264 NV/NH 00 001692700 HVL 00 3-p M8-M8 0,72 1/1 1 001692705 HVL 1 3-p M10-M10 2,5 1/1 2 001692570 HVL 2 3-p M10-M10 3,1 1/1 3 001692580 HVL 3 3-pM10-M10 4,8 1/1 4a 001692620 HVL 4a 3-p M16 1250 15,7 1/1 4a 001692630 HVL 4a 3-p M16 1600 15,7 1/1 558 NV disconnectors with fuses Description Horizontal fuse-switch disconnector type HVL are designed to be used in most demanding fields of use such as power distribution, industry and many other applications where maximum quality and switching capability is needed. Main purpose of horizontal fuse-switch disconnector type HVL in combination with NV fuse-links (with characteristics that meet correspond protection level) is to protect equipment and ca- bles against overloads and short circuits. Wide range of disconnectors are designed to be used in combina- tion with fuse-links sizes 00, 1, 2, 3 and 4a which are suitable for mounting on mounting plate, DIN rails and on busbar system. As standard are at disposal 1, 2, 3 and 4-pole versions. Fields of use and features Horizontal fuse-switch disconnectors are designed for use in the most demanding applications that require disconnection function. They are suitable for challenging the scope of the external electrical junction boxes, and public lighting, security cable branches in industrial applications and for the separation of dis- tribution metering cabinets. The program of horizontal fuse-switch disconnectors type HVL offers a wide range of different connections allowing great flexibility in use. At disposal is a wide range of accessories which highly increase functionali- ties. Horizontal fuse-switch disconnectors HVL meet the requirements of the following standards: IEC 60947-1:2007 +A1:2010 IEC 60947-3:2008 EN 60947-1:2011 EN 60947-3:2009 VDE 0660-100:2011 VDE 0660-107:2010 Horizontal fuse-switch disconnector type HVL size 00, 1, 2, 3 and 4a 3-pole Size Code No. Type Weight [kg] Packaging [pcs] * see also table of accessories for HVL NV disconnectors with fuses technical data on page
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Fields of use and features Horizontalfuse-switchdisconnectorsaredesignedforuseinthemostdemandingapplicationsthatrequiredisconnectionfunction.Theyaresuitableforchallengingthescopeoftheexternalelectricaljunctionboxes,andpubliclighting,securitycablebranchesinindustrialapplicationsandfortheseparationofdis-tributionmeteringcabinets.
Fields of use and features Busbarsystemsareusedwhereverwewanttoachievehighvisibilityandcompactinsideelectricalcabinetswithoutundueadditionalwiring.Busbarsystemcanbeusedincasesofalterationorextensionofexistingelectricalcabinetsbecausethemorecompactsystemsavesspace,ortheonlywaytoensureenough.Asarule,thebusbarsystemsareusedinindustrialenvironments,wherethestructureofelectricalcabinetsmadebyfunctionalblockandwhereitshouldbeensuredhighvisibilityelectricalcomponentsforeaseandspeedofservicingintheeventoffailuresanddowntime.
Supports and connections (60mm busbar)Type Code No. Description Packaging
[pcs]1-pole busbar support for busbars 5-10mm and 20mm or 30mm width3-pole busbar support for busbars 5-10mm and 20mm or 30mm width4-pole busbar support for busbars 5-10mm and 20mm or 30mm width3-pole busbar support for busbars 5-10mm and 20mm or 30mm width with 25mm2 terminals
3-pole busbar support for busbars 5-10mm and 20mm or 30mm width with 16mm2 terminals
Insertion for busbar height compensation, 5mm Lateral cover for busbar holder, 3pLateral cover for busbar holder, 4pSide cover for busbar holder (BBS-60/3-A), 3pBusbar cover (3-pole), covering range 27-50mm/pieceBusbar cover (4-pole), covering range 27-50mm/pieceBusbar cover (1-pole) for single busbar 5-10mm thick and 20mm wide, length 1m Busbar cover (1-pole) for single busbar 5-10mm thick and 30mm wide, length 1mConnecting module 250A, 3-pole, terminal 1,5 - 70mm2 connectionConnecting module 250A, 4-pole, terminal 1,5 - 70mm2 connectionConnecting module 250A, 3-pole, terminal 16 - 120mm2 connection using Cu cable or flat Cu busbar 5mm
Connecting module 250A, 3-pole, terminal 16 - 120mm2 connection using Cu cable or flat Cu busbar 10mm
