WIND

NEW

Page 153: Renewable Energy Solutios

This Aurora grid-tie wind inverter off ers a unique combination of high efficiencies, installer-friendly designs and long service life. A major selling point of the Aurora Wind inverter is its very wide input voltage range ensuring power is continuously harvested from the lightest breeze to the strongest wind. This high-frequency isolated three-phase unit allows for a direct parallel connection of multiple units, allowing for small wind applications for up to 50kW.

The competitive initial acquisition costs matched with the high efficiencies of up to 97.1% wide input range significantly increase return on investment on wind-power installations.

This compact, weather-sealed inverter has a 16-point profile to best match the power curve of each wind turbine. Wind Interface box is an optional accessory.

‘Electrolyte-free’ power converter to further increase the life expectancy and long term reliabilityTrue Three-Phase bridge topology for DC/AC output converterGalvanic isolation by high frequency transformerPower curve customization with high granularity to reach high level of power production yieldOutdoor enclosure for unrestricted use under any environmental conditions Compact size and high power densityOptimized real time power curve tracking algorithm and improved energy harvestingHigh overload capability: works up the power max limits under most ambient conditionsCompatible with 25kW Wind InterfaceEach inverter is set on specifi c grid codes which can be selected in the fi eld

••••••••••

153AURORA WIND

FeaturesW

IND

Page 154: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

154 AURORA WIND

SSWI-10.0-I-OUTD

416 Vdc

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

220 Vdc

362 Vdc

416 Vdc

BLOCK DIAGRAM OF SSWI-10.0-I-OUTD

BOOST 1(DC/DC)

BOOST 2(DC/DC)

BULK CAPSINVERTER(DC/AC)

LINEFILTER

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

GRID PARALLELRELAY

L1

L2

L3

N

PE

HFTRANSFORMER

HFTRANSFORMER

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

WIND SPEED INPUTWT (+)

WT (-)

OPTOISOLATOR

Page 155: Renewable Energy Solutios

155AURORA WIND

PARAMETER SSWI-10.0-I-OUTD-400 SSWI-10.0-I-OUTD-US-208

SSWI-10.0-I-OUTD-US-480

Input SideMaximum Absolute DC Input Voltage V(dc,abs) 520 V 520 VOperating DC Input Range (Vdcmin...Vdcmax) 120...520 V 120...520 V DC Input range at full power (Vfp,min...Vfp,max) 220...470 V 220...470 V

Dc Power Limitation Linear Derating From MAX to Null [470V≤Vdc≤520V] Linear Derating From MAX to Null [470V≤Vdc≤520V]

Maximum DC Input Current (Idcmax) 48 A 48 A 48 A 3

Maximum Input Short Circuit Current 58 A 58 A

DC Connection Type Screw Terminal Block Cable Glands

Screw Terminal Block 3 Knock-Outs: ¾”

Input ProtectionReverse Polarity Protection No No Input Over Voltage Protection - Varistor 4 4Generator Isolation Control Yes YesOutput SideAC Grid Connection Three Phase (Δ/Y) Three Phase (Δ/Y)Rated AC Power (Pacr) 10000 W 10000 WMaximum AC Output Power (Pacmax) 11000 W 11000 W 11000 WRated Grid AC Voltage (Vac,r) 400 V 208 V 480 VAC Voltage Range 320...480 V (1) 183-228 V 422 - 528 VMaximum Output AC Current (Iac,max) 16 A 30 A 14 ARated Frequency (fr) 50 Hz 60 HzFrequency Range (fmin...fmax) 47...53 Hz (2) 59.3...60.5 HzNominal Power Factor (Cosphiac,r) > 0.995 > 0.995Total Harmonic Distortion < 2% < 2%

AC Connection Type Screw Terminal Block Cable glands

Screw Terminal Block 3 Knock-Outs: ¾” or 1” (w/ring reducer)

Output ProtectionAnti-islanding protection According to local standard According to UL 1741/IEE1547Maximum AC Overcurrent Protection 20 A 35 A 20 A

Output Over Voltage Protection - Varistor 3, star connected to common point plus gas arrester to ground 3, star connected to common point plus gas arrester to ground

Operating PerformanceMaximum Efficiency (ηmax) 97.1% 96.7% 97.1%Stand-by Consumption < 8W < 8WCommunicationWired Local Monitoring PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD display 16 characters x 2 lines LCD displayEnvironmental

Ambient Temperature Range -25...+60°C /-13...140°F with derating above 45°C/113°F -25...+60°C /-13...140°F with derating above 45°C/113°F

Noise Emission < 50 dB(A) < 50 dB(A)Maximum Operating Altitude with Derating 2000 m / 6560 ft 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65 NEMA 4X Cooling Natural NaturalDimension (H x W x D) 716 mm x 645mm x 222 mm / 28.2” x 25.4” x 8.7” 716 mm x 645mm x 222 mm / 28.2” x 25.4” x 8.7”Weight 44.9 kg / 99 lb 44.9 kg / 99 lbSafetyIsolation Level HF Transformer HF TransformerMarking CE cCSAus

Safety and EMC standard EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12 UL 1741, CSA - C22.2 N. 107.1-01

Grid Standard Guideline ENEL, VDE 0126-1-1, AS4777, G59/2, EN 50438 IEEE 1547

Available Products VariantsStandard SSWI-10.0-I-OUTD-400 SSWI-10.0-I-OUTD-US-208 SSWI-10.0-I-OUTD-US-480

1. The AC voltage range may vary depending on specific country grid standard

2. The Frequency range may vary depending on specific country grid standard

3. Just for -480 version, the inverter applies current limit derating below 220V down to 2A/1A at 90V

Page 156: Renewable Energy Solutios

4000 & 7200 WIND INTERFACE

GENERAL SPECIFICATIONS

4000-WIND-INTERFACE-EU7200-WIND-INTERFACE-EU4000-WIND-INTERFACE7200-WIND-INTERFACE

156 AURORA WIND

Page 157: Renewable Energy Solutios

Conversion efficiency at rating: 99.4%Fused wind input to inverterAutomatic brake function above 530 VdcActivation function of external brake resistor Passive Three-Phase rectification

•••••

Power-One’s Aurora Wind Interface box is a key accessory within the small wind applications. The compact wind interface is designed to work in tandem with a small wind inverter for a grid-connected application.

Off ering 99.4% efficiency, the Wind Interface Box ‘passively rectifies’ the current produced by the turbine generator to feed the wind inverter.

Additionally it drives a dumpload braking system.

