  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    1/100

    ND-70924 (E)ISSUE 1

    STOCK # 151993

    Data Interface System Manual

    JULY, 2000

    NEC America, Inc.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    2/100

    LIABILITY DISCLAIMER

    NEC America, Inc. reserves the right to change the specifications,functions, or features, at any time, without notice.

    NEC America, Inc. has prepared this document for use by itsemployees and customers. The information contained herein is

    the property of NEC America, Inc. and shall not be reproducedwithout prior written approval from NEC America, Inc.

    NEAX and Dterm are registered trademarks of NEC Corporation.

    Copyright 2000

    NEC America, Inc.

    Printed in U.S.A.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    3/100

    ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4

    DATE JULY, 2000 DATE DATE DATE

    ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8

    DATE DATE DATE DATE

    NEAX2000 IVS2

    Data Interface System Manual Revision Sheet 1/2

    ND-70924 (E)

    PAGE No.ISSUE No.

    1 2 3 4 5 6 7 8

    i 1

    ii 1

    iii 1

    iv 1

    1 12 1

    3 1

    4 1

    5 1

    6 1

    7 1

    8 1

    9 1

    10 1

    11 1

    12 1

    13 1

    14 1

    15 1

    16 1

    17 1

    18 1

    19 1

    20 1

    21 1

    22 1

    23 1

    24 1

    25 1

    26 1

    27 1

    28 1

    29 1

    30 1

    31 1

    32 1

    33 1

    34 1

    35 1

    36 1

    37 1

    38 1

    39 140 1

    41 1

    42 1

    43 1

    44 1

    45 1

    46 1

    47 1

    48 1

    49 1

    50 1

    51 1

    52 1

    53 1

    54 1

    55 1

    56 1

    57 1

    58 1

    59 1

    60 1

    61 1

    62 1

    63 1

    64 1

    65 1

    66 1

    67 1

    68 1

    69 1

    70 1

    71 1

    72 1

    PAGE No.ISSUE No.

    1 2 3 4 5 6 7 8

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    4/100

    ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4

    DATE JULY, 2000 DATE DATE DATE

    ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8

    DATE DATE DATE DATE

    NEAX2000 IVS2

    Data Interface System Manual Revision Sheet 2/2

    ND-70924 (E)

    73 1

    74 1

    75 1

    76 1

    77 178 1

    79 1

    80 1

    81 1

    82 1

    83 1

    84 1

    85 1

    86 1

    87 1

    88 1

    89 1

    90 1

    91 1

    92 1

    93 1

    94 1

    PAGE No.ISSUE No.

    1 2 3 4 5 6 7 8PAGE No.

    ISSUE No.

    1 2 3 4 5 6 7 8

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    5/100

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page i

    NEAX2000 IVS2

    Data Interface System Manual

    TABLE OF CONTENTSPage

    LIST OF FIGURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii

    LIST OF TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv

    INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1PURPOSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

    OUTLINE OF THIS MANUAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

    REFERENCE MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

    CHAPTER 1 GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3SYSTEM OUTLINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

    DPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    DTI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7M03 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    PLO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

    CARD NAME AND FUNCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

    SYSTEM CAPACITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

    System Capacity for Data Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

    System Capacity for Digital Trunk Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

    SYSTEM SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    DPC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    Modem Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    SYSTEM CONDITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

    Time Slot Assignment Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Time Slot Allocation for DTI Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    CHAPTER 2 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    Static Electricity Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    REQUIRED EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    INSTALLATION PROCEDURE FOR DATA INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

    Installation Summary for Data Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

    Mounting DPC Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

    Mounting M03 Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

    Conditions on Connecting DTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Connecting X.21 DTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

    Connecting V.24/V.28 DTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

    Connecting RS-449 DTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    Connecting V.35 DTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

    Installation Procedure for Digital Trunk Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

    Installation Summary for Digital Trunk Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

    Mounting DTI Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    6/100

    NEAX2000 IVS2 Data Interface System ManualPage ii ND-70924 (E), Issue 1.0

    TABLE OF CONTENTS

    Page

    Mounting CONN Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

    DTI Cable Connection via MDF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

    DTI Cable Connection via CONN Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

    CHAPTER 3 SYSTEM DATA PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45HOW TO READ THIS CHAPTER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

    DATA INTERFACE ASSIGNMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

    DIGITAL TRUNK INTERFACE ASSIGNMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

    CHAPTER 4 OPERATION TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55DPC LOOPBACK TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

    DPC Loopback 1 Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

    DPC Loopback 2 Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

    OTHER LOOPBACK TESTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

    INTER-OFFICE DIGITAL DATA TRANSMISSION TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

    CHAPTER 5 CIRCUIT CARD INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63HOW TO READ THIS CHAPTER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

    MOUNTING LOCATION OF CIRCUIT CARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

    LIST OF REQUIRED CIRCUIT CARDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

    PN-CP14 (MP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

    PN-24DTA-C (DTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

    PN-30DTC-A (DTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

    PZ-M542 (CONN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

    PZ-M557 (CONN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86

    PN-2DPCB (DPC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88PN-M03 (M03) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    7/100

    LIST OF FIGURES

    Figure Title Page

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page iii

    Figure 1-1 System Outline of Intra-Office Data Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

    Figure 1-2 System Outline of Inter-Office Data Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

    Figure 1-3 Clock Supply Route . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

    Figure 1-4 Accommodation of DTI into TDSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

    Figure 1-5 Time Slot Allocation for DTI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Figure 2-1 Static Electricity Guard (1 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Figure 2-1 Static Electricity Guard (2 of 2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

    Figure 2-2 Installation Procedure for Data Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

    Figure 2-3 Limitation on Using Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

    Figure 2-4 Cable Connection between DPC Card and X.21 DTE/Modem . . . . . . . . . . . . . . . . . . 23

    Figure 2-5 Cable Connection between DPC Card and X.21 DTE/Modem . . . . . . . . . . . . . . . . . . 25

    Figure 2-6 DPC V11 Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

    Figure 2-7 Cable Connection between DPC Card and V.24/V.28 DTE/Modem . . . . . . . . . . . . . . 28

    Figure 2-8 Cable Connection between DPC Card and V.24/V.28 DTE/Modem . . . . . . . . . . . . . . 29

    Figure 2-9 DPC RS Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

    Figure 2-10 Cable Connection between DPC Card and RS-449 DTE . . . . . . . . . . . . . . . . . . . . . . 31Figure 2-11 RS-449 Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

    Figure 2-12 X.21 Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

    Figure 2-13 Outline of V.35 Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

    Figure 2-14 Cable Connection between M03 Card and V.35 DTE/Modem . . . . . . . . . . . . . . . . . . 34

    Figure 2-15 Cable Connection between M03 Card and V.35 DTE/Modem . . . . . . . . . . . . . . . . . . 35

    Figure 2-16 DPC V35 Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

    Figure 2-17 V.35 Connector Pin Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

    Figure 2-18 Installation Procedure for DTI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

    Figure 2-19 DTI Cable Connection via MDF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

    Figure 2-20 Location of the AP Slots and the LTC Connectors for DTI . . . . . . . . . . . . . . . . . . . . . 41

    Figure 2-21 Example of MDF Cross Connection for DTI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

    Figure 2-22 DTI Cable Connection via CONN Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

    Figure 2-23 Example of Coaxial Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

    Figure 4-1 DPC Loopback Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

    Figure 4-2 Connection of Modem Tester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

    Figure 4-3 Other Loopback Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

    Figure 4-4 Inter-Office Digital Data Transmission Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

    Figure 5-1 Mounting Location of Circuit Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    8/100

    NEAX2000 IVS2 Data Interface System ManualPage iv ND-70924 (E), Issue 1.0

    LIST OF TABLES

    Table Title Page

    Table 1-1 Connecting Patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

    Table 1-2 Card Name and Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

    Table 1-3 System Capacity for Data Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

    Table 1-4 System Capacity for Digital Trunk Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

    Table 1-5 DPC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Table 1-6 Rate Adaptation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    Table 1-7 Modem Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    Table 2-1 Required Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    Table 2-2 X.21 to RS-449 Adapter Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    Table 2-3 V.35 Interface Cable Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

    Table 5-1 List of Required Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    9/100

    INTRODUCTIONPurpose

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 1

    INTRODUCTION

    PURPOSE

    This manual explains the installation, programming and operation test procedure for the Data

    Interface system on the NEAX2000 IVS2.

    OUTLINE OF THIS MANUAL

    This manual contains the following chapters:

    CHAPTER 1 GENERAL INFORMATION

    This chapter explains the system outline, the name and functions of circuit cards required,system capacity, system specifications and system conditions of Data Interface system.

    CHAPTER 2 INSTALLATION

    This chapter explains the hardware installation procedure to provide Data Interface on the PBX.

    CHAPTER 3 SYSTEM DATA PROGRAMMING

    This chapter explains the programming procedure to provide the Data Interface on the PBX.

    CHAPTER 4 OPERATION TEST

    This chapter explains the operation tests to be performed after completing the installation of theData Interface on the PBX.

    CHAPTER 5 CIRCUIT CARD INFORMATION

    This chapter explains the mounting location, the meaning of lamp indications, and the method of

    switch settings of each circuit card for the Data Interface.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    10/100

    NEAX2000 IVS2 Data Interface System ManualPage 2 ND-70924 (E), Issue 1.0

    INTRODUCTIONReference Manual

    REFERENCE MANUAL

    During installation, refer also to the manuals below:

    Command Manual: Describes Customer Administration Terminal (CAT)

    operation, command function and setting data required for

    programming the system, and Resident System Program.

    Office Data Programming Manual: Contains the Customer Specification Sheet and Office Data

    Programming Sheet.

    Maintenance Manual: Describes the maintenance service features and the

    recommended troubleshooting procedure.

