Top Banner
Document ID: sv_saia_burgess_controls_en_v17_05 https://sevio.it Quick user guide to use Sevio with Saia PCD ® control system - Saia Burgess Controls
11

Quick user guide to use Sevio with Saia PCD control system ... · Document ID: sv_saia_burgess_controls_en_v17_05 6 1 Use of Sevio system Each Sevio Router is distinguished by a specific

Aug 15, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Quick user guide to use Sevio with Saia PCD control system ... · Document ID: sv_saia_burgess_controls_en_v17_05 6 1 Use of Sevio system Each Sevio Router is distinguished by a specific

Document ID: sv_saia_burgess_controls_en_v17_05 https://sevio.it

Quick user guide to use Sevio

with Saia PCD®

control system - Saia Burgess Controls

Page 2: Quick user guide to use Sevio with Saia PCD control system ... · Document ID: sv_saia_burgess_controls_en_v17_05 6 1 Use of Sevio system Each Sevio Router is distinguished by a specific

Document ID: sv_saia_burgess_controls_en_v17_05

https://sevio.it 2

© 2017 Sevio. All rights reserved.

Trademarks

Sevio is a Sevio S.r.l. trademark. Saia Burgess Controls, PG5, SBC are Saia-Burgess Controls AG

registered brand. Other product names and brands are registered brands or trademarks of their respective

owners.

Declaration of terms

In the interest of improving internal design and operational aspects, Sevio S.r.l. reserves the right to make

changes to the products described herein without any prior warning.

Sevio S.r.l. disclaimes any liability for the application of the products or circuit diagrams described herein.

Page 3: Quick user guide to use Sevio with Saia PCD control system ... · Document ID: sv_saia_burgess_controls_en_v17_05 6 1 Use of Sevio system Each Sevio Router is distinguished by a specific

Document ID: sv_saia_burgess_controls_en_v17_05

https://sevio.it 3

Preface

Industrial production demands in the era of globalization or delocalization are becoming increasingly more

complex. Within this context, creating a network of systems, processes and information is critical in order

to ensure success in a perpetually competitive environment and guarantee a continuous presence. Thus,

the possibility to remotely manage a production system becomes a keystone allowing reduced processing

times and costs, subsequently increasing and enhancing the performance of your business. Our objective

is to offer a system that complements existing computer technology, offering Clients simple, efficient and

secure control solutions.

The aims of the Sevio system are:

to offer Clients a private, affordable and continuously available network;

to relieve Clients of the need to perform complex configurations and subsequent maintenance;

to guarantee the highest standards of security;

to offer an efficient and timely system during all stages of a project's development.

The Sevio solution does not require the installation of any particular software or supplementary hardware.

Through the Sevio Portal, a Web application accessible from https://sevio.it/, parameters can be edited

remotely, system statuses can be viewed, and much more still.

So at this point, happy working!

Sevio S.r.l.

Page 4: Quick user guide to use Sevio with Saia PCD control system ... · Document ID: sv_saia_burgess_controls_en_v17_05 6 1 Use of Sevio system Each Sevio Router is distinguished by a specific

Document ID: sv_saia_burgess_controls_en_v17_05

https://sevio.it 4

The Sevio system has been designed to offer Clients a solution for the connection of multiple independent

and physically dislocated networks, transforming them into numerous Sevio networks. Each Client is the

owner of a Realm which is the set of all Sevio networks and Control Stations (PC, tablet, smartphone).

This document explains how to use the Sevio system combined with Saia Burgess Controls products.

Index

Requirements ................................................................................................................................................... 5

1 Use of Sevio system ............................................................................................................................. 6

2 Sevio and Saia Burgess Controls ........................................................................................................ 7

2.1 Preliminary configuration ............................................................................................................... 8

2.2 Remote access.............................................................................................................................. 9

3 Declaration of conformity and warranty ........................................................................................... 11

For Sevio system functions and characteristics refer to the Sevio User Guide.

Page 5: Quick user guide to use Sevio with Saia PCD control system ... · Document ID: sv_saia_burgess_controls_en_v17_05 6 1 Use of Sevio system Each Sevio Router is distinguished by a specific

Document ID: sv_saia_burgess_controls_en_v17_05

https://sevio.it 5

Requirements

The fundamental requirements for use of the Sevio system with Saia Burgess Controls products are:

the Sevio Router;

the Registration Sheet (supplied along with the Sevio Router);

a Saia Burgess Controls PLC or HMI with Ethernet connectivity;

a PC with up-to-date web browser and Saia PG5 software installed;

an Internet access.

Page 6: Quick user guide to use Sevio with Saia PCD control system ... · Document ID: sv_saia_burgess_controls_en_v17_05 6 1 Use of Sevio system Each Sevio Router is distinguished by a specific

Document ID: sv_saia_burgess_controls_en_v17_05

https://sevio.it 6

1 Use of Sevio system

Each Sevio Router is distinguished by a specific Sevio network. In the example above, the Sevio network

of plant A is 10.254.12.x, while the Sevio network of plant B is 10.128.71.x.