157AURORA WIND

FeaturesW

IND

Page 158: Renewable Energy Solutios

Block Diagram

158 AURORA WIND

HOUSE

FREQUENCY SIGNAL (OPTIONAL)

RS485

BRAKING

MECHANISM

SHOULD BE

IN PLACE

GRID

300 mA

30 mA

USB

BRAKE

RESISTOR

(OPTIONAL)

BLOCK DIAGRAM OF 7200W AND 4000W WIND-INTERFACE

BRIDGEDIODE OUT 1.1(+)

OUT 1.2(+)

OUT 1.3(+)

OUT 1.4(+)

OUT 2.1(-)

OUT 2.2(-)

OUT 2.3(-)

OUT 2.4(-)

DIVERSIONLOAD SWITCH

BRAKE (+)

BRAKE (-)

BULK CAPS

CONTROL

WIND SPEED (+)

WIND SPEED (-)

WINDSPEED

DETECTIONCIRCUIT

TO WINDINVERTER

TO DIVERSIONLOAD

TO WINDINVERTER

CONTROL CIRCUIT( WT(+) / WT(-) )

1

GND

GND

2

3

Page 159: Renewable Energy Solutios

159AURORA WIND

PARAMETER PVI-4000-WIND-INTERFACE

PVI-7200-WIND-INTERFACE

PVI-4000-WIND-INTERFACE-US

PVI-7200-WIND-INTERFACE-US

Input Side

AC Input Range (No damage) (Vacd,min...Vacd,max) 0...400 V 0...400 V 0...400 V 0...400 V

Operating AC Input Range (Vacmin...Vacmax) 35...400 V 35...400 V 35...400 V 35...400 V

Operating Frequency Range (fmin...fmax) 0...600 Hz (1) 0...600 Hz (1) 0...600 Hz (1) 0...600 Hz (1)

Maximum AC Input Current (Idcmax) 16.6 A 16.6 A 16.6 A 16.6 A

Maximum Current in Main Brake Resistor (IMBR,max) 30 A 30 A 30 A 30 A

Voltage Range in Main Brake Resistor (VMBRmin...VMBRmax) 0...600 V 0...600 V 0...600 V 0...600 V

Type of Inputs Connection Screw terminal block Cable Gland

Screw terminal block Cable Gland

Push Wire, Knock Out 3/4”, 3/8”

Push Wire, Knock Out 3/4”, 3/8”

Input protection

Input Over Voltage Portection - Varistor 3 3 3 3

Input Fuse Size 3 x 6 A 3 x 15 A (opt. 20 A) 3 x 6 A 3 x 15 A (opt. 20 A)

Output Side

Maximum Output Power (Pdcmax) 4.0 kW 7.2 kW 4.0 kW 7.2 kW

Output Voltage Range (Vdc,min...Vdc,max) 0...600 V 0...600 V 0...600 V 0...600 V

Maximum Output Current (Idc,max) 20 A 20 A 20 A 20 A

Type of Output Connection Screw terminal block Cable Gland

Screw terminal block Cable Gland

Push Wire, Knock Out 3/4”, 3/8”

Push Wire, Knock Out 3/4”, 3/8”

Output Protection

Output Over Voltage Yes Yes Yes Yes

Operating Performance

Peak Efficiency (ηpeak) 99.4 % 99.4 % 99.4 % 99.4 %

Stand-by Consumption < 3 W < 3 W < 3 W < 3 W

Communication

Local Monitoring System - - - -

Remote Control - - - -

User Interface - - - -

Environmental

Ambient Temperature Range -25...+55°C / -13...131°F -25...+55°C / -13...131°F -25...+55°C / -13...131°F -25...+55°C / -13...131°F

Relative Humidity < 100% Condensing < 100% Condensing < 100% Condensing < 100% Condensing

Noise Emission < 40 dB(A) < 40 dB(A) < 40 dB(A) < 40 dB(A)

Maximum Operating Altitude without Derating 2000 m / 6560 ft 2000 m / 6560 ft 2000 m / 6560 ft 2000 m / 6560 ft

Physical

Environmental Protection Rating IP 65 IP 65 NEMA 4X NEMA 4X

Cooling Natural Natural Natural Natural

Dimension (H x W x D) 252 mm x 287 mm x 85.7 mm / 9.9” x 11.3” x 3.37”

252 mm x 287 mm x 85.7 mm / 9.9” x 11.3” x 3.37”

252 mm x 287 mm x 85.7 mm / 9.9” x 11.3” x 3.37”

252 mm x 287 mm x 85.7 mm / 9.9” x 11.3” x 3.37”

Weight 1.8 kg / 4.0 lb 1.8 kg / 4.0 lb 1.8 kg / 4.0 lb 1.8 kg / 4.0 lb

Mounting System Wall Bracket Wall Bracket Wall Bracket Wall Bracket

Safety

Marking CE CE cCSAus cCSAus

Safety and EMC standard EN 50178, EN 61000-6-2, EN 61000-6-4

EN 50178, EN 61000-6-2, EN 61000-6-4

UL 1741, CSA - C22.2 N. 107.1-01

UL 1741, CSA - C22.2 N. 107.1-01

1.The frequency input is for single isolated driving source. When using wind tach, the available frequency range is 5...200Hz. The inverter also provides a +5V internal pull up max. 0.5mA.

Page 160: Renewable Energy Solutios

PVI-5000-TL-WPVI-6000-TL-W

GENERAL SPECIFICATIONS

PVI-5000-TL-OUTD-WPVI-6000-TL-OUTD-W PVI-5000-OUTD-US-WPVI-6000-OUTD-US-W

160 AURORA WIND

Page 161: Renewable Energy Solutios

Aurora grid-tie transformerless wind inverters off er a unique combination of high efficiencies, installer-friendly designs and long service life. A major selling point of the Aurora Wind inverter is its very wide input voltage range ensuring power is continuously harvested from the lightest breeze to the strongest wind.

The competitive initial acquisition costs matched with the high efficiencies of up to 97.0% significantly increase return on investment on wind-power installations.

This compact, weather-sealed inverter has a 16-point profile to best match the power curve of each wind turbine.

Single Phase OutputTransformerless operation for highest efficiencyPower curve customization with high granularity to reach high level of power production yieldOutdoor enclosure for unrestricted use under any environmental conditions Compact size and high power densityOptimized real time power curve tracking algorithm and improved energy harvestingHigh overload capability: works up the power max limits under most ambient conditionsCompatible with 25kW Wind InterfaceCompatible with 7200 Wind Interface

•••••••••

161AURORA WIND

FeaturesW

IND

Page 162: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

162 AURORA WIND

PVI-6000-OUTD-US-W

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

Effi

cien

cy, %

% of Rated Output Power

250 Vdc

400 Vdc

480 Vdc

BLOCK DIAGRAM OF PVI-5000-TL-OUTD-W AND PVI-6000-TL-OUTD-W

BOOST 1(DC/DC)

BOOST 2(DC/DC)

BULK CAPSINVERTER(DC/AC)

LINEFILTER

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

GRID PARALLELRELAY

L1

L3

PE

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

WIND SPEED INPUTWT (+)

WT (-)

Page 163: Renewable Energy Solutios

163AURORA WIND

PARAMETER PVI-5000-TL-OUTD-W PVI-6000-TL-OUTD-W

Input SideMaximum Absolute DC Input Voltage V(dc,abs) 600 V 600 VOperating DC Input Range (Vdcmin...Vdcmax) 50...580 V 50...580 VDC Input range at full power (Vfp,min...Vfp,max) 150...530 V 180...530 VDc Power Limitation Linear Derating From MAX to Null [530V≤Vdc≤580V] Linear Derating From MAX to Null [530V≤Vdc≤580V]Maximum DC Input Current (Idcmax) 36 A 36 AMaximum Input Short Circuit Current 44 A 44 A

DC Connection Type Screw Terminal Block Cable Glands

Screw Terminal Block Cable Glands

Input ProtectionReverse Polarity Protection No No Input Over Voltage Protection - Varistor 4 4Generator Isolation Control Yes YesOutput SideAC Grid Connection Single Phase Single PhaseRated AC Power (Pacr) 5000 W(3) 6000 WMaximum AC Output Power (Pacmax) 5000 W 6000 WRated Grid AC Voltage (Vac,r) 230 V 230 VAC Voltage Range 180...264 V (1) 180...264 V (1)

