1 59TP6A Performance Two-Stage, Variable Speed 4-Way Multipoise Condensing Gas Furnace Series 2, 3 Product Data A11263 The 59TP6A Multipoise Variable−Speed Condensing Gas Furnace features the two−stage Performancet System. The Comfort HeatR technology two−stage gas valve is at the heart of the comfort provided by this furnace, along with the variable−speed ECM blower motor, and two−speed inducer motor. With an Annual Fuel Utilization Efficiency (AFUE) up to 96.5%, the Performancet Series two−stage gas furnace provides exceptional savings when compared to standard gas furnaces. This Performance Gas Furnace also features 4−way multipoise installation flexibility, and is available in eight model sizes. The 59TP6A can be vented for direct vent/two−pipe, ventilated combustion air, or single−pipe applications. All units meet California Air Quality Management District emission requirements. All sizes are design certified in Canada. STANDARD FEATURES S All sizes meet ENERGY STARR Version 4.1 criteria for gas furnaces: 95+AFUE. S Quiet operation. Compare for yourself at HVACpartners.com. S Series 3 or greater (sizes 080−20, 100−20, 120−22) allow 15 Amp breaker with accessory (order separately). S Ideal height 35” (889 mm) cabinet: short enough for taller coils, but still allows enough room for service. S Silicon Nitride Perfect LightHot Surface Igniter. S ComfortFantechnology allows control of continuous fan speed from a compatible thermostat. S 4−way multipoise design for upflow, downflow or horizontal installations, with unique vent elbow and optional through− the−cabinet downflow venting capability. S Full−featured variable−speed blower motor, two−speed inducer motor, and two−stage gas valve. S Self−diagnostics. S Adjustable blower speed for cooling, continuous fan, and dehumidification. S Aluminized−steel primary heat exchanger. S Stainless−steel condensing secondary heat exchanger. S Propane convertible (See Accessory list). S Factory−configured ready for upflow applications. S Fully−insulated casing including blower section. S Convenient Air Purifier and Humidifier connections. S Direct−vent/sealed combustion, single−pipe venting or ventilated combustion air. S Installation flexibility: sidewall or vertical vent. S Residential installations may be eligible for consumer financing through the Retail Credit Program. S Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with ASHRAE standard 193. TM
16
Embed
Product Data - utcccs-cdn.com · 1 59TP6A Performance Two-Stage, Variable Speed 4-Way Multipoise Condensing Gas Furnace Series 2, 3 Product Data A11263 The 59TP6A Multipoise Variable−Speed
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
1
59TP6APerformance Two-Stage, Variable Speed4-Way Multipoise Condensing Gas FurnaceSeries 2, 3
Product Data
A11263
The 59TP6A Multipoise Variable−Speed Condensing Gas Furnacefeatures the two−stage Performance� System. The Comfort Heat�technology two−stage gas valve is at the heart of the comfortprovided by this furnace, along with the variable−speed ECMblower motor, and two−speed inducer motor. With an Annual FuelUtilization Efficiency (AFUE) up to 96.5%, the Performance�Series two−stage gas furnace provides exceptional savings whencompared to standard gas furnaces. This Performance Gas Furnacealso features 4−way multipoise installation flexibility, and isavailable in eight model sizes. The 59TP6A can be vented fordirect vent/two−pipe, ventilated combustion air, or single−pipeapplications. All units meet California Air Quality ManagementDistrict emission requirements. All sizes are design certified inCanada.
STANDARD FEATURES� All sizes meet ENERGY STAR� Version 4.1 criteria for gas
furnaces: 95+AFUE.
� Quiet operation. Compare for yourself at HVACpartners.com.
� Series 3 or greater (sizes 080−20, 100−20, 120−22) allow 15
Amp breaker with accessory (order separately).
� Ideal height 35” (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service.
� Silicon Nitride Perfect Light Hot Surface Igniter.
� ComfortFan technology allows control of continuous fan
speed from a compatible thermostat.
� 4−way multipoise design for upflow, downflow or horizontal
installations, with unique vent elbow and optional through−
�Capacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate.
