Top Banner
March 17, 2003 Nirmalya Parua The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003 Overview Of the D0 Calorimeter Shifter’s task
32

Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003 Overview Of the D0 Calorimeter.

Jan 29, 2016

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

The RunII Calorimeter

Nirmalya Parua(For the Calorimeter Group)

Shifter’s Tutorial March 17, 2003

Overview Of the D0 Calorimeter

Shifter’s task

Page 2: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Overview of Detector

Page 3: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Calorimeter OverviewZ

X

Y

Page 4: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Overview of the Calorimeter

Liquid argon sampling Stable, uniform response, rad. hard, fine spatial seg. LAr purity important

Uranium absorber (Cu or Steel for coarse hadronic) Compensating e/ 1, dense compact

Uniform, hermetic with full coverage < 4.2 ( 2o), int total)

Energy Resolution e: E / E = 15% /E+ 0.3% : E / E = 45% /E + 4% (RunI numbers, RunII is somewhat

worse now, and we don’t have the final result)

For more details

# The D0 Detector ("The NIM paper")

Nucl. Instr. and Methods, A338, 185 (1994)

FERMILAB-PUB-93/179-E PS

Page 5: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Overview of the Calorimeter

L. Ar in gap 2.3 mm

Ur absorber

Cu pad readout on 0.5 mm G10 with resistive coat epoxy

Drift time 430 ns

Page 6: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Overview of the Calorimeter

Page 7: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Intercryostat Detector (ICD)

Design Scintillator based with phototube readout . 16 supertile modules per cryostat with a total of 384 scintillator tiles WLS fiber readout of scintillator tiles Clear fiber light piping to region of low field ~40-50% signal loss over 5-6m fiber. Readout/calibration scheme for electronics similar as for L. Ar. Calorimeter .

ICD

FPS

Page 8: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

2”

FET

driverpreamp

Readout

Bank 1

Preamp/Driver

Trig. sum

Filter/Shaper

x1

x8

SCA (48 deep)

SCA (48 deep)

SCA (48 deep)

SCA (48 deep)

Bank 0

Calorimeter

Calibration

55k readout channels

SCA(48 deep)

A n. Bu

f

f

A

D

C

481

peak

base

Cable replaced for impedance matching

Page 9: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Preamplifier

FET

2”

driverpreamp

New calorimeter preamp

Hybrid on ceramic 48 preamps on a

motherboard New low-noise

switching power supplies in steel box

•Dual FET Frontend

•Compensation for Det. Cap.

•Faster Recovery Time

New output Driver for terminated

signal

1152 boards

55296 hybrids

Page 10: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Base Line Subtracter (BLS)

ADC’s have 12 bit dynamic range. To achieve 15 bit dynamic range SCAs have low and high gain path for each readout channels (X8/X1)

SCAs are not designed for simultaneous read/write operations. Two banks of SCAs, upper and lower (can’t see in the picture), for alternate read/write operation.

Readout time ~6 µs (length of SCA buffers 132 X 46 >6 µs).

Trigger tower formation 0.2 X 0.2 for Level 1.

Trigger summers/Drivers1152 BLS boards

4608 SCA cards 23440 SCAs

Trig Summers

Page 11: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Shifter’s Tutorial, 2003Nirmalya Parua

More on SCA’s

… .…

… .…

x8

x1

L1 SCA up

L2 SCAADC

down

Mean value

AD

C c

ou

nts

L1 SCA up

L1 SCA down

L2 SCA

Page 12: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

T&C cards

Timing and control Card

Trigger

system

BLS ADC

Pulser

Calorimeter

Preamplifier

Receives trigger, accelerator, clock information

Samples BLS shapers at the signal peak and base.

Keeps track of the memory location of crossings.

Generates busy signal when system is not ready.Coordinates pulser calibration.

12 T&C boards and 1 controller board is used

Page 13: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

www-d0online.fnal.gov -> Group Managed web pages -> Cal

Page 14: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

Page 15: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

Page 16: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

General:

Locate the monitors and orient yourself.

Open/login to the electronic logbook

Recognize/start all calorimeter monitoring GUIs

Fill out the checklist in a timely manner.

Make sure archiver is running

Check the status of the FPDs.

Page 17: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

When There is beam and we are in Global runningMake sure that all low voltage and high voltage supplies are on and working.

Reset any tripped supplies.

Set to data taking mode and download pedestals- cal_prepare_for_run.

Make sure that the pulsers are off.

Make sure all modes are set correctly.

Run the examine and L1cal_examine, identify hot cells and hot trigger towers.

Kill hot cells in the precision if needed, if there are hot trigger towers notify L1cal expert.

Paste examine plots in the logbook.

If any supplies trip, record trip parameters and reset the trip.

At the end of every runs stop the examines, at the beginning of runs start those.

Monitor the FPD running.

At the end of run record the run information in the database and logbook.

Place the FPD to standby before the end of the store.

Page 18: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s taskDuring quiet timeRemove the cal crates from Global run and take pedestal calibration run

Verify power supplies are off and working.

Verify pulsers are off.

Set the T&C system to fixed cell mode.

Check the calibration manager is running

Start the taker, select the trigger file, and take the runs.

Make sure the modes are set correctly

Enter the run parameters both in the logbook and in the database

Edit the trigger file and make the download file

Check the output, if satisfactory convert into the correct format and download.

Run a zero bias run and identify hotcells, kill if necessaryWhen there is no beamRun Cal examine and L1cal_ examine to find any problem.

Take any special runs that were requested.

Page 19: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

>start_cal alarm

Page 20: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task>start_cal

global>start_cal ioc

>start_cal rmi

Page 21: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task>start_cal supply

Page 22: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

Rightclick

Page 23: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

Page 24: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

Page 25: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

Page 26: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

Everything should be 0 during data taking.

Page 27: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

Page 28: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

>start_cal tandc

Page 29: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

>start_cal pulser

Page 30: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

>start_cal hv

Page 31: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

Shifter’s task

Cal_examine’s output, Any hotcells are written automatically after 1000 events

Page 32: Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.

March 17, 2003 Nirmalya Parua

New video shifter’s guide is being made that should orient the shifter and give them better

feelings about the detector.

Preview can be seen at

http://vmsstreamer1.fnal.gov/VMS_Site_02/Training/DzeroShifter/DzeroShifter2.htm