NEMA Type Terminal Blocks
Class 9080 – Type G
k
Orders must specify standard package quantity or multiples of that quantity.
f
These maximum current values assume the use of insulated copper conductors with 75°C temperature rating, and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of that wire or combination of wires (as listed in the above table) which has the greatest current carrying capacity. The actual allowable current for a particular application is dependent upon the number, size, insulation class and other characteristics of the wires used. The lower of the UL and CSA ratings are shown.
j
One end barrier required for each assembly of like blocks.
q
Terminals are tin plated, making them suitable for use with either copper or aluminum wire.
Description MaximumVoltage
MaximumCurrent
f
Blo cks End Barrie rs
j
Blo cks per Ft.
Max. Wire Combinations
Color Type PriceEach
Std.Pack
k
Type PriceEach
Std.Pack
k
Copper Wire(stranded or solid)
Solderless Box Lugfor #22 to #8 AWG wire.
Will mount on standard 9080 GH track or 35mm DIN 3 track.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
22-3
CP5 DiscountSchedule
3/00
22
TE
RM
INA
L B
LO
CK
S
k
Orders must specify standard package quantity or multiples of that quantity.
f
These maximum current values assume the use of insulated copper conductors with 75
o
C temperature rating, and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of that wire or combination of wires (as listed in the above table) which has the greatest current carrying capacity. The actual allowable current for a particular application is dependent upon the number, size, insulation class and other characteristics of the wires used. The lower of the UL and CSA ratings are shown below.
j
One end barrier required for each assembly of like sections.
q
Not intended to make or break a live circuit. Power must be disconnected from the circuit before operation of the switch.
t
Fuse Puller is supplied as standard with Class 9080 Type GF6 fuse block. The 9080GH63 is a replacement fuse puller.
u
Modules have RC circuitry for suppressing transient voltage, generated when opening a coil circuit, to approximately 200% of the peak line voltage, when used with 120 volt coils. Type GT6 is suitable for use with Square D Class 8501 Type X, K, R and C relays or Square D Type S starters and contactors, Sizes 00-2.
Description Maximum Voltage
Maximum Current
f
Blo cks End Barrie rs
j
Blo cksPer Ft.
Max. Wire Combinations
Type PriceEach
Std. Pack
k
Type PriceEach
Std. Pack
k
Copper Wire(stranded or solid)
Self-Lifting Pressure Wire Connector for #18 to #12 AWG wire. Will mount on standard 9080 GH track or 35mm
DIN 3 track. 600V 40A GP6
$ 1.60
50 GP6B
$ .66
10 32
1 or 2 #121 or 2 #141 or 2 #161 or 2 #18
Flat Terminal Connector for #22 to #12 AWG wire. Screws are #6-32 x
5
⁄
16
inch for Ring or Spade Lugs,
5
⁄
16
inch wide maximum.Will mount on standard 9080 GH
track or 35mm DIN 3 track.FINGERSAFE® per DIN 57470
600V 40A GA6
1.20
50 GP6B
.66
10 321 or 2 ConductorsPer Screw#12 - 22
Circuit Isolating Switch
q
with Self-Lifting PressureConnectors
for #18 to #10 AWG wire.Will mount on standard 9080 GH
track or 35mm DIN 3 track.600V 30A GG6
7.80
10 GF6B
.97
10 16
1 #101 #121 #141-4 #161-4 #18
Slip-on Connectors for #22 to #12 AWG wire. Tabs accept .250 x .032"
Slip-on ConnectorsWill mount on standard 9080 GH
track or 35mm DIN 3 track.600V 20A GS6
1.60
10 GF6B
.97
10 16
1-2 #121-2 #141-2 #161-2 #181-2 #201-2 #22
Transient Voltage Suppressors
u
with Box Lug Connectorsfor #18 to #10 AWG wire.
Will mount on standard 9080 GH track or 35mm DIN 3 track.
120V – GT6
13.30
5 GT6B
1.10
10 24
1 #101 #121 #141-2 #161-4 #18
Fuse Block for
13
⁄
32
" Dia. x 1
1
⁄
2
"ferrule fuse with Self-LiftingPressure Connectors. Fuse
Puller is included as standard.Fuses are not included.
Will mount on standard 9080 GH track or 35mm DIN 3 track.
