Top Banner
Structural blind fasteners, LockBolts, Powerigs and installation tooling for HUCK ® products RIVQUICK ® HUCK 07/17 EN ®
152

Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

Jan 19, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

Structural blind fasteners, LockBolts, Powerigs

and installation tooling for HUCK® products

RIVQUICK®

HUCK 07/17 EN

®

Page 2: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

2

Structural blind fasteners and LockBolts

HUCK® structural blind fasteners and LockBolts are specially designed and manufactured for applications wherestrength and security is key. Huck fasteners are designed to provide a permanent, vibration resistant joint andguarantee excellent performance.

These fasteners elements have a high resistance to tensile and shear strengths as well as vibrations. They are agood alternative to welding and are generally more efficient than a conventional system "nut and bolt". HUCK®

structural blind fasteners and LockBolts offer advantages that no other system can give.

Böllhoff offer a wide range of installation tools, specifically designed for installing HUCK® structural blind fastenersand LockBolts. Huck installation tooling provide a quick and secure installation. A simple visual inspection issufficient to ensure the installation is complete.

Currently the structural blind rivets and LockBolts are used in various industries and applications such as theconstruction, bus, trucks and trailers, ventilation and air conditioning systems, rail, automotive and green energy

Useful information

The company reserves the right to make changes without notice, to the products included in this catalogue,in order to improve the quality.For stock availability, please contact us.The information contained in this catalogue is provided for information only. They do not represent anyguarantee expressed, implied or legal ; all guarantees are contained exclusively in written quote, vouchersand/or purchase orders. It is recommended that the user obtains the updated data and specific informationconcerning each application.

®

Page 3: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

3

Contents

Page

Selection guide 4

Operation of HUCK® LockBolts 6

Operation of HUCK® structural blind rivets 7

Range of structural blind rivets

- Magna-Lok® 8

- Auto-Bulb™ 17

- Magna-Tite™ 18

- Magna-Bulb™ 21

- Huck-Lok™ 23

- BOM® 24

- FloorTight® 26

Range of LockBolts

- Magna-Grip® 28

- C6L® Lockbolt 38

- C120L® Lockbolt 82

- C50L® Lockbolt 94

- Hucktainer® 105

- BobTail® 110

Installation tooling 124

- Hydropneumatic tools 126

- Hydraulic tools 128

- Powerig® hydraulic unit 131

- Summary table "Tools / Nose / Fasteners” 132

Applications of HUCK® fastening systems 134

Numerical index 140

Page 4: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

4

• • • •

ProtrudingAluminiumStainless SteelSteel Countersunk Protruded

• •

Material Head

Selection guide

Magna-Lok® structural blind rivets

Wide clamping range : adaptation to a wide variation of the clamping rangeOutstanding hole filling on the blind side: Excellent joint tightness and very resistant to water ingressInternal pin locking mechanism: Secure within the rivet body and protected from corrosionNo bulge after the installation

8

• • •Auto-Bulb® structural blind rivets

High tensile and shear strengthPurpose design blind side shape for easy hole location: Ideal for automated assemblyLarge blind side footprint: Ideal for lower strength or thin sheet joint materialsVisual inspection is fast and simple.

17

•Magna-Tite® structural blind rivets

Watertight seal, ideal for roofing or similar applicationsWide clamping rangeExtra large blind side footprint: Ideal for joining of plastic and composites materials, lower strength or thin sheetjoint materialsVisual inspection is fast and simple.

18Flat profile

• •Magna-Bulb® structural blind rivets

Internal pin locking mechanism: secure within the rivet body and protected from corrosionVery high shear and high tensile strengthExtra large blind side footprint: ideal for lower strength or thin sheet joint materialsHigh resistance to vibrationsVisual inspection is fast and simple.

21

• •HuckLok™ structural blind rivets

Combines the wide clamping range of the Magna-Lok® and the high shear strength and high tensile strengthof the Magna-Bulb®

Large blind side footprint: Ideal for lower strength or thin sheet joint materialsHigh shear and tensile strength and to vibrationsWide grip rangeVisual inspection is fast and simple.

23

•BOM® structural blind rivets

Very high strength/diameter ratio: can be used in demanding structural applications as an alternative to threadedfasteners or weldingVery resistant to tampering, extremely hard to removeLarge blind side footprint: ideal for lower strength or thin sheet joint materialsVery high joint tightness when compared to conventional blind fasteners

24Standard

®

Page 5: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

5

ProtrudingAluminiumStainless SteelSteel Countersunk Protruded

Material Head

• Noyée

FloorTight® structural blind rivets

They offer a superior strength to conventional flooring screws: Reduces the number of fasteners required andnumber of drilled holesSuperior resistance rivetBreaking of the riveting stem inside the rivet: fasteners are totally flushWide clamping range

26

• • • •Magna-Grip® LockBolt

Wide clamping rangeThey offer a high resistance to vibrationsOne stem and one collar cover a wide variety of applicationsThe break of the riveting stem is always flush to the collar

28

• • • • •C6L® LockBolt

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: Enables installation into non metallic materials

38Brazier head

• • • • • Brazier head

C50L® LockBolt

Fasteners elements for difficult conditions8.8 grade large diameter LockBoltHigh resistance to vibrationsVisual inspection is fast and simple.

94

• • • Brazier head

C120L® LockBolt

8.8 grade small diameter LockBolt (improved version of C6L)High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: nnables installation into non metallic materials

82

•Hucktainer® LockBolt

Designed specifically for joining composite board in trailer applications.Will not crush or damage the composite platesIntegral seal around pin head prevents moisture ingressNo bulge on both sides after the installation

105Standardlow profile

Medium bearingcolour encapsulated

Wide bearingcolour encapsulated

•BobTail® LockBolt

No breaking of the riveting stem: increased corrosion resistance, reduced wastage, low installation noiseA better support provided by the collar and the head of the rivetSemi-automatic tooling installation: more accurate and rapidity in the installationUnique helical lock groove: Holds the collar on the stem prior to installation

110Brazier head Flanged head

Rivet

Page 6: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

6

Operation of HUCK® LockBolt

Lockbolt installation sequence

1 The stem is placed into the prepared hole. Then the collar is placed over the stem2 The tool is placed over the riveting stem and activated. The initial clamp is generated by the stem head pulledagainst the material and the collar pushed by the anvil against the joint.

3 The clamp increases, the tool swages the collar.4 The stem breaks at the predetermined breaking point, the installation is completed

Shear strength of HUCK® LockBolts vary according to the material strength and minimal diameter of the fastener.By increasing the diameter or the grade of material, the shear strength of the fastener can be increased.

The tensile strength of HUCK® LockBolts is dependent on the shear resistance of the collar material and thenumber of grooves it fills.

Head

Stem

Collar

Rivet grooves

Breakneck groove

Pull stem

Tensile

Stem-lessLockBolt after installation

LockBolt after installation

Centre Line

Shear

Shear Line

®

Page 7: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

7

Operation of HUCK® structural blind rivets

Blind Fastener installation sequence

1 First, the structural blind rivet is inserted into the drill hole and the tool is placed over the pull stem of the rivet2 The tool is activated, the deforming of blind rivet side begins3 Joint tightened and the internal locking mechanism formed4 The stem breaks at the predetermined breaking point and installation is complete.

The shear strength of structural blind fasteners is generated by the combined resistance against failure of thestem and sleeve. This takes place along the joint’s shear line between fastened plates.

The tensile strength of structural blind fasteners differs to that of Lockbolts, as they form a blind side positive lockeither by bulbing or expanding of the sleeve. The sleeve, assisted by the permanently secured stem, thereforeresists failure along its centre line.

1. Bulbing – the sleeve of the fastener is compressed, causing it to fold outwards to form a bulb. This forms itselftightly against the joint material. Once the stem is permanently locked into place the stem will break off,completing the installation.

2. Expanding – pulling on the stem causes the head of the stem to draw into the sleeve. This expansion causesa foot print to form against the joint material.

Tensile

Bulbing(Magna-Bulb®)

Expanding(HuckLok®)

Centre Line

Shear

Shear Line

Sleeve

Pull stem

Head of stem

Page 8: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

4,85 - 5,11

1,57 - 6,86

2,2 2,7 0,3

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

>< >

<><

8

4,84,76

9,78 2,16

MGLP-B6-418,295,44 - 11,10 MGLP-B6-722,3514,27 - 19,02 MGLP-B6-1230,331,57 - 11,10 MGLP-B6-E25,91

6,63 - 6,91

2,03 - 6,35

4,0 5,8 0,46,46,35

13,44 3,02

MGLP-B8-418,292,03 - 9,53 MGLP-B8-624,648,89 - 15,88 MGLP-B8-1030,9914,73 - 22,2321,08 - 28,5827,43 - 34,932,03 - 15,88

MGLP-B8-14MGLP-B8-18MGLP-B8-22MGLP-B8-E

37,3443,6950,0435,69

9,96 - 10,363,05 - 15,88

8,5 13,1 1,19,59,53

20,14 4,47MGLP-B12-1241,91

13,49 - 14,30 4,06 - 19,05 18,2 22,06 1,712,7 26,92 6,10 MGLP-B16-1250,80

15,88 - 28,58 MGLP-B12-1856,2625,4 - 38,10 MGLP-B12-2465,79

Range of structural blind rivets

Wide clamping range: adaptation to a wide variation of the clamping rangeOutstanding hole filling on the blind side: Excellent joint tightness and very resistant to water ingressInternal pin locking mechanism: Secure within the rivet body and protected from corrosionHigh shear and tensile strengthNo bulge after the installation Visual inspection is fast and simple.

Magna-Lok® - Aluminium

®

Body : Aluminium | Stem : Aluminium | Head : Protruding

> <k

(mm)

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

Stemholding

kNmin

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 9: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

9

4,85 - 5,11

1,57 - 6,86

4,4 5,8 0,7

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Stemholding

kNmin

kNmin

>

>

>< >

<><

4,84,76

9,78 2,16

MGLP-R6-418,295,44 - 11,10 MGLP-R6-722,3514,27 - 19,02 MGLP-R6-1230,331,57 - 11,10 MGLP-R6-E25,91

6,63 - 6,91 8,2 11,1 1,36,46,35

13,44 3,02

MGLP-R8-624,64 2,03 - 9,53MGLP-R8-1030,99 8,89 - 15,88MGLP-R8-1437,34 14,73 - 22,23

21,08 - 28,5827,43 - 34,932,03 - 15,88

MGLP-R8-18MGLP-R8-22MGLP-R8-E

43,6950,0435,69

9,96 - 10,363,05 - 15,88

17,8 26,7 2,79,59,53

20,14 4,47MGLP-R12-1241,91

13,49 - 14,30 4,06 - 19,05 31,1 44,4 4,512,7 26,92 6,10 MGLP-R16-1250,80

15,88 - 28,58 MGLP-R12-1856,2625,4 - 38,10 MGLP-R12-2465,79

Wide clamping range: adaptation to a wide variation of the clamping rangeOutstanding hole filling on the blind side: Excellent joint tightness and very resistant to water ingressInternal pin locking mechanism: Secure within the rivet body and protected from corrosionHigh shear and tensile strengthNo bulge after the installation Visual inspection is fast and simple.

Magna-Lok® - Steel

Body : Steel | Stem : Steel | Head : Protruding

> <k

(mm)

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 10: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

4,85 - 5,11

1,57 - 6,86

4,2 5,8 0,4

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

>< >

<><

10

4,84,76

9,96 2,57

MGLP-U6-410,525,44 - 11,10 MGLP-U6-714,5311,56 - 16,89 MGLP-U6-1020,451,57 - 11,10 MGLP-U6-E14,535,44 - 13,46 MGLP-U6-E817,025,44 - 15,04 MGLP-U6-E918,596,35 - 16,89 MGLP-U6-E1020,45

6,63 - 6,91

2,03 - 6,35

8,0 10,5 0,96,46,35

13,44 3,02

MGLP-U8-418,292,03 - 9,53 MGLP-U8-623,372,03 - 11,10 MGLP-U8-724,898,89 - 15,882,03 - 15,88

MGLP-U8-10MGLP-U8-E

30,9935,69

9,96 - 10,363,05 - 15,88

8,5 13,1 1,19,59,53

20,14 4,47MGLP-4U12-1241,91

15,88 - 28,58 MGLP-U12-1856,26

Range of structural blind rivets

Wide clamping range: adaptation to a wide variation of the clamping rangeOutstanding hole filling on the blind side: Excellent joint tightness and very resistant to water ingressInternal pin locking mechanism: Secure within the rivet body and protected from corrosionHigh shear and tensile strengthNo bulge after the installation Visual inspection is fast and simple.

Magna-Lok® - Stainless steel

Magna-Lok® - Stainless steel A4

®

Body : Stainless steel | Stem : Stainless steel | Head : Protruding

> <k

(mm)

Stemholding

kNmin

6,62 - 6,90 2,03 - 9,53 8,0 10,5 0,88

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

>< >

<><

6,46,35

13,44 3,02 MGLP-316U8-623,37

Body : Stainless steel A4 | Stem : Stainless steel A4 | Head : Protruding

> <k

(mm)

Stemholding

kNmin

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 11: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

11

4,85 - 5,111,57 - 6,86

2,2 2,7 0,3

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

>< >

<>< > <k

(mm)

Stemholding

kNmin

4,84,76

13,49 2,34MGLT-B6-418,03

5,44 - 11,10 MGLT-B6-721,971,57 - 11,10 MGLT-B6-E25,78

6,63 - 6,91 4,0 5,8 0,46,46,35

15,04 3,02MGLT-B8-624,64 2,03 - 9,53MGLT-B8-1030,99 8,89 - 15,88MGLT-B8-E35,69 2,03 - 15,88

9,96 - 10,363,05 - 14,22

8,5 13,1 1,19,59,53

22,78 4,47MGLT-B12-1241,91

25,4 - 38,10 MGLT-B12-2465,79

Wide clamping range : adaptation to a wide variation of the clamping rangeOutstanding hole filling on the blind side: Excellent joint tightness and very resistant to water ingressInternal pin locking mechanism: Secure within the rivet body and protected from corrosionHigh shear and tensile strengthNo bulge after the installation Visual inspection is fast and simple.

Magna-Lok® - Aluminium

Body : Aluminium | Stem : Aluminium | Head : Protruded

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 12: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

12

4,85 - 5,111,57 - 6,86

4,4 5,8 0,7

12

4,84,76

13,49 2,34MGLT-R6-418,03

5,44 - 11,10 MGLT-R6-721,971,57 - 11,10 MGLT-R6-E25,78

6,63 - 6,912,03 - 9,53

8,2 11,1 1,36,46,35

15,04 3,02MGLT-R8-624,64

8,89 - 15,88 MGLT-R8-1030,992,03 - 15,88 MGLT-R8-E35,69

Range of structural blind rivets

Wide clamping range: adaptation to a wide variation of the clamping rangeOutstanding hole filling on the blind side: Excellent joint tightness and very resistant to water ingressInternal pin locking mechanism: Secure within the rivet body and protected from corrosionHigh shear and tensile strengthNo bulge after the installation Visual inspection is fast and simple.

Magna-Lok® - Steel

®

Body : Steel | Stem : Steel | Head : Protruded

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

>< >

<>< > <k

(mm)

Stemholding

kNmin

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 13: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

1313

6,63 - 6,912,03 - 9,53

8,0 10,5 0,96,46,35

15,04 3,02MGLT-U8-624,64

8,89 - 15,88 MGLT-U8-1030,992,03 - 15,88 MGLT-U8-E35,69

Wide clamping range: adaptation to a wide variation of the clamping rangeOutstanding hole filling on the blind side: Excellent joint tightness and very resistant to water ingressInternal pin locking mechanism: Secure within the rivet body and protected from corrosionHigh shear and tensile strengthNo bulge after the installation Visual inspection is fast and simple.

Magna-Lok® - Stainless Steel

Body : Stainless steel | Stem : Stainless steel | Head : Protruded

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

>< >

<>< > <k

(mm)

Stemholding

kNmin

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

Page 14: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

14

4,85 - 5,113,18 - 8,41

4,4 5,8 0,7

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

>< >

<><

14

4,84,76

8,89 1,93MGL100-R6-620,19

7,75 - 12,70 MGL100-R6-924,43

6,63 - 6,914,06 - 12,07

8,2 11,1 1,36,46,35

10,41 2,16MGL100-R8-826,90

10,54 - 18,42 MGL100-R8-1233,259,96 - 10,36 6,10 - 19,05 17,79 26,7 2,669,5 15,93 3,38 MGL100-R12-1242,4213,49 - 14,30 10,03 - 19,05 31,1 44,4 4,512,7 22,10 5,00 MGL100-R16-1256,77

Range of structural blind rivets

Wide clamping range: adaptation to a wide variation of the clamping rangeOutstanding hole filling on the blind side: Excellent joint tightness and very resistant to water ingressInternal pin locking mechanism: Secure within the rivet body and protected from corrosionHigh shear and tensile strengthNo bulge after the installation Visual inspection is fast and simple.

Magna-Lok® - Steel

®

Body : Steel | Stem : Steel | Head : Countersunk

> <k

(mm)

Stemholding

kNmin

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 15: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

1515

4,85 - 5,11

3,18 - 8,41

2,2 2,7 0,3

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Stemholding

kNmin

kNmin

>

>

>< >

<><

4,84,76

8,89 1,93

MGL100-B6-620,197,75 - 12,70 MGL100-B6-924,4312,32 - 16,99 MGL100-B6-1228,6815,49 - 20,17 MGL100-B6-1431,,85

6,63 - 6,914,06 - 12,07

4,0 5,8 0,46,46,35

10,41 2,16MGL100-B8-826,90

10,54 - 18,42 MGL100-B8-1233,2513,46 - 27,18 MGL100-B8-E1741,15

Wide clamping range: adaptation to a wide variation of the clamping rangeOutstanding hole filling on the blind side: Excellent joint tightness and very resistant to water ingressInternal pin locking mechanism: Secure within the rivet body and protected from corrosionHigh shear and tensile strengthNo bulge after the installation Visual inspection is fast and simple.

Magna-Lok® - Aluminium

Body : Aluminium | Stem : Aluminium | Head : Countersunk

> <k

(mm)

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 16: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

16

4,85 - 5,113,18 - 8,41

4,2 5,8 0,4

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

>< >

<><

16

4,84,76

8,89 1,93MGL100-U6-619,35

7,75 - 12,70 MGL100-U6-923,60

6,63 - 6,914,06 - 12,07

8,0 10,5 0,96,46,35

10,41 2,16MGL100-U8-826,90

10,54 - 18,42 MGL100-U8-1233,25

Range of structural blind rivets

Wide clamping range: adaptation to a wide variation of the clamping rangeOutstanding hole filling on the blind side: Excellent joint tightness and very resistant to water ingressInternal pin locking mechanism: Secure within the rivet body and protected from corrosionHigh shear and tensile strengthNo bulge after the installation Visual inspection is fast and simple.

