Page 1
.com
Success in ExportingSuccess in Exporting
ONEIA – Expanding Beyond Ontario: ONEIA – Expanding Beyond Ontario: Traditional & New Technologies in Canada Traditional & New Technologies in Canada
& Abroad & Abroad
Brian Butters, P.Eng., MBA - PresidentBrian Butters, P.Eng., MBA - President
March 3, 2011March 3, 2011
Page 2
.com
Licensed Engineering FirmLicensed Engineering Firm
Provide Unique Solutions Provide Unique Solutions to Purify, Condition, & Control Waterto Purify, Condition, & Control Water
for Economic & Environmental Advantagefor Economic & Environmental Advantage
Inc 1993Inc 1993
Page 3
.com
Exports by:Exports by:
Location:• US – FL, MD, CA, NC, AK, NV, AZ, TX, NH, IL• Australia, Bahrain, France, Japan, Korea• Canada – ON, NB, NS, AB
Value:• USA – 75%• Offshore – 15%• Canada – 10%
Page 4
.com
ON Brownfield SoldON Brownfield Sold
Page 5
.com
Global Success FactorsGlobal Success Factors
• Unique Technology & BenefitsUnique Technology & Benefits• Complexity ReductionComplexity Reduction• Fully Integrated Packaged SolutionFully Integrated Packaged Solution• Design Out RiskDesign Out Risk
• Dispel Myths/Reduce RiskDispel Myths/Reduce RiskPilotPilot
Page 6
.com
Unique TechnologiesUnique Technologies
Photo-Cat: Photo-Cat:
DeWRS:DeWRS:
CFFeR:CFFeR:OILS:OILS:PET:PET:
AOP+, Multi Barrier, NSF61AOP+, Multi Barrier, NSF61Dewatering & Water Reuse Dewatering & Water Reuse
Ceramic Membrane SystemCeramic Membrane SystemChemical Free Fe RemovalChemical Free Fe RemovalOil In-Line SeparationOil In-Line SeparationPhase Extraction TechnologyPhase Extraction Technology
Benefits:• Chem & Waste Free• Recovery & Reuse• Low Capex & Opex
Page 7
.com
Complexity ReductionComplexity ReductionConventional/RejectedConventional/Rejected
Building Requirement
Static Mixer Floc Tank
Static Mixer Floc Tank
Clarifier
Clarifier
Transfer Tank
Transfer Tank
Filtration Organo Clay
GAC
Filtration Organo Clay
GAC
Vapour Carbon
Floc Storage
High Volume / Low BTU
Municipal Discharge
Well
PHOTO-CAT/InstalledPHOTO-CAT/Installed
Filtration
Low Volume / High BTU
Municipal Discharge
PHOTO-CAT
NAPL Storage
Well
Building Requirement
Page 8
.com
Building Requirement
Conventional SolventConventional Solvent
Well #2
Sanitary Discharge
Well #3
Well #1
Surge Tank Filtration Oil Coalescor GAC
Filtration
Filtration
Oil Coalescor
Oil Coalescor GAC
Air Stripper
Building
RequirementWell #2
PHOTO-CATSurface Water Discharge
Well #3
Well #1
PHOTO-CATPHOTO-CAT
Complexity ReductionComplexity Reduction
Page 9
.com
Complexity ReductionComplexity Reduction
Conventional UV/OxConventional UV/Ox
Building Requirement
Flocculation Coagulation Clarifier 38kW UV/Ox
Filter Press Solid Waste
Sanitary Discharge
Alum Polymer
H2O2
Well
Surface Water Discharge
PHOTO-CAT SolutionPHOTO-CAT Solution
Well
14kW
PHOTO-CAT
Building
Page 10
.com
Building Requirement
Conventional Ozone/PeroxideConventional Ozone/Peroxide
Precipitation Clarifier Ozone
Filter Press Solid Waste
Discharge
NaOH
H2O2
Wells
H2SO4
O2 Gen
Complexity ReductionComplexity Reduction
Discharge
PHOTO-CAT/CFFeR SolutionPHOTO-CAT/CFFeR Solution
Wells
PHOTO-CAT
Building Eliminated
CFFeR
Solid Waste
Page 11
.com
L/min to Multi MGDL/min to Multi MGD
Page 12
.com
Motco-Superfund Site, TXMotco-Superfund Site, TX
Page 13
.com
Pollution Free Plant, MDPollution Free Plant, MD
Page 14
.com
Oil/Water Separation, ABOil/Water Separation, AB
Page 15
.com
1,4-Dioxane, Sarasota FL1,4-Dioxane, Sarasota FL
Page 16
.com
Landfill/RCRA Site, NCLandfill/RCRA Site, NC
Page 17
.com
NC - PilotNC - Pilot
Page 18
.com
NC - Pilot EquipmentNC - Pilot Equipment
Page 19
.com
NC - Water Quality: Influent & Post NC - Water Quality: Influent & Post
Influent Influent Effluent Effluent
Effluent Tank Effluent Tank
Looking Down into Effluent TankLooking Down into Effluent Tank
Page 20
.com
NC – Chemical Free Iron/Mn RemovalNC – Chemical Free Iron/Mn Removal
• Lower volume, dense and is easily decantedLower volume, dense and is easily decanted
Tank with Oxidized Fe & Mn Settled
Water Line
Settled Mn & Fe
Fe Oxidation Only Fe & Mn Oxidation
Page 21
.com
NC - PHOTO-CAT System PerformanceNC - PHOTO-CAT System Performance
ParameterParameter InfluentInfluent EffluentEffluent1,4-Dioxane1,4-Dioxane 3050 ug/L3050 ug/L NDND1,1,1-TCA1,1,1-TCA 935 ug/L935 ug/L NDND1,1-DCA1,1-DCA 1990 ug/L1990 ug/L NDND1,1-DCE1,1-DCE 745 ug/L745 ug/L NDND1,2-DCA1,2-DCA 95.3 ug/L95.3 ug/L NDNDBenzeneBenzene 88.1 ug/L88.1 ug/L NDNDChlorobenzeneChlorobenzene 3210 ug/L3210 ug/L NDNDChloroethaneChloroethane 445 ug/L445 ug/L NDNDCis-1,2-DCECis-1,2-DCE 3880 ug/L3880 ug/L NDNDMethylene ChlorideMethylene Chloride 2540 ug/L2540 ug/L NDNDTolueneToluene 188 ug/L188 ug/L NDNDVinyl ChlorideVinyl Chloride 508 ug/L508 ug/L NDNDXyleneXylene 75.1 ug/L75.1 ug/L NDNDFeFe 5900 ug/L5900 ug/L NDNDMnMn 8300 ug/L8300 ug/L NDNDFlow Rate = 50 gpmFlow Rate = 50 gpm
Page 22
.com
Contract Award Contract Award Contract ExpansionContract ExpansionContract Expansion – Contract Expansion – Irrigation ControlsIrrigation ControlsContract Expansion – Contract Expansion – Phyto ControlsPhyto Controls
Page 23
.com
Contact UsContact Us
Brian Butters, P.Eng., MBABrian Butters, P.Eng., MBAPresidentPresident
[email protected] @purifics.com