Maximum Output AC Current (Iac,max) 25 A 30 ARated Frequency (fr) 50 Hz 50 HzFrequency Range (fmin...fmax) 47...53 Hz (2) 47...53 Hz (2)

Nominal Power Factor (Cosphiac,r) > 0.995 > 0.995Total Harmonic Distortion < 2% < 2%

AC Connection Type Screw Terminal Block Cable Glands

Screw Terminal Block Cable Glands

Output ProtectionAnti-islanding protection According to local standard According to local standardMaximum AC Overcurrent Protection 32 A 40 AOutput Over Voltage Protection - Varistor 2 (L-N/L-PE) 2 (L-N/L-PE)Operating PerformanceMaximum Efficiency (ηmax) 97.0% 97.0%Stand-by Consumption < 8W < 8WCommunicationWired Local Monitoring PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD display 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+ 60°C /-13...140°F with derating above 50°C/122°F -25...+ 60°C /-13...140°F with derating above 50°C/122°FNoise Emission < 50 dB(A) < 50 dB(A)Maximum Operating Altitude with Derating 2000 m / 6560 ft 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65 IP 65 Cooling Natural NaturalDimension (H x W x D) 810mm x 325mm x 228mm / 31.9” x 12.8” x 8.7” 810mm x 325mm x 228mm / 31.9” x 12.8” x 8.7”Weight 27 kg / 59.5 lb 27 kg / 59.5 lbSafetyIsolation Level Transformerless TransformerlessMarking CE CE

Safety and EMC standard EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12

EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12

Grid Standard VDE 0126-1-1, G59/2, EN 50438 DK 5940, VDE 0126-1-1, G59/2, EN 50438, RD1663, AS4777(4)

Available Products VariantsStandard PVI-5000-TL-OUTD-W PVI-6000-TL-OUTD-W

1. The AC voltage range may vary depending on specific country grid standard

2. The Frequency range may vary depending on specific country grid standard

3. Limited to 4600 W for Germany

4. Add suffix -AU to product description

Page 164: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

164 AURORA WIND

PVI-6000-OUTD-US-W

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

Effi

cien

cy, %

% of Rated Output Power

250 Vdc

400 Vdc

480 Vdc

BLOCK DIAGRAM OF PVI-5000-TL-OUTD-W AND PVI-6000-TL-OUTD-W

BOOST 1(DC/DC)

BOOST 2(DC/DC)

BULK CAPSINVERTER(DC/AC)

LINEFILTER

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

GRID PARALLELRELAY

L1

L3

PE

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

WIND SPEED INPUTWT (+)

WT (-)

Page 165: Renewable Energy Solutios

165AURORA WIND

PARAMETER PVI-6000-OUTD-US-W

Input SideMaximum Absolute DC Input Voltage V(dc,abs) 600 VOperating DC Input Range (Vdcmin...Vdcmax) 50...580 VDC Input range at full power (Vfp,min...Vfp,max) 180...530 VDc Power Limitation Linear Derating From MAX to Null [530V≤Vdc≤580V]Maximum DC Input Current (Idcmax) 36 AMaximum Input Short Circuit Current 44 A

DC Connection Type Screw Terminal Block 3 Knock-Outs: 1 ½” or 1” (w/ Ring Red.)

Input ProtectionReverse Polarity Protection No Input Over Voltage Protection - Varistor 4Generator Isolation Control YesOutput Side 208 240 277AC Grid Connection Single Phase / Split PhaseRated AC Power (Pacr) 6000 WMaximum AC Output Power (Pacmax) 6000 WRated Grid AC Voltage (Vac,r) 208 V 240 V 277 VAC Voltage Range 183...228 V 211...264 V 244...304 VMaximum Output AC Current (Iac,max) 30 A 28 A 24 ARated Frequency (fr) 60 HzFrequency Range (fmin...fmax) 59.3...60.5 HzNominal Power Factor (Cosphiac,r) > 0.995Total Harmonic Distortion < 2%

AC Connection TypeScrew Terminal Block

3 Knock-Outs: 1 ½” or 1” (w/ring reducer) Wire Size: Max. AWG8

Output Protection 208 240 277Anti-islanding protection According to UL 1741/IEE1547Maximum AC Overcurrent Protection 40 A 35 A 30 AOutput Over Voltage Protection - Varistor 2 (L-N/L-PE)Operating PerformanceMaximum Efficiency (ηmax) 97.0%Stand-by Consumption < 8WCommunicationWired Local Monitoring PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+ 60°C /-13...140°F with derating above 50°C/122°FNoise Emission < 50 dB(A)Maximum Operating Altitude with Derating 2000 m / 6560 ftPhysical Environmental Protection Rating NEMA 4X Cooling NaturalDimension (H x W x D) 810mm x 325mm x 228mm / 31.9” x 12.8” x 8.7”Weight 26.3 kg / 58 lbSafetyIsolation Level TransformerlessMarking cCSAusSafety and EMC standard UL 1741, CSA - C22.2 N. 107.1-01Grid Standard IEEE 1547Available Products VariantsStandard PVI-6000-OUTD-US-W

Page 166: Renewable Energy Solutios

SSWI-3.8-ISSWI-4.6-I

GENERAL SPECIFICATIONS

SSWI-3.8-I-OUTDSSWI-4.6-I-OUTDSSWI-3.8-I-OUTD-USSSWI-4.6-I-OUTD-US

166 AURORA WIND

NEW

Page 167: Renewable Energy Solutios

167AURORA WIND

Single Phase OutputGalvanic isolation by high frequency transformerPower curve customization with high granularity to reach high level of power production yieldOutdoor enclosure for unrestricted use under any environmental conditions Compact size and high power densityOptimized real time power curve tracking algorithm and improved energy harvestingHigh overload capability: works up the power max limits under most ambient conditionsEach inverter is set on specifi c grid codes which can be selected in the fi eldCompatible with 25kW Wind InterfaceCompatible with 7200 Wind Interface

••••••••••

This isolated inverter is optimized for use in small wind. applications. This inverter has also been designed to serve all countries and regions with specific field-configurable set-ups available for all major country grid codes and display languages.

The competitive initial acquisition costs matched with the high efficiencies of up to 96.9% wide input range significantly increase return on investment on wind-power installations.

Its high frequency isolated topology allows this unit to be lightweight and compact in size to help with transportation and installation. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.