Connecting module 630A, 3-pole, terminal 70 - 300mm2 connectionConnecting module 630A, 3-pole, terminal clamping range 11x21mm using flat Cu busbarConductor terminal with clamping range 1,5-16mm2 for busbar thickness 5mmConductor terminal with clamping range 1,5-35mm2 for busbar thickness 5mmConductor terminal with clamping range 1,5-50mm2 for busbar thickness 5mmConductor terminal with clamping range 16-70mm2 for busbar thickness 5mmConductor terminal with clamping range 16-120mm2 for busbar thickness 5mmConductor terminal with clamping range 16-185mm2 for busbar thickness 5mmConductor terminal with clamping range 1,5-16mm2 for busbar thickness 10mmConductor terminal with clamping range 1,5-35mm2 for busbar thickness 10mmConductor terminal with clamping range 1,5-50mm2 for busbar thickness 10mmConductor terminal with clamping range 16-70mm2 for busbar thickness 10mmConductor terminal with clamping range 16-120mm2 for busbar thickness 10mmConductor terminal with clamping range 16-185mm2 for busbar thickness 10mmPlate terminal for busbars up to 30mm width, clamping range 34x34x10mm Plate terminal for busbars up to 40mm width, clamping range 34x34x10mmPlate terminal for busbars up to 50mm width, clamping range 34x34x10mmUniversal cover of 3-pole busbars 5-10mm, covering width 144mm (ex. cover for conductor terminals type CT- …)
Universal cover of 3-pole busbars 5-10mm, covering width 84mm (ex. cover for conductor terminals type CT- …)
Busbar connector for range 20x5mm - 30x10mm
BBS-60/… can be adjusted to 20m or 30mm busbar width and 5-10 mm thickness.
NVdisconnectorswithfuses
technicaldataonpage
269
NV
/NH
PTV-B 00 3p M8 001696035 1
PTV-B 00 3p F57 001696036 1
PTV-B 1 3p M10 BOTTOM
001696037 1
PTV-B 1 3p M10 TOP 001696038 1
PTV-B 2 3p M10 BOTTOM
001696039 1
PTV-B 2 3p M10 TOP 001696040 1
HVL-B 000 3p F57-5 Slim
001696041 1
HVL-B 00 3p M8 001696042 1
HVL-B 00 3p F57 001696043 1
HVL-B 1 3p M10 TOP 001696044 1
HVL-B 1 3p M10 BOTTOM
001696045 1
HVL-B 2 3p M10 TOP 001696046 1
HVL-B 2 3p M10 BOTTOM
001696047 1
HVL-B 3 3p M10 TOP 001696048 1
HVL-B 3 3p M10 BOTTOM
001696049 1
PTV-B 00 …
HVL-B 000 …
HVL-B 00 …
568,570
NH fuse-switch disconnectors and fuse bases for 60mm busbarType Code No. Description Packaging
[pcs]NH fuse-base size 00, 3-pole, 5-10mm busbars, fuse-link protection cover, connection top or bottom, M8 connection
NH fuse-base size 00, 3-pole, 5-10mm busbars, fuse-link protection cover, connection top or bottom, F57 connection
* in fuse-switch disconnector HVL-B 000 can be used only fuses size 000 (00C)** protection covers are in the table of accessories*** connecting from top/bottom (read installation manual carefully to avoid wrong connection!)
D fuse-switch disconnector and fuse bases for 60mm busbarType Code No. Description Packaging
[pcs]Fuse-switch disconnector for fuses D02 CH-type fuse-switch disconnectorD02-type-fuse-bases 3-pole for adapter sleeve, width 27mmDII-type-fuse-bases 3-pole for adapter sleeve, width 45mmDIII-type-fuse-bases 3-pole for adapter sleeve, width 54mmDII type-fuse-bases 3-pole for fitting screw, width 45mmDII type-fuse-bases 3-pole for fitting screw, width 54mmProtection cover width 27mm, height 195mmProtection cover width 36mm, height 195mmProtection cover width 45mm, height 195mmProtection cover width 54mm, height 195mmProtection cover width 27mm, height 230mmProtection cover width 36mm, height 230mmProtection cover width 45mm, height 230mmProtection cover width 54mm, height 230mmSide protection cover width 195 (for C-PTV-B … /195)Side protection cover width 230 (za C-PTV-B … /230)Protection cover Protection cover for DVL and CHVL, TOP/BOTTOMReach-through protection, face top and bottom , 27mm widthReach-through protection, face top and bottom , 36mm widthReach-through protection, face top and bottom , 45mm widthReach-through protection, face top and bottom , 54mm widthOverreaching protection, face top and bottom, 27mm widthOverreaching protection, face top and bottom, 36mm widthOverreaching protection, face top and bottom, 45mm widthOverreaching protection, face top and bottom, 54mm width Reach-through protection lateral right and leftD-strips spacer moduleCompenssation piece for busbar thickness (to adapt busbar compo-nents to fit 10mm or 5mm busbar thickness)