FINGERSAFE® per DIN 57470
600V 30A GF6
7.50
10 GF6B
.97
10 16
1 #101 #121 #141-4 #161-4 #18
Fuse Puller
t
– – GH63
1.50
10 N/A N/A N/A
Blown Fuse Indicator/Pullers are neon pilot
lights which plug on to thefuse in a standard Type
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
22-4
CP5 DiscountSchedule
3/00
22
TE
RM
INA
L B
LO
CK
S
Standa rd Terminal Blo ck Assemblies
The assemblies listed in the table below consist of 6 feet (two 3 footlengths packaged together) of terminal blocks. The terminal blocks aremounted on snap-off mounting track, which can be easily broken every5/16th of an inch. Every tenth terminal block is marked to aid in countingoff the proper number of terminal blocks. After adding the proper endbarrier and a slip-in end clamp to the blocks that were broken off, thecustom assembly is ready for installation.
Description Type Price
Assembly of 188 Type GA6 GA6188BC
$341.
Assembly of 204 Type GR6 GR6204BC
434.
Assembly of 166 Type GC6 GC6166BC
669.
Assembly of 94 Type GF6 GF694BC
844.
Assembly of 296 Type GM6 GM6296BC
534.
Assembly of 188 Type GP6 GP6188BC
420.
Custo m Terminal Blo ck Assemblies
Order an assembly built as required for the application. As standard,custom assemblies use 9080GH mounting track with screw on endclamps. Other options are available from the table below.
One terminal blo ck type:
The number of blocks in the assembly isadded to the end of the catalog number of the desired block. Example:an assembly of
25
9080GR6 blocks would be
9080GR625
.
q
The 9080GH10 screw-on end clamp is
not
recommended for use with snap off channel. It is recommended that the 9080GH11 slip-in end clamp be used. Therefore, when the suffix
B
is used, it should be followed by the suffix
C
.
More than one terminal blo ck type in an assemb ly:
A detaileddrawing or sketch of the desired assembly must accompany the order.
Option Suffix Example
Substitute Slip-in end clamps
C
9080GR625C
Substitute Snap-off channel
B
9080GR625BC
q
For direct mount assembly of 9080 GK6 blocks
D
9080GK67D
Add a blank vinyl marking strip
M
9080GR625M
Add pre-marked (1-25 only) marking strip
MPO
9080GR625MPO
Mount on 35mm DIN3 track instead of 9080GH track
T
9080GR625T
Custom Assemb ly Pricing
Price per block from the table above . . . . . . . . . . . . . . . . __________Number of blocks in the assembly . . . . . . . . . . . . . . . . . .
x
________Subtotal (multiply # of blocks by price of blocks) . . . . . . . __________
Initial Charge for factory assemblies All except 9080GK6 direct mount
($4.50)
. . . . . . . OR for 9080GK6 direct mount
($2.30)
. . . . . . . . . . __________
Vinyl Marking Strips Adder for Suffix
M
- $0.03 per block . . . . . . . . . . . . OR adder for Suffix
MPO
- $0.15 per block . . . . . . __________Deduct for Suffix
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
22-6 CP5 DiscountSchedule 3/00
22T
ER
MIN
AL
BL
OC
KS
IEC Type Terminal BlocksAB1RR Spring Clip Blocks
k Orders must specify standard package quantity (Std. Pack) or multiples of that quantity.f These maximum current values assume the use of insulated copper conductors with 75°C temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is
the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application is dependent upon the size, insulation class and other characteristics of the wire used. The UL rating are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings.
a One end barrier is required for each assembly of like blocks.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
22-7CP5 DiscountSchedule3/00
22T
ER
MIN
AL
BL
OC
KS
k Orders must specify standard package quantity (Std. Pack) or multiples of that quantity.f These maximum current values assume the use of insulated copper conductors with 75°C temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is
the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application is dependent upon the size, insulation class and other characteristics of the wire used. The UL rating are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings.
a One end barrier is required for each assembly of like blocks.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
22-8 CP5 DiscountSchedule 3/00
22T
ER
MIN
AL
BL
OC
KS
k Orders must specify standard package quantity (Std. Pack) or multiples of that quantity.f These maximum current values assume the use of insulated copper conductors with 75°C temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is
the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application is dependent upon the size, insulation class and other characteristics of the wire used. The UL rating are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings.
a One end barrier is required for each assembly of like blocks.
