PCRAU0726B Multi-Split Type Air Conditioners E Series with DC Inverter Power Control Cooling Only & Heat Pump [50 Hz] Connectable to max. 9 indoor units H a r m o n y i n t h e a i r
44

Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

Mar 27, 2019

Download

Documents

lamhanh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

PCRAU0726B

Multi-Split Type Air Conditioners E Serieswith DC Inverter Power ControlCooling Only & Heat Pump [50 Hz]

Connectable to max. 9 indoor units

Harmony in the air

Page 2: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

1

• Connectable to max. 9* indoor units

Daikin’s Super Multi PLUS E series is connectable to up to 9 indoor units and offers you a richer choice of indoor units to coordinate with each room décor. Advanced technology from Daikin has achieved a high COP and low sound level to suit today’s modern living environment.

An 11.2 to 15.5 kW Multi-Split system

* Combination is possible with 15.5 kW class outdoor unit and 2.0 kW class indoor units.

NewDesign

Page 3: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

2

that suits large and luxurious houses

Main features of Daikin’s SUPER MULTI PLUS

3 models of outdoor units are available in the wide range of 11.2, 14 and 15.5 kW classes. A maximum of 9* indoor units can be connected.

Wide range of outdoor units

32 models of indoor units grouped into 7 types (heat pump)—ceiling-mounted cassette, ceiling-mounted built-in, ceiling-suspended, duct-connected, wall-mounted, floor-standing, and floor/ceiling-suspended dual types—provide a wide range of options for interior coordination.

Wide variety of indoor units

The scroll compressor, DC inverter and DC fan motor technologies realise energy savings, achieving high COP values.

High energy savings

Great flexibility in installation

Quiet operation

* Combination is possible with 15.5 kW class outdoor unit and 2.0 kW class indoor units.

Long piping lengths of 145 m for the 15.5 kW class outdoor unit and simplified wiring reduce restrictions on the installation position.

Latest technologies and features achieve the quiet sound level of 43 dB (A) during night quiet mode operation for outdoor units, realising comfortable operation.

Page 4: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

3

Wide range of choicesWide range of choices

A wide range of both indoor and outdoor units

The outdoor unit can be selected from three models for the precise power to suit the size of house, shop or office.

3 models11.2 kW, 14 kW, 15.5 kW

Outdoor unit

To suit every room in large houses, small shops and small offices, the Super Multi PLUS E series offers a wide range of indoor and outdoor units.

32 models 7 types (heat pump)Indoor unit

RMK(X)S112EV1A (11.2 kW)

RMK(X)S140EV1A (14 kW)

RMK(X)S160EV1A (15.5 kW)

600 x 600

Type

Ceiling-mounted cassette type

Wall-mounted type

Floor-standing type

Floor/ceiling-suspended dual type

Ceiling-mounted built-in type

Duct-connected type

Ceiling-suspended type

Model name 202.0

252.5

353.5

505.0

606.0

717.1

202.0

252.5

353.5

505.0

606.0

717.1Rated capacity (kW)

Cooling only Heat pump

FCQ-B

FFQ-B

FBQ-B

FHQ-B

CDKS-EA(700 mm

width type)

FTKS-G

FTKS-J

Model nameRated capacity (kW)

FCQ-B

FFQ-B

FBQ-B

FHQ-B

CDXS-EA(700 mm

width type)

FTXS-G

FTXS-J

FVXS-G

FLXS-B

A wide range of indoor units includes 32 heat pump models in 7 types and 25 cooling only models in 5 types. Indoor units can be selected to match each room and preference.

FTKS-D FTXS-D

CDKS-C(900/1,100 mm

width type)

FDXS-C(900/1,100 mm

width type)

FLXS-G

NewDesign

Page 5: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

4

A wide variety of stylish indoor units

Ceiling-mounted cassette type Ceiling-mounted built-in type

Duct-connected typeCeiling-suspended type

Floor/ceiling-suspended dual type

Wall-mounted type Floor-standing type

Page 6: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

5

The Super Multi PLUS E series outdoor units use the latest technologies to realise energy saving performance and quiet operation.

Energy efficiency and quiet operationEnergy efficiency and quiet operation

RMXS160E

Master bedroom 3.5 kW class

Bedroom (1) 2.0 kW class

Bedroom (2) 2.5 kW class

Cooling operation Heating operation

Power consumption 2,040 W

COP 3.82

Power consumption 2,620 W

COP 3.55

High Energy Savings

During night time

With DC inverter power control the air conditioner can operate at low capacity most of the time. This is especially important at night in a residential situation when the whole family is at home. DC inverter power control is able to achieve a high COP even when multiple indoor units operate simultaneously for long periods of time.

Quiet operation features that achieve total comfort

Quietness is yet another important feature of Daikin’s Super Multi PLUS E series. To reduce sound and realise comfortable operation, latest technologies and features are applied to the outdoor units, achieving the quiet operating sound level of 43 dB (A) in night quiet mode.

Night quiet mode

Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will become active 8 hours*1 after the peak temperature in the daytime, and operation will return to normal 10 hours*2 after that. The operation sound level for the night mode can be selected from 49 dB (A) (Step 1), 46 dB (A) (Step 2) and 43 dB (A) (Step 3).

Automatic modeMode 1. Automatic modeMode 1.

Starting time and ending time can be input. (External control adaptor for outdoor unit, DTA104A61 or DTA104A62, and a subsequently obtained timer are necessary.)

Manual modeMode 2.

Combination of mode 1 and 2 can be used depending on your needs.

Combined modeMode 3.

*1. Initial setting. Can be selected from 6, 8 and 10 hours.*2. Initial setting. Can be selected from 8, 9 and 10 hours.

Notes: • This function is available in setting at site.

• The relationship of outdoor temperature (load) and time shown in the graph is just an example.

Peak in the outdoor temperature

Capa

city

%

8 hrs 10 hrs

Oper

atio

n so

und

dB (A

)

49

8:00 12:00 16:00 20:00 0:00 4:00 8:00

50

100

520

Load

%

Night modeNight mode endsendsNight modeNight mode startsstarts Night mode endsNight mode starts

Night Mode

46

43

(Initial setting)(Initial setting)

Step 1 max. - 3dB (A)(11.2 kW)

Step 2 max. - 6dB (A)(11.2 kW)

Step 3 max. - 9dB (A)(11.2 kW)

Step 1: 49 dB (A)

Step 2: 46 dB (A)

Step 3: 43 dB (A)

Operation sound level selectablefrom 3 steps for the night mode

The capacity reduction rate differs depending on the operation sound level step selected.

Page 7: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

6

These two features work to significantly reduce sound. Guides are added to the bell mouth intake to reduce turbulence in the airflow generated by fan suction. The Aero Spiral Fan features fan blades with the bent blade edges, further reducing turbulence.

Smooth Air Inlet Bell Mouth and Aero Spiral Fan

A larger sub-cooled area reduces refrigerant flow sound by making it easer to form a liquid seal in front of the electrical valve.

SC heat exchanger

Super Aero Grille Refined ventilation mechanism enables further reduction in required fan power.

Escaping eddies are sucked in by the bent blade edges, reducing overall turbulence.

A collection of cutting-edge technologies realises efficient and quiet operation.

Improving the high efficiency compressor to achieve a higher COP

2

5

1

Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory.

DC fan motorEfficiency improved in all areas compared to conventional AC motors, especially at low speeds.

4

Sine wave DC inverter

>> Smooth sine wave DC inverter Use of an optimised sine wave smoothes motor rotation, further improving operating efficiency.

Use of neodymium magnets in the motor enables efficient generation of high torque, reducing the size of the compressor.

>> Powerful magnets

Changes to the shape of the spiral and volume ratio result in optimal refrigerant layout.

>> Optimal refrigerant configurationThe strength of the casing has been increased by boosting the internal dome pressure.

>> Stronger materials

Overheating losses are reduced by pressurising the area around the motor, boosting energy saving performance in conjunction with other features.

Reluctance DC Scroll Compressor

3DC motor efficiency

(Comparison with a conventional AC motor)

200 300 400 500 600 700 800 900 1000

0

20

40

80

60

100

Eff

icie

ncy

(%

)

Motor speed (rpm)

AC motorAC motorAC motorAC motorAC motorApprox.

40%increase

Approx.

20%increase

DC motorDC motorDC motorDC motorDC motorDC fan motor structure

RMK(X)S112ERMK(X)S140ERMK(X)S160E

ReluctanceDC motor

By introducing high pressure oil, the reactive force from the fixed scroll is added to the internal force, thereby reducing thrust losses. This results in improved efficiency and suppressed sound levels.

High thrust mechanism

3

4 1

5

2

With the bent blade edge

Without the bent blade edge

Page 8: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

7

A BP unit is an innovative development which allows Super Multi Plus outdoor units to be connected to a wide range of different indoor unit types. A BP unit has the ability to precisely vary refrigerant volume to meet the cooling requirements of individual room spaces.

Optional REFNET joint: KHRP26A22T

3 ports BPMKS967A3

2 ports BPMKS967A2

The REFNET joint both reduces the amount of work involved in installation and increases the reliability of the system.

Total main piping length

Total branch piping length

Total main and branch piping length

55 m90 m

145 m (55 + 90)

BP unit REFNET joint

A maximum total piping length of 145 m offers flexibility in the choice of installation positions for the indoor units, and greatly simplifies system planning.

The Super Multi PLUS E Series is connectable to up to 9 indoor units. While the BP unit and the REFNET joint make installation simple, long piping length and simplified wiring broaden design flexibility.

Design flexibility and easy installationDesign flexibility and easy installation

Thin refrigerant piping makes handling and connecting easier, resulting in significantly reduced installation time.

As many as 9 indoor units can be connected to a single outdoor unit

Long refrigerant piping

Piping length for RMK(X)S160E

Note: Refrigerant charge is required. (Chargeless piping length 0 m)

>> 8 indoor units for a 14 kW installation >> 6 indoor units for a 11.2 kW installation

30 mMax. height difference

Main piping

BP unit

BP unit

Branch piping

Branch piping

For outdoor unit 15.5 kW installation

units9

1 2 3

4 5 6

7 8

Page 9: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

8

The outdoor unit and the BP units operate from separate single-phase power supplies, so no power supply wiring is needed between them. The size of the wiring pipe from the outdoor unit to the BP units can be reduced, making installation easier.

