OS License Number : 100020449 Stage 1 Preliminary Ground Investigation at Kegworth Factual Report for Waterman Transport and Developments Limited Project Number : PC124998 October 2012 Issuing office : Head Office Coventry Geotechnics Limited The Geotechnical Centre 203 Torrington Avenue Tile Hill Coventry CV4 9AP T: 024 7669 4664 F: 024 7669 4642 [email protected]North West Office Geotechnics Limited The Geotechnical Centre Unit 1, Borders Industrial Park River Lane, Saltney Chester CH4 8RJ T: 01244 671 117 F: 01244 671 122 [email protected]South West Office Geotechnics Limited The Geotechnical Centre 7 Pinbrook Units Venny Bridge Exeter EX4 8JQ T: 01392 463 110 F:01392 463 111 [email protected]Geotechnics Limited, Registered in England No. 1757790 at The Geotechnical Centre, 203 Torrington Avenue, Tile Hill, Coventry CV4 9AP
90
Embed
PC124998 Factual Report - Planning Inspectorate · 2016-05-12 · APPENDIX 4 Cable Percussion and Rotary Borehole Records ... Factual Report, Project No PC124998, October 2012. 203
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Strata, Continued Mudstone Siltstone Metamorphic Rock
Fine Grained Medium Grained Coarse Grained Igneous Rock
Fine Grained Medium Grained Coarse Grained
Backfill Materials Arisings Bentonite Seal Concrete Fine Gravel Filter General Fill Gravel Filter Grout Sand Filter Tarmacadam
Rotary Core
RQD Rock Quality Designation (% of intact core >100mm) FRACTURE INDEX Fractures/metre FRACTURE Maximum SPACING (mm) Minimum NI Non-intact core NR No core recovery AZCL Assumed zone of core
loss (where core recovery is unknown it is assumed to be at the base of the run)
BOREHOLE RECORDProject
Client
Engineer BoreholeProject No
Sampling Properties Strata
DepthSampleType kPa
w%
Scale
Description Depth Legend
Boring Groundwater
Depth Dia Technique Crew of Hole Cased Water Date Struck Cased Rose to Sealed Groundwater
Remarks
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
Time Mins
DepthCased &
(to Water)Strength
ProgressDepth Depth Depth to Depth Depth Depth Remarks oninHole
KEGWORTH WATERMAN TRANSPORT & DEVELOPMENT LTD PC124998
G.L. 65.39 Grass over soft to firm brown slightly sandy slightly gravelly clay. Gravel is angular to subangular fine to medium sandstone.. 0.20 65.19
0.20- 0.90 B [TOPSOIL]
Firm reddish brown slightly sandy slightly gravelly CLAY with rare roots up to 2mm in diameter. Gravel is subangular fine to medium reddish brown and yellowish brown fine grained sandstone. [MERCIA MUDSTONE WEATHERING GRADE IVB]
0.90- 1.20 B 0.90 64.49 Firm reddish brown slightly sandy varying to sandy CLAY with occasional angular to subangular fine to medium gravel sized pockets of light bluish grey clayey fine sand.
1.20- 1.65 B 20 [MERCIA MUDSTONE WEATHERING GRADE IVA] 1.20- 1.65 D Between 0.90-1.20m, with rare relict root tracks. 1.20- 1.65 S13
1.80 D
2.00- 2.45 B Below 2.00m, fissured. Fissures are extremely 2.00- 2.45 D 1.80 15 S12 closely to very closely spaced, randomly
(DRY) orientated, dull, undulating or stepped.
2.80 D 2.80 62.59 Stiff becoming very stiff fissured reddish brown slightly mottled light bluish grey slightly sandy
3.00- 3.45 B varying to sandy CLAY with frequent angular gravel 3.00- 3.45 D 3.00 12 S40 sized lithorelicts. Fissures are extremely closely
(DRY) to very closely spaced, randomly orientated, dull, undulating or stepped. [MERCIA MUDSTONE WEATHERING GRADE III] Below 3.00m, very stiff.
At 3.80m, recovered as angular gravel sized 3.80 D fragments of extremely weak to weak reddish brown
occasionally light bluish grey siltstone, tending to fine grained sandstone with some firm slightly
Inspection pit hand excavated to 1.20m depth. Chiselling from 6.50-6.80m for 1 hr. Packer Permeability tests were carried out after drilling at depths of 13.50-14.50m, 16.00-17.00m,and 20.00-21.00m on 04/09/2012. A 20mm standpipe was installed to 27.60m with a geowrapped slotted section from 14.00m to 27.60m with flush lockable protective cover. Backfill details from base of hole: gravel filter up to 14.00m, bentonite seal up to 0.30m, concrete up to ground level. Chiselling: 6.50-6.80m for 60 minutes.
Cable Percussion and Rotary CP/RC101
National Grid ENCoordinates
1:25 Ground Level m OD
Levelm OD
SPT N(FI)
Logged by LJ
Logged in accordance with BS5930:1999 + A2:2010
Figure 1 of 6 29/10/2012
BOREHOLE RECORD
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
KEGWORTH WATERMAN TRANSPORT & DEVELOPMENT LTD PC124998
5.00- 5.45 3.00 C50/ Below 5.00m, recovered with gravel of extremely (DRY) 295 weak to weak angular/tabular thickly laminated
mudstone and siltstone.
5.80 D
6.00- 6.45 B 19 6.00- 6.29 3.00 C50/
(DRY) 144
6.50 58.89 Extremely weak thickly laminated reddish brown and brown MUDSTONE and siltstone. Recovered as angular/tabular gravel sized fragments with much soft sandy clay.
7.30- 8.30 84 0.06 0 (NR) Extremely weak to weak Between 7.30-7.50m, 45 0.02 thickly laminated varying assumed zone of core
(NI) to thinly interbedded loss. reddish brown SILTSTONE and mudstone with occasional light greenish
7.85- 7.90 C grey bands of fine grained sandstone.
(25) Subhorizontal Between 8.05-8.15m & discontinuities extremely 8.95-9.05m, undulating closely to closely subvertical fracturing. spaced, dull and undulating, occasionally Between 8.30-8.50m, slight micaceous with assumed zone of core
10.25 55.14 Very weak to weak reddish Occasional becoming rare
(7) brown and light greenish fine to medium gravel grey fine grained sized open voids.
10.50-10.85 C SANDSTONE. [MERCIA MUDSTONE WEATHERING GRADE II]
(3)
10.95 54.44 (12) Very weak to weak thinly Between 11.05-11.20m,
interbedded reddish brown recovered as extremely (NI) SILTSTONE and mudstone weak angular gravel with
11.10-12.60 100 0.17 45 with rare light greenish some firm clay. 81 0.03 grey fine grained
sandstone bands up to 30mm in thickness. Subhorizontal discontinuities extremely closely to closely spaced undulating, occasionally sub planar, dull, occasionally slightly micaceous.
(11) [MERCIA MUDSTONE WEATHERING GRADE II]
Between 12.00-12.15m, 12.05-12.20 C sandstone bands with
occasional fine gravel sized open voids.
Below 12.35m, extremely weak, occasionally thickly laminated, discontinuities with occasional clay infill up to 5mm in thickness.
12.60-14.10 87 0.16 30 (NR) Between 12.60-12.80m, 49 0.01 assumed zone of core
loss.
(19)
13.10-13.20 C
(>25) 13.50-14.50 PKR
13.60 51.79 (12) Very weak to weak Occasional fine gravel
reddish brown fine sized open voids. grained SANDSTONE. At 13.70m, light grey 13.80 51.59 [MERCIA MUDSTONE calcareous stain.