Description Maximum Voltage
Maximum Current
f
Blo ck End Barrier a
Color Catalog Number
Price Each
Std. Packk Color Catalog
NumberPrice Each
Std. Packk
6mm (0.24") wide
Grounding Block
Solid or StrandedCopper Wire22-12 AWG
600 V 20A Green/Yellow AB1TP435U $4.00 100 Not required for this block.
8mm (0.31") wide
Grounding Block
Solid or Stranded Copper Wire22-8 AWG
600 V 30A Green/Yellow AB1TP635U 4.40 100 Not required for this block.
10mm (0.39") wide
Grounding Block
Solid or StrandedCopper Wire16-6 AWG
600 V 65A Green/Yellow AB1TP1035U 5.00 50 Not required for this block.
12mm (0.47") wide
Grounding Block
Solid or StrandedCopper Wire12-4 AWG
600 V 85A Green/Yellow AB1TP1635U 6.00 50 Not required for this block.
16mm (0.63") wide
Grounding Block
Solid or StrandedCopper Wire10-2 AWG
600 V 95A Green/Yellow AB1TP3535U 8.50 20 Not required for this block.
Description
Blo ck End Barrier a
Color Catalog Number Price Each
Std. Pack
kColor Catalog
NumberPrice Each
Std. Pack
k
6mm (0.24") wide
Two Tier Blocks
Solid or Stranded Copper Wire 22-10 AWG
600V 20A f
Standard two tier block Grey AB1ET435U $2.60 100
Grey AB1TE 0.70 50
Standard two tier block + upper-lower link Black AB1ET435U2 4.00 100
Standard two tier block+ grounding
Green/Yellow
AB1ET435UTP 12.00 100
Standard two tier block + red 24V LED Red AB1ET435UBRO 11.00 100
Standard two tier block + green 24V LED Red AB1ET435UBVE 11.00 100
Standard two tier block + head to tail diodes (red) Orange AB1ET435UBGE 11.00 100
Standard two tier block + diode upper-lower Red AB1ET435UHBRO 7.00 100
Standard two tier block+ diode lower-upper Orange AB1ET435UBHGE 7.00 100
Standard two tier block + 2 diodes Red AB1VV435U2DRO 12.40 100
IEC Type Terminal BlocksAB1TP Grounding and AB1ET Two Tier Blocks
For additional information, reference the IEC Type Terminal Block Catalog #9080CT9901 pages 14 through 16 or D-FAXTM #4344.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
22-9CP5 DiscountSchedule3/00
22T
ER
MIN
AL
BL
OC
KS
k Orders must specify standard package quantity (Std. Pack) or multiples of that quantity.f These maximum current values assume the use of insulated copper conductors with 75°C temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is
the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application is dependent upon the size, insulation class and other characteristics of the wire used. The UL rating are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings.
a One end barrier is required for each assembly of like blocks.
Description Maximum Voltage
Maximum Current
f
Blo ck End Barrier a
Color Catalog Number Price Each
Std. Pack
kColor Catalog
NumberPrice Each
Std. Pack
k
6mm (0.24") wide
Three Tier BlockSolid or Stranded
Copper Wire22-12 AWG
300 V 25A
Grey
AB1DDP235U $3.50 100
Not required for these blocks.
Three Tier Blockw / 24V LED (+)
Solid or Stranded Copper Wire 22-12 AWG
AB1DDP235ULP 6.50 100
Three Tier Block w / 24V LED (-)
Solid or StrandedCopper Wire 22-12 AWG
AB1DDP235ULM 6.50 100
6mm (0.24") wide
Three Tier Block w / ground
Solid or Stranded Copper Wire 22-12 AWG
Grey with
Green/Yellow
AB1DDP235T 5.50 100
Three Tier Block w / 24V LED (+) and ground
Solid or Stranded Copper Wire 22-12 AWG
AB1DDP235TLP 8.50 100
Three Tier Block w / 24V LED (-) and ground
Solid or Stranded Copper Wire22-12 AWG
AB1DDP235TLM 8.50 100
6mm (0.24") wide
Three Tier Block Solid or Stranded
Copper Wire22-12 AWG
Grey AB1ET3235U 5.50 100
Three Tier Block w / 24V LED (+) and ground
Solid or Stranded Copper Wire 22-12 AWG
Grey with
Green/Yellow
AB1ET3235UTLP 17.90 100
Three Tier Block w / 24V LED (-) and ground
Solid or Stranded Copper Wire 22-12 AWG
AB1ET3235UTLM 17.90 100
Three Tier Block w /ground
Solid or Stranded Copper Wire 22-12 AWG
AB1ET3235UT 8.10 100
Description Maximum Voltage
Maximum Current
f
Blo ck End Barrier a
Color Catalog Number
Price Each
Std. Pack
kColor Catalog
NumberPrice Each
Std. Pack
k
6mm (0.24") wide
Two Tier Block (one terminal in and two out )
Solid or Stranded Copper Wire 22-10AWG
600 V 30A
Grey AB1ETN335U $2.30 100 Grey AB1TEN3 $0.70 10
Two Tier Block (two terminals in and two out )
Solid or Stranded Copper Wire 22-10 AWG
Grey AB1ETN435U 3.30 100 Grey AB1TEN4 0.80 10
Grounding Block (two terminals in and two out )
Solid or Stranded Copper Wire 22-10 AWG
Green/Yellow AB1ETNTP435U 7.80 100 Not required for this block.
