GP/1F
PERIODIC I SPECTION REPORTFORAN ELECTRICAL INSTALLATIONIssued in accordance with British Standard BS 7671- Requ
See reve"e of this page for e.planalol'( notes relating to NICEICsoftware endo"emenl
Date of previous inspection: ~OT I..( f\C) 1-.) (\ Electrical Installation Certificate No or previous Periodic Inspection Report No: NA
Records of installation available: N f\- Records held by:
. b.-EXTENT OF THE INSTALLATION1AND'LlMITATIONS:OF~THErjNS-PEtTlbN' A'i\f5"tESTING· _,
Extent of the electrical installation covered by this report
A- ~ \(\~pQ..d=.'O" o\- ~~ ,",''ICed ~Irl~ AS PerClrc\..)11:: cte..~I~
Agreed limitations, if any, on the inspection and testing:
:ScOla o\- Ac~o\\Q»~ A-cQ.5S
T ~~~ V\o..J..)Q..
'-.)~ \(\A.a_d~ 0....'000::2... ~ 0...\ ~.Q
~ re.Mo.:ec) I
CQ.J.ll~ •
This inspection has been carried out ifl accordance with BS 7671: 2001, as amended. Cables concealed within trunking and conduits, or cables and conduits con-cealed under floors, in inaccessible roof spaces and generally within the fabric of the building or underground, have not been visually inspected.
E. DECLARATIONWle,being the person(s)responsiblefor the inspeefion andtesting of the electrical installation (as indicated bymy/our signaturesbelow), particulars of which are described above (see C), havingexercised reasonableskill and care when carrying out the inspection and te~ng, hereby declare that the informa~onin this report. including the observations [see F) and the attached schedules(see HI, providesan accurate assessmentof the condition of the electrical instaUatiootaking into account the stated extentof the installation andthe limitationsof the inspectionand testing (see 0),I/We further declare that in my/our judgement. the said installation was overall in"$ \ _ t condition (see G) al the time the inspectionwas carried out and that it should be further inspected as recommended (see I). .. Q.~\ ~rctc,k:;"o r,--\
(Insert 'a satisfactory' or 'an unsmisfBctory: as appropriate)
G AND ASSESSMENT BY: REPORT REVIEWED AND CONFIRMED BY: t See note below
Signature:
Name:(CAPITALS)
Name:(CAPITALS)
Position:
Date:Date:
Page 1 of rnt The completed report should preferably be reviewed by another competent person to confirm that the declared overall condition of the electrical installationIS consistent with the inspection and test results, and with the observations and recommendations for action (if anyl made in the report
F. OBSERVATIONS AND RECOMMENDATIONS FOR ACTIONS TO BE TAKENReferring to the attached schedules of inspection and test results, and subject to thvunitations at 0:
There are no items adversely .affecting electrical safety. Vor
The followinq observations and recommendations are made.Code tItem Ne
1.1
II!~
::
J
II"!
:1II ~~u t:ft'I I
RB
Nota: If I>BCessary;continue on'Bddiri(Jna/ pages(s}, which must fle id~mified l1ytM Periodic Inspection ".porr date'Bnd pagl! number(s}.
t Where observations are made, the Inspector wifJ have entered one of the following codes against each observation to indicate the action (if any) recommended:I. 'requires urgent attention' Dr 2. 'requires improvement' or3. 'requires further investigation' or f. 'does Dot complv with BS 7677: 2001'
Please see the reverse of this page for guidance regarding the recommendations.
Urgent remedial work recommended for Items: Corrective action(s) recommended for Items;
G. SUMMARY OF THE INSPECTIONGeneral condition of the installation:
-r\-..Q_ \ (\~~o...LL oJ=, 0 (\,
Note: If necessary; continue on additional pagels), which must be identified by the Periodic Inspection "eport date and page numbetis).
Date(s) ofthe inspection: ~,. ~C)\.) \ 1- ~fth:~n~~~Ii~ti~::nt So,_\c:-\ s, ~c?'("-i~(Entry should read either 'Satisfactory' or 'Unsatisfactory?
Please see the 'Guidance forRecipients on the RecommendationCodes' on the reverse of this page.
GPf2F
CISCC).;::o
Schedule of Items Inspected and Schedules of Items Tested: Page No 4 Additional pages, including additionalsourcels) data sheets; Page No(s)
H. SCHEDULES AND ADDITIONAL PAGES
Schedule of CirGuit Details for the Installation: Page Nols) 5 Schedule ,of Test Results for the Installation: Page No(s) 6
The pages identified flere form an essential part of this report The report is valid only if accompanied by all the schedules and additional pages identified above.
lEnter interval in terms of wars, months or weeks, 85appropriaC8/
I. NEXT INSPECTIONINVe recommend that this installation is further inspected and tested after an interval of not more than
provided that any items at F which have been attributed a Recommendation Code 1 (requires urgent attention) are remedied withoutdelay. Items which have been attributed a Recommendation Code 2 or 3 should be actioned as soon as practicable (see F).