Simplified electrical wiring connection

The outdoor unit’s heat exchanger fins are processed using a special anticorrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins’ resistance to acid rain and salt corrosion. A hydrophilic film layer also prevents rust caused by the run off of water droplets. Additional durability is provided by a rustproof steel sheet on the bottom of the unit.

Durable outdoor unitA single high-capacity outdoor unit can drive up to 9 indoor units, making it powerful enough to air-condition a whole residence. This powerful unit can be easily installed on a balcony with its slimline design, which measures (H) 1,345 x (W) 900 x (D) 320 mm.

Space saving

The Super Multi PLUS has the wide operation range required for commercial-use air-conditioning systems. So even when the outdoor temperature drops to –5 C, cooling operation is still available if the temperature rises rapidly in a crowded room.

Wide Operation Range

BP unit(2 ports)

Outdoor unit

Safety breaker

Powersupply

Powersupply

BP unit(2 ports)

BP unit(3 ports)

30 A

15 A

Transmission line (4 lines)

(Indoor unit--BP / including earth wire)

Earth wire

Earth wire

Earth leakage circuit breaker

Safety breaker

Earth leakage circuit breaker

D transmission line (2 lines)

(Outdoor unit--BP, BP--BP)

Heat exchanger fin

Hydrophilic film

Aluminium

Corrosion-resistantacrylic resin

Cross section of anticorrosion-treated fin

900 mm 320 mm

1,345 mm

-10

0

10

20

30

40

50

-20

-10

0

10

20 15.5°C WB

Heating

46°C DB

Cooling

-5°C DB–15°C WBO

utdo

or te

mpe

ratu

re (°

C D

B)

Out

door

tem

pera

ture

(°C

WB

)

Page 10: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

9

Central remote controllerDCS302CA61

Unified on/off controllerDCS301BA61

Schedule timerDST301BA61

5-room centralised controllerKRC72

• Max. 64 groups controllable• Zone control• Malfunction code display

64 groups (zones) of indoor units can be controlled individually same as LCD remote controller.

• Max. 16 groups controllable• Operating status indication• Centralised control indication

16 groups of indoor units can be operated simultaneously/individually.

• Max. 128 indoor units controllable• The start and stop time for twice a day can be set for the week in a unit of one minute.

128 indoor units can be operated on a 7-day programmed schedule.

• Max. 5 indoor units controllable• Contribute to save energy by eliminating turn-off of lamps.

5 indoor units can be controlled. This is a low cost system which can only control about on/off.

Central remote controller (option)

Unified on/off controller (option)

Schedule timer (option)

5-room centralised controller (option)

Centralised Control systemCentralised Control systemBoth Super Multi PLUS and VRV systems are compatible with the Building Air-Conditioning Control System. This allows Super Multi PLUS and VRV units to be conveniently operated from the same common controller when the two systems are installed together in a building.

Compatible indoor units

FCQ, FFQ C(F)DK(X)SFBQ FTK(X)SFHQ FVXS FLXS

Central remote controller*1

Unified on/off controller*1

Schedule timer*1

5-room centralised controller*2

Notes: *1. An interface adaptor (KRP928B2S or DTA112B51) is also required for each indoor unit.*2. A wiring adaptor (KRP413A1S) is also required for each indoor unit.

Page 11: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

10

Indoor unit lineupIndoor unit lineupType

Ceiling-mounted cassette type

Wall-mounted type

Floor-standing type

Floor/ceiling-suspended dual type

Ceiling-mounted built-in type

Duct-connected type

Ceiling-suspended type

Model name 20

2.0

25

2.5

35

3.5

50

5.0

60

6.0

71

7.1

20

2.0

25

2.5

35

3.5

50

5.0

60

6.0

71

7.1Rated capacity (kW)

Model name

Rated capacity (kW)

Cooling only Heat pump

FCQ-B

FFQ-B

FBQ-B

FHQ-B

CDKS-C(900/1,100 mm

width type)

FTKS-J

FTKS-G

FCQ-B

FFQ-B

FBQ-B

FHQ-B

FDXS-C(900/1,100 mm

width type)

FTXS-G

FTXS-J

FVXS-G

FLXS-B

FTKS-D FTXS-D

CDKS-EA(700 mm

width type)

CDXS-EA(700 mm

width type)

FLXS-G

600 x 600

NewDesign

Page 12: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

11

Ceiling-mounted cassette (multi flow) Ceiling-mounted cassette (multi flow)

3.5 kW class

FCQ35BVE

FCQ35BVE

5.0 kW class

FCQ50BVE

FCQ50BVE

6.0 kW class

FCQ60BVE

FCQ60BVE

7.1 kW class

FCQ71BVE

FCQ71BVE

The ideal air conditioner for installation inside narrow false ceilings—with only the decoration panel visible after installation. A simple design makes it comfortable to the public eye in shops and small offices in tenant buildings, as well as right at home in the living rooms with false ceilings found in multi-storey apartment blocks.

Specially designed for false ceilings—for a smooth, modern interior finish

Option

Signal receiver unitNote: Wireless remote controllers and signal receiver units are sold as a set.

OptionNote: Remote controller cables not included. Cables should beobtained locally.

Coolingonly

Heatpump

Page 13: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

12

typetype

Comfort and quietness

Standard: a swing range of 10 to 65 Draft prevention: a limited swing range of 10 to 40 prevents airflow from blowing directly onto people.Soiling prevention: a limited swing range of 30 to 65 prevents ceilings from becoming dirty due to direct airflow.

Three convenient patterns for auto-swing operation

The turbofan was designed using advanced aviation technology to reduce draft resistance inside the unit, achieving quiet sound level of 33/29 dB (A) to 35/30 dB (A).

Quiet operation

Allows fresh air to be circulated using only the fan for improved room ventilation. This is useful in buildings where ventilation fans cannot be installed.

Optional fresh air intake kitA chamber can be connected to the air conditioner to provide additional airflow for crowded spaces or areas sensitive to outside temperatures.

Optional branch duct chamber

Design flexibility

All models feature a decoration panel with the same compact size and simple design for easier planning of lighting systems and harmonising of interior décor.

Compact decoration panel

Installation flexibility

These models have the power to provide a comfortable airflow even with a ceiling height of up to 3.8 m.

High-ceiling applications

The indoor units weigh only 24 kg and require an installation space with a height of just 245 mm.

Light and compact main units

A system provides lift for the drain pump of up to 750 mm from the ceiling. This is convenient for multi-storied buildings, which have a large amount of other piping and wiring inside the ceiling.

High-lift drain pump

Standard

Draft prevention

Soiling prevention

950 mm

950

mm

Min. 245 mm

Same for all models

750 mm

Max. 3.8 m

Intake ductFresh air intake kit (Outdoor)

Hood

Air filterDischarge duct

Branch duct chamber

Discharge panel

Note: The intake duct, hood, air filter, insect screen, fireproof damper, etc. should be obtained locally if required.

Note: The discharge duct, discharge panel, etc. should be obtained locally if required.

Decoration panel is optional

Diffuser

3-dimensional blade

FCQ35

33/29 dB(A)

FCQ50

33/29 dB(A)

FCQ60

35/30 dB(A)

FCQ71

35/30 dB(A)

(H/L)

Page 14: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

13

Ceiling-mounted cassette (compact Ceiling-mounted cassette (compact

Coolingonly

Heatpump

2.5 kW class

FFQ25BV1B

FFQ25BV1B

3.5 kW class

FFQ35BV1B

FFQ35BV1B

5.0 kW class

FFQ50BV1B

FFQ50BV1B

6.0 kW class

FFQ60BV1B

FFQ60BV1B

The ideal air conditioner for installation inside narrow false ceilings—with only the smooth and simply finished decoration panel visible after installation. The compact dimensions are suitable even for the light commercial market as well as for the living rooms with false ceilings found in multi-storey apartment blocks.

Compact dimensions suitable for the light commercial market

600 x 600

Option

Option

Signal receiver unitNote: Remote controller cables not included. Cables should beobtained locally.

Note: Wireless remote controllers and signal receiver units are sold as a set.

Page 15: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

14

multi flow) typemulti flow) type

Design flexibility

Designed to fit 600 mm wide ceiling grids Quiet sound level of only 24.5 dB (A)

Multi-flow system offers a selection of air discharge patterns that suit all areas.

Comfort and quietness

Even for modules other than 600 x 600, no inspection opening is required. Maintenance can be performed after simply removing the grille, because the switchbox is built into the unit.

T-bar grid does not need to be cut.

575 mm

575 mm

700 mm

700 mm

286 mm

Compact

decoration panel

T-bar

600 mm600 mm

Ceiling panel

Spiral hub cover

At low fan speeds, the 2.5 kW model produces sound of only 24.5 dB (A), and even the 6.0 kW model as low as 32 dB (A). This is due to a new spiral hub cover that reduces internal airflow resistance.

4-way flow

1 pattern

3-way flow

4 patterns

2-way flow

1 pattern

" " denotes piping direction. " " denotes sealing member for air discharge outlet (option).

Note: For 3-way or 2-way flow installation, the sealing member for air discharge outlet (option) must be used to close off the unused outlet(s).

Low draft performance is designed for your comfort.

Horizontal Flow0° 0°

Less draught

FFQ25

29.5/24.5 dB(A)

FFQ35

32/25 dB(A)

FFQ50

36/27 dB(A)

FFQ60

41/32 dB(A)

(H/L)

Settable to 5 different levels between 0° and 35°

Settable to 5 different levels between 0° and 60°

Settable to 5 different levels between 25° and 60°

Auto-swing between 0° and 35°

Auto-swing between 0° and 60°

Auto-swing between 25° and 60°

Draft prevention setting(Set on site)

(Set on site)

Standard setting

Setting to prevent soiling of ceiling

Conditioned air is distributed evenly by Auto-swing operation.