17.20-17.32 C greenish grey siltstone and fine grained sandstone. Subhorizontal Between 17.45-17.85m, discontinuities extremely 18.25-18.50m, closely to closely spaced 18.60-19.10m & undulating or subplanar, 19.50-19.53m, undulating dull and slightly and stepped micaceous with occasional discontinuity with
G.L. 54.82 0.00- 0.50 B Soft to firm brown slightly sandy slightly gravelly
clay. Gravel is angular fine to coarse light yellowish brown siltstone and reddish brown 0.20 54.62 mudstone. [TOPSOIL]
Firm reddish brown slightly mottled light bluish 0.50- 1.20 B grey slightly sandy slightly gravelly CLAY with 0.50 54.32
rare to occasional angular fine gravel sized lithorelicts. Gravel is angular fine to coarse light bluish grey siltstone. [MERCIA MUDSTONE WEATHERING GRADE IVB]
Firm becoming stiff and very stiff reddish brown occasional mottled light bluish grey fissured slightly sandy slightly gravelly CLAY with occasional angular to subangular gravel sized lithorelicts. Fissures are extremely closely to very closely spaced, randomly orientated, dull,
1.20- 1.65 B 18 stepped. Gravel is light bluish grey angular fine 1.20- 1.56 C50/ to coarse siltstone.
207 [MERCIA MUDSTONE WEATHERING GRADE III]
1.80 D 1.80 53.02 Extremely weak light bluish grey SILTSTONE, tending to fine grained sandstone. Recovered as angular
2.00- 2.45 B 14 gravel sized fragments of light bluish grey 2.00- 2.12 1.80 C50/56 siltstone with rare fragments of reddish brown
(DRY) mudstone.
[MERCIA MUDSTONE WEATHERING GRADE II] Below 2.90m, becoming medium strong and slightly calcareous.
2.40- 2.53 1.80 C50/61 (DRY)
2.80 52.02
Extremely weak to weak 2.80- 4.10 98 0.11 17 thickly laminated to
77 0.01 thinly interbedded reddish brown MUDSTONE and light greenish grey siltstone. Subhorizontal
(16) discontinuities extremely closely to closely spaced, dull and undulating, occasionally slightly micaceous. [MERCIA MUDSTONE WEATHERING GRADE II]
At 3.90m, with rare medium gravel sized
4.00- 4.10 C voids. Between 4.10-4.34m, assumed zone of core
4.10- 5.60 83 0.16 45 loss. 70 0.02 (NR)
(16) 4.45 50.37 Very weak to weak light greenish grey occasionally reddish brown slightly calcareous fine to medium grained SANDSTONE with occasional to frequent undulating layers and lenses of reddish brown mudstone
Inspection pit hand excavated to 1.20m depth. Chiselling from 1.50-2.40m for 2hrs. A 20mm standpipe was installed to 17.20m with a geowrapped slotted section from 4.00m to 17.20m with flush lockable protective cover. Backfill details from base of hole: gravel fill up to 4.00m, bentonite seal up to 0.30m, concrete up to ground level. Chiselling: 1.80-2.00m for 60 minutes and 2.00-2.40m for 60 minutes.
Cable Percussion and Rotary CP/RC102
National Grid ENCoordinates
1:25 Ground Level m OD
Levelm OD
SPT N(FI)
Core RunCore Dia
Depth Cased
TCR/SCR %
Length Max/Min
RQD %
SPT (FI)
Continued by Rotary techniquesGeneral Detail
Logged by LJ
Logged in accordance with BS5930:1999 + A2:2010
Figure 1 of 4 29/10/2012
BOREHOLE RECORDProject
Client
Engineer BoreholeProject No
Drilling Properties/Sampling Strata
Core Run/Depth
ScaleDescription
Depth LegendLengthMax/Min
RQD%TCR/SCR Detail
DescriptionGeneral
Depth Type(Core Dia)
Drilling GroundwaterDepth Technique Crew Depth
of HoleDepthCased
Depth toWater
Date DepthStruck
DepthCased
Rose to DepthSealed
Remarks onGroundwater
Remarks
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
TimeMinsin
DiaHole
%Cased &
(to Water)
Progress
KEGWORTH WATERMAN TRANSPORT & DEVELOPMENT LTD PC124998
Subhorizontal discontinuities very At 5.35m, 5.50m, 5.70m, closely to medium spaced 6.75m, 6.95m, 7.70m, undulating on stepped 9.05m & 9.30-9.45m, some with slight clay smear or gravel sized voids on infill up to 5mm in lenses with occasional thickness. calcareous infill.
(6) light reddish brown varying to reddish brown slightly calcareous fine to medium grained
11.20-12.70 100 0.20 54 SANDSTONE with occasional 87 0.04 to frequent undulating
reddish brown mudstone layers and lenses between
11.45-11.65 C 1-20mm in thickness.
Subhorizontal discontinuities very
(7) closely to medium spaced, undulating or stepped with slight clay smear on At 11.90m, 13.58m, clay infill up to 3mm in 13.75m & 15.60m, stiff thickness. reddish brown clay bands [MERCIA MUDSTONE between 5-20mm in WEATHERING GRADE I] thickness.
Between 12.30-12.45m, weak.
(20)
(8)
12.70-14.20 97 0.34 73 87 0.07 (5) Between 12.83-12.90m,
undulating subvertical discontinuity with slight dark brown stain. At 12.95m and 13.95m, fine to medium gravel sized voids with some carbonous infill.
(3)
Between 14.05-15.15m, occasional coarse sand to medium gravel sized open voids.
14.20-15.70 100 0.26 67 96 0.02
(7)
Cable Percussion and Rotary CP/RC102
National Grid ENCoordinates
1:25 Ground Level m OD
Levelm OD
SPT N(FI)
Logged by LJ
Logged in accordance with BS5930:1999 + A2:2010
Figure 3 of 4 29/10/2012
BOREHOLE RECORDProject
Client
Engineer BoreholeProject No
Drilling Properties/Sampling Strata
Core Run/Depth
ScaleDescription
Depth LegendLengthMax/Min
RQD%TCR/SCR Detail
DescriptionGeneral
Depth Type(Core Dia)
Drilling GroundwaterDepth Technique Crew Depth
of HoleDepthCased
Depth toWater
Date DepthStruck
DepthCased
Rose to DepthSealed
Remarks onGroundwater
Remarks
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
TimeMinsin
DiaHole
%Cased &
(to Water)
Progress
KEGWORTH WATERMAN TRANSPORT & DEVELOPMENT LTD PC124998
15.20 39.62 Weak to medium strong reddish brown SILTSTONE grading to mudstone.
(9) Subhorizontal discontinuities very closely to closely At 15.60m, very stiff spaced, undulating on reddish brown clay bands stepped dull with clay 5mm in thickness. 15.70 39.12
WEATHERING GRADE I] discontinuity with a little dark grey stain, dip 80 degrees.
Weak to medium strong Subhorizontal light greenish grey discontinuities very becoming reddish brown closely to medium slightly calcareous fine spaced, undulating with grained SANDSTONE with clay smear.
(5) very thinly to medium Between 16.10-17.00m, interbedded layers of with rare fine to coarse very stiff reddish brown gravel sized voids with sandy clay between 5-90mm occasional calcareous in thickness. infill. [MERCIA MUDSTONE WEATHERING GRADE I]
G.L. 80.56 0.00- 0.20 B Grass over firm brown slightly sandy slightly
gravelly clay with rootlets and roots up to 2mm in diameter. Gravel is angular fine asphalt. 0.20 80.36 [MADE GROUND]
Firm reddish brown occasionally mottled light bluish grey slightly sandy CLAY with occasional
0.50- 1.20 B 17 angular to subangular fine to coarse gravel sized lithorelicts. [MERCIA MUDSTONE WEATHERING GRADE IVB]
1.20 79.36 1.20- 1.65 B Stiff becoming very stiff fissured reddish brown 1.20- 1.65 D 14 S16 slightly mottled light bluish grey slightly sandy
CLAY with angular to subangular fine to coarse gravel sized lithorelicts. Fissures are extremely closely to very closely spaced, randomly orientated, dull, undulating or stepped. [MERCIA MUDSTONE WEATHERING GRADE III]
A Packer Permeability test was carried out after drilling at a depths of 15.00-16.00m on 10/09/2012. A 20mm standpipe piezometer was installed to 15.00m with a slotted section from 12.00m to 16.00m; 24/09/2012 - Unable to monitor - Flooded. and a 20mm standpipe was installed to 5.00m with a geowrapped slotted section from 1.00m to 5.00m with flush lockable protective cover; 24/09/2012 - Unable to monitor - Flooded.. Backfill details from base of hole: gravel filter up to 12.00m, bentonite seal up to 5.00m, gravel filter up to 1.00m, bentonite seal up to 0.30m, concrete up to ground level.