Nature of Supply Parameters + Characteristics of Primary SupplyNominal UI1! '1"2 _ V U /II I'} ., V Overcurrent Protective Device(s)
voltage{s): cs-» .~-O
TT
v'!1.phase1 (2w!re)
i2·phas~t (,wireli 3>phase
1130
::
_-l.phase."...,-- 13wlrel
2pole
3·pole
Please stateIT
l. PARTICULARS OF INSTAllATION AT THE ORIGIN+Means of Earthing :Supplier's ! Type:tacillty: ."...-! leg rod{s),tapeetc)
Tick boxes and enter details, 8S appropriate
Details of Installation Earth Electrode (where applicable)
~AInstallation 1\ I i Electrode (Q) Method ofearth electrode: IN'"' j resistance, RJ\: ~A- measurement N f\......._.___.__._-_:.___ - -..- -..- -~,-..- ..-..---.--.-~-.-.-.-- --- - ~.._ ..--.-..._-_..____..-._-====
·z·Main Switch or Circuit-Breakilr iMaximum A per j Method of ProtectIon A A. S{8ppffcabl8onlywflere8nRCO/$suitBblealldisU$1dIlS8tT18incircuit·bre8~rljDemarnl (Load}: .4S phase + againstlndirect Contact • V'Type: . Voltage ~-r····-·····-·-·-··----··--·""-~·~-MainProtedi;,e~ConiiUct;s-·~-~-~~··'---·~·---· -~--~-BS(ENj (0\ 00 ~ fating ~O V : Earthing conductor ; Main BquipolBntial bonding conductors! Bonding of exlraneous-conductive·parts (.r)
No of current! Conduqor r- _[\n J I Conductor r"'_ fV\ J I Water Gas servicePoles ~O rating, In \oo A ! matenal '-0"1" "'-V\'-_ material \",..Q¥\'Ol.- service __
~,.- ......DO-.D RCDoperating • .2>..9~A t Conductor \ I _ mm' !... Condll~~~ \ 0 mm- :,. servi~~materiel 'I...LJ"{,"~" currentliln'~" f csa 'C)
Sc,uppL 11 c+ a rnm' RCDoperating;..". 0 ms! Continuity .-.-I ..r) .,',',Continu"" check .-t.r) ! LightningC:W"~.. 1-...::::. • time (at It.n)·' I. -, i check ~ , "7 .......... \ Iprotection
Location:
Structuralsteel
Other incomingserviceisl
.;. VVhere a number of sources are available to supply the installation and where the data given for the primary source may differ fromother sources, a separate sheet must be provided which identifies the relevant information relating to each additional source.
Presence of supplementary equipotential bondingconductors
Presence of earthing_arrangements for combinedprotective andluncnonal purposesPresence of adequate arrangements for alternativesource(s), where applicable
Presence of residual current device(s)
General~esence and correct location of appropriate devices for
isolation and switching
/ Adequacy of access to switchgear and other equipment
Nf.\ Particular protective measures for special installations and locations
_....tonnection of single-pole devices for protection or~ switching in phase conductors only
~ Correct connection of accessories and equipment
h.) f'; Presence of undervoltage protective devices
_.....-choice and setting of protective and monitoring devicesyr (fOF protection against indirect contact and/or overcurrent)~election of equipment and protective measures
appropriate to external influences
/seleCtion of appropriate functional switching devices
'--protection by separation of circuits
~ Protection against direct contact by barrier or enclosure~ provided during erection
...,........,Insulation of non-conducting floors or walls
--Polarity
.......-Earth fault loop impedance, Is"""-Operation of residual current devices
v"Functional testing of assemblies
SCHEDULE OF ITEMS TESTED
v" Oi) Use of Class Il equipment or equivalent insulation
(iv) Earth-free equipotential bonding:Presence of earth-free equipotential bonding conductors
(v] Electrical separation
+ See note below
~emal earth fault loop impedance, Z.
H
'Ii
~~£~ r,('
-g:;;c.
£~cacC)
-.::0
Installation earth electrode resistance, RA
~ontinuity of protective conductors
/"" Continuity of ring final circuit conductors
.,/ Insulation resistance between live conductors
/ Insulation resistance between live conductors and earth
"l(\ Site applied insulation
t All boxes must be completed.V' indicates that an inspection or a test was carried out and that the result was satisfactory')C' indicates that an inspection or a test was carried out and that the result was unsatisfactory
'N/A' indicates that an inspection or a test was not applicable to the particular installation
'LIM' indicates that exceptionally, a limitation agreed with the person ordering the work
(as recorded in Section Dj prevented the inspection or test being carried outPage40f L1f
ta ~"'o~ct C+- \ \ 110.0 1'2...~ .l.... ~~C\K R. 'K"2.. b ~D 1\ .w..
t See Table 4A1 of Appendix 4 of 8S 7671: 2001
CODES FOR TYPE OF WIRINGA B C D E F G H o (Other· please state)
PVC/PVC PVCcables PVCcables PVCcables PVCcables PVC/SWA XLPE/SWA Mineral·cables in metallic in non·metallic in metallic in non-metallic cables cables insulated
conduit conduit trunking trunking cablesPage 5 of [3J
GP/SF
* In such cases, details of the distribution (sub-main) circuit(s), together with the test results for the circuit(s), must also be provided.
See reve rse of page 1 for explanatory notes relating to NICEICsoftware endorsement
ONLYTO BE COMPlETED IF THE OIS11lll!UTIOI1I BOARD IS NOT CONNECTED Test instruments (serial numbers) used:- IIIIIEtTl.Y TOTHE OIIIGIN OF THE INSTAllATION
Earth fault loop J"* S•• fIfl!SbO'O>t Charaj:18ristic$ at Ibis 8i.stributiD~board o Li. ..", -~'"RCDimpedance - ,I -
Z. I" Q. Operating times AtlMI ~msInsulation 1 Other I ~resistance - \ \ - ~A
'Ii of assoctatadIPf ~ RCO (if any) At51M L, jn: Continuity Other I N1" Ilil~r s - \\ - ~
,Ring fina:dc!;:tr: on~ AII'Circoits I'llase/Phase t .- Phase~arth't :~ .C faukloop,C-E_ ,"."..,,"""'.. impeQance.z. ailM at SiAn;t:::."O I to en I (At l(!ast onHolul!IO_.e ~
" Note: Where the Instal/allan can be supplied by more than one source, such 8S a pnmary source (eg public supply) and a secondary source (eg standby generator), the higher or highestvalues mu ded"