Adjustable airflow angle to suit all room conditions.

AUTO-SWING

0° 0°

25°

60° 60°

35°

25°

60°

35°

60°

5 direction

Note: Angles shown above are provided as a guide. They may differ depending on the installation site.

Comfortable across all areas

Page 16: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

15

Ceiling-mounted built-in typeCeiling-mounted built-in type

Coolingonly

Heatpump

6.0 kW class

FBQ60BV1

FBQ60BV1

7.1 kW class

FBQ71BV1

FBQ71BV1

This ceiling-mounted built-in air conditioner is highly flexible in installation. The visible part is small, with a simple finish that blends in with any type of room.

Flexible air discharge unit to fit various forms of space

Note: Remote controller cables not included. Cables should beobtained locally.

Option

Page 17: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

16

Installation flexibility

The indoor unit can be installed in rooms with as little as 350 mm between the drop ceiling and ceiling slab. It also works with both flexible and ordinary ducts.

Meets diverse installation needs

Drainage pipes can be run as high as 250 mm above the drain outlet.

Provided with drain water lift-up mechanism as standard equipment Available in two types: 65% and 90%

colourimetry. This filter easily meets dust collection efficiency regulations specified in building codes.

High-efficiency filter (option)To cope with the challenges of L-shaped or U-shaped spaces, it is possible to install the air discharge unit away from the main unit. This extends the possibilities for coping with human gathering patterns or sun lighting. At the same time, different types of architectural space can be kept comfortable.

Flexibly adapts to room interiors

Comfort and quietness

Quiet operation

L-shaped room U-shaped room Long room

250 mm

Comfort and quietnessFBQ60

41/35 dB(A)

FBQ71

41/35 dB(A)

(H/L)

Canvas bellows and air intake panel

Flexible duct(dia. 200 mm)

Flexible duct(dia. 150 mm)

Branch duct

Air discharge grille

Air discharge chamber

Air discharge opening adaptor

Decoration panel

1

3

7

1

1

1

2

3

3

4

8

9

7911

5

10

46

5

Air conditioner

Long-life filter

Air blow Air intake

425 mm or more46

5

2 2Air conditioner

Long-life filterAir blowAir intake

350 mm or more

Standard installation examples

With high-efficiency filter Ceiling return

In crawl space With canvas bellows and air intake panel (sold separately)

45 mm

46

5

Air conditioner

Long-life filter

Air blow

Air intake450 mm or more

8

Air conditioner Ordinary duct(procured locally)

Ordinary duct(procured locally)

Air blow Air intake

460 mm or more

8

Air intake

Ceiling return with high-efficiency filter With ordinary ducts

46

5

Air conditioner

Air blow Air intake

540 mm or more13

946

5

Air conditioner

Air blow

540 mm or more

Options

Air discharge opening adaptorDecoration panel

Canvas bellows and air intake panelFlexible ductAir discharge grille

Air discharge opening flangeRear intake blocking pad

6

7

8

Air discharge chamber

Inspection panelHigh-performance filter

11

12

13 Low-draft filter chamberBranch ductRear intake filter chamber1011

22

2

Page 18: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

17

Ceiling-suspended typeCeiling-suspended type

This ceiling-suspended type air conditioner features a slim body with a quiet and wide airflow.

Slim body with quiet and wide airflow

Coolingonly

Heatpump

3.5 kW class

FHQ35BVV1B

FHQ35BVV1B

5.0 kW class

FHQ50BVV1B

FHQ50BVV1B

6.0 kW class

FHQ60BVV1B

FHQ60BVV1B

Option

Option

Signal receiver unitNote: Remote controller cables not included. Cables should beobtained locally.

Note: Wireless remote controllers and signal receiver units are sold as a set.

Page 19: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

18

Comfort and quietness

Auto-swing for comfort in all directions.

Spreads comfortable air throughout the room

Easier to maintain

Two time settings (2500 hrs and 1250 hrs) are available to match the installation environment. Maintenance time warning is displayed on the remote controller (filter sign).

Long-life filter lasts about 1 year* Maintenance not required

Quiet operation has been emphasised even more on the exposed ceiling suspended type unit.

Quiet operation

Design and installation flexibility

Uniform height and depth. Narrower design for small-capacity models to meet tighter dimensional constraints.

Easier installation for greater freedom of design

Drain pipe connection can be done inside the unit. Refrigerant and drain pipe outlets are at the same opening.

Drain pump kit (option) can be easily incorporated

FHQ35

37/32 dB(A)

FHQ50

38/33 dB(A)

FHQ60

39/33 dB(A)

(H/L)

Wide air discharge openings produce a spreading 100° airflow

Installable on ceilings 3.5 m high

Uses quiet stream fan and other quiet technologies.

100°

Sound damper

Turbulent flow is produced

Straightening vane

Quiet stream fan

195

960 1,160

680

(mm)

Height

Indoor unit

Width

Depth

FHQ35 FHQ50 FHQ60

Drain pump kit (built inside main unit)

600 mm

Non-dew flap

* For dust concentration of 0.15 mg/m3

Absence of bristles minimises clinging dirt and simplifies cleaning.

Non-dew flap without bristles

It is easy to wipe dirt off the flat side and lower surfaces of the unit.

Easy-clean, flat surfaces

Page 20: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

19

Duct-connected typeDuct-connected type

Coolingonly

Heatpump

2.5 kW class

CDKS25EAVMA

CDXS25EAVMA

3.5 kW class

CDKS35EAVMA

CDXS35EAVMA

Coolingonly

Heatpump

2.5 kW class

CDKS25CVMA

FDXS25CVMA

3.5 kW class

CDKS35CVMA

FDXS35CVMA

5.0 kW class

CDKS50CVMA

FDXS50CVMA

6.0 kW class

CDKS60CVMA

FDXS60CVMA

The visible parts have a smooth and sophisticated finish that blends with any type of interior décor. A wireless remote controller is a standard feature, offering you great convenience.

Slim and smooth design suits your shallow ceiling

700 mm width type 900/1,100 mm width typeOption

Page 21: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

20

Notes: 1. To prevent an increase in operation noise, avoid installing the air suction grille directly below the suction chamber. 2. Grilles, piping connections, ducts, and installation parts should be obtained locally. Duct-connected types do not have drain-up pumps. 3. The signal receiver unit must be located near the air suction inlet, because the unit includes a sensor that detects room temperature.

Suction grille (KDGF19A45)

Option

Signals from the wireless remote controllerare transmitted to the signal receiver.

240 mm

Installation flexibility

Models in the CDKS-EA and CDXS-EA series are only 700 mm in width and 21 kg in weight, so are easily installed in limited spaces. Just 200 mm in height, all models can be installed in rooms with as little as 240 mm depth between the drop ceiling and ceiling slab, making them ideal for even shallow ceilings.

CDKS25C(F)DXS25

35/31/29 dB(A)

CDKS35C(F)DXS35

35/31/29 dB(A)

CDKS50FDXS50

37/33/31 dB(A)

CDKS60FDXS60

38/34/32 dB(A)

(H/L/SL)

Slim and compact design

Home Leave Operation prevents large rises or falls in the indoor temperature by continuing operation* while you are sleeping or out of your home. This means that an air-conditioned welcome awaits when you wake or return. It also means that the indoor temperature can quickly return to your favourite comfort setting.* Home Leave Operation can be selected for any temperature from 18 to 32 C for cooling operation and 10 to 30 C for heating operation.

Home Leave Operation

Comfort and quietness

Quiet operation sound level of only 29 dB (A) is achieved.

Quiet operation

Dimensions (H x W x D)WeightAirflow rate (H)External static pressure

200 x 700 x 620 mm21 kg

8.7 m3/min30 Pa

200 x 900 x 620 mm25 kg

40 Pa

CDKS25EACDXS25EA

CDKS35EACDXS35EA

CDKS25CFDXS25C

CDKS35CFDXS35C

9.5 m3/min 10 m3/min

200 mmOnly 700 mm

Morecompact

CDKS-EACDXS-EA

900 mm 200 mm

CDKS-CFDXS-C

* Width for the CDKS60C and FDXS60C models is 1,100 mm.

* Locally obtained parts

AIRAir suction grille*

Suction duct*

Signal receiver

Air discharge duct*

Suspension bolt*

Air discharge grille*

Signal receiver wireLength = 1,900 mm

Chamber

AIR

Air filter

Page 22: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

21

Coolingonly

Heatpump

Coolingonly

Heatpump

Wall-mounted typeWall-mounted type

GOOD DESIGNAWARD 2004

IN JAPAN

Stylish flat panel harmonises with your interior décor

The simple and sophisticated flat panel design coordinates smoothly with any type of interior décor. Its refined design and functions provide you with the comfortable living environment you would like.

2.5 kW class

FTKS25GVMA

FTXS25GVMA

2.0 kW class

FTKS20DVMA

FTXS20DVMA

3.5 kW class

FTKS35GVMA

FTXS35GVMA

5.0 kW class

FTKS50JVMA

FTXS50JVMA

6.0 kW class

FTKS60JVMA

FTXS60JVMA

7.1 kW class

FTKS71JVMA

FTXS71JVMAOption

Option

NewDesign

GOOD DESIGNAWARD

IN JAPAN

The "Good Design Award" is Japan's only synthetic design evaluation/recommendation system and is sponsored by

the Japan Industrial Design Promotion Organization.

Page 23: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

22

Versatile remote control

The remote controller with a backlit liquid crystal display and luminescent control buttons also features a built-in Weekly Timer that can be programmed to suit your personal lifestyle, with up to four actions per day for each day of the week.This controller not only allows you to programme on and off times, but also the desired temperature during those times. Furthermore, the ‘copy’ function enables any daily programme to be replicated on any other day or days as required. Correct programming of the unit may also result in considerable energy savings.* This function is available for FTK(X)S50/60/71.

Comfort and quietness

Wall-mounted type indoor units achieve quiet sound level of 22 dB (A).