    Installation Procedure Manual: Explains the installation procedure for the PBX system.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    11/100

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 3

    CHAPTER 1

    GENERAL INFORMATION

    This chapter explains the Data Interface system outline, the name and

    functions of circuit cards required, system capacity, specifications,

    and conditions.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    12/100

    NEAX2000 IVS2 Data Interface System ManualPage 4 ND-70924 (E), Issue 1.0

    CHAPTER 1 GENERAL INFORMATIONSystem Outline

    SYSTEM OUTLINE

    The Data Interface can provide the intra- or inter-office digital data transmission on fixed path

    (Nailed-Down) connection. The Data Interface equips the V.11 (X.21) and the V.24/V.28

    (RS-232C) interface. When you use the V.11 (X.21) interface, a maximum of 64 kbps digital data

    transmission is available. When you use the V.24/V.28 (RS-232C) interface, a maximum of 19.2

    kbps digital data transmission is available.

    To add the V.11 (X.21) or V.24/V.28 (RS-232C) Data Interface to the system, it is necessary to

    install the Data Port Controller (DPC) card. You can provide the V.35 interface DTE by the M03

    card installed in addition to the DPC card. The M03 card converts the V.11 (X.21) interface to a

    V.35 interface. When you provide the inter-office digital data transmission, it is necessary to

    install the 24/30-channel Digital Trunk Interface (DTI) card in addition to the DPC card.

    Figure 1-1 and Figure 1-2 show the outline of the Data Interface intra-office/inter-officeconnection.

    Figure 1-1 System Outline of Intra-Office Data Connection

    NOTE: The DPC card can only operate as DCE. If the DPC card is to be connected to a modem

    or other DCE, a null modem adapter is required.

    SYNCHRONOUS

    DATA AT SPEEDSOF 56 kbps, 64 kbps

    PBX

    DTE

    DTE

    DPC

    DPC

    NAILED-DOWN CONNECTION(DATA STATION TO DATA STATION)

    DPC: DATA PORT CONTROLLER

    DTE: DATA TERMINAL EQUIPMENT

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    13/100

    CHAPTER 1 GENERAL INFORMATIONSystem Outline

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 5

    When the PBX is an end office in the Inter-Office Digital Data Transmission through Nailed-Down

    Connection, the digital signal is transmitted directly. A maximum of 64 kbps digital data

    transmission is available for the direct digital transmission.

    When the PBX is a tandem office in the Inter-Office Digital Data Transmission through Nailed-

    Down Connection, data transparency is provided, and a maximum of 64 kbps digital data

    transmission is available.

    Table 1-1 shows the connecting pattern of the Inter-Office Data Transmission through Nailed-

    Down Connection.

    : Direct Connection: Tandem Connection

    : Not available

    Table 1-1 Connecting Patterns

    CONNECTING PATTERNSYSTEM

    CONFIGURATIONTOFROM

    LDT/ODT DTI(DIGITAL SIGNAL)

    DPC Figure 1-2

    LDT/ODT

    DTI

    (Digital Signal)

    Figure 1-2

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    14/100

    NEAX2000 IVS2 Data Interface System ManualPage 6 ND-70924 (E), Issue 1.0

    CHAPTER 1 GENERAL INFORMATIONSystem Outline

    Figure 1-2 System Outline of Inter-Office Data Connection

    DTI

    PBX

    (2) PBX IS A NTANDEM OFFICE:

    DTI

    PBX

    DTE

    DPC

    DPC

    DPC: DATA PORT CONTROLLER

    DTE : DATA TERMINAL EQUIPMENT

    DTI : 24/30 CHANNEL DIGITAL TRUNK INTERFACE

    M : MODEM

    PLO : PHASE LOCKED OSCILLATOR

    DTE

    DPC

    MMTODTE

    DTI

    MP PLO

    NAILED-DOWN CONNECTION

    24/30 CHANNEL PCMDIGITAL LINE

    DIGITALPBX

    CLOCK SIGNAL

    TDSW

    (1) PBX IS AN END OFFICE:

    NAILED-DOWN CONNECTION

    MP PLO

    CLOCK SIGNALTDSW

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    15/100

    CHAPTER 1 GENERAL INFORMATIONSystem Outline

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 7

    DPC

    The Data Port Controller (DPC) can accommodate a maximum of two DTE per cards with V.11

    (X.21) or V.24/V.28 (RS-232C) interface, and can provide the intra-office or inter-office digital

    data transmission on Nailed-Down connection.

    DTI

    The Digital Trunk Interface (DTI) interfaces the PBX directly to a 24/30-channel PCM

    transmission line. The DTI has the following functions.

    For 24DTI:

    Unipolar/Bipolar Conversion (AMI Format)

    Signaling Insertion/Extraction

    Alarm Detection/Insertion

    Digital PAD on Voice Signal Transmission

    Loopback Test (Local/Remote Loopback)

    Cyclic Redundancy Checking (based on ITU-T Rec. G704)

    For 30DTI:

    Unipolar/Bipolar Conversion (HDB3 Format)

    Signaling Insertion/Extraction

    Alarm Detection/Insertion

    Digital PAD on Voice Signal Transmission

    Cyclic Redundancy Checking (based on ITU-T Rec. G704)

    Channel Associated Signaling (based on ITU-T Rec. 0421 Digital R2 Signaling Code)

    For connection of a 24DTI and transmission line, twisted-pair cables can be used. For connection

    of a 30DTI and transmission line, either coaxial cable or twisted pair cable can be used.

    M03

    The M03 provides V.35 Data Terminal Equipment interface.

    M03 is connected to the DPC and converts V.11 (X.21) interface to V.35 interface.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    16/100

    NEAX2000 IVS2 Data Interface System ManualPage 8 ND-70924 (E), Issue 1.0

    CHAPTER 1 GENERAL INFORMATIONSystem Outline

    PLO

    The Phase Locked Oscillator (PLO) equipped on the MP card synchronizes the system to the

    digital network clock.

    When the PBX is a clock receiver office, the PLO generates the clock signals according to the

    source clocks received from the source office within the network. The source clock signals are

    extracted at DTI cards and supplied to the PLO. Two clock routes are available; one is the Route

    0 from the source office, and the other is a standby Route 1 from a sub-source office. When no

    clock signals arrive from the source and sub-source office, due to a transmission line failure, the

    PLO keeps generating the clock signals at the frequency of the previous source clock. The PLO

    can receive different frequency of source clocks from the Route 0 and Route 1.

    Figure 1-3 shows an example of the clock supply route when the system is a receiver office.

    Figure 1-3 Clock Supply Route

    NOTE: DTI 0 and DTI 1 must be mounted in PIM0.

    PLO

    TDSW

    SOURCE OFFICE

    ~

    SOURCECLOCK

    RECEIVER/LOCAL-RECEIVER OFFICE

    DTI

    DTI

    TDSW

    RECEIVER OFFICE

    DTI

    DTI

    DTI

    TDSW

    SUB-SOURCE OFFICE

    PLO

    DTI

    DTI 1

    DTI 0DTI

    DTI

    PLO

    PLO: DIRECTION OF CLOCK

    SIGNAL SUPPLY

    TDSW

    PBX NOTE

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    17/100

    CHAPTER 1 GENERAL INFORMATIONCard Name and Function

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 9

    CARD NAME AND FUNCTION

    Table 1-2 shows the circuit card name and function for Data Interface.

    Table 1-2 Card Name and Function

    EQUIPMENT

    NAME

    FUNCTIONAL

    NAMEFUNCTION

    PN-CP14 MP Main Processor Card

    Provides Memory, TDSW (1024CH 1024CH), 16-line

    CFT, PB sender, Clock, PLO 2 ports (receiver mode/

    source mode), two RS-232C ports, 2-line DAT (Recording

    duration: Max. 128 sec.), DK, 4-line PB receiver, Modem

    for remote maintenance (19.2 kbps), internal Music-on-

    Hold tone source and BUS interface. BUS interfacefunctions as a driver/receiver of various signals, adjusts

    gate delay timing and cable delay timing, monitors I/O Bus

    and PCM BUS.

    One card is required per system.

    PN-24DTA-C DTI Digital Trunk Interface (23B + D, 1.5 Mbps) Card

    Accommodates 24-channel PCM digital lines.

    PN-30DTC-A DTI Digital Trunk Interface (2 Mbps) Card

    Accommodates 30-channel PCM digital lines.

    PZ-M542

    [For Other

    Countries]

    CONN Coaxial Cable Connection Card

    Used to connect a coaxial cable for the Digital Trunk

    Interface.

    Two cards maximum can be connected to LTC connector

    of each PIM.

    PZ-M557

    [For

    Australia]

    CONN Coaxial Cable Connection Card

    Used to connect a coaxial cable for the Digital Trunk

    Interface.

    Two cards maximum can be connected to LTC connectorof each PIM.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    18/100

    NEAX2000 IVS2 Data Interface System ManualPage 10 ND-70924 (E), Issue 1.0

    CHAPTER 1 GENERAL INFORMATIONCard Name and Function

    PN-2DPCB DPC 2-line Data Port Controller Card

    Used for the intra-office or inter-office digital data

    transmission on nailed down connection.

    Accommodates max. two DTEs with V.11 (X.21) interface

    or V.24/V.28 (RS-232C) interface.

    PN-M03 M03 V.35 Data Terminal Equipment Interface Card

    Used together with the PN-2DPCB card to provide the

    V.35 interface.

    Table 1-2 Card Name and Function (Continued)

    EQUIPMENT

    NAME

    FUNCTIONAL

    NAMEFUNCTION

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    19/100

    CHAPTER 1 GENERAL INFORMATIONSystem Capacity

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 11

    SYSTEM CAPACITY

    System Capacity for Data Interface

    System Capacity for Digital Trunk Interface

    Table 1-3 System Capacity for Data Interface

    DESCRIPTION CAPACITY REMARKS

    DPC Card 50

    Circuits per DPC Card 2

    Fixed Path Connection 100

    Table 1-4 System Capacity for Digital Trunk Interface

    DESCRIPTIONCAPACITY

    REMARKS24DTI 30DTI

    DTI Card 8 4

    DTI Trunk 192 124

    DTI Trunk Route 64 64 1 Route/DTI

    Ports per DTI Card 24 31

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    20/100

    NEAX2000 IVS2 Data Interface System ManualPage 12 ND-70924 (E), Issue 1.0

    CHAPTER 1 GENERAL INFORMATIONSystem Specifications

    SYSTEM SPECIFICATIONS

    DPC Specifications

    NOTE 1: When the transmission rate is 56 or 64 kbps, only full duplex is available.

