SNW Type Series Booklet 1481.5/4--10 SNW Rev.4, 15.05.2002 Applications Irrigation and drainage pumping stations, stormwater pumping stations, raw and clean water pumps in water works, cooling water pumps in power stations and industry, industrial water supply and flood control. Dock-- and sluice pumps. Operating data Capacities Q up to 2,4 m 3 /s Total heads H up to 50 m Pump sizes DN 400 up to 700 Temperature of liquid handled max. 60 o C Design Single stage vertical tubular casing pump with semi axial impeller, submerged hydraulic assembly, discharge nozzle above or below floor, welded riser pipes, non-withdrawable rotating assembly. Bearings and lubrication Shafts supported in medium-lubricated, highly wear-resistant ResidurR bea- rings, grease-lubricated anti--friction bearing in the drive stand to compensate rotor weight and axial thrust. Shaft sealing Packed gland at discharge nozzle above floor, ResidurR plain bearing working as throttle bush at discharge nozzle below floor. Program classification / materials Standard program Custom made program Material combinations 01 02 03 04 05 Inlet Nozzle GG--20 (GJL 200) Ni Resist 1.4517 / Diffuser GG--20 (GJL 200) Ni Resist 1.4462 Discharge elbow GG--20 (GJL 200) Ni Resist Riser pipe RSt 37-2 (S235JRG2) 316L 1.4462 Motor stool RSt 37-2 (S235JRG2) Shafts C 45 SH+S / C45N 1.4021.05 1.4462 Impeller, open G--CuSn10 1.4408 1.4409 1.4517 Impeller , closed 1.4408 1.4409 1.4517 Designation Series Semi axial impeller DN discharge nozzle Impeller diameter (mm) Material combination SNW M 500-- 505 EBn Installation Type 01 Tubular casing pumps
80
Embed
Operating data - cometegy.com series booklet.pdf · Type Series Booklet SNW 1481.5/4--10 SNW Rev.4, 15.05.2002 Applications Irrigation and drainage pumping stations, stormwater pumping
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
SNWType Series Booklet1481.5/4--10
SNW
Rev.4, 15.05.2002
ApplicationsIrrigation and drainage pumping stations, stormwater pumping stations, rawand clean water pumps in water works, cooling water pumps in power stationsand industry, industrial water supply and flood control. Dock-- and sluicepumps.
Operating dataCapacities Q up to 2,4 m3/sTotal heads H up to 50 mPump sizes DN 400 up to 700Temperature of liquid handled max. 60 oC
Bearings and lubricationShafts supported in medium-lubricated, highly wear-resistant ResidurR bea-rings, grease-lubricated anti--friction bearing in the drive stand to compensaterotor weight and axial thrust.
Shaft sealingPacked gland at discharge nozzle above floor, ResidurR plain bearing workingas throttle bush at discharge nozzle below floor.
Program classification / materials
Standardprogram
Custom madeprogram
Material combinations
01 02 03 04 05
Inlet Nozzle GG--20 (GJL 200) Ni Resist 1.4517 /
Diffuser GG--20 (GJL 200) Ni Resist 1.4462
Discharge elbow GG--20 (GJL 200) Ni Resist
Riser pipe RSt 37-2 (S235JRG2) 316L 1.4462
Motor stool RSt 37-2 (S235JRG2)
Shafts C 45SH+S/ C45N
1.4021.05 1.4462
Impeller, open G--CuSn10 1.4408 1.4409 1.4517
Impeller , closed 1.4408 1.4409 1.4517
Designation
SeriesSemi axial impeller
DN discharge nozzleImpeller diameter (mm)
Material combination
SNW M 500 -- 505 EBn
Installation Type
01
Tubular casing pumps
SNWType Series Booklet
2 SNWRev.4, 15.05.2002
Table of Contents
Contents Page
Acceptance Testing Inspection and Testing 10Accessories 10Applications 1
Bearing Arrangements 19 and 20Bearings Shaft Guide Bearings 10
Bearings Thrust Bearing 10Bearing sizes Technical Data 23 to 74Bottom Clearance Selection Guide 4
Capacity Performance Curves 21 to 73Casing Design 1
Sectional Drawings 76 to 78Selection Charts 3Selection Guide 4 to 9Shaft Guide Bearings 10Shafts 10
Shaft Sealing 10Shaft Protecting Sleeves 10Shaft Couplings Shafts 10Spare Parts Recommended List of Spares 74Speeds Performance Curves 21 to 73Starting Torque Selection Guide 4 to 9
Start--up Mode Drive 10Strainer Clear Passage 10Strainer Size List of Liquids Handled 3Submergence Depth (ET) Dimensions 23 to 74
Temperatures Operating Limits 10
Testing Inspection and Testing 10Test Pressure Operating Limits 10
Wet--well installation Mounting Arrangements 10
600--700n=880
600--720n=880
600--700n= 980 600--720
n= 980
SNWType Series Booklet
3SNWRev.4, 15.05.2002
List of Liquids HandledSelection of material combinations depending on liquid handled
Liquids handled 1) Indications / RecommendationsClean or potable water No pre--cleaning requiredDirty waterRiver waterStorm water Pre--cleaning by screen, overflow or baffleRaw water 4)
Pre cleaning by screen, overflow or baffle
Combined water and sewageDistance between screen bars (mm) Overflow and baffle
Sewage with low dilution Q ≤ 2 m3/s ≤ 15 mm noSewage with low dilution Q ≥ 2 m3/s ≤ 20 mm no
-- abrasive matters Material combination 02 3) -- 0.2 g/l max. solid contentIndustrial effluent, slightly acidic (pH--value ≥ 6) Material combination 02 3) -- plus special coating
1) Liquids not mentioned here require in most cases upgraded material. Please consult.2) to be applied in case of increased contamination of the liquid handled3) Standard variant (page 11) to be ordered separately4) by raw water please send a water analysis to KSB
Selection chart 50 Hz Selection chart 60 Hz
SNWType Series Booklet
4 SNWRev.4, 15.05.2002
Selection GuideThe data in the boxes is essential for pump sizing.A computerized quote can be supplied at short notice in response to the telefax enquiry.
Determination of Size and Capacity
Q = m3/h ≅ m3/s nominal capacity
Hgeo = m m static head
Hv = m head loss
H ≅ Hp =Hgeo + Hv nominal head at discharge nozzle at the outlet elbow
Hp = m m
ESK ≈ m inlet (E), column pipe (S), and discharge elbow (K) lossesinitially estimated see characteristic curves
HSt = Hp + ESK ≈ m m stage head
SNW size − as per selection chart and characteristic curve
Speed nKL = 1/min speed nKL from curve
Minimum Submergence Depth
zü = m minimum submergence depth to pump inlet nozzle toprevent air entering vortices at maximum capacity
For an unbenched inlet chamber with inlet cone, the graph appliesNOTE: For reduced submergence , KSB can propose covered
inlet chamber on demand.
zs = m difference in level between inlet cross section of the pump and the impeller centre linereference level -- see table below
zü -- zs = m
t11 = m bottom clearance -- see table below
Dimensions in mm
Discharge Nozzle DN z tInlet ChamberDischarge Nozzle DN
DN2zs t11 b e
400 200 260 1000 500
500 250 320 1250 620
600 280 380 1500 750
700 330 440 1800 900
t12 ≥ zü + t11zü
t11
b
e
lmin ≥ b
ze
zü
zs
t11I
II
III
IV
SNWType Series Booklet
5SNWRev.4, 15.05.2002
ze = m minimum submergence depth for cavitation--free operation at Qmin and Qmax
ze ≥ NPSHreq + Hvs –pe + pb – pD
Ãg –v2
e
2g
where
NPSHreq [m] from curve
v2e
2g= 0 ve means flow velocity in the plant inlet cross--section suction water level
Hvs ≈ 0 head loss in suction pipe or in inlet chamber
pe = 0 pressure above atmospheric in the inlet cross section i.e. on the inlet sideliquid level
ze ² NPSHreq -- 10 m, applies if, installation is at sea level therefore pb = 101300 N/m2
ze ² -- 10 m liquid level is open on the suction side
ze ² m the product is water with temperature of approximately 25 oC,corresponding to ρ= 997 kg/m3 and pD = 3170 N/m2
ze ² zü -- zs
Air pressure pb ( absolute pressure) as a function of elevationHeight above sea level
mpb
N/m2
0 101300500 95500
1000 899002000 79500
Vaporization pressure pD (actual pressure at which waterevaporates) and density ρ of water as a function of temperature
Water pD Density ρtemperature Sweet water Seawater
oC N/m2 kg/m3 kg/m3
15 1700 999 1030 to 104020 2340 998 1030 to 104025 3170 997 1030 to 104030 4250 995 1030 to 104035 5600 994 1030 to 104040 7500 992 1030 to 104050 12300 990 1030 to 104060 20000 983 1030 to 1040
I m 1) inlet chamber bottom level
II m 1) level of pump inlet nozzle
III m 1) minimum water level toprevent air entrainment
IV m 1) minimum water level forcavitation--free operation
1) either the minimum suction water level III / IV or the level of inlet chamber bottom / pump inlet must be given
SNWType Series Booklet
6 SNWRev.4, 15.05.2002
Select material combination according to product as per Materials Section page 11
1) Select the optimum bearing arrangement as regards ESK losses (no. of bearings)and price (no. of bearing and shaft diameter) using tables on pages 23 to 74
2) See dimension tables on pages 14, 15, 16 17 and 183) See pages 23 to 744) See page 5
ET
h3
h4
t5
ET
V
VII
VI
II
V
II
VII
Mounting arrangement CD
Mounting arrangement EBn
SNWType Series Booklet
7SNWRev.4, 15.05.2002
Actual ESK losses / stage head
ESK losses = m as per curve pages 21 to 73
HSt = Hp + ESK = m + m
HSt = m
Note the following terms :--
Stage head HSt = the head measured directly downstream of the casing
Stage efficiency ηSt = the efficiency shown in the curves
Pump head Hp = stage head minus ESK losses
Pump efficiency ηp = stage efficiency xpump headstage head
The heads Hst and efficiencies ηSt in the curves refer to a measuring point directly downstream of the pump casing.When selecting a pump bear in mind that these heads will be reduced by the losses in the inlet, riser pipe and dischar-ge elbow of the pump (referred to as ESK losses).
