Top Banner
IN THE WORLD OF PARTICLES PAMAS COUNTS PAMAS PMA Particle measuring and analysing software REV 09/2018 Application: Software for the operation of particle counters and for the analysis of measurement results Software features: Main functions: Software for operation, for parameter setting, for data storage and for the analysis of measurement results Output of measuring results: numerical and graphical report of cumulative and differential particle counts in compliance with the cleanliness standards ISO 4406, NAS 1638, SAE AS 4059, GJB 420, GOST 17216 and NAVAIR 01-1A-17 User interface in English, German, French, Spanish, Portuguese, Chinese, Russian and Finnish. Standard delivery in English plus country specific delivery in the national language of the user‘s home country (if available). Additional function: Size distribution analysis Microsoft Windows ® 7, 8 and 10. Compatibility is tested and confirmed Software for the operation of particle counters and for theanalysis of measuring results
2

PAMAS PMA Particle measuring and analysing software...with the cleanliness standards ISO 4406, NAS 1638, SAE AS 4059, GJB 420, GOST 17216 and NAVAIR 01-1A-17 User interface in English,

Aug 11, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: PAMAS PMA Particle measuring and analysing software...with the cleanliness standards ISO 4406, NAS 1638, SAE AS 4059, GJB 420, GOST 17216 and NAVAIR 01-1A-17 User interface in English,

In the world of partIcles pamas counts

PAMAS PMAParticle measuring and analysing software

REV 09/2018

Application:

Software for the operation of particle counters and for the analysis of measurement results

Software features:

� Main functions: Software for operation, for parameter setting, for data storage and for the analysis of measurement results

� Output of measuring results: numerical and graphical report of cumulative and differential particle counts in compliance with the cleanliness standards ISO 4406, NAS 1638, SAE AS 4059, GJB 420, GOST 17216 and NAVAIR 01-1A-17

� User interface in English, German, French, Spanish, Portuguese, Chinese, Russian and Finnish. Standard delivery in English plus country specific delivery in the national language of the user‘s home country (if available).

� Additional function: Size distribution analysis

� Microsoft Windows® 7, 8 and 10. Compatibility is tested and confirmed

Software for the operation of particle counters and for theanalysis of measuring results

Page 2: PAMAS PMA Particle measuring and analysing software...with the cleanliness standards ISO 4406, NAS 1638, SAE AS 4059, GJB 420, GOST 17216 and NAVAIR 01-1A-17 User interface in English,

PAMAS HEAD OFFICE Dieselstraße 10, D-71277 Rutesheim, Phone: +49 7152 99 63 0, Fax: +49 7152 99 63-32, Email: [email protected] USA 1408 South Denver Avenue, Tulsa, OK 74119 USA, Phone: +1 918 743 6762, Fax: +1 918 743 6917, Email: [email protected] BEnElUx Mechelen Campus, Schaliënhoevedreef 20T, B-2800 Mechelen, Phone: +32 15 28 20 10, Mobile: +32 477 42 48 62, Email: [email protected] FrAnCE Route du Tailleur 210/136, F-40170 Saint-Julien-en-Born, Mobile +33 6 25 33 20 41, Email: [email protected] PAMAS lATIn AMErICA Curitiba-Paraná, Brazil, Phone/Fax: +55 41 3022 5445, Mobile: +55 41 999 72 21 73, Email: [email protected] InDIA No. 203, I floor, Oxford House, #15 Rustam Bagh Main Road, Bangalore 560017, India, Phone: +91 80 41 15 00 39, Email: [email protected] HISPAnIA Calle Zubilleta No. 13 1°B, ES-48991 Algorta, Mobile: +34 67 75 39 699, Email: [email protected] PAMAS UK Sci-Tech Daresbury, Keckwick Lane, Daresbury, Cheshire WA4 4FS, Mobile: +44 79 17 71 33 66, Email: [email protected]

® R

egis

tere

d tr

adem

arks

are

pro

pert

ies

of t

heir

indi

vidu

al o

wne

rs. A

ll sp

ecifi

catio

ns a

re s

ubje

ct t

o ch

ange

with

out

notic

e.

