Top Banner
QLogic FabricCache™ 10000 Séries Adapter 2-7-13v1
27

QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

Jun 10, 2015

Download

Technology

QLogic FabricCache VDI installation 1200 seats CrossIT - ACNC/JetStor profile
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

QLogic FabricCache™ 10000 Séries Adapter

2-7-13v1

Page 2: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

• Fibre Channel Adapters• Multiprotocol Storage Controllers• Enterprise Application Acceleration (Cache Optimized SAN)• 10/40/100Gb Ethernet and Converged Networking

QLogic Company Highlights

2

• ~1,100 employees worldwide• Development centers in U.S. and India• Manufacturing (CM) in China and Malaysia• Fulfillment centers in U.S., Asia, and Europe

Growing global presence

• Over 15 million FC Adapter Ports Shipped• Most Established, Proven, Pervasive Storage Stack in the Industry• Strong IP, Expertise in Storage Networking• Growing Market Opportunities in Enterprise Application Acceleration

Significant Competitive Advantages

Leader in Key Market Sectors

58%

22%

11% 9%

Engineers Sales G&A Operations

Page 3: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

New Acquisitions

3

• Brocade Fibre Channel and Converged Network Adapters• 8Gb FC• 10GbE FCoE• 16Gb & 10GbE Fabric Adapter

• Broadcom NetXtreme II• 10GbE family• 40GbE currently under design reviews with all major server OEMs• 100GbE on roadmap

Page 4: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

QLogic “New” BR Adapters Product Summary

4

QLogic815/825HBA

QLogic1020CNA

• 8/4/2 Gbps FC• Single and dual port• 1600 MB/s, 500K IOPS/port• 1st Generation ASIC (Crossbow)

• 10 Gbps CEE for IP and FCoE• Dual port• Copper (active twinax) and optical• 2nd Generation ASIC (Catapult-1 aka Cat-1)

QLogic OEMMezzanine

• Brocade 1007: IBM CNA• Brocade 1741M: Dell CNA• Brocade 1867: IBM 2-port Fabric Adapter• Brocade 1869: IBM 4-port Fabric Adapter

QLogic1860Fabric Adapter

• 16/8/4/2 Gbps FC, 10GbE & FCoE• AnyIO™ single and dual port• 3200 MB/s, 500K IOPS/port• 3rd Generation ASIC (Catapult-2 aka Cat-2)

Page 5: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

Broadcom HP

5

Page 6: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

Broadcom Dell

6

Page 7: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

Broadcom IBM

7

For additional Information go to:http://go.broadcom.com/IBM

Page 8: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

QLogic Across the Data Center

Fibre Channel Adapter

Ethernet & iSCSI Adapters

Converged Network Adapter

8

Targets

Stackable Switches

iSCSI Array Targets

Fibre Channel Array Targets

Fibre Channel & Converged Blade Switch Modules

Fibre ChannelEthernet & iSCSI

Converged

Adapters & ASICs

Blade Modules

Fibre Channel Switches

Converged Array Targets

Shared Cache

Caching Adapters

FabricCache Adapters

Fibre Channel SAN

Converged Switching Modules

ConvergedEthernet

Page 9: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

Server Based Cache

Accelerates applications

The I/O Performance Gap

9

TIME

PERF

ORM

ANCE

GRO

WTH

AREAL DENSITY SPINDLE SPEED

MODERATE GROWTH

ENORMOUS GROWTH

MORE POWERFUL PROCESSORS

MECHANICAL DRIVES

PROCESSORS

• Performance hungry business critical applications

• Demanding more transactions and less waiting

Applications

• Mechanical HDDs and array controllers can’t keep up

Storage

FLASH MEMORYDEVICES

Page 10: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

Solving the I/O Performance Gap

PROs

• Easy to manage; shared

• Simple to implement

• Improved I/O performance

Array Networks Servers

PROs

• Centralized cache

• Shared cache by all servers

• Can cache network storage

PROs

• Critical data close to applications

• Improved storage performance and utilization

• Offloads Storage Network

Storagecache / tier

Cachingappliance

Servercache

CONs

• Distance from server processor (latency)

• Limitations of storage array controllers

• Potential SAN bottleneck

CONs

• Single point of failure

• Appliances can be expensive

• Potential SAN bottleneck

CONs

• Complexity & dependencies

• Cached data is captive in server “DAS SSD”

• Clusters not supported

Page 11: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

Server-based Caching 1.0

Enterprise Application Acceleration2.0 Unleashes Performance for More Applications & Vast SAN Installed Base

11

• Captive to single server

• Incremental drivers and management

• No cluster support

• Breaks shared data model

• Separate SAN adapter required

Cache as shared SAN resource

Clustered environments

Needed for 2.0

Utilize existing drivers and management framework

Simple/non-disruptive to deploy

Maintain existing SAN architectural rules

Support virtualization (multi-server)

Shared performance acceleration. Simple and seamless integration.