Selection with effective motor speed
Speed from curve, nKL = 1/min
Effective motor speed, nm = 1/min if unknown, refer to pages 21 to 73
QKL = nKL
nm. Q = m3/s
HSt KL = (nKL
nm)2 . HSt = m
Impeller diameter range
D max / mm, D2A1) mm / D2I1) mm refer to curves pages 21 to 73
Stage efficiency / Pump efficiency
ηSt = % stage efficiency, as per curve, pages 21 to 73
ηSt KL =Hp
HSt. ηst = %
1) to be selected from the curves based on the Q KL and H St KL
SNWType Series Booklet
8 SNWRev.4, 15.05.2002
Pump output / Motor output
PB =Q[m3∕s] . HSt[m] . Ã[kg∕m3] . 9.81[m∕s2]
ηSt[–].1000[W∕kW][kW]
PB = 9.811000
[kW]
PB = kW
Px =Qx . HStx . Ã . g
ηStxmaximum power input in operating range
Px = 9.811000
[kW]
P x = kW
PM ² 1.0 Px ² kW when operating range is not known
PM ² 1.1 Px ² kW if it can be ensured that the pump can only be operated at rat--ings below Px, determine pmax and select a motor referredto this output allowing a 10% safety margin.
PM selected kW under special conditions e.g. the priming of siphon pipes atpart--load, a higher motor rating may be required.
Px max. power input in operating rangePB power input at duty pointHx head at max. pump inputHB head at duty pointQx flow rate at max. pump inputQB flow rate at duty pointBx duty point at max. pump inputB duty point
PB
P
Px
H
Hx
HB
0
BxB
Qmin
B
QQx
QB
SNWType Series Booklet
9SNWRev.4, 15.05.2002
Motor data for a computerized quote and for order processing
a.
Motor size is selected
b.
1) Shaft length l mm
2) Shaft diameter d mm
3) Flange connection diameter a1 mm
4) Flange thickness c1 mm
5) Centring diameter b1 mm
6) Spigot depth f1 mm
7) Pitch circle diameter e1 mm
8) No. of bolt holes
9) Bolt hole diameter s1 mm
10) Motor height y mm
11) Radial extension (terminal box) XB mm
12) Casing diameter g mm
13) Weight m kg
Note:--Dimensions for Sr. 1 to 3 at project stageDimensions for Sr. 4 to 13 at order stage
Further customer information
Starting torquesRefer to booklet 0110.001/2 G2 “Starting Torques”
Assuming a ratio of:--
static delivery headnominal head
=HStat
HN 0,8 1)
and a short discharge line with a non--return valve, the starting torquewill be represented by a broken line in Fig. 2
TPN = 9550 ¡Pp [k W]
nM [1∕min][Nm]
TPN = 9550 ¡ [Nm]
1) other boundary conditions on request
Motor type/size known j
Motor type/size not known j enclosure
j Guaranteed performance data to ISO 2548, class C, standard
j Acceptance testing to ISO 3555, class B
Anticipated operating hours h/a
SNWType Series Booklet
10 SNWRev.4, 15.05.2002
Operating LimitsTest Pressure of the discharge elbow : Pe = 1.2 x closed valve head, max. 10 bar
Closed valve head:--Pressure corresponding to the shut--off head of the pump plus the suction pressure or the total pressure at the pump dischargenozzle during operation at zero flow rate (Q=0)
Product temperatures : t = 0 to 60 oCAmbient temperatures : t = --10 to 50 oCFor speeds refer to selection chart.
ShaftsPump shaft, intermediate and drive shafts are connected by sealed sleeve couplings.
Shaft SealingOn pumps in CD mounting arrangement, effected by the upper most shaft guide bearing as a result of throttling action in the bearing.Arrangement EB and/or EK has a packed gland.On CD pumps the sealing liquid is drained off via a small pipe located near the discharge elbow. On EB and/or EK pumps, whichare non flood--proof, the leakage liquid is drained off via a pipe through a bore hole in the discharge elbow into the inlet chamber.On the flood--proof arrangement, a leakage water drain is to be provided by the customer.
Shaft Guide BearingsProduct--lubricated plain bearings. The bearing bushes are flexibly located in a renewable bearing body, by a layer of rubber.The pumps are started up dry without any pre--lubrication. Permissable dry running period ± 15 s.
Shaft Protecting SleevesThe sleeve situated in the area of packed gland can be easily renewed without removing the shaft. The sleeve at the bearing ismade of wear--resistant silicon carbide and is also renewable.
Thrust BearingGrease--lubricated antifriction bearings. For bearing sizes see pages 23 to 74.Lubricant type : K2k to DIN 51 502.
DriveDrive via IEC standard motors with lateral cooling--air outlet. The direction of rotation of the pump is clockwise viewed from thedriver. A FLENDER N--EUPEX drive coupling is used with the hub of the pump--side half coupling specially adapted to the particularthrust bearing. The design of the drive stool ensures that there is no danger of accidental contact with the drive coupling.All the usual starting modes are permissible, however, bear in mind that star/delta starting is not always feasible depending uponthe system arrangement.
Mounting ArrangementsVertical wet--well installation--Mounting arrangement CD : discharge pipe below ground level, drive motor above ground level--Mounting arrangement EB and/or EK : discharge pipe and motor above ground level
FoundationsMounting arrangement CD : Drive motor mounted on cast iron foundation blocks, concreted into position.Mounting arrangement EB and/or EK : The riser pipe is attached to a flat steel foundation ring with sealing action, or to foundationblocks, both of which are concreted into place. The foundation ring is held in place by anchor bolts. On the flood--proof (pressure--proof) version a seal ring is fitted between the mounting flange and the foundation ring.
Clear PassageThe pump must be protected against the entry of any large solid particles in the product by the installation of suitable dirt and shingletraps i.e. overflow sims, scum boards, rakes, etc. upstream of the pump (see page 3). Relevant experience and the clear passagegiven for various pump sizes (see table Technical Data -- page 12) should be taken into consideration at the design stage.
Performance CurvesThe NPSHreq curves relate to continuous operation with impeller materials as specified in the documentation.The heads and performance data are for a product with density ± = 1.0 kg/dm3 and a kinematic viscosity ↑ of up to 20 mm2/s max.
Inspection and TestingThe performance data are guaranteed without acceptance test as per ISO 2548, class C.Inspection testing and certification to ISO 3555, class B, 5 measuring points, is available at an extra charge.
GuaranteesKSB assumes guarantees within the frame work of its relevant conditions of supply.
Scope of Supply Accessories--pump --IEC electric motor--drive coupling --pressure gauge arrangement--inlet cone --special tools--foundation blocks
SNWType Series Booklet
11SNWRev.4, 15.05.2002
Materials
Standard program Custom made program4)
Material combination 01 02 03 04 05Part--No. Part designation Materials138 Inlet Nozzle GG--20 (GJL--200) Ni Resist 1.45172) /1.44623)
86--2 Coupling sleeve, cylindrical C 45 N 1.4021.05 1.4462891 Foundation ring GG--20 (GJL--200)898 Foundation bloc GG--20 (GJL--200)Misc. Bolts and nuts 8.8 A4--70 1.4462
1) Bolted to the pump2) Cast3) Welded4) On request5) Equivalent to DIN: 1.4571
SNWType Series Booklet
12 SNWRev.4, 15.05.2002
Coating
A ) Standard coating :
surfaces in contact with medium surfaces not in contact with medium
Pretreatment Blasting SA 2 1/2 , DIN 55928 T4
Primer 2--component Hi--build epoxy Zinc Phosphate Primer
Top coat 2--component Polyamide cured epoxycoaltar, ICI CTE--200, thickness 0.300,
Black RAL 9005
1--component--acrylat--alkyd based coat, thickness 0.06 mm,RAL 5002 ultramarinblau (blue)
B ) Special coating (approved for Potable Water and Cold Sea Water (<24____C) applications) :
surfaces in contact with medium surfaces not in contact with medium
Pretreatment Blasting SA 2 1/2 , DIN 55928 T4
Primer 2--component modified epoxy amine primer, Carboline 893 1)
Top coat 2--component epoxy Carboline 891 2),thickness 0.150 mm,
black RAL 9005
1--component--acrylat--alkyd based coat, thickness 0.06 mm,RAL 5002 ultramarinblau (blue)
1) Primer applied only if specially requested by the Customer, the Carboline 891 is applied directly on the surface as standard practice2) NSF, National Public Health (Norway), Drinking Water Certificate
C ) Special coating as per Customer’s Specification :against extra charge dependent on individual projects.
SNWType Series Booklet
13SNWRev.4, 15.05.2002
TECHNICAL DATAThe given forces and moments are mean values for simultaneous loading in the three planes. If the forces and mo-ments in one particular direction are larger than given in the table, refer to us.
The values in the tables are not valid for the reaction forces of non--tensioned expansion joints.
On mounting arrangement CD the discharge pipe must be located in the axial direction. Maximum distance of thefixed point from the discharge nozzle : 4 m. An elbow support is also necessary if the discharge pipe has a flexibleextension piece. Maximum length of support : 4 m.
Dimensions in mm, Forces in N, Moments in Nm
Pump Technical data 1) Nozzle forces and moments
size Impellerinlet dia
Casingwear ring
dia
Impellerclea-rance
Clearpassages�10%
Impelleropen
Impellerclosed
ForceFX
ForceFY
ForceFZ
Nozzlemoment
MX
Nozzlemoment
MY
Nozzlemoment
MZ
400--365 290 -- 0,45 55 X --400--405 314 -- 0,55 52 X --400--420 286 -- 0,45 52 X -- 6500 6500 6500 1450 1450 1450400--430 325 330 0,60 52 -- X
6500 6500 6500 1450 1450 1450
400--450 340 380 0,60 43 -- X
500--505 380 -- 0,55 57 X --500--515 392 -- 0,55 84 X -- 8700 8700 8700 1800 1800 1800500--620 382 425 0,60 65 -- X
8700 8700 8700 1800 1800 1800
600--535 425 -- 0,60 81 X --600--550 420 -- 0,60 62 X --600--575 460 -- 0,60 76 X --600--600 455 -- 0,60 76 X -- 10700 10700 10700 2300 2300 2300600--650 452 500 0,60 66 -- X
700--655 547 -- 0,75 114 X --700--715 532 -- 0,75 81 X -- 14000 14000 14000 2800 2800 2800700--755 588 -- 0,75 100 X --
14000 14000 14000 2800 2800 2800
1) For further data see pages 22 up to 73
SNWType Series Booklet
14 SNWRev.4, 15.05.2002
DIMENSION TABLES
CD Mounting Arrangement
The pump is shown without a driver.