    NOTE 2: For the transmission rate after Rate Adaptation, see Table 1-6.

    Modem Specifications

    NOTE: When the transmission rate is 56 or 64 kbps, only full duplex is available.

    Table 1-5 DPC Specifications

    DESCRIPTION SPECIFICATION

    Synchronization Synchronous

    Transmission Rate 2.4, 4.8, 9.6, 14.4, 19.2, 48, 56, 64 kbps

    Transmission Mode Full/Half Duplex NOTE 1

    Rate Adaptation NOTE 2 ITU-T V.110

    Table 1-6 Rate Adaptation

    TRANSMISSION RATE

    BEFORE RATE ADAPTATION

    TRANSMISSION RATE

    AFTER RATE ADAPTATIONREMARKS

    2.4-4.8 kbps 8 kbps

    9.6 kbps 16 kbps

    14.4 kbps 32 kbps

    19.2 kbps 32 kbps

    48-64 kbps 64 kbps

    Table 1-7 Modem Specifications

    DESCRIPTION SPECIFICATION

    Synchronization Synchronous

    Transmission Rate 2.4, 4.8, 9.6, 14.4, 19.2, 48, 56, 64 kbps

    Transmission Mode Full/Half Duplex NOTE

    Line 4 wire

    Connecting Type Leased

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    21/100

    CHAPTER 1 GENERAL INFORMATIONSystem Conditions

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 13

    SYSTEM CONDITIONS

    Time Slot Assignment Condition

    As shown in Figure 1-4, the 30DTI card uses the time slot on the basic Highway 4.

    Therefore, the total number of time slots for all 30DTI card must be 128 time slots or lessincluding all other application processor cards which use the Highway 4.

    The 24DTI card can use the time slot on both the basic and expanded Highway 4 and 6.

    Therefore, the total number of time slots for all 24DTI card must be 256 time slots or less.

    Figure 1-4 Accommodation of DTI into TDSW

    PRT

    TDSW(1024T

    IMESLOTS)

    FP0

    FP1

    FP2

    FP3

    DTI

    DCH

    FOR L/T CARDS: MAX. 512 TIME SLOTS PER SYSTEM

    FOR BASIC HIGHWAY4: MAX. 128 TIME SLOTS PER SYSTEM

    1 TIME SLOT/CARD

    MAX. 128 TIME SLOTS

    MAX. 128 TIME SLOTS

    MAX. 128 TIME SLOTS

    MAX. 128 TIME SLOTS

    30DTI: MAX. 31 TIME SLOTS/CARD

    BRT

    ICH

    DTI

    MAX. 2 TIME SLOTS/CARD (BRTA)

    MAX. 4 TIME SLOTS/CARD (2BRTC)

    25 TIME SLOT/CARD

    24DTI: MAX. 24 TIME SLOTS/CARD

    1 TIME SLOT/CARD (SC02)

    4 TIME SLOTS/CARD (SC03)

    FOR EXPANDED HIGHWAY6: MAX. 128 TIME SLOTS PER SYSTEM

    HW4

    HW6

    FOR AP CARDS: MAX. 256 TIME SLOTS PER SYSTEM

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    22/100

    NEAX2000 IVS2 Data Interface System ManualPage 14 ND-70924 (E), Issue 1.0

    CHAPTER 1 GENERAL INFORMATIONSystem Conditions

    Time Slot Allocation for DTI Card

    On each DTI card, the system recognizes the lowest and highest channel numbers to which trunk

    numbers have been assigned, and allocates time slots to all the channels within them. If trunk

    numbers are assigned to discontinuous channels in this case, the system also allocates time

    slots to channels not assigned.

    For example, as shown in Figure 1-5, even when Channel 1 through Channel 10 have been

    assigned by the system data programming (CM07 YY=01) except Channel 5, the system

    allocates a total of 10 time slots for all the ten channels. Therefore, to avoid allocation of

    unnecessary time slots, it is recommended that consecutive channels are assigned on each DTI

    card.

    Figure 1-5 Time Slot Allocation for DTI

    10

    9

    6

    5

    4

    1

    CH0

    DXXX

    DXXX

    DXXX

    NONE

    DXXX

    DXXX

    NONE

    LOWEST CHANNEL

    HIGHEST CHANNEL

    10 TIME SLOTS AREALLOCATED EVENWHEN CH5 IS NOT

    ASSIGNED.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    23/100

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 15

    CHAPTER 2

    INSTALLATION

    This chapter explains the hardware installation procedure to provide

    Data Interface to the PBX.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    24/100

    NEAX2000 IVS2 Data Interface System ManualPage 16 ND-70924 (E), Issue 1.0

    CHAPTER 2 INSTALLATIONPrecautions

    PRECAUTIONS

    Static Electricity Guard

    You must wear a grounded wrist strap to protect circuit cards from static electricity.

    Figure 2-1 Static Electricity Guard (1 of 2)

    WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD

    WHEN HOLDING A CIRCUIT CARD

    PBX

    WRIST STRAP

    FRAME GROUND SCREW

    CARD FRONT

    NEVER TOUCH THE COMPONENTS OR

    SOLDERED SURFACE WITH BARE HANDS.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    25/100

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    26/100

    NEAX2000 IVS2 Data Interface System ManualPage 18 ND-70924 (E), Issue 1.0

    CHAPTER 2 INSTALLATIONPrecautions

    CautionYou must hold the edge of a circuit card when plugging or unplugging the circuit card. If you

    touch another area, you may be exposed to hazardous voltages.

    CARD FRONT

    NEVER TOUCH THE COMPONENTS OR

    SOLDERED SURFACE WITH BARE

    HANDS.

    PBX

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    27/100

    CHAPTER 2 INSTALLATIONRequired Equipment

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 19

    REQUIRED EQUIPMENT

    Table 2-1 shows the equipment required to provide the Data Interface on the system.

    Table 2-1 Required Equipment

    EQUIPMENT/CABLE DESCRIPTION QTY REMARKS

    PN-2DPCB Data Port Controller Card 1-50

    PN-24DTA-C 24 channel DTI Card 1-8 For Inter-office

    PN-30DTC-A 30 channel DTI Card 1-4 For Inter-office

    PN-M03 V.35 DTE Interface Card 1-50

    PZ-M542/M557 Coaxial Cable Connection

    Card

    1-4 2 cards/PIM

    1 card/DTI

    DPC V11 CABLE Connection Cable between

    PN-2DPCB and V.11

    (X.21) DTE

    N N: Number of V.11

    (X.21) DTE

    4 m (13.1 ft.)

    17-TW-0.3 CONN

    CABLE-A

    Connection Cable between

    PN-2DPCB and PN-M03

    N N: Number of V.35 DTE

    0.3 m (1 ft.)

    DPC V35 CABLE Connection Cable between

    PN-M03 and V.35 DTE

    N N: Number of V.35 DTE

    4 m (13.1 ft.)

    DPC RS CABLE Connection Cable betweenPN-2DPCB and V.24/V.28

    DTE

    N N: Number of V.24/V.28DTE

    4 m (13.1 ft.)

    MODEM Refer to Modem

    Specifications. Page 12

    2 N N: Number of DTE

    (As required)

    (Should be provided by

    customer.)

    Straight Cable Connection Cable between

    DPC V11 CABLE/DPC RS

    CABLE and DTE

    N N: Number of DTE

    (When connecting DTE

    directly)(Should be provided by

    customer.)

    Reverse Cable Connection Cable between

    DPC V11 CABLE/DPC RS

    CABLE and Modem

    N N: Number of DTE

    (When using modem)

    (Should be provided by

    customer.)

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    28/100

    NEAX2000 IVS2 Data Interface System ManualPage 20 ND-70924 (E), Issue 1.0

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    INSTALLATION PROCEDURE FOR DATA INTERFACE

    Installation Summary for Data Interface

    Install the equipment according to the procedure shown in Figure 2-2.

    Figure 2-2 Installation Procedure for Data Interface

    START

    Mounting DPC Card

    END

    Page 21

    Mounting M03 CardConnecting X.21 DTE Connecting RS-449

    Whichtype of DTE?

    DTEConnecting V.24/V.28

    DTE

    Connecting V.35 DTE

    Page 21Page 31Page 28Page 23

    Page 33

    X.21 V.24/V.28 RS-449 V.35

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    29/100

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 21

    Mounting DPC Card

    (1) Confirm the correct switch settings of the DPC card.

    See CHAPTER 5. Page 63.

    (2) Mount the DPC cards in LT00 through LT11 slots of PIM0 through PIM7.

    Mounting M03 Card

    (1) Confirm the correct switch settings of the M03 card.

    See CHAPTER 5. Page 63.

    (2) Mount the M03 cards in LT00 through LT11 slots of PIM0 through PIM7.

    ATTENTIONContentsStatic SensitiveHandling

    Precautions Required

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    30/100

    NEAX2000 IVS2 Data Interface System ManualPage 22 ND-70924 (E), Issue 1.0

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    Conditions on Connecting DTE

    Forcible ON control of DTR, RTS/C signal:

    When connecting the DTE which does not support the DTR signal and RTS/C signal, these

    signals can be turned to ON forcibly by switch setting on the DPC card.

    Condition of CTS signal ON control:

    The CTS signal is turned to ON after 60 ms from the time when receiving the RTS/C signal. And

    the CTS signal is turned to ON under the following conditions.

    1. The DTR signal is ON.

    2. The received X signal is ON (The synchronization of the opposite office is established).

    3. The sending X signal is ON (The synchronization of the PBX is established).

    Limitation on using modem:When using modem, the DTR signal from the DTE can not be transmitted to the PBX (DPC card).