IEC Type Terminal BlocksAB1DD Three Tier and AB1ETN Two Tier Blocks
File LR89150Class 6228 01
File E164359CNN XCFR2
For additional information, reference the IEC Type Terminal Block Catalog #9080CT9901 pages 17 through 19 or D-FAXTM #4344, 4357.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
22-10 CP5 DiscountSchedule 3/00
22T
ER
MIN
AL
BL
OC
KS
k Orders must specify standard package quantity (Std. Pack) or multiples of that quantity.f These maximum current values assume the use of insulated copper conductors with 75°C temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is
the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application is dependent upon the size, insulation class and other characteristics of the wire used. The UL rating are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings.
a One end barrier is required for each assembly of like blocks.
DescriptionBlo ck End Barrier a
Color Catalog Number Price Each
Std. Pack k Color Catalog
NumberPrice Each
Std. Pack k
8mm (0.31") wide
Fuse Block For 5x20 or 5x25 mm fuse
Solid or Stranded Copper Wire 22-10 AWG
Maximum Voltage - 600V Maximum Current - 15A f
Open up with no indicator Grey AB1FUSE435U5X $5.00 50
Not required for these blocks.With 5-12V LED indicator Grey AB1FUSE435U5XJ 10.30 50With 12-24V LED indicator Grey AB1FUSE435U5XB 10.30 50
With 110-250V neon indicator Grey AB1FUSE435U5XM 10.30 50
10mm (0.39") wide
Fuse Block For 1/4 x 1 1/4 inch fuse
Solid or Stranded Copper Wire 22-10 AWG
Maximum Voltage - 600V Maximum Current - 15A f
Open up with no indicator Grey AB1FUSE436U5X 9.30 50
Not required for these blocks.With 5-12V LED indicator Grey AB1FUSE436U5XJ 12.00 50With 12-24V LED indicator Grey AB1FUSE436U5XB 12.00 50
With 110-250V neon indicator Grey AB1FUSE436U5XM 12.00 50
12mm (0.47") wide
Fuse Block For 5 x 20 mm fuse
Solid or Stranded Copper Wire 22- 6 AWG
Maximum Voltage - 600V Maximum Current - 15A f
Open up with no indicator Grey AB1FU10135U 7.00 50
The AB1FU10135 , AB1FU10235U, and AB1FU10335U are not UL component recognized.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
22-11CP5 DiscountSchedule3/00
22T
ER
MIN
AL
BL
OC
KS
k Orders must specify standard package quantity (Std. Pack) or multiples of that quantity.f These maximum current values assume the use of insulated copper conductors with 75°C temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is
the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application is dependent upon the size, insulation class and other characteristics of the wire used. The UL rating are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings.
a One end barrier is required for each assembly of like blocks.
Description
Blo ck End Barrier a
Color Catalog Number Price Each
Std. Pack
kColor Catalog
NumberPrice Each
Std. Pack
k
12 mm (0.47") wide
Block for Diodes (Diodes not includes)
Solid or Stranded Copper Wire22-10 AWG
Grey AB1D11435U $8.00 50 Not required for this block.
