Top Banner
Tillison Photography 1141 Sugar Hill Drive Rushville, IN 46173 765-932-4025 1/19 Tillison Photography / Thermal Imaging My House Thermal Audit Feb, 2012 Inside only
19

My House Thermal Audit Feb. 2012

Jul 14, 2015

Download

Art & Photos

miketillison
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

1/19 Tillison Photography / Thermal Imaging

My HouseThermal Audit Feb, 2012Inside only

Mike
Text Box
Note: A thermal camera only detects heat, even an ice cube has heat. Thermal cameras are completely safe utilizing a special lens to detect ranges of temperature. In this report you will see a thermal image along with a regular photo to help know the location the photographs are taken. Each thermal image will contain a scale on the right side of the photograph that will show the maximum and the minimum temperature in that photograph. The brighter the color equal hotter... The darker the color equals cooler temperature. Some photographs will have additional Lines, squares or circles in them. This is an additional measurement tool with the hottest and coldest spot marked in that area. More information about that tool will be listed on the left side of that page.
Page 2: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

2/19 Tillison Photography / Thermal Imaging

2/17/2012 3:46:35 PM

69.4

62.1

IR_0297.jpg

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 3:46:35 PM

DC_0298.jpg

Front RoomAll exterior walls at corners and at ceiling need insulation

Page 3: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

3/19 Tillison Photography / Thermal Imaging

2/17/2012 3:46:50 PM

Li1

85.6

52.0

IR_0299.jpg

Measurements °FLi1 Max

Min

Average

66.0

52.3

59.5

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 3:46:50 PM

DC_0300.jpg

Dining RoomAc unit

Page 4: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

4/19 Tillison Photography / Thermal Imaging

2/17/2012 3:50:05 PM

66.2

58.0

IR_0305.jpg

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 3:50:05 PM

DC_0306.jpg

Dining RoomOutside east wall

Page 5: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

5/19 Tillison Photography / Thermal Imaging

2/17/2012 3:51:22 PM

68.5

61.2

IR_0309.jpg

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 3:51:22 PM

DC_0310.jpg

KitchenUnder sink

Page 6: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

6/19 Tillison Photography / Thermal Imaging

2/17/2012 3:51:48 PM

Li1

66.5

53.9

IR_0311.jpg

Measurements °FLi1 Max

Min

Average

66.2

53.4

60.7

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 3:51:48 PM

DC_0312.jpg

Back Doorwooden door / No Insulation

Page 7: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

7/19 Tillison Photography / Thermal Imaging

2/17/2012 3:55:34 PM

El1

69.5

62.2

IR_0321.jpg

Measurements °FEl1 Max

Min

Average

68.1

62.9

66.4

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 3:55:34 PM

DC_0322.jpg

Attic door

Page 8: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

8/19 Tillison Photography / Thermal Imaging

2/17/2012 3:55:52 PM

67.5

48.5

IR_0323.jpg

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 3:55:52 PM

DC_0324.jpg

BathroomWindow and frame

Page 9: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

9/19 Tillison Photography / Thermal Imaging

2/17/2012 3:56:16 PM

El1 67.2

59.9

IR_0325.jpg

Measurements °FEl1 Max

Min

Average

65.7

60.9

63.6

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 3:56:16 PM

DC_0326.jpg

Bathroom

Page 10: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

10/19 Tillison Photography / Thermal Imaging

2/17/2012 3:56:41 PMAr1

66.9

59.5

IR_0327.jpg

Measurements °FAr1 Max

Min

Average

67.1

59.8

64.1

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 3:56:41 PM

DC_0328.jpg

Back BedroomMissing insulation

Page 11: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

11/19 Tillison Photography / Thermal Imaging

2/17/2012 3:59:19 PM

El1

67.6

60.2

IR_0333.jpg

Measurements °FEl1 Max

Min

Average

66.8

60.8

64.3

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 3:59:19 PM

DC_0334.jpg

Back OfficeWest Wall

Page 12: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

12/19 Tillison Photography / Thermal Imaging

2/17/2012 4:00:22 PM

El1

66.0

58.6

IR_0335.jpg

Measurements °FEl1 Max

Min

Average

65.8

58.1

63.6

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 4:00:22 PM

DC_0336.jpg

Back OfficeCloset west wall

Page 13: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

13/19 Tillison Photography / Thermal Imaging

2/17/2012 4:03:51 PM

El1

69.4

62.1

IR_0347.jpg

Measurements °FEl1 Max

Min

Average

68.0

63.4

65.9

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 4:03:51 PM

DC_0348.jpg

Bedroom mainNorth wall

Page 14: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

14/19 Tillison Photography / Thermal Imaging

2/17/2012 4:04:29 PM

68.0

60.7

IR_0351.jpg

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 4:04:29 PM

DC_0352.jpg

BedroomNorth wall and ceiling

Page 15: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

15/19 Tillison Photography / Thermal Imaging

2/17/2012 4:05:01 PM

Ar197.2

65.7

IR_0353.jpg

Measurements °FAr1 Max

Min

Average

97.6

66.0

72.3

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 4:05:01 PM

DC_0354.jpg

Bedroom MainWeather radio power supply

Page 16: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

16/19 Tillison Photography / Thermal Imaging

2/17/2012 4:08:50 PM

El1

59.2

47.4

IR_0357.jpg

Measurements °FEl1 Max

Min

Average

58.3

46.1

53.2

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 4:08:50 PM

DC_0358.jpg

BasementAll windows

Page 17: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

17/19 Tillison Photography / Thermal Imaging

2/17/2012 4:11:29 PM

El1

67.9

53.0

IR_0363.jpg

Measurements °FEl1 Max

Min

Average

67.6

52.0

62.7

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 4:11:29 PM

DC_0364.jpg

BasementMissing insulationPossible water leak !!

Page 18: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

18/19 Tillison Photography / Thermal Imaging

2/17/2012 4:12:02 PM

63.0

49.8

IR_0365.jpg

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 4:12:02 PM

DC_0366.jpg

BasementNo Insulation in ceiling

Page 19: My House Thermal Audit  Feb. 2012

Tillison Photography1141 Sugar Hill DriveRushville, IN 46173765-932-4025

19/19 Tillison Photography / Thermal Imaging

2/17/2012 4:16:28 PM

Ar1

73.0

63.5

IR_0375.jpg

Measurements °FAr1 Max

Min

Average

73.4

63.8

68.0

ParametersEmissivity: 0.86

Refl. apparent temp.: 68 °F

2/17/2012 4:16:28 PM

DC_0376.jpg

BasementHeat at bricks and upper floor