    Therefore, the DTE starting by the DTR signal can not be used.

    Figure 2-3 Limitation on Using Modem

    TXD

    RXD

    DTR

    RTSCTS

    DCD

    DSR

    TXC(2)

    RXC

    TXD

    RXD

    DTR

    RTSCTS

    DCD

    DSR

    TXC(2)

    RXC

    TXC(1)

    TXD

    RXD

    DTR

    RTSCTS

    DCD

    DSR

    TXC(2)

    RXC

    TXC(1)

    TXD

    RXD

    DTR

    RTSCTS

    DCD

    DSR

    TXC(2)

    RXC

    TXD

    RXD

    DTR

    RTSCTS

    DCD

    DSR (ON)

    TXC(2)

    RXC

    TXC(1)

    S-BB TXD

    RXD

    DTR

    RTSCTS

    DCD

    DSR

    TXC(2)

    RXC

    TXC(1)

    ~

    X DTR

    DTE PBX PBX MODEM MODEM DTE

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    31/100

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 23

    Connecting X.21 DTE

    Connect the X.21 DTE/modem to the DPC card as shown in Figure 2-4.

    Figure 2-4 Cable Connection between DPC Card and X.21 DTE/Modem

    (Continued)

    2A

    2B

    3A

    3B

    4A

    4B

    5A

    5B

    6A

    4D

    3C

    6D

    6B

    2

    9

    3

    10

    4

    11

    5

    12

    6

    8

    13

    2

    9

    3

    10

    4

    11

    5

    12

    6

    14

    7

    8

    13

    T

    C

    R

    I

    S

    TXC(1)

    GND

    T

    C

    R

    I

    S

    GND

    T

    C

    R

    I

    S

    TXC(1)

    GND

    XCN0/XCN1 CONNECTOR

    STRAIGHT CABLE (LOCALLY PROVIDED)

    DPC

    X.21DTE

    (J) (J) (P) (P)

    4 m (13.1 ft.)

    14

    7TXC(1)

    DPC V11 CABLE

    Page 27

    (1) Direct Connection

    NOTE 1

    L NOTE 2

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    32/100

    NEAX2000 IVS2 Data Interface System ManualPage 24 ND-70924 (E), Issue 1.0

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    NOTE 1: When providing X.21 DTE with TXC(1) signal, this connection is required.

    NOTE 2: The distance between the DPC card and X.21 DTE is as follows.

    When providing X.21 DTE with TXC(1) signal: L=Max. 1000 m (3281 ft.)When providing X.21 DTE without TXC(1) signal, the distance depends on the data

    speed.

    (Continued)

    Distance (L) Data SpeedMax. 1000 m (3281 ft.) . . . . . . .

    Max. 800 m (2625 ft.) . . . . . . . .

    Max. 350 m (1148 ft.) . . . . . . . .

    Max. 300 m (984 ft.) . . . . . . . . .

    Max. 250 m (820 ft.) . . . . . . . . .

    Less than 9.6 kbps

    19.2 kbps

    48 kbps

    56 kbps

    64 kbps

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    33/100

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 25

    Figure 2-5 Cable Connection between DPC Card and X.21 DTE/Modem

    (Continued)

    XCN0/XCN1 CONNECTOR

    REVERSE CABLE (LOCALLY PROVIDED)

    DPC

    X.21MODEM

    (J) (J) (P) (P)

    4 m (13.1 ft.)

    2A

    2B

    3A

    3B

    4A

    4B

    5A

    5B

    6A

    4D

    3C

    6D

    6B

    2

    9

    3

    10

    4

    11

    5

    12

    6

    8

    13

    2

    9

    3

    10

    4

    11

    5

    12

    6

    14

    7

    8

    13

    T

    C

    R

    I

    S

    TXC(1)

    GND

    T

    C

    R

    I

    S

    GND

    T

    C

    R

    I

    S

    TXC(1)

    GND

    When using a modem that has not TXC(1) terminal

    When using a modem that can provide TXC(1) signal

    14

    7TXC(1)

    DPC V11 CABLE

    Page 27

    (2) Modem Connection

    2A

    2B

    3A

    3B

    4A4B

    5A

    5B

    6A

    4D

    3C

    6D

    6B

    2

    9

    3

    10

    411

    5

    12

    6

    14

    7

    8

    13

    T

    C

    R

    I

    S

    TXC(1)

    GND

    T

    C

    R

    I

    S

    GND

    T

    C

    R

    I

    S

    TXC(1)

    GND

    TXC(1)

    2

    9

    3

    10

    411

    5

    12

    6

    14

    7

    8

    13

    TXD

    RTS

    RXD

    DCD

    TXC(2)

    NOTE 1

    L NOTE 2

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    34/100

    NEAX2000 IVS2 Data Interface System ManualPage 26 ND-70924 (E), Issue 1.0

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    NOTE 1: When providing X.21 modem with TXC(1) signal, this connection is required.

    NOTE 2: The distance between the DPC card and X.21 modem is as follows.

    When providing X.21 modem with TXC(1) signal: L=Max. 1000 m (3281 ft.)When providing X.21 modem without TXC(1) signal, the distance depends on the data

    speed.

    Distance (L) Data SpeedMax. 1000 m (3281 ft.) . . . . . . .

    Max. 800 m (2625 ft.) . . . . . . . .

    Max. 350 m (1148 ft.) . . . . . . . .

    Max. 300 m (984 ft.) . . . . . . . . .

    Max. 250 m (820 ft.) . . . . . . . . .

    Less than 9.6 kbps

    19.2 kbps

    48 kbps

    56 kbps

    64 kbps

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    35/100

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 27

    Figure 2-6 DPC V11 Cable

    .............

    ............

    D A (J)

    (J)

    1

    6

    1 9

    158

    6D-GND

    2A-TA

    2B-TB

    4A-RA

    4B-RB

    6A-SA

    6B-SB

    3C-TXC(1)A

    4D-TXC(1)B

    3A-CA

    3B-CB

    5A-IA

    5B-IB

    IA-G

    8-GND

    2-TA

    9-TB

    4-RA

    11-RB

    6-SA

    13-SB

    7-TXC(1)A

    14-TXC(1)B

    3-CA

    10-CB

    5-IA

    12-IB

    6

    5

    4

    3

    2

    1

    SA

    IA

    RA

    CA

    TA

    G

    A

    SB

    IB

    RB

    CB

    TB

    B

    X

    TXC(1)

    X

    C

    GND

    TXC(1)

    X

    D

    7

    6

    5

    4

    3

    2

    8

    1

    TXC(1)A

    SA

    IA

    RA

    CA

    TA

    GND

    X

    14

    13

    12

    11

    10

    9

    15

    TXC(1)B

    SB

    IB

    RB

    CB

    TB

    X

    X: NOT CONNECTEDG: GROUND

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    36/100

    NEAX2000 IVS2 Data Interface System ManualPage 28 ND-70924 (E), Issue 1.0

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    Connecting V.24/V.28 DTE

    Connect the V.24/V.28 DTE/modem to the DPC card as shown in Figure 2-7.

    Figure 2-7 Cable Connection between DPC Card and V.24/V.28 DTE/Modem

    (Continued)

    05B

    05A

    04B

    04A

    03B

    03A

    02B

    02A

    06A

    04D

    05C

    06B

    GND

    RXD

    CTS

    GND

    TXC(2)

    DTR

    RS0/RS1 CONNECTOR

    STRAIGHT CABLE (LOCALLY PROVIDED)

    DPC

    V.24/V.28DTE

    (J) (J) (P) (P)

    4 m (13.1 ft.)

    MAX 15 m (49.2 ft.)

    DPC RS CABLE

    Page 30

    TXD

    RTS

    DSR

    DCD

    RXC

    TXC(1)

    1

    2

    3

    4

    5

    6

    7

    8

    15

    24

    20

    17

    GND

    RXD

    CTS

    GND

    TXC(2)

    DTR

    TXD

    RTS

    DSR

    DCD

    RXC

    TXC(1)

    1

    2

    3

    4

    5

    6

    7

    8

    15

    24

    20

    17

    GND

    RXD

    CTS

    GND

    TXC(2)

    DTR

    TXD

    RTS

    DSR

    DCD

    RXC

    TXC(1)

    (1) Direct Connection

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    37/100

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 29

    Figure 2-8 Cable Connection between DPC Card and V.24/V.28 DTE/Modem

    RS0/RS1 CONNECTOR

    REVERSE CABLE (LOCALLY PROVIDED)

    DPC

    V.24/V.28MODEM

    (J) (J) (P) (P)

    4 m (13.1 ft.)

    MAX 15 m (49.2 ft.)

    DPC RS CABLE

    page 30

    05B

    05A

    04B

    04A

    03B

    03A

    02B

    02A

    06A

    04D

    05C

    06B

    GND

    RXD

    CTS

    GND

    TXC(2)

    DTR

    TXD

    RTS

    DSR

    DCD

    RXC

    TXC(1)

    1

    2

    3

    4

    5

    6

    7

    8

    15

    24

    20

    17

    GND

    RXD

    CTS

    GND

    TXC(2)

    DTR

    TXD

    RTS

    DSR

    DCD

    RXC

    TXC(1)

    1

    2

    3

    4

    5

    6

    7

    8

    15

    24

    20

    17

    GND

    RXD

    CTS

    GND

    TXC(2)

    DTR

    TXD

    RTS

    DSR

    DCD

    RXC

    TXC(1)

    (2) Modem Connection

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    38/100

    NEAX2000 IVS2 Data Interface System ManualPage 30 ND-70924 (E), Issue 1.0

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    Figure 2-9 DPC RS Cable

    .............

    ............