FeaturesW

IND

Page 168: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

168 AURORA WIND

BLOCK DIAGRAM OF SSWI-3.8-I-OUTD AND SSWI-4.6-I-OUTD

SSWI-3.8-OUTD-US-W SSWI-4.6-OUTD-US-W

200 Vdc340 Vdc416 Vdc

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

200 Vdc

340 Vdc

416 Vdc

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

E�ci

ency

, %

% of Rated Output Power

200 Vdc

340 Vdc

416 Vdc

BOOST 1(DC/DC)

BOOST 2(DC/DC)

HFTRANSFORMER

HFTRANSFORMER

BULK CAPSINVERTER(DC/AC)

LINEFILTER

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

GRID PARALLELRELAY

L1

L2

L3

N

PE

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

WIND SPEED INPUTWT (+)

WT (-)

OPTOISOLATOR

Page 169: Renewable Energy Solutios

169AURORA WIND

PARAMETER SSWI-3.8-I-OUTD SSWI-4.6-I-OUTD

Input SideMaximum Absolute DC Input Voltage V(dc,abs) 520 V 520 VOperating DC Input Range (Vdcmin...Vdcmax) 90...520 V 90...520 VDC Input range at full power (Vfp,min...Vfp,max) 160...470 V 200...470 VDc Power Limitation Linear Derating From MAX to Null [470V≤Vdc≤520V] Linear Derating From MAX to Null [470V≤Vdc≤520V]Maximum DC Input Current (Idcmax) 25 A 28 AMaximum Input Short Circuit Current 44 A 44 A

DC Connection Type Screw Terminal Block Cable Glands

Screw Terminal Block Cable Glands

Input ProtectionReverse Polarity Protection No No Input Over Voltage Protection - Varistor 4 4Generator Isolation Control Yes YesOutput SideAC Grid Connection Single Phase Single Phase Rated AC Power (Pacr) 3800 W 4600 WMaximum AC Output Power (Pacmax) 4200 W 5000 WRated Grid AC Voltage (Vac,r) 230 V 230 VAC Voltage Range 180...264 V (1) 180...264 V (1)

Maximum Output AC Current (Iac,max) 18.2 A(2) 22.5 ARated Frequency (fr) 50 Hz 50 HzFrequency Range (fmin...fmax) 47...53 Hz (3) 47...53 Hz (2)

Nominal Power Factor (Cosphiac,r) > 0.995 > 0.995Total Harmonic Distortion < 2% < 2%

AC Connection Type Screw Terminal Block Cable Glands

Screw Terminal Block Cable Glands

Output ProtectionAnti-islanding protection According to local standard According to local standardMaximum AC Overcurrent Protection 20 A 25 AOutput Over Voltage Protection - Varistor 2 (L-N/L-PE) 2 (L-N/L-PE)Operating PerformanceMaximum Efficiency (ηmax) 96.8% 96.8%Stand-by Consumption < 8W < 8WCommunicationWired Local Monitoring PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.) PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.) PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.) PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD display 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+60°C /-13...140°F with derating above 45°C/113°F -25...+60°C /-13...140°F with derating above 45°C/113°FNoise Emission < 50 dB(A) < 50 dB(A)Maximum Operating Altitude with Derating 2000 m / 6560 ft 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65 IP 65Cooling Natural NaturalDimension (H x W x D) 712mm x 325mm x 222mm / 28” x 12.8” x 8.7” 712mm x 325mm x 222mm / 28” x 12.8” x 8.7” Weight 20 kg / 44 lb 20 kg / 44 lb SafetyIsolation Level HF Transformer HF TransformerMarking CE CE

Safety and EMC standard EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12

EN 50178, AS/NZS3100, AS/NZS 60950, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12

Grid Standard Guideline ENEL, VDE 0126-1-1, AS4777, G83/1, EN 50438 Guideline ENEL, VDE 0126-1-1, AS4777, G59/2, EN 50438Available Products VariantsStandard SSWI-3.8-I-OUTD SSWI-4.6-I-OUTD

1. The AC voltage range may vary depending on specific country grid standard

2. Maximum Output Current Limited to 16A for G83/1 version

3. The Frequency range may vary depending on specific country grid standard

Page 170: Renewable Energy Solutios

170 AURORA WIND

PARAMETER SSWI-3.8-I-OUTD-US

Input SideMaximum Absolute DC Input Voltage V(dc,abs) 520 VOperating DC Input Range (Vdcmin...Vdcmax) 90...520 VDC Input range at full power (Vfp,min...Vfp,max) 200...470 VDc Power Limitation Linear Derating From MAX to Null [470V≤Vdc≤520V]Maximum DC Input Current (Idcmax) 25 AMaximum Input Short Circuit Current 31.2 A

DC Connection Type Screw Terminal Block 3 Knock-Outs: ¾”

Input ProtectionReverse Polarity Protection No Input Over Voltage Protection - Varistor 4Generator Isolation Control YesOutput Side 208 240 277AC Grid Connection Single Phase / Split PhaseRated AC Power (Pacr) 3300 W 3800 WMaximum AC Output Power (Pacmax) 3300 W 3800 W 4200 WRated Grid AC Voltage (Vac,r) 208 V 240 V 277 VAC Voltage Range 183...228 V 211...264 V 244...304 VMaximum Output AC Current (Iac,max) 16 A 16 A 16 ARated Frequency (fr) 60 HzFrequency Range (fmin...fmax) 59.3...60.5 HzNominal Power Factor (Cosphiac,r) > 0.995Total Harmonic Distortion < 2%

AC Connection Type Screw Terminal Block 3 Knock-Outs: ¾”

Output ProtectionAnti-islanding protection According to UL 1741/IEE1547Maximum AC Overcurrent Protection 20 AOutput Over Voltage Protection - Varistor 2 (L-N/L-PE)Operating PerformanceMaximum Efficiency (ηmax) 96.9%Stand-by Consumption < 8WCommunicationWired Local Monitoring PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+60°C /-13...140°F with derating above 45°C/113°FNoise Emission < 50 dB(A)Maximum Operating Altitude with Derating 2000 m / 6560 ftPhysical Environmental Protection Rating NEMA 4X Cooling NaturalDimension (H x W x D) 712mm x 325mm x 222mm / 28” x 12.8” x 8.7” Weight 20 kg / 44 lb SafetyIsolation Level HF TransformerMarking cCSAusSafety and EMC standard UL 1741, CSA - C22.2 N. 107.1-01Grid Standard IEEE 1547Available Products VariantsStandard SSWI-3.8-I-OUTD-US

Page 171: Renewable Energy Solutios

171AURORA WIND

PARAMETER SSWI-4.6-I-OUTD-US

Input SideMaximum Absolute DC Input Voltage V(dc,abs) 520 VOperating DC Input Range (Vdcmin...Vdcmax) 90...520 VDC Input range at full power (Vfp,min...Vfp,max) 200...470 VDc Power Limitation Linear Derating From MAX to Null [470V≤Vdc≤520V]Maximum DC Input Current (Idcmax) 28 AMaximum Input Short Circuit Current 34 A

DC Connection Type Screw Terminal Block 3 Knock-Outs: ¾”

Input ProtectionReverse Polarity Protection No Input Over Voltage Protection - Varistor 4Generator Isolation Control YesOutput Side 208 240 277AC Grid Connection Single Phase / Split PhaseRated AC Power (Pacr) 4600 WMaximum AC Output Power (Pacmax) 5000 W 5000 W 5000 WRated Grid AC Voltage (Vac,r) 208 V 240 V 277 VAC Voltage Range 183...228 V 211...264 V 244...304 VMaximum Output AC Current (Iac,max) 23 A 20 A 20 A Rated Frequency (fr) 60 HzFrequency Range (fmin...fmax) 59.3...60.5 HzNominal Power Factor (Cosphiac,r) > 0.995Total Harmonic Distortion < 2%

AC Connection Type Screw Terminal Block 3 Knock-Outs: ¾”