Magna-Lok® - Inox

®

Body : Stainless Steel | Stem : Stainless Steel | Head : Countersunk

> <k

(mm)

Stemholding

kNmin

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 17: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

1717

4,9 - 5,1

1,9 - 2,8

3,8 5,3 0,7

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Stemholding

kNmin

kNmin

>

>

>< >

<><

4,8 9,9 2,3

ABP-R6-M212,02,2 - 3,8 ABP-R6-M313,03,2 - 4,8 ABP-R6-M414,04,2 - 5,8 ABP-R6-M515,0

6,6 - 6,9

1,5 - 3,5

7,1 11,6 1,36,4 13,4 3,2

ABP-R8-M215,82,8 - 4,8 ABP-R8-M317,03,8 - 5,8 ABP-R8-M418,14,8 - 6,8 ABP-R8-M519,15,8 - 7,8 ABP-R8-M620,16,8 - 8,8 ABP-R8-M721,17,8 - 9,8 ABP-R8-M822,18,8 - 10,8 ABP-R8-M923,19,8 - 11,8 ABP-R8-M1024,110,8 - 12,8 ABP-R8-M1125,118,8 - 20,8

1,5 - 3,52,8 - 4,83,8 - 5,84,8 - 6,85,8 - 7,86,8 - 8,87,8 - 9,88,8 - 10,89,8 - 11,810,8 - 12,818,8 - 20,8

ABP-R8-M1933,2

High tensile and shear strengthPurpose design blind side shape for easy hole location: Ideal for automated assemblyLarge blind side footprint: Ideal for lower strength or thin sheet joint materialsVisual inspection is fast and simple.

Auto-BulbTM - Steel

Auto-BulbTM - Stainless Steel

Body : Steel | Stem : Steel | Head : Protruded

> <k

(mm)

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Stemholding

kNmin

kNmin

>

>

>< >

<><

6,6 - 6,9 8,54 15,1 1,36,412,42 -13,59

2,64 -3,30

ABP-4U8-M215,05ABP-4U8-M316,35ABP-4U8-M417,35ABP-4U8-M518,35ABP-4U8-M619,35ABP-4U8-M720,35ABP-4U8-M821,35ABP-4U8-M922,35ABP-4U8-M1023,35ABP-4U8-M1225,35ABP-4U8-M1932,35

Body : Stainless steel | Stem : Stainless steel | Head : Protruded

> <k

(mm)

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 18: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

1818

Range of structural blind rivets®

Watertight seal, ideal for roofing or similar applicationsWide clamping rangeExtra large blind side footprint: Ideal for joining of plastic and composites materials, lower strength orthin sheet joint materialsVisual inspection is fast and simple.

Magna-TiteTM - Aluminium

5,2 - 5,6

1,3 - 7,9

1,7 2,4 0,3

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Stemholding

kNmin

kNmin

>

>

>< >

<><

4,8 11,8 3,0

MTP-B6-5S25,92,5 - 9,5 MTP-B6-6S27,26,4 - 12,7 MTP-B6-8S31,09,5 - 15,9 MTP-B6-10S34,212,7 - 19,1 MTP-B6-12S37,3

6,4 - 6,7

1,0 - 6,4

2,6 4,2 0,36,4 13,7 3,2

MTP-B8-4S25,23,2 - 9,5 MTP-B8-6S28,53,0 - 10,4 MTP-B8-7S29,26,4 - 12,7 MTP-B8-8S31,59,5 - 15,9 MTP-B8-10S34,712,7 - 19,1 MTP-B8-12S37,9

Body : Aluminium | Stem : Aluminium

> <k

(mm)

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 19: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

1919

5,2 - 5,6

1,3 - 6,4

1,7 1,3 0,3

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Stemholding

kNmin

kNmin

>

>

>< >

<><

4,8 11,5 1,3

MTLP-B6-424,64,8 - 12,7 MTLP-B6-831,09,5 - 19,1 MTLP-B6-1235,31,3 - 19,1 MTLP-B6-12X35,3

Watertight seal, ideal for roofing or similar applicationsWide clamping rangeExtra large blind side footprint: Ideal for joining of plastic and composites materials, lower strength orthin sheet joint materialsVisual inspection is fast and simple.

Magna-TiteTM - Aluminium

Body : Aluminium | Stem : Aluminium | Head : Low Profile head

> <k

(mm)

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

Page 20: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

2020

Range of structural blind rivets®

Watertight seal, ideal for roofing or similar applicationsWide clamping rangeExtra large blind side footprint: Ideal for joining of plastic and composites materials, lower strength orthin sheet joint materialsVisual inspection is fast and simple.

Magna-TiteTM - Aluminium

5,2 - 5,6

1,8 - 7,9

1,7 2,4 0,3

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Stemholding

kNmin

kNmin

>

>

>< >

<><

4,8 8,7 3,0

MTV-B6-5S26,44,1 - 10,4 MTV-B6-7S29,06,4 - 12,7 MTV-B6-8S31,09,5 - 15,9 MTV-B6-10S34,212,7 - 19,1 MTV-B6-12S37,3

Body : Aluminium | Stem : Aluminium

> <k

(mm)

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

Page 21: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

2121

Internal pin locking mechanism: secure within the rivet body and protected from corrosionVery high shear and high tensile strengthExtra large blind side footprint: ideal for lower strength or thin sheet joint materialsHigh resistance to vibrationsVisual inspection is fast and simple.

Magna-BulbTM - Steel

4,9 - 5,1

2,2 - 2,8

4,7 8,7 0,7

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Stemholding

kNmin

kNmin

>

>

>< >

<><

4,8 9,9 2,6

MBP-R6-M215,02,2 - 3,8 MBP-R6-M317,13,2 - 4,8 MBP-R6-M417,74,2 - 5,8 MBP-R6-M518,65,2 - 6,8 MBP-R6-M619,76,2 - 7,8 MBP-R6-M720,77,2 - 8,8 MBP-R6-M821,78,2 - 9,8 MBP-R6-M922,79,2 - 10,8 MBP-R6-M1023,710,2 - 11,8 MBP-R6-M1124,711,2 - 12,8 MBP-R6-M1225,712,2 - 13,8 MBP-R6-M1326,713,2 - 14,8 MBP-R6-M1427,7

6,6 - 6,9

1,5 - 3,5

8,5

11,612,012,313,314,2

15,6

1,36,4 13,4 3,2

MBP-R8-M219,32,8 - 4,8 MBP-R8-M321,93,8 - 5,8 MBP-R8-M423,94,8 - 6,8 MBP-R8-M523,25,8 - 7,8 MBP-R8-M623,96,8 - 8,8 MBP-R8-M724,97,8 - 9,8 MBP-R8-M825,98,8 - 10,8 MBP-R8-M926,99,8 - 11,8 MBP-R8-M1027,910,8 - 12,8 MBP-R8-M1128,911,8 - 13,8 MBP-R8-M1230,012,8 - 14,8 MBP-R8-M1330,918,8 - 20,8 MBP-R8-M1937,131,8 - 33,8 MBP-R8-M3250,3

8,3 - 8,6

3,8 - 6,4

13,2 22,2 2,17,9 16,8 3,9

MBP-R10-328,15,1 - 7,6 MBP-R10-429,36,4 - 8,9 MBP-R10-530,67,6 - 10,2 MBP-R10-631,98,9 - 11,4 MBP-R10-733,210,2 - 12,7 MBP-R10-834,411,4 - 14,0 MBP-R10-935,712,7 - 15,2 MBP-R10-1037,0

Body : Steel | Stem : Steel | Head : Protruded

> <k

(mm)

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 22: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

2222

Range of structural blind rivets®

4,9 - 5,1

1,9 - 2,8

4,7 8,7 0,7

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Stemholding

kNmin

kNmin

>

>

>< >

<><

4,8 9,9 2,6

MBCP-R6-M29,4MBCP-R6-M311,4MBCP-R6-M412,0MBCP-R6-M513,0MBCP-R6-M614,1MBCP-R6-M715,0MBCP-R6-M816,1MBCP-R6-M917,0MBCP-R6-M1018,0

6,6 - 6,9 7,1

10,210,711,1

13,3

1,36,4 13,4 3,2

MBCP-R8-M213,1MBCP-R8-M315,7MBCP-R8-M417,7MBCP-R8-M517,0MBCP-R8-M618,0MBCP-R8-M719,0MBCP-R8-M820,0MBCP-R8-M921,0

10,8 - 12,8 MBCP-R8-M1123,012,8 - 14,8 MBCP-R8-M1325,015,8 - 17,8 MBCP-R8-M1628,018,8 - 20,8 MBCP-R8-M1931,024,8 - 26,8 MBCP-R8-M2537,130,8 - 32,8 MBCP-R8-M3143,0

Internal pin locking mechanism: secure within the rivet body and protected from corrosionVery high shear and high tensile strengthExtra large blind side footprint: ideal for lower strength or thin sheet joint materialsHigh resistance to vibrationsVisual inspection is fast and simple.

Magna-BulbTM - Steel

Body : Steel | Stem : Steel | Head : Protruded

> <k

(mm)

2,2 - 3,83,2 - 4,84,2 - 5,85,2 - 6,86,2 - 7,87,2 - 8,88,2 - 9,89,2 - 10,81,5 - 3,52,8 - 4,83,8 - 5,84,8 - 6,85,8 - 7,86,8 - 8,87,8 - 9,88,8 - 10,8

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

Page 23: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

2323

4,9 - 5,11,6 - 7,9

4,4 8,5 0,7

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Stemholding

kNmin

kNmin

>

>

>< >

<><

4,8 9,9 2,6HKLP-R6-5U22,9

4,8 - 11,12,0 - 9,5

HKLP-R6-726,0

6,6 - 6,9 8,5

5,85,8

15,6 1,86,4 11,9 3,0

HKLP-R8-6*28,34,8 - 11,1 HKLP-R8-729,97,1 - 13,5 HKLP-R8-8,530,99,5 - 15,9 HKLP-R8-1034,712,7 - 19,1 HKLP-R8-1237,915,9 - 22,2 HKLP-R8-1441,122,2 - 28,6 HKLP-R8-1847,425,4 - 31,8 HKLP-R8-2050,6

Combines the wide clamping range of the Magna-Lok® and the high shear strength and high tensile strengthof the Magna-Bulb®

Large blind side footprint: Ideal for lower strength or thin sheet joint materialsHigh shear and tensile strength and to vibrationsWide grip rangeVisual inspection is fast and simple.

HuckLokTM - Steel

Body : Steel | Stem : Steel | Head : Protruded

> <k

(mm)

*For best results, it is recommended for thicknesses less than 2.5 mm to use the minimum hole size

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 24: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

2424

Range of structural blind rivets®

5,3 - 5,6

2,4 - 4,0

8,0 12,5

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

>< >

<

><

4,84,8 - 5,2 7,2 4,2

BOM-R6-212,74,0 - 5,6 BOM-R6-314,35,6 - 7,1 BOM-R6-415,97,2 - 8,7 BOM-R6-517,58,8 - 10,3 BOM-R6-619,110,3 - 11,9 BOM-R6-720,611,9 - 13,5 BOM-R6-822,213,5 - 15,1 BOM-R6-923,815,1 - 16,7 BOM-R6-1025,416,7 - 18,3 BOM-R6-1127,018,3 - 19,82,4 - 4,04,0 - 5,65,6 - 7,17,2 - 8,78,8 - 10,310,3 - 11,911,9 - 13,513,5 - 15,115,1 - 16,716,7 - 18,318,3 - 19,8

BOM-R6-1228,6

7,0 - 7,4 14,5 22,76,46,4 - 7,0 9,7 5,6

BOM-R8-215,8BOM-R8-317,3BOM-R8-418,9BOM-R8-520,5BOM-R8-622,1BOM-R8-723,7BOM-R8-825,3BOM-R8-926,9BOM-R8-1028,5BOM-R8-1130,0BOM-R8-1231,6

19,9 - 21,4 BOM-R8-1333,221,5 - 23,0 BOM-R8-1434,84,8 - 7,9

8,8 - 9,4 23,1 35,87,97,9 - 8,8 12,2 7,1

BOM-R10-422,28,0 - 11,1 BOM-R10-625,411,1 -14,3 BOM-R10-828,614,3 - 17,5 BOM-R10-1031,817,5 - 20,6 BOM-R10-1234,920,7 - 23,8 BOM-R10-1438,123,8 - 27,0 BOM-R10-1641,3

Very high strength/diameter ratio: can be used in demanding structural applications as an alternativeto threaded fasteners or weldingVery resistant to tampering, extremely hard to removeLarge blind side footprint: ideal for lower strength or thin sheet joint materialsVery high joint tightness when compared to conventional blind fasteners

BOM® - Steel

Body : Steel | Stem : Steel

> <k

(mm)

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 25: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

2525

10,5 - 11,1

4,8 - 7,9

32,3 49,4

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

>< >

<

><

9,59,5 - 10,4 14,4 8,3

BOM-R12-424,68,0 - 11,1 BOM-R12-627,811,1 -14,3 BOM-R12-831,014,3 - 17,5 BOM-R12-1034,117,5 - 20,6 BOM-R12-1237,320,7 - 23,8 BOM-R12-1440,523,8 - 27,0 BOM-R12-1643,727,0 - 30,2 BOM-R12-1846,830,2 - 33,36,4 - 9,5

BOM-R12-2050,0

13,9 - 14,8 57,8 89,612,712,7 - 13,9 19,1 11,1

BOM-R16-432,29,6 - 12,7 BOM-R16-635,312,7 - 15,9 BOM-R16-838,515,9 - 19,1 BOM-R16-1041,719,1 - 22,2 BOM-R16-1244,922,3 - 25,4 BOM-R16-1448,025,4 - 28,6 BOM-R16-1651,228,6 - 31,8 BOM-R16-1854,431,8 - 34,9 BOM-R16-2057,635,0 - 38,1 BOM-R16-2260,738,1 - 41,3 BOM-R16-2463,96,4 - 12,7

17,5 - 18,5 91,2 126,815,915,9 - 17,3 23,9 13,8

BOM-R20-4GA38,912,7 - 19,1 BOM-R20-8GA45,219,1 - 25,4 BOM-R20-12GA51,625,4 - 31,8 BOM-R20-16GA57,931,8 - 38,1 BOM-R20-20GA64,36,4 - 12,7

21,0 - 22,2 129,4 200,619,119,1 - 20,8 28,6 16,6

BOM-R24-4GA44,512,7 - 19,1 BOM-R24-8GA50,819,1 - 25,4 BOM-R24-12GA57,225,4 - 31,8 BOM-R24-16GA63,5

Very high strength/diameter ratio: can be used in demanding structural applications as an alternativeto threaded fasteners or weldingVery resistant to tampering, extremely hard to removeLarge blind side footprint: ideal for lower strength or thin sheet joint materialsVery high joint tightness when compared to conventional blind fasteners

BOM® - Steel

Body : Steel | Stem : Steel

> <k

(mm)

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 26: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

2626

Range of structural blind rivets®

*19,05 - 34,93

13,3 19,1 *

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Stemholding

kNmin

kNmin

>

>

>< >

<

><

8,38,26 * *

PMF-R10-2053,9819,05 - 41,28 PMF-R10-2663,50

The flooring specialist fastenerThey offer a superior strength to conventional flooring screws: reduces the number of fasteners required andnumber of drilled holesHigh strength of structural rivetsBreaking of the riveting stem inside the rivet : fasteners are totally flushWide clamping range

FloorTight® - Steel

Body : Steel | Stem : Steel | Installation into plywood

><k

(mm)

* For more information, please contact us - For values of the category F, consult us.

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 27: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

2727

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Stemholding

kNmin

kNmin

>

>

>< >

<

>< ><k

(mm)

* For more information, please contact us - For values of the category F, consult us.

8,3 - 8,6

19,1 - 34,9

12,5 15,6 0,9

8,37,90

17,5 1,7

PWFLC-R10-2050,819,1 - 41,319,1 - 34,919,1 - 41,319,1 - 34,919,1 - 41,3

PWFLC-R10-2660,350,860,350,860,3

8,37,90

PWFMC-R10-20PWFMC-R10-26

8,37,90

PWF-R10-20PWF-R10-26

The flooring specialist fastenerThey offer a superior strength to conventional flooring screws: reduces the number of fasteners required andnumber of drilled holesHigh strength of structural rivetsBreaking of the riveting stem inside the rivet : fasteners are totally flushWide clamping range

FloorTight® - Steel

Body : Steel | Stem : Steel | Installation into plywood

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 28: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

2828

Range of LockBolt®

5,0 - 5,21,6 - 15,9

7,3 7,7 4,1

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Clampload

kNkNmin

>

>

>< >

<

><

><

4,84,65 - 4,75 10,0 3,2

MGPB-R6-10GMGC-R6U MGCS-R6U MGCW-R6U

46,37,9 - 31,8 MGPB-R6-20G51,9

6,6 - 6,71,6 - 15,9

13,3 9,8 5,36,46,22 - 6,32 13,2 3,9

MGPB-R8-10GMGC-R8U MGCS-R8U MGCW-R8U

50,87,9 - 31,8 MGPB-R8-20G65,9

8,2 - 8,33,2 - 19,1

20,5 13,3 9,67,97,80 - 7,90 16,5 5,1

MGPB-R10-12GMGC-R10U - -

60,315,9 - 34,9 MGPB-R10-22G73,0

9,8 - 9,93,2 - 22,2

28,9 18,7 14,29,59,37 - 9,53 19,8 6,3

MGPB-R12-14GMGC-R12U - -

74,620,6 - 41,3 MGPB-R12-26G89,8

Wide clamping rangeThey offer a high resistance to vibrationsOne stem and one collar cover a wide variety of applicationsThe break of the riveting stem is always flush to the collar

Magna-Grip® - Steel

Stem : Steel | Head : Button

> <k

(mm)

For values of the category F, consult us.

Standard Medium Wide

MGC-R6U MGC-R8U MGCS-R6U MGCW-R6U

MGC-R10U MGC-R12U

References of the collar

Standard Medium Wide

10 mm

7,4 mm

><

><

13,2 mm

9,9 mm

><

><

13,7 mm

8,1 mm

><

><

19,3 mm

8,1 mm

><

MGCW-R8U

><

25,5 mm

11,9 mm

><

MGCS-R8U

><

16,3 mm

11,9 mm

><><

16,4 mm

11,5 mm

><

><

19,6 mm

13,2 mm

><

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 29: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

2929

Wide clamping rangeThey offer a high resistance to vibrationsOne stem and one collar cover a wide variety of applicationsThe break of the riveting stem is always flush to the collar

Magna-Grip® - Aluminium

5,0 - 5,21,6 - 15,9

4,0 3,3 2,4

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Clampload

kNkNmin

>

>

>< >

<

><

4,84,65 - 4,75 10,0 3,2

MGPB-E6-10MGC-F6 MGCS-F6 MGCW-F6

46,37,9 - 31,8 MGPB-E6-2051,9

6,6 - 6,71,6 - 15,9

7,2 5,3 4,26,46,22 - 6,32 13,2 3,9

MGPB-E8-10MGC-F8 MGCS-F8 MGCW-F8

50,87,9 - 31,8 MGPB-E8-2065,9

8,2 - 8,33,2 - 19,1

11,1 9,8 7,17,97,80 - 7,90 16,5 5,1

MGPB-E10-12MGC-F10 - -

60,315,9 - 34,9 MGPB-E10-2273,0

9,8 - 9,93,2 - 22,2

17,8 13,3 10,79,59,37 - 9,53 19,8 6,3

MGPB-E12-14MGC-F12 - -

74,620,6 - 41,3 MGPB-E12-2689,8

> <k

(mm)

References of the collar

Standard Medium Wide

Stem : Aluminium | Head : Button

For values of the category F, consult us.