All dimensions which relate to the type and size of the driver and installation / structure can be supplied on request.
Pump driven by IEC standard motor with lateral inlet cooling air outlet.
Where the piping is flexibly connected to the discharge elbow, the thrust must be accomodated by suitable means.
Dimensions t2 to t4 and d2 on request.
Connections
1 M Pressure Guage G ½8 A Leakage fluid outlet G ½
Permitted Dimensional Tolerances
Centreline heights DIN 747.Dimensions with no tolerance DIN 7168 m.Cast iron components DIN 1686 GTB 18
Discharge Flange
Connection dimensions to DIN 2501, PN 10Flange thickness* to DIN EN 1092--2, PN 6* for operating pressure ≥ 6 bar DIN EN 1092--2, PN 10
Dimensions in mm, non--bindingPump Pump dimensionsu psize DN2 t5 min a d1 h1 h2 h3 min t1
400--365 1350 550 700
400--405 1450 550 800
400--420 400 1475 400 550 400 750 615 825
400--430400
1390400
550400 750 615
740
400--450 1625 600 975
500--505 1630 645 880
500--515 500 1850 500 645 500 870 620 1100
500--620500
1780500
645500 870 620
1030
600--535 1860 700 1010
600--550 1895 700 1045
600--575 2065 775 1215
600--600 600 1930 600 775 600 990 620 1080
600--650600
2050600
775600 990 620
1200
600--700 1950 750 1100
600--720 2060 750 1210
700--655 2500 900 1550
700--715 700 2180 700 870 700 1125 690 1230
700--755700
2410700
980700 1125 690
1460
Pump Feet dimensions Foundation dimensionsu psize m n o1 o2 p1 p2
400--365 800 950 750 500 650 750
400--405 800 950 750 500 650 750
400--420 800 1050 750 500 750 850
400--430 800 950 750 500 650 750
400--450 940 1120 900 640 820 920
500--505 940 1120 900 640 820 920
500--515 940 1120 900 640 820 920
500--620 1140 1200 1100 840 900 1000
600--535
600--550
600--575
600--600 1140 1200 1100 840 900 1000
600--650
600--700 1400 1100 1200
600--720 1340 1500 1300 1040 1200 1300
700--655
700--715 1340 1400 1300 1040 1100 1200700--755
1340 1400 1300 1040 1100 1200
h2
t4
t3
t3
t2
t1
ET
h3
d2
a
DN2
h4
h1
t5
300
200
d1
m50 50
25
25
n
4 holes 27
o1
p1 p2
200 200o2
250
8A
1M
Plan view
Foundationholes
For ETmax and h4 seetable
“Technical dataand dimensions”
SNWType Series Booklet
15SNWRev.4, 15.05.2002
DIMENSION TABLESEB Mounting Arrangement (EBn) -- Non floodable versionThe pump is shown without a driver.All dimensions which relate to the type and size of the driver and installation / structure can be supplied on request.Pump driven by IEC standard motor with lateral inlet cooling air outlet.Where the piping is flexibly connected to the discharge elbow, the thrust must be accomodated by suitable means.Dimensions t2 to t4 and d2 on request.
Connections
1 M Pressure Guage G ½ For ETmax and h1 see table
Permitted Dimensional Tolerances “Technical Data and Dimensions”
Centreline heights DIN 747.Dimensions with no tolerance DIN 7168 m.Cast iron components DIN 1686 GTB 18
Discharge Flange
Connection dimensions to DIN 2501, PN 10Flange thickness* to DIN EN 1092--2, PN 6* for operating pressure ≥ 6 bar DIN EN 1092--2, PN 10
DN2 Permitted drive flange diameters d2 in mm400 up to 660500 up to 800
for larger flange see page 17600 up to 1100 for larger flange see page 17
700 up to 1200
Dimensions in mm, non--binding
Pump Pump dimensionsPumpsize DN2 ETmin a d1 h1 h2 h3 max t1
400--365 940 550 700
400--405 1040 550 800
400--420 400 1065 400 550 400 750 415 825
400--430400
1040400
550400 750 415
740
400--450 1275 600 975
500--505 1180 645 880
500--515 500 1400 500 645 500 870 420 1100
500--620500
1330500
645500 870 420
1030
600--535 1310 700 1010
600--550 1345 700 1045
600--575 1515 775 1215
600--600 600 1380 600 775 600 990 420 1080
600--650600
1500600
775600 990 420
1200
600--700 1400 750 1100
600--720 1510 750 1210
700--655 1950 900 1550
700--715 700 1630 700 870 700 1125 490 1230
700--755700
1860700
980700 1125 490
1460
Pump Feet dimensions Foundation dimensionsPumpsize m n s o1 o2 p1 p2
400--365 950 700 650 750 650 400
400--405 950 700 650 750 650 400
400--420 1050 800 30 750 850 750 500
400--430 950 70030
650 750 650 400
400--450 1050 800 750 850 750 500
500--505 1050 800 30 750 850 750 500
500--515 1050 800 30 750 850 750 500
500--620 1200 940 35 900 1000 900 640
600--535
600--550
600--575 1200 940 35 900 1000 900 640600--600
1200 940 35 900 1000 900 640
600--650
600--700 1400 114035
1100 1200 1100 840
600--720 1500 124035
1200 1300 1200 940
700--655
700--715 1400 1140 40 1100 1200 1100 840700--755
1400 1140 40 1100 1200 1100 840
t4
t3
t3
t3
t2
t1
h2
h3
ET
DN2
1M
h1
250
200
300
d2
d1
m
o1
o2
n
p2
4 holes 27
p1
25 25 50
50
200
200
a
Plan view
Foundationholes
s
SNWType Series Booklet
16 SNWRev.4, 15.05.2002
DIMENSION TABLESEB Mounting Arrangement (EBd) -- Floodable versionThe pump is shown without a driver.All dimensions which relate to the type and size of the driver and installation / structure can be supplied on request.Pump driven by IEC standard motor with lateral inlet cooling air outlet.Where the piping is flexibly connected to the discharge elbow, the thrust must be accomodated by suitable means.Dimensions t2 to t4 and d2 on request.
Connections
1 M Pressure Guage G ½ For ETmax and h1 see table
8 A Leaking liquid outlet G ½ “Technical Data and Dimensions”
Permitted Dimensional Tolerances
Centreline heights DIN 747.Dimensions with no tolerance DIN 7168 m.Cast iron components DIN 1686 GTB 18
Discharge Flange
Connection dimensions to DIN 2501, PN 10Flange thickness* to DIN EN 1092--2, PN 6* for operating pressure ≥ 6 bar DIN EN 1092--2, PN 10
DN2 Permitted drive flange diameters d2 in mm
400 up to 660500 up to 800
for larger flange see page 18600 up to 1100 for larger flange see page 18
700 up to 1200
Dimensions in mm, non--binding
Pump Pump dimensionsPumpsize DN2 ETmin a d1 h1 h2 h3 max t1
400--365 950 550 700
400--405 1050 550 800
400--420 400 1075 400 550 400 750 415 825
400--430400
990400
550400 750 415
740
400--450 1225 600 975
500--505 1130 645 880
500--515 500 1350 500 645 500 870 420 1100
500--620500
1280500
645500 870 420
1030
600--535 1260 700 1010
600--550 1295 700 1045
600--575 1465 775 1215
600--600 600 1330 600 775 600 990 420 1080
600--650600
1450600
775600 990 420
1200
600--700 1350 750 1100
600--720 1460 750 1210
700--655 1800 900 1550
700--715 700 1480 700 870 700 1125 490 1230
700--755700
1710700
980700 1125 490
1460
Pump Feet dimensions Foundation dimensionsPumpsize d3 d4 s x y1 d5 d6 d7 y2
DIMENSION TABLESEK Mounting Arrangement (EKn) Non-- floodable versionThe pump is shown without a driver.All dimensions which relate to the type and size of the driver and installation / structure can be supplied on request.Pump driven by IEC standard motor with lateral inlet cooling air outlet.Where the piping is flexibly connected to the discharge elbow, the thrust must be accomodated by suitable means.Dimensions t2 to t4 and d2 on request.
Connections
1 M Pressure Guage G ½ For ETmax and h1, see table
Permitted Dimensional Tolerances “Technical Data and Dimensions”
Centreline heights DIN 747.Dimensions with no tolerance DIN 7168 m.Cast iron components DIN 1686 GTB 18
Discharge Flange
Connection dimensions to DIN 2501, PN 10Flange thickness* to DIN EN 1090--2, PN 6* for operating pressure ≥ 6 bar DIN EN 1092--2, PN 10
Pump Pump dimensionsPumpsize DN2 ETmin a d1 h1 h2 h3 max t1
400--365 940 550 700
400--405 1040 550 800
400--420 400 1065 400 550 400 750 415 825
400--430400
1040400
550400 750 415
740
400--450 1275 600 975
500--505 1180 645 880
500--515 500 1400 500 645 500 870 420 1100
500--620500
1330500
645500 870 420
1030
600--535 1310 700 1010
600--550 1345 700 1045
600--575 1515 775 1215
600--600 600 1380 600 775 600 990 420 1080
600--650600
1500600
775600 990 420
1200
600--700 1400 750 1100
600--720 1510 750 1210
700--655 1950 900 1550
700--715 700 1630 700 870 700 1125 490 1230
700--755700
1860700
980700 1125 490
1460
Pump Feet dimensions Foundation dimensionsu psize m n s o1 o2 p1 p2
400--365 950 700 650 750 650 400
400--405 950 700 650 750 650 400
400--420 1050 800 30 750 850 750 500
400--430 950 70030
650 750 650 400
400--450 1050 800 750 850 750 500
500--505 1050 800 30 750 850 750 500
500--515 1050 800 30 750 850 750 500
500--620 1200 940 35 900 1000 900 640
600--535
600--550
600--575 1200 940 35 900 1000 900 640600--600
1200 940 35 900 1000 900 640
600--650
600--700 1400 1140 1100 1200 1100 840
600--720 1500 1240 1200 1300 1200 940
700--655
700--715 1400 1140 40 1100 1200 1100 840700--755
1400 1140 40 1100 1200 1100 840
t4
t3
t3
t3
t2
t1
ET
h3
h2
a
h1
d1
250
200
300
m25 25
50
n
o1
p1
p2
200
200
o2
d2
1M
DN2
50
s
4 holes 27
Plan view
Foundationholes
SNWType Series Booklet
18 SNWRev.4, 15.05.2002
DIMENSION TABLESEK Mounting Arrangement (EKd) -- Floodable versionThe pump is shown without a driver.All dimensions which relate to the type and size of the driver and installation / structure can be supplied on request.Pump driven by IEC standard motor with lateral inlet cooling air outlet.Where the piping is flexibly connected to the discharge elbow, the thrust must be accomodated by suitable means.Dimensions t2 to t4 and d2 on request.
