    Supervisory Control And Data Acquisition System.

    SCADA is the combination of two words:

    Supervisory control

    Data acquisition

  • 7/30/2019 Rahul and Rajan

    3/18

    FREQUENCY CONTROL

    VOLTAGE CONTROL

    LINE LOADING

  • 7/30/2019 Rahul and Rajan

    4/18

    To ensure the maintenance of gridfrequency within the normal band i.e. 49.0to 50.5 Hz, following steps are taken intoaccount:

    Sudden reduction in generator outputparticularly when frequency is falling below49.0 Hz

    Sudden increase in load when frequency isfalling below 49.0 Hz.

  • 7/30/2019 Rahul and Rajan

    5/18

    The operating range of the voltage atvarious voltage levels of grid are asfollows:

    Voltage in KV (RMS)

    Nominal Maximum Minimum

    400 420 360

    220 245 200

    132 145 120

  • 7/30/2019 Rahul and Rajan

    6/18

    In the event of high voltage the following specificsteps would be taken:

    The bus reactors be switched in

    The manually switchable capacitor banks betaken out

    The switchable line/ tertiary reactors be taken in

    Operate synchronous condensers for VARabsorption

    Operate hydro generators / gas turbines assynchronous condenser for VAR absorptionwherever possible

  • 7/30/2019 Rahul and Rajan

    7/18

    In the event of low voltage the following specificsteps would be taken:

    The bus reactors be switched out

    The capacitor banks be switched inThe switchable line / tertiary reactors be

    taken out

    Operate synchronous condensers for VAR

    generation Operate hydro generators / gas turbines as

    synchronous condenser for VAR generation,wherever possible

  • 7/30/2019 Rahul and Rajan

    8/18

    Transducers

    Potential and Current Transformers

    Remote Terminal Unit (RTU) MODEM

    Power Line Carrier Communication(PLCC)

    Front End Processor

    LAN

    Main Server

  • 7/30/2019 Rahul and Rajan

    9/18

    MODEM

    MODEMCFEHUBCOMPUTERS

    SERVERS

    CTS/PTS

    TRANS-DUCER RTU

  • 7/30/2019 Rahul and Rajan

    10/18

    Typical RTU has a network interface (usually eitherEthernet, proprietary, or both), a simple processor,some environmental sensors, some override

    switches, and a bus, which it uses to communicatewith devices and/or interface, boards.

    There are two modes in which RTUs work:

    1) Under command from central computer

    2) Stand alone mode

  • 7/30/2019 Rahul and Rajan

    11/18

    RTU

  • 7/30/2019 Rahul and Rajan

    12/18

    BASIC FUNCTIONS OF RTU

    Collect power system data

    Filter and process the system data

    Transmit data to control center

    Receive the control commands

  • 7/30/2019 Rahul and Rajan

    13/18

    There are two types of displays:

    Online Display

    In a one line or single line display wholenetwork is made up of single lines andgraphical symbol are used for differentcomponents.

    One-line diagrams give the current state of the

    operating devices and also give on line data.We can give command from one line diagramto control the state of the devices and canchange the way of displaying the data.

  • 7/30/2019 Rahul and Rajan

    14/18

  • 7/30/2019 Rahul and Rajan

    15/18

    Tabular display also gives the state of theoperating devices and current data.

    But in this case information is in thetabular form i.e. in the form of rows andcolumns.

    Tabular usually contains moreinformation the one line displays.

  • 7/30/2019 Rahul and Rajan

    16/18

  • 7/30/2019 Rahul and Rajan

    17/18

    Increase Efficiency

    Minimize Fault Response Time Reduce Planned Downtimes

    Maximize Profitability

    Reduce Manpower Requirement Maximize Safety

  • 7/30/2019 Rahul and Rajan