    D A

    (J)

    1

    6

    1 14

    2513

    05B-GND

    02B-GND

    05A-TXD

    04B-RXD

    04A-RTS

    03B-CTS

    03A-DSR

    02A-DCD

    05C-DTR

    04D-TXC(1)

    06A-TXC(2)

    06B-RXC

    01C-RI

    01A-GND

    1-GND

    7-GND

    2-TXD

    3-RXD

    4-RTS

    5-CTS

    6-DSR

    8-DCD

    20-DTR

    24-TXC(1)

    15-TXC(2)

    17-RXC

    22-RI

    06

    05

    04

    03

    02

    01

    TXC(2)

    TXD

    RTS

    DSR

    DCD

    G

    A

    RXC

    GND

    RXD

    CTS

    GND

    B

    DTR

    X

    RI

    C

    X

    TXC(1)

    X

    D

    12

    11

    10

    9

    8

    7

    13

    6

    X

    X

    X

    X

    DCD

    GND

    X

    DSR

    24

    23

    22

    21

    20

    19

    25TXC(1)

    X

    RI

    X

    DTR

    X

    X

    X: NOT CONNECTEDG: GROUND

    5

    4

    3

    2

    1

    CTS

    RTS

    RXD

    TXD

    GND

    17

    16

    15

    14

    RXC

    X

    TXC(2)

    X

    18 X

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    39/100

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 31

    Connecting RS-449 DTE

    RS-449 DTE requires a locally provided conversion cable, as shown in Figure 2-10. This cable

    must be equipped with a 15-pin male D-type connector and a 37-pin D-type connector (male or

    female as required by DTE.) A modification is required to be installed in the 37-pin connector, as

    shown in the Table 2-2, Figure 2-11 and Figure 2-12.

    Figure 2-10 Cable Connection between DPC Card and RS-449 DTE

    Table 2-2 X.21 to RS-449 Adapter Cable Connections

    DPC (DCE)

    X.21, 15-pin Male D-type

    DTE

    RS-449, 37-pin D-type

    Name Function Pin Pin Name Source

    TA Transmit data A 2 4 TXD + DTE

    TB Transmit data B 9 22 TXD DTE

    RA Receive data A 4 6 RXD + DCE

    RB Receive data B 11 24 RXD DCE

    SA Clock A 6 5

    8

    SCT +

    SCR +

    DCE

    DCE

    SB Clock B 13 23

    26

    SCT

    SCR

    DCE

    DCE

    CA Control A 3 7 RTS + DTE

    CB Control B 10 25 RTS DTE

    IA Indicate A 13

    5 11

    9

    DCD +

    DSR +

    CTS +

    DCE

    DCE

    DCEIB Indicate B 31

    12 29

    27

    DCD

    DSR

    CTS

    DCE

    DCE

    DCE

    SG Signal ground

    (zero volts)

    19

    8 20

    37

    Signal ground

    RCV common

    SND common

    Common

    Common

    Common

    XCN0/XCN1 CONNECTOR X.21 to RS-449 ADAPTER CABLE

    DPC

    RS-449DTE

    (J) (J) (P) (J/P)

    DPC V11 CABLE

    Page 27

    (LOCALLY PROVIDED)

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    40/100

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    41/100

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 33

    Connecting V.35 DTE

    (1) Connect the M03 card and the DPC card as shown in Figure 2-13.

    (2) Connect the V.35 DTE/modem to the M03 card in the following pages.

    Figure 2-13 Outline of V.35 Cable Connection

    DPC

    V.35DTE/

    17-TW-0.3 CONN CABLE

    DPC V35 CABLEM03

    PBX

    V.35 INTERFACE CABLE

    MODEM

    XCN0/XCN1 CONNECTOR

    X21 CONNECTOR

    V35 CONNECTOR

    (LOCALLY PROVICED)

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    42/100

    NEAX2000 IVS2 Data Interface System ManualPage 34 ND-70924 (E), Issue 1.0

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    Figure 2-14 Cable Connection between M03 Card and V.35 DTE/Modem

    NOTE: When you provide V.35 DTE using TXC(1) signal, this connection is required.

    (Continued)

    V35 CONNECTOR

    STRAIGHT CABLE (LOCALLY PROVIDED)

    M03

    V.35DTE

    (J) (J) (P) (P)

    4 m (13.1 ft.)

    MAX 15 m (49.2 ft.)

    TXD 4A

    4B

    RXD 2A

    2B

    RTS 6A

    CTS 6B

    DSR 5A

    GND 6D

    DCD 5B

    TXC(2) 3A

    3B

    RXC 1C

    2D

    DTR 5C

    TXC(1) 3C

    4D

    TXD P

    S

    RXD R

    T

    RTS C

    CTS D

    DSR E

    GND B

    GND A

    DCD F

    TXC(2) Y

    AA

    RXC V

    X

    DTR H

    TXC(1) U

    W

    TXD P

    S

    RXD R

    T

    RTS C

    CTS D

    DSR E

    GND B

    GND A

    DCD F

    TXC(2) Y

    AA

    RXC V

    X

    DTR H

    TXC(1) U

    WNOTE

    DPC V35 CABLEPage 36

    (1) Direct Connection

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    43/100

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 35

    Figure 2-15 Cable Connection between M03 Card and V.35 DTE/Modem

    V35 CONNECTOR

    REVERSE CABLE (LOCALLY PROVIDED)

    M03

    V.35MODEM

    (J) (J) (P) (P)

    4 m (13.1 ft.)

    MAX 15 m (49.2 ft.)

    TXD 4A

    4B

    RXD 2A

    2B

    RTS 6A

    CTS 6B

    DSR 5A

    GND 6D

    DCD 5B

    TXC(2) 3A

    3B

    RXC 1C

    2D

    DTR 5C

    TXC(1) 3C

    4D

    TXD P

    S

    RXD R

    T

    RTS C

    CTS D

    DSR E

    GND B

    GND A

    DCD F

    TXC(2) Y

    AA

    RXC V

    X

    DTR H

    TXC(1) U

    W

    TXD P

    S

    RXD R

    T

    RTS C

    CTS D

    DSR E

    GND B

    GND A

    DCD F

    TXC(2) Y

    AA

    RXC V

    X

    DTR H

    TXC(1) U

    W

    (2) Modem Connection

    DPC V35 CABLEPage 36

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    44/100

    NEAX2000 IVS2 Data Interface System ManualPage 36 ND-70924 (E), Issue 1.0

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    Figure 2-16 DPC V35 Cable

    D A (J)

    (J)

    1

    6

    B

    NN

    6D-GND

    2A-RXDA

    2B-RXDB

    4A-TXDA

    4B-TXDB

    6A-RTS

    6B-CTS

    3C-TXC(1)A

    4D-TXC(1)B

    3A-TXC(2)A

    3B-TXC(2)B

    5A-DSR

    5B-DCD

    1C-RXCA

    6

    5

    4

    3

    2

    1

    RTS

    DSR

    TXDA

    TXC(2)A

    RXDA

    G

    A

    CTS

    DCD

    TXDB

    TXC(2)B

    RXDB

    B

    DTR

    TXC(1)A

    RXCA

    C

    GND

    TXC(1)B

    RXCB

    D

    X: NOT CONNECTEDG: GROUND

    2D-RXCB

    5C-DTR

    1A-GND

    B-GND

    R-RXDA

    T-RXDB

    P-TXDA

    S-TXDB

    C-RTS

    D-CTS

    U-TXC(1)A

    W-TXC(1)B

    Y-TXC(2)A

    AA-TXC(2)B

    E-DSR

    F-DCD

    Y-RXCA

    X-RXCB

    H-DTR

    A-GND

    B GND

    F DCD

    L X

    R RXDA

    V RXCA

    Z X

    DD X

    JJ X

    NN X

    D CTS

    J X

    N X

    T RXDB

    X RXCB

    BB X

    FF X

    LL X

    A GND

    E DSR

    K X

    P TXDA

    U TXC(1)A

    Y TXC(2)A

    CC X

    HH X

    MM X

    C RTS

    H DTR

    M X

    S TXDB

    W TXC(1)B

    AA TXC(2)B

    EE X

    KK X

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    45/100

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 37

    Figure 2-17 V.35 Connector Pin Assignment

    Table 2-3 V.35 Interface Cable Connector Pin Assignments

    Pin Name Function Specification Source

    A

    B

    C

    D

    E

    F

    H

    GND

    GND

    RTS

    CTS

    DSR

    RLSD

    DTR

    Frame Ground

    Signal Ground

    Request To Send

    Clear To Send

    Data Set Ready

    Received Line Signal Detector

    Data Terminal Ready

    RS-232

    RS-232

    RS-232

    RS-232

    RS-232

    DTE

    DCE

    DCE

    DCE

    DTE

    P

    S

    TXD Send Data V.35 DTE

    RT

    RXD Receive Data V.35 DCE

    U

    W

    SCTE Serial Clock Transmit External (A)

    Serial Clock Transmit External (B)

    V.35 DTE

    V

    X

    SCR Serial Clock Receive (A)

    Serial Clock Receive (B)

    V.35 DCE

    Y

    AA (or aa)

    SCT Serial Clock Transmit (A)

    Serial Clock Transmit (B)

    V.35 DCE

    L, M, N, Z, BB, CC, DD, EE,HH, JJ, KK, LL, MM, NN Reserved for future V.35 use

    B

    F

    R

    V

    D

    T

    X

    Signal Pin

    Chassis Ground A

    Request To Send C

    Data Set Ready E

    Data Terminal Ready HTransmitted Data P

    Transmitted Data S

    Transmit Timing U

    Transmit Timing W

    Transmit Timing Y

    Transmit Timing AA

    Pin Signal

    B Signal Ground

    D Clear To Send

    F Receive Line SignalDetect

    R Received Data

    T Received Data

    V Receive Timing

    X Receive Timing

    A

    E

    P

    U

    Y

    C

    H

    S

    W

    AA

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    46/100

    NEAX2000 IVS2 Data Interface System ManualPage 38 ND-70924 (E), Issue 1.0

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    INSTALLATION PROCEDURE FOR DIGITAL TRUNK

    INTERFACE

    Installation Summary for Digital Trunk Interface

    Install the equipment according to the procedure shown in Figure 2-18.