><

Standard Medium Wide

MGC-F6 MGC-F8 MGCS-F6 MGCW-F6

MGC-F10 MGC-F12

9,8 mm

7,2 mm

><

><

13,2 mm

9,9 mm

><

><

13,7 mm

8,1 mm

><

><

19,2 mm

8,1 mm

><

MGCW-F8

><

25,5 mm

11,7 mm

><

MGCS-F8

><

16,3 mm

11,9 mm

><><

16,4 mm

11,3 mm

><

><

19,6 mm

13,2 mm

><

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 30: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

3030

Range of LockBolt®

Wide clamping rangeThey offer a high resistance to vibrationsOne stem and one collar cover a wide variety of applicationsThe break of the riveting stem is always flush to the collar

Magna-Grip® - Steel

Stem : Steel | Head : Countersunk

For values of the category F, consult us.

5,0 - 5,22,7 - 15,9

7,3 7,7 4,1

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Clampload

kNkNmin

>

>

>< >

<

><

4,84,65 - 4,75 9,1

2,62,23,32,94,13,65,04,3

MGP90-R6-10GMGC-R6U MGCS-R6U MGCW-R6U

46,37,9 - 31,8 MGP90-R6-20G65,9

6,6 - 6,73,3 - 15,9

13,3 9,8 5,36,46,22 - 6,32 12,1

MGP90-R8-10GMGC-R8U MGCS-RU8 MGCW-R8U

50,87,9 - 31,8 MGP90-R8-20G65,9

8,2 - 8,34,2 - 19,1

20,5 13,3 9,67,97,80 - 7,90 15,1

MGP90-R10-12GMGC-R10U - -

59,215,9 - 34,9 MGP90-R10-22G71,9

9,8 - 9,96,4 - 22,2

28,9 18,7 14,29,59,37 - 9,53 18,1

MGP90-R12-14GMGC-R12U - -

73,920,6 - 41,3 MGP90-R12-26G89,8

> <k

(mm)

References of the collar

Standard Medium Wide

><

Standard Medium Wide

MGC-R6U MGC-R8U MGCS-R6U MGCW-R6U

MGC-R10U MGC-R12U

10 mm

7,4 mm

><

><

13,2 mm

9,9 mm

><

><

13,7 mm

8,1 mm

><

><

19,3 mm

8,1 mm

><

MGCW-R8U

><

25,5 mm

11,9 mm

><

MGCS-R8U

><

16,3 mm

11,9 mm

><><

16,4 mm

11,5 mm

><

><

19,6 mm

13,2 mm

><

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 31: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

3131

Wide clamping rangeThey offer a high resistance to vibrationsOne stem and one collar cover a wide variety of applicationsThe break of the riveting stem is always flush to the collar

Magna-Grip® - Aluminium

Stem : Aluminium | Head : Countersunk

For values of the category F, consult us.

5,0 - 5,22,7 - 15,9

4,0 3,3 2,4

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Clampload

kNkNmin

>

>

>< >

<

><

4,84,65 - 4,75 9,1

2,62,23,32,94,13,65,04,3

MGP90-E6-10MGC-F6 MGCS-F6 MGCW-F6

46,37,9 - 31,8 MGP90-E6-2065,9

6,6 - 6,73,3 - 15,9

7,2 5,3 4,26,46,22 - 6,32 12,1

MGP90-E8-10MGC-F8 MGCS-F8 MGCW-F8

50,87,9 - 31,8 MGP90-E8-2065,9

8,2 - 8,34,2 - 19,1

11,1 9,8 7,17,97,80 - 7,90 15,1

MGP90-E10-12MGC-F10 - -

59,215,9 - 34,9 MGP90-E10-2271,9

9,8 - 9,96,4 - 22,2

17,8 13,3 10,79,59,37 - 9,53 18,1

MGP90-E12-14MGC-F12 - -

73,920,6 - 41,3 MGP90-E12-2689,8

> <k

(mm)

Réf. des bagues

Standard Medium Wide

><

Standard Medium Wide

MGC-F6 MGC-F8 MGCS-F6 MGCW-F6

MGC-F10 MGC-F12

9,8 mm

7,2 mm

><

><

13,2 mm

9,9 mm

><

><

13,7 mm

8,1 mm

><

><

19,2 mm

8,1 mm

><

MGCW-F8

><

25,5 mm

11,7 mm

><

MGCS-F8

><

16,3 mm

11,9 mm

><><

16,4 mm

11,3 mm

><

><

19,6 mm

13,2 mm

><

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 32: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

3232

Range of LockBolt®

5,0 - 5,21,6 - 15,9

7,3 7,7 4,1

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Clampload

kNkNmin

>

>

>< >

<

><

4,84,65 - 4,75 12,4 2,7

MGP98T-R6-10GMGC-R6U MGCS-R6U MGCW-R6U

46,37,9 - 31,8 MGP98T-R6-20G61,1

Wide clamping rangeThey offer a high resistance to vibrationsOne stem and one collar cover a wide variety of applicationsThe break of the riveting stem is always flush to the collar

Magna-Grip® - Steel

Stem : Steel | Head : Rivet

> <k

(mm)

For values of the category F, consult us.

References of the collar

Standard Medium Wide

><

Standard Medium Wide

MGC-R6U MGCS-R6U MGCW-R6U

10 mm

7,4 mm

><

><

13,7 mm

8,1 mm

><

><

19,3 mm

8,1 mm

><

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 33: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

3333

Wide clamping rangeThey offer a high resistance to vibrationsOne stem and one collar cover a wide variety of applicationsThe break of the riveting stem is always flush to the collar

Magna-Grip® - Aluminium

5,0 - 5,21,6 - 15,9

4,0 3,3 2,4

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Clampload

kNkNmin

>

>

>< >

<

><

4,84,65 - 4,75 12,4 2,7

MGP98T-E6-10MGC-F6 MGCS-F6 MGCW-F6

46,37,9 - 31,8 MGP98T-E6-2061,1

> <k

(mm)

For values of the category F, consult us.

References of the collar

Standard Medium Wide

Stem : Aluminium | Head : Rivet

><

Standard Medium Wide

MGC-F6 MGCS-F6 MGCW-F6

9,8 mm

7,2 mm

><

><

13,7 mm

8,1 mm

><

><

19,2 mm

8,1 mm

><

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 34: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

34

Range of LockBolt®

Wide clamping rangeThey offer a high resistance to vibrationsOne stem and one collar cover a wide variety of applicationsThe break of the riveting stem is always flush to the collar

Magna-Grip® - Steel

Stem : Steel | Head : Truss

For values of the category F, consult us.

3,0

3,6

4,3

6,6 - 6,71,6 - 15,9

13,3 9,8 5,36,46,22 - 6,32 15,1

MGPT-R8-10GMGC-R8U MGCS-R8U MGCW-R8U

50,87,9 - 31,8 MGPT-R8-20G65,9

8,2 - 8,33,2 - 19,1

20,5 13,3 9,67,97,80 - 7,90 20,4

MGPT-R10-12GMGC-R10U - -

60,315,9 - 34,9 MGPT-R10-22G73,0

9,8 - 9,93,2 - 22,2

28,9 18,7 14,29,59,37 - 9,53 23,6

MGPT-R12-14GMGC-R12U - -

74,620,6 - 41,3 MGPT-R12-26G89,8

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Clampload

kNkNmin

>

>

>< >

<

>< > <k

(mm)

References of the collar

Standard Medium Wide

><

Standard Medium Wide

MGC-R8U MGC-R10U

MGC-R12U

13,2 mm

9,9 mm

><

><

16,4 mm

11,5 mm

><

MGCW-R8U

><

25,5 mm

11,9 mm

><

MGCS-R8U

><

16,3 mm

11,9 mm

><

><

19,6 mm

13,2 mm

><

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 35: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

35

Wide clamping rangeThey offer a high resistance to vibrationsOne stem and one collar cover a wide variety of applicationsThe break of the riveting stem is always flush to the collar

Magna-Grip® - Aluminium

Stem : Aluminium | Head : Truss

For values of the category F, consult us.

3,0

3,6

4,3

6,6 - 6,71,6 - 15,9

7,2 5,3 4,26,46,22 - 6,32 15,1

MGPT-E8-10MGC-F8 MGCS-F8 MGCW-F8

50,87,9 - 31,8 MGPT-E8-2065,9

8,2 - 8,33,2 - 19,1

11,1 9,8 7,17,97,80 - 7,90 20,4

MGPT-E10-12MGC-F10 - -

60,315,9 - 34,9 MGPT-E10-2273,0

9,8 - 9,93,2 - 22,2

17,8 13,3 10,79,59,37 - 9,53 23,6

MGPT-E12-14MGC-F12 - -

74,620,6 - 41,3 MGPT-E12-2689,8

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Clampload

kNkNmin

>

>

>< >

<

>< > <k

(mm)

References of the collar

Standard Medium Wide

><

Standard Medium Wide

MGC-F8 MGC-F10

MGC-F12

13,2 mm

9,9 mm

><

><

16,4 mm

11,3 mm

><

MGCW-F8

><

25,5 mm

11,7 mm

><

MGCS-F8

><

16,3 mm

11,9 mm

><

><

19,6 mm

13,2 mm

><

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 36: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

3636

Range of LockBolt®

6,6 - 6,71,6 - 15,9

13,3 9,8 5,3

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Clampload

kNkNmin

>

>

>< >

<

><

6,46,22 - 6,32 24,9 4,1

MGP30-R8-10GMGC-R8U MGCS-R8U MGCW-R8U

50,815,9 - 38,1 MGP30-R8-24G72,3

9,915,9 - 38,1

28,9 18,7 14,29,59,37 - 9,53 31,9 5,4

MGP30-R12-24GMGC-R12U - -

87,128,6 - 50,8 MGP30-R12-32G99,8

Wide clamping rangeThey offer a high resistance to vibrationsOne stem and one collar cover a wide variety of applicationsThe break of the riveting stem is always flush to the collar

Magna-Grip® - Steel

Stem : Steel | Head : Broad Truss

> <k

(mm)

For values of the category F, consult us.

References of the collar

Standard Medium Wide

><

Standard Medium Wide

MGC-R8U MGC-R12U

13,2 mm

9,9 mm

><

><

19,6 mm

13,2 mm

><

MGCW-R8U

><

25,5 mm

11,9 mm

><

MGCS-R8U

><

16,3 mm

11,9 mm

><

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 37: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

3737

Wide clamping rangeThey offer a high resistance to vibrationsOne stem and one collar cover a wide variety of applicationsThe break of the riveting stem is always flush to the collar

Magna-Grip® - Aluminium

6,6 - 6,71,6 - 15,9

7,2 5,3 4,2

Ø(mm)

d1(mm)

l(mm)

d2(mm)

min - max(mm)

kNmin

Clampload

kNkNmin

>

>

>< >

<

><

6,46,22 - 6,32 27,1 4,6

MGP30-E8-10MGC-F8 MGCS-F8 MGCW-F8

50,815,9 - 38,1 MGP30-E8-2472,3

9,915,9 - 38,1

17,8 13,3 10,79,59,37 - 9,53 31,9 5,4

MGP30-E12-24MGC-F12 - -

87,128,6 - 50,8 MGP30-E12-3299,8

> <k

(mm)

For values of the category F, consult us.

References of the collar

Standard Medium Large

Stem : Aluminium | Head : Broad Truss

><

Standard Medium Wide

MGC-F8 MGC-F12

13,2 mm

9,9 mm

><

><

19,6 mm

13,2 mm

><

MGCW-F8

><

25,5 mm

11,7 mm

><

MGCS-F8

><

16,3 mm

11,9 mm

><

d1 = Diameter - I = Length - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 38: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

3838

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® R Lockbolt - Steel

Stem : Steel | Head : Brazier

5,0 - 5,2 7,3 7,7 4,6

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

4,84,85 - 4,95 9,9 3,2

1,6 - 4,83,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

0,4 - 3,62,0 - 5,23,6 - 6,85,2 - 8,46,8 - 9,98,4 - 11,59,9 - 13,111,5 - 14,713,1 - 16,314,7 - 17,916,3 - 19,517,9 - 21,119,5 - 22,621,1 - 24,222,6 - 25,824,2 - 27,425,8 - 29,027,4 - 30,629,0 - 32,230,6 - 33,832,2 - 35,333,8 - 36,935,3 - 38,536,9 - 40,138,5 - 41,740,1 - 43,341,7 - 44,943,3 - 46,544,9 - 48,0

48,0 - 51,246,5 - 49,6

C6LB-R6-2GC6LB-R6-3GC6LB-R6-4GC6LB-R6-5GC6LB-R6-6GC6LB-R6-7GC6LB-R6-8GC6LB-R6-9GC6LB-R6-10GC6LB-R6-11GC6LB-R6-12GC6LB-R6-13GC6LB-R6-14GC6LB-R6-15GC6LB-R6-16GC6LB-R6-17GC6LB-R6-18GC6LB-R6-19GC6LB-R6-20GC6LB-R6-21GC6LB-R6-22GC6LB-R6-23GC6LB-R6-24GC6LB-R6-25GC6LB-R6-26GC6LB-R6-27GC6LB-R6-28GC6LB-R6-29GC6LB-R6-30GC6LB-R6-31GC6LB-R6-32G

10,612,213,715,316,918,520,121,723,324,926,428,029,631,232,834,436,037,639,140,742,343,945,547,148,750,351,853,455,0

58,256,6

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-R6G

Flanged3LC-2R6G

><

l3(mm)

39,140,742,343,945,447,048,650,251,853,455,056,658,159,761,362,964,566,167,769,370,872,474,075,677,278,880,482,083,5

86,785,1

><

Standard

2LC-R6G 8,1 mm

6,2 mm

><

><

Flanged

3LC-2R6G 10,0 mm

7,4 mm

><

The articles codes in bluecorrespond to the core range(most commonly used references)

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 39: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

3939

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® R Lockbolt - Steel

Stem : Steel | Head : Brazier

6,6 - 6,8 13,3 13,6 8,0

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

6,46,45 - 6,58 13,2 3,9

1,6 - 4,83,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

0,0 - 3,21,6 - 4,83,2 - 6,34,8 - 7,96,3 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,017,5 - 20,619,0 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,730,2 - 33,331,7 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,442,9 - 46,044,4 - 47,6

47,6 - 50,846 - 49,2

C6LB-R8-2GC6LB-R8-3GC6LB-R8-4GC6LB-R8-5GC6LB-R8-6GC6LB-R8-7GC6LB-R8-8GC6LB-R8-9GC6LB-R8-10GC6LB-R8-11GC6LB-R8-12GC6LB-R8-13GC6LB-R8-14GC6LB-R8-15GC6LB-R8-16GC6LB-R8-17GC6LB-R8-18GC6LB-R8-19GC6LB-R8-20GC6LB-R8-21GC6LB-R8-22GC6LB-R8-23GC6LB-R8-24GC6LB-R8-25GC6LB-R8-26GC6LB-R8-27GC6LB-R8-28GC6LB-R8-29GC6LB-R8-30GC6LB-R8-31GC6LB-R8-32G

12,914,516,117,619,220,822,424,025,627,228,830,331,933,535,136,738,339,941,543,044,646,247,849,451,052,654,255,757,3

60,558,9

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-R8G

Flanged3LC-2R8G

><

l3(mm)

42,043,645,246,848,450,051,653,254,756,357,959,561,162,764,365,967,469,070,672,273,875,477,078,680,181,783,384,986,5

89,788,1

><

Standard

2LC-R8G 10,6 mm

8,1 mm

><

><

Flanged

3LC-2R8G 13,2 mm

9,6 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 40: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

40

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® R Lockbolt - Steel

Stem : Steel | Head : Brazier

8,2 - 8,3 20,5 21,0 12,5

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

7,98,05 - 8,18 16,5 5,1

51,955,158,361,564,667,871,074,277,380,583,786,990,093,296,4

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

1,2 - 7,54,4 - 10,77,5 - 13,910,7 - 17,113,9 - 20,217,1 - 23,420,2 - 26,623,4 - 29,826,6 - 32,929,8 - 36,132,9 - 39,336,1 - 42,539,3 - 45,642,5 - 48,845,6 - 52,0

C6LB-R10-4GC6LB-R10-6GC6LB-R10-8GC6LB-R10-10GC6LB-R10-12GC6LB-R10-14GC6LB-R10-16GC6LB-R10-18GC6LB-R10-20GC6LB-R10-22GC6LB-R10-24GC6LB-R10-26GC6LB-R10-28G

C6LB-R10-32GC6LB-R10-30G

19,722,926,129,232,435,638,841,945,148,351,554,657,861,064,2

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-R10G

Flanged3LC-2R10G

><

l3(mm)

><

Standard

2LC-R10G 12,8 mm

9,5 mm

><

><

Flanged

3LC-2R10G 16,4 mm

10,8 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 41: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

41

9,8 - 9,9 28,9 30,4 17,9

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

9,59,65 - 9,78 19,8 6,3

57,360,563,766,870,073,276,479,582,785,989,192,295,498,6101,8

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

0,8 - 7,14,0 - 10,37,1 - 13,510,3 - 16,713,5 - 19,816,7 - 23,019,8 - 26,223,0 - 29,426,2 - 32,529,4 - 35,732,5 - 38,935,7 - 42,138,9 - 45,242,1 - 48,445,2 - 51,6

C6LB-R12-4GC6LB-R12-6GC6LB-R12-8GC6LB-R12-10GC6LB-R12-12GC6LB-R12-14GC6LB-R12-16GC6LB-R12-18GC6LB-R12-20GC6LB-R12-22GC6LB-R12-24GC6LB-R12-26GC6LB-R12-28G

C6LB-R12-32GC6LB-R12-30G

21,724,828,031,234,437,540,743,947,150,253,456,659,862,966,1

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-R12G

Flanged3LC-2R12G

><

l3(mm)

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® R Lockbolt - Steel

Stem : Steel | Head : Brazier

><

Standard

2LC-R12G 15,4 mm

11,9 mm

><

><

Flanged

3LC-2R12G 19,7 mm

13,5 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 42: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

42

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® U Lockbolt - Stainless steel

Stem : Stainless steel | Head : Brazier

5,0 - 5,2 6,5 8,9 4,6

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

4,84,85 - 4,95 9,9 3,2

1,6 - 4,83,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

0,4 - 3,62,0 - 5,23,6 - 6,85,2 - 8,46,8 - 9,98,4 - 11,59,9 - 13,111,5 - 14,713,1 - 16,314,7 - 17,916,3 - 19,517,9 - 21,119,5 - 22,621,1 - 24,222,6 - 25,824,2 - 27,425,8 - 29,027,4 - 30,629,0 - 32,230,6 - 33,832,2 - 35,333,8 - 36,935,3 - 38,536,9 - 40,138,5 - 41,740,1 - 43,341,7 - 44,943,3 - 46,544,9 - 48,0

48,0 - 51,246,5 - 49,6

C6LB-U6-2C6LB-U6-3C6LB-U6-4C6LB-U6-5C6LB-U6-6C6LB-U6-7C6LB-U6-8C6LB-U6-9C6LB-U6-10C6LB-U6-11C6LB-U6-12C6LB-U6-13C6LB-U6-14C6LB-U6-15C6LB-U6-16C6LB-U6-17C6LB-U6-18C6LB-U6-19C6LB-U6-20C6LB-U6-21C6LB-U6-22C6LB-U6-23C6LB-U6-24C6LB-U6-25C6LB-U6-26C6LB-U6-27C6LB-U6-28C6LB-U6-29C6LB-U6-30C6LB-U6-31C6LB-U6-32

10,612,213,715,316,918,520,121,723,324,926,428,029,631,232,834,436,037,639,140,742,343,945,547,148,750,351,853,455,0

58,256,6

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-2CU6

Flanged3LC-2CU6

><

l3(mm)

39,140,742,343,945,447,048,650,251,853,455,056,658,159,761,362,964,566,167,769,370,872,474,075,677,278,880,482,083,5