‡Minimum heat CFM when low-heat rise adjustment switch (SW 1-3) and comfort/efficiency adjustment switch (SW1-4) on control center are OFF.
ESP - External Static Pressure
FEATURES AND BENEFITSComfort Heat Technology� — This feature with AdaptiveControl is a proprietary function that promotes homeownercomfort through two stages of heating. This Carrier furnace offers apatented algorithm that continually monitors and adjusts furnaceoperation by looking at both current and past conditions todetermine the most effective stage of heating and the amount oftime to run each stage, every cycle.SmartEvap� Technology — When paired with a compatiblethermostat, this dehumidification feature overrides the coolingblower off-delay when there is a call for dehumidification. Bydeactivating the blower off-delay, SmartEvap technology preventscondensate that remains on the coil after a dehumidification cyclefrom re-humidifying throughout the home. This results in reducedhumidity and a more comfortable indoor environment for thehomeowner.Unlike competitive systems, SmartEvap technology only overridesthe cooling blower off delay when humidity control is needed.Once humidity is back in control, SmartEvap re-enables theenergy-saving cooling blower off-delay.ComfortFan� Technology — Sometimes the constant fan settingon a standard furnace system can actually reduce homeownercomfort by providing too much or too little air! Fan On Plustechnology improves comfort all year long by allowing thehomeowner to select the continuous fan speed of their choice usinga compatible thermostat.
HYBRID HEAT� Dual Fuel system — This system can providemore control over your monthly energy bills by automaticallyselecting the most economical method of heating. With HYBRIDHEAT, our system automatically switches between the gas furnaceand the electric heat pump as outside temperatures change tomaintain greater efficiency and comfort than with any traditionalsingle-source heating system. The heat pump also delivershigh-efficiency cooling in the summer.
Power Heat� Igniter — Carrier’s unique SiN igniter is not onlyphysically robust but it is also electrically robust. It is capable ofrunning at line voltage and does not require complex voltageregulators as do other brands. This unique feature further enhancesthe gas furnace reliability and continues Carrier’s tradition oftechnology leadership and innovation in providing a reliable anddurable product.
Full-Featured, Variable Speed Motors — Our variable−speedECM (Electronically Commutated Motor) optimizes comfort levelsin the home year round; features such as passive/activedehumidification, ramping profiles, and quiet operation. They canprovide cooling match enhancements to increase the effectiveSEER of select Carrier air conditioner or heat pump system. Thismotor does not report back RPM and static pressure to the furnacecontrol.Reliable Heat Exchanger Design — The aluminized steel, clamshell primary heat exchanger was re−engineered to achieve greater
efficiency out of a smaller size. The first two passes of the heatexchanger are based on the current 80% product, a design withmore than ten years of field-proven performance and success.These innovations, paired with the continuation of a crimped,no-weld seam create an efficient, robust design for this essentialcomponent.
The condensing heat exchanger, a stainless steel fin and tubedesign, is positioned in the furnace to extract additional heat.Stainless steel coupling box componentry between heat exchangershas exceptional corrosion resistance in both natural gas andpropane applications.
Optional Media Filter Cabinet — Enhanced indoor air quality inthe home is made easier with our media filter cabinet Wheninstalled as a part of the system, this cabinet allows for easy andconvenient addition of a Carrier high efficiency air filter.4-Way Multipoise Design — One model for all applications –there is no need to stock special downflow or horizontal modelswhen one unit will do it all. The new heat exchanger design allowsthese units to achieve the certified AFUE in all positions.Direct or Single-pipe Venting, or Optional VentilatedCombustion Air — This furnace can be installed as a 2-pipe(Direct Vent) furnace, in an optional ventilated combustion airapplication, or in single-pipe, non-direct vent applications. Thisprovides added flexibility to meet diverse installation needs.Sealed Combustion System — This furnace brings in combustionair from outside the furnace, which results in especially quietoperation. By sealing the entire combustion vestibule, the entirefurnace can be made quieter, not just the burners.