Connections1 M Pressure Guage G ½ For ETmax and h1, see table8 A Leakage fluid outlet G ½ “Technical Data and Dimensions”
Permitted Dimensional TolerancesCentreline heights DIN 747Dimensions with no tolerance DIN 7168 mCast iron components DIN 1686 GTB 18
Discharge FlangeConnection dimensions to DIN 2501, PN 10Flange thickness* to DIN EN 1092--2, PN 6* for operating pressure ≥ 6 bar DIN EN 1092--2, PN 10
BEARING ARRANGEMENTEBn and EKn and/or EBd and EKd Mounting Arrangement
2 3K 3 4K
4 5K 5 6K
6 7K 7
SNWType Series Booklet
21SNWRev.4, 15.05.2002
SNW 400--36550 Hzn = 1480 1/min
OpenImpeller
A = EB 7 ; EB 7KB = CD 7 ; CD 7K ; EB 6; EB 6KC = CD 6 ; CD 6K ; EB 5; EB 5KD = CD 5 ; CD 5K ; EB 4; EB 4KE = CD 4 ; CD 4K ; EB 3; EB 3KF = CD 3 ; EB 2Typical Pump Designation:--EB 5K
Q [l/s]0 100 200 300 400 500 600
H--St [m]
0
5
10
15
20
25
30
35
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
10
12
14
16
P [kW]
0
40
80
120
NR : D2A/ D2I[mm]
4 : 363/ 2783 : 352/ 2542 : 346/ 2391 : 329/ 200
Rho = 1000 [kg/m3] n = 1480 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 363/ 2783 : 352/ 2542 : 346/ 2391 : 329/ 200
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
22 SNWRev.4, 15.05.2002
SNW 400--36560 Hzn = 1180 1/min
OpenImpeller
B = CD 7 ; CD 7K ; EB 6; EB 6KC = CD 6 ; CD 6K ; EB 5; EB 5KD = CD 5 ; CD 5K ; EB 4; EB 4KE = CD 4 ; CD 4K ; EB 3; EB 3KF = CD 3 ; EB 2Typical Pump Designation:--EB 5K
Q [l/s)0.00 80 160 240 320 400 480
H--St [m]
0
5
10
15
20
25
30
35
40
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
6
7
8
9
10
11
P [kW]
0
20
40
60
Rho = 1000 [kg/m3] n = 1180 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 363/ 2783 : 352/ 2542 : 346/ 2391 : 329/ 200
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
23SNWRev.4, 15.05.2002
SNW 400--36550 Hzn = 1480 1/min
Technical data and Dimensions
Mounting arrangement CD
Material combination 1) 01
Shaft diameter 50 40
P/n shaft (mat comb 01) 0,15 0,065
Drive coupling size 2) B 225 B 200 B 180
P/n Drive coupling 0,21 0,14 0,092
Thrust bearing size 7220 B. UA 7216 B. UA
h 4 min 1050 912
h 4 max3) 2140 1918
Bearing arrangement t5max3) J t5max
3) J
3 2200 0,45 2020 0,39
4K -- -- 2590 0,39
4 3890 0,45 3540 0,39
5K -- -- 4100 0,39
5 5580 0,45 5050 0,39
6K -- -- 5620 0,39
6 7240 0,45 6530 0,39
7K -- -- 7130 0,39
7 -- -- 7890 0,39all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=1480 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply fugures by 1,12
7 10030 0,46 8930 0,40all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=1480 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 1,12
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EBn
SNWType Series Booklet
24 SNWRev.4, 15.05.2002
SNW 400--40550 Hzn = 1480 1/min
OpenImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 120 240 360 480 600 720
H--St [m]
0
10
20
30
40
50
60
70
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
7.5
10.0
12.5
15.0
17.5
P [kW]
50
100
150
200
NR : D2A/ D2I[mm]
4 : 420/ 3353 : 401/ 2972 : 387/ 2661 : 372/ 232
Rho = 1000 [kg/m3] n = 1480 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
25SNWRev.4, 15.05.2002
SNW 400--40560 Hzn = 1180 1/min
OpenImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 100 200 300 400 500 600
H--St [m]
0
5
10
15
20
25
30
35
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
6
8
10
12
14
16
P [kW]
25
50
75
100
NR : D2A/ D2I[mm]
4 : 420/ 3353 : 401/ 2972 : 387/ 2661 : 372/ 232
Rho = 1000 [kg/m3] n = 1180 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
26 SNWRev.4, 15.05.2002
SNW 400--40550 Hzn = 1480 1/min
Technical Data and Dimensions
Mounting arrangement CD
Material combination 1) 01
Shaft diameter 60 50 40
P/n shaft (mat comb 01) 0,28 0,15 0,065
Drive coupling size 2) B 280 B 250 B 225 B 200 B 180
P/n Drive coupling 0,41 0,29 0,21 0,14 0,092
Thrust bearing size 7222 B. UA 7222 B. UA 7222 B. UA
h 4 min 1146 1064 1064
h 4 max3) 2298 2155 2155
Bearing arrangement t5max3) J t5max
3) J t5max3) J
3 2480 0,88 2300 0,82 2300 0,57
4K -- -- -- -- -- --
4 4330 0,88 3990 0,82 3990 0,57
5K -- -- -- -- -- --
5 6180 0,88 5680 0,82 5680 0,57
6K -- -- -- -- -- --
6 8030 0,88 7340 0,82 7340 0,57
7K -- -- -- -- -- --
7 -- -- -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=1480 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 1,12
Mounting arrangement EKn / EKd
Material combination 1) 01
Shaft diameter 60 50 40
P/n shaft (mat comb 01) 0,28 0,15 0,065
Drive coupling size 2) B 280 B 250 B 225 B 200 B 180
P/n Drive coupling 0,41 0,29 0,21 0,14 0,092
Thrust bearing size 7222 B. UA 7222 B. UA 7222 B. UA
Bearing arrangement ETmax3) J ETmax
3) J ETmax3) J
2 1850 0,92 1690 0,83 0,58
3K -- -- -- -- -- --
3 3700 0,92 3370 0,83 0,58
4K -- -- -- -- -- --
4 5530 0,92 5050 0,83 0,58
5K -- -- -- -- -- --
5 7390 0,92 6760 0,83 0,58
6K -- -- -- -- -- --
6 9250 0,92 8420 0,83 0,58
7K -- -- -- -- -- --
7 11040 0,92 10130 0,83 0,58
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=1480 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 1,12
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EKn
SNWType Series Booklet
27SNWRev.4, 15.05.2002
SNW 400--42050 Hzn = 1450 1/min
OpenImpeller
B = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 100 200 300 400 500 600
H--St [m]
10
15
20
25
30
35
40
45
50
55
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
6
8
10
12
14
16
P [kW]
50
100
150
200
NR : D2A/ D2I[mm]
3 : 427/ 3642 : 407/ 3381 : 391/ 315
Rho = 1000 [kg/m3] n = 1450 [1/min]
1
1
1
1
2
2
2
3
3
3
3
Qmin
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
28 SNWRev.4, 15.05.2002
SNW 400--42060 Hzn = 1160 1/min
OpenImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 80 160 240 320 400 480
H--St [m]
4
8
12
16
20
24
28
32
36
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
4
6
8
10
12
14
P [kW]
40
60
80
100
NR : D2A/ D2I[mm]
3 : 427/ 3642 : 407/ 3381 : 391/ 315
Rho = 1000 [kg/m3] n = 1160 [1/min]
1
1
1
1
2
2
2
3
3
3
3
Qmin
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
29SNWRev.4, 15.05.2002
SNW 400--42050 Hzn = 1450 1/min
Technical Data and Dimensions
Mounting arrangement CD
Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15
Drive coupling size 2) B 280 B 250 B 225 B 200
P/n Drive coupling 0,41 0,29 0,21 0,14
Thrust bearing size 7226 B.UA 7226 B.UA
h 4 min 1148 1066
h 4 max3) 2300 2157
Bearing arrangement t5max3) J t5max
3) J t5max3) J
3 2505 1,19 2325 1,10
4K -- -- -- --
4 4355 1,19 4015 1,10
5K -- -- -- --
5 6205 1,19 5705 1,10
6K -- -- -- --
6 8055 1,19 7365 1,10
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=1450 1/min, 50 Hz; for n=1160 1/min, 60 Hz, multiply figures by 1,12
Mounting arrangement EKn / EKd
Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15
Drive coupling size 2) B 280 B 250 B 225 B 200
P/n Drive coupling 0,41 0,29 0,21 0,14
Thrust bearing size 7226 B.UA 7226 B.UA
Bearing arrangement ETmax3) J ETmax
3) J ETmax3) J
2 1870 1.21 1710 1,11
3K -- -- -- --
3 3730 1.21 3400 1,11
4K -- -- -- --
4 5560 1.21 5070 1,11
5K -- -- -- --
5 7420 1.21 6780 1,11
6K -- -- -- --
6 9280 1.21 8440 1,11
7K -- -- -- --
7 11070 1.21 10150 1,11
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=1450 1/min, 50 Hz; for n=1160 1/min, 60 Hz, multiply figures by 1,12
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EKn
SNWType Series Booklet
30 SNWRev.4, 15.05.2002
SNW 400--43050 HZn = 1480 1/min
ClosedImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 100 200 300 400 500 600
H--St [m]
0
10
20
30
40
50
60
70
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
10
12
14
16
P [kW]
100
150
200
250
NR : D2A/ D2I[mm]
4 : 425/ 3753 : 415/ 3572 : 405/ 3401 : 395/ 320
Rho = 1000 [kg/m3] n = 1480 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 425/ 3753 : 415/ 3572 : 405/ 3401 : 395/ 320
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
31SNWRev.4, 15.05.2002
SNW 400--43060 HZn = 1180 1/min
ClosedImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 80 160 240 320 400 480
H--St [m]
0
5
10
15
20
25
30
35
40
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
6
7
8
9
10
P [kW]
0
50
100
150
NR : D2A/ D2I[mm]
4 : 425/ 3753 : 415/ 3572 : 405/ 3401 : 395/ 320
Rho = 1000 [kg/m3] n = 1180 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 425/ 3753 : 415/ 3572 : 405/ 3401 : 395/ 320
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
32 SNWRev.4, 15.05.2002
SNW 400--43050 HZn = 1480 1/min
Technical Data and DimensionsMounting arrangement CD
Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15
Drive coupling size 2) B 280 B 250 B 225 B 200
P/n Drive coupling 0,41 0,29 0,21 0,14
Thrust bearing size 7322 B.UA 4)
7324 B.UA 5)7322 B.UA
h 4 min 1163 1076
h 4 max3) 2310 2166
Bearing arrangement t5max3) J t5max
3) J t5max3) J
3 2420 1,61 2240 1,52
4K -- -- -- --
4 4270 1,61 3930 1,52
5K -- -- -- --
5 6120 1,61 5620 1,52
6K -- -- -- --
6 7970 1,61 7280 1,52
7K -- -- -- --
7 -- -- -- --all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=1480 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 1,124) Up to t5 max = 4270 mm 5) Up to t5 max= 7970mm
Mounting arrangement EKn / EKd
Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15Drive coupling size 2) B 280 B 250 B 225 B 200
P/n Drive coupling 0,41 0,29 0,21 0,14
Thrust bearing size 7322 B.UA 4)
7324 B.UA 5)
7322 B.UA
Bearing arrangement ETmax3) J ETmax
3) J ETmax3) J
2 1790 1,63 1630 1,53
3K -- -- -- --
3 3640 1,63 3310 1,53
4K -- -- -- --
4 5470 1,63 4990 1,53
5K -- -- -- --
5 7330 1,63 6700 1,53
6K -- -- -- --
6 9190 1,63 8360 1,53
7K -- -- -- --
7 10980 1,63 10070 1,53all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=1480 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 1,124) Up to ET max = 5470 mm 5) Upto ET max = 10980mm
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EKn
SNWType Series Booklet
33SNWRev.4, 15.05.2002
SNW 400--45050 Hzn = 1450 1/min
ClosedImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 120 240 360 480 600 720
H--St [m]
10
20
30
40
50
60
70
80
90
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
8
10
12
14
P [kW]
150
200
250
300
NR : D2A/ D2I[mm]
2 : 450/ 410
Rho = 1000 [kg/m3] n = 1450 [1/min]
1
1
1
1
2
2
2
2
Qmin
NR : D2A/ D2I[mm]
2 : 450/ 4101 : 419/ 362
Curves as per 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
34 SNWRev.4, 15.05.2002
SNW 400--45060 Hzn = 1180 1/min
ClosedImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 100 200 300 400 500 600
H--St [m]
10
15
20
25
30
35
40
45
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
6
7
8
9
10
P [kW]
50
100
150
200
NR : D2A/ D2I[mm]
2 : 450/ 4101 : 419/ 362
Rho = 1000 [kg/m3] n = 1180 [1/min]
1
1
1
1
2
2
2
2
Qmin
NR : D2A/ D2I[mm]
2 : 450/ 4101
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
35SNWRev.4, 15.05.2002
SNW 400--45050 Hzn = 1450 1/min
Technical Data and DimensionsMounting arrangement CD
Material combination 1) 01
Shaft diameter 60
P/n shaft (mat comb 01) 0,28
Drive coupling size 2) B 280 B 250
P/n Drive coupling 0,41 0,29
Thrust bearing size 7330 B.UA 4)
7334 B.UA 5)
h 4 min 1248
h 4 max3) 2375
Bearing arrangement t5max3) J t5max
3) J t5max3) J
3 2655 2,70
4K -- --
4 4505 2,70
5K -- --
5 6355 2,70
6K -- --
6 8205 2,70
7K -- --
7 -- --all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=1450 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 1,124) Up to t5 max = 6355 mm5) Up to t5 max = 8205 mm6) Lubrication intervals and quantities see page 13
Mounting arrangement EKn / EKd
Material combination 1) 01
Shaft diameter 60
P/n shaft (mat comb 01) 0,28
Drive coupling size 2) B 280 B 250
P/n Drive coupling 0,41 0,29
Thrust bearing size 7330 B.UA 4)
7334 B.UA 5)
Bearing arrangement ETmax3) J ETmax
3) J ETmax3) J
2 2020 2,72
3K -- --
3 3880 2,72
4K -- --
4 5710 2,72
5K -- --
5 7570 2,72
6K -- --
6 9430 2,72
7K -- --
7 11220 2,72all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=1450 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 1,114) Up to ET max = 7570 mm 5) Up to ETmax = 11220
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EKn
SNWType Series Booklet
36 SNWRev.4, 15.05.2002
SNW 500--50550 Hzn = 980 1/min
OpenImpeller
A = EB 7 ; EB 7KB = CD 7 ; CD 7K ; EB 6; EB 6KC = CD 6 ; CD 6K ; EB 5; EB 5KD = CD 5 ; CD 5K ; EB 4; EB 4KE = CD 4 ; CD 4K ; EB 3; EB 3KF = CD 3 ; EB 2Typical Pump Designation:--EB 5K
Q [l/s]0 160 320 480 640 800 960
H--St [m]
4
8
12
16
20
24
28
32
36
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
8
10
12
14
16
18
P [kW]
40
80
120
160
NR : D2A/ D2I[mm]
4 : 500/ 4283 : 489/ 4072 : 474/ 3761 : 448/ 320
Rho = 1000 [kg/m3]
Curves as per ISO 2548C
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 500/ 4283 : 489/ 4072 : 474/ 3761 : 448/ 320
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
37SNWRev.4, 15.05.2002
SNW 500--50560 Hzn = 880 1/min
OpenImpeller
A = EB 7 ; EB 7KB = CD 7 ; CD 7K ; EB 6; EB 6KC = CD 6 ; CD 6K ; EB 5; EB 5KD = CD 5 ; CD 5K ; EB 4; EB 4KE = CD 4 ; CD 4K ; EB 3; EB 3KF = CD 3 ; EB 2Typical Pump Designation:--EB 5K
0 400 800 1200 1600 2000 2400
H--St [m]
4
8
12
16
20
24
28
32
36
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
6
8
10
12
14
P [kW]
40
80
120
160
NR : D2A/ D2I[mm]
4 : 500/ 4283 : 489/ 4072 : 474/ 3761 : 448/ 320
Rho = 1000 [kg/m3] n = 880 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 500/ 4283 : 489/ 4072 : 474/ 3761 : 448/ 320
Curves as per ISO 2548C
Q [l/s]
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
38 SNWRev.4, 15.05.2002
SNW 500--50550 Hzn = 980 1/min
Technical Data and DimensionsMounting arrangement CD
Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15
Drive coupling size 2) B 280 B 250 B 225 B 200
P/n Drive coupling 0,41 0,29 0,21 0,14
Thrust bearing size 7222 B.UA 4)
7226 B.UA 5)7222 B.UA
h 4 min 1182 1084
h 4 max3) 2750 2556
Bearing arrangement t5max3) J t5max
3) J t5max3) J
3 2940 2,11 2740 2,02
4K 3630 2,11 3430 2,02
4 5210 2,11 4820 2,02
5K 5900 2,11 5500 2,02
5 7480 2,11 6890 2,02
6K 8140 2,11 7550 2,02
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,064) Up to t5 max = 3630 mm 5) Up to t5 max = 8140mm
Mounting arrangement EBn / EBd
Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15
Drive coupling size 2) B 280 B 250 B 225 B 200
P/n Drive coupling 0,41 0,29 0,21 0,14
Thrust bearing size 7222 B.UA 4)
7226 B.UA 5)7222 B.UA
Bearing arrangement ETmax3) J ETmax
3) J ETmax3) J
2 2230 2,12 2030 2,03
3K 3100 2,12 2900 2,03
3 4490 2,12 4100 2,03
4K 5360 2,12 4960 2,03
4 6770 2,12 6170 2,03
5K 7630 2,12 7030 2,03
5 9040 2,12 8240 2,03
6K 9900 2,12 9100 2,03
6 11310 2,12 10310 2,03
7K -- -- 11170 2,03
7 -- -- -- --all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,064) Up to ET max = 5360 mm 5) Upto ETmax = 11310
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EBn
SNWType Series Booklet
39SNWRev.4, 15.05.2002
SNW 500--51550 Hzn = 960 1/min
OpenImpeller
A = EB 7 ; EB 7KB = CD 7 ; CD 7K ; EB 6; EB 6KC = CD 6 ; CD 6K ; EB 5; EB 5KD = CD 5 ; CD 5K ; EB 4; EB 4KE = CD 4 ; CD 4K ; EB 3; EB 3KF = CD 3 ; EB 2Typical Pump Designation:--EB 5K
Q [l/s]0 150 300 450 600 750 900
H--St [m]
0
5
10
15
20
25
30
35
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
6
8
10
12
14
16
P [kW]
50
100
150
200
NR : D2A/ D2I[mm]
4 : 502/ 3453 : 482/ 3292 : 463/ 3091 : 443/ 274
Rho = 1000 [kg/m3] n = 960 [1/min]
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 502/ 3453 : 482/ 3292 : 463/ 3091 : 443/ 274
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
40 SNWRev.4, 15.05.2002
SNW 500--51560 Hzn = 875 1/min
OpenImpeller
A = EB 7 ; EB 7KB = CD 7 ; CD 7K ; EB 6; EB 6KC = CD 6 ; CD 6K ; EB 5; EB 5KD = CD 5 ; CD 5K ; EB 4; EB 4KE = CD 4 ; CD 4K ; EB 3; EB 3KF = CD 3 ; EB 2Typical Pump Designation:--EB 5K
Q [l/s]0 150 300 450 600 750 900
H--St [m]
0
5
10
15
20
25
30
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
6
8
10
12
14
16
P [kW]
0
80
160
240
Rho = 1000 [kg/m3] n = 875 [1/min]