Quiet operation

FTKS20/25

37/25/22 dB(A)

FTKS35

38/26/23 dB(A)

FTKS50

44/35/32 dB(A)

FTKS60

45/36/33 dB(A)

FTKS71

46/37/34 dB(A)

(H/L/SL)

Econo ModeEcono Mode reduces the maximum running current and the maximum power consumption of the outdoor unit to the rated values. This is useful when using multiple air conditioners and other electrical devices at the same time.

From start-up until set temperature is reached

Maximum

Rated

• This diagram is a representation for illustrative purposes only.• Maximum capacity decreases during Econo Mode, requiring more time to reach the set temperature.

Maximum during normal operation

Running current and power consumption

Time

Normal operation

Econo Mode

Maximum during Econo Mode

Clean air

Titanium Apatite Photocatalytic Air-Purifying Filter

Titanium apatite is a photocatalytic material with high adsorption power. Besides mould and odours, titanium apatite also effectively adsorbs and decomposes bacteria and viruses across its entire surface. The photocatalyst is activated simply by exposure to light.

These filters are not medical devices. Benefits such as the adsorption and decomposition of bacteria and viruses are only effective for substances that are collected on and in direct contact with the Titanium Apatite Photocatalytic Air-Purifying Filter.

Bacteria Removal TestTesting method: dropping methodResult certificate: No. 012553-1 and 012553-2Testing organisation: Japan Spinners Inspecting Foundation

Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement, it adjusts the temperature by 2 C for energy savings of up to 20% for cooling operation and 30% for heating operation.

Intelligent Eye

When you are in the room When you go out

Comfort Airflow ModeComfort Airflow Mode prevents uncomfortable drafts from blowing directly on to your body. With this function, when you press the COMFORT button during cooling operation, the flap moves upward to prevent direct cold drafts. During heating operation, it also moves downward to prevent direct drafts and deliver warm air to the floor.* This function is available for FTK(X)S50/60/71.

Cooling operation Heating operation

A luminescent material is used for the buttons on the surface.

The LCD panel with backlight Weekly Timer

operation button

Titanium Apatite Photocatalytic Air-purifying Filter

Air filterCatches dust

Page 24: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

23

Floor-standing typeFloor-standing type

Heatpump

3.5 kW class

FVXS35GV1A

2.5 kW class

FVXS25GV1A

5.0 kW class

FVXS50GV1A

A space-saving air-conditioner of simple and neat appearance suitable for installation virtually anywhere you like in a room. It realises airflow to the furthest corners with efficient Vertical Auto-Swing and Wide-Angle Louvres.

Dual discharges to distribute warm air across the whole floor

Page 25: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

24

Dual air discharge for enhanced comfort

Clean air

Stylish and compact flat panel

Versatile remote control

Daikin’s inverter floor standing split systems are especially effective in heating. The unit features dual air outlets that diffuse warm, cosy air at low floor level—where you need it most in winter. This, combined with the vertical auto swing louvres on the top air outlet, provides uniform distribution of heated air in the room.Once winter is over, the lower air outlet can be shut off, leaving the top air diffuser to stream cool refreshing air upwards, allowing you to enjoy a cool, comfortable summer.

Double airflow keeps feet warm during heating operation.

Uses a Titanium Apatite Photocatalytic Air-Purifying Filter. Titanium apatite is a photocatalytic material with high adsorption power. It effectively adsorbs and removes bacteria and viruses along with mould and odours.These filters are not medical devices. Benefits such as the adsorption and decomposition of bacteria and viruses are only effective for substances that are collected on and in direct contact with the Titanium Apatite Photocatalytic Air-Purifying Filter.

Bacteria Removal TestTesting method: dropping methodResult certificate: No. 012553-1 and 012553-2Testing organisation: Japan Spinners Inspecting Foundation

Internal structure

3D air filter catches dust.Titanium apatite photocatalytic air-purifying filter

The clever construction of the elegant flat panel unit allows the flexibility of fully exposed installation against a wall or semi-recessed installation in spaces such as in a mantelpiece.

Easier cleaningThe flat panel design makes cleaning the front face of the unit a breeze. Surface dust can be simply wiped away with a soft cloth. Furthermore, the unit can be installed off the floor to allow for cleaning of the floor space under the unit.

The remote controller with a backlit liquid crystal display and luminescent control buttons also features a built-in Weekly Timer that can be programmed to suit your personal lifestyle, with up to four actions per day for each day of the week.This controller not only allows you to programme on and off times, but also the desired temperature during those times. Furthermore, the ‘copy’ function enables any daily programme to be replicated on any other day or days as required. Correct programming of the unit may also result in considerable energy savings.

Weekly Timeroperation button

Wiping clean the flat panel is a breeze. Easily clean beneath the unit.

Page 26: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

25

Floor/ceiling-suspended dual typeFloor/ceiling-suspended dual type

Heatpump

2.5 kW class

FLXS25BVMA

3.5 kW class

FLXS35GVMA

5.0 kW class

FLXS50GVMA

6.0 kW class

FLXS60GVMA

The floor/ceiling-suspended dual type’s slim, rounded design allows both ceiling-suspended and floor-level installation. Ceiling-suspended installation frees up wall and floor space, while floor-level installation is possible without loss of warm air.

Floor/ceiling dual use maximises free space

Two-way installation

Ceiling-suspended installation Floor-level installation

Page 27: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

26

Comfort and quietness

Vertical Auto-Swing and Wide-Angle Louvres realise that comfortable airflow spreads throughout a large room. With these functions, the whole room can be evenly air-conditioned from either a floor-level or ceiling-suspended installation. The louvres can be adjusted by hand.

Comfortable airflowThe curved design of the indoor unit merges smoothly with the wall or floor to enhance the décor of any room.

Slim and attractive indoor unit

The indoor unit is only 490 mm in depth and weighs a featherlight 16 kg, which means it can be quickly and efficiently installed by one person.

Compact and lightweight indoor unit

The floor/ceiling-suspended dual type indoor units achieve quiet sound level of 28 dB (A).

Quiet operation

FLXS25

37/31/28 dB(A)

FLXS35

38/32/29 dB(A)

FLXS50

47/39/36 dB(A)

FLXS60

48/41/39 dB(A)

(H/L/SL)

During cooling operation

The Vertical Auto-Swing and Wide-Angle Louvres direct warm/cool air to every corner of your room.

Clean air

Design and installation flexibility

The Photocatalytic Deodorising Filter is able to decompose odours and even removes bacteria and viruses. This filter can be used indefinitely if regular maintenance is carried out.Bacteria Removal TestTesting method: dropping methodResult certificate: No. 298081197-003Virus Removal TestTesting method: washout methodResult certificate: No. 298081197-004Testing organisation: Japan Food Research Laboratories

Photocatalytic Deodorising Filter

The filter removes bacteria and viruses, and impurities such as dust, pollen and cigarette smoke from the air. Its removal rate for bacteria and viruses has been measured and verified by the Japan Food Research Laboratories.Bacteria Removal TestingMeasurement method: dropping method. Test result certificate number 298051308-001Virus Removal TestingMeasurement method: washout method. Test result certificate number 298051308-002

These filters are not medical devices. Benefits such as the adsorption and decomposition of bacteria and viruses are only effective for substances that are collected on and in direct contact with the Photocatalytic Deodorising Filter or Air-Purifying Filter.

Air-Purifying Filter

1,050 mm200 mm

490

mm

Page 28: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

27

Functions

Models

FCQ FFQ FBQ FHQ

Ceiling-mounted cassette type Ceiling-mounted built-in type Ceiling-suspended type

Function listFunction list

Power-airflow dual flaps

Wide-angle louvres

Vertical auto-swing (up and down)

Horizontal auto-swing (left and right)

3-D airflow

Comfort airflow mode

Indoor unit quiet operation

Night quiet mode

Intelligent eye

Automatic operation (Heat pump only)

Programme dry function

Auto fan speed

Hot-start function (Heat pump only)

Quick warming function (Heat pump only)

Automatic defrosting (Heat pump only)

Inverter powerful operation

Econo mode

Home leave operation

Indoor unit on/off switch

Signal reception indicator

Titanium apatite photocatalytic air-purifying filter

Photocatalytic deodorising filter

Air-purifying filter

Mould-proof air filter

Long-life air filter

High-efficiency filter kit (option)

Fresh air intake kit (option)

Mould-proof operation

Wipe-clean flat panel

Filter cleaning indicator

24-hour on/off timer

72-hour on/off timer

Weekly timer

Night set mode

Auto-restart after power failure

Self-diagnosis with digital display

Anticorrosion treatment of outdoor heat exchanger fins

High-ceiling application

Flexible voltage correspondence

Drain water lift-up mechanism

Ceiling soiling prevention

Comfortable airflow

Comfort control

Lifestyle convenience

Cleanliness

Timers

Worry free

Flexibility

Page 29: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

28

Indoor unit Outdoor unit

CDK(X)S/FDXS FTK(X)S20-35 FTK(X)S50-71 FVXS FLXS

Duct-connected type Wall-mounted type Floor-standing type Floor/ceiling-suspended dual type

NewDesign

NewNew

NewNew

NewNew

Page 30: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

29

Outdoor unit

Specifications

Outdoor unit

Model name

Power supply

Capacity (rated)

Total indoor unit capacity

Number of indoor units to be connected

Number of BP to be connected

Casing colour

Compressor

Airflow rate (H)

Refrigerant

Refrigerant oil

Sound level

Sound powerlevel

Dimensions (H x W x D)

Machine weight

Operating range

Number of wiring connections

Piping connections

Max. interunit

piping length

Necessity of additional charge

Max. height difference

Cooling

Heating

Type

Motor output

Cooling

Heating

Type

Charge

Model

Charge

Cooling

Heating

Cooling

Heating

Cooling

Heating

Liquid (flare)

Gas (brazing)

Drain

Total main piping and

branch piping

Total main piping

Total branch piping

Max. length for each room

kW

kW

kW

kg

dB (A)

dB (A)

mm

kg

CDB

CWB

mm

mm

mm

m

m

m

m

kg/m

m

m

Note: * Refrigerant charge is required. (Chargeless piping length 0 m) Formula for calculation charge: R (kg) R = Total length (m) of liquid pipe size at ø9.5 x 0.054 + Total length (m) of liquid piping size at ø6.4 x 0.022