    Figure 2-18 Installation Procedure for DTI

    NOTE: This procedure is required when you provide CONN card to connect a coaxial cable for

    30DTI.

    START

    Selection of PLO inMP Card

    Mounting DTI Card

    DTI Cable Connection

    Page 39

    CHAPTER 5 Page 63

    Page 40via MDF

    Mounting CONN Card Page 39

    NOTE

    END

    DTI Cable Connection Page 43

    NOTEvia CONN Card

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    47/100

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 39

    Mounting DTI Card

    (1) Before mounting the DTI (PN-24DTA-C/PN-30DTC-A) card, set the MB

    switch to UP position, and set the other switches to appropriate position.

    See CHAPTER 5. Page 63

    (2) Mount the DTI card in the following AP slots on PIM0-PIM7.

    PIM0: AP00-AP10 slots

    PIM1-7: AP00-AP11 slots

    After mounting the card, set the MB to DOWN position to put the card in service.

    NOTE: The DTI card (DTI 0, DTI 1) which sends a clock signal to PLO of the MP card must be

    mounted in the AP slots on PIM0.

    Mounting CONN Card

    When you provide CONN (PZ-M542/M557) card to connect a coaxial cable for 30DTI, do the

    following installation.

    (1) Confirm the correct switch settings of the CONN card.

    See CHAPTER 5. Page 63

    (2) Mount the CONN card on LTC connector on BWB in the PIM which accomodates the DTIcards.

    For details, refer to the Installation Procedure Manual.

    ATTENTIONContentsStatic SensitiveHandling

    Precautions Required

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    48/100

    NEAX2000 IVS2 Data Interface System ManualPage 40 ND-70924 (E), Issue 1.0

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    DTI Cable Connection via MDF

    When you use a twisted-pair cable, connect the cable to a CSU via the MDF as shown below.

    Location of AP Slots and LTC Connectors for DTI - Page 41

    Example of MDF Cross Connection for DTI - Page 42

    Figure 2-19 DTI Cable Connection via MDF

    CSUMDF

    LTC0/LTC1/LTC2/LTC3 CONNECTOR

    TWISTED-PAIRCABLE

    BWB

    PBX(PIM0-PIM7)

    MAX. 200 m (655 ft.)

    Figure 2-20, Figure 2-21,Figure 2-22, Figure 2-23

    (SHIELD TYPE)

    DTI

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    49/100

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 41

    Figure 2-20 Location of the AP Slots and the LTC Connectors for DTI

    LTC0

    01

    02

    03

    04

    05

    06

    07

    08

    09

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    RA

    TA

    RA

    TA

    RA

    TA

    MJ

    RB

    TB

    RB

    TB

    RB

    TB

    MN

    RA

    TA

    RA

    TA

    RA

    TA

    RB

    TB

    RB

    TB

    RB

    TB

    RA

    TA

    RA

    TA

    RA

    TA

    RB

    TB

    RB

    TB

    RB

    TB

    RA

    TA

    RA

    TA

    RA

    TA

    RB

    TB

    RB

    TB

    RB

    TB

    26

    27

    28

    29

    30

    31

    32

    33

    34

    35

    36

    37

    38

    39

    40

    41

    42

    43

    44

    45

    46

    47

    48

    49

    50

    AP00SLOT

    AP01

    SLOT

    AP02

    SLOT

    LTC1

    01

    02

    03

    04

    05

    06

    07

    08

    09

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    26

    27

    28

    29

    30

    31

    32

    33

    34

    35

    36

    37

    38

    39

    40

    41

    42

    43

    44

    45

    46

    47

    48

    49

    50

    AP03

    SLOT

    AP04SLOT

    AP05

    SLOT

    LTC2

    01

    02

    03

    04

    05

    06

    07

    08

    09

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    26

    27

    28

    29

    30

    31

    32

    33

    34

    35

    36

    37

    38

    39

    40

    41

    42

    43

    44

    45

    46

    47

    48

    49

    50

    AP08

    SLOT

    AP07

    SLOT

    AP06SLOT

    AP11

    SLOT

    AP10

    SLOT

    AP09

    SLOT

    LTC3

    01

    02

    03

    04

    05

    06

    07

    08

    09

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    26

    27

    28

    29

    30

    31

    32

    33

    34

    35

    36

    37

    38

    39

    40

    41

    42

    43

    44

    45

    46

    47

    48

    49

    50

    L

    T

    1

    1

    /A

    P

    1

    1

    L

    T

    1

    0

    /A

    P

    1

    0

    L

    T

    0

    9

    /A

    P

    0

    9

    L

    T

    0

    8

    /A

    P

    0

    8

    L

    T

    0

    7

    /A

    P

    0

    7

    L

    T

    0

    6

    /A

    P

    0

    6

    L

    T

    0

    5

    /A

    P

    0

    5

    L

    T

    0

    4

    /A

    P

    0

    4

    L

    T

    0

    3

    /A

    P

    0

    3

    L

    T

    0

    2

    /A

    P

    0

    2

    L

    T

    0

    1

    /A

    P

    0

    1

    L

    T

    0

    0

    /A

    P

    0

    0

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    50/100

    NEAX2000 IVS2 Data Interface System ManualPage 42 ND-70924 (E), Issue 1.0

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    Figure 2-21 Example of MDF Cross Connection for DTI

    17

    18

    19

    20

    RA

    TA

    42

    43

    44

    45

    RB

    TB

    LTC1 (J)

    42

    43

    44

    45

    RB

    TB

    17

    18

    19

    20

    RA

    TA

    LTC1 (P)

    PIM 0

    J P MDFDTI

    AP05RA

    RB

    TA

    TB

    17

    42

    18

    43

    17

    42

    18

    43

    RA

    RB

    TA

    TB

    TO CSU

    LTC1

    RECEIVE

    TRANSMIT

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    51/100

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 43

    DTI Cable Connection via CONN Card

    When you use an coaxial cable, connect the cable to a CSU via the CONN (PZ-M542/M557) card

    as shown in Figure 2-22.

    Figure 2-23 shows an example of the cable connection when the 30DTI card is mounted in the

    AP05 slot of PIM0.

    Figure 2-22 DTI Cable Connection via CONN Card

    CSU

    LTC0/LTC1/LTC2/LTC3

    COAXIAL CABLE

    30DTI

    BWBPBX

    MAX. 6 dB loss at 1024 kHz

    CONN

    CONNECTOR

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    52/100

    NEAX2000 IVS2 Data Interface System ManualPage 44 ND-70924 (E), Issue 1.0

    CHAPTER 2 INSTALLATIONInstallation Procedure for Data Interface

    Figure 2-23 Example of Coaxial Cable Connection

    2 COAXIAL CONNECTOR

    1 LTC1 CONNECTOR

    LTC1 (J) LTC1 (P)

    PIM0

    J PCONN

    30DTI

    AP05RA

    RB

    TA

    TB

    17

    42

    18

    43

    17

    42

    18

    43

    TO CSU

    LTC1

    RECIEVE

    RCV

    TRANSMIT

    TRS

    17

    18

    19

    20

    RA

    TA

    42

    43

    44

    45

    RB

    TB

    17

    18

    19

    20

    RB

    TB

    42

    43

    44

    45

    RA

    TA

    21

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    53/100

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 45

    CHAPTER 3

    SYSTEM DATAPROGRAMMING

    This chapter explains the programming procedure to provide the Data

    Interface to the PBX.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    54/100

    NEAX2000 IVS2 Data Interface System ManualPage 46 ND-70924 (E), Issue 1.0

    CHAPTER 3 SYSTEM DATA PROGRAMMINGHow to Read This Chapter

    HOW TO READ THIS CHAPTER

    In the programming procedure, the meaning of (1), (2) and markings are as follows.

    (1) : 1st Data

    (2) : 2nd Data

    : Initial Data; With the system data clear command (CM00, CM01), the data with this

    marking is automatically set for each command.

    : A reset of the MP card is required after data setting.

    Press SW1 switch on the MP card.

    :A reset of the DTI card is required after data setting.

    Set the Make Busy switch to UP and then DOWN.

    INITIAL

    DTI INITIAL

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    55/100

    CHAPTER 3 SYSTEM DATA PROGRAMMINGData Interface Assignment

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 47

    DATA INTERFACE ASSIGNMENT

    DESCRIPTION DATA

    To assign data station number by CM1A,

    assign a station number (dummy number)to each port (LEN) on the DPC card.

    NOTE 1: The station number must beassigned to the first LEN (level

    0) and the third LEN (level 2) of

    each LT slot (The station

    number must be also assigned

    to the unused port on the DPC

    card).

    NOTE 2: The * and # can not be usedas a station number.

    (1)

    (2)

    000-763: LEN

    FX-FXXXXXXXX: Station No.X: 0-9

    Assign a data station number to the

    station number assigned by CM10.

    NOTE: The data station number must bealso assigned to the unused port

    on the DPC card.

    (1)

    (2)

    X-XXXXXXXX: Station No. assigned

    by CM10

    X-XXXXXXXX: Data Station No.

    Assign an access code for data station. (1)(2)

    Y=0-3 Numbering Plan Group 0-3

    X-XXXX: Access Code

    801: 1 digit station

    802: 2 digits station

    803: 3 digits station

    804: 4 digits station

    805: 5 digits station

    806: 6 digits station

    807: 7 digits station

    808: 8 digits station

    Assign the type of data terminal interface

    to the data station number.

    NOTE: This data must be also assignedto the unused port on the DPC

    card.

    (1)

    (2)

    X-XXXXXXXX: Data Station No.

    04: DPC

    CM1A

    CM20

    START

    CM10

    CMA0

    A

    INITIAL

    INITIAL

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    56/100

    NEAX2000 IVS2 Data Interface System ManualPage 48 ND-70924 (E), Issue 1.0

    CHAPTER 3 SYSTEM DATA PROGRAMMINGData Interface Assignment

    DESCRIPTION DATA

    Assign the attribute data for data station

    (assigned by CM1A) in accordance withthe specification of the DTE connected.