Cable Percussion and Rotary CP/RC103
National Grid ENCoordinates
1:25 Ground Level m OD
Levelm OD
SPT N(FI)
Logged by LJ
Logged in accordance with BS5930:1999 + A2:2010
Figure 1 of 4 29/10/2012
BOREHOLE RECORD
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
KEGWORTH WATERMAN TRANSPORT & DEVELOPMENT LTD PC124998
5.30 75.26 Extremely weak reddish brown MUDSTONE. Recovered as angular fine to coarse gravel sized mudstone and
5.50 D siltstone fragments with much soft sandy clay. 5.50- 5.64 4.70 C50/63 [MERCIA MUDSTONE WEATHERING GRADE II]
(4.20)
6.00 74.56
Extremely weak reddish Between 6.00-6.60m, 6.00- 7.50 60 0.15 25 brown SILTSTONE with assumed zone of core
35 0.03 (NR) medium spaced interbedded loss. bands of extremely weak mudstone between20-70mm in thickness. Subhorizontal discontinuities extremely closely to closely spaced
(>25) stepped or undulating Between 6.75-6.80m & dull with some dark 7.40-7.50m, recovered as staining dip 0-45 angular gravel sized degrees. fragments with a little [MERCIA MUDSTONE clay. WEATHERING GRADE II]
7.10- 7.20 C (12)
Between 7.50-7.85m, 7.50- 9.00 77 0.20 40 assumed zone of core
60 0.03 loss. (NR)
7.85 72.71 Very weak to weak light greenish grey SILTSTONE.
Extremely weak to very weak reddish brown MUDSTONE occasionally
8.45- 8.65 C tending to siltstone with 8.45-11.30 PKR rare fine to medium
(10) gravel sized light greenish grey pockets and lenses. Discontinuities extremely closely to closely spaced undulating or stepped and dull with clay smear on Between 9.00-9.25m,
9.00-10.50 83 0.14 16 slight dark grey assumed zone of core 40 0.02 (NR) staining. Dip 0-90 loss.
degrees. 9.25- 9.35 C [MERCIA MUDSTONE Below 9.25m, with
WEATHERING GRADE II] occasional coarse sand (9) to medium gravel sized
open voids.
Between 9.60-9.95m and 11.05-11.80m, with very thinly to thinly interbedded very weak to
(>25) weak light greenish grey siltstone bands between 10-150mm in thickness.
Chiselling: 5.30-5.50m for 60 minutes.
Cable Percussion and Rotary CP/RC103
National Grid ENCoordinates
1:25 Ground Level m OD
Levelm OD
SPT N(FI)
Core RunCore Dia
Depth Cased
TCR/SCR %
Length Max/Min
RQD %
SPT (FI)
Continued by Rotary techniquesGeneral Detail
Logged by LJ
Logged in accordance with BS5930:1999 + A2:2010
Figure 2 of 4 29/10/2012
BOREHOLE RECORDProject
Client
Engineer BoreholeProject No
Drilling Properties/Sampling Strata
Core Run/Depth
ScaleDescription
Depth LegendLengthMax/Min
RQD%TCR/SCR Detail
DescriptionGeneral
Depth Type(Core Dia)
Drilling GroundwaterDepth Technique Crew Depth
of HoleDepthCased
Depth toWater
Date DepthStruck
DepthCased
Rose to DepthSealed
Remarks onGroundwater
Remarks
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
TimeMinsin
DiaHole
%Cased &
(to Water)
Progress
KEGWORTH WATERMAN TRANSPORT & DEVELOPMENT LTD PC124998
Below 10.00m, discontinuities becoming very closely to medium spaced ad subhorizontal.
(14)
10.50-12.00 87 0.15 33 (NR) 71 0.03
Between 12.00-12.15m, 12.00-13.50 90 0.11 7 (NR) assumed zone of core
45 0.01 loss.
(17)
12.50 68.06 Weakly cemented to extremely weak reddish
12.65-12.75 C (14) brown fine grained SANDSTONE. [MERCIA MUDSTONE WEATHERING GRADE II] 12.85 67.71
Extremely weak to weak thinly laminated to very
(>25) thinly interbedded reddish brown MUDSTONE and brown siltstone with occasional light greenish grey siltstone layers
(9) between 5-70mm in thickness. Between 13.50-13.80m,
13.50-15.00 80 0.07 0 Subhorizontal assumed zone of core 33 0.01 (NR) discontinuities extremely loss.
closely to closely spaced undulating on stepped dull with slight polish, occasional clay smear and rare dark grey stain on clay infill up to 10mm in thickness.
(>25) [MERCIA MUDSTONE WEATHERING GRADE II]
Between 14.50-14.70m and 15.00-15.25m, subvertical undulating
(>20) dull discontinuity with dark grey stain.
Cable Percussion and Rotary CP/RC103
National Grid ENCoordinates
1:25 Ground Level m OD
Levelm OD
SPT N(FI)
Logged by LJ
Logged in accordance with BS5930:1999 + A2:2010
Figure 3 of 4 29/10/2012
BOREHOLE RECORDProject
Client
Engineer BoreholeProject No
Drilling Properties/Sampling Strata
Core Run/Depth
ScaleDescription
Depth LegendLengthMax/Min
RQD%TCR/SCR Detail
DescriptionGeneral
Depth Type(Core Dia)
Drilling GroundwaterDepth Technique Crew Depth
of HoleDepthCased
Depth toWater
Date DepthStruck
DepthCased
Rose to DepthSealed
Remarks onGroundwater
Remarks
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
TimeMinsin
DiaHole
%Cased &
(to Water)
Progress
KEGWORTH WATERMAN TRANSPORT & DEVELOPMENT LTD PC124998
G.L. 88.69 0.00- 0.50 B Grass over soft to firm brown slightly sandy
slightly gravelly clay. Gravel is angular to subangular fine to medium siltstone. 0.20 88.49 [TOPSOIL]
Soft to firm sandy slightly gravelly CLAY with occasional rootlets and rare roots up to 3mm in
0.50- 1.20 B diameter. Gravel is angular to subangular fine to 0.50 88.19 medium siltstone. [MERCIA MUDSTONE WEATHERING GRADE IVB]
Soft to firm reddish brown slightly sandy varying to sandy slightly gravelly CLAY with rare subangular fine to medium gravel sized light bluish grey clayey fine sand pockets. Gravel is extremely weak light bluish grey angular fine to coarse siltstone. [MERCIA MUDSTONE WEATHERING GRADE IVA]
1.20- 1.65 B 23 1.20- 1.65 D S6
1.80 D
2.00- 2.45 B 2.00- 2.45 D 1.80 21 S8
(DRY)
2.80 D 2.80 85.89 Stiff becoming very stiff fissured reddish brown slightly mottled light bluish grey slightly sandy
3.00- 3.45 B 17 varying to sandy slightly gravelly CLAY with 3.00- 3.45 D 3.00 S37 frequent angular gravel sized lithorelicts.
(DRY) Fissures are extremely closely to very closely spaced randomly orientated, dull, undulating or stepped. Gravel is angular fine to coarse light bluish grey siltstone. [MERCIA MUDSTONE WEATHERING GRADE III]
3.80 D
4.00- 4.45 B 15 4.00- 4.45 D 4.00 S39
(DRY)
Below 4.80m, fissures with occasional slight dark 4.80 D grey stained surface.