6mm (0.24") wide
Circuit Isolation Block
Solid or Stranded Copper Wire 22-10 AWG
Maximum Voltage - 600V Maximum Current - 20Af
With no test sockets Grey AB1SC435U 4.50 50
Grey AB1PS4 $0.55 50
With two test sockets Grey AB1SC435U2PT 4.50 50
6mm (0.24") wide
Box Lug / Slip-on Block
Solid or Stranded Copper Wire 22-14 AWG
Maximum Voltage - 300V Maximum Current - 10Af
Box lug on one side. Slip-on access from top
and sideGrey AB1FV135U 1.90 100 Grey AB1TC01 0.90 50
Box lug on one side. Slip-on access from top Grey AB1FC335U 2.50 100 Grey AB1TC3 0.90 50
Slip-on connectors on both sides Grey AB1FF235U 2.50 100 Not required for this block.
Description
Blo ck Partition
Color Catalog Number
Price Each
Std. Pack
kColor Catalog
NumberPrice Each
Std. Pack
k
32mm (1.26") wide
Lug / Lug Block
Solid or Stranded Copper Wire 6-3/0 AWG
M10 bolt
Maximum Voltage - 600V Maximum Current - 200Af
Grey AB1BB9535 $13.70 10 Grey AB1CT1 $1.50 50
42mm (1.65") wide
Lug / Lug Block
Solid or Stranded Copper Wire
1/0 - 400 kcmil
M12 bolt
Maximum Voltage - 600VMaximum Current - 325Af
Grey AB1BB18535 17.60 10 Grey AB1CT2 1.70 50
42mm (1.65") wide
Lug / Lug Block
Solid or Stranded Copper Wire
1/0 - 500 kcmil
M12 bolt
Maximum Voltage - 600V Maximum Current - 375Af
Grey AB1BB24035 29.00 10 Grey AB1CT2 1.70 50
32mm (1.26") wide
Lug / Clamp Block
Solid or Stranded Copper Wire 6-3/0 AWG
M10 bolt
Maximum Voltage - 600V Maximum Current - 200Af
Grey AB1BC9535 13.70 10 Grey AB1CT1 1.50 50
42mm (1.65") wide
Lug / Clamp Block
Solid or Stranded Copper Wire
1/0 - 300 kcmil
M12 bolt
Maximum Voltage - 600V Maximum Current - 325Af
Grey AB1BC15035 17.60 10 Grey AB1CT2 1.70 50
42mm (1.65") wide
Lug / Clamp Block Solid or Stranded
Copper Wire 1/0 - 500 kcmil
M12 bolt
Maximum Voltage - 600V Maximum Current - 375Af
Grey AB1BC24035 29.00 10 Grey AB1CT2 1.70 50
IEC Type Terminal BlocksAB1 Other Blocks
File LR89150Class 6228 01
File E164359CNN XCFR2
For additional information, reference the IEC Type Terminal Block Catalog #9080CT9901 pages 20 and 24 through 27 or D-FAXTM #4357.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
22-12 CP5 DiscountSchedule 3/00
22T
ER
MIN
AL
BL
OC
KS
k Orders must specify standard package quantity (Std. Pack) or multiples of that quantity.f These maximum current values assume the use of insulated copper conductors with 75°C temperature rating and are calculated based on NEC Article 310, Table 310-16. In most cases this value is
the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application is dependent upon the size, insulation class and other characteristics of the wire used. The UL rating are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings.
a One end barrier is required for each assembly of like blocks.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
22-13CP5 DiscountSchedule3/00
22T
ER
MIN
AL
BL
OC
KS
Marking Catalog Number Price Each Std.
Pack k
Black capital letters on white background
A AB1GA
$0.50 25
B AB1GB
C AB1GC
D AB1GD
E AB1GE
F AB1GF
G AB1GG
H AB1GH
I AB1GI
J AB1GJ
K AB1GK
L AB1GL
M AB1GM
N AB1GN
O AB1GO
P AB1GP
Q AB1GQ
R AB1GR
S AB1GS
T AB1GT
U AB1GU
V AB1GV
W AB1GW
X AB1GX
Y AB1GY
Z AB1GZ
AB1SR6 0.50 200
AB1SA1 0.50 500
AB1SA2 0.50 500
AB1SA3 0.50 500
AB1RT 0.50 500
AR1SB2 1.20 100
AR1SB3 0.60 50
A A A A A A A A A A
AB1GA
IEC Type Terminal BlocksAB1 Markers
For additional information, reference the IEC Type Terminal Block Catalog #9080CT9901 pages 28 and 29 or D-FAXTM #4357.