Output Protection 208 240 277Anti-islanding protection According to UL 1741/IEE1547Maximum AC Overcurrent Protection 30 A 25 A 25 AOutput Over Voltage Protection - Varistor 2 (L-N/L-PE)Operating PerformanceMaximum Efficiency (ηmax) 96.9%Stand-by Consumption < 8WCommunicationWired Local Monitoring PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+60°C /-13...140°F with derating above 45°C/113°FNoise Emission < 50 dB(A)Maximum Operating Altitude with Derating 2000 m / 6560 ftPhysical Environmental Protection Rating NEMA 4X Cooling NaturalDimension (H x W x D) 712mm x 325mm x 222mm / 28” x 12.8” x 8.7” Weight 20 kg / 44 lb SafetyIsolation Level HF TransformerMarking cCSAusSafety and EMC standard UL 1741, CSA - C22.2 N. 107.1-01Grid Standard IEEE 1547Available Products VariantsStandard SSWI-4.6-I-OUTD-US

Page 172: Renewable Energy Solutios

PVI-3.0-TL-WPVI-3.6-TL-WPVI-4.2-TL-W

GENERAL SPECIFICATIONS

PVI-3.0-TL-OUTD-WPVI-3.6-TL-OUTD-WPVI-4.2-TL-OUTD-W PVI-3.0-OUTD-US-WPVI-3.6-OUTD-US-WPVI-4.2-OUTD-US-W

172 AURORA WIND

Page 173: Renewable Energy Solutios

Single Phase OutputTransformerless operation for highest efficiencyPower curve customization with high granularity to reach high level of power production yieldOutdoor enclosure for unrestricted use under any environmental conditions Compact size and high power densityOptimized real time power curve tracking algorithm and improved energy harvestingHigh overload capability: works up the power max limits under most ambient conditionsCompatible with 25kW Wind InterfaceCompatible with 7200 Wind InterfaceCompatible with 4000 Wind Interface

••••••••••

Aurora grid-tie transformerless wind inverters off er a unique combination of high efficiencies, installer-friendly designs and long service life. A major selling point of the Aurora Wind inverter is its very wide input voltage range ensuring power is continuously harvested from the lightest breeze to the strongest wind.

The competitive initial acquisition costs matched with the high efficiencies of up to 96.9% significantly increase return on investment on wind-power installations.

This compact, weather-sealed inverter has a programmable 16-point profile which allows a tight match for any compatible permanent magnet turbine.

173AURORA WIND

FeaturesW

IND

Page 174: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

174 AURORA WIND

PVI-3.6-TL-OUTD-W PVI-4.2-TL-OUTD-W

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

Effi

cien

cy, %

% of Rated Output Power

200 Vdc

340 Vdc

480 Vdc

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

Effi

cien

cy, %

% of Rated Output Power

200 Vdc

340 Vdc

480 Vdc

BLOCK DIAGRAM OF PVI-3.0-TL-OUTD-W, PVI-3.6-TL-OUTD-W AND PVI-4.2-TL-OUTD-W

BOOST 1(DC/DC)

BOOST 2(DC/DC)

BULK CAPSINVERTER(DC/AC)

LINEFILTER

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

GRID PARALLELRELAY

L1

L3

PE

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

WIND SPEED INPUTWT (+)

WT (-)

Page 175: Renewable Energy Solutios

175AURORA WIND

PARAMETER PVI-3.0-TL-OUTD-W PVI-3.6-TL-OUTD-W PVI-4.2-TL-OUTD-W

Input SideMaximum Absolute DC Input Voltage V(dc,abs) 600 VOperating DC Input Range (Vdcmin...Vdcmax) 50...580 VDC Input range at full power (Vfp,min...Vfp,max) 160...530 V 120...530 V 140...530 VDc Power Limitation Linear Derating From MAX to Null [530V≤Vdc≤580V]Maximum DC Input Current (Idcmax) 20 A 32 A 32 AMaximum Input Short Circuit Current 25 A 40 A 40 A

DC Connection Type Screw Terminal Block Cable Glands

Input ProtectionReverse Polarity Protection No Input Over Voltage Protection - Varistor 4Generator Isolation Control YesOutput SideAC Grid Connection Single phaseRated AC Power (Pacr) 3000 W 3600 W 4200 WMaximum AC Output Power (Pacmax) 3300 W 4000 W 4600 WRated Grid AC Voltage (Vac,r) 230 VAC Voltage Range 180...264 V (1)

Maximum Output AC Current (Iac,max) 14.5 A 17.2 A(3) 20 ARated Frequency (fr) 50 HzFrequency Range (fmin...fmax) 47...53 Hz (2)

Nominal Power Factor (Cosphiac,r) > 0.995Total Harmonic Distortion < 2%

AC Connection Type Screw Terminal Block Cable Glands

Output ProtectionAnti-islanding protection According to local standardMaximum AC Overcurrent Protection 16 A 19 A 22 AOutput Over Voltage Protection - Varistor 2 (L-N/L-PE)Operating PerformanceMaximum Efficiency (ηmax) 96.8%Stand-by Consumption < 8WCommunicationWired Local Monitoring PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+ 60°C/-13...140°F with derating above 55°C/131°FNoise Emission < 50 dB(A)Maximum Operating Altitude with Derating 2000 m / 6560 ftPhysical Environmental Protection Rating IP 65Cooling Natural Dimension (H x W x D) 618mm x 325mm x 222mm / 24.3” x 12.8” x 8.7”Weight 17 kg / 37.4 lbSafetyIsolation Level TransformerlessMarking CESafety and EMC standard EN 50178, EN61000-6-2, EN61000-6-4, EN61000-3-11, EN61000-3-12

Grid Standard DK 5940, VDE 0126-1-1, G83/1, EN 50438, RD1663, AS4777(5)

DK 5940, VDE 0126-1-1, G83/1, G59/2(4), EN 50438, RD1663, AS4777(5)

DK 5940, VDE 0126-1-1, G59/2, EN 50438, RD1663, AS4777(5)

Available Products VariantsStandard PVI-3.0-TL-OUTD-W PVI-3.6-TL-OUTD-W PVI-4.2-TL-OUTD-W

1. The AC voltage range may vary depending on specific country grid standard

2. The Frequency range may vary depending on specific country grid standard

3. Maximum output current limited to 16A for G83/1 version

4. Ask sales for availability

5. Add suffix -AU to product description

Page 176: Renewable Energy Solutios

Block Diagram and Effi ciency Curves

176 AURORA WIND

PVI-3.6-OUTD-US-W PVI-4.2-OUTD-US-W

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

Effi

cien

cy, %

% of Rated Output Power

200 Vdc

340 Vdc

480 Vdc

90

91

92

93

94

95

96

97

98

99

100

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

Effi

cien

cy, %

% of Rated Output Power

200 Vdc

340 Vdc

480 Vdc

BLOCK DIAGRAM OF PVI-3.0-OUTD-W, PVI-3.6-OUTD-W AND PVI-4.2-OUTD-W FOR NORTH AMERICA

BOOST 1(DC/DC)

BOOST 2(DC/DC)

BULK CAPSINVERTER(DC/AC)

LINEFILTER

DC/DCDSP

CONTR.

DC/ACDSP

CONTR.