Inspection pit hand excavated to 1.20m depth. A Packer Permeability test was carried out after drilling at a depth of 10.00m on 04/09/2012. Drillhole collapsed from 19.40m to 18.90m prior to rotary coring. A 19mm standpipe piezometer was installed to 18.00m with flush lockable protective cover and a 19mm standpipe piezometer was installed to 12.00m with flush lockable protective cover. Backfill details from base of hole: arisings up to 18.90m, sand filter up to 16.00m, bentonite seal up to 14.00m, sand filter up to 7.00m, bentonite seal up to 0.20m, concrete
Cable Percussion and Rotary CP/RC104
National Grid ENCoordinates
1:25 Ground Level m OD
Levelm OD
SPT N(FI)
Logged by LJ
Logged in accordance with BS5930:1999 + A2:2010
Figure 1 of 4 29/10/2012
BOREHOLE RECORD
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
KEGWORTH WATERMAN TRANSPORT & DEVELOPMENT LTD PC124998
(DRY) 225 to fine grained sandstone. Recovered as angular gravel sized fragments with some firm to stiff gravelly clay. [MERCIA MUDSTONE WEATHERING GRADE II]
7.40 D 7.40 81.29
(NR) Extremely weak to very Between 7.40-8.00m, 7.40- 8.90 60 0.15 10 weak reddish brown, assumed zone of core
26 0.03 occasionally light loss. greenish grey MUDSTONE with medium spaced
8.00-12.30 PKR interbedded very stiff Between 8.00-8.15m and (NI) fissured reddish brown 8.30-8.50m, clay bands
slightly sandy clay bands with extremely closely having frequent angular to closely spaced
(0) fine to coarse gravel randomly orientated dull sized lithorelicts. or slightly polished
(NI) [MERCIA MUDSTONE fissures with rare dark WEATHERING GRADE II] grey stain.
Below 8.50m, weak predominantly light
8.60- 8.70 C greenish grey. (18)
Between 8.90-9.35m, assumed zone of core
8.90-10.40 70 0.10 7 loss. 27 0.03
(NR)
(13)
9.65 79.04 Very stiff to hard Between 9.65-9.68m, reddish brown slightly firm. mottled light greenish grey occasionally
(NI) fissured CLAY with
up to ground level. Chiselling: 6.90-7.40m for 60 minutes.
Cable Percussion and Rotary CP/RC104
National Grid ENCoordinates
1:25 Ground Level m OD
Levelm OD
SPT N(FI)
Core RunCore Dia
Depth Cased
TCR/SCR %
Length Max/Min
RQD %
SPT (FI)
Continued by Rotary techniquesGeneral Detail
Logged by LJ
Logged in accordance with BS5930:1999 + A2:2010
Figure 2 of 4 29/10/2012
BOREHOLE RECORDProject
Client
Engineer BoreholeProject No
Drilling Properties/Sampling Strata
Core Run/Depth
ScaleDescription
Depth LegendLengthMax/Min
RQD%TCR/SCR Detail
DescriptionGeneral
Depth Type(Core Dia)
Drilling GroundwaterDepth Technique Crew Depth
of HoleDepthCased
Depth toWater
Date DepthStruck
DepthCased
Rose to DepthSealed
Remarks onGroundwater
Remarks
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
TimeMinsin
DiaHole
%Cased &
(to Water)
Progress
KEGWORTH WATERMAN TRANSPORT & DEVELOPMENT LTD PC124998
frequent angular fine to Fissures are extremely coarse gravel sized closely to closely lithorelicts. spaced randomly [MERCIA MUDSTONE orientated undulating WEATHERING GRADE III] and dull or with slight 10.30 78.39
(0) polish.
10.40-11.90 67 0.24 25 Extremely weak to very Between 10.30-10.40m and 36 0.03 weak reddish brown 11.25-11.65m, weak.
occasionally light Between 10.40-10.90m, (NR) greenish grey SILTSTONE assumed zone of core
with rare light greenish loss. grey mottling. Incipient discontinuities Between 10.90-11.25m, extremely closely to grading to fine grained medium spaced, undulating sandstone.
(>20) or stepped and dull, dip 0-40 degrees. [MERCIA MUDSTONE WEATHERING GRADE II]
11.40-11.65 C (6)
(NI) Between 11.90-12.20m, assumed zone of core
11.90-13.40 80 0.31 49 loss. 75 0.03 (NR)
Below 12.20m, weak.
(4)
(8)
Between 13.40-13.60m, assumed zone of core
13.40-14.90 87 0.25 65 (NR) loss. 73 0.20
(>20)
(4) Between 14.20-14.25m, 14.25-14.45 C tending to mudstone.
Between 14.65-14.75m, extremely weak tending
(9) to fissured clay.
Between 14.90-15.45m, assumed zone of core
14.90-16.40 63 0.20 29 loss. 47 0.01
Cable Percussion and Rotary CP/RC104
National Grid ENCoordinates
1:25 Ground Level m OD
Levelm OD
SPT N(FI)
Logged by LJ
Logged in accordance with BS5930:1999 + A2:2010
Figure 3 of 4 29/10/2012
BOREHOLE RECORDProject
Client
Engineer BoreholeProject No
Drilling Properties/Sampling Strata
Core Run/Depth
ScaleDescription
Depth LegendLengthMax/Min
RQD%TCR/SCR Detail
DescriptionGeneral
Depth Type(Core Dia)
Drilling GroundwaterDepth Technique Crew Depth
of HoleDepthCased
Depth toWater
Date DepthStruck
DepthCased
Rose to DepthSealed
Remarks onGroundwater
Remarks
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
TimeMinsin
DiaHole
%Cased &
(to Water)
Progress
KEGWORTH WATERMAN TRANSPORT & DEVELOPMENT LTD PC124998
(>20) recovered in parts as angular gravel sized fragments with some to much firm sandy clay.
(7)
16.00 72.69 Extremely weak to very Between 16.00-16.20m, weak reddish brown tending to very stiff
(13) slightly mottled light clay. 16.20-16.30 C greenish grey MUDSTONE
with incipient subhorizontal Between 16.20-16.80m, discontinuities are extremely weak to weak
16.40-17.90 97 0.31 46 extremely closely spaced, very thinly to thinly 78 0.03 randomly orientated interbedded reddish
(12) undulating and dull or brown and light greenish slightly polished grey siltstone band with discontinuity. occasional coarse sand [MERCIA MUDSTONE to fine gravel sized WEATHERING GRADE I] open voids.
(18)
17.10 71.59 Extremely weak to weak Between 17.15-17.40m, reddish brown undulating dull occasionally light bluish discontinuity dip 80-90 grey SILTSTONE with rare degrees. coarse sand to fine
(4) gravel sized open voids. Subhorizontal discontinuities extremely closely to closely spaced, undulating on stepped and dull with rare clay smear. Between 17.90-18.40m, [MERCIA MUDSTONE assumed zone of core
G.L. 75.05 0.00- 0.30 B Grass over firm brown slightly sandy clay with
rootlets and roots up to 1mm in diameter. [MADE GROUND]
0.30 74.75 Stiff becoming fissured reddish brown slightly mottled light bluish grey CLAY with occasional
0.50- 1.20 B subangular fine to medium gravel sized lithorelicts. Fissures are extremely closely to very closely spaced randomly orientated, dull on with slight polish, undulating on stepped. [MERCIA MUDSTONE WEATHERING GRADE IVA] Between 0.50-1.20m and2.50m, fissures with slight staining.