Page 12: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

QLogic FabricCache QLE10000 Adapter

12

Easy, Intuitive Interface Plug-ins for Hypervisor and Management Frameworks

Same Standard HBA Driver

Open API

Powerful Expert

Interface

QLE10522-CQLE10542-C

200GB PCIe400GB PCIePCIe slot for power

8Gb Dual-port FCCaching Engine• DDR memory• 4 Core SOC

Shareable Enterprise SLC flash

SSD HBA Operating System Driver

Plug-Ins

1st in a new generation of

GUI CLI

C:/flush_cache

API

Logically appears as a single standard adapter

Page 13: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

SANCore

SANLUNs

SANCache

QLogic FabricCache QLE10000 Adapter Differentiated Functionality

13

1. Consolidate with a combined Fibre Channel adapter & cache solution

2. Simplify with transparent cache

3. Share cache among clustered servers and applications

Application

HBA Driver

Shared application performance acceleration for the SAN

Page 14: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

Consolidate w/ a Combined Fibre Channel Adapter & Cache SolutionUnique to FabricCache

14

Caching & I/Omanagement Flash & SSDsSAN Adapter

FabricCacheSolution

Unequaled Storage Networking Heritage:

• Field proven protocol stacks

• Over 14 million ports in use

• Trusted tier-1 OEM supplier

Ground Breaking Innovation:

• HBA with cache integration

• Patent-pending SAN-based cache sharing

• Combined with COTS Flash Technology

Anatomy of the FabricCache 10000 Series Adapter

Page 15: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

Simplify with Transparent CacheUnique to FabricCache

15

Application

Filter Driver / Agent

HBA Driver SSD Driver

Application

HBA Driver

1.0 Captive Server-Based SSD - Drivers and management for caching adapter must be installed and managed

2.0 QLE10000 adapter solution - Transparent cache with single, standard driver

Same standard HBA driver. No changes needed. Seamless integration.

Page 16: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

2.0 QLE10000 Adapter Solution

Transparent cache is shared by all servers. All SAN LUNs are available to all servers.

1.0 Captive Server-Based Cache

Cache is DAS captive to one server. Each SAN LUN is captive to one server.

Share Cache Among Clustered Servers and ApplicationsUnique to FabricCache

16

SANCore

SANCore

SANLUNs

SANLUNs

SANCache

DASSSD

Performance Benefits for more applications

Page 17: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

User requirements

• Cluster support is needed

• Node failover with warm cache

• Latency is critical (<1ms)

• Storage management

• Exponential growth in database sizes and active data sets

User requirements

• Support for vMotion maintaining warm cache

• Faster time-to-data means more VMs per server

• Virtualize business-critical applications & workloads

• Weather VDI boot storms

User requirements

• Support for clustering

• Faster response times

• Small block transactions

• Mailbox sizes are growing

• Mobile users drive 4x the requirements

Enterprise Application Requirements: Optimize Time to Data

17

Hypervisor & VDI Database Collaboration

Page 18: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

Oracle RAC Cluster 82% Faster Response Time

18

87% reduction in demand of array (disk IOPs)

57% reduction in average transaction response

82% cut in peak transaction response

2-Node RAC 11gR2 (11.2.0.3)Intel Xeon E7 servers

Dual 6-core processors, 198GB RAMQLE10000 SSD HBA

146GB Pillar Axiom SAN Storage with 15K RPM HDDs1000 Concurrent Users

Frequently accessed Tempdb, Index and Log files cached on

the SAN cache

Less frequently accessed data stored on high-availability SAN LUN

OS

RAC Instance 1

OS

RAC Instance 2

Page 19: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

SANCore

SANLUNs

SANCache

Server Virtualization Cache Stays Warm, Performance Stays High

19

Frequently accessed files cached on a high- performance, SAN cache

Live VM migration without refilling cacheSupports automation such as DRS

OSApp 2

Hypervisor

OS OSApp 1 App 2

Hypervisor

OS OSApp 3 App 4

Less frequently accessed data stored on high-availability SAN LUN

Page 20: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

Demo

Page 21: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

Titusville Area School District

Page 22: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

• Security patches and application updates were difficult to install in every individual device, which put the district at risk from malware.

• The district turned to Cross IT Services & Solutions, LLC, a QLogic Advanced Solutions Partner specializing in virtualization technology and the education market, to help develop and implement a plan.

The Challenge

• The Titusville IT team launched a virtual desktop initiative and realized that architecting a district-wide deployment took more resources than they had in-house.

Page 23: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

The Solution

• Five rack mounted Dell R815 rack servers

• Five QLogic QLE10522 FabricCache adapters – one in each

server

• Two QLogic SB5802 8Gb Fibre Channel stackable switches

• Two JetStor SAS 724iFD 24-bay RAID Arrays, each with four

200GB solid-state drives & twenty 600 GB hard drives, for

25.6TB of storage capacity

• VMware® View 5.2

Page 24: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

The Solution

8Gb Fibre Channel

AC&NC JetStor® SAS 724iFD RAID Arrays - 25.6 TB

QLE10522

QLE10522

QLE10522

QLE10522

QLE10522SB5802v Switches

Page 25: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

SANCore

SANLUNs

SANCache

FabricCache QLE10000 Summary

27

Consolidate with a combined Fibre Channel adapter & cache solution

Simplify with transparent cache

Share cache among clustered servers and applications

No Changes to existing SAN infrastructure, SW drivers or management framework

Enterprise Application Acceleration for single and clustered multi-server virtualized environments

Application

HBA Driver

Page 26: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014

Survey

VMUG 201428

Page 27: QLogic - CrossIT - ACNC/JetStor FibricCache VMUG 2014