RMXS112EV1A

11.2

12.5

5.5 to 14.5

6

2.5

52

54

67

69

115

60

RMXS140EV1A

14.0

16.0

7.0 to 18.2

8

3.0

1,767 (3,742)

53

55

68

70

-15 to 15.5

135

80

1 phase, 220-240 V, 50 Hz

Ivory white

Hermetically sealed scroll type

1,767 (3,742)

R-410A

4.0

DAPHNE FVC68D

1.5

1,345 x 900 x 320

125

- 5 to 46

ø9.5

ø19.1

ø18.0

RMXS160EV1A

15.5

17.5

8.0 to 20.8

9

3.5

54

56

69

71

145

90

Between indoor or BP unit and outdoor unit: 30

Between indoor and BP unit: 15

RMKS160EV1A

15.5

8.0 to 20.8

9

3.5

54

69

145

90

RMKS140EV1A

14.0

7.0 to 18.2

8

3.0

53

68

135

80

RMKS112EV1A

11.2

5.5 to 14.5

6

2.5

52

67

115

60

Cooling only Heat pump

55

15

Necessary*

3

3 for power supply (including earth wiring), 2 for interunit wiring (outdoor unit-BP)

/s(cfm)

Measurement conditions1. Cooling operation data is based on the following conditions: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB.2. Heating operation data is based on the following conditions: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB.3. Sound levels are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

Page 31: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

30

Ceiling-mounted cassette (compact multi flow) type

Indoor unit

Model name

Power supply

Airflow rate (H)

Sound level*(H/L)

Sound powerlevel (H)

Fan speed

Temperature control

Unit dimensions (H x W x D)

Machine weight

Piping connections

Heat insulation

Cooling

Heating

Cooling

Heating

Cooling

Heating

Liquid (flare)

Gas (flare)

Drain

dB (A)

dB (A)

mm

kg

mm

mm

mm

Model

Colour

Dimensions (H x W x D)

Weight

mm

kg

Panel (option) 55 x 700 x 700

FFQ35BV1B

167 (353)

32/25

49

FFQ50BV1B

200 (424)

36/27

53

FFQ60BV1B

250 (530)

41/32

58

FFQ25BV1B

150 (318)

29.5/24.5

46.5

FFQ35BV1B

167 (353)

167 (353)

32/25

32/25

49

49

FFQ50BV1B

200 (424)

200 (424)

FFQ60BV1B

250 (530)

250 (530)

FFQ25BV1B

150 (318)

150 (318)

29.5/24.5

29.5/24.5

46.5

46.5

White

36/27

36/27

53

53

41/32

41/32

58

58

286 x 575 x 575

17.5

ø6.4

VP20 (External Dia. 26/Internal Dia. 20)

ø12.7ø9.5

BYFQ60B8W1

2.7

Heat pumpCooling only

2 steps

Microcomputer control

Both liquid and gas pipes

/s(cfm)

1 phase, 220-240 V, 50 Hz

ø9.5 ø12.7

600 x 600

Cooling

Heating

Cooling

Heating

Ceiling-mounted cassette (multi flow) type

Model name

Power supply

Airflow rate (H)

Sound level*

(H/L)

Sound power

level (H)

Fan speed

Temperature control

Unit dimensions (H x W x D)

Machine weight

Piping connections

Heat insulation

Liquid (flare)

Gas (flare)

Drain

mm

kg

FCQ50BVE

250 (530)

FCQ60BVE FCQ71BVE

dB (A)

dB (A)

mm

kg

mm

mm

mm

Note: * For 220 V operation.

33/29

ø12.7

FCQ35BVE

233 (494)

ø9.5

ø6.4 ø6.4ø9.5

ø15.9

ø9.5

ø15.9

35/30

Colour

Dimensions (H x W x D)

Weight

Panel (option)

Model

White

40 x 950 x 950

5

FCQ50BVE

250 (530)

250 (530)

FCQ60BVE FCQ71BVEFCQ35BVE

ø9.5

33/29 35/30

33/29 35/30

48

50

48 50

48 50

317 (671)

317 (671)

ø12.7

Cooling only Heat pump

Both liquid and gas pipes

BYC125K-W1

I.D ø25 x O.D ø32

2 steps

Microcomputer control

1 phase, 220-240 V/220 V, 50/60 Hz

230 x 840 x 840

24

/s(cfm)

Cooling

Heating

233 (494)

233 (494)

317 (671)

Note: * Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.

Page 32: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

31

Ceiling-suspended type

Model name

Power supply

Front panel colour

Airflow rate (H)

Sound level (H/L)

Sound powerlevel (H/L)

Fan speed

Temperature control

Dimensions (H x W x D)

Machine weight

Piping connections

Heat insulation

Cooling

Heating

Cooling

Heating

Cooling

Heating

Liquid (flare)

Gas (flare)

Drain

dB (A)

dB (A)

mm

kg

mm

mm

mm

1 phase, 220-240 V, 50 Hz

White

2 steps

Microcomputer control

ø6.4

VP 20 (External Dia. 26/Internal Dia. 20)

Both liquid and gas pipes

FHQ60BVV1B

283 (600)

39/33

55/49

195 x 1,160 x 680

27

FHQ50BVV1B

38/33

54/49

25

FHQ35BVV1B

37/32

53/48

24

ø9.5

FHQ60BVV1B

283 (600)

267 (564)

39/33

39/33

55/49

55/49

195 x 1,160 x 680

27

FHQ50BVV1B

38/33

38/33

54/49

54/49

25

FHQ35BVV1B

37/32

37/32

53/48

53/48

24

ø9.5

195 x 960 x 680

217 (458) 217 (458)

217 (458)

195 x 960 x 680

ø12.7 ø12.7

Cooling only Heat pump

/s(cfm)

Ceiling-mounted built-in type

Model name

Power supply

Airflow rate (H)

Sound level*(H/L)

Sound powerlevel (H)

Fan speed

Temperature control

Dimensions (H x W x D)

Machine weight

Piping connections

Heat insulation

Cooling

Heating

Cooling

Heating

Cooling

Heating

Liquid (flare)

Gas (flare)

Drain

dB (A)

dB (A)

mm

kg

mm

mm

mm

FBQ71BV1

317 (670)

ø9.5

ø15.9

1 phase, 220-240 V, 50 Hz

41/35

60

2 steps

Microcomputer control

300 x 1,000 x 800

41

I.D ø25 x O.D ø32

Both liquid and gas pipes

FBQ60BV1

283 (600)

ø6.4

ø12.7

FBQ71BV1

317 (670)

317 (670)

ø9.5

ø15.9

FBQ60BV1

283 (600)

283 (600)

ø6.4

ø12.7

Cooling only Heat pump

Note: * For 220 V operation.

41/35

60

mm

kg

Colour

Dimensions (H x W x D)

Weight

Panel (option)

Model BYBS71DJW1

White

55 x 1,100 x 500

4.5

/s(cfm)

Page 33: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

32

Model name

Power supply

Airflow rate (H)

Sound level*

(H/L/SL)

Sound power

level (H)

Fan speed

Temperature control

Dimensions (H x W x D)

Machine weight

Piping connections

Heat insulation

External static pressure

Cooling

Heating

Cooling

Heating

Cooling

Heating

Liquid (flare)

Gas (flare)

Drain

dB (A)

dB (A)

mm

kg

mm

mm

mm

Pa

Duct-connected type <700 mm width>

1 phase, 220-240 V/220-230 V, 50/60 Hz

145 (307)

35/31/29

53

5 steps, quiet and automatic

Microcomputer control

200 x 700 x 620

21

ø6.4

ø9.5

VP 20 (External Dia. 26/Internal Dia. 20)

Both liquid and gas pipes

30

CDKS35EAVMA

145 (307)

35/31/29

53

CDKS25EAVMA CDXS35EAVMACDXS25EAVMA

Cooling only Heat pump

Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 30 Pa. Sound level values for bottom-suction operation can be obtained by adding 6 dB.

/s(cfm)

Model name

Power supply

Airflow rate (H)

Sound level*

(H/L/SL)

Sound power

level (H)

Fan speed

Temperature control

Dimensions (H x W x D)

Machine weight

Piping connections

Heat insulation

External static pressure

Cooling

Heating

Cooling

Heating

Cooling

Heating

Liquid (flare)

Gas (flare)

Drain

dB (A)

dB (A)

mm

kg

mm

mm

mm

Pa

Duct-connected type <900/1,100 mm width>

1 phase, 220-240 V/220-230 V, 50/60 Hz

5 steps, quiet and automatic

Microcomputer control

ø6.4

VP 20 (External Dia. 26/Internal Dia. 20)

Both liquid and gas pipes

40

CDKS50CVMA

200 (424)

37/33/31

55

27

CDKS60CVMA

267 (565)

38/34/32

56

30

35/31/29

53

25

ø9.5

35/31/29

35/31/29

53

53

25

ø9.5

CDKS35CVMA

167 (353)

CDKS25CVMA

158 (335)

FDXS50CVMA

200 (424)

200 (424)

37/33/31

37/33/31

55

55

27

FDXS60CVMA

267 (565)

267 (565)

38/34/32

38/34/32

56

56

30

FDXS35CVMA

167 (353)

167 (353)

FDXS25CVMA

158 (335)

158 (335)

Cooling only Heat pump

200 x 900 x 620 200 x 900 x 620200 x 1,100 x 620 200 x 1,100 x 620

ø12.7 ø12.7

Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 40 Pa. Sound level values for bottom-suction operation can be obtained by adding 5 dB.