86,785,1

><

Standard

2LC-2CU6 8,1 mm

6,2 mm

><

><

Flanged

3LC-2CU6 10,0 mm

7,4 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 43: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

43

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® U Lockbolt - Stainless steel

Stem : Stainless steel | Head : Brazier

6,6 - 6,8 16,7 15,8 8,0

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

6,46,45 - 6,58 13,2 3,9

1,6 - 4,83,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

0,0 - 3,21,6 - 4,83,2 - 6,34,8 - 7,96,3 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,017,5 - 20,619,0 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,730,2 - 33,331,7 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,442,9 - 46,044,4 - 47,6

47,6 - 50,846 - 49,2

C6LB-U8-2C6LB-U8-3C6LB-U8-4C6LB-U8-5C6LB-U8-6C6LB-U8-7C6LB-U8-8C6LB-U8-9C6LB-U8-10C6LB-U8-11C6LB-U8-12C6LB-U8-13C6LB-U8-14C6LB-U8-15C6LB-U8-16C6LB-U8-17C6LB-U8-18C6LB-U8-19C6LB-U8-20C6LB-U8-21C6LB-U8-22C6LB-U8-23C6LB-U8-24C6LB-U8-25C6LB-U8-26C6LB-U8-27C6LB-U8-28C6LB-U8-29C6LB-U8-30C6LB-U8-31C6LB-U8-32

12,914,516,117,619,220,822,424,025,627,228,830,331,933,535,136,738,339,941,543,044,646,247,849,451,052,654,255,757,3

60,558,9

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-2CU8

Flanged3LC-2CU8

><

l3(mm)

42,043,645,246,848,450,051,653,254,756,357,959,561,162,764,365,967,469,070,672,273,875,477,078,680,181,783,384,986,5

89,788,1

><

Standard

2LC-2CU8 10,6 mm

8,1 mm

><

><

Flanged

3LC-2CU8 13,2 mm

9,6 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 44: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

44

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® U Lockbolt - Stainless steel

Stem : Stainless steel | Head : Brazier

8,2 - 8,3 18,9 24,6 12,5

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

7,98,05 - 8,18 16,5 5,1

51,955,158,361,564,667,871,074,277,380,583,786,990,093,296,4

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

1,2 - 7,54,4 - 10,77,5 - 13,910,7 - 17,113,9 - 20,217,1 - 23,420,2 - 26,623,4 - 29,826,6 - 32,929,8 - 36,132,9 - 39,336,1 - 42,539,3 - 45,642,5 - 48,845,6 - 52,0

C6LB-U10-4C6LB-U10-6C6LB-U10-8C6LB-U10-10C6LB-U10-12C6LB-U10-14C6LB-U10-16C6LB-U10-18C6LB-U10-20C6LB-U10-22C6LB-U10-24C6LB-U10-26C6LB-U10-28

C6LB-U10-32C6LB-U10-30

19,722,926,129,232,435,638,841,945,148,351,554,657,861,064,2

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-2CU10

Flanged3LC-2CU10

><

l3(mm)

><

Standard

2LC-2CU10 12,8 mm

9,5 mm

><

><

Flanged

3LC-2CU10 16,4 mm

10,8 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 45: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

45

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® U Lockbolt - Stainless steel

Stem : Stainless steel | Head : Brazier

9,8 - 9,9 27,1 35,4 17,9

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

9,59,65 - 9,78 19,8 6,3

57,360,563,766,870,073,276,479,582,785,989,192,295,498,6101,8

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

0,8 - 7,14,0 - 10,37,1 - 13,510,3 - 16,713,5 - 19,816,7 - 23,019,8 - 26,223,0 - 29,426,2 - 32,529,4 - 35,732,5 - 38,935,7 - 42,138,9 - 45,242,1 - 48,445,2 - 51,6

C6LB-U12-4C6LB-U12-6C6LB-U12-8C6LB-U12-10C6LB-U12-12C6LB-U12-14C6LB-U12-16C6LB-U12-18C6LB-U12-20C6LB-U12-22C6LB-U12-24C6LB-U12-26C6LB-U12-28

C6LB-U12-32C6LB-U12-30

21,724,828,031,234,437,540,743,947,150,253,456,659,862,966,1

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-2CU12

Flanged3LC-2CU12

><

l3(mm)

><

Standard

2LC-2CU12 15,4 mm

11,9 mm

><

><

Flanged

3LC-2CU12 19,7 mm

13,5 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 46: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

46

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: Enables installation into non metallic materialsThe stems are also available in Aluminium 2024 Ref: C6LB-C6References of the corresponding collar: standard collar 2LC-F6, Flanged collar 3LC-F6For the values of clamping force and tensile/shear strength in Aluminium 2024, please consult-us

C6L® F Lockbolt - Aluminium 6061

Stem : Aluminium 6061 | Head : Brazier

5,0 - 5,2 2,4 3,4 1,6

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

4,84,85 - 4,95 9,9 3,2

1,6 - 4,83,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

0,4 - 3,62,0 - 5,23,6 - 6,85,2 - 8,46,8 - 9,98,4 - 11,59,9 - 13,111,5 - 14,713,1 - 16,314,7 - 17,916,3 - 19,517,9 - 21,119,5 - 22,621,1 - 24,222,6 - 25,824,2 - 27,425,8 - 29,027,4 - 30,629,0 - 32,230,6 - 33,832,2 - 35,333,8 - 36,935,3 - 38,536,9 - 40,138,5 - 41,740,1 - 43,341,7 - 44,943,3 - 46,544,9 - 48,0

48,0 - 51,246,5 - 49,6

C6LB-F6-2C6LB-F6-3C6LB-F6-4C6LB-F6-5C6LB-F6-6C6LB-F6-7C6LB-F6-8C6LB-F6-9C6LB-F6-10C6LB-F6-11C6LB-F6-12C6LB-F6-13C6LB-F6-14C6LB-F6-15C6LB-F6-16C6LB-F6-17C6LB-F6-18C6LB-F6-19C6LB-F6-20C6LB-F6-21C6LB-F6-22C6LB-F6-23C6LB-F6-24C6LB-F6-25C6LB-F6-26C6LB-F6-27C6LB-F6-28C6LB-F6-29C6LB-F6-30C6LB-F6-31C6LB-F6-32

10,612,213,715,316,918,520,121,723,324,926,428,029,631,232,834,436,037,639,140,742,343,945,547,148,750,351,853,455,0

58,256,6

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

StandardLC-I6

Flanged3LC-I6

><

l3(mm)

39,140,742,343,945,447,048,650,251,853,455,056,658,159,761,362,964,566,167,769,370,872,474,075,677,278,880,482,083,5

86,785,1

><

Standard

LC-I6 8,1 mm

6,2 mm

><

><

Flanged

3LC-I6 10,0 mm

7,4 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 47: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

47

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: Enables installation into non metallic materialsThe stems are also available in Aluminium 2024 Ref: C6LB-C8References of the corresponding collar: standard collar 2LC-F8, Flanged collar 3LC-F8For the values of clamping force and tensile/shear strength in Aluminium 2024, please consult-us

C6L® F Lockbolt - Aluminium 6061

Stem : Aluminium 6061 | Head : Brazier

6,6 - 6,8 4,3 6,1 2,8

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

6,46,45 - 6,58 13,2 3,9

1,6 - 4,83,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

0,0 - 3,21,6 - 4,83,2 - 6,34,8 - 7,96,3 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,017,5 - 20,619,0 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,730,2 - 33,331,7 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,442,9 - 46,044,4 - 47,6

47,6 - 50,846 - 49,2

C6LB-F8-2C6LB-F8-3C6LB-F8-4C6LB-F8-5C6LB-F8-6C6LB-F8-7C6LB-F8-8C6LB-F8-9C6LB-F8-10C6LB-F8-11C6LB-F8-12C6LB-F8-13C6LB-F8-14C6LB-F8-15C6LB-F8-16C6LB-F8-17C6LB-F8-18C6LB-F8-19C6LB-F8-20C6LB-F8-21C6LB-F8-22C6LB-F8-23C6LB-F8-24C6LB-F8-25C6LB-F8-26C6LB-F8-27C6LB-F8-28C6LB-F8-29C6LB-F8-30C6LB-F8-31C6LB-F8-32

12,914,516,117,619,220,822,424,025,627,228,830,331,933,535,136,738,339,941,543,044,646,247,849,451,052,654,255,757,3

60,558,9

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

StandardLC-I8

Flanged3LC-I8

><

l3(mm)

42,043,645,246,848,450,051,653,254,756,357,959,561,162,764,365,967,469,070,672,273,875,477,078,680,181,783,384,986,5

89,788,1

><

Standard

LC-I8 10,6 mm

8,1 mm

><

><

Flanged

3LC-I8 13,2 mm

9,6 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 48: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

48

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: Enables installation into non metallic materialsThe stems are also available in Aluminium 2024 Ref: C6LB-C10References of the corresponding collar: standard collar 2LC-F10, Flanged collar 3LC-F10For the values of clamping force and tensile/shear strength in Aluminium 2024, please consult-us

C6L® F Lockbolt - Aluminium 6061

Stem : Aluminium 6061 | Head : Brazier

8,2 - 8,3 6,9 9,5 4,3

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Effortde

serrage

kNkNmin

><

><

7,98,05 - 8,18 16,5 5,1

51,955,158,361,564,667,871,074,277,380,583,786,990,093,296,4

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

1,2 - 7,54,4 - 10,77,5 - 13,910,7 - 17,113,9 - 20,217,1 - 23,420,2 - 26,623,4 - 29,826,6 - 32,929,8 - 36,132,9 - 39,336,1 - 42,539,3 - 45,642,5 - 48,845,6 - 52,0

C6LB-F10-4C6LB-F10-6C6LB-F10-8C6LB-F10-10C6LB-F10-12C6LB-F10-14C6LB-F10-16C6LB-F10-18C6LB-F10-20C6LB-F10-22C6LB-F10-24C6LB-F10-26C6LB-F10-28

C6LB-F10-32C6LB-F10-30

19,722,926,129,232,435,638,841,945,148,351,554,657,861,064,2

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

StandardLC-I10

Flanged3LC-I10

><

l3(mm)

><

Standard

LC-I10 12,8 mm

9,5 mm

><

><

Flanged

3LC-I10 16,4 mm

10,8 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 49: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

49

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: Enables installation into non metallic materialsThe stems are also available in Aluminium 2024 Ref: C6LB-C12References of the corresponding collar: standard collar 2LC-F12, Flanged collar 3LC-F12For the values of clamping force and tensile/shear strength in Aluminium 2024, please consult-us

C6L® F Lockbolt - Aluminium 6061

Stem : Aluminium 6061 | Head : Brazier

9,9 10,7 13,6 6,1

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

9,59,65 - 9,78 19,8 6,3

57,360,563,766,870,073,276,479,582,785,989,192,295,498,6101,8

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

0,8 - 7,14,0 - 10,37,1 - 13,510,3 - 16,713,5 - 19,816,7 - 23,019,8 - 26,223,0 - 29,426,2 - 32,529,4 - 35,732,5 - 38,935,7 - 42,138,9 - 45,242,1 - 48,445,2 - 51,6

C6LB-F12-4C6LB-F12-6C6LB-F12-8C6LB-F12-10C6LB-F12-12C6LB-F12-14C6LB-F12-16C6LB-F12-18C6LB-F12-20C6LB-F12-22C6LB-F12-24C6LB-F12-26C6LB-F12-28

C6LB-F12-32C6LB-F12-30

21,724,828,031,234,437,540,743,947,150,253,456,659,862,966,1

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

StandardLC-I12

Flanged3LC-I12

><

l3(mm)

><

Standard

LC-I12 15,4 mm

11,9 mm

><

><

Flanged

3LC-I12 19,7 mm

13,5 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 50: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

50

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® 90R Lockbolt - Steel

Stem : Steel | Head : Countersunk

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

Standard2LC-R6G

Flanged3LC-2R6G

><

l3(mm)

5,0 - 5,2 7,3 7,7 4,64,84,85 - 4,95 9,1 2,2

3,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

2,0 - 5,23,6 - 6,85,2 - 8,46,8 - 9,98,4 - 11,59,9 - 13,111,5 - 14,713,1 - 16,314,7 - 17,916,3 - 19,517,9 - 21,119,5 - 22,621,1 - 24,222,6 - 25,824,2 - 27,425,8 - 29,027,4 - 30,629,0 - 32,230,6 - 33,832,2 - 35,333,8 - 36,935,3 - 38,536,9 - 40,138,5 - 41,740,1 - 43,341,7 - 44,943,3 - 46,544,9 - 48,0

48,0 - 51,246,5 - 49,6

C6L90-R6-3GC6L90-R6-4GC6L90-R6-5GC6L90-R6-6GC6L90-R6-7GC6L90-R6-8GC6L90-R6-9GC6L90-R6-10GC6L90-R6-11GC6L90-R6-12GC6L90-R6-13GC6L90-R6-14GC6L90-R6-15GC6L90-R6-16GC6L90-R6-17GC6L90-R6-18GC6L90-R6-19GC6L90-R6-20GC6L90-R6-21GC6L90-R6-22GC6L90-R6-23GC6L90-R6-24GC6L90-R6-25GC6L90-R6-26GC6L90-R6-27GC6L90-R6-28GC6L90-R6-29GC6L90-R6-30GC6L90-R6-31GC6L90-R6-32G

12,213,715,316,918,520,121,723,324,926,428,029,631,232,834,436,037,639,140,742,343,945,547,148,750,351,853,455,0

58,256,6

3,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

39,941,543,144,746,347,949,551,052,654,255,857,459,060,662,263,765,366,968,570,171,773,374,976,478,079,681,282,8

86,084,4

><

Standard

2LC-R6G 8,1 mm

6,2 mm

><

><

Flanged

3LC-2R6G 10,0 mm

7,4 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 51: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

51

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® 90R Lockbolt - Steel

Stem : Steel | Head : Countersunk

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

Standard2LC-R8G

Flanged3LC-2R8G

><

l3(mm)

6,6 - 6,8 13,3 13,6 8,06,46,45 - 6,58 12,1 2,9

3,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

1,6 - 4,83,2 - 6,34,8 - 7,96,3 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,017,5 - 20,619,0 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,730,2 - 33,331,7 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,442,9 - 46,044,4 - 47,6

47,6 - 50,846 - 49,2

C6L90-R8-3GC6L90-R8-4GC6L90-R8-5GC6L90-R8-6GC6L90-R8-7GC6L90-R8-8GC6L90-R8-9GC6L90-R8-10GC6L90-R8-11GC6L90-R8-12GC6L90-R8-13GC6L90-R8-14GC6L90-R8-15GC6L90-R8-16GC6L90-R8-17GC6L90-R8-18GC6L90-R8-19GC6L90-R8-20GC6L90-R8-21GC6L90-R8-22GC6L90-R8-23GC6L90-R8-24GC6L90-R8-25GC6L90-R8-26GC6L90-R8-27GC6L90-R8-28GC6L90-R8-29GC6L90-R8-30GC6L90-R8-31GC6L90-R8-32G

14,516,117,619,220,822,424,025,627,228,830,331,933,535,136,738,339,941,543,044,646,247,849,451,052,654,255,757,3

60,558,9

3,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

43,144,746,347,949,551,052,654,255,857,459,060,662,263,765,366,968,570,171,773,374,976,478,079,681,282,884,486,0

89,187,6

><

Standard

2LC-R8G 10,6 mm

8,1 mm

><

><

Flanged

3LC-2R8G 13,2 mm

9,6 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 52: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

52

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® 90R Lockbolt - Steel

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

Standard2LC-R10G

Flanged3LC-2R10G

><

l3(mm)

Stem : Steel | Head : Countersunk

8,2 - 8,3 20,5 21,0 12,57,98,05 - 8,18 15,1 3,6

53,055,058,261,464,667,770,974,177,380,483,686,890,093,196,3

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

1,2 - 7,54,4 - 10,77,5 - 13,910,7 - 17,113,9 - 20,217,1 - 23,420,2 - 26,623,4 - 29,826,6 - 32,929,8 - 36,132,9 - 39,336,1 - 42,539,3 - 45,642,5 - 48,845,6 - 52,0

C6L90-R10-4GC6L90-R10-6GC6L90-R10-8GC6L90-R10-10GC6L90-R10-12GC6L90-R10-14GC6L90-R10-16GC6L90-R10-18GC6L90-R10-20GC6L90-R10-22GC6L90-R10-24GC6L90-R10-26GC6L90-R10-28G

C6L90-R10-32GC6L90-R10-30G

20,924,127,230,433,636,839,943,146,349,552,655,859,062,264,2

4,36,49,512,715,919,122,225,428,631,834,938,141,344,547,6

><

Standard

2LC-R10G 12,8 mm

9,5 mm

><

><

Flanged

3LC-2R10G 16,4 mm

10,8 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 53: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

53

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® 90R Lockbolt - Steel

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

Standard2LC-R12G

Flanged3LC-2R12G

><

l3(mm)

Stem : Steel | Head : Countersunk

9,9 28,9 30,4 17,99,59,65 - 9,78 18,1 4,3

60,663,866,970,173,376,579,682,886,089,292,395,598,7101,9

6,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

4,0 - 10,37,1 - 13,510,3 - 16,713,5 - 19,816,7 - 23,019,8 - 26,223,0 - 29,426,2 - 32,529,4 - 35,732,5 - 38,935,7 - 42,138,9 - 45,242,1 - 48,445,2 - 51,6

C6L90-R12-6GC6L90-R12-8GC6L90-R12-10GC6L90-R12-12GC6L90-R12-14GC6L90-R12-16GC6L90-R12-18GC6L90-R12-20GC6L90-R12-22GC6L90-R12-24GC6L90-R12-26GC6L90-R12-28G

C6L90-R12-32GC6L90-R12-30G

24,828,031,234,437,540,743,947,150,253,456,659,862,966,1

6,49,512,715,919,122,225,428,631,834,938,141,344,547,6

><

Standard

2LC-R12G 15,4 mm

11,9 mm

><

><

Flanged

3LC-2R12G 19,7 mm

13,5 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 54: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

54

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: Enables installation into non metallic materialsThe stems are also available in Steel Ref: C6L90-R6References of the corresponding collar: standard collar 2LC-R6G, Flanged collar 3LC-2R6GFor the values of clamping force and tensile/shear strength in Steel, please consult-us

C6L® 90U Lockbolt - Stainless steel

Stem : Stainless steel | Head : Countersunk

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

Standard2LC-2CU6

Flanged3LC-2CU6

><

l3(mm)

5,0 - 5,2 6,5 8,9 4,64,84,85 - 4,95 9,1 2,2

3,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

2,0 - 5,23,6 - 6,85,2 - 8,46,8 - 9,98,4 - 11,59,9 - 13,111,5 - 14,713,1 - 16,314,7 - 17,916,3 - 19,517,9 - 21,119,5 - 22,621,1 - 24,222,6 - 25,824,2 - 27,425,8 - 29,027,4 - 30,629,0 - 32,230,6 - 33,832,2 - 35,333,8 - 36,935,3 - 38,536,9 - 40,138,5 - 41,740,1 - 43,341,7 - 44,943,3 - 46,544,9 - 48,0

48,0 - 51,246,5 - 49,6

C6L90-U6-3C6L90-U6-4C6L90-U6-5C6L90-U6-6C6L90-U6-7C6L90-U6-8C6L90-U6-9C6L90-U6-10C6L90-U6-11C6L90-U6-12C6L90-U6-13C6L90-U6-14C6L90-U6-15C6L90-U6-16C6L90-U6-17C6L90-U6-18C6L90-U6-19C6L90-U6-20C6L90-U6-21C6L90-U6-22C6L90-U6-23C6L90-U6-24C6L90-U6-25C6L90-U6-26C6L90-U6-27C6L90-U6-28C6L90-U6-29C6L90-U6-30C6L90-U6-31C6L90-U6-32