To access the PLC of plant A from the Control Station, it’s sufficient to combine the first three bytes of the

specific Sevio network with the fourth byte of the PLC address:

Control Station

10.254.12.30

Plant A

IP: 192.168.1.30

IP: 192.168.1.31

IP: 192.168.1.1

Sevio Network

10.254.12.x

Plant B

IP: 192.168.1.30

IP: 192.168.1.31

IP: 192.168.1.1

Sevio Network

10.128.71.x

Sevio Network plant A…...….

virtual:

PLC address plant A…...….

Remote PLC address plant A…...….

10 . 254 . 12 . x

10 . 254 . 12 . 30

192 . 168 . 1 . 30

Page 7: Quick user guide to use Sevio with Saia PCD control system ... · Document ID: sv_saia_burgess_controls_en_v17_05 6 1 Use of Sevio system Each Sevio Router is distinguished by a specific

Document ID: sv_saia_burgess_controls_en_v17_05

https://sevio.it 7

2 Sevio and Saia Burgess Controls

The Sevio system allows Control Stations to communicate with all devices connected to the various Sevio

Routers.

Another exclusive feature of the Sevio system is routing, or rather the possibility for communication

between devices connected to different Sevio networks, yet forming part of the same Realm.

To use the routing feature, it is required to configure the Sevio Router as the default Gateway IP address

into all the network devices that communicate with each other.

Plant A

IP: 192.168.0.104 IP: 192.168.0.1

Sevio Network

10.254.12.x

Plant B

IP: 192.168.1.83

IP: 192.168.1.1

Sevio Network

10.128.71.x

Realm

IP LAN….192.168.0.1

IP Address..……192.168.0.104

Subnet Mask….. 255.255.255.0

Gateway………..192.168.0.1

IP Address..……192.168.0.105

Subnet Mask….. 255.255.255.0

Gateway………..192.168.0.1

Page 8: Quick user guide to use Sevio with Saia PCD control system ... · Document ID: sv_saia_burgess_controls_en_v17_05 6 1 Use of Sevio system Each Sevio Router is distinguished by a specific

Document ID: sv_saia_burgess_controls_en_v17_05

https://sevio.it 8

2.1 Preliminary configuration

The procedure below describes the preliminary configuration of devices that need to be accessible

remotely.

A Sevio Router is sometimes installed in existing systems by personnel that is not qualified to modify the

software configuration. Using the Masquerade mode (see chapter Sevio Router Parameters in Sevio User

Guide) it is possible to access devices remotely omitting the procedure below.

NOTE: that enabling masquerade mode prevents the PLC/HMI device from originating connections to the

Sevio Network.

Go to Device Configurator, Ethernet port IP Settings which in the example 192.168.0.104 .

Go to the Sevio Router parameters through the Sevio Portal and assign a /24 IP LAN address (see chapter Sevio Router Parameters in Sevio User Guide).

Insert such address in the Gateway field the Sevio Router LAN IP address assigned, as shown in the example 192.168.0.1.

Enable Ether S-Bus.

In the Ethernet Protocol section, select IP Transfer Protocols, enable three functions as shown in the example.

Page 9: Quick user guide to use Sevio with Saia PCD control system ... · Document ID: sv_saia_burgess_controls_en_v17_05 6 1 Use of Sevio system Each Sevio Router is distinguished by a specific

Document ID: sv_saia_burgess_controls_en_v17_05

https://sevio.it 9

2.2 Remote access

Select device, insert in IP Address or Host Name, select connection setting IP address by NAT (remote TCP).

Digit the remote PLC IP address:

From this moment on, it is possible to perform all activities online.

Virtual IP:…………

Local PLC:……….

Remote PLC:…..….

10 . 255 . 254 . x

10 . 255 . 254 .104

192 . 168 . 0 . 104

Page 10: Quick user guide to use Sevio with Saia PCD control system ... · Document ID: sv_saia_burgess_controls_en_v17_05 6 1 Use of Sevio system Each Sevio Router is distinguished by a specific

Document ID: sv_saia_burgess_controls_en_v17_05

https://sevio.it 10

Select device and go to Device Configurator.

Press Start Download.

From this moment on, it is possible to connect to PLC via webserver.

Page 11: Quick user guide to use Sevio with Saia PCD control system ... · Document ID: sv_saia_burgess_controls_en_v17_05 6 1 Use of Sevio system Each Sevio Router is distinguished by a specific

Document ID: sv_saia_burgess_controls_en_v17_05

https://sevio.it 11

3 Declaration of conformity and warranty

Sevio S.r.l. declares that the Sevio Basic device is compliant with the essential requirements and all

relevant provisions of Directive 1999/5/EC.

Sevio S.r.l. declares that the Sevio One device is compliant with the essential requirements and all

relevant provisions of Directive 2014/30/EU.

Extended Declarations of Conformity may be requested by contacting [email protected].

Every request for replacement under warranty must be sent before the expiry of the 2-year warranty and

must be transmitted together with the product that has allegedly presented an anomaly.

SEVIO

Sevio S.r.l.

Via Dei Caniana, 6/a – Bergamo (IT)

Tel. (+39) 035 0514333

Email customer assistance: [email protected]

Email sales department: [email protected]

https://sevio.it