µP

CONTROL CIRCUIT

GRID PARALLELRELAY

L1

L3

PE

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

IN1.1(+)

IN1.2(+)

IN1.1(-)

IN1.2(-)

RS485

+ T/R

- T/R

RTN

REMOTE CONTROL

+ R

- R

ALARM

N.C

N.O

C

WIND SPEED INPUTWT (+)

WT (-)

Page 177: Renewable Energy Solutios

177AURORA WIND

PARAMETER PVI-3.0-OUTD-US-W PVI-3.6-OUTD-US-W PVI-4.2-OUTD-US-W

Input SideMaximum Absolute DC Input Voltage V(dc,abs) 600 VOperating DC Input Range (Vdcmin...Vdcmax) 50...580 VDC Input range at full power (Vfp,min...Vfp,max) 200...530 V 220...530 V 200...530 VDc Power Limitation Linear Derating From MAX to Null [530V≤Vdc≤580V]Maximum DC Input Current (Idcmax) 20 A 32 A 32 AMaximum Input Short Circuit Current 25 A 40 A 40 A

DC Connection Type Screw Terminal Block 3 Knock-Outs: 1 ½” or 1” (w/ Ring Red.)

Input ProtectionReverse Polarity Protection No Input Over Voltage Protection - Varistor 4Generator Isolation Control YesOutput Side 208 240 277 208 240 277 208 240 277AC Grid Connection Single Phase / Split PhaseRated AC Power (Pacr) 3000 W 3600 W 4200 WMaximum AC Output Power (Pacmax) 3000 W 3300 W 3300 W 3600 W 4000 W 4000 W 4200 W 4600 W 4600 WRated Grid AC Voltage (Vac,r) 208 V 240 V 277 V 208 V 240 V 277 V 208 V 240 V 277 VAC Voltage Range 183...228 V 211...264 V 244...304 V 183...228 V 211...264 V 244...304 V 183-228 V 211-264 V 244-304 VMaximum Output AC Current (Iac,max) 14.5 A 14.5 A 12.0 A 17.2 A 16 A 16 A 20 A 20 A 20 ARated Frequency (fr) 60 HzFrequency Range (fmin...fmax) 59.3...60.5 HzNominal Power Factor (Cosphiac,r) > 0.995Total Harmonic Distortion < 2%

AC Connection Type Screw Terminal Block 3 Knock-Outs: 1 ½” or 1” (w/ring reducer)

Output Protection 208 240 277 208 240 277 208 240 277Anti-islanding protection According to UL 1741/IEE1547Maximum AC Overcurrent Protection 20 A 20 A 15 A 25 A 20 A 20 A 25 A 25 A 25 AOutput Over Voltage Protection - Varistor 2 (L-N/L-PE)Operating PerformanceMaximum Efficiency (ηmax) 96.8%Stand-by Consumption < 8WCommunicationWired Local Monitoring PVI-USB-RS485_223 (opt.), PVI-DESKTOP (opt.)Remote Monitoring PVI-AEC-EVO (opt.), AURORA-UNIVERSAL (opt.)Wireless Local Monitoring PVI-DESKTOP (opt.) with PVI-RADIOMODULE (opt.)User Interface 16 characters x 2 lines LCD displayEnvironmentalAmbient Temperature Range -25...+ 60°C/-13...140°F with derating above 55°C/131°FNoise Emission < 50 dB(A)Maximum Operating Altitude with Derating 2000 m / 6560 ftPhysical Environmental Protection Rating NEMA 4X Cooling Natural Dimension (H x W x D) 618mm x 325mm x 222mm / 24.3” x 12.8” x 8.7”Weight 18 kg / 39.6 lbSafetyIsolation Level TransformerlessMarking cCSAusSafety and EMC standard UL 1741, CSA - C22.2 N. 107.1-01Grid Standard IEEE 1547Available Products VariantsStandard PVI-3.0-OUTD-US-W PVI-3.6-OUTD-US-W PVI-4.2-OUTD-US-W

Page 178: Renewable Energy Solutios

Power-One is dedicated to making sure that each of our customers enjoy uninterrupted use and production from their Aurora Inverter. By purchasing an inverter from Power-One you have joined with a team that is dedicated to making your life easy.

From startup and commissioning to trouble-shooting and fault correction, our technical support team members are ready and willing to assist in answering all your installation and technical questions. At Power-One, we want to ensure that your Inverter is as productive as possible at all times.

With this in mind, we gladly off er a number of key services detailed on the following pages.

Power-One is continually developing new and unique services to off er our customers in order to enhance your experience and improve your productive use of our product.

More details on each program within the Aurora Service system can be gained by meeting with your local representative.

For Service contact details and information on Return and Repairs please see page 201.

Martin RogersVice President, Global Services

178 AURORA SERVICE

Page 179: Renewable Energy Solutios

179AURORA SERVICE

SERV

ICE

SERVICE

Page 180: Renewable Energy Solutios

180 AURORA SERVICE

Page 181: Renewable Energy Solutios

SERV

ICE

Aurora Advantage Programs include High End Performance Guarantees, Software and Communication integration and upgrades, Variable Up Time and Productive Time Assurance Plans, Remote Monitoring & Reporting, Field and Site Optimization, Lifetime repair/replace, Ownership Transfer Reviews, Site Certification, On Site System Maintenance, Pre-Pack Maintenance, Start Up and Commissioning, Advanced System Integration, System Maximization, and On Site Emergency Intervention.

The Advantage program allows you to custom tailor your Power-One support to meet you or your clients needs. From our full a la carte menu you can pick and choose those services that best cover your current and future needs.

Performance Guarantees for Central and grouped string inverters will give you the ultimate peace of mind. We will ensure productive up-time tailored specifically to your financial obligations and your corporate programs. With a combination of our off er (modularity) and our service teams located around the world, we can help you reduce or eliminate down-time from a system failure.

Communication and software update programs will help you keep in touch and up to date, the advanced service allows you to have constant monitoring, system upgrades and integration services available for your complete power plant.

Long-term and lifetime programs were developed to ensure the long term productivity of your plant. Rest assured that Power-One will have the parts, the people and the systems in place to help you maintain a long term productive plant.

Maintenance programs can be tailor fit to your installation. Whether we perform on-site system maintenance or you choose our self maintenance program plans, we can help you ensure a lifetime of production for the right cost.

Commissioning services will help you start out right. With our completesystem check and set up plan you have the comfort of knowing we are with you every step of the way. Through or comprehensive start up procedures you will see that each component and the combined system are working properly from day one.

ADVANTAGE

181AURORA SERVICE

Page 182: Renewable Energy Solutios

182 AURORA SERVICE

Page 183: Renewable Energy Solutios

SERV

ICE

The Aurora Assure Program includes Normal Warranty Coverage, Extended Warranty Coverage, Technical Support and Call Center, On Line Support, No Fault Warranty, Mid-life Warranty Extensions, End-of-life Management, End-of-life Replacement Discount, Monitoring & System Integration.

When making a large investment it is important for you to ensure the longevity and high level of production of your facility. To do this one of the first steps you need to take is to work with a strong global company with years of operating experience in the inverter business. Power-One off ers the best possible solution.

Standard warranties from 5 to 10 years and warranty extensions of up to 20 total years, ensure the longevity and confidence that you need.

Call Center support is available from 8am-5pm every working day and the online support and FAQ system is available for you 24/7. You may also log into the system and advise us of any questions you may have and we will gladly respond within the next working day.

Our new online system will soon allow you to register your warranty and track your service level agreements. Any time day or night, with our fast track system you will be able to determine where your inverter is in our system at anytime during repair, ask any question you may have and request further technical support as necessary.

Online training programs will also be made available to registered owners or installers.

ASSURE

183AURORA SERVICE

Page 184: Renewable Energy Solutios

184 AURORA SERVICE

Page 185: Renewable Energy Solutios

SERV

ICE

We think it’s time for you to join us an Alliance member. More than a club, Aurora Alliance is a partnership.

