60 Receptacles Looking for quick and easy connection? You can´t miss the MENNEKES TwinCONTACT – a spring terminal in a newly designed receptacle. Remove the insulation, insert the conductors, and you’re done. The contact is safely in place and it is even approved as a connection terminal – undo the conductor, that’s all it takes. Press the red button and remove the conductor – this is our concept of convenient and time-saving handling. The swift connection. MENNEKES TwinCONTACT. Colour-coded terminals for unmistakable connections. Suitable for solid conductors and flexible conductors (with end sleeve for strands, crimped so as to be gas-tight or ultrasonically welded). Cond. cross section: at 16A: 1.5 - 4.0 mm 2 , at 32A: 2.5 - 10.0 mm 2 . Through wiring. Safe and easy. With the new MENNEKES TwinCONTACT, the connection of CEE and/or SCHUKO ® receptacles is easily established. Save time. Panel mounted receptacles with TwinCONTACT technology. For installation in ducts, distributors, control cubicles, ... Video: advantages Video: mounting instructions
16
Embed
Receptacles Product information - Elma · mounted installation boxes. CEE receptacles, 3 pole, 230V can be used instead of receptacles SCHUKO® in 60 mm flush mounted installation
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
60 61
Rece
ptac
les
Receptacles K Product information
Looking for quick and easy connection? You can´t miss the MENNEKES TwinCONTACT – a spring terminal in a newly designed receptacle. Remove the insulation, insert the conductors, and you’re done. The contact is safely in place and it is even approved as a connection terminal – undo the conductor, that’s all it takes. Press the red button and remove the conductor – this is our concept of convenient and time-saving handling.
The swift connection. MENNEKES TwinCONTACT.
Colour-coded terminals for unmistakable connections.
Suitable for solid conductors and flexible conductors (with end sleeve for strands, crimped so as to be gas-tight or ultrasonically welded).Cond. cross section:at 16A: 1.5 - 4.0 mm2,at 32A: 2.5 - 10.0 mm2.
Through wiring.Safe and easy. With the new MENNEKESTwinCONTACT, the connection of CEE and/or SCHUKO® receptacles is easily established.
Save time.Panel mounted receptacles with TwinCONTACT technology. For installation in ducts, distributors, control cubicles, ...
Video: advantages
Video: mounting instructions
60 61
Rece
ptac
les
Receptacles K Product information
Use in corrosive environments and under harsh conditions.
Plugs and sockets of AMELAN® with high resistance to chemicals.
Receptacles with auxiliary switch.For additional functions such as control, monitoring, signalling, electrical interlocking etc., an optional auxiliary switch may be installed.
Safety first. There‘s nothing tighter than that. Twisting-proof flange with integral positioned seal.
Highly heat resistant contact carrier. Nickel plated contacts. 16A up to 125A.These appliances are guaranteed to be resistant to corrosive environments: High humidity, salt or acidic air, corrosive gases and vapours. Accordingly, they are mainly used in the food processing industry, in breweries, dairies, farms and market gardens, wineries.
AMELAN® is the plastic used by MENNEKES for plugs and receptacles destined for use in environments where they are exposed to certain chemicals or other corrosive substances. AMELAN® has excellent resistance to fuels, oils and fats, dilute acids and alkalines, cleaning fluids, most aqueous salt solutions and a wide variety of chemicals including aliphatic hydrocarbons. AMELAN® is a plastic that combines high mechanical, thermal and electrical properties with excellent dimensional stability and resistance to chemicals. They are fit for action in chemical plants, in refineries, in the food processing industry, in washdown areas and so on.
AMELAN® is resistant to:K sea waterK detergentsK trichlorethyleneK tolueneK edible fatK aqueous soap solutionK caustic sodaK motor oilsK milkK caustic potashK washing up liquid
K fruit juicesK diesel oilK gasolineK aqueous ammonia solution
62 63
Rece
ptac
les
Receptacles Receptacles K Product information
Cepex receptacles. Perfect in every detail. One fits another.
Cepex receptacles may be used universally. 16A, 3 pole, 230V · 16A, 5 pole, 400V · 32A, 5 pole, 400V. All complete with flush mounted installation box.
An ideal combination: Cepex receptacles 16A, 3 to 5 pole,can be installed in cavity wall or concrete installation boxes(made by Kaiser) with a fixing dimension of 67 mm.
Anything goes.Covers, current rating and colours may be optionallycombined: neutral cover, with labelling field, withlabelling field and lock, 3 pole, 5 pole and SCHUKO®.
In silver, alpine white, pearl white and grey, the Cepexrange matches common colours of various ducts andinstallation devices.
A universal concept. Part no. 41404.The modular Cepex system for flush mounted receptacles.Further versions you can create using Cepex panel mounted receptacles, shown above, in combination with the installation box 41404.
Example: Cepex panel mounted receptacle 16A, 5 pole, 400V with labelling field Part no. 4145 + Flush mounted installation box Part no. 41404 = Flush mounted receptacle
Receptacles SCHUKO® in the Cepex Design. See chapter grounding-type plugs and sockets.