Insulated Casing — Foil-faced insulation in heat exchangersection of the casing minimizes heat loss. The acoustical insulationin the blower compartment reduces air and motor noise for quietoperation.Monoport Burners — The burners are specially designed andfinely tuned for smooth, quiet combustion and economicaloperation.
Bottom Closure — Factory−installed for side return; easilyremovable for bottom return. The multi-use bottom closure canalso serve for roll-out protection in horizontal applications, and actas the bottom closure for the optional return air base accessory.Certifications — This furnace is CSA (AGA and CGA) designcertified for use with natural and propane gases. The furnace isfactory−shipped for use with natural gas. A CSA listed gasconversion kit is required to convert furnace for use with propanegas. The efficiency is AHRI efficiency rating certified. This furnacemeets California Air Quality Management District emissionrequirements.
59T
P6A
3
MODEL NUMBER NOMENCLATURE
59 T P 6 A 040 E 14 -- -- 10
S - Single StageT - Two StageM - Modulating
C - ComfortP - PerformanceN - Infinity
S - StandardE - Energy EfficientV - Variable Speed
REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.
ELECTRICAL JUNCTIONBOX (IF REQUIRED, LOCATION MAY VARY)
MEDIA CABINET
OPERATING INSTRUCTIONSNOT SHOWN (LOCATED ONMAIN FURNACE DOOR, SEE OPERATING INSTRUCTIONS INSIDE DOOR FIGURE).
FURNACECONTROLBOARD
MANUAL RESETROLLOUT SWITCH
FLAMESENSOR
MANUAL RESETROLLOUT SWITCH
GAS BURNER
HOT SURFACEIGNITER
INDUCER MOTORASSEMBLY
BLOWER ANDMOTOR
CAPACITOR/POWER CHOKE(IF USED)
BLOWER DOORSAFETY SWITCH
A170154
59T
P6A
4
SPECIFICATIONSThe furnace should be sized to provide 100 percent of the designheating load requirement plus any margin that occurs because offurnace model size capacity increments. None of the furnacemodel sizes can be used if the heating load is 20,000 BTU orlower. Use Air Conditioning Contractors of America (Manual Jand S); American Society of Heating, Refrigerating, andAir-Conditioning Engineers; or other approved engineering
method to calculate heating load estimates and select the furnace.Excessive oversizing of the furnace may cause the furnace and/orvent to fail prematurely, customer discomfort and/or vent freezing.
Failure to follow these guidelines is considered faulty installationand/or misapplication of the furnace; and resulting failure, damage,or repairs may impact warranty coverage.
Accessory Connections EAC (115vac); HUM (24vac); 1stg AC (via Y/Y2)
* See Accessory List for part numbers available.� Low Amp Kit (KGAPC0101ECM) allows select furnaces to be installed with a 15 Amp Breaker and 14 AWG wire within the listed wire length.
59T
P6A
5
ACCESSORIESDESCRIPTION PART NUMBER 040-10 040-12 060-12 060-14 080-16 080-20 100-20 120-22
Venting Accessories
Vent Kit Through the Cabinet KGADC0101BVC � � � � � � � �
Low Heat Airflow 3 1735 1675 1625 1560 1500 1455 1395 1345 1285 12251. Nominal 350 CFM/ton cooling airflow is delivered with SW1-5 and SW2-2 set to OFF.
Set both SW1-5 and SW2-2 to ON for +7% airflow (nominal 370 CFM/ton). Set SW1-5 to ON and SW2-2 to OFF for +15% airflow (nominal 400 CFM/ton). Set SW2-2 to ON and SW1-5 to OFF for -7% airflow (nominal 325 CFM/ton). The above adjustments in airflow are subject to motor horsepower range/capacity.
2. Maximum cooling airflow is achieved when switches SW2-6, SW2-7, SW2-8 and SW1-5 are set to ON, and SW2-2 is set to OFF.
3. All heating CFM's are when low heat rise adjustment switch (SW1-3) and comfort/efficiency adjustment switch (SW1-4) are both set to OFF.
4. Ductwork must be sized for high-heating CFM within the operational range of ESP. Operation within the blank areas of the chart is not recommended because high-heat operation will be above 1.0 ESP.