1.20- 1.65 B 20 1.20- 1.65 D S15
1.80 D
2.00- 2.45 U93 1.80 (DRY)
2.50 D 23
Below 2.80m, very stiff, fissures with occasional 2.80 D dark grey staining, fine to coarse gravel sized
Inspection pit hand excavated to 1.20m depth. A 20mm standpipe was installed to 14.70m with a geowrapped slotted section from 1.00m to 14.70m with flush lockable protective cover. Backfill details from base of hole: gravel filter up to 1.00m, bentonite seal up to 0.30m, concrete up to ground level. Chiselling: 6.10-6.60m for 60 minutes.
Cable Percussion and Rotary CP/RC105
National Grid ENCoordinates
1:25 Ground Level m OD
Levelm OD
SPT N(FI)
Logged by LJ
Logged in accordance with BS5930:1999 + A2:2010
Figure 1 of 3 29/10/2012
BOREHOLE RECORD
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
KEGWORTH WATERMAN TRANSPORT & DEVELOPMENT LTD PC124998
(DRY) 6.10 68.95 Extremely weak thickly laminated reddish brown MUDSTONE and light bluish grey siltstone. Recovered as angular fine to coarse clayey gravel sized fragments.
[MERCIA MUDSTONE WEATHERING GRADE III]
6.60- 6.71 1.80 C50/54 (DRY)
7.50 67.55
(NR) Very stiff reddish brown Between 7.50-7.95m, 7.50- 9.00 74 0.11 14 CLAY with extremely weak, assumed zone of core
47 0.01 reddish brown mudstone, loss. and light greenish grey Recovered as disturbed siltstone bands. firm gravelly clay.
Extremely weak to very Subhorizontal weak reddish brown fine discontinuities grained SANDSTONE with extremely closely to frequent becoming closely spaced, occasional light greenish undulating and dull with
(17) grey bands between occasional clay smear. 5-100mm in thickness.
Below 9.55m, with thinly to medium interbedded bands of stiff to very stiff reddish brown slightly mottled light greenish grey clay Between 9.00-9.50m,
9.00-11.50 67 0.08 0 between 50-150mm in assumed zone of core 21 0.01 thickness. loss.
[MERCIA MUDSTONE (NR) WEATHERING GRADE II]
(NI)
(>20)
9.95-10.10 C
Cable Percussion and Rotary CP/RC105
National Grid ENCoordinates
1:25 Ground Level m OD
Levelm OD
SPT N(FI)
Core RunCore Dia
Depth Cased
TCR/SCR %
Length Max/Min
RQD %
SPT (FI)
Continued by Rotary techniquesGeneral Detail
Logged by LJ
Logged in accordance with BS5930:1999 + A2:2010
Figure 2 of 3 29/10/2012
BOREHOLE RECORDProject
Client
Engineer BoreholeProject No
Drilling Properties/Sampling Strata
Core Run/Depth
ScaleDescription
Depth LegendLengthMax/Min
RQD%TCR/SCR Detail
DescriptionGeneral
Depth Type(Core Dia)
Drilling GroundwaterDepth Technique Crew Depth
of HoleDepthCased
Depth toWater
Date DepthStruck
DepthCased
Rose to DepthSealed
Remarks onGroundwater
Remarks
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
TimeMinsin
DiaHole
%Cased &
(to Water)
Progress
KEGWORTH WATERMAN TRANSPORT & DEVELOPMENT LTD PC124998
G.L. 84.91 0.00- 0.50 B Grass over firm brown slightly sandy clay with
rootlets and roots up to 2mm in diameter. [TOPSOIL]
0.50- 1.20 B 0.50 84.41 Stiff reddish brown mottled light bluish grey slightly sandy CLAY with occasional subangular fine to medium gravel sized lithorelicts, root tracks and rare roots up to 2mm in diameter. [MERCIA MUDSTONE WEATHERING GRADE IVB]
1.20 83.71 1.20- 1.65 B Very stiff fissured reddish brown mottled light 1.20- 1.65 C35 bluish grey slightly sandy CLAY with angular to
subangular fine to coarse gravel sized lithorelicts. Fissures are extremely closely to very closely spaced, randomly orientated, undulating, stepped and dull. [MERCIA MUDSTONE WEATHERING GRADE III]
1.80 D
2.00- 2.45 B 2.00- 2.45 1.80 C41
(DRY)
At 2.80m, recovered as coarse gravel sized 2.80 D extremely weak angular light bluish grey mottled
reddish brown siltstone fragments.
3.00- 3.45 B Below 3.00m, becoming hard with frequent angular 3.00- 3.43 1.80 C50/ lithorelicts and occasional dark grey staining to
Inspection pit hand excavated to 1.20m depth. Hole blown out at end of shift 10/09/12. A Packer Permeability test was carried out after drilling at a depth of 15.00-16.00m. A 20mm standpipe was installed to 16.40m with a geowrapped slotted section from 15.00m to 16.50m with flush lockable protective cover. Backfill details from base of hole: collapsed material up to 16.40m, gravel filter up to 8.00m, bentonite seal up to 0.30m, concrete up to ground level. Chiselling: 5.30-5.70m for 60 minutes.
Cable Percussion and Rotary CP/RC106
National Grid ENCoordinates
1:25 Ground Level m OD
Levelm OD
SPT N(FI)
Logged by LJ
Logged in accordance with BS5930:1999 + A2:2010
Figure 1 of 4 29/10/2012
BOREHOLE RECORD
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
KEGWORTH WATERMAN TRANSPORT & DEVELOPMENT LTD PC124998
5.30 79.61 Extremely weak light bluish grey SILTSTONE and extremely weak reddish brown mudstone. [MERCIA MUDSTONE WEATHERING GRADE II]
5.70- 5.82 1.80 C50/56 (DRY)
6.20 78.71
6.20- 7.50 69 0.20 28 (NR) Weakly cemented to Between 6.20-6.60m, 50 0.04 extremely weak reddish assumed zone of core
brown SILTSTONE with loss. thinly to medium interbedded very weak Subhorizontal light greenish grey fine discontinuities very grained sandstone bands closely to closely
6.85- 7.05 C between 10-40mm in spaced dull, undulating thickness and occasional with occasional clay fine sand to medium smear.
(8) gravel sized open voids. [MERCIA MUDSTONE WEATHERING GRADE II]
Between 7.25-7.35m, subvertical undulating dull discontinuity with a little dark grey staining.
7.50- 9.00 80 0.11 14 Between 7.50-7.80m, 23 0.02 (NR) assumed zone of core
loss.
8.00-11.30 PKR (11)
8.35 76.56 Very stiff fissured Fissures are extremely reddish brown slightly to very closely spaced mottled light greenish randomly orientated dull grey slightly sandy CLAY and undulating.
(NI) with occasional subangular to angular fine to coarse lithorelicts. [MERCIA MUDSTONE WEATHERING GRADE III] Between 9.00-9.45m,
9.00-10.50 70 0.20 23 assumed zone of core 39 0.01 loss.
(NR)
(NI)
9.60 75.31 9.65- 9.85 C Very weak to weak reddish
brown SILTSTONE with occasional coarse sand to fine gravel sized open voids.
discontinuities extremely Between 10.10-10.20m, closely to medium spaced weak light greenish grey dull and undulating with fine grained sandstone sandy clay smears. layer. [MERCIA MUDSTONE WEATHERING GRADE II]
Between 11.25-11.35m, very stiff reddish brown sandy clay layer. 11.35 73.56
Weakly cemented to Discontinuities extremely weak reddish extremely closely to brown SILTSTONE. medium spaced undulating
(9) [MERCIA MUDSTONE or stepped, dull with WEATHERING GRADE II] frequent silty smear.
Dip 0-40 degrees.
Between 12.00-12.25m, 12.00-13.50 83 0.16 33 assumed zone of core
52 0.04 (NR) loss.
12.35-12.50 C
(10)
13.30 71.61 (NI) Very stiff reddish brown Between 13.35-13.50m,
slightly mottled light light greenish grey and greenish grey sandy CLAY. fissured. Fissures are
13.50-15.00 90 0.08 (NR) [MERCIA MUDSTONE extremely to very 30 0.02 WEATHERING GRADE III] closely spaced randomly
orientated dull and silty. Between 13.50-13.65m, assumed zone of core
(NI) loss.