12,213,715,316,918,520,121,723,324,926,428,029,631,232,834,436,037,639,140,742,343,945,547,148,750,351,853,455,0

58,256,6

3,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

39,941,543,144,746,347,949,551,052,654,255,857,459,060,662,263,765,366,968,570,171,773,374,976,478,079,681,282,8

86,084,4

><

Standard

2LC-2CU6 8,1 mm

6,2 mm

><

><

Flanged

3LC-2CU6 10,0 mm

7,4 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 55: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

55

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: Enables installation into non metallic materialsThe stems are also available in Steel Ref: C6L90-R8References of the corresponding collar: standard collar 2LC-R8G, Flanged collar 3LC-2R8GFor the values of clamping force and tensile/shear strength in Steel, please consult-us

C6L® 90U Lockbolt - Stainless steel

Stem : Stainless steel | Head : Countersunk

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

Standard2LC-2CU8

Flanged3LC-2CU8

><

l3(mm)

6,6 - 6,8 16,7 15,8 8,06,46,45 - 6,58 12,1 2,9

3,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

1,6 - 4,83,2 - 6,34,8 - 7,96,3 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,017,5 - 20,619,0 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,730,2 - 33,331,7 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,442,9 - 46,044,4 - 47,6

47,6 - 50,846 - 49,2

C6L90-U8-3C6L90-U8-4C6L90-U8-5C6L90-U8-6C6L90-U8-7C6L90-U8-8C6L90-U8-9C6L90-U8-10C6L90-U8-11C6L90-U8-12C6L90-U8-13C6L90-U8-14C6L90-U8-15C6L90-U8-16C6L90-U8-17C6L90-U8-18C6L90-U8-19C6L90-U8-20C6L90-U8-21C6L90-U8-22C6L90-U8-23C6L90-U8-24C6L90-U8-25C6L90-U8-26C6L90-U8-27C6L90-U8-28C6L90-U8-29C6L90-U8-30C6L90-U8-31C6L90-U8-32

14,516,117,619,220,822,424,025,627,228,830,331,933,535,136,738,339,941,543,044,646,247,849,451,052,654,255,757,3

60,558,9

3,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

43,144,746,347,949,551,052,654,255,857,459,060,662,263,765,366,968,570,171,773,374,976,478,079,681,282,884,486,0

89,187,6

><

Standard

2LC-2CU8 10,6 mm

8,1 mm

><

><

Flanged

3LC-2CU8 13,2 mm

9,6 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 56: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

Standard2LC-2CU10

Flanged3LC-2CU10

><

l3(mm)

56

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: Enables installation into non metallic materialsThe stems are also available in Steel Ref: C6L90-R10References of the corresponding collar: standard collar 2LC-R10G, Flanged collar 3LC-2R10GFor the values of clamping force and tensile/shear strength in Steel, please consult-us

C6L® 90U Lockbolt - Stainless steel

Stem : Stainless steel | Head : Countersunk

8,2 - 8,3 18,9 24,6 12,57,98,05 - 8,18 15,1 3,6

53,055,058,261,464,667,770,974,177,380,483,686,890,093,196,3

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

1,2 - 7,54,4 - 10,77,5 - 13,910,7 - 17,113,9 - 20,217,1 - 23,420,2 - 26,623,4 - 29,826,6 - 32,929,8 - 36,132,9 - 39,336,1 - 42,539,3 - 45,642,5 - 48,845,6 - 52,0

C6L90-U10-4C6L90-U10-6C6L90-U10-8C6L90-U10-10C6L90-U10-12C6L90-U10-14C6L90-U10-16C6L90-U10-18C6L90-U10-20C6L90-U10-22C6L90-U10-24C6L90-U10-26C6L90-U10-28

C6L90-U10-32C6L90-U10-30

20,924,127,230,433,636,839,943,146,349,552,655,859,062,264,2

4,36,49,512,715,919,122,225,428,631,834,938,141,344,547,6

><

Standard

2LC-2CU10 12,8 mm

9,5 mm

><

><

Flanged

3LC-2CU10 16,4 mm

10,8 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 57: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

Standard2LC-2CU12

Flanged3LC-2CU12

><

l3(mm)

57

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: Enables installation into non metallic materialsThe stems are also available in Steel Ref: C6L90-R12References of the corresponding collar: standard collar 2LC-R12G, Flanged collar 3LC-2R12GFor the values of clamping force and tensile/shear strength in Steel, please consult-us

C6L® 90U Lockbolt - Stainless steel

Stem : Stainless steel | Head : Countersunk

9,8 - 9,9 27,1 35,4 17,99,59,65 - 9,78 18,1 4,3

60,663,866,970,173,376,579,682,886,089,292,395,598,7101,9

6,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

4,0 - 10,37,1 - 13,510,3 - 16,713,5 - 19,816,7 - 23,019,8 - 26,223,0 - 29,426,2 - 32,529,4 - 35,732,5 - 38,935,7 - 42,138,9 - 45,242,1 - 48,445,2 - 51,6

C6L90-U12-6C6L90-U12-8C6L90-U12-10C6L90-U12-12C6L90-U12-14C6L90-U12-16C6L90-U12-18C6L90-U12-20C6L90-U12-22C6L90-U12-24C6L90-U12-26C6L90-U12-28

C6L90-U12-32C6L90-U12-30

24,828,031,234,437,540,743,947,150,253,456,659,862,966,1

6,49,512,715,919,122,225,428,631,834,938,141,344,547,6

><

Standard

2LC-2CU12 15,4 mm

11,9 mm

><

><

Flanged

3LC-2CU12 19,7 mm

13,5 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 58: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

58

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® 90C Lockbolt - Aluminium

Stem : Aluminium | Head : Countersunk

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

Standard2LC-F6

Flanged3LC-F6

><

l3(mm)

5,0 - 5,2 4,4 4,7 2,44,84,85 - 4,95 9,1 2,2

3,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

2,0 - 5,23,6 - 6,85,2 - 8,46,8 - 9,98,4 - 11,59,9 - 13,111,5 - 14,713,1 - 16,314,7 - 17,916,3 - 19,517,9 - 21,119,5 - 22,621,1 - 24,222,6 - 25,824,2 - 27,425,8 - 29,027,4 - 30,629,0 - 32,230,6 - 33,832,2 - 35,333,8 - 36,935,3 - 38,536,9 - 40,138,5 - 41,740,1 - 43,341,7 - 44,943,3 - 46,544,9 - 48,0

48,0 - 51,246,5 - 49,6

C6L90-C6-3C6L90-C6-4C6L90-C6-5C6L90-C6-6C6L90-C6-7C6L90-C6-8C6L90-C6-9C6L90-C6-10C6L90-C6-11C6L90-C6-12C6L90-C6-13C6L90-C6-14C6L90-C6-15C6L90-C6-16C6L90-C6-17C6L90-C6-18C6L90-C6-19C6L90-C6-20C6L90-C6-21C6L90-C6-22C6L90-C6-23C6L90-C6-24C6L90-C6-25C6L90-C6-26C6L90-C6-27C6L90-C6-28C6L90-C6-29C6L90-C6-30C6L90-C6-31C6L90-C6-32

12,213,715,316,918,520,121,723,324,926,428,029,631,232,834,436,037,639,140,742,343,945,547,148,750,351,853,455,0

58,256,6

3,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

39,941,543,144,746,347,949,551,052,654,255,857,459,060,662,263,765,366,968,570,171,773,374,976,478,079,681,282,8

86,084,4

><

Standard

2LC-F6 8,1 mm

6,2 mm

><

><

Flanged

3LC-F6 10,0 mm

7,4 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 59: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

59

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® 90C Lockbolt - Aluminium

Stem : Aluminium | Head : Countersunk

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

Standard2LC-F8

Flanged3LC-F8

><

l3(mm)

6,6 - 6,8 8,0 8,3 4,26,46,45 - 6,58 12,1 2,9

3,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

1,6 - 4,83,2 - 6,34,8 - 7,96,3 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,017,5 - 20,619,0 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,730,2 - 33,331,7 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,442,9 - 46,044,4 - 47,6

47,6 - 50,846 - 49,2

C6L90-C8-3C6L90-C8-4C6L90-C8-5C6L90-C8-6C6L90-C8-7C6L90-C8-8C6L90-C8-9C6L90-C8-10C6L90-C8-11C6L90-C8-12C6L90-C8-13C6L90-C8-14C6L90-C8-15C6L90-C8-16C6L90-C8-17C6L90-C8-18C6L90-C8-19C6L90-C8-20C6L90-C8-21C6L90-C8-22C6L90-C8-23C6L90-C8-24C6L90-C8-25C6L90-C8-26C6L90-C8-27C6L90-C8-28C6L90-C8-29C6L90-C8-30C6L90-C8-31C6L90-C8-32

14,516,117,619,220,822,424,025,627,228,830,331,933,535,136,738,339,941,543,044,646,247,849,451,052,654,255,757,3

60,558,9

3,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

43,144,746,347,949,551,052,654,255,857,459,060,662,263,765,366,968,570,171,773,374,976,478,079,681,282,884,486,0

89,187,6

><

Standard

2LC-F8 10,6 mm

8,1 mm

><

><

Flanged

3LC-F8 13,2 mm

9,6 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 60: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

60

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® 90C Lockbolt - Aluminium

Stem : Aluminium | Head : Countersunk

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

Standard2LC-F10

Flanged3LC-F10

><

l3(mm)

8,2 - 8,3 12,7 13,0 6,77,98,05 - 8,18 15,1 3,6

53,055,058,261,464,667,770,974,177,380,483,686,890,093,196,3

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

1,2 - 7,54,4 - 10,77,5 - 13,910,7 - 17,113,9 - 20,217,1 - 23,420,2 - 26,623,4 - 29,826,6 - 32,929,8 - 36,132,9 - 39,336,1 - 42,539,3 - 45,642,5 - 48,845,6 - 52,0

C6L90-C10-4C6L90-C10-6C6L90-C10-8C6L90-C10-10C6L90-C10-12C6L90-C10-14C6L90-C10-16C6L90-C10-18C6L90-C10-20C6L90-C10-22C6L90-C10-24C6L90-C10-26C6L90-C10-28

C6L90-C10-32C6L90-C10-30

20,924,127,230,433,636,839,943,146,349,552,655,859,062,264,2

4,36,49,512,715,919,122,225,428,631,834,938,141,344,547,6

><

Standard

2LC-F10 12,8 mm

9,5 mm

><

><

Flanged

3LC-F10 16,4 mm

10,8 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 61: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

61

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® 90C Lockbolt - Aluminium

Stem : Aluminium | Head : Countersunk

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

Standard2LC-F12

Flanged3LC-F12

><

l3(mm)

9,8 - 9,9 18,7 18,7 9,89,59,65 - 9,78 18,1 4,3

60,663,866,970,173,376,579,682,886,089,292,395,598,7101,9

6,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

4,0 - 10,37,1 - 13,510,3 - 16,713,5 - 19,816,7 - 23,019,8 - 26,223,0 - 29,426,2 - 32,529,4 - 35,732,5 - 38,935,7 - 42,138,9 - 45,242,1 - 48,445,2 - 51,6

C6L90-C12-6C6L90-C12-8C6L90-C12-10C6L90-C12-12C6L90-C12-14C6L90-C12-16C6L90-C12-18C6L90-C12-20C6L90-C12-22C6L90-C12-24C6L90-C12-26C6L90-C12-28

C6L90-C12-32C6L90-C12-30

24,828,031,234,437,540,743,947,150,253,456,659,862,966,1

6,49,512,715,919,122,225,428,631,834,938,141,344,547,6

><

Standard

2LC-F12 15,4 mm

11,9 mm

><

><

Flanged

3LC-F12 19,7 mm

13,5 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 62: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

62

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® 90F Lockbolt - Aluminium 6061

Stem : Aluminium 6061 | Head : Countersunk

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

StandardLC-I6

Flanged3LC-I6

><

l3(mm)

5,0 - 5,2 2,4 3,4 1,64,84,85 - 4,95 9,1 2,2

3,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

2,0 - 5,23,6 - 6,85,2 - 8,46,8 - 9,98,4 - 11,59,9 - 13,111,5 - 14,713,1 - 16,314,7 - 17,916,3 - 19,517,9 - 21,119,5 - 22,621,1 - 24,222,6 - 25,824,2 - 27,425,8 - 29,027,4 - 30,629,0 - 32,230,6 - 33,832,2 - 35,333,8 - 36,935,3 - 38,536,9 - 40,138,5 - 41,740,1 - 43,341,7 - 44,943,3 - 46,544,9 - 48,0

48,0 - 51,246,5 - 49,6

C6L90-F6-3C6L90-F6-4C6L90-F6-5C6L90-F6-6C6L90-F6-7C6L90-F6-8C6L90-F6-9C6L90-F6-10C6L90-F6-11C6L90-F6-12C6L90-F6-13C6L90-F6-14C6L90-F6-15C6L90-F6-16C6L90-F6-17C6L90-F6-18C6L90-F6-19C6L90-F6-20C6L90-F6-21C6L90-F6-22C6L90-F6-23C6L90-F6-24C6L90-F6-25C6L90-F6-26C6L90-F6-27C6L90-F6-28C6L90-F6-29C6L90-F6-30C6L90-F6-31C6L90-F6-32

12,213,715,316,918,520,121,723,324,926,428,029,631,232,834,436,037,639,140,742,343,945,547,148,750,351,853,455,0

58,256,6

3,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

39,941,543,144,746,347,949,551,052,654,255,857,459,060,662,263,765,366,968,570,171,773,374,976,478,079,681,282,8

86,084,4

><

Standard

LC-I6 8,1 mm

6,2 mm

><

><

Flanged

3LC-I6 10,0 mm

7,4 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 63: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

63

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® 90F Lockbolt - Aluminium 6061

Stem : Aluminium 6061 | Head : Countersunk

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

StandardLC-I8

Flanged3LC-I8

><

l3(mm)

6,6 - 6,8 4,3 6,1 2,86,46,45 - 6,58 12,1 2,9

3,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

1,6 - 4,83,2 - 6,34,8 - 7,96,3 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,017,5 - 20,619,0 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,730,2 - 33,331,7 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,442,9 - 46,044,4 - 47,6

47,6 - 50,846,0 - 49,2

C6L90-F8-3C6L90-F8-4C6L90-F8-5C6L90-F8-6C6L90-F8-7C6L90-F8-8C6L90-F8-9C6L90-F8-10C6L90-F8-11C6L90-F8-12C6L90-F8-13C6L90-F8-14C6L90-F8-15C6L90-F8-16C6L90-F8-17C6L90-F8-18C6L90-F8-19C6L90-F8-20C6L90-F8-21C6L90-F8-22C6L90-F8-23C6L90-F8-24C6L90-F8-25C6L90-F8-26C6L90-F8-27C6L90-F8-28C6L90-F8-29C6L90-F8-30C6L90-F8-31C6L90-F8-32

14,516,117,619,220,822,424,025,627,228,830,331,933,535,136,738,339,941,543,044,646,247,849,451,052,654,255,757,3

60,558,9

3,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

43,144,746,347,949,551,052,654,255,857,459,060,662,263,765,366,968,570,171,773,374,976,478,079,681,282,884,486,0

89,187,6

><

Standard

LC-I8 10,6 mm

8,1 mm

><

><

Flanged

3LC-I8 13,2 mm

9,6 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 64: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

64

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® 90F Lockbolt - Aluminium 6061

Stem : Aluminium 6061 | Head : Countersunk

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

StandardLC-I10

Flanged3LC-I10

><

l3(mm)

8,2 - 8,3 6,9 9,5 4,37,98,05 - 8,18 15,1 3,6

53,055,058,261,464,667,770,974,177,380,483,686,890,093,196,3

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

1,2 - 7,54,4 - 10,77,5 - 13,910,7 - 17,113,9 - 20,217,1 - 23,420,2 - 26,623,4 - 29,826,6 - 32,929,8 - 36,132,9 - 39,336,1 - 42,539,3 - 45,642,5 - 48,845,6 - 52,0

C6L90-F10-4C6L90-F10-6C6L90-F10-8C6L90-F10-10C6L90-F10-12C6L90-F10-14C6L90-F10-16C6L90-F10-18C6L90-F10-20C6L90-F10-22C6L90-F10-24C6L90-F10-26C6L90-F10-28

C6L90-F10-32C6L90-F10-30

20,924,127,230,433,636,839,943,146,349,552,655,859,062,264,2

4,36,49,512,715,919,122,225,428,631,834,938,141,344,547,6

><

Standard

LC-I10 12,8 mm

9,5 mm

><

><

Flanged

3LC-I10 16,4 mm

10,8 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 65: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

65

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® 90F Lockbolt - Aluminium 6061

Stem : Aluminium 6061 | Head : Countersunk

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

>< >> <<><k

(mm)

min-max (mm)

StandardLC-I12

Flanged3LC-I12

><

l3(mm)

9,8 - 9,9 10,7 13,6 6,19,59,65 - 9,78

18,1 4,3

60,663,866,970,173,376,579,682,886,089,292,395,598,7101,9

6,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

4,0 - 10,37,1 - 13,510,3 - 16,713,5 - 19,816,7 - 23,019,8 - 26,223,0 - 29,426,2 - 32,529,4 - 35,732,5 - 38,935,7 - 42,138,9 - 45,242,1 - 48,445,2 - 51,6

C6L90-F12-6C6L90-F12-8C6L90-F12-10C6L90-F12-12C6L90-F12-14C6L90-F12-16C6L90-F12-18C6L90-F12-20C6L90-F12-22C6L90-F12-24C6L90-F12-26C6L90-F12-28

C6L90-F12-32C6L90-F12-30

24,828,031,234,437,540,743,947,150,253,456,659,862,966,1

6,49,512,715,919,122,225,428,631,834,938,141,344,547,6

><

Standard

LC-I12 15,4 mm

11,9 mm

><

><

Flanged

3LC-I12 19,7 mm

13,5 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 66: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

66

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® R Lockbolt - Steel

Stem : Steel | Head : Truss

5,0 - 5,2 7,3 7,7 4,6

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

4,84,85 - 4,95

11,9 2,3

1,6 - 4,83,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

0,4 - 3,62,0 - 5,23,6 - 6,85,2 - 8,46,8 - 9,98,4 - 11,59,9 - 13,111,5 - 14,713,1 - 16,314,7 - 17,916,3 - 19,517,9 - 21,119,5 - 22,621,1 - 24,222,6 - 25,824,2 - 27,425,8 - 29,027,4 - 30,629,0 - 32,230,6 - 33,832,2 - 35,333,8 - 36,935,3 - 38,536,9 - 40,138,5 - 41,740,1 - 43,341,7 - 44,943,3 - 46,544,9 - 48,0

48,0 - 51,246,5 - 49,6

C6LT-R6-2GC6LT-R6-3GC6LT-R6-4GC6LT-R6-5GC6LT-R6-6GC6LT-R6-7GC6LT-R6-8GC6LT-R6-9GC6LT-R6-10GC6LT-R6-11GC6LT-R6-12GC6LT-R6-13GC6LT-R6-14GC6LT-R6-15GC6LT-R6-16GC6LT-R6-17GC6LT-R6-18GC6LT-R6-19GC6LT-R6-20GC6LT-R6-21GC6LT-R6-22GC6LT-R6-23GC6LT-R6-24GC6LT-R6-25GC6LT-R6-26GC6LT-R6-27GC6LT-R6-28GC6LT-R6-29GC6LT-R6-30GC6LT-R6-31GC6LT-R6-32G