NR:D2A/D2I(mm)
4: 502/345
3: 482/329
2: 463/309
1: 443/274
Curves as per ISO 2548C
1 23
4
12
34
12
34
4
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
41SNWRev.4, 15.05.2002
SNW 500--51550 Hzn = 960 1/min
Technical Data and DimensionsMounting arrangement CD
Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15
Drive coupling size 2) B 280 B 250 B 225 B 200
P/n Drive coupling 0,41 0,29 0,21 0,14
Thrust bearing size 7222 B.UA 7220 B.UA 4)
7222 B.UA 5)
h 4 min 1180 1084
h 4 max3) 2750 2552
Bearing arrangement t5max3) J t5max
3) J t5max3) J
3 3160 1,77 2960 1,69
4K 3850 1,77 3650 1,69
4 5430 1,77 5040 1,69
5K 6120 1,77 5720 1,69
5 7700 1,77 7110 1,69
6K -- -- 7700 1,69
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=960 1/min, 50 Hz; for n=875 1/min, 60 Hz, multiply figures by 1,054) Up to t5 max = 5040 mm5) Up to t5 max = 7770 mm
Mounting arrangement EBn / EBd
Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15
Drive coupling size 2) B 280 B 250 B 225 B 200
P/n Drive coupling 0,41 0,29 0,21 0,14
Thrust bearing size 7222 B.UA 7220 B.UA 4)
7222 B.UA 5)
Bearing arrangement ETmax3) J ETmax
3) J ETmax3) J
2 2450 1,80 2250 1,70
3K 3320 1,80 3120 1,70
3 4710 1,80 4320 1,70
4K 5580 1,80 5180 1,70
4 6990 1,80 6390 1,70
5K 7850 1,80 7250 1,70
5 9260 1,80 8460 1,70
6K 10120 1,80 9320 1,70
6 11530 1,80 10530 1,70
7K -- -- 11390 1,70
7 -- -- -- --all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=960 1/min, 50 Hz; for n=875 1/min, 60 Hz, multiply figures by 1,054) Up to ET max = 6390 mm5) Up to ET max = 11390 mm
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EBn
SNWType Series Booklet
42 SNWRev.4, 15.05.2002
SNW 500--62050 Hzn = 980 1/min
ClosedImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 150 300 450 600 750 900
H--St [m]
10
20
30
40
50
60
70
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
6
8
10
12
14
P [kW]
100
200
300
400
NR : D2A/ D2I[mm]
4 : 610/ 5703 : 585/ 5312 : 562/ 4951 : 540/ 462
Rho = 1000 [kg/m3] n = 980 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 610/ 5703 : 585/ 5312 : 562/ 4951 : 540/ 462
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
H--St [m]
SNWType Series Booklet
43SNWRev.4, 15.05.2002
SNW 500--62060 Hzn = 875 1/min
ClosedImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Bearing arrangement
Mounting arrangement
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EKn
SNWType Series Booklet
44 SNWRev.4, 15.05.2002
SNW 500--62050 Hzn = 980 1/min
Technical Data and DimensionsMounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70 60
P/n shaft (mat comb 01) 0,72 0,46 0,28
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280 B 280 B 250
7 -- -- -- -- -- --all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=980 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 0,914) Up to t5 max = 3290 mm5) Up to t5 max = 5740 mm
7 -- -- -- -- -- --all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=980 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 0,914) Up to ET max = 2730 mm, 5) Up to ET max = 7960 mm, 6) Up to ET max = 5010 mm7) Up to ET max = 9900 mm, 8) Up to ET max = 3250 mm, 9) Up to ET max = 11460 mm
SNWType Series Booklet
45SNWRev.4, 15.05.2002
SNW 600--53550 Hzn = 980 1/min
OpenImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 200 400 600 800 1000 1200
H--St [m]
0
4
8
12
16
20
24
28
32
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
8
10
12
14
P [kW]
0
100
200
300
NR : D2A/ D2I[mm]
4 : 531/ 4093 : 520/ 3842 : 504/ 3431 : 485/ 301
Rho = 1000 [kg/m3] n = 980 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 531/ 4093 : 520/ 3842 : 504/ 3431 : 485/ 301
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
46 SNWRev.4, 15.05.2002
SNW 600--53560 Hzn = 880 1/min
OpenImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 200 400 600 800 1000 1200
H--St [m]
0
4
8
12
16
20
24
28
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
7
8
9
10
11
P [kW]
50
100
150
200
NR : D2A/ D2I[mm]
4 : 531/ 4093 : 520/ 3842 : 504/ 3431 : 485/ 301
Rho = 1000 [kg/m3] n = 880 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 531/ 4093 : 520/ 3842 : 504/ 3431 : 485/ 301
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
47SNWRev.4, 15.05.2002
SNW 600--53550 Hzn = 980 1/min
Technical Data and Dimensions
Mounting arrangement CD
Material combination 1) 01
Shaft diameter 70 60
P/n shaft (mat comb 01) 0,46 0,28
Drive coupling size 2) A 315 B 280 B 280 B 250
P/n Drive coupling 0,58 0,41 0,41 0,29
Thrust bearing size 7226 B.UA 7226 B.UA
h 4 min 1366 1252
h 4 max3) 2986 2822
Bearing arrangement t5max3) J t5max
3) J t5max3) J
3 3250 2,33 3050 2,26
4K 4040 2,33 3860 2,26
4 5700 2,33 5320 2,26
5K 6490 2,33 6130 2,26
5 -- -- 7590 2,26
6K -- -- -- --
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06
Mounting arrangement EKn / EKd
Material combination 1) 01
Shaft diameter 70 60
P/n shaft (mat comb 01) 0,46 0,28
Drive coupling size 2) A 315 B 280 B 280 B 250
P/n Drive coupling 0,58 0,41 0,41 0,29
Thrust bearing size 7226 B.UA 7226 B.UA
Bearing arrangement ETmax3) J ETmax
3) J ETmax3) J
2 2410 2,39 2230 2,29
3K 3410 2,39 3230 2,29
3 4870 2,39 4500 2,29
4K 5840 2,39 5480 2,29
4 7300 2,39 6750 2,29
5K 8310 2,39 7760 2,29
5 9770 2,39 9020 2,29
6K 10730 2,39 10030 2,29
6 -- -- 11290 2,29
7K -- -- -- -- -- --
7 -- -- -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EKn
SNWType Series Booklet
48 SNWRev.4, 15.05.2002
SNW 600--55050 Hzn = 980 1/min
OpenImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 200 400 600 800 1000 1200
H--St [m]
5
10
15
20
25
30
35
40
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
10.0
12.5
15.0
17.5
20.0
22.5
P [kW]
150
200
250
300
NR : D2A/ D2I[mm]
4 : 557/ 4833 : 543/ 4522 : 534/ 4331 : 513/ 388
Rho = 1000 [kg/m3] n = 980 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 557/ 4833 : 543/ 4522 : 534/ 4331 : 513/ 388
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
49SNWRev.4, 15.05.2002
SNW 600--55060 Hzn = 880 1/min
OpenImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 160 320 480 640 800 960
H--St [m]
4
8
12
16
20
24
28
32
36
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
8
10
12
14
16
P [kW]
80
120
160
200
NR : D2A/ D2I[mm]
4 : 557/ 4833 : 543/ 4522 : 534/ 4331 : 513/ 388
Rho = 1000 [kg/m3] n = 880 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 557/ 4833 : 543/ 4522 : 534/ 4331 : 513/ 388
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
50 SNWRev.4, 15.05.2002
SNW 600--55050 Hzn = 980 1/min
Technical Data and Dimensions
Mounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70 60
P/n shaft (mat comb 01) 0,72 0,46 0,28
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280 B 280 B 250
7 -- -- -- -- -- --all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06
Mounting arrangement EKn / EKd
Material combination 1) 01
Shaft diameter 80 70 60
P/n shaft (mat comb 01) 0,72 0,46 0,28
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280 B 280 B 250
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,064) Up to ET max = 3440 mm, 5) Up to ET max = 9810 mm, 6) Up to ET max = 10770 mm7) Lubrication intervals and quantities see page 13
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EKn
SNWType Series Booklet
51SNWRev.4, 15.05.2002
SNW 600--57550 Hzn = 960 1/min
Open Impeller
A = EB 7 ; EB 7KB = CD 7 ; CD 7K ; EB 6; EB 6KC = CD 6 ; CD 6K ; EB 5; EB 5KD = CD 5 ; CD 5K ; EB 4; EB 4KE = CD 4 ; CD 4K ; EB 3; EB 3KF = CD 3 ; EB 2Typical Pump Designation:--EB 5K
Q [l/s]0 200 400 600 800 1000 1200
H--St [m]
8
12
16
20
24
28
32
36
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
6
8
10
12
14
P [kW]
150
200
250
300
NR : D2A/ D2I[mm]
3 : 547/ 4292 : 535/ 3931 : 524/ 356
Rho = 1000 [kg/m3] n = 960 [1/min]
1
1
1
1
2
2
2
3
3
3
3
Qmin
NR : D2A/ D2I[mm]
3 : 547/ 4292 : 535/ 3931 : 524/ 356
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
52 SNWRev.4, 15.05.2002
SNW 600--57560 Hzn = 875 1/min