k Orders must specify standard package quantity (Std. Pack) or multiples of that quantity.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
22-14 3/00
22T
ER
MIN
AL
BL
OC
KS
CP5 DiscountSchedule
IEC Type Terminal BlocksMounting Track and End Clamps
7.5 mm depth, 1 mm steel, zinc chromatedEN50022 & NF C63-015
2 m / 78.74" AM1DP200 10.60 10
DIN1
Asymmetrical 32 mm trackEN50035 & NF C63-018
15 mm steel, zinc chromated
2 m / 78.74"DZ5MB201 15.80 10
DIN2
Symmetrical 15 mm trackEN50045
1 m / 39.37" AB1PC15 4.80 10
Dimensions
End Clamps Catalog Number
PriceEach
Std. kPack
Plastic end clamp for 32 mm DIN 1 track, 7.5 mm (0.30") wide
AB1AB7P32 $ 1.60 100
Metal end clamp for 32 mm DIN 1 track, 7.5 mm (0.30") wide
AB1AB10M32 1.60 100
Pastic end clamp for 15 mm DIN 2 track, 7.5 mm (0.30") wide
AB1AB715 1.00 100
AM1DE200 AM1ED200
AM1DP200
DZ5MB201
.246
.6516.5
1.2632
.061.5
.5915
78.742000
1.5.06
1.38 35
78.742000
15.59
1.06 27
.287
25.98
12.51.
38 3578.742000 15
.59
1.06 27
.04125
.49
.9825.98
.287
25.98
12.5
1.38 35
78.742000 15
.59
1.06 27
1.04
25
.49
.9825.98
DZ5MB201
39.371000
.205
.041
.348.5
.5915
k Orders must specify standard package quantity (Std. Pack) or multiples of that quantity.
Description LengthClass 9080Type
PriceEach
Std.k
Pack
Symmetrical rail 35 x 7.5mm(1.38" x .295") in compliance withEN50022 standard (DIN 46277-3).
Galvanized steel,(no
mounting holes)
0.08 m / 3" MH203 $2.00
10
0.10 m / 4" MH204 2.300.13m / 5" MH205 2.600.15 m / 6" MH206 3.000.18 m / 7" MH207 3.300.20 m / 8" MH208 3.600.23 m / 9" MH209 4.000.25 m / 10" MH210 4.300.28 m / 11" MH211 4.600.30 m / 12" MH212 5.000.33 m / 13" MH213 5.300.36 m / 14" MH214 5.600.38 m / 15" MH215 6.000.41 m / 16" MH216 6.300.42 m / 17" MH217 6.600.46 m / 18" MH218 7.00
0.50 m / 19.68" MH220 7.401 m / 39.37" MH239 12.702 m / 78.74" MH279 19.00
Galvanized steel,
prepunched
0.08 m / 3" MH303 2.200.10 m / 4" MH304 2.500.13m / 5" MH305 3.000.15 m / 6" MH306 3.300.18 m / 7" MH307 3.700.20 m / 8" MH308 4.000.23 m / 9" MH309 4.400.25 m / 10" MH310 4.700.28 m / 11" MH311 5.200.30 m / 12" MH312 5.500.33 m / 13" MH313 5.900.36 m / 14" MH314 6.200.38 m / 15" MH315 6.600.41 m / 16" MH316 7.000.42 m / 17" MH317 7.400.46 m / 18" MH318 7.70
0.50 m / 19.68" MH320 8.401 m / 39.37" MH339 14.802 m / 78.74" MH379 21.10
High rise track Aluminum 1 m /39.37" MH439 18.00 2
Dimensions
Angle bracket kit Catalog Numbert
PriceEach
Std. kPack
For mounting 9080 GH or MH track to a panel at 45˚ angle. Includes 2 brackets and hardware for mounting the track to the brackets.
9080MH82 $4.60 1
End Clamps
Plastic end clamp for 35 mm DIN 3 track, 8 mm (0.31") wide
AB1AB8P35 1.00 100
Metal end clamp for 35 mm DIN 3 track, 8 mm (0.31") wide
AB1AB8M35 1.50 100
Polycarbonate end clamp for 35 mm DIN 3 track, 8 mm (0.31") wide
9080MHA10 1.50 50
.25 6
.7118
.9825
"A"
.307.5.04
1
.9825
1.3835
461.80
301.17
9080MHA109080MH3**
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com