5. All airflows of 1880 CFM or less on 21" and 24.5" casing size furnaces are 5% less on side return only installations.
6. Return air above 1800 CFM on 24.5” casing requires two sides, one side and bottom, or bottom only to allow sufficient airflow to the furnace.
7. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return.
8. Airflow not stable at this ESP.
59T
P6A
9
MAXIMUM ALLOWABLE EXPOSED VENT LENGTHTable 1 – Maximum Allowable Exposed Vent Lengths in Unconditioned Space Insulation Table − Ft.
* Pipe length (ft) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowable pipelength calculated from Table 2.
† Insulation thickness based on R value of 3.5 per in.
59T
P6A
10
MAXIMUM EQUIVALENT VENT LENGTH − FT. (M)NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows.
Use Table 3 − Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
1. Inducer Outlet Restrictor disk (P/N 337683-401; 1.25-in. (32 mm) Dia.) shipped in the loose parts bag or available through Replacement Componentsrequired under 10-ft. (3 M) TEVL in all orientations. Required for installations from 0 - 2000 (0 to 610 M) above sea level. Failure to use an outlet restrictor may result in flame disturbances or flame sense lock-out.
2. Inducer Outlet Restrictor disk (P/N 337683-401; 1.25-in. (32 mm) Dia.) available through Replacement Components required for no greater than 5-ft. (1.5M) TEVL in downflow and horizontal orientations only. Required for installations from 0 - 2000 (0 to 610 M) above sea level.
3. Inducer Outlet Restrictor disk (P/N 337683-402; 1.50-in. (38 mm) Dia.) available through Replacement Components required for no greater than 5-ft. (1.5M) TEVL in downflow and horizontal orientations only. Required for installations from 0 - 2000 (0 to 610 M) above sea level.
Long Medium Mitered
Concentric
Standard 2-in., 3-in., or optional 4-in. termination.
ELBOW CONFIGURATIONS VENT TERMINAL CONFIGURATIONS
A13110
Table 3 – Deductions from Maximum Equivalent Vent Length − Ft. (M)Pipe Diameter (in): 11/2 2 21/2 3 4
1. Use only the smallest diameter pipe possible for venting. Over-sizing may cause flame disturbance or excessive vent terminal icing or freeze-up.
2. NA - Not allowed. Pressure switch will not close, or flame disturbance may result.
3. Not all furnace families include 140,000 BTUH input models.
4. Vent sizing for Canadian installations over 4500 ft (1370 M) above sea level are subject to acceptance by local authorities having jurisdiction.
5. Size both the combustion air and vent pipe independently, then use the larger size for both pipes.
6. Assume the two 45� elbows equal one 90� elbow. Wide radius elbows are desirable and may be required in some cases.
7. Elbow and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
8. The minimum pipe length is 5 ft. (2 M) linear feet (meters) for all applications.
9. Use 3-in. (76 mm) diameter vent termination kit for installations requiring 4-in. (102 mm) diameter pipe.
59T
P6A
11
Venting System Length CalculationsThe Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalentlength of elbows used in the venting system from Table 3.Standard vent terminations or factory accessory concentric vent terminations count for zero deduction.See vent system manufacturer’s data for equivalent lengths of flexible vent pipe or other termination systems. DO NOT ASSUME that onefoot of flexible vent pipe equals one foot of straight PVC/ABS DWV vent pipe.Compare the Total Equivalent Vent Length to the Maximum Equivalent Vent Lengths in Table 2.
Example 1A direct-vent 60,000 BTUH furnace installed at 2100 ft. (640M). Venting system includes FOR EACH PIPE:70 feet (22 M) of vent pipe, 65 feet (20 M) of combustion air inlet pipe, (3) 90º long-radius elbows, (2) 45º long-radius elbows, and a factoryaccessory concentric vent kit.Can this application use 2” (50 mm ND) PVC/ABS DWV vent piping?
Measure the required linear length of air inlet andvent pipe; insert the longest of the two here
70 ft.