OpenImpeller
A = EB 7 ; EB 7KB = CD 7 ; CD 7K ; EB 6; EB 6KC = CD 6 ; CD 6K ; EB 5; EB 5KD = CD 5 ; CD 5K ; EB 4; EB 4KE = CD 4 ; CD 4K ; EB 3; EB 3KF = CD 3 ; EB 2Typical Pump Designation:--EB 5K
Q [l/s]0 200 400 600 800 1000 1200
H--St [m]
5
10
15
20
25
30
35
40
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
6
7
8
9
10
11
P [kW]
100
150
200
250
NR : D2A/ D2I[mm]
3 : 547/ 4292 : 535/ 3931 : 524/ 356
Rho = 1000 [kg/m3] n = 875 [1/min]
1
1
1
1
2
2
2
3
3
3
3
Qmin
NR : D2A/ D2I[mm]
3 : 547/ 4292 : 535/ 3931 : 524/ 356
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
53SNWRev.4, 15.05.2002
SNW 600--57550 Hzn = 960 1/min
Technical Data and DimensionsMounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70 60
P/n shaft (mat comb 01) 0,72 0,46 0,28
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280 B 280 B 250
7 -- -- -- -- -- --all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=960 1/min, 50 Hz; for n=875 1/min, 60 Hz, multiply figures by 1,054) Up to t5 max = 6335 mm, 5) Up to t5 max = 7795 mm
Mounting arrangement EBn / EBd
Material combination 1) 01
Shaft diameter 80 70 60
P/n shaft (mat comb 01) 0,72 0,46 0,28
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280 B 280 B 250
7 -- -- -- -- -- --all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=960 1/min, 50 Hz; for n=875 1/min, 60 Hz, multiply figures by 1,054) Up to ET max = 3610 mm, 5) Up to ET max = 8520 mm, 6) Up to ET max = 10940 mm7) Up to ET max = 7970 mm, 8) Up to ET max = 11500 mm
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EBn
SNWType Series Booklet
54 SNWRev.4, 15.05.2002
SNW 600--60050 Hzn = 980 1/min
OpenImpeller
A = EB 7 ; EB 7KB = CD 7 ; CD 7K ; EB 6; EB 6KC = CD 6 ; CD 6K ; EB 5; EB 5KD = CD 5 ; CD 5K ; EB 4; EB 4KE = CD 4 ; CD 4K ; EB 3; EB 3KF = CD 3 ; EB 2Typical Pump Designation:--EB 5K
Q [l/s]0 240 480 720 960 1200 1440
H--St [m]
5
10
15
20
25
30
35
40
45
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
10
15
20
25
30
P [kW]
100
200
300
400
NR : D2A/ D2I[mm]
4 : 605/ 5253 : 583/ 4812 : 561/ 4331 : 536/ 375
Rho = 1000 [kg/m3] n = 980 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 605/ 5253 : 583/ 4812 : 561/ 4331 : 536/ 375
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
55SNWRev.4, 15.05.2002
SNW 600--60060 Hzn = 880 1/min
OpenImpeller
A = EB 7 ; EB 7KB = CD 7 ; CD 7K ; EB 6; EB 6KC = CD 6 ; CD 6K ; EB 5; EB 5KD = CD 5 ; CD 5K ; EB 4; EB 4KE = CD 4 ; CD 4K ; EB 3; EB 3KF = CD 3 ; EB 2Typical Pump Designation:--EB 5K
Q [l/s]0 200 400 600 800 1000 1200
H--St [m]
5
10
15
20
25
30
35
40
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
8
12
16
20
P [kW]
150
200
250
300
NR : D2A/ D2I[mm]
4 : 605/ 5253 : 583/ 4812 : 561/ 4331 : 536/ 375
Rho = 1000 [kg/m3] n = 880 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 605/ 5253 : 583/ 4812 : 561/ 4331 : 536/ 375
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
56 SNWRev.4, 15.05.2002
SNW 600--60050 Hzn = 980 1/min
Technical Data and Dimensions
Mounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
Thrust bearing size 7334 B.UA 7334 B.UA
h 4 min 1511 1418
h 4 max3) 3206 3038
Bearing arrangement t5max3) J t5max
3) J t5max3) J
3 3490 5,61 3320 5,48
4K -- -- 4110 5,48
4 6110 5,61 5770 5,48
5K -- -- 6560 5,48
5 -- -- -- --
6K -- -- -- --
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06
Mounting arrangement EBn / EBd
Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
Thrust bearing size 7334 B.UA 6) 7330 B.UA 4)
7334 B.UA 5)
Bearing arrangement ETmax3) J ETmax
3) J ETmax3) J
2 2650 5,72 2480 5,54
3K -- -- 3480 5,54
3 5270 5,72 4940 5,54
4K -- -- 5910 5,54
4 7880 5,72 7370 5,54
5K -- -- 8380 5,54
5 10490 5,72 9840 5,54
6K -- -- 10800 5,54
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,064) Up to ET max = 2480 mm, 5) Up to ET max = 10800 mm
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EBn
SNWType Series Booklet
57SNWRev.4, 15.05.2002
SNW 600--65050 Hzn = 990 1/min
ClosedImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 200 400 600 800 1000 1200
H--St [m]
20
30
40
50
60
70
80
90
100
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
8
9
10
11
12
13
P [kW]
200
300
400
500
NR : D2A/ D2I[mm]
2 : 647/5931 : Dm=565
Rho = 1000 [kg/m3] n = 990 [1/min]
1
1
1
1
2
2
2
2
Qmin
NR : D2A/ D2I[mm]
2 :1 :
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
58 SNWRev.4, 15.05.2002
SNW 600--65060 Hzn = 875 1/min
ClosedImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 160 320 480 640 800 960
H--St [m]
15
20
25
30
35
40
45
50
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
6
7
8
9
10
11
P [kW]
200
250
300
350
NR : D2A/ D2I[mm]
2 :1
Rho = 1000 [kg/m3] n = 875 [1/min]
1
1
1
1
2
2
2
2
Qmin
NR : D2A/ D2I[mm]
2 : 647/ 5931 : Dm=565
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
59SNWRev.4, 15.05.2002
SNW 600--65050 Hzn = 990 1/min
Technical Data and Dimensions
Mounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
Thrust bearing size 2 x 7240 B.UA 2 x 7240 B.UA
h 4 min 1583 1451
h 4 max3) 3264 3065
Bearing arrangement t5max3) J t5max
3) J t5max3
)J
3 3610 9,14 3440 8,97
4K -- -- 4230 8,97
4 6230 9,14 5890 8,97
5K -- -- 6680 8,97
5 -- -- -- --
6K -- -- -- --
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=990 1/min, 50 Hz; for n=875 1/min, 60 Hz, multiply figures by 1,06
Mounting arrangement EKn / EKd
Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
Thrust bearing size 2 x 7240 B.UA 2 x 7240 B.UA
Bearing arrangement ETmax3) J ETmax
3) J ETmax3) J
2 2770 9,31 2600 9,05
3K -- -- 3600 9,05
3 5390 9,31 5060 9,05
4K -- -- 6030 9,05
4 8000 9,31 7490 9,05
5K -- -- 8500 9,05
5 10610 9,31 9960 9,05
6K -- -- 10920 9,05
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=990 1/min, 50 Hz; for n=875 1/min, 60 Hz, multiply figures by 1,06
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EKn
SNWType Series Booklet
60 SNWRev.4, 15.05.2002
SNW 600--70050 Hzn = 980 1/min
ClosedImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
61SNWRev.4, 15.05.2002
SNW 600--70060 Hzn = 880 1/min
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
62 SNWRev.4, 15.05.2002
SNW 600--70050 Hzn = 980 1/min
Technical Data and Dimensions
Mounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
Thrust bearing size 2 x 7240 B.UA 2 x 7240 B.UA
h 4 min 1583 1451
h 4 max3) 3264 3065
Bearing arrangement t5max3) J t5max
3) J t5max3) J
3 3610 16,5 3440 14,77
4K -- -- 4230 14,77
4 6230 16,5 5890 14,77
5K -- -- 6680 14,77
5 -- -- -- --
6K -- -- -- --
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06
Mounting arrangement EKn / EKd
Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
Thrust bearing size 2 x 7240 B.UA 2 x 7240 B.UA
Bearing arrangement ETmax3) J ETmax
3) J ETmax3) J
2 2770 16,7 2600 14,8
3K -- -- 3600 14,8
3 5390 16,7 5060 14,8
4K -- -- 6030 14,8
4 8000 16,7 7490 14,8
5K -- -- 8500 14,8
5 10610 16,7 9960 14,8
6K -- -- 10920 14,8
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EKn
SNWType Series Booklet
63SNWRev.4, 15.05.2002
SNW 600--72050 Hzn = 980 1/min
ClosedImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
64 SNWRev.4, 15.05.2002
SNW 600--72060 Hzn = 880 1/min
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
65SNWRev.4, 15.05.2002
SNW 600--72050 Hzn = 980 1/min
Technical Data and Dimensions
Mounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
Thrust bearing size 2 x 7240 B.UA 2 x 7240 B.UA
h 4 min 1583 1451
h 4 max3) 3264 3065
Bearing arrangement t5max3) J t5max
3) J t5max3) J
3 3610 17,4 3440 15,7
4K -- -- 4230 15,7
4 6230 17,4 5890 15,7
5K -- -- 6680 15,7
5 -- -- -- --
6K -- -- -- --
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06
Mounting arrangement EKn / EKd
Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
Thrust bearing size 2 x 7240 B.UA 2 x 7240 B.UA
Bearing arrangement ETmax3) J ETmax
3) J ETmax3) J
2 2770 17,9 2600 16,2
3K -- -- 3600 16,2
3 5390 17,9 5060 16,2
4K -- -- 6030 16,2
4 8000 17,9 7490 16,2