10,612,213,715,316,918,520,121,723,324,926,428,029,631,232,834,436,037,639,140,742,343,945,547,148,750,351,853,455,0

58,256,6

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-R6G

Flanged3LC-2R6G

><

l3(mm)

39,140,742,343,945,447,048,650,251,853,455,056,658,159,761,362,964,566,167,769,370,872,474,075,677,278,880,482,083,5

86,785,1

><

Standard

2LC-R6G 8,1 mm

6,2 mm

><

><

Flanged

3LC-2R6G 10,0 mm

7,4 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 67: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

67

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® R Lockbolt - Steel

Stem : Steel | Head : Truss

6,6 - 6,8 13,3 13,6 8,0

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

6,46,45 - 6,58 15,1 3,0

1,6 - 4,83,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

0,0 - 3,21,6 - 4,83,2 - 6,34,8 - 7,96,3 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,017,5 - 20,619,0 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,730,2 - 33,331,7 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,442,9 - 46,044,4 - 47,6

47,6 - 50,846 - 49,2

C6LT-R8-2GC6LT-R8-3GC6LT-R8-4GC6LT-R8-5GC6LT-R8-6GC6LT-R8-7GC6LT-R8-8GC6LT-R8-9GC6LT-R8-10GC6LT-R8-11GC6LT-R8-12GC6LT-R8-13GC6LT-R8-14GC6LT-R8-15GC6LT-R8-16G

C6LT-R8-20GC6LT-R8-21GC6LT-R8-22GC6LT-R8-23GC6LT-R8-24GC6LT-R8-25GC6LT-R8-26GC6LT-R8-27GC6LT-R8-28GC6LT-R8-29GC6LT-R8-30GC6LT-R8-31GC6LT-R8-32G

12,914,516,117,619,220,822,424,025,627,228,830,331,933,535,136,738,339,941,543,044,646,247,849,451,052,654,255,757,3

60,558,9

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-R8G

Flanged3LC-2R8G

><

l3(mm)

42,043,645,246,848,450,051,653,254,756,357,959,561,162,764,365,967,469,070,672,273,875,477,078,680,181,783,384,986,5

89,788,1

C6LT-R8-17GC6LT-R8-18GC6LT-R8-19G

><

Standard

2LC-R8G 10,6 mm

8,1 mm

><

><

Flanged

3LC-2R8G 13,2 mm

9,6 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 68: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

68

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® R Lockbolt - Steel

Stem : Steel | Head : Truss

8,2 - 8,3 20,5 21,0 12,5

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

7,98,05 - 8,18 20,2 3,6

51,955,158,361,564,667,871,074,277,380,583,786,990,093,296,4

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

1,2 - 7,54,4 - 10,77,5 - 13,910,7 - 17,113,9 - 20,217,1 - 23,420,2 - 26,623,4 - 29,826,6 - 32,929,8 - 36,132,9 - 39,336,1 - 42,539,3 - 45,642,5 - 48,845,6 - 52,0

C6LT-R10-4GC6LT-R10-6GC6LT-R10-8GC6LT-R10-10GC6LT-R10-12GC6LT-R10-14GC6LT-R10-16GC6LT-R10-18GC6LT-R10-20GC6LT-R10-22GC6LT-R10-24GC6LT-R10-26GC6LT-R10-28G

C6LT-R10-32GC6LT-R10-30G

19,722,926,129,232,435,638,841,945,148,351,554,657,861,064,2

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-R10G

Flanged3LC-2R10G

><

l3(mm)

><

Standard

2LC-R10G 12,8 mm

9,5 mm

><

><

Flanged

3LC-2R10G 16,4 mm

10,8 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 69: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

69

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® R Lockbolt - Steel

Stem : Steel | Head : Truss

9,8 - 9,9 28,9 30,4 17,9

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

9,59,65 - 9,78 23,4 4,3

57,360,563,766,870,073,276,479,582,785,989,192,295,498,6101,8

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

0,8 - 7,14,0 - 10,37,1 - 13,510,3 - 16,713,5 - 19,816,7 - 23,019,8 - 26,223,0 - 29,426,2 - 32,529,4 - 35,732,5 - 38,935,7 - 42,138,9 - 45,242,1 - 48,445,2 - 51,6

C6LT-R12-4GC6LT-R12-6GC6LT-R12-8GC6LT-R12-10GC6LT-R12-12GC6LT-R12-14GC6LT-R12-16GC6LT-R12-18GC6LT-R12-20GC6LT-R12-22GC6LT-R12-24GC6LT-R12-26GC6LT-R12-28G

C6LT-R12-32GC6LT-R12-30G

21,724,828,031,234,437,540,743,947,150,253,456,659,862,966,1

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-R12G

Flanged3LC-2R12G

><

l3(mm)

><

Standard

2LC-R12G 15,4 mm

11,9 mm

><

><

Flanged

3LC-2R12G 19,7 mm

13,5 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 70: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

70

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® U Lockbolt - Stainless Steel

Stem : Stainless steel | Head : Truss

5,0 - 5,2 6,5 8,9 4,6

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

4,84,85 - 4,95

11,9 2,3

1,6 - 4,83,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

0,4 - 3,62,0 - 5,23,6 - 6,85,2 - 8,46,8 - 9,98,4 - 11,59,9 - 13,111,5 - 14,713,1 - 16,314,7 - 17,916,3 - 19,517,9 - 21,119,5 - 22,621,1 - 24,222,6 - 25,824,2 - 27,425,8 - 29,027,4 - 30,629,0 - 32,230,6 - 33,832,2 - 35,333,8 - 36,935,3 - 38,536,9 - 40,138,5 - 41,740,1 - 43,341,7 - 44,943,3 - 46,544,9 - 48,0

48,0 - 51,246,5 - 49,6

C6LT-U6-2C6LT-U6-3C6LT-U6-4C6LT-U6-5C6LT-U6-6C6LT-U6-7C6LT-U6-8C6LT-U6-9C6LT-U6-10C6LT-U6-11C6LT-U6-12C6LT-U6-13C6LT-U6-14C6LT-U6-15C6LT-U6-16C6LT-U6-17C6LT-U6-18C6LT-U6-19C6LT-U6-20C6LT-U6-21C6LT-U6-22C6LT-U6-23C6LT-U6-24C6LT-U6-25C6LT-U6-26C6LT-U6-27C6LT-U6-28C6LT-U6-29C6LT-U6-30C6LT-U6-31C6LT-U6-32

10,612,213,715,316,918,520,121,723,324,926,428,029,631,232,834,436,037,639,140,742,343,945,547,148,750,351,853,455,0

58,256,6

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-2CU6

Flanged3LC-2CU6

><

l3(mm)

39,140,742,343,945,447,048,650,251,853,455,056,658,159,761,362,964,566,167,769,370,872,474,075,677,278,880,482,083,5

86,785,1

><

Standard

2LC-2CU6 8,1 mm

6,2 mm

><

><

Flanged

3LC-2CU6 10,0 mm

7,4 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 71: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

71

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® U Lockbolt - Stainless Steel

Stem : Stainless steel | Head : Truss

6,6 - 6,8 16,7 15,8 8,0

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

6,46,45 - 6,58 15,1 3,0

1,6 - 4,83,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

0,0 - 3,21,6 - 4,83,2 - 6,34,8 - 7,96,3 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,017,5 - 20,619,0 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,730,2 - 33,331,7 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,442,9 - 46,044,4 - 47,6

47,6 - 50,846 - 49,2

C6LT-U8-2C6LT-U8-3C6LT-U8-4C6LT-U8-5C6LT-U8-6C6LT-U8-7C6LT-U8-8C6LT-U8-9C6LT-U8-10C6LT-U8-11C6LT-U8-12C6LT-U8-13C6LT-U8-14C6LT-U8-15C6LT-U8-16C6LT-U8-17C6LT-U8-18C6LT-U8-19C6LT-U8-20C6LT-U8-21C6LT-U8-22C6LT-U8-23C6LT-U8-24C6LT-U8-25C6LT-U8-26C6LT-U8-27C6LT-U8-28C6LT-U8-29C6LT-U8-30C6LT-U8-31C6LT-U8-32

12,914,516,117,619,220,822,424,025,627,228,830,331,933,535,136,738,339,941,543,044,646,247,849,451,052,654,255,757,3

60,558,9

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-2CU8

Flanged3LC-2CU8

><

l3(mm)

42,043,645,246,848,450,051,653,254,756,357,959,561,162,764,365,967,469,070,672,273,875,477,078,680,181,783,384,986,5

89,788,1

><

Standard

2LC-2CU8 10,6 mm

8,1 mm

><

><

Flanged

3LC-2CU8 13,2 mm

9,6 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 72: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

72

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® U Lockbolt - Stainless Steel

Stem : Stainless steel | Head : Truss

8,2 - 8,3 18,9 24,6 12,5

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

7,98,05 - 8,18 20,2 3,6

51,955,158,361,564,667,871,074,277,380,583,786,990,093,296,4

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

1,2 - 7,54,4 - 10,77,5 - 13,910,7 - 17,113,9 - 20,217,1 - 23,420,2 - 26,623,4 - 29,826,6 - 32,929,8 - 36,132,9 - 39,336,1 - 42,539,3 - 45,642,5 - 48,845,6 - 52,0

C6LT-U10-4C6LT-U10-6C6LT-U10-8C6LT-U10-10C6LT-U10-12C6LT-U10-14C6LT-U10-16C6LT-U10-18C6LT-U10-20C6LT-U10-22C6LT-U10-24C6LT-U10-26C6LT-U10-28

C6LT-U10-32C6LT-U10-30

19,722,926,129,232,435,638,841,945,148,351,554,657,861,064,2

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-2CU10

Flanged3LC-2CU10

><

l3(mm)

><

Standard

2LC-2CU10 12,8 mm

9,5 mm

><

><

Flanged

3LC-2CU10 16,4 mm

10,8 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 73: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

73

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® U Lockbolt - Stainless Steel

Stem : Stainless steel | Head : Truss

9,8 - 9,9 27,1 35,4 17,9

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

9,59,65 - 9,78 23,4 4,3

57,360,563,766,870,073,276,479,582,785,989,192,295,498,6101,8

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

0,8 - 7,14,0 - 10,37,1 - 13,510,3 - 16,713,5 - 19,816,7 - 23,019,8 - 26,223,0 - 29,426,2 - 32,529,4 - 35,732,5 - 38,935,7 - 42,138,9 - 45,242,1 - 48,445,2 - 51,6

C6LT-U12-4C6LT-U12-6C6LT-U12-8C6LT-U12-10C6LT-U12-12C6LT-U12-14C6LT-U12-16C6LT-U12-18C6LT-U12-20C6LT-U12-22C6LT-U12-24C6LT-U12-26C6LT-U12-28

C6LT-U12-32C6LT-U12-30

21,724,828,031,234,437,540,743,947,150,253,456,659,862,966,1

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-2CU12

Flanged3LC-2CU12

><

l3(mm)

><

Standard

2LC-2CU12 15,4 mm

11,9 mm

><

><

Flanged

3LC-2CU12 19,7 mm

13,5 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 74: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

74

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® C Lockbolt - Aluminium

Stem : Aluminium | Head : Truss

5,0 - 5,2 4,4 4,7 2,4

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

4,84,85 - 4,95

11,9 2,3

1,6 - 4,83,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

0,4 - 3,62,0 - 5,23,6 - 6,85,2 - 8,46,8 - 9,98,4 - 11,59,9 - 13,111,5 - 14,713,1 - 16,314,7 - 17,916,3 - 19,517,9 - 21,119,5 - 22,621,1 - 24,222,6 - 25,824,2 - 27,425,8 - 29,027,4 - 30,629,0 - 32,230,6 - 33,832,2 - 35,333,8 - 36,935,3 - 38,536,9 - 40,138,5 - 41,740,1 - 43,341,7 - 44,943,3 - 46,544,9 - 48,0

48,0 - 51,246,5 - 49,6

C6LT-C6-2C6LT-C6-3C6LT-C6-4C6LT-C6-5C6LT-C6-6C6LT-C6-7C6LT-C6-8C6LT-C6-9C6LT-C6-10C6LT-C6-11C6LT-C6-12C6LT-C6-13C6LT-C6-14C6LT-C6-15C6LT-C6-16C6LT-C6-17C6LT-C6-18C6LT-C6-19C6LT-C6-20C6LT-C6-21C6LT-C6-22C6LT-C6-23C6LT-C6-24C6LT-C6-25C6LT-C6-26C6LT-C6-27C6LT-C6-28C6LT-C6-29C6LT-C6-30C6LT-C6-31C6LT-C6-32

10,612,213,715,316,918,520,121,723,324,926,428,029,631,232,834,436,037,639,140,742,343,945,547,148,750,351,853,455,0

58,256,6

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-F6

Flanged3LC-F6

><

l3(mm)

39,140,742,343,945,447,048,650,251,853,455,056,658,159,761,362,964,566,167,769,370,872,474,075,677,278,880,482,083,5

86,785,1

><

Standard

2LC-F6 8,1 mm

6,2 mm

><

><

Flanged

3LC-F6 10,0 mm

7,4 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 75: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

75

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® C Lockbolt - Aluminium

Tige : Aluminium | Tête : Plate

6,6 - 6,8 8,0 8,3 4,2

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

6,46,45 - 6,58 15,1 3,0

1,6 - 4,83,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

0,0 - 3,21,6 - 4,83,2 - 6,34,8 - 7,96,3 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,017,5 - 20,619,0 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,730,2 - 33,331,7 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,442,9 - 46,044,4 - 47,6

47,6 - 50,846 - 49,2

C6LT-C8-2C6LT-C8-3C6LT-C8-4C6LT-C8-5C6LT-C8-6C6LT-C8-7C6LT-C8-8C6LT-C8-9C6LT-C8-10C6LT-C8-11C6LT-C8-12C6LT-C8-13C6LT-C8-14C6LT-C8-15C6LT-C8-16C6LT-C8-17C6LT-C8-18C6LT-C8-19C6LT-C8-20C6LT-C8-21C6LT-C8-22C6LT-C8-23C6LT-C8-24C6LT-C8-25C6LT-C8-26C6LT-C8-27C6LT-C8-28C6LT-C8-29C6LT-C8-30C6LT-C8-31C6LT-C8-32

12,914,516,117,619,220,822,424,025,627,228,830,331,933,535,136,738,339,941,543,044,646,247,849,451,052,654,255,757,3

60,558,9

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-F8

Flanged3LC-F8

><

l3(mm)

42,043,645,246,848,450,051,653,254,756,357,959,561,162,764,365,967,469,070,672,273,875,477,078,680,181,783,384,986,5

89,788,1

><

Standard

2LC-F8 10,6 mm

8,1 mm

><

><

Flanged

3LC-F8 13,2 mm

9,6 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 76: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

76

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® C Lockbolt - Aluminium

Stem : Aluminium | Head : Truss

8,2 - 8,3 12,7 13,0 6,7

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

7,98,05 - 8,18 20,2 3,6

51,955,158,361,564,667,871,074,277,380,583,786,990,093,296,4

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

1,2 - 7,54,4 - 10,77,5 - 13,910,7 - 17,113,9 - 20,217,1 - 23,420,2 - 26,623,4 - 29,826,6 - 32,929,8 - 36,132,9 - 39,336,1 - 42,539,3 - 45,642,5 - 48,845,6 - 52,0

C6LT-C10-4C6LT-C10-6C6LT-C10-8C6LT-C10-10C6LT-C10-12C6LT-C10-14C6LT-C10-16C6LT-C10-18C6LT-C10-20C6LT-C10-22C6LT-C10-24C6LT-C10-26C6LT-C10-28

C6LT-C10-32C6LT-C10-30

19,722,926,129,232,435,638,841,945,148,351,554,657,861,064,2

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-F10

Flanged3LC-F10

><

l3(mm)

><

Standard

2LC-F10 12,8 mm

9,5 mm

><

><

Flanged

3LC-F10 16,4 mm

10,8 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 77: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

77

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® C Lockbolt - Aluminium

Stem : Aluminium | Head : Truss

9,8 - 9,9 18,7 18,7 9,8

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

9,59,65 - 9,78 23,4 4,3

57,360,563,766,870,073,276,479,582,785,989,192,295,498,6101,8

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

0,8 - 7,14,0 - 10,37,1 - 13,510,3 - 16,713,5 - 19,816,7 - 23,019,8 - 26,223,0 - 29,426,2 - 32,529,4 - 35,732,5 - 38,935,7 - 42,138,9 - 45,242,1 - 48,445,2 - 51,6

C6LT-C12-4C6LT-C12-6C6LT-C12-8C6LT-C12-10C6LT-C12-12C6LT-C12-14C6LT-C12-16C6LT-C12-18C6LT-C12-20C6LT-C12-22C6LT-C12-24C6LT-C12-26C6LT-C12-28

C6LT-C12-32C6LT-C12-30

21,724,828,031,234,437,540,743,947,150,253,456,659,862,966,1

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC-F12

Flanged3LC-F12

><

l3(mm)

><

Standard

2LC-F12 15,4 mm

11,9 mm

><

><

Flanged

3LC-F12 19,7 mm

13,5 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 78: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

78

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® F Lockbolt - Aluminium 6061

Stem : Aluminium 6061 | Head : Truss

5,0 - 5,2 2,4 3,4 1,6

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

4,84,85 - 4,95

11,9 2,3

1,6 - 4,83,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

0,4 - 3,62,0 - 5,23,6 - 6,85,2 - 8,46,8 - 9,98,4 - 11,59,9 - 13,111,5 - 14,713,1 - 16,314,7 - 17,916,3 - 19,517,9 - 21,119,5 - 22,621,1 - 24,222,6 - 25,824,2 - 27,425,8 - 29,027,4 - 30,629,0 - 32,230,6 - 33,832,2 - 35,333,8 - 36,935,3 - 38,536,9 - 40,138,5 - 41,740,1 - 43,341,7 - 44,943,3 - 46,544,9 - 48,0

48,0 - 51,246,5 - 49,6

C6LT-F6-2C6LT-F6-3C6LT-F6-4C6LT-F6-5C6LT-F6-6C6LT-F6-7C6LT-F6-8C6LT-F6-9C6LT-F6-10C6LT-F6-11C6LT-F6-12C6LT-F6-13C6LT-F6-14C6LT-F6-15C6LT-F6-16C6LT-F6-17C6LT-F6-18C6LT-F6-19C6LT-F6-20C6LT-F6-21C6LT-F6-22C6LT-F6-23C6LT-F6-24C6LT-F6-25C6LT-F6-26C6LT-F6-27C6LT-F6-28C6LT-F6-29C6LT-F6-30C6LT-F6-31C6LT-F6-32

10,612,213,715,316,918,520,121,723,324,926,428,029,631,232,834,436,037,639,140,742,343,945,547,148,750,351,853,455,0

58,256,6

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

StandardLC-I6

Flanged3LC-I6

><

l3(mm)

39,140,742,343,945,447,048,650,251,853,455,056,658,159,761,362,964,566,167,769,370,872,474,075,677,278,880,482,083,5

86,785,1

><

Standard

LC-I6 8,1 mm

6,2 mm

><

><

Flanged

3LC-I6 10,0 mm

7,4 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 79: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

79

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® F Lockbolt -Aluminium 6061