*HA5 is compensation piece which is intent to use for adaptation for example fuse-bases or fuse-switch disconnec-tor from 10mm busbar thickness to 5mm busbar thickness. Each phase pole needs one compensation piece.** more information available in technical part of the catalogue
PRS 00 MB 1p 001696120 1PRS 1 MB 1p 001696121 1PRS 3 MB 1p 001696122 1PRS 00 B TOP 195 001696123 1PRS 00 B BOTTOM 195 001696124 1PRS 00 B TOP 230 001696125 1PRS 00 B BOTTOM 230 001696126 1PRS 1 B TOP 001696127 1PRS 1 B BOTTOM 001696128 1PRS 2 B TOP 001696129 1PRS 2 B BOTTOM 001696130 1H-PTV-B 00 001696131 3
PRS … MB 1p
PRS … B 195
PRS … B 230
578
MCCB adapter
H-PTV-B 00
Device adapters for 60 mm busbarType Code No. Description Packaging
[pcs]Device adapter with 1 mounting rail, 3-pole, 45mm width, 25ADevice adapter with 1 mounting rail, 3-pole, 54mm width, 32ADevice adapter with 1 mounting rail, 3-pole, 63mm width, 32ADevice adapter with 1 mounting rail, 3-pole, 72mm width, 32ADevice adapter with 1 mounting rail, 3-pole, 54mm width, 63ADevice adapter with 1 mounting rail, 3-pole, 63mm width, 63ADevice adapter with 1 mounting rail, 3-pole, 72mm width, 63ADevice adapter with 2 mounting rails, 3-pole, 45mm width, 25ADevice adapter with 2 mounting rails, 3-pole,108mm width, 32ADevice adapter with 2 mounting rails, 3-pole,54mm width, 32ADevice adapter with 2 mounting rails, 3-pole, 72mm width, 32ADevice adapter with 2 mounting rails, 3-pole, 81mm width, 32ADevice adapter with 2 mounting rails, 3-pole, 108mm width, 32ADevice adapter with 2 mounting rails, 3-pole, 54mm width, 63ADevice adapter with 2 mounting rails, 3-pole, 81mm width, 63AMounting rail for adapter 45mm width, 35mm railMounting rail for adapter 54mm width, 35mm railMounting rail for adapter 63mm width, 35mm railMounting rail for adapter 72mm width, 35mm railMounting rail for adapter 81mm width, 35mm railMounting rail for adapter 90mm width, 35mm railConnecting pieceWidth compensation (9mm)Mobile mounting rail 45mm widthMobile mounting rail 54mm widthMobile mounting rail 63mm widthAdapter module 45mm width (segment to lengthen adapter)Adapter module 54mm width (segment to lengthen adapter)Compensation piece for busbar thickness (to adapt busbar compo-nents to fit 10mm or 5mm busbar thickness)
Adapter for MCCBAdapter for MCCBAdapter for MCCBAdapter for MCCBAdapter for MCCBAdapter for MCCBAdapter for MCCBAdapter for MCCB
Accessories for 60mm busbar systemType Code No. Description Packaging
[pcs]Protective cover, 1-pole, size 00, top/bottomProtective cover, 1-pole, size 1, top/bottom Protective cover, 1-pole, size 3, top/bottom Protective cover, 3-pole, size 00, TOP, short (bottom to top length 195mm) Protective cover, 3-pole, size 00, BOTTOM, short (bottom to top length 195mm) Protective cover, 3-pole, size 00, TOP, wide (bottom to top length 230mm) Protective cover, 3-pole, size 00, BOTTOM, wide (bottom to top length 230mm) Protective cover, 3-pole, size 1, TOPProtective cover, 3-pole, size 1, BOTTOMProtective cover, 3-pole, size 2, TOPProtective cover, 3-pole, size 2, BOTTOMProtection cover for fuse in fuse base PTV-B 00
* protection covers PRS 00 B TOP/BOTTOM 230 / 195 correspond to PTV-B 00 and HVL-B 00** protection covers for fuse bases type PTV-B 1,2 are PRS 1,2 B TOP/BOTTOM je to res
NVdisconnectorswithfuses
technicaldataonpage
272
NV
/NH
HVL EK 000 3p M8 001701000 0,58 1HVL EK 000 3p OS00 6-16 001701001 0,52 1HVL EK 000 3p OS00 25-50 001701002 0,58 1HVL EK 000 3p P00 10-35 001701003 0,62 1HVL EK 000 3p P00 50-70 001701004 0,63 1HVL EK 000 3p P002 10-16 001701005 0,66 1HVL EK 000 3p P002 25-35 001701006 0,67 1
DescriptionHorizontalfuse-switchdisconnectortypeHVLEKisa lowvolt-agedevicethatprovidesswitchingofthecircuits,dependingon the voltage and use categories. The main purpose of HVLEK is installation of the NH fuses size 000 and 00, and protec-tionofequipmentfromtheharmfuleffectsofshortcircuitandoverload.IfinsteadofNHfusesNHseparatorsareinstalled,HVLEK provides disconnection function and meets all regulatoryrequirementsintheopenposition.