5K -- -- 8500 16,2
5 10610 17,9 9960 16,2
6K -- -- 10920 16,2
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EKn
SNWType Series Booklet
66 SNWRev.4, 15.05.2002
SNW 700--65550 Hzn = 735 1/min
OpenImpeller
A = EB 7 ; EB 7KB = CD 7 ; CD 7K ; EB 6; EB 6KC = CD 6 ; CD 6K ; EB 5; EB 5KD = CD 5 ; CD 5K ; EB 4; EB 4KE = CD 4 ; CD 4K ; EB 3; EB 3KF = CD 3 ; EB 2Typical Pump Designation:--EB 5K
Q [l/s]0 300 600 900 1200 1500 1800
H--St [m]
0
5
10
15
20
25
30
35
40
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
8
10
12
14
16
P [kW]
0
150
300
450
NR : D2A/ D2I[mm]
4 : 704/ 4863 : 689/ 4672 : 675/ 4401 : 656/ 404
Rho = 1000 [kg/m3] n = 735 [1/min]
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 704/ 4863 : 689/ 4672 : 675/ 4401 : 656/ 404
1
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
67SNWRev.4, 15.05.2002
SNW 700--65560 Hzn = 710 1/min
OpenImpeller
A = EB 7 ; EB 7KB = CD 7 ; CD 7K ; EB 6; EB 6KC = CD 6 ; CD 6K ; EB 5; EB 5KD = CD 5 ; CD 5K ; EB 4; EB 4KE = CD 4 ; CD 4K ; EB 3; EB 3KF = CD 3 ; EB 2Typical Pump Designation:--EB 5K
Q [l/s]0 300 600 900 1200 1500 1800
H--St [m]
0
5
10
15
20
25
30
35
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
6
8
10
12
14
P [kW]
100
200
300
400
NR : D2A/ D2I[mm]
4 : 704/ 4863 : 689/ 4672 : 675/ 4401 : 656/ 404
Rho = 1000 [kg/m3] n = 710 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 704/ 4863 : 689/ 4672 : 675/ 4401 : 656/ 404
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
68 SNWRev.4, 15.05.2002
SNW 700--65550 Hzn = 735 1/min
Technical Data and DimensionsMounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
Thrust bearing size 7328 B.UA 4)
7330 B.UA 5)
7328 B.UA
h 4 min 1553 1435
h 4 max3) 3648 3429
Bearing arrangement t5max3) J t5max
3) J t5max3) J
3 4310 8,70 4120 8,57
4K 5250 8,70 5060 8,57
4 -- ---- 6940 8,57
5K -- -- -- --
5 -- -- -- --
6K -- -- -- --
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --all dimensions in mm, mass moment of inertia J in kgm2,1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=735 1/min, 50 Hz; for n=710 1/min, 60 Hz, multiply figures by 1,024) Up to t5 max = 4310 mm, 5) Up to t5 max = 5250 mm
Mounting arrangement EBn / EBd
Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
Thrust bearing size 7328 B.UA 4)
7330 B.UA 5)7328 B.UA 6)
7330 B.UA 7)
Bearing arrangement ETmax3) J ETmax
3) J ETmax3) J
2 3390 8,83 3190 8,64
3K 4510 8,83 4320 8,64
3 6410 8,83 6020 8,64
4K 7520 8,83 7130 8,64
4 9430 8,83 8840 8,64
5K 10540 8,83 9950 8,64
5 -- -- 11660 8,64
6K -- -- -- 8,64
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=735 1/min, 50 Hz; for n=710 1/min, 60 Hz, multiply figures by 1,024) Up to ET max = 6410 mm, 5) Up to ET max = 6410 mm, 6) Up to ET max = 9950 mm7) Up to ET max = 11660 mm
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EBn
SNWType Series Booklet
69SNWRev.4, 15.05.2002
SNW 700--71550 Hzn = 725 1/min
OpenImpeller
A = EB 7 ; EB 7KB = CD 7 ; CD 7K ; EB 6; EB 6KC = CD 6 ; CD 6K ; EB 5; EB 5KD = CD 5 ; CD 5K ; EB 4; EB 4KE = CD 4 ; CD 4K ; EB 3; EB 3KF = CD 3 ; EB 2Typical Pump Designation:--EB 5K
Q [l/s]0 250 500 750 1000 1250 1500
H--St [m]
4
8
12
16
20
24
28
32
36
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
7.5
10.0
12.5
15.0
17.5
P [kW]
200
250
300
350
NR : D2A/ D2I[mm]
4 : 704/ 6063 : 681/ 5482 : 654/ 4831 : 633/ 419
Rho = 1000 [kg/m3] n = 725 [1/min]
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 704/ 6063 : 681/ 5482 : 654/ 4831 : 633/ 419
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
70 SNWRev.4, 15.05.2002
SNW 700--71560 Hzn = 700 1/min
OpenImpeller
A = EB 7 ; EB 7KB = CD 7 ; CD 7K ; EB 6; EB 6KC = CD 6 ; CD 6K ; EB 5; EB 5KD = CD 5 ; CD 5K ; EB 4; EB 4KE = CD 4 ; CD 4K ; EB 3; EB 3KF = CD 3 ; EB 2Typical Pump Designation:--EB 5K
Q [l/s]0 300 600 900 1200 1500 1800
H--St [m]
4
8
12
16
20
24
28
32
36
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
8
10
12
14
16
18
P [kW]
100
200
300
400
NR : D2A/ D2I[mm]
4 : 704/ 6063 : 681/ 5482 : 654/ 4831 : 633/ 419
Rho = 1000 [kg/m3] n = 700 [1/min]
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 704/ 6063 : 681/ 5482 : 654/ 4831 : 633/ 419
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
71SNWRev.4, 15.05.2002
SNW 700--71550 Hzn = 725 1/min
Technical Data and DimensionsMounting arrangement CD
Material combination 1) 01
Shaft diameter 100 90 80
P/n shaft (mat comb 01) 1,26 0,87 0,72
Drive coupling size 2) A 480 A 440 A 440 A 400 A 350 A 400 A 350 A 315
7 -- -- -- -- -- --all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=725 1/min, 50 Hz; for n=700 1/min, 60 Hz, multiply figures by 1,02
Mounting arrangement EBn / EBd
Material combination 1) 01
Shaft diameter 100 90 80
P/n shaft (mat comb 01) 1,26 0,72
Drive coupling size 2) A 480 A 440 A 440 A 400 A 350 A 400 A 350 A 315
all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=725 1/min, 50 Hz; for n=700 1/min, 60 Hz, multiply figures by 1,024) Up to ET max = 4550 mm, 5) Up to ET max = 11290 mm, 6) Up to ET max = 4380 mm7) Up to ET max = 10760 mm, 8) Up to ET max = 4190 mm, 9) Up to ET max = 10220 mm
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EBn
SNWType Series Booklet
72 SNWRev.4, 15.05.2002
SNW 700--75550 Hzn = 725 1/min
OpenImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 400 800 1200 1600 2000 2400
H--St [m]
0
8
16
24
32
40
48
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
8
10
12
14
16
P [kW]
0
200
400
600
NR : D2A/ D2I[mm]
4 : 776/ 6073 : 747/ 5522 : 717/ 4881 : 694/ 426
Rho = 1000 [kg/m3] n = 725 [1/min]
1
1
1
1
2
2
2
3
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 776/ 6073 : 747/ 5522 : 717/ 4881 : 694/ 426
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
73SNWRev.4, 15.05.2002
SNW 700--75560 Hzn = 700 1/min
OpenImpeller
A = EK 7 ; EK 7KB = CD 7 ; CD 7K ; EK 6; EK 6KC = CD 6 ; CD 6K ; EB 5; EK 5KD = CD 5 ; CD 5K ; EB 4; EK 4KE = CD 4 ; CD 4K ; EB 3; EK 3KF = CD 3 ; EK 2Typical Pump Designation:--EK 5K
Q [l/s]0 400 800 1200 1600 2000 2400
H--St [m]
0
5
10
15
20
25
30
35
40
Eta--St [%]
10
20
30
40
50
60
70
80
90
NPSH [m]
6
8
10
12
14
P [kW]
0
200
400
600
NR : D2A/ D2I[mm]
4 : 776/ 6073 : 746/ 5522 : 717/ 4881 : 694/ 426
Rho = 1000 [kg/m3] n = 700 [1/min]
1
1
1
1
2
2
2
3
3
4
4
4
4
Qmin
NR : D2A/ D2I[mm]
4 : 776/ 6073 : 746/ 5522 : 717/ 4881 : 694/ 426
3
Curves as per ISO 2548C
Bearing arrangement
Mounting arrangement
SNWType Series Booklet
74 SNWRev.4, 15.05.2002
SNW 700--75550 Hzn = 725 1/min
Technical Data and DimensionsMounting arrangement CD
Material combination 1) 01
Shaft diameter 100 90 80
P/n shaft (mat comb 01) 1,26 0,87 0,72
Drive coupling size 2) A 480 A 440 A 440 A 400 A 350 A 400 A 350 A 315
7 -- -- -- -- -- --all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=725 1/min, 50 Hz; for n=700 1/min, 60 Hz, multiply figures by 1,024) Up to t5 max = 4580 mm, 5) Up to t5 max = 5520 mm
Mounting arrangement EKn / EKd
Material combination 1) 01
Shaft diameter 100 90 80
P/n shaft (mat comb 01) 1,26 0,87 0,72
Drive coupling size 2) A 480 A 440 A 440 A 400 A 350 A 400 A 350 A 315
7 -- -- -- -- -- --all dimensions in mm, mass moment of inertia J in kgm21) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,42) Drive coupling FLENDER N--EUPEX3) Figures are valid for n=725 1/min, 50 Hz; for n=700 1/min, 60 Hz, multiply figures by 1,024) Up to ET max = 4780 mm, 5) Up to ET max = 7040 mm, 6) Up to ET max = 11520 mm, 7) Up to ET max = 4610 mm,8) Up to ET max = 9880mm, 9) Up to ET max = 10990 mm, 10) Up to ET max = 6320 mm, 11) Up to ET max = 10450 mm
ET
ET
t5
h4
Mounting arrangement CD
Mounting arrangement EKn
SNWType Series Booklet
75SNWRev.4, 15.05.2002
Recommended Spare Partsfor five year’s operation
No. of pumps including stand--by pumps
Part No. Part designation 2 3 4 5 6 8 10 and aboveg
No. of spare parts
233 Impeller 1 1 1 2 2 3 30 %
211, 212,213, 86--2 etc
Shafting with keys,screws etc, and shaft coupling 1 1 1 2 2 3 30 %