14.25 70.66 Extremely weak becoming Subhorizontal very weak reddish brown discontinuities MUDSTONE with occasional extremely closely to light greenish grey closely spaced dull siltstone bands between undulating and silty. 1-20mm in thickness.
(19) [MERCIA MUDSTONE WEATHERING GRADE II]
At 14.95m, undulating dull discontinuity with some dark grey staining.
Cable Percussion and Rotary CP/RC106
National Grid ENCoordinates
1:25 Ground Level m OD
Levelm OD
SPT N(FI)
Logged by LJ
Logged in accordance with BS5930:1999 + A2:2010
Figure 3 of 4 29/10/2012
BOREHOLE RECORDProject
Client
Engineer BoreholeProject No
Drilling Properties/Sampling Strata
Core Run/Depth
ScaleDescription
Depth LegendLengthMax/Min
RQD%TCR/SCR Detail
DescriptionGeneral
Depth Type(Core Dia)
Drilling GroundwaterDepth Technique Crew Depth
of HoleDepthCased
Depth toWater
Date DepthStruck
DepthCased
Rose to DepthSealed
Remarks onGroundwater
Remarks
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
TimeMinsin
DiaHole
%Cased &
(to Water)
Progress
KEGWORTH WATERMAN TRANSPORT & DEVELOPMENT LTD PC124998
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
Note 1 - 24/09/2012 - Unable to monitor - Flooded.
Note 2 - 24/09/2012 - Unable to monitor - Flooded.
FIELDWORK - Water Level MonitoringProject
Client
Project No
Borehole
Instrument (dia. mm)
Depth to Base (m)
Filter Zone
Level
(m)
Depth
(m)Date
KEGWORTHPC124998
Sheet No
Time LevelDepth
(m)Level
Depth
(m)Level
Depth
(m)Level
Depth
(m)Level
Depth
(m)Level
CP/RC105 CP/RC106
S (20mm)
14.70
1.00-14.70
75.05 m OD
S (20mm)
16.40
15.00-16.50
84.91 m OD
ROXHILL DEVELOPMENTS LTD 2
17 Sep 2012 15.27 59.78 12.79 72.12
24 Sep 2012 14.40 60.65 12.13 72.78
1 Oct 2012 14.38 60.67 12.75 72.16
8 Oct 2012 14.35 60.70 15.43 69.48
15 Oct 2012 14.20 60.85 14.50 70.41
22 Oct 2012 14.14 60.91 13.61 71.30
Remarks
Symbols andabbreviations areexplained on theaccompanyingkey sheet.
All dimensionsare in metres.
9
APPENDIX 9
Laboratory Test Results - Geotechnical
Form REP001 Rev 2
DATA SHEET - Laboratory Test Symbols
Classification and Strength
Symbol C - Clay M - Silt (0 - containing organic matter) Plasticity L - Low I - Intermediate H - High V - Very High E - Extremely High Ip Plasticity Index
% % Retained on 425 µm sieve, shown under Ip value
wL Liquid Limit
wP Plastic Limit
NP Non-Plastic
NAT Sample tested in natural state
w Moisture Content
p Particle Density
Test Quick undrained triaxial tests SS Single stage - 102mm diameter.
S3 Single stage - set of 3
38mm diameter.
MS Multistage - 102mm diameter.
D Drained Test
HV Hand Vane
PP Pocket Penetrometer (kg/cm²)
NST Not suitable for test
γb Bulk Density
σ3 Triaxial Cell Pressure
σ1 - σ3 Deviator Stress
## Excessive Strain
cu Undrained Cohesion
c Cohesion Intercept
φ Angle of Shearing Resistance
Linear Linear Shrinkage Shrink
Consolidation
mv Coefficient of Volume Compressibility
cv50 Coefficient of Consolidation - Log t
cv90 Coefficient of Consolidation - √t
Rock
UF Unacceptable Failure
Chemical Analysis
Acid Soluble Total sulphate in specimen, expressed as SO3 %, value in brackets expressed as SO4 %
Water Soluble Soluble sulphate in 2:1 water : soil extract, expressed as SO3 g/l, value in brackets expressed as SO4 g/l
In Water Sulphate content of groundwater, expressed as SO3 g/l, value in brackets expressed as SO4 g/l
pH pH value
Organic content Organic content expressed as a percentage of dry weight
Chloride Chloride Ion content expressed as a percentage of dry weight
MCV, Compaction, CBR
MCV Moisture Condition Value at natural
moisture content
MCC Moisture Condition Calibration
CCV Chalk Crushing Value
Compaction
Type 2.5 = BS 2.5 kg Rammer 4.5 = BS 4.5 kg Rammer V = BS Vibrating Hammer
γb Bulk Density
γd Dry Density
CBR California Bearing Ratio
Type 2.5 = Test on Specimen Recompacted using BS 2.5 kg Rammer 4.5 = As above but using BS 4.5 kg Rammer V = As above but using BS Vibrating Hammer M = Test on open drive mould specimen cut in field S = Soaked Specimen
Top CBR at top of mould
Bottom CBR at bottom of mould
ND None Detected
All tests performed in accordance with BS 1377 : Parts 1-9 : 1990 incorporating amendments where appropriate.
d
LABORATORY RESULTS - Classification and Strength
Project Project No:
Sample
Hole Depth Type Description
Depth)
Sample
PC124998KEGWORTH
Ref
m
(Specimen
Classification Strength
Symbol lp Test γb σ σ −σ cw w w
L p 3 31
Mg/m kN/m3 2
kN/m2
kN/m2
(>425)
c
kN/m2
upd
( )
%
γd
( )(
%%%
Avg
CP/RC10
1
B C682601.20-
1.65
(1.20)
Firm reddish brown slightly sandy
CLAY
CL 14
(0%)
34 20 20
CP/RC10
1
D C674382.00-
2.45
(2.00)
Firm reddish brown fissured slightly
sandy CLAY
15
CP/RC10
1
D C674343.00-
3.45
(3.00)
Firm reddish brown fissured slightly
sandy CLAY
CL 11
(8%)
29 18 12
CP/RC10
1
B C682634.00-
4.45
(4.00)
Very stiff reddish brown fissured
slightly sandy CLAY
16
CP/RC10
1
B C682625.00-
5.45
(5.00)
Very stiff reddish brown slightly sandy
gravelly CLAY. Gravel is angular
mudstone and siltstone
13
CP/RC10
1
B C682646.00-
6.45
(6.00)
Very stiff reddish brown slightly sandy
gravelly CLAY. Gravel is angular
mudstone and siltstone
CL 11
(43%)
29 18 19
CP/RC10
1
D C674336.80
(6.80)
Very stiff reddish brown slightly sandy
gravelly CLAY. Gravel is angular
mudstone and siltstone
16
CP/RC10
2
B C682271.20-
1.65
(1.20)
Very stiff reddish brown fissured
slightly sandy slightly gravelly CLAY.