    (1)

    (2)

    YY=04 Data speed

    X-XXXXXXXX: Data Station No.00-05 : 1200 bps

    06 : 600 bps

    07 : 1200 bps

    08 : 2400 bps

    09 : 4800 bps

    10 : 9600 bps

    11 : 19.2 kbps

    12 : 48 kbps

    13 : 56 kbps

    14 : 64 kbps

    15 : 7200 bps16 : 14.4 kbps

    17-31 : 1200 bps

    (1)

    (2)

    YY=05 Parity CheckX-XXXXXXXX: Data Station No.0 : Effective

    1 : Ineffective

    (1)

    (2)

    YY=06 Synchronous/Asynchronous

    X-XXXXXXXX: Data Station No.

    0 : Synchronous

    7 : Asynchronous

    (1)

    (2)

    YY=07 Transmission Mode

    X-XXXXXXXX: Data Station No.

    0 : Half Duplex

    1 : Full Duplex

    A

    B

    CMA1

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    57/100

    CHAPTER 3 SYSTEM DATA PROGRAMMINGData Interface Assignment

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 49

    DESCRIPTION DATA

    (1)

    (2)

    YY=08 Stop Bit

    X-XXXXXXXX: Data Station No.

    0 : 2-Stop Bit

    1 : 1-Stop Bit

    (1)

    (2)

    YY=09 Type of Code

    X-XXXXXXXX: Data Station No.

    00 : ASCII (7-bit) + even parity

    01 : ASCII (7-bit) + odd parity

    02 : ASCII (7-bit) + parity (0)

    03 : ASCII (7-bit) + parity (1)

    04 : JIS (7-bit) + even parity

    05 : JIS (7-bit) + odd parity

    06 : JIS (8-bit)

    07 : EBCDIC (8-bit)

    15 : Non character (Binary Data)

    (1)

    (2)

    YY=19 S Buffer

    X-XXXXXXXX: Data Station No.

    0 : Effective

    1 : Ineffective

    Provide the Nailed-Down Connection with

    the connecting patterns.

    (1)

    (2)

    YYY=00-99, 000-199

    Memory Block 00-99, 000-199

    X-XXXXXXXX: Data station No.

    assigned byCM1A

    DXXX : Trunk No.

    assigned

    by CM07

    X-XXXXXXXX: Data station No.

    assigned by

    CM1A

    DXXX : Trunk No.

    assigned

    by CM07

    CMA1

    B

    END

    CMA5

    1ST

    DATA

    (1)

    2ND

    DATA

    (2)

    Data station to Data

    station

    X-XXXX

    XXXX

    X-XXXX

    XXXX

    Data station to trunk X-XXXX

    XXXXDXXX

    Trunk to trunk

    (Tandem Connection)DXXX DXXX

    1ST AND 2NDDATA

    CONNECTINGPATTERN

    Seelefttable

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    58/100

    NEAX2000 IVS2 Data Interface System ManualPage 50 ND-70924 (E), Issue 1.0

    CHAPTER 3 SYSTEM DATA PROGRAMMINGDigital Trunk Interface Assignment

    DIGITAL TRUNK INTERFACE ASSIGNMENT

    DESCRIPTION DATA

    Assign an AP number to the DTI card.

    The AP number must match the SENSEswitch setting on the DTI card.

    (1)(2)

    Y=0

    04-15, 20-31: AP No.09: DTI

    Specify the AP highway channel for

    24DTI card.

    (1)

    (2)

    Y=1

    04-15, 20-31: AP No.

    0 : Expanded Highway channel

    (128 time slots)

    1 : Basic Highway channel

    (128 time slots)

    Assign trunk numbers to each channelnumber on the DTI card.

    The system allocates time slots to

    consecutive channels from the lowest to

    the highest channel number assigned. To

    minimize the number of time slots

    allocated, assign trunk numbers to

    consecutive channels on each card.

    Never skip channels in CM07.

    (1)

    (2)

    YY=01XX ZZ

    XX: 04-15, 20-31: AP No. assigned by

    CM05 Y=0

    ZZ: 00-23: Channel No. of 24DTI

    01-15, 17-31: Channel No. of

    30DTI

    D000-D255: Trunk No.

    Any trunk number already assigned by

    CM10 cannot be used.

    CM07

    START

    CM05

    A

    INITIAL

    INITIAL

    INITIAL

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    59/100

    CHAPTER 3 SYSTEM DATA PROGRAMMINGDigital Trunk Interface Assignment

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 51

    DESCRIPTION DATA

    Assign the necessary functions to the

    24DTI card.

    After entering the data, set the MB switch

    on the DTI card to UP, and then to

    DOWN, for DTI initialization.

    (1)

    (2)

    (1)

    (2)

    (1)

    (2)

    (1)

    (2)

    YY=00 Data Mode

    04-15, 20-31: AP No. assigned byCM05 Y=0

    0: Based on AT&T Spec.

    YY=01 Frame Configuration

    04-15, 20-31: AP No. assigned by

    CM05 Y=0

    0 : 12-Multi Frame

    1 : 24-Multi Frame

    YY=02 Zero Code Suppression

    04-15, 20-31: AP No. assigned byCM05 Y=0

    1 : Not available (Transparent)

    YY=03

    04-15, 20-31: AP No. assigned by

    CM05 Y=0

    7 : Associated Channel Interoffice

    Signaling

    Assign a trunk route number for tie line

    interface to each DTI.

    NOTE: The DTI route must be separatedfrom any analog trunk route.

    (1)

    (2)

    YY=00

    000-255: Trunk No. assigned by CM07Y=01

    00-63: Trunk Route No.

    Assign trunk route data to each DTI route.

    (1)

    (2)

    YY=00 Kind of Trunk Route

    00-63: Trunk Route No.

    04: Tie Line trunk

    (1)

    (2)

    YY=01 Dialing Signal Type

    00-63: Trunk Route No.

    7 : DP/DTMF (Incoming)DTMF (Outgoing)

    CMAA

    A

    CM30

    CM35

    B

    DTI INITIAL

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    60/100

    NEAX2000 IVS2 Data Interface System ManualPage 52 ND-70924 (E), Issue 1.0

    CHAPTER 3 SYSTEM DATA PROGRAMMINGDigital Trunk Interface Assignment

    DESCRIPTION DATA

    CM35 Y=19 DTI PAD

    [For Australia]

    [For North America/Other Countries]

    (1)

    (2)

    YY=04

    Answer Signal from distant office00-63: Trunk Route No.

    2: Answer signal arrives

    (1)

    (2)

    YY=05

    Release Signal from distant office

    00-63: Trunk Route No.

    1 : Release signal arrives

    (1)

    (2)

    YY=09 Incoming Connection Signaling

    00-63: Trunk Route No.

    03: Wink Start

    04: Delay Dial

    05: Immediate Start

    06: 2nd DT/Timing Start-Tie Line

    (1)

    (2)

    YY=19 DTI Pad

    00-63: Trunk Route No.

    0-3: Programmable PAD by CM42

    4-7 : Fixed PAD (See left table)

    (1)

    (2)

    YY=20 Sender start condition

    00-63: Trunk Route No.

    00 : Wink Start01 : Delay Dial

    02 : Ground Start

    15 : Timing Start

    (1)

    (2)

    YY=89 Cyclic Redundancy Checking

    for Bit Error Detection

    00-63: Trunk Route No.

    0: To provide

    CM35

    B

    C

    T/R: Transmitter PAD/Receiver PAD

    CONNECTION

    PATTERNS

    PAD DATA OF DTI [dB]

    DATA

    =4

    (T/R)

    DATA

    =5

    (T/R)

    DATA

    =6

    (T/R)

    DATA

    =7

    (T/R)

    Station-DTI 0/0

    Tone-DTI 0/0

    COT/DID/LDT-DTI 0/0

    ODT-DTI 0/0

    DTI-DTI 0/0

    T/R : Transmitter PAD/Receiver PAD

    + : Gain

    : Loss

    CONNECTIONPATTERNS

    PAD DATA OF DTI [dB]

    DATA=4 (T/R)

    DATA=5 (T/R)

    DATA=6 (T/R)

    DATA=7 (T/R)

    Station-DTI 3/8 3/3 3/3 3/8

    Tone-DTI 0/0 0/0 0/0 0/0

    COT/DID/LDT/ODT(2W E&M)-DTI

    0/0 0/0 0/0 0/0

    ODT (4W E&M)-DTI

    +3/3 0/0 0/0 +3/3

    DTI-DTI 0/6 0/0 0/6 0/0

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    61/100

    CHAPTER 3 SYSTEM DATA PROGRAMMINGDigital Trunk Interface Assignment

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 53

    DESCRIPTION DATA

    Specify the kind of digital data

    transmission.

    (1)(2)

    YY=92

    00-63: Trunk Route No.

    0 : Digital Data Transmission

    (48 kbps)

    1 : Digital Data Transmission

    (56 kbps)

    2 : Digital Data Transmission

    (Transparent)

    3 : Reversal of F&S Bits

    7 : Data Transmission via Modem

    CM35

    C

    END

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    62/100

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 55

    CHAPTER 4

    OPERATION TEST

    This chapter explains the operation tests to be performed after you

    have completed the installation of the Data Interface to the PBX.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    63/100

    NEAX2000 IVS2 Data Interface System ManualPage 56 ND-70924 (E), Issue 1.0

    CHAPTER 4 OPERATION TESTDPC Loopback Test

    DPC LOOPBACK TEST

    This test is the intra-office loopback test on the DPC card using a modem tester. There are two

    kinds of loopback (Loopback 1, Loopback 2) as shown in Figure 4-1. Either the Loopback 1 or

    the Loopback 2 can be selected by switch settings on the DPC card.

