MODEL 1010 Ideal for Upgrading Domestic Services FEATURES INCLUDE BK-G6 Module Capacity 10m 3 /h (Gas) at 125 Pascal Loss Low Pressure Drop Powder coated aluminium case Pulse Ready Magnetically Driven, All Weather, Sealed Index Designed to EN1359 & AG702 MODEL 1010 Large Domestic Light Commercial A M P Y E M A I L M E T E R I N G
2
Embed
OK PROCEED TO PRINT OK WITH AMENDMENTS Large Domestic …
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
MODEL
1010Ideal for UpgradingDomestic Services
FEATURES INCLUDE
BK-G6 Module
Capacity 10 m3/h(Gas)at 125 Pascal Loss
Low Pressure Drop
Powder coatedaluminium case
Pulse Ready
Magnetically Driven, All Weather, Sealed Index
Designed to EN1359 & AG702
MODEL1010
Large DomesticLight Commercial
A M P Y E M A I L M E T E R I N GCLIENT APPROVAL
OK PROCEED TO PRINT
OK WITH AMENDMENTS
AS MARKED THEN
PROCEED TO PRINT
PLEASE PROVIDE NEW
PROOF FOR APPROVAL
SIGNATURE
DATE • •
JOB No. 3640EMA
DATE 12 • 4 • 05
DRAFT No. 2
FRA
GIL
E D
ESIG
N
PH
03
9525
041
1
FAX
03
9521
542
0
General Details
The Model 1010 is designed for large domestic or light commercial applications.
Utilising the compact BK-G6 module it provides a designed capacity of 10 m3/hof natural gas at 125 Pa pressure drop (Natural Gas specific gravity 0.62).
Construction
The Model 1010 is designed for extreme weather conditions having a fullysealed hydrophilic coated UV stabilised index, die cast aluminium housingwhich is Alodine surface pre-treated followed by baked Woodland Greypolyester powder coat.
Easy Installation
The meters inlet / outlet bosses and external dimensions are identical to thatof the Model 750. While delivering an increased flow channel performance viathe BK-G6 module the Model 1010 meter weighs just 100 grams (100g) morethan the Model 750. This allows domestic gas services to be upgraded to ahigher flow capacity without the need to alter the pipe-work at the meter,saving time and money.
Accuracy
The outstanding design features of the Model 1010 gas meter such as thetangent control, large cyclic capacity and magnetic drive index provideunparalleled accuracy. Our calibration and test facilities are accredited toISO/IEC 17025.
Accuracy Retention
The initial accuracy of a meter is easy to achieve by using calibration to passinitial testing. However, sustained accuracy over time comes down to thequality, design and construction of the meter. The Model 1010 has beendesigned for long-term stability and extended field life.
Des
ign:
ww
w.fr
agile
desi
gn.c
om.a
u 3
640
Large Domestic, Light Commercial
SPECIFICATIONS*
Gases
Natural gas, town gas,propane, butane, LPG andinert gases. For other gasesplease consult AMPY EmailMetering.
Anti –Fog hydrophilic coated 8 digit index 5 whole cubicmeters (white numbers on blackwheels) and 3 decimal places(white numbers on red wheels).
Threads
Meter boss threads verticalinlet/outlet 10 Light 1" toBS746 1987 at 152mm ( 6" )centres. 1" 10 Lt. to 3/4" BSPCap Nut and Liner setavailable (part number SK5).
Case Construction
Pressure die cast aluminium.
Pulse Output Ready
All meters are fitted with amagnet in the first index wheeland hence each meter is easilypulse retro fittable in the field1 pulse / 10 lts.
Corrosion Protection
Alodine internal and externalpre-treatment of castingsfollowed by baked WoodlandGrey polyester powder coatfor maximum corrosionprotection.
Pulse Output Module
10 litres per pulse using IN-Z61 or IN-Z62 pulsemodule.
Emwest Products Pty Limitedtrading as AMPY Email Metering
ABN 78 002 894 224
*Continuing product improvement is AMPY Email Metering policy, specifications are subject tochange without notice.
Endurance Testing
Endurance testing to the most stringent worldrequirements has been conducted on the Model1010 demonstrating long term accuracy retention.
The Model 1010 meter exceeds the endurancetesting requirements of the European StandardEN1359:1999, American National Standard ANSIB109.1, Australian Gas Association AG702, andOMIL Recommendation 31.