/s(cfm)

Page 34: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

33

Wall-mounted type

Model name

Power supply

Front panel colour

Airflow rate (H)

Sound level

(H/L/SL)

Sound power

level (H)

Fan speed

Temperature control

Dimensions (H x W x D)

Machine weight

Piping connections

Heat insulation

Cooling

Heating

Cooling

Heating

Cooling

Heating

Liquid (flare)

Gas (flare)

Drain

dB (A)

dB (A)

mm

kg

mm

mm

mm

Heat pumpCooling only

FTKS25GVMAFTKS20DVMA

White

5 steps, quiet and automatic

Microcomputer control

283 x 800 x 195

9

ø6.4

ø9.5

ø18.0

Both liquid and gas pipes

FTKS35GVMA

148 (314)

38/26/23

54

1 phase, 220-240 V/220-230 V, 50/60 Hz

FTXS25GVMAFTXS20DVMA FTXS35GVMA

148 (314)

162 (342)

38/26/23

38/29/26

54

54

/s(cfm)

Wall-mounted type

Model name

Power supply

Front panel colour

Airflow rate (H)

Sound level

(H/L/SL)

Sound power

level (H)

Fan speed

Temperature control

Dimensions (H x W x D)

Machine weight

Piping connections

Heat insulation

Cooling

Heating

Cooling

Heating

Cooling

Heating

Liquid (flare)

Gas (flare)

Drain

dB (A)

dB (A)

mm

kg

mm

mm

mm

Heat pumpCooling only

White

5 steps, quiet and automatic

Microcomputer control

290 x 1,050 x 250

12

ø6.4

ø18.0

Both liquid and gas pipes

1 phase, 220-240 V/220-230 V, 50/60 Hz

FTXS50JVMA

245 (519)

270 (572)

44/35/32

42/33/30

60

58

FTXS60JVMA

270 (572)

290 (614)

45/36/33

44/35/32

61

60

FTXS71JVMA

290 (614)

358 (759)

46/37/34

46/37/34

62

62

ø15.9

FTKS50JVMA

245 (519)

44/35/32

60

FTKS60JVMA

270 (572)

45/36/33

61

FTKS71JVMA

290 (614)

46/37/34

62

ø15.9 ø12.7ø12.7

/s

(cfm)

145 (307)

37/25/22

53

145 (307)

157 (332)

37/25/22

37/28/25

53

53

Page 35: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

34

Model name

Power supply

Front panel colour

Airflow rate (H)

Sound level

(H/L/SL)

Sound power

level (H)

Fan speed

Temperature control

Dimensions (H x W x D)

Machine weight

Piping connections

Heat insulation

Cooling

Heating

Cooling

Heating

Cooling

Heating

Liquid (flare)

Gas (flare)

Drain

dB (A)

dB (A)

mm

kg

mm

mm

mm

Floor/Ceiling-suspended dual type

Heat pump

FLXS50GVMA

190 (402)

202 (427)

47/39/36

46/35/33

63

62

FLXS60GVMA

200 (424)

213 (452)

48/41/39

47/37/34

64

63

FLXS35GVMA

143 (304)

163 (346)

38/32/29

39/33/30

54

55

FLXS25BVMA

126 (268)

153 (325)

37/31/28

37/31/29

53

53

Almond white

5 steps, quiet and automatic

Microcomputer control

490 x 1,050 x 200

ø6.4

ø18.0

Both liquid and gas pipes

1 phase, 220-240 V/220-230 V, 50/60 Hz

16 17

ø12.7ø9.5

/s

(cfm)

Floor-standing type

Model name

Power supply

Front panel colour

Airflow rate (H)

Sound level

(H/L/SL)

Sound power

level (H)

Fan speed

Temperature control

Unit dimensions (H x W x D)

Machine weight

Piping connections

Heat insulation

Cooling

Heating

Cooling

Heating

Cooling

Heating

Liquid (flare)

Gas (flare)

Drain

dB (A)

dB (A)

mm

kg

mm

mm

mm

Heat pump

FVXS35GV1A

142 (300)

157 (332)

39/27/24

39/27/24

55

55

FVXS50GV1A

178 (378)

197 (417)

44/36/32

45/36/32

56

57

ø12.7

White

5 steps, quiet and automatic

Microcomputer control

600 x 700 x 210

14

ø6.4

ø20.0

Both liquid and gas pipes

1 phase, 220-240 V, 50 Hz

/s(cfm)

FVXS25GV1A

137 (290)

147 (311)

38/26/23

38/26/23

54

54

ø9.5

Page 36: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

35

Model name

Power supply

Power consumption

Running current

Dimensions (H x W x D)

Machine weight

Number of wiring connections

Piping connections

(Brazing)

Heat insulation

Connectable indoor units

Min. rated capacity of

connectable indoor units

Max. rated capacity of

connectable indoor units

Liquid

Gas

Main

Branch

Main

Branch

mm

kg

mm

mm

mm

mm

W

A

kW

kW

2 ports (connectable to 1-2 indoor units)

BPMKS967A2

7.5

ø6.4 x 2

ø15.9 x 2

3 ports (connectable to 1-3 indoor units)

BPMKS967A3

8

ø6.4 x 3

ø15.9 x 3

1 phase, 220-240 V/220-230 V, 50/60 Hz

10

0.05

180 x 294 (+356*) x 350

ø9.5 x 1

ø19.1 x 1

Both liquid and gas pipes

2.0 kW class to 7.1 kW class

2.0

BP unit

3 ports 2 ports

3 for power supply (including earth wiring), 2 for interunit wiring (outdoor unit-BP, BP-BP), 4 for interunit wiring (BP-indoor unit)

Note: * Total auxiliary piping length.

20.8 14.2

Page 37: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

36

Ceiling-mounted cassette (compact multi flow) type

Decoration panel

Remote controller

Adaptor for wiring*2

Wiring adaptor for electrical appendices*2

Installation box for adaptor PCB

Remote sensor (for indoor temperature)

Replacement long-life filter

Fresh air intake kit

Sealing member for air discharge outlet

Panel spacer

BYFQ60B8W1

BRC1C61

KRP1BA57

KRP4AA53

KRP1BA101

KRCS01-1B

KAFQ441B60

KDDQ44X60

KDBHQ44B60

KDBQ44B60A

1

2

3

4

5

6

7

8

9

10

FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1BItemNo.

Notes: *1. Wiring for wired remote controller should be obtained locally.*2. Installation box for adaptor PCB (KRP1BA101) is necessary.

Direct installation type

Wired type*1

Wireless typeHeat pump use

Cooling only use

BRC7E530W

BRC7E531W

Outdoor unit

Ceiling-mounted cassette (multi flow) type

Indoor unit

1

2

Central drain plug

Air direction adjustment grille

KKPJ5F180

KPW945A4

1

2

3

4

5

6

7

8

9

10

11

12

Decoration panel

Panel spacer

Chamber typeWithout T-shaped pipe and fan*1

Fresh air intake kit With T-shaped pipe, without fan*2

Direct installation type*3

High-efficiency filter(Colourimetric method 65%)

(Colourimetric method 90%)

Replacement high-efficiency filter(Colourimetric method 65%)

(Colourimetric method 90%)

High-efficiency filter chamber

Longlife filter

Branch duct chamber

Wired type

Remote controllerWireless type

Heat pump use

Cooling only use

Group control adaptor*4

Wiring adaptor for electrical appendices*4

Installation box for adaptor PCB

BYC125K-W1

KDBP55H160WA

KDDP55D160

KDDP55D160K

KDDJ55X160

KAFP556D80

KAFP557D80

KAFP552H80

KAFP553H80

KDDF55DA160

KAF551KA160

KDJ55K80

BRC1C61

BRC7C612W

BRC7C613W

KRP4A53

KRP1B57

KRP1B98

Notes:*1. With a suction chamber. Fresh air intake is from 2 holes on the sides of the connection chamber. (This method should be selected if a wireless remote controller is used.)*2. Without a suction chamber. Fresh air intake is from 2 holes on the connection chamber via a T-shaped pipe connection. (A wireless remote controller cannot be used in this case.)*3. Without a suction chamber. Fresh air intake is directly from a hole on the main unit.*4. Installation box for adaptor PCB (KRP1B98) is necessary.

Options

RMXS160EV1ARMXS140EV1ARMXS112EV1ARMKS160EV1ARMKS140EV1ARMKS112EV1A

FCQ35BVE FCQ50BVE FCQ60BVE FCQ71BVEItem No.

No. Item

Page 38: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

37

Note: * Installation box for adaptor PCB (KRP1CA93) is necessary.

Ceiling-mounted built-in type

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

FBQ60BV1 FBQ71BV1ItemNo.

Decoration panel

Service access panel

High-efficiency filter

Replacement long-life filter

Filter chamber for bottom suction

Filter chamber for rear suction

Canvas duct

Discharge grille

Discharge chamber

Branch duct

Flexible duct

Blind board

Adaptor for discharge

Flange for suction

Remote controller

Adaptor for wiring (Interlock for fresh air intake fan)

Group control adaptor

Wired type

Wireless typeHeat pump use

Cooling only use

BYBS71DJW1

KTBJ25L80W

KAFJ252L80

KAFJ253L80

KAFJ251K80

KAJ25L80D

KAJ25L80B

KSA-25KA80

K-DG5DW

K-DG9DW

K-DGC5D

K-DGC9D

K-DDV20A

KBBJ25K80

KDAJ25K71

KDJ2507K80

BRC1C61

KRP1B54

KRP4A51

K-FDS151C(1m)/K-FDS152C(2m)/K-FDS153C(3m)/K-FDS154C(4m)/K-FDS155C(5m)/K-FDS156C(6m)

K-FDS201C(1m)/K-FDS202C(2m)/K-FDS203C(3m)/K-FDS204C(4m)/K-FDS205C(5m)/K-FDS206C(6m)

(Colourimetric method 65%)

(Colourimetric method 90%)

Resin net

ø150

ø200

ø150

ø200

ø150 ø200

ø150

ø200

Wired type

Ceiling-suspended type

1

2

3

4

5

6

7

FHQ35BVV1B FHQ50BVV1B FHQ60BVV1BItemNo.