Resistant to ball rebound.All Cepex receptacles with neutral covers meet DIN 18032standards for ball rebound and are suitable for use in sportsfacilities and comparable environments.
62 63
Rece
ptac
les
Receptacles Receptacles K Product information
Cepex wall mounted receptacles.Generous wiring space for supply cable up to 6 mm2. Back box can be rotated by 180°, thus cable insertion is possible from bottom without additional work. Protection type IP 44 (solid body larger and splash waterproof) for versatile conception.
Fitting the new on the old is no problem.Cepex is flexible. Existing installations can be easilyretrofitted. For example to replace Perilex in 70 mm flushmounted installation boxes. CEE receptacles, 3 pole, 230Vcan be used instead of receptacles SCHUKO® in 60 mmflush mounted installation boxes.
A frequently chosen receptacle combination: 16A CEE and16A SCHUKO®. When used with only one supply cable, a3 pole MCB is essential.
Cepex data port receptacles and fibre optics technologyin Cepex receptacles. See chapter special plugs and sockets.
66 67
Rece
ptac
les
Image Title Description
to DIN VDE 0623, EN 60309-2. Colour: electric grey and/or colour code. Enclosure and insert made of AMAPLAST.
Receptacles K Wall mounted receptacles, screw terminals, 16A - 125A,
Wall mounted receptacle
IP 44
Std. Pack. Qty: 5
Product group 1041.Image 1145A.
K screw terminalsK SoftCONTACTK suitable for through wiringK internal fixingK one cable entry at top and two blind cable entries (can be cut
out) at bottomK enclosure base can be turned 180°K with 6 fixing points to accommodate special terminalsK products with pilot contact: part no. + index P
Wall mounted receptacle
IP 67
Std. Pack. Qty: 5
Product group 1049.Image 136A.
K screw terminalsK SoftCONTACTK internal fixingK one cable entry at top and two blind cable entries (can be cut
out) at bottomK enclosure base can be turned 180°K with 6 fixing points to accommodate special terminalsK products with pilot contact: part no. + index P
Wall mounted receptacle
IP 44
Std. Pack. Qty: 10
Product group 1037.Image 1.
K screw terminalsK external fixingK cable entry at top
Wall mounted receptacle
IP 44
Std. Pack. Qty: 10
Product group 1041.Image 1419.
K screw terminalsK internal fixingK one cable entry at top and two blind cable entries (can be cut
out) at bottomK enclosure base can be turned 180°K receptacles are designed for adding an auxiliary contact
switch
Wall mounted receptacle
IP 67
Std. Pack. Qty: 10
Product group 1049.Image 9301.
K screw terminalsK two external fixing holesK one cable entry at top and two blind cable entries (can be cut
out) at bottomK receptacles are designed for adding an auxiliary contact
switchK enclosure base can be turned 180°
66 67
Rece
ptac
les
IP 44 and IP 67 Other voltages and frequencies available on request.
Drawing Amp. 631 MB 213 Poles 3 4 5Dim. in mm a 170 170 170
b 118 118 118c 164 164 164d 134,5 134,5 134,5e 103 103 103f 6,1 6,1 6,1g. 6 6 6h 216 216 216M 40 40 40M* 2xM40 (blind) to be cut out
to DIN VDE 0623, EN 60309-2. Colour: electric grey and/or colour code. Enclosure and insert made of AMAPLAST.
Receptacles K Wall mounted receptacles, screw terminals, 16A - 125A,
Wall mounted receptacle
IP 67
Std. Pack. Qty: 4
Product group 1052.Image 5516.
K screw terminalsK for through wiringK with fixing points for terminal strip part no. 40113
Wall mounted receptacle
IP 67
Std. Pack. Qty: 3
Product group 1052.Image 5519A.
K screw terminalsK SoftCONTACTK for through wiringK with fixing points for terminal strip part no. 40114 or 40115K products with pilot contact: part no. + index P
Wall mounted receptacle
IP 67
Std. Pack. Qty: 1
Product group 1051.Image 2162A.
K screw terminalsK TorsionSpringCONTACTK with large space for accommodating wiringK products with pilot contact: part no. + index P
Image Title Description
Wall mounted receptacle
IP 67
Std. Pack. Qty: 3
Product group 1050.Image 143.
K screw terminalsK products with pilot contact: part no. + index P
68 69
Rece
ptac
les
IP 67 Other voltages and frequencies available on request.
to DIN VDE 0623, EN 60309-2. Colour: grey (RAL 7035). Enclosure and insert made of AMAPLAST.
Receptacles K Cepex wall mounted receptacles, screw terminals,
Cepex wall mounted receptacle, grey
IP 44
Std. Pack. Qty: 5
Product group 1025.Image 4105.
