Implant Removal Kit
4

Ordering Information for Implant Removal Kit

Jan 01, 2017

Download

Documents

vuthuan
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Ordering Information for Implant Removal Kit

Distributed by:

Manufactured by:

For More Information, Please Contact Your Local BIOMET 3i Sales Representative.www.biomet3i.com

JoinUs

FollowUs

WatchUs

DownloadIt

Global Headquarters4555 Riverside DrivePalm Beach Gardens, FL 334101-800-342-5454Outside the U.S.: +1-561-776-6700Fax: +1-561-776-1272www.biomet3i.com

BIOMET 3iDental Iberica S.L.WTC Almeda Park, Ed. 1, Planta 1ªPl. de la Pau, s/n08940, Cornellà de Llobregat(Barcelona) SpainPhone: +34-93-470-55-00Fax: +34-93-371-78-49

EC REP Dongbang AcuPrime 1 Forrest Units, Hennock Road East, Marsh Barton, Exeter EX2 8RU, UKTel : +44 1392-829500

INST1245REV A 04/14

Implant Removal KitOrdering Information for Implant Removal Kit (FRKIT)

Description Product Name

RatchetTorque Control Device

FRCHTTW 80400

Torque Indicating Ratchet Wrench Fixture Remover

FixtureSize

Length(mm)

Fixture Remover(Product Name)

Narrow3.5

15.020.0

FR 315FR 320

Regular3.54.0

15.020.0

FR 315 / FR 415

Wide5.0

15.020.0

FR 415 / FR 515

Wide6-8

15.020.0

FR 515 / FR 615

FR 320 / FR 420

FR 420 / FR 520

FR 520 / FR 620

E-space #103, 104-1, 104-2, 105, 106, 205, 212, 312, 509, 510, 511,10F, 36, 27Gil, Digital-ro, Guro-gu, SEOUL, 152-789, Rep. of Korea Tel.: 82-2-582-2885 | Fax: 82-2-582-2883 | www.neobiotech.co.kr

Astra Tech is a trademark of Dentsply. Dentsply is a trademark of Dentsply IH. BIOMET 3i is a trademark of BIOMET 3i, LLC. NeoBiotech is a trademark of NEOBIOTECH CO., LTD. Nobel Biocare is a trademark of Nobel Biocare Services AG. Straumann is a trademark of Straumann Holding AG. Zimmer Dental is a trademark of Zimmer Holdings Inc. ©2014 BIOMET 3i LLC.

This material is intended for clinicians only and is NOT intended for patient distribution. This material is not to be redistributed, duplicated, or disclosed without the express written consent of BIOMET 3i. For additional product information, including indications, contraindications, warnings, precautions, and potential adverse effects, see the product package insert and the BIOMET 3i Website.

Hexed Screw Driver

Length (mm) Product Name7.012.017.0

HDF 1607HDF 1612HDF 1617

Screw sizeM 1.4 M 1.54M 1.6M 1.8No 1-72 UNFM 2.0M 2.5

Product NameFRS 14FRS 154FRS 16FRS 18FRS 172FRS 20FRS 25

(not included in kit)

Fixture Remover Screw

0120

Page 2: Ordering Information for Implant Removal Kit

“A myriad of reasons exist for the removal of an osseointegrated implant. Infection, bone loss and aesthetic challenges are just a few. Traditional approaches typically require the removal of significant amounts of bone, leaving the site unsuitable for immediate replacement. The Implant Removal Kit has exceeded my expectations and is a must have instrument of choice when removing implants! It helps to make removal of the implant a less involved procedure.”*

Fixture Remover Kit includes four diameters: Ø3.5, Ø4, Ø5, Ø6with two lengths: 15mm, 20mm

Hex Driver Kit includes three lengths:7mm, 12mm, 17mm

Fixture Remover Screws Kit includes six diameters (2 of each): M1.4, M1.6, M1.8, No 1-72UNF, M2.0, M2.5

Torque Indicating Ratchet WrenchKit includes one Torque Wrench (assembly required)

Ratchet Arm Torque Indicator Body Spring Loaded Indicator Pin

AB

C

The prevalence of implants experiencing peri-implantitis has been reported in excess of 12%.1, 2 A case of peri-implantitis presents a surgical dilemma for the clinician – trephine the implant, but sacrifice valuable native bone.

Peri-implantitis

Clinical ChallengesWith Failed Implants

Tool Kit Designed To Remove Multiple Implant Systems

Tray Components

explant

1. Fransson C, Lekholm U, Jemt T, Berglundh T. Prevalence of subjects with progressive bone loss at implants. Clinical Oral Implants Research. 2005;16:440–446.

2. Zitzmann NU, Berglundh T. Definition and prevalence of peri-implant diseases. J Clin Perio. 2008;35:286–291.

Harold S. Baumgarten, DMD - Amsterdam Dental Group, Philadelphia, PA, Clinical Professor, University of Pennsylvania, Department of Periodontics.

*Dr. Baumgarten has a financial relationship with BIOMET 3i LLC resulting from speaking engagements, consulting engagements and other retained services.