Stem : Aluminium 6061 | Head : Truss

6,6 - 6,8 4,3 6,1 2,8

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

6,46,45 - 6,58 15,1 3,0

1,6 - 4,83,2 - 6,44,8 - 7,96,4 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,117,5 - 20,619,1 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,830,2 - 33,331,8 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,542,9 - 46,044,5 - 47,646,0 - 49,2

49,2 - 52,447,6 - 50,8

0,0 - 3,21,6 - 4,83,2 - 6,34,8 - 7,96,3 - 9,57,9 - 11,19,5 - 12,711,1 - 14,312,7 - 15,914,3 - 17,515,9 - 19,017,5 - 20,619,0 - 22,220,6 - 23,822,2 - 25,423,8 - 27,025,4 - 28,627,0 - 30,228,6 - 31,730,2 - 33,331,7 - 34,933,3 - 36,534,9 - 38,136,5 - 39,738,1 - 41,339,7 - 42,941,3 - 44,442,9 - 46,044,4 - 47,6

47,6 - 50,846 - 49,2

C6LT-F8-2C6LT-F8-3C6LT-F8-4C6LT-F8-5C6LT-F8-6C6LT-F8-7C6LT-F8-8C6LT-F8-9C6LT-F8-10C6LT-F8-11C6LT-F8-12C6LT-F8-13C6LT-F8-14C6LT-F8-15C6LT-F8-16C6LT-F8-17C6LT-F8-18C6LT-F8-19C6LT-F8-20C6LT-F8-21C6LT-F8-22C6LT-F8-23C6LT-F8-24C6LT-F8-25C6LT-F8-26C6LT-F8-27C6LT-F8-28C6LT-F8-29C6LT-F8-30C6LT-F8-31C6LT-F8-32

12,914,516,117,619,220,822,424,025,627,228,830,331,933,535,136,738,339,941,543,044,646,247,849,451,052,654,255,757,3

60,558,9

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

StandardLC-I8

Flanged3LC-I8

><

l3(mm)

42,043,645,246,848,450,051,653,254,756,357,959,561,162,764,365,967,469,070,672,273,875,477,078,680,181,783,384,986,5

89,788,1

><

Standard

LC-I8 10,6 mm

8,1 mm

><

><

Flanged

3LC-I8 13,2 mm

9,6 mm

><

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 80: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

80

Range of LockBolt®

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® F Lockbolt - Aluminium 6061

Stem : Aluminium 6061 | Head : Truss

8,2 - 8,3 6,9 9,5 4,3

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

7,98,05 - 8,18 20,2 3,6

51,955,158,361,564,667,871,074,277,380,583,786,990,093,296,4

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

1,2 - 7,54,4 - 10,77,5 - 13,910,7 - 17,113,9 - 20,217,1 - 23,420,2 - 26,623,4 - 29,826,6 - 32,929,8 - 36,132,9 - 39,336,1 - 42,539,3 - 45,642,5 - 48,845,6 - 52,0

C6LT-F10-4C6LT-F10-6C6LT-F10-8C6LT-F10-10C6LT-F10-12C6LT-F10-14C6LT-F10-16C6LT-F10-18C6LT-F10-20C6LT-F10-22C6LT-F10-24C6LT-F10-26C6LT-F10-28

C6LT-F10-32C6LT-F10-30

19,722,926,129,232,435,638,841,945,148,351,554,657,861,064,2

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

StandardLC-I10

Flanged3LC-I10

><

l3(mm)

><

Standard

LC-I10 12,8 mm

9,5 mm

><

><

Flanged

3LC-I10 16,4 mm

10,8 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 81: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

81

High sustainability and high resistance to vibrationsHas 6 grooves in the joining area allowing to get a greater clamping rangeWide flange collar available: enables installation into non metallic materials

C6L® F Lockbolt - Aluminium 6061

Stem : Aluminium 6061 | Head : Truss

9,9 10,7 13,6 6,1

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

9,59,65 - 9,78 23,4 4,3

57,360,563,766,870,073,276,479,582,785,989,192,295,498,6101,8

3,2 - 9,56,4 - 12,79,5 - 15,912,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,625,4 - 31,828,6 - 34,931,8 - 38,134,9 - 41,338,1 - 44,541,3 - 47,644,5 - 50,847,6 - 54,0

0,8 - 7,14,0 - 10,37,1 - 13,510,3 - 16,713,5 - 19,816,7 - 23,019,8 - 26,223,0 - 29,426,2 - 32,529,4 - 35,732,5 - 38,935,7 - 42,138,9 - 45,242,1 - 48,445,2 - 51,6

C6LT-F12-4C6LT-F12-6C6LT-F12-8C6LT-F12-10C6LT-F12-12C6LT-F12-14C6LT-F12-16C6LT-F12-18C6LT-F12-20C6LT-F12-22C6LT-F12-24C6LT-F12-26C6LT-F12-28

C6LT-F12-32C6LT-F12-30

21,724,828,031,234,437,540,743,947,150,253,456,659,862,966,1

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

StandardLC-I12

Flanged3LC-I12

><

l3(mm)

><

Standard

LC-I12 15,4 mm

11,9 mm

><

><

Flanged

3LC-I12 19,7 mm

13,5 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 82: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

8282

Range of LockBolt®

C120L® is a 8.8 grade small diameter LockBolt (improved version of C6L) with a semi-circular head, reducedand countersunkStandard stem and head (for a installation into non metallic materials)

C120L® R Lockbolt - Steel

Stem : Steel | Head : Brazier

5,0 - 5,2 9,8 10,8 5,3

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

4,8 9,9 3,2

39,140,742,343,945,447,048,650,251,853,455,056,658,159,761,362,964,566,167,769,370,872,474,075,677,278,880,482,083,5

86,785,1

1,59 - 4,763,18 - 6,354,76 - 7,946,35 - 9,537,94 - 11,119,53 - 12,7011,11 - 14,2912,70 - 15,8814,29 - 17,4615,88 - 19,0517,46 - 20,6419,05 - 22,2320,64 - 23,8122,23 - 25,4023,81 - 26,9925,40 - 28,5826,99 - 30,1628,58 - 31,7530,16 - 33,3431,75 - 34,9333,34 - 36,5134,93 - 38,1036,51 - 39,6938,10 - 41,2839,69 - 42,8641,28 - 44,4542,86 - 46,0444,45 - 47,6346,04 - 49,21

49,21 - 52,3947,63 - 50,80

0,42 - 3,592,01 - 5,183,59 - 6,775,18 - 8,366,77 - 9,948,36 - 11,539,94 - 13,1211,53 - 14,7113,12 - 16,2914,71 - 17,8816,29 - 19,4717,88 - 21,0619,47 - 22,6421,06 - 24,2322,64 - 25,8224,23 - 27,4125,82 - 28,9927,41 - 30,5828,99 - 32,1730,58 - 33,7632,17 - 35,3433,76 - 36,9335,34 - 38,5236,93 - 40,1138,52 - 41,6940,11 - 43,2841,69 - 44,8743,28 - 46,4644,87 - 48,04

48,04 - 51,2246,46 - 49,63

C120LB-R6-2GC120LB-R6-3GC120LB-R6-4GC120LB-R6-5GC120LB-R6-6GC120LB-R6-7GC120LB-R6-8GC120LB-R6-9GC120LB-R6-10GC120LB-R6-11GC120LB-R6-12GC120LB-R6-13GC120LB-R6-14GC120LB-R6-15GC120LB-R6-16GC120LB-R6-17GC120LB-R6-18GC120LB-R6-19GC120LB-R6-20GC120LB-R6-21GC120LB-R6-22GC120LB-R6-23GC120LB-R6-24GC120LB-R6-25GC120LB-R6-26GC120LB-R6-27GC120LB-R6-28GC120LB-R6-29GC120LB-R6-30G

C120LB-R6-32GC120LB-R6-31G

10,612,213,715,316,918,520,121,723,324,926,428,029,631,232,834,436,037,639,140,742,343,945,547,148,750,351,853,455,0

58,256,6

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

Standard2LC120-R6G

Flanged3LC120-2R6G

><

l3(mm)

><

Standard

2LC120-R6G 8,1 mm

6,2 mm

><

><

Flanged

3LC120-2R6G 10,0 mm

7,4 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 83: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

8383

Stem : Steel | Head : Brazier

6,6 - 6,8 16,9 19,1 10,2

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

6,4 13,2 3,9

42,043,645,246,848,450,051,653,254,756,357,959,561,162,764,365,967,469,070,672,273,875,477,078,680,181,783,384,986,588,189,7

1,59 - 4,763,18 - 6,354,76 - 7,946,35 - 9,537,94 - 11,117,94 - 11,1111,11 - 14,2912,70 - 15,8814,29 - 17,4615,88 - 19,0517,46 - 20,6419,05 - 22,2320,64 - 23,8122,23 - 25,4023,81 - 26,9925,40 - 28,5826,99 - 30,1628,58 - 31,7530,16 - 33,3431,75 - 34,9333,34 - 36,5134,93 - 38,1036,51 - 39,6938,10 - 41,2839,69 - 42,8641,28 - 44,4542,86 - 46,0444,45 - 47,6346,04 - 49,21

49,21 - 52,3947,63 - 50,80

0,01 - 3,161,57 - 4,753,16 - 6,344,75 - 7,926,34 - 9,517,92 - 11,109,51 - 12,6911,10 - 14,2712,69 - 15,8614,27 - 17,4515,86 - 19,0417,45 - 20,6219,04 - 22,2120,62 - 23,8022,21 - 25,3923,80 - 26,9725,39 - 28,5626,97 - 30,1528,56 - 31,7430,15 - 33,3231,74 - 34,9133,32 - 36,5034,91 - 38,0936,50 - 39,6738,09 - 41,2639,67 - 42,8541,26 - 44,4442,85 - 46,0244,44 - 47,61

47,61 - 50,7946,02 - 49,20

C120LB-R8-2GC120LB-R8-3GC120LB-R8-4GC120LB-R8-5GC120LB-R8-6GC120LB-R8-7GC120LB-R8-8GC120LB-R8-9GC120LB-R8-10GC120LB-R8-11GC120LB-R8-12GC120LB-R8-13GC120LB-R8-14GC120LB-R8-15GC120LB-R8-16GC120LB-R8-17GC120LB-R8-18GC120LB-R8-19GC120LB-R8-20GC120LB-R8-21GC120LB-R8-22GC120LB-R8-23GC120LB-R8-24GC120LB-R8-25GC120LB-R8-26GC120LB-R8-27GC120LB-R8-28GC120LB-R8-29GC120LB-R8-30G

C120LB-R8-32GC120LB-R8-31G

12,914,516,117,619,220,822,424,025,627,228,830,331,933,535,136,738,339,941,543,044,646,247,849,451,052,654,255,7

58,960,5

57,3

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

Standard2LC120-R8G

Flanged3LC120-2R8G

><

l3(mm)

C120L® is a 8.8 grade small diameter LockBolt (improved version of C6L) with a semi-circular head, reducedand countersunkStandard stem and head (for a installation into non metallic materials)

C120L® R Lockbolt - Steel

><

Standard

2LC120-R8G 10,6 mm

8,1 mm

><

><

Flanged

3LC120-2R8G 13,2 mm

9,6 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 84: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

8484

Range of LockBolt®

C120L® is a 8.8 grade small diameter LockBolt (improved version of C6L) with a semi-circular head, reducedand countersunkStandard stem and head (for a installation into non metallic materials)

C120L® R Lockbolt - Steel

Stem : Steel | Head : Brazier

8,2 - 8,3 28,0 29,8 18,7

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

7,9 16,5 5,1

51,955,158,361,564,667,871,074,277,380,583,786,990,093,296,4

3,18 - 9,536,35 - 12,709,53 - 15,8812,70 - 19,0515,88 - 22,2319,05 - 25,4022,23 - 28,5825,40 - 31,7528,58 - 34,9331,75 - 38,1034,93 - 41,2838,10 - 44,4541,28 - 47,6344,45 - 50,8047,63 - 53,98

1,19 - 7,544,37 - 10,727,54 - 13,8910,72 - 17,0713,89 - 20,2417,07 - 23,4220,24 - 26,5923,42 - 29,7726,59 - 32,9429,77 - 36,1232,94 - 39,2936,12 - 42,4739,29 - 45,6442,47 - 48,8245,64 - 51,99

C120LB-R10-4GC120LB-R10-6GC120LB-R10-8GC120LB-R10-10GC120LB-R10-12GC120LB-R10-14GC120LB-R10-16GC120LB-R10-18GC120LB-R10-20GC120LB-R10-22GC120LB-R10-24GC120LB-R10-26GC120LB-R10-28GC120LB-R10-30GC120LB-R10-32G

19,722,926,129,232,435,638,841,945,148,351,554,657,861,064,2

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC120-R10G

Flanged3LC120-2R10G

><

l3(mm)

><

Standard

2LC120-R10G 12,8 mm

9,5 mm

><

><

Flanged

3LC120-2R10G 16,4 mm

10,8 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 85: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

8585

C120L® is a 8.8 grade small diameter LockBolt (improved version of C6L) with a semi-circular head, reducedand countersunkStandard stem and head (for a installation into non metallic materials)

C120L® R Lockbolt - Steel

Stem : Steel | Head : Brazier

9,9 41,4 42,7 22,2

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

9,59,65 - 9,78 19,8 6,3

57,360,563,766,870,073,276,479,582,785,989,192,295,498,6101,8

3,18 - 9,536,35 - 12,709,53 - 15,8812,70 - 19,0515,88 - 22,2319,05 - 25,4022,23 - 28,5825,40 - 31,7528,58 - 34,9331,75 - 38,1034,93 - 41,2838,10 - 44,4541,28 - 47,6344,45 - 50,8047,63 - 53,98

0,79 - 7,143,96 - 10,317,14 - 13,4910,31 - 16,6613,49 - 19,8416,66 - 23,0119,84 - 26,1623,01 - 29,3626,19 - 32,5429,36 - 35,7132,54 - 38,8935,71 - 42,0638,89 - 45,2442,06 - 48,4145,24 - 51,59

C120LB-R12-4GC120LB-R12-6GC120LB-R12-8GC120LB-R12-10GC120LB-R12-12GC120LB-R12-14GC120LB-R12-16GC120LB-R12-18GC120LB-R12-20GC120LB-R12-22GC120LB-R12-24GC120LB-R12-26GC120LB-R12-28GC120LB-R12-30GC120LB-R12-32G

21,724,828,031,234,437,540,743,947,150,253,456,659,862,966,1

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC120-R12G

Flanged3LC120-2R12G

><

l3(mm)

><

Standard

2LC120-R12G 15,4 mm

11,9 mm

><

><

Flanged

3LC120-2R12G 19,7 mm

13,5 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 86: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

8686

Range of LockBolt®

C120L® is a 8.8 grade small diameter LockBolt (improved version of C6L) with a semi-circular head, reducedand countersunkStandard stem and head (for a installation into non metallic materials)

C120L® R Lockbolt - Steel

Stem : Steel | Head : Truss

5,0 - 5,2 9,8 10,8 5,3

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

4,8 11,9 2,3

39,140,742,343,945,447,048,650,251,853,455,056,658,159,761,362,964,566,167,769,370,872,474,075,677,278,880,482,083,5

86,785,1

1,59 - 4,763,18 - 6,354,76 - 7,946,35 - 9,537,94 - 11,119,53 - 12,7011,11 - 14,2912,70 - 15,8814,29 - 17,4615,88 - 19,0517,46 - 20,6419,05 - 22,2320,64 - 23,8122,23 - 25,4023,81 - 26,9925,40 - 28,5826,99 - 30,1628,58 - 31,7530,16 - 33,3431,75 - 34,9333,34 - 36,5134,93 - 38,1036,51 - 39,6938,10 - 41,2839,69 - 42,8641,28 - 44,4542,86 - 46,0444,45 - 47,6346,04 - 49,21

49,21 - 52,3947,63 - 50,80

0,42 - 3,592,01 - 5,183,59 - 6,775,18 - 8,366,77 - 9,948,36 - 11,539,94 - 13,1211,53 - 14,7113,12 - 16,2914,71 - 17,8816,29 - 19,4717,88 - 21,0619,47 - 22,6421,06 - 24,2322,64 - 25,8224,23 - 27,4125,82 - 28,9927,41 - 30,5828,99 - 32,1730,58 - 33,7632,17 - 35,3433,76 - 36,9335,34 - 38,5236,93 - 40,1138,52 - 41,6940,11 - 43,2841,69 - 44,8743,28 - 46,4644,87 - 48,04

48,04 - 51,2246,46 - 49,63

C120LT-R6-2GC120LT-R6-3GC120LT-R6-4GC120LT-R6-5GC120LT-R6-6GC120LT-R6-7GC120LT-R6-8GC120LT-R6-9GC120LT-R6-10GC120LT-R6-11GC120LT-R6-12GC120LT-R6-13GC120LT-R6-14GC120LT-R6-15GC120LT-R6-16GC120LT-R6-17GC120LT-R6-18GC120LT-R6-19GC120LT-R6-20GC120LT-R6-21GC120LT-R6-22GC120LT-R6-23GC120LT-R6-24GC120LT-R6-25GC120LT-R6-26GC120LT-R6-27GC120LT-R6-28GC120LT-R6-29GC120LT-R6-30G

C120LT-R6-32GC120LT-R6-31G

10,612,213,715,316,918,520,121,723,324,926,428,029,631,232,834,436,037,639,140,742,343,945,547,148,750,351,853,455,0

58,256,6

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

Standard2LC120-R6G

Flanged3LC120-2R6G

><

l3(mm)

><

Standard

2LC120-R6G 8,1 mm

6,2 mm

><

><

Flanged

3LC120-2R6G 10,0 mm

7,4 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 87: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

8787

Stem : Steel | Head : Truss

6,6 - 6,8 16,9 19,1 10,2

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

6,4 15,1 3,0

42,043,645,246,848,450,051,653,254,756,357,959,561,162,764,365,967,469,070,672,273,875,477,078,680,181,783,384,986,588,189,7

1,59 - 4,763,18 - 6,354,76 - 7,946,35 - 9,537,94 - 11,117,94 - 11,1111,11 - 14,2912,70 - 15,8814,29 - 17,4615,88 - 19,0517,46 - 20,6419,05 - 22,2320,64 - 23,8122,23 - 25,4023,81 - 26,9925,40 - 28,5826,99 - 30,1628,58 - 31,7530,16 - 33,3431,75 - 34,9333,34 - 36,5134,93 - 38,1036,51 - 39,6938,10 - 41,2839,69 - 42,8641,28 - 44,4542,86 - 46,0444,45 - 47,6346,04 - 49,21

49,21 - 52,3947,63 - 50,80

0,01 - 3,161,57 - 4,753,16 - 6,344,75 - 7,926,34 - 9,517,92 - 11,109,51 - 12,6911,10 - 14,2712,69 - 15,8614,27 - 17,4515,86 - 19,0417,45 - 20,6219,04 - 22,2120,62 - 23,8022,21 - 25,3923,80 - 26,9725,39 - 28,5626,97 - 30,1528,56 - 31,7430,15 - 33,3231,74 - 34,9133,32 - 36,5034,91 - 38,0936,50 - 39,6738,09 - 41,2639,67 - 42,8541,26 - 44,4442,85 - 46,0244,44 - 47,61