Gravel is angular fine to coarse
siltstone
CL 13
(21%)
31 18 18
CP/RC10
2
B C682292.00-
2.45
(2.00)
Very stiff reddish brown slightly sandy
slightly gravelly CLAY. Gravel is
angular fine to coarse siltstone
CL 12
(61%)
28 16 14
CP/RC10
3
B C682790.50-
1.20
(0.50)
Firm reddish brown slightly sandy
CLAY
CI 20
(6%)
40 20 17
CP/RC10
3
D C674591.20-
1.65
(1.20)
Stiff brown fissured slightly sandy
CLAY
14
CP/RC10
3
B C682762.00-
2.45
(2.00)
Stiff brown fissured slightly sandy
CLAY
CL 12
(28%)
29 17 16
CP/RC10
3
B C682803.00-
3.45
(3.00)
Very stiff brown fissured slightly sandy
CLAY
17
CP/RC10
3
B C682754.00-
4.45
(4.00)
Very stiff brown fissured slightly sandy
CLAY
21
Remarks Tests performed in accordance with BS 1377: 1990
NST - Not suitable for Test
LABORATORY RESULTS - Classification and Strength
Project Project No:
Sample
Hole Depth Type Description
Depth)
Sample
PC124998KEGWORTH
Ref
m
(Specimen
Classification Strength
Symbol lp Test γb σ σ −σ cw w w
L p 3 31
Mg/m kN/m3 2
kN/m2
kN/m2
(>425)
c
kN/m2
upd
( )
%
γd
( )(
%%%
Avg
CP/RC10
3
B C682775.00-
5.45
(5.00)
Very stiff brown fissured slightly sandy
CLAY
16
CP/RC10
4
B C682311.20-
1.65
(1.20)
Stiff reddish brown sandy CLAY CL 15
(0%)
33 18 23
CP/RC10
4
D C674252.00-
2.45
(2.00)
Stiff reddish brown sandy CLAY 21
CP/RC10
4
B C682303.00-
3.45
(3.00)
Very stiff reddish brown fissured
slightly sandy CLAY
CI 19
(6%)
36 17 17
CP/RC10
4
B C682344.00-
4.45
(4.00)
Very stiff reddish brown fissured
slightly sandy CLAY
15
CP/RC10
4
B C682355.00-
5.45
(5.00)
Very stiff reddish brown fissured
slightly sandy slightly gravelly CLAY.
Gravel is angular fine to coarse
siltstone
CI 16
(9%)
35 19 16
CP/RC10
4
B C682366.00-
6.45
(6.00)
Very stiff reddish brown fissured
slightly sandy slightly gravelly CLAY.
Gravel is angular fine to coarse
siltstone
19
CP/RC10
4
B C682337.00-
7.45
(7.00)
Very stiff reddish brown slightly sandy
slightly gravelly CLAY. Gravel is
angular fine to coarse siltstone
CL 11
(29%)
28 17 20
CP/RC10
5
B C682841.20-
1.65
(1.20)
Stiff reddish brown fissured slightly
sandy CLAY
CH 35
(1%)
59 24 20
CP/RC10
5
D C674732.50
(2.50)
Stiff reddish brown fissured slightly
sandy CLAY
23
CP/RC10
5
D C674723.00-
3.18
(3.00)
Very stiff reddish brown fissured
slightly sandy CLAY
11
CP/RC10
5
B C682894.00-
4.45
(4.00)
Very stiff reddish brown fissured
slightly sandy CLAY
16
CP/RC10
5
B C682865.00-
5.45
(5.00)
Very stiff reddish brown fissured
slightly sandy CLAY
15
CP/RC10
5
B C682856.00-
6.45
(6.00)
Very stiff reddish brown fissured
slightly sandy CLAY
14
Remarks Tests performed in accordance with BS 1377: 1990
NST - Not suitable for Test
LABORATORY RESULTS -
Project:
Project No: PC124998
KEGWORTH
PLOT OF PLASTICITY INDEX AGAINST LIQUID LIMIT
Classification Chart
for all items tested
0
10
20
30
40
50
60
70
80
0 10 20 30 40 50 60 70 80 90 100 110 120 130
Liquid Limit %
Pla
sti
cit
y In
de
x %
Intermediate
CL
CI
CH
CE
CV
ML MI
MH
MV
ME
Low High Very High Extremely High
Remarks 26/09/2012
Soil Type Plasticity Characterisics
C Clay
M Silt
L Low
I Intermediate
H High
V Very High
E Extremely High
Table of Soil Types and Plasticity Characteristics from BS 5930 : 1999
LABORATORY RESULTS - ISRM Suggested Method for Point Load Strength Determination
INVESTIGATION TECHNIQUES INTRODUCTION The following brief review of Ground Investigation techniques, generally used as part of most Site Investigations in the UK, summarises their methodology, advantages and limitations. Detailed descriptions of the techniques are available and can be provided on request. This review should be read in conjunction with the accompanying General Notes. TRIAL PITS The trial pit is amongst the most simple yet effective means of identifying shallow ground conditions on a site. Its advantages include simplicity, speed, potential accuracy and cost-effectiveness. The trial pit is most commonly formed using a backacting excavator which can typically determine ground conditions to some 4 metres below ground level. Hand excavation is often used to locate, expose and detail existing foundations, features or services. In general, it is difficult to extend pits significantly below the water table in predominantly granular soils, where flows can cause instability. Unless otherwise stated, the trial pits will not have been provided with temporary side support during their construction. Under such circumstances ground conditions to some 1.20 metres can be closely inspected, subject to stability assessment, but below this depth, entrance into the pit is not permitted in the absence of shoring and hence observations will have been made from ground surface and samples taken from the excavator bucket. Trends in strata type, level and thickness can be determined, shear surfaces identified and the behaviour of plant, excavation sides and excavated materials can be related to the construction process. They are particularly valuable in land slip investigations. Some types of insitu test can be undertaken in such pits and large disturbed or block samples obtained. CABLE PERCUSSION BORING The light Cable Percussion technique of soft ground boring, typically at a diameter of 150mm, is a well established simple and flexible method of boring vertical holes and generally allows data to be obtained in respect of strata conditions other than rock. A tubular cutter (for cohesive soils) or shell with a flap valve (for granular soils) is repeatedly lifted and dropped using a winch and rope operating from an “A” frame. Soil which enters these tools is regularly removed and either sampled for subsequent examination or test, or laid to one side for backfilling. Steel casing will have been used to prevent collapse of the borehole sides where necessary. A degree of disturbance of soil and mixing of layers is inevitable and the presence of very thin layers of different soils within a particular stratum may not be identified. Changes in strata type can only be detected on recognition of a change in soil samples at surface, after the interface has been passed. For the foregoing reasons, depth measurements should not be considered to be more accurate than 0.10 metre. In cohesive soils cylindrical samples are retrieved by driving or pushing in 100mm nominal diameter tubes. In soft soils, piston sampling or vane testing may be undertaken. In granular soils and often in cohesive materials, insitu Standard Penetration Tests (SPT’s) are performed. The SPT records the number of standard blows required to drive a 50mm diameter open or cone ended probe for 300mm after an initial 150mm penetration. A modified method of recording is used in more dense strata. Small disturbed samples are obtained throughout. The technique can determine ground conditions to depths in excess of 30 metres under suitable circumstances and usually causes less surface disturbance than trial pitting. ROTARY DRILLING Rotary Drilling to produce cores by rotating an annular diamond-impregnated tube or barrel into the ground is the technique most appropriate to the forming of site investigation boreholes through rock or other hard strata. It has the advantage of being able to be used vertically or at an angle. Core diameters of less than 100mm are most common for site investigation purposes. Core is normally retrieved in plastic lining tubes. A flushing fluid such as air, water or foam is used to cool the bit and carry cuttings to the surface. Examination of cores allows detailed rock description and generally enables angled discontinuity surfaces to be observed. However, vertical holes do not necessarily reveal the presence of vertical or near-vertical fissures or joint discontinuities. The core type and/or techniques used. Where open hole rotary drilling is employed, descriptions of strata result from examination at surface of small particles ejected from the borehole in the flushing medium. In consequence, no indication of fissuring, bedding, consistency or degree of weathering can be obtained. Small scale plant can be used for auger drilling to limited depths where access is constrained. Depths in excess of 60 metres can be achieved under suitable circumstances using rotary techniques, with minimal surface disturbance.