    Figure 4-1 DPC Loopback Tests

    V.110

    DPC

    V.110

    DPC

    Loopback 1 PBX

    MODEM TESTER

    DTI

    Loopback 2

    MODEM TESTER

    DTI

    NOTE: The modem tester is locally provided.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    64/100

    CHAPTER 4 OPERATION TESTDPC Loopback Test

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 57

    DPC Loopback 1 Test

    (1) Set the SW1 on the DPC card as shown below.

    (2) Confirm whether the LB01 lamp (for No. 0 circuit) or the LB11 lamp (for No. 1 circuit) on the

    DPC card lights.

    If the LB01 lamp or the LB11 lamp does not light, check the switch settings on the DPC card

    and the system data assignment.

    (3) Connect a modem tester to the DPC card as shown in Figure 4-2.

    Figure 4-2 Connection of Modem Tester

    For No. 0 Circuit For No. 1 Circuit

    4

    3

    2

    1

    OFF

    ON

    SW1

    4

    3

    2

    1

    OFF

    ON

    SW1

    : POSITION TO BE SET

    MODEM TESTER

    DPC

    PBX

    (J) (P)

    STRAIGHT CABLE DPC V11 CABLE

    (P) (J)

    XCN0 (FOR No. 0 CIRCUIT)/XCN1 (FOR No. 1 CIRCUIT)

    (a) When you use V. 11 (X.21) interface

    MODEM TESTER

    DPC

    PBX

    (J) (P)

    STRAIGHT CABLE DPC RS CABLE

    (P) (J)

    RS0 (FOR No. 0 CIRCUIT)/RS1 (FOR No. 1 CIRCUIT)

    (b) When you use V. 24/V. 28 (RS-232C) interface

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    65/100

    NEAX2000 IVS2 Data Interface System ManualPage 58 ND-70924 (E), Issue 1.0

    CHAPTER 4 OPERATION TESTDPC Loopback Test

    (4) Set the attributes of modem tester (transmission rate, etc.).

    (5) To confirm whether the data is transmitted correctly, send the PN Pattern 9 (511 Pattern)

    from the modem tester.

    (6) Count bit errors on the modem tester for 1 minute.

    If bit errors do not occur, the cable connection between DPC card and modem tester is

    normal.

    (7) If bit errors occur, check the cable connection, and replace the DPC card.

    (8) After this test, set all the SW1-1 through SW1-4 on the DPC card to OFF.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    66/100

    CHAPTER 4 OPERATION TESTDPC Loopback Test

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 59

    DPC Loopback 2 Test

    After you complete the DPC Loopback 1 Test, do the following steps.

    (1) Set the SW1 on the DPC card as shown below.

    (2) Confirm whether the LB02 lamp (for No. 0 circuit) or the LB12 lamp (for No. 1 circuit) on theDPC card lights.

    If the LB02 lamp or the LB12 lamp does not light, check the switch settings on the DPC card

    and the system data assignment.

    (3) Connect a modem tester to the DPC card as shown in Figure 4-2 Connection of Modem

    Tester.

    (4) Set the attributes of modem tester (transmission rate, etc.).

    (5) To confirm whether the data is transmitted correctly, send the PN Pattern 9 (511 Pattern)

    from the modem tester.

    (6) Count bit errors on the modem tester for 1 minute.

    If bit errors do not occur, the DPC card is normal.

    (7) If bit errors occur, check the system data assignment, and replace the DPC card.

    (8) After this test, set all the SW1-1 through SW1-4 on DPC card to OFF.

    For No. 0 Circuit For No. 1 Circuit

    4

    3

    2

    1

    OFF

    ON

    SW1

    4

    3

    2

    1

    OFF

    ON

    SW1

    : POSITION TO BE SET

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    67/100

    NEAX2000 IVS2 Data Interface System ManualPage 60 ND-70924 (E), Issue 1.0

    CHAPTER 4 OPERATION TESTOther Loopback Tests

    OTHER LOOPBACK TESTS

    Two additional forms of loopback test are shown in Figure 4-3.

    Figure 4-3 Other Loopback Tests

    V.110

    DPC

    DTI local loopback PBX

    DTI

    DTI hard-wired loopback

    Set DTI in localloopback.

    DTI

    TATB

    RARB

    On the MDF, connect

    transmit leads to the

    Receive leads to test

    all portions of the DTI.

    V.110

    DPC

    MODEM TESTER

    MODEM TESTER

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    68/100

    CHAPTER 4 OPERATION TESTInter-Office Digital Data Transmission Test

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 61

    INTER-OFFICE DIGITAL DATA TRANSMISSION TEST

    This test is the inter-office digital data transmission test using modem testers. After you complete

    the loopback tests, do the following steps.

    (1) Connect modem testers to the both PBXs as shown in Figure 4-4.

    Figure 4-4 Inter-Office Digital Data Transmission Test

    (2) Set the attributes of both modem testers (transmission rate, etc.).

    NOTE: If both the attributes do not match, this test is not available.

    (3) To confirm whether the data is transmitted correctly, send the PN Pattern 9 (511 Pattern)

    from the modem testers.

    (4) Count bit errors on the modem testers for 1 minute.

    If bit errors do not occur, the inter-office digital data transmission is normal.

    (5) If bit errors occur, check the following items.

    System data assignment DTI card

    PCM digital line

    Opposite PBX

    PBXPBX

    MODEM TESTER

    DTIDPC DTI DPC

    MODEM TESTER

    24/30 CHANNELPCM DIGITAL LINE

    NOTE 1: For details of cable connection between the DPC card and the modem tester, see

    Figure 4-2 Connection of Modem Tester.

    NOTE 2: The modem tester is locally provided.

    NOTE 1 NOTE 1

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    69/100

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 63

    CHAPTER 5

    CIRCUIT CARDINFORMATION

    This chapter explains the mounting location, the meaning of lamp

    indications, and the method of switch settings of each circuit card for

    the Data Interface system.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    70/100

    NEAX2000 IVS2 Data Interface System ManualPage 64 ND-70924 (E), Issue 1.0

    CHAPTER 5 CIRCUIT CARD INFORMATIONHow to Read This Chapter

    HOW TO READ THIS CHAPTER

    This chapter explains each circuit card used in this system for the following items. Explanations

    are given in the alphabetical order of the circuit card names within each circuit card category

    (Control, Application Processor, and Line/Trunk).

    (1) Locations of Lamps, Switches, and Connectors

    The locations of lamps, switches, and connectors of each circuit card are shown by a face

    layout.

    (2) Lamp Indications

    The name, color, and functions of each indicator lamp equipped on each circuit card are

    described in a table.

    (3) Switch Settings

    The name, settings, and functions of each switch equipped on each circuit card are

    described in a table.

    Each switch setting table has a CHECK column. Make necessary entries in the CHECK column

    during and/or after the system installation and maintenance, and use each table as a reference

    for subsequent system maintenance and operations.

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    71/100

    CHAPTER 5 CIRCUIT CARD INFORMATIONMounting Location of Circuit Card

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 65

    MOUNTING LOCATION OF CIRCUIT CARD

    This section explains the conditions for mounting circuit cards for the Data Interface.

    Figure 5-1 shows circuit card mounting slots allocated in the PIM.

    Figure 5-1 Mounting Location of Circuit Card

    *1 PN-CP14 (MP) card on the MP12 slot on PIM0.

    *2 PN-24DTA-C/PN-30DTC-A (DTI) card on the AP00-AP11 slots on PIM0-PIM7.

    *3 PN-2DPCB (DPC) and PN-M03 (M03) card on the LT00-LT11 slots on PIM0-PIM7.

    *4 PZ-M542/PZ-M557 (CONN) card on the LTC0-LTC3 connectors on the PIM which

    accommodates 30DTI card.

    LT09/AP09

    LT08/AP08

    LT07/AP07

    LTC1LTC0 LTC2

    BWB

    PIM

    0~7

    FRONT

    AC/DC

    PWR

    LT10/AP10

    LT00/AP00

    LT01/AP01

    LT02/AP02

    LT03/AP03

    LT04/AP04

    LT05/AP05

    LT06/AP06

    LT11/AP11/FP11

    MP12/FP12

    LTC3

    DC/DC

    PWR

    PFT

    VM

    *2, *3*1

    *4

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    72/100

    NEAX2000 IVS2 Data Interface System ManualPage 66 ND-70924 (E), Issue 1.0

    CHAPTER 5 CIRCUIT CARD INFORMATIONList of Required Circuit Cards

    LIST OF REQUIRED CIRCUIT CARDS

    Table 5-1 shows the required circuit cards to be explained in this section.

    *MB = Make Busy

    Table 5-1 List of Required Circuit Cards

    NAME

    (FUNCTIONAL

    NAME)

    LAMP

    X:PROVIDED

    : NOT

    PROVIDED

    SWITCH

    X:PROVIDED

    : NOT

    PROVIDED

    EXTRACTION/

    INSERTION WITH

    POWER ON

    X:ALLOWED

    : ALLOWED

    AFTER MB*

    : NOT ALLOWED

    REFERENCE

    PAGE

    PN-CP14 (MP) X X Page 67

    PN-24DTA-C (DTI) X X Page 72

    PN-30DTC-A (DTI) X X Page 78

    PZ-M542 (CONN) X X Page 84

    PZ-M557 (CONN) X X Page 86

    PN-2DPCB (DPC) X X X Page 88

    PN-M03 (M03) X X X Page 92

  • 7/30/2019 NEAX2000 IVS2 Data Interface System Manual

    73/100

    CHAPTER 5 CIRCUIT CARD INFORMATIONList of Required Circuit Cards

    NEAX2000 IVS2 Data Interface System ManualND-70924 (E), Issue 1.0 Page 67

    PN-CP14 (MP)

    Locations of Lamps, Switches, and Connectors

    CONN: To CONNR connector on PZ-M537 (EXPMEM)

    Lamp Indications

    LAMP

    NAMECOLOR FUN