Replacement long-life filter

Drain up kit

L-type piping kit (For upward direction)

Remote controller

Adaptor for wiring

Wiring adaptor for electrical appendices*

Installation box for adaptor PCB

FDU50M60VE

BRC1C61

BRC7EA63W

BRC7EA66

KRP1BA54

KRP4AA52

KRP1CA93

KAFJ501DA80KAF501DA56

KHFP5MA63KHFP5MA35

Duct-connected type

1

2

3

4

5

6

7

Wired remote controller*1

Wired remote controller cord

5-room centralised controller*2

Wiring adaptor for time clock/remote controller*3

(Normal open pulse contact/normal open contact)

Wireless remote controller loss prevention chain

Suction grille

Insulation kit for high humidity

Length 3 m (shielded wire)

Length 8 m (shielded wire)

Notes:*1. 3 m (BRCW901A03) or 8 m (BRCW901A08) length wired remote controller cord is necessary.*2. A wiring adaptor (KRP413A1S) is also required for each indoor unit.*3. Time clock and other devices should be obtained locally.

BRC944B2

BRCW901A03

BRCW901A08

KRC72

KRP413A1S

KKF917A4

KDGF19A45

CDXS25EAVMA CDXS35EAVMA FDXS50CVMA FDXS60CVMA

CDKS25EAVMA CDKS35EAVMA CDKS50CVMA CDKS60CVMA

KDT25N63KDT25N50

FDXS25CVMA FDXS35CVMA

CDKS25CVMA CDKS35CVMA

KDT25N32

ItemNo.

Page 39: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

38

Wall-mounted type

1

2

3

4

5

6

Wired remote controller*1

Wired remote controller cord

5-room centralised controller*2

Wiring adaptor for time clock/remote controller*3

(Normal open pulse contact/normal open contact)

Titanium apatite photocatalytic air-purifying filter*4

Wireless remote controller loss prevention chain

BRC944B2

BRCW901A03

BRCW901A08

KRC72

KRP413A1S

Notes:*1. 3 m (BRCW901A03) or 8 m (BRCW901A08) length wired remote controller cord is necessary.*2. A wiring adaptor (KRP413A1S) is also required for each indoor unit.*3. Time clock and other devices should be obtained locally.*4. Filter is a standard accessory. It should be replaced approximately every 3 years.

FTXS20DVMA FTXS25GVMA FTXS35GVMA FTXS50JVMA FTXS71JVMA

FTKS20DVMA FTKS25GVMA FTKS35GVMA FTKS50JVMA FTKS71JVMA

FTXS60JVMA

FTKS60JVMAItemNo.

KAF970A46

KKF917A4 KKF910A4

BP unit

Control system

No.

1

Item

REFNET joint

BPMKS967A2 BPMKS967A3

KHRP26A22T

No.

1

2

3

4

Central remote controller*

Unified on/off controller*

Schedule timer*

Interface adaptor

(For DIII-NET use)

FTK(X)S-D/G/J, FVXS-F, FLXS-B, CDK(X)S-EA, C(F)DK(X)S-C

FCQ-B, FFQ-B, FBQ-B, FHQ-B

Model No.

DCS302CA61

DCS301BA61

DST301BA61

KRP928B2S

DTA112B51

Note:* An interface adaptor (KRP928B2S or DTA112B51) is also required for each indoor unit.

Note:A single BP unit does not require a REFNET joint. 2 BP units require only 1 REFNET joint, and 3 BP units require only 2 REFNET joints.

Item

Floor-standing type

5-room centralised controller*1

Wiring adaptor for time clock/remote controller*2

(Normal open pulse contact/normal open contact)

Titanium apatite photocatalytic air-purifying filter*3

Remote controller loss prevention chain

KRC72

KRP413A1S

KAF968A42

KKF910A4

1

2

3

4

FVXS35GV1A FVXS50GV1AItemNo. FVXS25GV1A

Notes:*1. A wiring adaptor (KRP413A1S) is also required for each indoor unit.*2. Time clock and other devices should be obtained locally.*3. The photocatalytic deodorising filter is a standard accessory. It can be reused indefinitely if it is exposed to direct sunlight once every 6 months. This accessory is only required if the original filter is damaged or lost, etc.*4. The air-purifying filter is a standard accessory. It should be replaced approximately once every 3 months. This accessory is required for the replacement of filters.

Notes:*1. A wiring adaptor (KRP413A1S) is also required for each indoor unit.*2. Time clock and other devices should be obtained locally.*3. Filter is a standard accessory. It should be replaced approximately every 3 years.

Floor/ceiling-suspended dual type

5-room centralised controller*1

Wiring adaptor for time clock/remote controller*2

(Normal open pulse contact/normal open contact)

Photocatalytic deodorising filter with frame*3

Photocatalytic deodorising filter without frame*3

Air-purifying filter with frame*4

Air-purifying filter without frame*4

Remote controller loss prevention chain

KRC72

KRP413A1S

KAZ917B41

KAZ917B42

KAF925B41

KAF925B42

KKF917A4

1

2

3

4

5

6

7

ItemNo. FLXS25BVMA FLXS35GVMA FLXS50GVMA FLXS60GVMA

Length 3 m (shielded wire)

Length 8 m (shielded wire)

Page 40: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

39

Selection Procedure Outdoor unit RMK(X)S160E

Number of indoor units

2 to 9 units

Total indoor unit capacity

8.0 to 20.8 kW

Indoor unitmodel name Rated capacity (kW)

FTK(X)S-D/G/J, FVXS-G, FLXS-B/G, CDK(X)S-EA, C(F)DK(X)S-C, FCQ-B, FFQ-B, FBQ-B, FHQ-B252.5

202.0

353.5

505.0

606.0

717.1

Capacity TablesCooling capacity

1.681.711.751.781.811.851.881.911.951.982.012.052.082.112.142.182.212.242.282.312.342.382.412.442.482.512.542.572.612.642.672.712.742.772.812.842.872.902.942.973.003.043.073.103.143.173.203.243.273.303.333.373.403.433.473.503.533.573.603.63

3.673.703.733.763.803.833.863.903.933.964.004.004.014.024.024.034.044.054.054.064.074.074.084.094.104.104.114.124.124.134.14

Total indoor unit capacity

(kW)

Cooling capacity

(kW)

Power consumption

(kW)

Total indoor unit capacity

(kW)

Cooling capacity

(kW)

Power consumption

(kW)5.55.65.75.85.96.06.16.26.36.46.56.66.76.86.97.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.9

10.010.110.210.310.410.510.610.710.810.911.011.111.211.311.4

11.511.611.711.811.912.012.112.212.312.412.512.612.712.812.913.013.113.213.313.413.513.613.713.813.914.014.114.214.314.414.5

5.65.75.85.96.06.16.26.36.46.56.66.76.86.97.07.17.27.37.47.57.67.77.87.98.08.18.28.38.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.411.511.6

11.711.811.912.012.112.212.312.412.512.612.712.712.812.812.812.812.812.912.912.912.912.913.013.013.013.013.013.013.113.113.1

1.801.841.871.911.951.982.022.062.102.132.172.212.252.282.322.362.402.432.472.512.542.582.622.662.692.732.772.812.842.882.922.962.993.033.073.103.143.183.223.253.293.333.373.403.443.483.523.553.593.633.673.703.743.783.813.853.893.933.964.00

4.044.084.114.154.194.234.264.304.344.374.414.454.494.524.564.604.644.674.714.754.794.794.804.804.814.824.824.834.844.844.854.864.864.874.884.884.894.904.904.914.914.924.934.934.944.954.954.964.974.974.984.994.99

Total indoor unit capacity

(kW)

Cooling capacity

(kW)

Power consumption

(kW)

Total indoor unit capacity

(kW)

Cooling capacity

(kW)

Power consumption

(kW)7.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.411.511.611.711.811.912.012.112.212.312.412.512.612.712.812.9

13.013.113.213.313.413.513.613.713.813.914.014.114.214.314.414.514.614.714.814.915.015.115.215.315.415.515.615.715.815.916.016.116.216.316.416.516.616.716.816.917.017.117.217.317.417.517.617.717.817.918.018.118.2

6.97.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.510.610.710.810.911.011.111.211.311.411.511.611.711.811.912.012.112.212.312.412.512.612.7

12.812.913.013.113.213.313.413.513.613.713.813.914.014.114.214.314.414.514.614.714.814.814.814.814.814.914.914.914.914.914.914.915.015.015.015.015.015.015.015.115.115.115.115.115.115.115.115.215.215.215.215.215.2

1.681.711.751.781.811.851.881.911.951.982.012.052.082.112.142.182.212.242.282.312.342.382.412.442.482.512.542.572.612.642.672.712.742.772.812.842.872.902.942.973.003.043.073.103.143.173.203.243.273.303.333.373.403.433.473.503.533.573.603.63

3.673.703.733.763.803.833.863.903.933.964.004.004.014.024.024.034.044.054.054.064.074.074.084.094.104.104.114.124.124.134.14

Total indoor unit capacity

(kW)

Cooling capacity

(kW)

Power consumption

(kW)

Total indoor unit capacity

(kW)

Cooling capacity

(kW)

Power consumption

(kW)5.55.65.75.85.96.06.16.26.36.46.56.66.76.86.97.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.9

10.010.110.210.310.410.510.610.710.810.911.011.111.211.311.4

11.511.611.711.811.912.012.112.212.312.412.512.612.712.812.913.013.113.213.313.413.513.613.713.813.914.014.114.214.314.414.5

5.65.75.85.96.06.16.26.36.46.56.66.76.86.97.07.17.27.37.47.57.67.77.87.98.08.18.28.38.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.411.511.6

11.711.811.912.012.112.212.312.412.512.612.712.712.812.812.812.812.812.912.912.912.912.913.013.013.013.013.013.013.113.113.1

RMK(X)S112EV1A

1.801.841.871.911.951.982.022.062.102.132.172.212.252.282.322.362.402.432.472.512.542.582.622.662.692.732.772.812.842.882.922.962.993.033.073.103.143.183.223.253.293.333.373.403.443.483.523.553.593.633.673.703.743.783.813.853.893.933.964.00

4.044.084.114.154.194.234.264.304.344.374.414.454.494.524.564.604.644.674.714.754.794.794.804.804.814.824.824.834.844.844.854.864.864.874.884.884.894.904.904.914.914.924.934.934.944.954.954.964.974.974.984.994.99

Total indoor unit capacity

(kW)

Cooling capacity

(kW)

Power consumption

(kW)

Total indoor unit capacity

(kW)

Cooling capacity

(kW)

Power consumption

(kW)7.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.411.511.611.711.811.912.012.112.212.312.412.512.612.712.812.9

13.013.113.213.313.413.513.613.713.813.914.014.114.214.314.414.514.614.714.814.915.015.115.215.315.415.515.615.715.815.916.016.116.216.316.416.516.616.716.816.917.017.117.217.317.417.517.617.717.817.918.018.118.2

6.97.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.510.610.710.810.911.011.111.211.311.411.511.611.711.811.912.012.112.212.312.412.512.612.7

12.812.913.013.113.213.313.413.513.613.713.813.914.014.114.214.314.414.514.614.714.814.814.814.814.814.914.914.914.914.914.914.915.015.015.015.015.015.015.015.115.115.115.115.115.115.115.115.215.215.215.215.215.2

RMK(X)S140EV1A

Page 41: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

40

Number of BP units

1 to 3 units

Number of REFNET joints

Number of BP units

123

UnnecessaryKHRP26A22T x 1KHRP26A22T x 2

Cooling capacity

Note:Cooling operation data is based on the following conditions: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB.The rated capacities above show the rise in the total indoor unit capacity when operating frequency is constant. Values for changes in capacity are fixed after accounting for variations in operating frequency and should be used as reference values.