• Effective instrumentation for atraumatic removal of failed implants

• Eliminates the use of trephine drills and thereby minimizes bone trauma

• Compatible with most implant systems

- Nobel Biocare®

- Straumann®

- Astra Tech™

- Dentsply

- Zimmer Dental™

- BIOMET 3i™

- For other implant systems, go to: www.ImplantCompatibility.biomet3i.com

Page 3: Ordering Information for Implant Removal Kit

“A myriad of reasons exist for the removal of an osseointegrated implant. Infection, bone loss and aesthetic challenges are just a few. Traditional approaches typically require the removal of significant amounts of bone, leaving the site unsuitable for immediate replacement. The Implant Removal Kit has exceeded my expectations and is a must have instrument of choice when removing implants! It helps to make removal of the implant a less involved procedure.”*

Fixture Remover Kit includes four diameters: Ø3.5, Ø4, Ø5, Ø6with two lengths: 15mm, 20mm

Hex Driver Kit includes three lengths:7mm, 12mm, 17mm

Fixture Remover Screws Kit includes six diameters (2 of each): M1.4, M1.6, M1.8, No 1-72UNF, M2.0, M2.5

Torque Indicating Ratchet WrenchKit includes one Torque Wrench (assembly required)

Ratchet Arm Torque Indicator Body Spring Loaded Indicator Pin

AB

C

The prevalence of implants experiencing peri-implantitis has been reported in excess of 12%.1, 2 A case of peri-implantitis presents a surgical dilemma for the clinician – trephine the implant, but sacrifice valuable native bone.

Peri-implantitis

Clinical ChallengesWith Failed Implants

Tool Kit Designed To Remove Multiple Implant Systems

Tray Components

explant

1. Fransson C, Lekholm U, Jemt T, Berglundh T. Prevalence of subjects with progressive bone loss at implants. Clinical Oral Implants Research. 2005;16:440–446.

2. Zitzmann NU, Berglundh T. Definition and prevalence of peri-implant diseases. J Clin Perio. 2008;35:286–291.

Harold S. Baumgarten, DMD - Amsterdam Dental Group, Philadelphia, PA, Clinical Professor, University of Pennsylvania, Department of Periodontics.

*Dr. Baumgarten has a financial relationship with BIOMET 3i LLC resulting from speaking engagements, consulting engagements and other retained services.

• Effective instrumentation for atraumatic removal of failed implants

• Eliminates the use of trephine drills and thereby minimizes bone trauma

• Compatible with most implant systems

- Nobel Biocare®

- Straumann®

- Astra Tech™

- Dentsply

- Zimmer Dental™

- BIOMET 3i™

- For other implant systems, go to: www.ImplantCompatibility.biomet3i.com

Page 4: Ordering Information for Implant Removal Kit

Distributed by:

Manufactured by:

For More Information, Please Contact Your Local BIOMET 3i Sales Representative.www.biomet3i.com

JoinUs

FollowUs

WatchUs

DownloadIt

Global Headquarters4555 Riverside DrivePalm Beach Gardens, FL 334101-800-342-5454Outside the U.S.: +1-561-776-6700Fax: +1-561-776-1272www.biomet3i.com

BIOMET 3iDental Iberica S.L.WTC Almeda Park, Ed. 1, Planta 1ªPl. de la Pau, s/n08940, Cornellà de Llobregat(Barcelona) SpainPhone: +34-93-470-55-00Fax: +34-93-371-78-49

EC REP Dongbang AcuPrime 1 Forrest Units, Hennock Road East, Marsh Barton, Exeter EX2 8RU, UKTel : +44 1392-829500

INST1245REV A 04/14

Implant Removal KitOrdering Information for Implant Removal Kit (FRKIT)

Description Product Name

RatchetTorque Control Device

FRCHTTW 80400

Torque Indicating Ratchet Wrench Fixture Remover

FixtureSize

Length(mm)

Fixture Remover(Product Name)

Narrow3.5

15.020.0

FR 315FR 320

Regular3.54.0

15.020.0

FR 315 / FR 415

Wide5.0

15.020.0

FR 415 / FR 515

Wide6-8

15.020.0

FR 515 / FR 615

FR 320 / FR 420

FR 420 / FR 520

FR 520 / FR 620

E-space #103, 104-1, 104-2, 105, 106, 205, 212, 312, 509, 510, 511,10F, 36, 27Gil, Digital-ro, Guro-gu, SEOUL, 152-789, Rep. of Korea Tel.: 82-2-582-2885 | Fax: 82-2-582-2883 | www.neobiotech.co.kr

Astra Tech is a trademark of Dentsply. Dentsply is a trademark of Dentsply IH. BIOMET 3i is a trademark of BIOMET 3i, LLC. NeoBiotech is a trademark of NEOBIOTECH CO., LTD. Nobel Biocare is a trademark of Nobel Biocare Services AG. Straumann is a trademark of Straumann Holding AG. Zimmer Dental is a trademark of Zimmer Holdings Inc. ©2014 BIOMET 3i LLC.

This material is intended for clinicians only and is NOT intended for patient distribution. This material is not to be redistributed, duplicated, or disclosed without the express written consent of BIOMET 3i. For additional product information, including indications, contraindications, warnings, precautions, and potential adverse effects, see the product package insert and the BIOMET 3i Website.

Hexed Screw Driver

Length (mm) Product Name7.012.017.0

HDF 1607HDF 1612HDF 1617

Screw sizeM 1.4 M 1.54M 1.6M 1.8No 1-72 UNFM 2.0M 2.5

Product NameFRS 14FRS 154FRS 16FRS 18FRS 172FRS 20FRS 25

(not included in kit)

Fixture Remover Screw

0120