Membership with an industry leader has its advantages. Through our Alliance Membership, you become a part of our future.

We will work with you to help increase your knowledge and capability. You will learn more about layout and design, engineering support, knowledge base access, direct line technical support, training discount, enhanced sales programs, discount on specific service off ers portal based warranty registration, marketing material and more.

The Aurora Alliance programs will keep you up to date on new Aurora off ers, help you market your company with the advantage of Aurora collateral and allow you to enjoy many industry specific conversations with other Alliance members, all hosted by Power-One.

Always check with your local Power-One Representative for Pricing and Programs News

185AURORA SERVICE

ALLIANCE

Page 186: Renewable Energy Solutios

186 AURORA SERVICE

Page 187: Renewable Energy Solutios

SERV

ICE

By joining the Aurora Academy you become an informed member of an elite team. Included in this program are customer and installer specific training programs:

On-Site Training, arranged to help tailor the training to your team’s specific needs and site specific installation, cuts to the core allowing you to learn in a live classroom. This training is one of the most eff ective means to ensure your power plant maintains a high level of productivity.

Certification training programs are designed to bring you and your team to the next level of proficiency. Learn the ins and outs of the PV and Wind systems obtain certification and access to specific FAQs. Develop your own Train the Trainer program.

Power-One also off ers safety training, site maintenance training and other unique programs develop to help you improve your plants performance.

Power-One’s Regional Training Centers will off er a full calendar of training events. Our course work will be off ered live and online for your convenience.

ACADEMY

187AURORA SERVICE

Page 188: Renewable Energy Solutios

188 GLOBAL MARKET OVERVIEW

Page 189: Renewable Energy Solutios

189GLOBAL MARKET OVERVIEW

GLOBAL MARKET OVERVIEW

Page 190: Renewable Energy Solutios

190 GLOBAL MARKET OVERVIEW

Europe, Middle East and Africa (EMEA) Market Overview

Page 191: Renewable Energy Solutios

191GLOBAL MARKET OVERVIEW

In the past few years, the EMEA market has represented Power-One’s spring-board into the renewable energy market.

Thanks to the opportunities presented by the diff erent regional markets in our territory, we have grown to be the second largest inverter manufacturer in the world. In 2010, EMEA’s market topped an impressive 16 GW worth of new installations with Germany and Italy being the leading countries with about 8.5GW and 5.5GW respectively.

As more and more photovoltaic installations are being deployed within EMEA, governments are issuing new laws and regulations to tighten feed-in-tariff s to try and drive our market towards full sustainability (grid parity).

This opens up several new opportunities and also some challenges. I am confident that Power-One is ready for them.

Our network of partners and distributors has reached a degree of penetration throughout Italy, Germany, France, Spain, Portugal, United Kingdom, Israel and the BeNeLux, which is second to none.

We are still investing in our channel, not only to enlarge our sales and service structures in those countries but also in to open up branch offices in Greece, in the Arab Emirates and in several countries in Africa. We firmly believe that the continued expansion in new markets will bring Power-One the strength and the experience which will be needed to sustain the competitive challenges that lie ahead of us.

As you fl ip the pages of this brochure, you will see a whole host of new products that we have prepared to the usual technical and technological excellence while keeping a very close eye to competitiveness and ease of use. We are proud of our new product off ering and we are convinced that it will meet the market’s taste and expectations.

Finally, I would like to take this opportunity to thank our entire sales force, our distribution partners, our customer service people, our technical groups and all of the customers who have placed their trust in our products and services.

We wouldn’t be where we are without you and you can be sure of our continued commit-ment to provide you with best-in-class technology, fl exibility, competitiveness and service.

Averaldo FarriVice President Sales, EMEA

Page 192: Renewable Energy Solutios

192 GLOBAL MARKET OVERVIEW

North America is quickly becoming the largest PV market in the world. Each month, analysts are predicting even larger totals for 2011 and beyond, currently greater than 2GW. This is twice what was predicted last year. With the price of oil again on the rise, these numbers will continue to increase.

Power-One continues to increase market share in all global markets. We attained the #2 position and continue to distance ourselves those behind. Diff erentiated product features along with the highest reliability are making Power-One the inverter of choice. Our plan to have local manufacturing in each of the three major geographies has been executed.

In North America, the Phoenix, Arizona facility is now fully operational. Scarborough, Ontario also continues to expand its support of the Canadian marketplace with each new inverter we introduce. Having local manufacturing is key to our success by providing immediate customer support, local inventory, and producing products that comply with local incentive requirements.

The Power-One Aurora family of inverters continues to expand in North America. Over the past year, we have launched a new line of isolated string inverters, the modular Central inverter platform, turn-key utility scale inverters, and the world’s most popular three-phase string inverter line.

Demand for our transformerless string inverters continue to grow as customers realize the advantages this topology brings. Power-One market share will continue to grow as installers and owners recognize the value of design fl exibility, simplified installation, robust engineering, best-in-class efficiency, and the highest reliability.

We will continue to off er innovative new products to meet evolving requirements of the North American market.

All of us at Power-One are excited to be part of the Renewable Energy industry during this time of unprecedented growth. We look forward to helping our partners continue to be successful by providing the best products and services available. The future is destined to be bright.

Kent SheldonVice President Sales, NA

Page 193: Renewable Energy Solutios

193GLOBAL MARKET OVERVIEW

North American (NA) Market Overview

Page 194: Renewable Energy Solutios

194 GLOBAL MARKET OVERVIEW

Asia is a market with a vibrant mix of cultures and business challenges which are unique and full of unpredictables. At Power-One Asia, we cover more than half the population of the globe and a vast area with high growth potential.

In China, where we have just opened our brand new RE factory, the market requires mainly central inverters and has to be qualifi ed by CQC. Our PVI-250-TL and PVI-500-TL are well positioned for the China market and currently we are engaging in a lot of brand and product promotion to try to gain traction. In Australia, our string inverter has gained number one market share in 2010. With the introduction of the new 2kW inverter, we should maintain our position in 2011. In India, PVI-250 and PVI-500 have already made in road into a few solar farm projects which are bases on the CQC stan-dard. Soon our Indian offi ce will also be set up to cope with upcoming demands. The earthquake and nuclear crisis in Japan has shocked the market place whereby the market has temporary went to hibernation. We are seeking to work with local partners to get our string inverter certifi ed so when the market return, we will be able to catch the initial waves.

Asia is the most densely populated area on earth and yet consumption of natural resources accounts for much less than the western world. And people in this part of the world do really adopt the philosophy of living with the nature. So conservation of energy and natural resources would be a main theme of most people’s daily living.

The appreciation of good technology is also a part of the culture in Asia. Power-One positions here with good history and infrastructure in place to tackle the rising demand of green energy. With the opening of our RE factory in Shenzhen, China, we can now deliver Asia-made products to the market with good technology and timely services. We believe that we can capitalize on the growing market and make good inroads with our new 250kW and 500kW utility-grade products which will bring good cost-per-watt value to our customers.

Continue to ‘Aim High’ is part Power-One’s sales team in Asia. We will strive our eff orts with the dedicated and focus team in gaining market share in this part of the world. And diff erent spices will need to be deployed with our strategies to win.