(22 M)Use length of the longer of the vent or air inlet piping system
Add equiv length of (3) 90º longradius elbows(use the highest number of elbows for either thevent or inlet pipe)
3 x3 ft.
(0.9 M)=
9 ft.(2.7 M)
From Table 3.
Add equiv length of (2) 45º longradius elbows(use the highest number of elbows for either thevent or inlet pipe)
2 x1.5 ft.
(0.5 M)=
3 ft.(0.9 M)
From Table 3.
Add equiv length of factory concentric vent term 0 ft. From Table 3.
Add correction for flexible vent pipe, if any 0 ft.From Vent Manufacturer'sinstructions; zero for PVC/ABS DWV
Total Equivalent Vent Length (TEVL) 82 ft.
(25 M)Add all of the above lines
Maximum Equivalent Vent Length (MEVL) 95 ft.
(29 M)For 2" pipe from Table 2
Is TEVL less than MEVL? YES Therefore, 2" pipe MAY be used
Example 2A direct-vent 60,000 BTUH furnace installed at 2100 ft. (640M). Venting system includes FOR EACH PIPE:100 feet (30 M) of vent pipe, 95 feet (29 M) of combustion air inlet pipe, (3) 90º long-radius elbows, and a polypropylene concentric vent kit.Also includes 20 feet (6.1 M) of flexible polypropylene vent pipe, included within the 100 feet (30 M) of vent pipe.VERIFY FROM POLYPROPYLENE VENT MANUFACTURER’S INSTRUCTIONS for the multiplier correction for flexible vent pipe.Can this application use 60mm o.d. (2”) polypropylene vent piping? If not, what size piping can be used?
Measure the required linear length of RIGID air inlet and vent pipe; insertthe longest of the two here: 100 ft. Of rigid pipe - 20 ft. Of flexible pipe
=
80 ft.(24 M)
Use length of the longer of the vent or air inlet piping system
Add equiv length of (3) 90º longradius elbows(use the highest number of elbows for either thevent or inlet pipe)
3 x5 ft.
(1.5 M)=
15 ft.(4.6 M)
Example from polypropylene vent
manufacturer's instructions, Verify from vent
manufacturer's instructions.
Add equiv length of 45º longradius elbows(use the highest number of elbows for either thevent or inlet pipe)
0 x =0 ft.
(0 M)
Add equiv length of factory concentric vent term 9 x3.3 ft
(0.9 M)=
30 ft.(9 M)
Add correction for flexible vent pipe, if any 2* x20 ft.
(6.1 M)=
36 ft.(11 M)
* VERIFY FROM VENT MANUFACTURER'S INSTRUCTIONS; For example only, assume 1 meter of flexible 60mm (2”) or 80mm (3”)polypropylene pipe equals 2.0 meters (6.5 ft.) of PVC/ABS pipe.
Total Equivalent Vent Length (TEVL) 165 ft.(50 M)
Add all of the above lines
Maximum Equivalent Vent Length (MEVL) 95 ft.
(29 M)For 2" pipe from Table 2
Is TEVL less than MEVL? NOTherefore, 60mm (2”) pipe may NOT beused; try 80mm (3”)
Maximum Equivalent Vent Length (MEVL) 185 ft.(57 M)
For 3" pipe from Table 2
Is TEVL less than MEVL? YES Therefore, 80mm (3”) pipe MAY be used
59T
P6A
12
RETURN AIR TEMPERATUREThis furnace is designed for continuous return−air minimum temperature of 60�F (15�C) db or intermittent operation down to 55�F (13�C)db such as when used with a night setback thermometer. Return−air temperature must not exceed 80�F (27�C) db. Failure to follow thesereturn air limits may affect reliability of heat exchangers, motors and controls.
60
80 / 27˚C
/ 16˚C
SUPPLY AIR
A10490
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALSPOSITION CLEARANCE
Rear 0 (0 mm)Front (Combustion air openings in furnace and in structure) 1 in. (25 mm)
Required for service** 24 in. (610 mm)*All Sides of Supply Plenum** 1 in. (25 mm)
Sides 0 (0 mm)Vent 0 (0 mm)
Top of Furnace 1 in. (25 mm)* Recommended
**Consult your local building codes
COMBUSTION−AIR PIPE FOR NON−DIRECT (1−PIPE) VENT APPLICATION
NOTE: See Installation Instructions for specific venting configurations.