FieldsofuseandfeaturesHorizontalfuse-switchdisconnectorsaredesignedforuseinanumber of applications that require disconnection function.They are suitable for challenging the scope of the externalelectrical junction boxes, and public lighting, security cablebranchesinindustrialapplicationsandfortheseparationofdis-tributionmeteringcabinets.
In horizontal fuse-switch disconnector type HVL EK 000 onlyNH knife-blade fuse links size 000 (00C) could be used whileinhorizontalfuse-switchdisconnectortypeHVLEK00sizes00and 000 (00C) could be used. About additional warnings onproductsseetechnicalpartofthecatalogue.
* HVL EK 000 are ready for mounting on mounting plate or mounting on 35mm mounting rail without acces-sories** connections are described in table of connections for HVL EK 000 *** given Type connector for the HVL EK means same connectors on both sides of HVL EK**** different combinations of connections on both sides of the separator can be made with terminals that are available as accessories***** highest clamp that can be placed on top side is P002 25-35, and on bottom side P002 50
Examples:
NVdisconnectorswithfuses
technicaldataonpage
273
NV
/NH
579,581,582
HVL EK 000 1p M8 001701400 0,23 3HVL EK 000 1p OS00 6-16 001701401 0,22 3HVL EK 000 1p OS00 25-50 001701402 0,22 3HVL EK 000 1p P00 10-35 001701403 0,24 3HVL EK 000 1p P00 50-70 001701404 0,24 3HVL EK 000 1p P002 10-16 001701405 0,25 3HVL EK 000 1p P002 25-35 001701406 0,25 3
HVL EK 000 4p M8 001701420 0,82 1
HVL-B EK 000 3p M8 001701011 0,85 1HVL-B EK 000 3p BT00 10-70 001701012 0,88 1
HVL-P EK 000 3p M8 001701013 0,59 1HVL-P EK 000 3p OS00 6-50 001701014 0,53 1HVL-P EK 000 3p P00 10-70 001701015 0,59 1
* HVL EK 000 are ready for mounting on mounting plate or mounting on 35mm mounting rail without acces-sories** connections are described in table of connections for HVL EK 000*** two-pole design can be done using two single-pole**** highest clamp that can be placed on top side is P002 25-35, and on bottom side P002 50
* HVL EK 000 are ready for mounting on mounting plate or mounting on 35mm mounting rail without acces-sories ** connections are described in table of connections for HVL EK 000*** switching off neutral pole (N) same time as switching phase polarity**** highest clamp that can be placed on top side is P002 25-35, and on bottom side P002 50
* HVL-B EK 000 are ready for mounting on 60mm busbar system, 5-10 mm thick** connections are described in table of connections for HVL EK 000*** connector BT00 10-70 in combination with HVL-B EK have clamping cross-section up to 50mm2.**** connecting from top/bottom (read installation manual carefully to avoid wrong connection!)***** for additional remarks on product see technical part of the catalogue.****** highest clamp that can be placed on top side is P002 25-35, and on bottom side P002 50
3-pole horizontal fuse-switch disconnector HVL-P EK 000 (flat bar connection)Type Code No. Weight Packaging
[kg/pc] [pcs]
* HVL-P EK 000 are ready for mounting on mounting plate or mounting on 35mm mounting rail without accessories** HVL-P EK 00 are supplied with extra protective covering of connectors on the bottom side (PRS EK 000/3)*** connections are described in table of connections for HVL EK 000**** highest clamp that can be placed on top side is P002 25-35, and on bottom side P002 50
274
NV
/NH
PRS EK 000/1 001701450 0,02 2PRS EK 000/3 001701451 0,03 2PRS-B EK 000/3 001701452 0,03 2
HVL EK 00 3p M8 001701250 0,65 1HVL EK 00 3p OS00 6-50 001701251 0,63 1HVL EK 00 3p P00 10-70 001701252 0,69 1HVL EK 00 3p P00 35-95 001701255 0,72 1HVL EK 00 3p BT00 10-70 001701256 0,66 1
HVL EK 00 1p M8 001701410 0,28 3HVL EK 00 1p OS00 6-50 001701411 0,26 3HVL EK 00 1p P00 10-70 001701412 0,28 3HVL EK 00 1p P00 35-95 001701415 0,30 3HVL EK 00 1p BT00 10-70 001701416 0,28 3