Total indoor unit capacity

(kW)

Cooling capacity

(kW)

Power consumption

(kW)

Total indoor unit capacity

(kW)

Cooling capacity

(kW)

Power consumption

(kW)

RMK(X)S160EV1A

2.042.092.132.172.212.262.302.342.392.432.472.512.562.602.642.682.732.772.812.852.902.942.983.033.073.113.153.203.243.283.323.373.413.453.503.543.583.623.673.713.753.793.843.883.923.964.014.054.094.144.184.224.264.314.35

4.394.434.484.524.564.604.654.694.734.784.824.864.904.954.995.035.075.125.165.205.255.295.335.375.425.465.465.465.465.465.465.465.465.465.465.465.465.465.465.475.475.475.475.475.475.475.475.475.475.475.475.475.475.475.47

5.475.475.485.485.485.485.485.485.485.485.485.485.485.485.485.485.485.485.48

Total indoor unit capacity

(kW)

Cooling capacity

(kW)

Power consumption

(kW)8.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.411.511.611.711.811.912.012.112.212.312.412.512.612.712.812.913.013.113.213.313.4

13.513.613.713.813.914.014.114.214.314.414.514.614.714.814.915.015.115.215.315.415.515.615.715.815.916.016.116.216.316.416.516.616.716.816.917.017.117.217.317.417.517.617.717.817.918.018.118.218.318.418.518.618.718.818.9

19.019.119.219.319.419.519.619.719.819.920.020.120.220.320.420.520.620.720.8

7.87.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.910.911.011.111.211.311.411.511.611.711.811.912.012.112.212.312.412.512.612.712.812.913.0

13.113.213.313.413.513.613.713.813.914.014.014.114.214.314.414.514.614.714.814.915.015.115.215.315.415.515.515.515.615.615.615.615.615.615.715.715.715.715.715.815.815.815.815.815.815.915.915.915.915.916.016.016.016.016.0

16.016.116.116.116.116.116.216.216.216.216.216.216.316.316.316.316.316.416.4

Page 42: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

41

Capacity Tables

2.242.262.292.322.352.372.402.432.452.482.512.532.562.592.612.642.672.692.722.752.782.802.832.862.882.912.942.962.993.023.043.073.103.123.153.183.213.233.263.293.313.343.373.393.423.453.473.503.533.553.583.613.633.663.693.723.743.773.803.82

3.853.883.903.933.983.973.973.973.973.963.963.963.953.953.953.953.943.943.943.933.933.933.923.923.923.913.913.913.903.903.90

Total indoor unit capacity

(kW)

Heating capacity

(kW)

Power consumption

(kW)

Total indoor unit capacity

(kW)

Heating capacity

(kW)

Power consumption

(kW)5.55.65.75.85.96.06.16.26.36.46.56.66.76.86.97.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.4

11.511.611.711.811.912.012.112.212.312.412.512.612.712.812.913.013.113.213.313.413.513.613.713.813.914.014.114.214.314.414.5

6.86.97.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.89.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.411.511.611.711.811.912.012.112.212.312.412.512.612.712.812.9

13.013.113.213.313.413.513.513.513.513.513.513.613.613.613.613.613.713.713.713.713.713.713.813.813.813.813.813.813.813.913.9

RMXS112EV1A

2.702.732.762.802.832.872.902.942.973.013.043.083.113.153.183.213.253.283.323.353.393.423.463.493.533.563.603.633.663.703.733.773.803.843.873.913.943.984.014.054.084.114.154.184.224.254.294.324.364.394.434.464.504.534.564.604.634.674.704.74

4.774.814.844.884.914.954.985.015.055.085.125.155.195.175.155.145.125.105.095.075.055.045.025.014.994.974.964.944.924.914.894.874.864.844.824.814.794.774.764.744.724.714.694.674.664.644.624.614.594.574.564.544.52

Total indoor unit capacity

(kW)

Heating capacity

(kW)

Power consumption

(kW)

Total indoor unit capacity

(kW)

Heating capacity

(kW)

Power consumption

(kW)7.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.411.511.611.711.811.912.012.112.212.312.412.512.612.712.812.9

13.013.113.213.313.413.513.613.713.813.914.014.114.214.314.414.514.614.714.814.915.015.115.215.315.415.515.615.715.815.916.016.116.216.316.416.516.616.716.816.917.017.117.217.317.417.517.617.717.817.918.018.118.2

8.48.58.68.78.88.99.09.19.29.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.311.411.511.611.711.811.912.012.112.212.312.412.512.612.712.812.913.013.213.313.413.513.613.713.813.914.014.114.214.314.414.514.6

14.714.814.915.115.215.315.415.515.615.715.815.916.016.016.016.116.116.116.116.116.216.216.216.216.216.316.316.316.316.316.316.416.416.416.416.416.516.516.516.516.516.616.616.616.616.616.716.716.716.716.716.816.8

RMXS140EV1A

Heating capacity

Page 43: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

42

Note:Heating operation data is based on the following conditions: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB.The rated capacities above show the rise in the total indoor unit capacity when operating frequency is constant. Values for changes in capacity are fixed after accounting for variations in operating frequency and should be used as reference values.

Heating capacity

Total indoor unit capacity

(kW)

Heating capacity

(kW)

Power consumption

(kW)

Total indoor unit capacity

(kW)

Heating capacity

(kW)

Power consumption

(kW)

RMXS160EV1A

2.622.652.682.712.742.782.812.842.872.902.932.962.993.023.053.083.113.143.173.203.233.263.293.323.353.383.413.443.473.503.543.573.603.633.663.693.723.753.783.813.843.873.903.933.963.994.024.054.084.114.144.174.204.234.26

4.304.334.364.394.424.454.484.514.544.574.604.634.664.694.724.754.784.814.844.874.904.934.964.995.025.065.055.045.035.035.025.015.015.004.994.994.984.974.964.964.954.944.944.934.924.924.914.904.894.894.884.874.874.864.85

4.854.844.834.824.824.814.804.804.794.784.784.774.764.754.754.744.734.734.72

Total indoor unit capacity

(kW)

Heating capacity

(kW)

Power consumption

(kW)8.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.9

10.010.110.210.310.410.510.610.710.810.911.011.111.211.311.411.511.611.711.811.912.012.112.212.312.412.512.612.712.812.913.013.113.213.313.4

13.513.613.713.813.914.014.114.214.314.414.514.614.714.814.915.015.115.215.315.415.515.615.715.815.916.016.116.216.316.416.516.616.716.816.917.017.117.217.317.417.517.617.717.817.918.018.118.218.318.418.518.618.718.818.9

19.019.119.219.319.419.519.619.719.819.920.020.120.220.320.420.520.620.720.8

9.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.411.511.611.811.912.012.112.212.312.412.512.612.712.812.913.013.113.213.313.413.513.613.713.813.914.014.114.214.314.414.514.614.714.8

14.915.015.115.215.315.415.515.715.815.916.016.116.216.316.416.516.616.716.816.917.017.117.217.317.417.517.517.517.517.517.517.517.517.517.517.517.517.517.617.617.617.617.617.617.617.617.617.617.617.617.617.617.617.617.6

17.617.617.617.617.617.617.617.617.617.717.717.717.717.717.717.717.717.717.7

Page 44: Multi-Split Type Air Conditioners E Series with DC ... · with DC Inverter Power Control ... RMK(X)S160EV1A (15.5 kW) 600 x 600 ... by boosting the internal dome pressure. >> Stronger

All rights reservedPrinted in Japan 09/09/030 DNc

DealerHead Office:Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan

Tokyo Office:JR Shinagawa East Bldg., 2-18-1, Konan,Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global_ac/

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.

Cautions on product corrosion

Warning Daikin Industries, Ltd.’s products are manufactured for export to numerous countries throughout the world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a particular country. Prior to purchase, please therefore confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation.

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.

Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Specifications, designs and other content appearing in this brochure are current as of September 2009 but subject to change without notice.

Daikin AustraliaPty Limited (ISO 9001)

QEC 23256 31 May 2006

Daikin AustraliaPty Limited (ISO 14001)

CEM20437 13 November 2006JQA-1452JMI-0107

Organization:DAIKIN INDUSTRIES, LTD.AIR CONDITIONING MANUFACTURING DIVISION

Scope of Registration:THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, COMMERCIAL HEATING EQUIPMENT,RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, MARINE TYPE CONTAINER REFRIGERATION UNITS, COMPRESSORS AND VALVES.

Organization:DAIKIN INDUSTRIES (THAILAND) LTD.

Scope of Registration:THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM

All of the Daikin Group’s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management.