WINDOW SAMPLING This technique involves the driving of an open-ended tube into the ground and retrieval of the soil which enters the tube. The term “window sample” arose from the original device which had a “window” or slot cut into the side of the tube through which samples were taken. This has now been superseded by the use of a thin-walled plastic liner within a sampler which has a solid wall. Diameters range from 36 to 86mm. Such samples can be used for qualitative logging, selection of samples for classification and chemical analysis and for obtaining a rudimentary assessment of strength. Driving devices can be hand-held or machine mounted and the drive tubes are typically in 1m lengths. The hole formed is not cased, however, and hence the success of this technique is limited when soils and groundwater conditions are such that the sides of the hole collapse on withdrawal of the sampler. Obstructions within the ground, the density of the material or its strength can also limit the depth and rate of penetration of this light-weight investigation technique. Nevertheless, it is a valuable tool where access is constrained such as within buildings or on embankments. Depths of up to 8m can be achieved in suitable circumstances but depths of 4m to 6m are more common. EXPLORATORY HOLE RECORDS The data obtained by these techniques are generally presented on Trial Pit, Borehole, Drillhole or Window Sample Records. The descriptions of strata result from information gathered from a number of sources which may include published geological data, preliminary field observations and descriptions, insitu test results, laboratory test results and specimen descriptions. A key to the symbols and abbreviations used accompanies the records. The descriptions on the exploratory hole records accommodate but may not necessarily be identical to those on any preliminary records or the laboratory summaries. The records show ground conditions at the exploratory hole locations. The degree to which they can be used to represent conditions between or beyond such holes, however, is a matter for geological interpretation rather than factual reporting and the associated uncertainties must be recognised. DYNAMIC PROBING This technique typically measures the number of blows of a standard weight falling over a standard height to advance a cone-ended rod over sequential standard distances (typically 100mm). Some devices measure the penetration of the probe per standard blow. It is essentially a profiling tool and is best used in conjunction with other investigation techniques where site-specific correlation can be used to delineate the distribution of soft or loose soils or the upper horizon of a dense or strong layer such as rock. Both machine-driven and hand-driven equipment is available, the selection depending upon access restrictions and the depth of penetration required. It is particularly useful where access for larger equipment is not available, disturbance is to be minimised or where there are cost constraints. No samples are recovered and some techniques leave a sacrificial cone head in the ground. As with other lightweight techniques, progress is limited in strong or dense soils. The results are presented both numerically and graphically. Depths of up to 10m are commonly achieved in suitable circumstances. The hand-driven DCP probing device has been calibrated by the TRL to provide a profile of CBR values over a range of depths of up to 1.50m. INSTRUMENTATION The most common form of instrument used in site investigation is either the standpipe or else the standpipe piezometer which can be installed in investigation holes. They are used to facilitate monitoring of groundwater levels and water sampling over a period of time following site work. Normally a standpipe would be formed using rigid plastic tubing which has been perforated or slotted over much of its length whilst a standpipe piezometer would have a filter tip which would be placed at a selected level and the hole sealed above and sometimes below to isolate the zone of interest. Groundwater levels are determined using an electronic “dipmeter” to measure the depth to the water surface from ground level. Piezometers can also be used to measure permeability. They are simple and inexpensive instruments for long term monitoring but response times can limit their use in tidal areas and access to the ground surface at each instrument is necessary. Remote reading requires more sophisticated hydraulic, electronic or pneumatic equipment. Settlement can be monitored using surface or buried target plates whilst lateral movement over a range of depths is monitored using slip indicator or inclinometer equipment.
GENERAL NOTES 1. The report is prepared for the exclusive use of the Client named in the
document and copyright subsists with Geotechnics Limited. Prior written
permission must be obtained to reproduce all or part of the report. It is
prepared on the understanding that its contents are only disclosed to
parties directly involved in the current investigation, preparation and
development of the site.
2. Further copies may be obtained with the Client's written permission,
from Geotechnics Limited with whom the master copy of the document
will be retained.
3. The report and/or opinion is prepared for the specific purpose stated in
the document and in relation to the nature and extent of proposals
made available to Geotechnics Limited at that time. Re-consideration
will be necessary should those details change. The recommendations
should not be used for other schemes on or adjacent to the site without
further reference to Geotechnics Limited.
4. The assessment of the significance of the factual data, where called for,
is provided to assist the Client and his Engineer and/or Advisers in the
preparation of their designs.
5. The report is based on the ground conditions encountered in the
exploratory holes together with the results of field and laboratory testing
in the context of the proposed development. The data from any
commissioned desk study and site reconnaissance are also drawn upon.
There may be special conditions appertaining to the site, however, which
are not revealed by the investigation and which may not be taken into
account in the report.
6. Methods of construction and/or design other than those proposed by the
designers or referred to in the report may require consideration during
the evolution of the proposals and further assessment of the
geotechnical and any geoenvironmental data would be required to
provide discussion and evaluations appropriate to these methods.
7. The accuracy of results reported depends upon the technique of
measurement, investigation and test used and these values should not be
regarded necessarily as characteristics of the strata as a whole (see
accompanying notes on Investigation Techniques). Where such
measurements are critical, the technique of investigation will need to be
reviewed and supplementary investigation undertaken in accordance
with the advice of the Company where necessary.
8. The samples selected for laboratory test are prepared and tested in
accordance with the relevant Clauses of BS 1377 Parts 1 to 8, where
appropriate, in Geotechnics Limited’s UKAS accredited Laboratory,
where possible. A list of tests is given.
9. Tests requiring the use of another laboratory having UKAS accreditation
where possible are identified.
10. Any unavoidable variations from specified procedures are identified in
the report.
11. Specimens are cut vertically, where this is relevant and can be identified,
unless otherwise stated.
12. All the data required by the test procedures are recorded on
individual test sheets but the results in the report are presented in
summary form to aid understanding and assimilation for design
purposes. Where all details are required, these can be made
available.
13. Whilst the report may express an opinion on possible
configurations of strata between or beyond exploratory holes, or on
the possible presence of features based on either visual, verbal,
written, cartographical, photographic or published evidence, this is
for guidance only and no liability can be accepted for its accuracy.
14. Classification of materials as Made Ground is based on the
inspection of retrieved samples or exposed excavations. Where it is obvious that foreign matter such as paper, plastic or metal is present, classification is clear. Frequently, however, for fill materials that arise from the adjacent ground or from the backfilling of excavations, their visual characteristics can closely resemble those of undisturbed ground. Other evidence such as site history, exploratory hole location or other tests may need to be drawn upon to provide clarification. For these reasons, classification of soils on the exploratory hole records as either Made Ground or naturally occurring strata, the boundary between them and any interpretation that this gives rise to should be regarded as provisional and subject to re-evaluation in the light of further data.
15. The classification of materials as Topsoil is generally based on
visual description and should not be interpreted to mean that the material so described complies with the criteria for Topsoil used in BS 3882 (2007). Specific testing would be necessary where such definition is a requirement.
16. Ground conditions should be monitored during the construction of
the works and the report should be re-evaluated in the light of
these data by the supervising geotechnical engineers.
17. Any comments on groundwater conditions are based on
observations made at the time of the investigation, unless specifically stated otherwise. It should be noted, however, that the observations are subject to the method and speed of boring, drilling or excavation and that groundwater levels will vary due to seasonal or other effects.
18. Any bearing capacities for conventional spread foundations which
are given in the report and interpreted from the investigation are for bases at a minimum depth of 1m below finished ground level in naturally occurring strata and at broadly similar levels throughout individual structures, unless otherwise stated. The foundations should be designed in accordance with the good practice embodied in BS 8004:1986 - Foundations, supplemented for housing by NHBC Standards. Foundation design is an iterative process and bearing pressures may need adjustment or other measures may need to be taken in the context of final layouts and levels prior to finalisation of proposals.
19. Unless specifically stated, the investigation does not take account
of the possible effects of mineral extraction or of gases from fill or
natural sources within, below or outside the site.
20. The costs or economic viability of the proposals referred to in the
report, or of the solutions put forward to any problems
encountered, will depend on very many factors in addition to
geotechnical or geoenvironmental considerations and hence their