59T
P6A
13
DOWNFLOW SUBBASELOCATING
TAB
LOCATINGTAB
1 2 3 4
4 3 2 1
B
D
C
A
1 1/4-IN. TYP
PLENUMOPENING
FACTORY-SUPPLIEDFIELD-INSTALLED
INSULATION
Assembled Disassembled
A97427 A88207
DIMENSIONS (IN. / MM)
FURNACECASING WIDTH
FURNACE IN DOWNFLOWAPPLICATION
PLENUM OPENING* FLOOR OPENING HOLE NO. FORWIDTH
ADJUSTMENTA B C D
14-3/16 (360) Furnace with or without Cased Coil
Assembly or Coil Box11-3/16
(322)19 (483)
13-7/16(341)
20-5/8(600)
4
17-1/2 (445) Furnace with or without Cased Coil
Assembly or Coil Box15-1/8(384)
19 (483)16-3/4(426)
20-5/8(600)
3
21 (533)Furnace with or without Cased Coil
Assembly or Coil Box18-5/8(396)
19 (483)20-1/4(514)
20-5/8(600)
2
24-1/2 (622)Furnace with or without Cased Coil
Assembly or Coil Box22-1/8(562)
19 (483)23-3/4(603)
20-5/8(600)
1
*The plenum should be constructed 1/4-in. (6 mm) smaller in width and depth than the plenum dimensions shown above.
Concentric Vent KitA93086
A concentric vent kit allows vent and combustion−air pipes toterminate through a single exit in a roof or side wall. One piperuns inside the other allowing venting through the inner pipe andcombustion air to be drawn in through the outer pipe.
Downflow SubbaseA88202
One base fits all furnace sizes. The base is designed to be installedbetween the furnace and a combustible floor when no coil box isused or when a coil box other than a Carrier cased coil is used. It isCSA design certified for use with Carrier branded furnaces wheninstalled in downflow applications.
59T
P6A
14
OPTIONAL MEDIA FILTER CABINET
Media FilterCabinet A B
16" (406mm)20" (508mm)24" (610mm)
17" (432mm)
Furnace Side
Centerline Screw Slots
23-3/4”
23-3/8”
23-5/8"
534
Duct Side
Opening
Opening with Flanges Bent
24-1/4”
25-5/8"
B O
pening
A
"
(600mm)
(594mm)
(603mm)
(146mm)
(651mm)
(616mm)
23-1/8”(588mm)
16" (406mm)20" (508mm)24" (610mm)
21" (533mm)25" (635mm)
NOTE: Media cabinet is matched to the bottom opening on furnace. May also be used for side return.A12428
NOTES: Connect Y-terminal in furnace as shown for proper blower operation.Some thermostats require a "C" terminal connection as shown.If any of the original wire, as supplied, must be replaced, usesame type or equivalent wire.
W
Y
GND
THERMOSTATTERMINALS
1.2.3.
A11387
59T
P6A
15
DIMENSIONAL DRAWING
6 15
/16
[176
.1]
3[7
6.2]
3[7
6.2]
6 11
/16
[170
.1]
23 5
/16
[592
.9]
25 1
/8[6
38.7
]
26 3
/8[6
70.0
]
26
11/1
6[6
78.1
]
21[5
34.0
] 26 5
/16
[668
.8]
17 5
/16
[439
.2]
16 9
/16
[420
.9]
20 1
/4[5
13.9
]25
3/1
6[6
39.1
]28 3
/16
[715
.9] 28
5/8
[726
.4]
32 5
/8[8
29.5
]
28 3
/4[7
30.5
]
26 3
/8[6
69.9
]
26 1
1/16
[678
.1]
21 1
5/16
[557
.4]
21 1
/16
[535
.8]
26 5
/16
[668
.8]
3[7
6.2]
AIR
INTA
KE
1 3/
4[4
4.5]
GA
S CO
NN
7/8
[22.
