Perforated Plate Column Liquid – Liquid Extraction Equipment Fawad Akram 12063123-065 B.Sc Chemical Engineering, UoG.
23
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Perforated plate column - LLE Equipment

Perforated Plate Column

Liquid – Liquid Extraction Equipment

Fawad Akram12063123-065

B.Sc Chemical Engineering, UoG.

Page 2: Perforated plate column - LLE Equipment

Liquid – Liquid Extraction Equipment

• LLE involves intimate contact between two immiscible or partially liquid phases as compared to a gas or a vapor and a liquid phase in gas absorption and distillation.

Page 3: Perforated plate column - LLE Equipment

What are differences between these fluid - fluid contacting phenomena??

Page 4: Perforated plate column - LLE Equipment

Liquid – Liquid Extraction is more difficult than distillation.

Page 5: Perforated plate column - LLE Equipment

Liquid – Liquid Extraction has higher energy demand than distillation.

Page 6: Perforated plate column - LLE Equipment

Commerical Extractors

Page 7: Perforated plate column - LLE Equipment

Design of ExtractorsStage-wise ContactorsDifferential Contactors

Page 8: Perforated plate column - LLE Equipment

Factors classifying Contactors

• Inducement of countercurrent flow• Designing• Effecting Phase Separation

Page 9: Perforated plate column - LLE Equipment

PERFORATED PLATE COLUMNS

Page 10: Perforated plate column - LLE Equipment

• Similar to the sieve tray columns in distillation.• The column is comprised of several perforated trays

along with either downcomers or upcomers, depending on which phase, heavy or light, is chosen to be continuous.

• The original dispersion is performed by a nozzle, as in spray columns.

• Cross flow contact occurs between each tray.

Page 11: Perforated plate column - LLE Equipment

• Sieve tray columns are stagewise contactors due to coalescence of the dispersed phase between trays and its redistribution through the perforations in the tray.

• It is important that the internals be coated with the continuous phase.

Page 12: Perforated plate column - LLE Equipment
Page 13: Perforated plate column - LLE Equipment
Page 14: Perforated plate column - LLE Equipment

Design of Perforated Plate ExtractionColumns

• Procedure developed by Skelland and Chada.• Procedure involves use of rate equations for mass

transfer during drop formation either at the perforations or at the end of jets issuing from the perforations, during free rise or fall of the drops, and during coalescence beneath each plate, to locate a pseudo-equilibrium curve.

• When flow rates of the disperse phase are low, drop formation and detachment occur at the perforations on each plate.

Page 15: Perforated plate column - LLE Equipment

Design of Perforated Plate ExtractionColumns

• At higher flow rates, however, drops form at the tips of jets emerging from the perforations.

• Figure shows the nth stage of a perforated plate extraction column, where transfer is from the continuous phase to the disperse phase.

Page 16: Perforated plate column - LLE Equipment

Design of Perforated Plate ExtractionColumns

• Drop formation is taking place under jetting conditions and the agitation resulting from motion of the droplets ensures constancy of for a given stage.

• The mass transfer rate in stage n can be written in terms of the disperse phase as:

Page 17: Perforated plate column - LLE Equipment

Design of Perforated Plate ExtractionColumns

• But

• If the variation in D over stage n is slight,

• Insertion in Eq. i results in:

Page 18: Perforated plate column - LLE Equipment

Design of Perforated Plate ExtractionColumns

• c

• Next, the assumption is made either that solute transfer is accompanied by equi-molal countertransfer of solvents between phases or that only solute (A) is transferred. Then,

Page 19: Perforated plate column - LLE Equipment

Design of Perforated Plate ExtractionColumns

• If the inlet for D is at section 2 of the column, a material balance on non-A gives

• A trial-and-error process will yield , corresponding to a given pair of and values in the following way, if , , , , , and are all predictable:

Page 20: Perforated plate column - LLE Equipment

Design of Perforated Plate ExtractionColumns

1. A value of , is assumed, corresponding to a given pair of and , values in Fig.

2. and corresponding to and the assumed are calculated next from Eqs. Given on previous slide.

3. Values of q are computed from Eqs. On slide 18.

Page 21: Perforated plate column - LLE Equipment

Design of Perforated Plate ExtractionColumns

• The value assumed for , is correct when these two estimates of q coincide.

• This enables construction of the pseudoequilibrium curve, which is then used with the operating curve to step off the number of real plates needed to accomplish the desired change in D-phase composition from to .

Page 22: Perforated plate column - LLE Equipment

Design of Perforated Plate ExtractionColumns

Page 23: Perforated plate column - LLE Equipment