579
* PRS EK 000… to be used for HVL EK 000, supplied in pairs covering the TOP and BOTTOM side** PRS-B EK 000 to be used for HVL-B EK 000, supplied in pairs covering the TOP and BOTTOM side
Accessories for HVL EK 000Type Code No. Description Weight Packaging
* HVL EK 00 are ready for mounting on mounting plate** basic Type of HVL EK 000 is screw connection M8 *** connections are described in table of connection s for HVL EK 00**** highest clamp that can be placed on top side is , while on bottom side there is no limitation (see table range of connections for HVL EK 000/00) ***** For clamp limitation, see table of accessories
* HVL EK 00 are ready for mounting on mounting plate** basic Type of HVL EK 000 is screw connection M8 *** connections are described in table of connections for HVL EK 00**** two-pole design can be made using two single-pole***** For clamp limitation, see table of accessories
* basic type of HVL EK 000 is screw connection M8 ** connector BT00 10-70 at dispossal only in combination with HVL-B EK for busbar (HVL-B EK 000 3p BT00 10-70) *** HVL EK 00 allows an easy change of mutual connections (except BT00 10-70)
Table of connections for HVL EK 000
275
NV
/NH
HVL EK 00 4p M8 001701430 0,92 1HVL EK 00 4p BT00 10-70 001701431 0,92 1
HVL-P EK 00 3p M8 001701260 0,67 1HVL-P EK 00 3p OS00 6-50 001701261 0,65 1HVL-P EK 00 3p P00 10-70 001701262 0,71 1
* HVL EK 00 are ready for mounting on mounting plate** basic Type of HVL EK 000 is screw connection M8 *** connections are described in table of connection s for HVL EK 00*** switching off neutral pole (N) same time as switching phase polarity***** For clamp limitation, see table of accessories
3-pole horizontal fuse-switch disconnector HVL-P EK 00 (additional flat bar connection)Type Code No. Weight Packaging
[kg/pc] [pcs]
* HVL-P EK 00 are ready for mounting on mounting plate** HVL-P EK 00 are supplied without any extra protective covering of connectors*** connections are described in table of connection s for HVL EK 00 ***** For clamp limitation, see table of accessories
Example:
NVdisconnectorswithfuses
technicaldataonpage
276
NV
/NH
DIN EK 00 125-150 001701453 3
OS00 6-16 001701460
Cu**
HVL EK 000 3OS00 25-50 001701461 HVL EK 000 3OS00 6-50 001701480 HVL EK 00 3
P00 10-35 001701462
Cu/Al**
HVL EK 000 3P00 50-70 001701463 HVL EK 000 3P00 10-70 001701481 HVL EK 00 3P00 35-95* 001701464 HVL EK 00 3P002 10-16 001701465
Cu/Al**
HVL EK 000 3P002 25-35 001701466 HVL EK 000 3P002 10-35 001701482 HVL EK 00*** 3P002 50 001701467 HVL EK 000, 00 *** 3P002 35-70* 001701468 HVL EK 00*** 3
579,582
* DIN EK 00 125-150 set allows to mount HVL EK 00 on two mounting rails in distance of 125mm or 150mm.
* connections P00 35-95 and BT00 10-70 should be orderd with fuse-switch disconnector while latter exchange is not possible ** basic type of HVL EK 00 is screw connection M8*** HVL EK 00 allows an easy change of mutual connections (except BT00 10-70 and P00 35-95)
Table of connections for HVL EK 00
Accessories for HVL EK 000/00 (connectors)Type Code No. Connector drawing Suitability Packaging
[pcs]
* because of wider screw distance change is only possible between these two Types of connections (however always possible to change connections OS with P00 and P002 and vice versa only the exceptions are marked with '*')** Type of cable for direct connection is given on connector drawing*** Double prism clamp (P002) can be used only on bottom side of HVL EK 00, while on top side clamps (OS00 and P00) remain
NVdisconnectorswithfuses
Accesories for HVL EK 00Type Code No. Description Packaging
[pcs]DIN EK 00 125-150 001701453 Mounting brackets for mounting