2]
7/8
[22.
2] P
OW
ER C
ON
N
7/8
[22.
2]
THER
MO
STA
T EN
TRY
7/8
[22.
2]
3[7
6.2]
AIR
INTA
KE1
3/4
[44.
5]G
AS
CON
N7/
8[2
2.2]
7/8
[22.
2]
3[7
6.2
]
7/8
[22.
2]
7/8
[22.
2]TH
ERM
OST
AT
ENTR
Y22
15/
16[5
81.9
]16
9/1
6[4
20.9
]
17 7
/16
[442
.3]
20 1
/4[5
13.9
]
24[6
09.7
]
28 3
/8[7
20.4
]
28 5
/8[7
26.9
]
29 1
3/16
[757
]
23 3
/8[5
92.0
]
3[7
6.2]
VEN
T
1 (B
OTH
SID
ES)
[25.
4]
D
2 3/
10[5
8.4]
CBO
TTO
M R
ETU
RNW
IDTH
11/1
6[1
7.5]
11/1
6[1
7.5]
BO
UTL
ET W
IDTH
A
22[5
58.3
] (BO
TH S
IDES
)
14 1
3/16
[376
.3]
35[8
89.0
]
5/8
[15.
8]
1 5/
16[3
3.3]
29 1
/2[7
49.3
]
19 1
/8[4
85.8
]
20 5
/8[5
22.7
]
23 7
/16
[595
.6]
[101
.6]4
[63.
5]2
1/2
18 1
/16
[458
.6]
2 1/
2[6
3.5]
4[1
01.6
]
20 5
/8[5
22.7
]
BOTT
OM
INLE
T 2
1 5/
8 [5
49.5
]
6 1/
16[1
54.0
]
PAR
T NU
MBE
R
S
D502
4-4
SH
T 1
RE
V E N
EXT
SHEE
T
2
VEN
T
AIR
INTA
KE
AIR
FLO
WA
IR F
LOW
SID
E IN
LET
SID
E IN
LET
CON
DEN
SATE
DRA
IN T
RAP
LOCA
TIO
N
NO
TE: A
LL D
IMEN
SIO
NS
IN IN
CH [M
M]
[22.
2]7/8
7/8
[22.
2] P
OW
ER C
ON
N
AIR
FLO
W
SEE
NO
TE #
3
NO
TES:
1. D
oors
may
var
y by
mod
el.
2. M
inim
um re
turn
-air
open
ings
at f
urna
ce, b
ased
on
met
al d
uct.
If fle
x du
ct is
use
d,
s
ee fl
ex d
uct m
anuf
actu
rer's
reco
mm
enda
tions
for e
quiv
alen
t dia
met
ers.
a. F
or 8
00 C
FM-1
6-in
. (40
6 m
m) r
ound
or 1
4 1/
2 x
12-in
. (36
8 x
305
mm
) rec
tang
le.
b. F
or 1
200
CFM
-20-
in. (
508
mm
) rou
nd o
r 14
1/2
x 19
1/2
-in. (
368
x 49
5 m
m) r
ecta
ngle
. c
. For
160
0 CF
M-2
2-in
. (55
9 m
m) r
ound
or 1
4 1/
2 x
22 1
/16-
in. (
368
x 56
0mm
) rec
tang
le.
d. R
etur
n ai
r abo
ve 1
800
CFM
at 0
.5 in
. w.c
. ESP
on
24.5
" cas
ing,
requ
ires
one
of th
e fo
llow
ing
confi
gura
tions
: 2 s
ides
, 1 s
ide
and
a bo
ttom
or b
otto
m o
nly.
See
Air
Del
iver
y ta
ble
in th
is
docu
men
t for
spe
cific
use
to a
llow
for s
uffici
ent a
irflow
to th
e fu
rnac
e.3.