P l e a s e v i s i t o u r w e b s i t e a t w w w . p a m a s . d e

PAMAS PMAremote control and data management of measuring results The software PAMAS PMA helps to perform particle measurements and it makes the results visible in tables and graphs. The following particle counters can be operated by the programme: � PAMAS SVSS � PAMAS SBSS � PAMAS SBSS WG � PAMAS S40 � PAMAS S40 GO � PAMAS S40 AVTUR � PAMAS S40 GO AVTUR � PAMAS S4031 � PAMAS S4031 WG � PAMAS S4031 GO � PAMAS S4031 GO WG

The particle numbers and the classified particle size distribution are reported in

The software PAMAS PMA shows particle measuring results in tables and graphs. The results are classified in size channels. The number of displayed size channels can be defined by the operator in the software settings (screenshot: PAMAS).

The software PAMAS PMA may also be used for size distribution analysis and shows the size distribution as defined by the user in relation to population, area or volume (see in this picture). (screenshot: PAMAS)

The PAMAS PMA printout of measuring results shows the cumulative and differential particle numbers in tables and graphs. The software also reports the cleanliness class in compliance with international cleanliness standards including ISO 4406, NAS 1638 and SAE AS 4059 (picture: PAMAS).

At the beginning of each new measurement, the operator can define the dilution factor in the software settings. The PAMAS PMA pro-gramme considers this factor during analysis and calculates the particle concentration of the originally undiluted sample. (screenshot: PAMAS)

PMA-Particle Measuring and Analysing Software

Measurement file : C:\PMA23\20101210154006.mesSample ID : Sample 1Customer : CustomerSampling location : Sampling date : measured at : 10.12.2010User : SBCounter : ID: SYS-3516 v5.2 S#: R35-02E7CB110000Sensor : HCB-LD-25/25Comment :

Print : Average values of measurement(s) 1, 2, 3

Measured volume : 10.0 mlAnalysed Volume : 100 mlDilution Factor : -

ISO 4406 : 15/12/6 NAS 1638 : 4 (4, 0, 00, 00, 00) SAE 749D : 0

22.08.2011

Diameters cumulative> 1.00 µm 160227> 2.00 µm 17787> 3.00 µm 8633> 4.00 µm 5007> 5.00 µm 2460> 7.00 µm 840

> 10.00 µm 243> 15.00 µm 37> 20.00 µm 0> 25.00 µm 0> 30.00 µm 0> 40.00 µm 0> 50.00 µm 0> 60.00 µm 0> 80.00 µm 0

> 100.00 µm 0

Particles lin. cum.

Particle size [µm]

1.002.00

3.004.00

5.007.00

10.0015.00

20.0025.00

30.0040.00

50.0060.00

80.00100.00

1e+05

0

Diameters differential1.00 - 2.00 µm 1424402.00 - 3.00 µm 91533.00 - 4.00 µm 36274.00 - 5.00 µm 25475.00 - 7.00 µm 1620

7.00 - 10.00 µm 59710.00 - 15.00 µm 20715.00 - 20.00 µm 3720.00 - 25.00 µm 025.00 - 30.00 µm 030.00 - 40.00 µm 040.00 - 50.00 µm 050.00 - 60.00 µm 060.00 - 80.00 µm 0

80.00 - 100.00 µm 0> 100.00 µm 0

Particles lin. diff.

Particle size [µm]

1.002.00

3.004.00

5.007.00

10.0015.00

20.0025.00

30.0040.00

50.0060.00

80.00100.00

1e+05

0

compliance with international cleanliness standards (e.g. with ISO 4406, SAE AS 4059, NAS 1638, GOST 17216, GJB 420 and NA-VAIR 01-1A-17). The measuring report inclu-des all sample parameters and the numerical and graphical presentation of the measuring results. The results are automatically stored and may be printed and exported into CSV files. Historical results of former measure-ments can also be uploaded, printed and exported. The measuring results may be con-verted line by line into ASCII format, so that they could be used e.g. in a LIMS system.

Software compatibility to common operating systemsThe software PAMAS PMA is compatible with the Microsoft operating systems Windows® 7, 8 and 10.