Steve CheungVice President Sales, APAC

Page 195: Renewable Energy Solutios

195GLOBAL MARKET OVERVIEW

Asia Pacific Market (APAC) Overview

Page 196: Renewable Energy Solutios

196 CONTACTS

Page 197: Renewable Energy Solutios

197CONTACTS

CONTACTS

Page 198: Renewable Energy Solutios

198 CONTACTS

HEADQUARTERS

R&D CENTER

MANUFACTURING CENTER

SALES/SERVICE OFFICE

Camarillo, CA

Phoenix, AZ

Ontario

Andover, MAItaly

Spain

UK

Dubai

Germany

France

Beijing

Shenzhen

Hong Kong

Japan

Singapore

Australia

Page 199: Renewable Energy Solutios

199CONTACTS

HEADQUARTERS

R&D CENTER

MANUFACTURING CENTER

SALES/SERVICE OFFICE

Camarillo, CA

Phoenix, AZ

Ontario

Andover, MAItaly

Spain

UK

Dubai

Germany

France

Beijing

Shenzhen

Hong Kong

Japan

Singapore

Australia

CONTACTS DETAILSGLOBAL

Power-One Renewable Energy Worldwide Sales Offi ces

Country Name/Region Telephone Email

Australia Asia Pacifi c +61 2 9735 3111 [email protected] Asia Pacifi c +86 755 2988 5888 ext.5588 [email protected] Asia Pacifi c +65 6896 3363 [email protected]

France Europe 00 800 00287672 Choix n°4 [email protected] Europe +49 7641 955 2020 [email protected] Europe +39 055 9195 396 [email protected] Europe +34 629253564 [email protected] Kingdom Europe +44 1903 823 323 [email protected]

Dubai Middle East +971 50 100 4142 [email protected]

Canada North America +1 877 261-1374 [email protected] East North America +1 877 261-1374 [email protected] Central North America +1 877 261-1374 [email protected] West North America +1 877 261-1374 [email protected]

Page 200: Renewable Energy Solutios

CONTACTS DETAILSREGIONAL

200 CONTACTS

Power-OneRenewable Energy Worldwide Sales Offices

Country Name/Region Telephone Email

Australia Asia Pacifi c +61 2 9735 3111 [email protected] Asia Pacifi c +65 6896 3363 [email protected] Asia Pacifi c +65 6896 3363 [email protected] Asia Pacifi c +65 6896 3363 [email protected] Asia Pacifi c +86 755 2988 5888 [email protected] Asia Pacifi c +65 6896 3363 [email protected] Asia Pacifi c +65 6896 3363 [email protected] Zealand Asia Pacifi c +61 2 9735 3111 [email protected] Asia Pacifi c +65 6896 3363 [email protected] Asia Pacifi c +65 6896 3363 [email protected] Asia Pacifi c +65 6896 3363 [email protected] Asia Pacifi c +65 6896 3363 [email protected] Asia Pacifi c +65 6896 3363 [email protected]

Austria Europe +49 7641 955 2020 [email protected] Europe +32 3 2560845 [email protected] Europe +421 915755670 [email protected] Republic Europe +421 915755670 [email protected] Europe +49 7641 955 2020 [email protected] Europe +49 7641 955 2020 [email protected] Europe +44 1903 823 323 sales.fi [email protected] Europe 00 800 00287672 Choix n°4 [email protected] Europe +49 7641 955 2020 [email protected] Europe +39 055 9195 439 [email protected] Europe +421 915755670 [email protected] Europe +44 1903 823 323 [email protected] Europe +39 055 9195 396 [email protected] Europe +49 7641 955 2020 [email protected] Europe +49 7641 955 2020 [email protected] Europe +32 3 2560845 [email protected] Europe +44 1903 823 323 [email protected] Europe +421 915755670 [email protected] Europe +34 629253564 [email protected] Europe +421 915755670 [email protected] Europe +421 915755670 [email protected] Europe +421 915755670 [email protected] Europe +34 629253564 [email protected] Europe +44 1903 823 323 [email protected] Europe +49 7641 955 2020 [email protected] Europe +39 055 9195 441 [email protected] Kingdom Europe +44 1903 823 323 [email protected]

Dubai Middle East +971 50 100 4142 [email protected] Middle East +44 1903 823 323 [email protected]

North Africa Africa +971 50 100 4142 [email protected] Africa Africa +39 055 9195 440 [email protected] Africa Africa +39 055 9195 440 [email protected]

Canada North America +1 877 261-1374 [email protected] East North America +1 877 261-1374 [email protected] Central North America +1 877 261-1374 [email protected] West North America +1 877 261-1374 [email protected] Central America +1 877 261-1374 [email protected] & South America Central & South America +1 877 261-1374 [email protected]

Page 201: Renewable Energy Solutios

CONTACTS DETAILSSERVICE

SERVICE

Technical Questions, Returns and Repairs

While Power-One has one of the lowest failure rates in the industry, it is still of utmost importance that when we do have a issue or technical question that we do everything possible to correct it in the most expedited manner.

Talk to a Human

We all know how frustrating it is to deal with a robotic computerized answering system. Power-One is committed to treating you like a real person by staffing our customer information centers with real local people.

If you have a question, you can pick up the phone, email, or use our web portal. We promise to get back to you and help you on your way to solving even the toughest problems.

Toll-Free Telephone Contacts

Australia Aurora® Power Service Asia Pacifi c +61 2 9735 3111China Aurora® Power Service Asia Pacifi c +86 755 2988 5888Singapore Aurora® Power Service Asia Pacifi c +65 6896 3363

France Aurora® Power Service Europe 00 800 00 28 76 72Germany Aurora® Power Service Europe 0800-2200211Italy Aurora® Power Service Europe 00 800 00 28 76 72Spain Aurora® Power Service Europe 00 800 00 28 76 72Switzerland Aurora® Power Service Europe 044 944 8111UK Aurora® Power Service Europe 0800 023 2341

Israel Aurora® Power Service Middle East 972 74 7844444Middle East Aurora® Power Service Middle East 00 800 00 28 76 72

North America Aurora® Power Service North America 1-877-261-1374

Regional Inventory

Power-One is building the industry’s leading regional repair inventory and testing facilities. With locations in virtually every country we sell in, we can ensure a quick and efficient turnaround time on your Inverter when a repair or replacement is required. Our vast global inventory backed by four global manufacturing locations is rapidly becoming the industry standard.

Repairs

Power-One off ers regional return and repair capability as well as special programs to help you maintain an long term relationship with your customers, including swap stock, fixed rate repairs, out of warranty programs and life cycle management programs. Please feel free to ask your local Power-One representative about details.

201CONTACTS

Page 202: Renewable Energy Solutios

202 INFORMATION

Publication Information

Copyright 2011 Power-One Inc.

Ver. 2011-02.2-EN

All rights reserved

All products are subject to technical improvements without notice

Publisher

Power-One Inc

740 Calle Plano, Camarillo, California 93012-8583, USA

Trademarks

Power-One, Aurora, Aurora Uno, Aurora Trio, Aurora Plus, Aurora Station,

Aurora Vision, Aurora Wind, Aurora Service, Aurora Advantage,

Aurora Assure, Aurora Alliance, Aurora Academy

are registered trademarks of Power-One Inc.

Acknowledgements

Design

Luchi Design - Firenze

Photography

Justin Bailie

Dan Patitucci

Industrial Foto

This brochure has been printed on chlorine free paper.

Page 203: Renewable Energy Solutios
Page 204: Renewable Energy Solutios

www.power-one.com

Aim High with

At Power-one, we aim high so you can too.™