K screw terminalsK cable entry: 1 x M 25 with cable gland at top, 1 x M 25 to be
cut out at the bottom, 1 x M 20 to be cut out at the back side, for cables 7 up to 13 mm Ø
K meeting DIN 18032 standards for ball rebound
Cepex wall mounted receptacle, grey
IP 44
Std. Pack. Qty: 5
Product group 1025.Image 4135.
K screw terminalsK with labelling fieldK cable entry: 1 x M 25 with cable gland at top, 1 x M 25 to be
cut out at the bottom, 1 x M 20 to be cut out at the back side, for cables 7 up to 13 mm Ø
Cepex wall mounted receptacle, grey
IP 44
Std. Pack. Qty: 5
Product group 1025.Image 4165.
K screw terminalsK with labelling fieldK with safety lock, two keysK cannot be dismantled when lockedK on request with identical locksK cable entry: 1 x M 25 with cable gland at top, 1 x M 25 to be
cut out at the bottom, 1 x M 20 to be cut out at the back side, for cables 7 up to 13 mm Ø
K with identical lock: part no. + index G
Cepex double receptacle, grey
IP 44
Std. Pack. Qty: 5
Product group 1027.Image 4202.
screw terminalscable entry: 1 x M 20 plugged at top, 2 x M 25 to be cut out at the bottom, 2 x M 20 to be cut out at the back side, for cables 7 up to 13 mm Ø
K
K
70 71
Rece
ptac
les
16A - 32A, IP 44 Other voltages and frequencies available on request.
Drawing Amp. 16 321 MB 312 Poles 3 4 5 3 4 5Dim. in mm a 93 93 93 93 93 93
Drawing Amp. 161 MB 350 Poles 3 4 5Dim. in mmTerminal for cond. cross 1,5 1,5 1,5section (mm2) min.-max. —4 —4 —4
72 73
Rece
ptac
les
Image Title Description
to DIN VDE 0623, EN 60309-2. Colour: electric grey and/or colour code. Enclosure and insert made of AMAPLAST.
Receptacles K Wall mounted receptacles, screw terminals, highly heat
Wall mounted receptacle
IP 44
Std. Pack. Qty: 10
Product group 1040/1041.Image 20235A.
K screw terminalsK highly heat resistant contact carrierK nickel plated contactsK internal fixingK one cable entry at top and two blind cable entries (can be cut
out) at bottomK enclosure base can be turned 180°
Wall mounted receptacle
IP 44
Std. Pack. Qty: 5
Product group 1041.Image 21253A.
K screw terminalsK highly heat resistant contact carrierK nickel plated contactsK internal fixingK one cable entry at top and two blind cable entries (can be cut
out) at bottomK enclosure base can be turned 180°K products with pilot contact: part no. + index P
Wall mounted receptacle
IP 67
Std. Pack. Qty: 5/3
Product group 1049/1050.Image 21361A.
K screw terminalsK 63A: SoftCONTACTK highly heat resistant contact carrierK nickel plated contactsK products with pilot contact: part no. + index P
Wall mounted receptacle
IP 67
Std. Pack. Qty: 10
Product group 1049.Image 9520.
K screw terminalsK highly heat resistant contact carrierK nickel plated contactsK two external fixing pointsK one cable entry at top and two blind cable entries (can be cut
out) at bottomK enclosure base can be turned 180°
72 73
Rece
ptac
les
resistant contact carrier, nickel plated contacts, 16A - 125A, IP 44 and IP 67 Other voltages and frequencies available on request.
1 MB 209 Amp. 16 321 MB 43 Poles 3 4 5 3 4 5Dim. in mm a 87 128 128 128 128 128
b 64 84 84 84 84 84c 99 122 124 136 136 138d 40 11 11 11 11 11e 50 68 68 68 68 68f 4,5 5,3 5,3 5,3 5,3 5,3g. 4 4 4 4 4 4h 115 144 145 158 158 160M 20 25 25 32 32 32M* M 20 2xM25 (blind) to be cut out 2xM25 (blind) to be cut out
to DIN VDE 0623, EN 60309-2. Colour: grey (RAL 7000) and colour code. Enclosure made of AMELAN®.
Receptacles K Wall mounted receptacles, screw terminals, highly
Wall mounted receptacle
IP 67
Std. Pack. Qty: 5
Product group 1049.Image 3773.
K screw terminalsK SoftCONTACTK highly resistant to chemicalsK highly heat resistant contact carrier, nickel plated contactsK internal fixingK one cable entry at top and two blind cable entries (can be cut
out) at bottomK enclosure base can be turned 180°K 6 fixing points to accommodate special terminals
74 75
Rece
ptac
les
resistant to chemicals, made of AMELAN®, 16A - 63A, IP 67 Other voltages and frequencies available on request.
Drawing Amp. 631 MB 112 Poles 3 4 5Dim. in mm a 170 170 170
b 118 118 118c 175 175 175d 134,5 134,5 134,5e 103 103 103f 6,1 6,1 6,1g. 6 6 6h 219 219 219M 40 40 40M* 2x40 (blind) to be cut out