Ven
t and
Com
bust
ion
air p
ipes
thro
ugh
blow
er c
ompa
rtm
ent m
ust
u
se a
cces
sory
“Ven
t Kit
- Thr
ough
the
Cabi
net”
. See
acc
esso
ry li
st fo
r
cur
rent
par
t num
ber.
TOP
VIEW
A12267
59TP6AFURNACE SIZE
A B C D SHIP WT.LB (KG)CABINET WIDTH OUTLET WIDTH BOTTOM INLET WIDTH AIR INTAKE
GUIDE SPECIFICATIONSGeneralSystem DescriptionFurnish a ______________________ 4−way multipoise gas−firedcondensing furnace for use with natural gas or propane (factory−authorized conversion kit required for propane); furnish externalmedia cabinet for use with accessory media filter or standard filter.
Quality AssuranceUnit will be designed, tested and constructed to the current ANSI Z21.47/CSA 2.3 design standard for gas−fired central furnaces.Unit will be third party certified by CSA to the current ANSI Z21.47/CSA 2.3 design standard for gas−fired central furnaces. Unitwill carry the CSA Blue Star� and Blue Flame� labels. Unitefficiency testing will be performed per the current DOE testprocedure as listed in the Federal Register.Unit will be certified for capacity and efficiency and listed in thelatest AHRI Consumer’s Directory of Certified Efficiency Ratings.Unit will carry the current Federal Trade Commission EnergyGuide efficiency label.
Delivery, Storage, and HandlingUnit will be shipped as single package only and is stored andhandled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)U.S. and Canada only. Warranty certificate available upon request.
EquipmentBlower Wheel and ECM Blower MotorGalvanized blower wheel shall be centrifugal type, statically anddynamically balanced. Blower motor of ECM type shall bepermanently lubricated with sealed ball bearings, of _______hp,and have infinitely variable speed from 600−1200 RPM operatingonly when motor inputs are provided. Blower motor shall be directdrive and soft mounted to the blower housing to reduce vibrationtransmission.FiltersFurnace shall have reusable−type filters. Filter shall be ______ in.(mm) X ________ in. (mm). An accessory highly efficient MediaFilter is available as an option. _____________ Media Filter.
CasingCasing shall be of .030 in. thickness minimum, pre−painted steel.Draft Inducer Motor
Draft inducer motor shall be two−speed PSC design.
Primary Heat Exchangers
Primary heat exchangers shall be 3−Pass corrosion−resistantaluminized steel of fold−and−crimp sectional design and appliedoperating under negative pressure.
Secondary Heat ExchangersSecondary heat exchangers shall be of a stainless steelflow−through of fin−and−tube design and applied operating undernegative pressure.Controls
Controls shall include a micro−processor−based integratedelectronic control board with at least 16 service troubleshootingcodes displayed via diagnostic flashing LED light on the control, aself−test feature that checks all major functions of the furnace, anda replaceable automotive−type circuit protection fuse. Multipleoperational settings available, including separate blower speeds forlow heat, high heat, low cooling, high cooling and continuous fan.Continuous fan speed may be adjusted from the thermostat.Cooling airflow will be selectable between 325 to 400 CFM perton of air conditioning. Features will also include temporaryreduced airflow in the cooling mode for improveddehumidification when a TP−PRH is selected as the thermostat.
Operating CharacteristicsHeating capacity shall be _________________ Btuh input;______________ Btuh output capacity.Fuel Gas Efficiency shall be________ AFUE.
Air delivery shall be ________________ cfm minimum at 0.50 in.W.C. external static pressure.
Dimensions shall be: depth_________in. (mm); width__________in. (mm); height___________in. (mm) (casing only).Height shall be _________in. (mm) with A/C coil and_________________in. (mm) overall with plenum.
Electrical RequirementsElectrical supply shall be 115 volts, 60 Hz, single−phase (nominal).Minimum wire size shall be ________AWG; maximum fuse sizeof HACR−type designated circuit breaker shall be _________amps.
Special FeaturesRefer to section of the product data identifying accessories anddescriptions for specific features and available enhancements.
Copyright 2017 Carrier Corp. � 7310 W. Morris St. � Indianapolis, IN 46231 Edition Date:11/17
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.