47,61 - 50,7946,02 - 49,20

C120LT-R8-2GC120LT-R8-3GC120LT-R8-4GC120LT-R8-5GC120LT-R8-6GC120LT-R8-7GC120LT-R8-8GC120LT-R8-9GC120LT-R8-10GC120LT-R8-11GC120LT-R8-12GC120LT-R8-13GC120LT-R8-14GC120LT-R8-15GC120LT-R8-16GC120LT-R8-17GC120LT-R8-18GC120LT-R8-19GC120LT-R8-20GC120LT-R8-21GC120LT-R8-22GC120LT-R8-23GC120LT-R8-24GC120LT-R8-25GC120LT-R8-26GC120LT-R8-27GC120LT-R8-28GC120LT-R8-29GC120LT-R8-30G

C120LT-R8-32GC120LT-R8-31G

12,914,516,117,619,220,822,424,025,627,228,830,331,933,535,136,738,339,941,543,044,646,247,849,451,052,654,255,7

58,960,5

57,3

1,63,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

Standard2LC120-R8G

Flanged3LC120-2R8G

><

l3(mm)

C120L® is a 8.8 grade small diameter LockBolt (improved version of C6L) with a semi-circular head, reducedand countersunkStandard stem and head (for a installation into non metallic materials)

C120L® R Lockbolt - Steel

><

Standard

2LC120-R8G 10,6 mm

8,1 mm

><

><

Flanged

3LC120-2R8G 13,2 mm

9,6 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 88: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

88

Range of LockBolt®

C120L® is a 8.8 grade small diameter LockBolt (improved version of C6L) with a semi-circular head, reducedand countersunkStandard stem and head (for a installation into non metallic materials)

C120L® R Lockbolt - Steel

Stem : Steel | Head : Truss

8,2 - 8,3 28,0 29,8 18,7

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

7,9 20,2 3,6

51,955,158,361,564,667,871,074,277,380,583,786,990,093,296,4

3,18 - 9,536,35 - 12,709,53 - 15,8812,70 - 19,0515,88 - 22,2319,05 - 25,4022,23 - 28,5825,40 - 31,7528,58 - 34,9331,75 - 38,1034,93 - 41,2838,10 - 44,4541,28 - 47,6344,45 - 50,8047,63 - 53,98

1,19 - 7,544,37 - 10,727,54 - 13,8910,72 - 17,0713,89 - 20,2417,07 - 23,4220,24 - 26,5923,42 - 29,7726,59 - 32,9429,77 - 36,1232,94 - 39,2936,12 - 42,4739,29 - 45,6442,47 - 48,8245,64 - 51,99

C120LT-R10-4GC120LT-R10-6GC120LT-R10-8GC120LT-R10-10GC120LT-R10-12GC120LT-R10-14GC120LT-R10-16GC120LT-R10-18GC120LT-R10-20GC120LT-R10-22GC120LT-R10-24GC120LT-R10-26GC120LT-R10-28GC120LT-R10-30GC120LT-R10-32G

19,722,926,129,232,435,638,841,945,148,351,554,657,861,064,2

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC120-R10G

Flanged3LC120-2R10G

><

l3(mm)

><

Standard

2LC120-R10G 12,8 mm

9,5 mm

><

><

Flanged

3LC120-2R10G 16,4 mm

10,8 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 89: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

89

Stem : Steel | Head : Truss

C120L® is a 8.8 grade small diameter LockBolt (improved version of C6L) with a semi-circular head, reducedand countersunkStandard stem and head (for a installation into non metallic materials)

C120L® R Lockbolt - Steel

9,9 41,4 42,7 22,2

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

9,59,65 - 9,78 23,4 4,3

57,360,563,766,870,073,276,479,582,785,989,192,295,498,6101,8

3,18 - 9,536,35 - 12,709,53 - 15,8812,70 - 19,0515,88 - 22,2319,05 - 25,4022,23 - 28,5825,40 - 31,7528,58 - 34,9331,75 - 38,1034,93 - 41,2838,10 - 44,4541,28 - 47,6344,45 - 50,8047,63 - 53,98

0,79 - 7,143,96 - 10,317,14 - 13,4910,31 - 16,6613,49 - 19,8416,66 - 23,0119,84 - 26,1623,01 - 29,3626,19 - 32,5429,36 - 35,7132,54 - 38,8935,71 - 42,0638,89 - 45,2442,06 - 48,4145,24 - 51,59

C120LT-R12-4GC120LT-R12-6GC120LT-R12-8GC120LT-R12-10GC120LT-R12-12GC120LT-R12-14GC120LT-R12-16GC120LT-R12-18GC120LT-R12-20GC120LT-R12-22GC120LT-R12-24GC120LT-R12-26GC120LT-R12-28GC120LT-R12-30GC120LT-R12-32G

21,724,828,031,234,437,540,743,947,150,253,456,659,862,966,1

3,26,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC120-R12G

Flanged3LC120-2R12G

><

l3(mm)

><

Standard

2LC120-R12G 15,4 mm

11,9 mm

><

><

Flanged

3LC120-2R12G 19,7 mm

13,5 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 90: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

90

Range of LockBolt®

C120L® is a 8.8 grade small diameter LockBolt (improved version of C6L) with a semi-circular head, reducedand countersunkStandard stem and head (for a installation into non metallic materials)

C120L® R Lockbolt - Steel

Stem : Steel | Head : Countersunk 90°

5,0 - 5,2 9,8 10,8 5,3

Clampload

kN

4,8 9,1 2,2

39,9270,1271,7273,2274,8276,4278,0279,6281,2282,8284,4285,9287,5289,1290,7292,3293,9295,5297,1298,6300,2301,8303,4305,0306,6308,2309,8311,3

314,5312,9

3,18 - 6,354,76 - 7,946,35 - 9,537,94 - 11,119,53 - 12,7011,11 - 14,2912,70 - 15,8814,29 - 17,4615,88 - 19,0517,46 - 20,6419,05 - 22,2320,64 - 23,8122,23 - 25,4023,81 - 26,9925,40 - 28,5826,99 - 30,1628,58 - 31,7530,16 - 33,3431,75 - 34,9333,34 - 36,5134,93 - 38,1036,51 - 39,6938,10 - 41,2839,69 - 42,8641,28 - 44,4542,86 - 46,0444,45 - 47,6346,04 - 49,21

49,21 - 52,3947,63 - 50,80

2,01 - 5,183,59 - 6,775,18 - 8,366,77 - 9,948,36 - 11,539,94 - 13,1211,53 - 14,7113,12 - 16,2914,71 - 17,8816,29 - 19,4717,88 - 21,0619,47 - 22,6421,06 - 24,2322,64 - 25,8224,23 - 27,4125,82 - 28,9927,41 - 30,5828,99 - 32,1730,58 - 33,7632,17 - 35,3433,76 - 36,9335,34 - 38,5236,93 - 40,1138,52 - 41,6940,11 - 43,2841,69 - 44,8743,28 - 46,4644,87 - 48,04

48,04 - 51,2246,46 - 49,63

C120L90-R6-3GC120L90-R6-4GC120L90-R6-5GC120L90-R6-6GC120L90-R6-7GC120L90-R6-8GC120L90-R6-9GC120L90-R6-10GC120L90-R6-11GC120L90-R6-12GC120L90-R6-13GC120L90-R6-14GC120L90-R6-15GC120L90-R6-16GC120L90-R6-17GC120L90-R6-18GC120L90-R6-19GC120L90-R6-20GC120L90-R6-21GC120L90-R6-22GC120L90-R6-23GC120L90-R6-24GC120L90-R6-25GC120L90-R6-26GC120L90-R6-27GC120L90-R6-28GC120L90-R6-29GC120L90-R6-30G

C120L90-R6-32GC120L90-R6-31G

12,213,715,316,918,520,121,723,324,926,428,029,631,232,834,436,037,639,140,742,343,945,547,148,750,351,853,455,0

58,256,6

3,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

min-max (mm)

Standard2LC120-R6G

Flanged3LC120-2R6G

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

kNmin

><

>< >> <<><k

(mm)l3

(mm)

><

><

Standard

2LC120-R6G 8,1 mm

6,2 mm

><

><

Flanged

3LC120-2R6G 10,0 mm

7,4 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 91: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

91

Stem : Steel | Head : Countersunk 90°

C120L® is a 8.8 grade small diameter LockBolt (improved version of C6L) with a semi-circular head, reducedand countersunkStandard stem and head (for a installation into non metallic materials)

C120L® R Lockbolt - Steel

6,6 - 6,8 16,9 19,1 10,2

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

6,4 12,1 2,9

43,11479,61481,21482,81484,41486,01487,61489,11490,71492,31493,91495,51497,11498,71500,31501,81503,41505,01506,61508,21509,81511,41513,01514,51516,11517,71519,31520,91522,51524,1

3,18 - 6,354,76 - 7,946,35 - 9,537,94 - 11,117,94 - 11,1111,11 - 14,2912,70 - 15,8814,29 - 17,4615,88 - 19,0517,46 - 20,6419,05 - 22,2320,64 - 23,8122,23 - 25,4023,81 - 26,9925,40 - 28,5826,99 - 30,1628,58 - 31,7530,16 - 33,3431,75 - 34,9333,34 - 36,5134,93 - 38,1036,51 - 39,6938,10 - 41,2839,69 - 42,8641,28 - 44,4542,86 - 46,0444,45 - 47,6346,04 - 49,21

49,21 - 52,3947,63 - 50,80

1,57 - 4,753,16 - 6,344,75 - 7,926,34 - 9,517,92 - 11,109,51 - 12,6911,10 - 14,2712,69 - 15,8614,27 - 17,4515,86 - 19,0417,45 - 20,6219,04 - 22,2120,62 - 23,8022,21 - 25,3923,80 - 26,9725,39 - 28,5626,97 - 30,1528,56 - 31,7430,15 - 33,3231,74 - 34,9133,32 - 36,5034,91 - 38,0936,50 - 39,6738,09 - 41,2639,67 - 42,8541,26 - 44,4442,85 - 46,0244,44 - 47,61

47,61 - 50,7946,02 - 49,20

C120L90-R8-3GC120L90-R8-4GC120L90-R8-5GC120L90-R8-6GC120L90-R8-7GC120L90-R8-8GC120L90-R8-9GC120L90-R8-10GC120L90-R8-11GC120L90-R8-12GC120L90-R8-13GC120L90-R8-14GC120L90-R8-15GC120L90-R8-16GC120L90-R8-17GC120L90-R8-18GC120L90-R8-19GC120L90-R8-20GC120L90-R8-21GC120L90-R8-22GC120L90-R8-23GC120L90-R8-24GC120L90-R8-25GC120L90-R8-26GC120L90-R8-27GC120L90-R8-28GC120L90-R8-29GC120L90-R8-30G

C120L90-R8-32GC120L90-R8-31G

14,516,117,619,220,822,424,025,627,228,830,331,933,535,136,738,339,941,543,044,646,247,849,451,052,654,255,7

58,960,5

57,3

3,24,86,47,99,511,112,714,315,917,519,120,622,223,825,427,028,630,231,833,334,936,538,139,741,342,944,546,0

49,247,6

>> <<><k

(mm)

min-max (mm)

Standard2LC120-R8G

Flanged3LC120-2R8G

><

l3(mm)

><

Standard

2LC120-R8G 10,6 mm

8,1 mm

><

><

Flanged

3LC120-2R8G 13,2 mm

9,6 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 92: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

92

Range of LockBolt®

C120L® is a 8.8 grade small diameter LockBolt (improved version of C6L) with a semi-circular head, reducedand countersunkStandard stem and head (for a installation into non metallic materials)

C120L® R Lockbolt - Steel

Stem : Steel | Head : Countersunk 90°

8,2 - 8,3 28,0 29,8 18,7

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

7,9 15,2 3,6

53,055,058,261,164,667,770,974,177,380,483,686,890,093,196,3

3,18 - 9,536,35 - 12,709,53 - 15,8812,70 - 19,0515,88 - 22,2319,05 - 25,4022,23 - 28,5825,40 - 31,7528,58 - 34,9331,75 - 38,1034,93 - 41,2838,10 - 44,4541,28 - 47,6344,45 - 50,8047,63 - 53,98

1,19 - 7,544,37 - 10,727,54 - 13,8910,72 - 17,0713,89 - 20,2417,07 - 23,4220,24 - 26,5923,42 - 29,7726,59 - 32,9429,77 - 36,1232,94 - 39,2936,12 - 42,4739,29 - 45,6442,47 - 48,8245,64 - 51,99

C120L90-R10-4GC120L90-R10-6GC120L90-R10-8GC120L90-R10-10GC120L90-R10-12GC120L90-R10-14GC120L90-R10-16GC120L90-R10-18GC120L90-R10-20GC120L90-R10-22GC120L90-R10-24GC120L90-R10-26GC120L90-R10-28GC120L90-R10-30GC120L90-R10-32G

20,924,127,230,433,636,839,943,146,349,552,655,859,062,264,2

4,36,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC120-R10G

Flanged3LC120-2R10G

><

l3(mm)

><

Standard

2LC120-R10G 12,8 mm

9,5 mm

><

><

Flanged

3LC120-2R10G 16,4 mm

10,8 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 93: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

93

Stem : Steel | Head : Countersunk 90°

C120L® is a 8.8 grade small diameter LockBolt (improved version of C6L) with a semi-circular head, reducedand countersunkStandard stem and head (for a installation into non metallic materials)

C120L® R Lockbolt - Steel

3,96 - 10,317,14 - 13,4910,31 - 16,6613,49 - 19,8416,66 - 23,0119,84 - 26,1623,01 - 29,3626,19 - 32,5429,36 - 35,7132,54 - 38,8935,71 - 42,0638,89 - 45,2442,06 - 48,4145,24 - 51,59

9,9 41,4 42,7 22,2

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

9,59,65 - 9,78 18,1 4,3

60,663,866,970,173,376,579,682,886,089,292,395,598,7101,9

6,35 - 12,709,53 - 15,8812,70 - 19,0515,88 - 22,2319,05 - 25,4022,23 - 28,5825,40 - 31,7528,58 - 34,9331,75 - 38,1034,93 - 41,2838,10 - 44,4541,28 - 47,6344,45 - 50,8047,63 - 53,98

C120L90-R12-6GC120L90-R12-8GC120L90-R12-10GC120L90-R12-12GC120L90-R12-14GC120L90-R12-16GC120L90-R12-18GC120L90-R12-20GC120L90-R12-22GC120L90-R12-24GC120L90-R12-26GC120L90-R12-28GC120L90-R12-30GC120L90-R12-32G

24,828,031,234,437,540,743,947,150,253,456,659,862,966,1

6,49,512,715,919,122,225,428,631,834,938,141,344,547,6

>> <<><k

(mm)

min-max (mm)

Standard2LC120-R12G

Flanged3LC120-2R12G

><

l3(mm)

><

Standard

2LC120-R12G 15,4 mm

11,9 mm

><

><

Flanged

3LC120-2R12G 19,7 mm

13,5 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 94: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

94

Range of LockBolt®

Fasteners suitable for extreme conditions8.8 grade large diameter LockBoltHigh resistance to vibrationsEasy visual inspection of the installation quality

C50L® Lockbolt - Steel

Stem : Steel | Head : Brazier

13,1 - 14,3 75,8 64,1 53,6

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

12,712,52 - 13,08 23,6 8,1

85,391,798,0104,4110,7117,1123,4129,8136,1142,5148,8155,2161,5167,9174,2180,6186,9193,3199,6206,0212,3218,7

6,4 - 12,712,7 - 19,119,1 - 25,425,4 - 31,831,8 - 38,138,1 - 44,544,5 - 50,850,8 - 57,257,2 - 63,563,5 - 69,969,9 - 76,276,2 - 82,682,6 - 88,988,9 - 95,395,3 - 101,6

3,2 - 9,59,5 - 15,915,9 - 22,222,2 - 28,628,6 - 34,934,9 - 41,341,3 - 47,647,6 - 54,054,0 - 60,360,3 - 66,766,7 - 73,073,0 - 79,479,4 - 85,785,7 - 92,192,1 - 98,4

C50LR-BR16-4C50LR-BR16-8C50LR-BR16-12C50LR-BR16-16C50LR-BR16-20C50LR-BR16-24C50LR-BR16-28C50LR-BR16-32C50LR-BR16-36C50LR-BR16-40C50LR-BR16-44C50LR-BR16-48C50LR-BR16-52C50LR-BR16-56C50LR-BR16-60

101,6 - 108,0108,0 - 114,3114,3 - 120,7120,7 - 127,0

98,4 - 104,8104,8 - 111,1111,1 - 117,5117,5 - 123,8

C50LR-BR16-64C50LR-BR16-68C50LR-BR16-72C50LR-BR16-76

127,0 - 133,4133,4 - 139,7139,7 - 146,1

123,8 - 130,2130,2 - 136,5136,5 - 142,9

C50LR-BR16-80C50LR-BR16-84C50LR-BR16-88

146,1 - 152,4 142,9 - 149,2C50LR-BR16-92

31,637,944,350,657,063,369,776,082,488,795,1101,4107,8114,1120,5

4,811,117,523,830,236,542,949,255,661,968,374,681,087,393,7100,0126,8106,4133,2112,7139,5119,1145,9125,4152,2131,8158,6138,1164,9144,5225,0 171,3

>> <<><k

(mm)

min-max (mm)

StandardLC-2R16G

Flanged3LC-2R16G

><

l3(mm)

><

Standard

LC-2R16G 20,5 mm

16,4 mm

><

><

Flanged

3LC-2R16G 26,4 mm

19,5 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 95: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

95

Fasteners suitable for extreme conditions8.8 grade large diameter LockBoltHigh resistance to vibrationsEasy visual inspection of the installation quality

C50L® Lockbolt - Steel

Stem : Steel | Head : Brazier

17,5 120,5 100,1 85,4

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

15,915,67 - 16,31 30,4 11,0

97,6104,0110,3116,7123,0129,4135,7142,1148,4154,8161,1167,5173,8180,2186,5192,9199,2205,6211,9218,3224,6231,0

6,4 - 12,712,7 - 19,119,1 - 25,425,4 - 31,831,8 - 38,138,1 - 44,544,5 - 50,850,8 - 57,257,2 - 63,563,5 - 69,969,9 - 76,276,2 - 82,682,6 - 88,988,9 - 95,395,3 - 101,6

2,3 - 8,68,6 - 15,115,1 - 21,421,4 - 27,827,8 - 34,134,1 - 40,540,5 - 46,846,8 - 53,253,2 - 59,559,5 - 65,965,9 - 72,272,2 - 78,678,6 - 84,984,9 - 91,391,3 - 97,6

C50LR-BR20-4C50LR-BR20-8C50LR-BR20-12C50LR-BR20-16C50LR-BR20-20C50LR-BR20-24C50LR-BR20-28C50LR-BR20-32C50LR-BR20-36C50LR-BR20-40C50LR-BR20-44C50LR-BR20-48C50LR-BR20-52C50LR-BR20-56C50LR-BR20-60

101,6 - 108,0108,0 - 114,3114,3 - 120,7120,7 - 127,0

97,6 - 104,0104,0 - 110,3110,3 - 116,7116,7 - 123,0

C50LR-BR20-64C50LR-BR20-68C50LR-BR20-72C50LR-BR20-76

127,0 - 133,4133,4 - 139,7139,7 - 146,1

123,0 - 129,4129,4 - 135,7135,7 - 142,1

C50LR-BR20-80C50LR-BR20-84C50LR-BR20-88

146,1 - 152,4 142,1 - 148,4C50LR-BR20-92

37,243,549,956,262,668,975,381,688,094,3100,7107,0113,4119,7126,1

4,811,117,523,830,236,542,949,255,661,968,374,681,087,393,7100,0132,4106,4138,8112,7145,1119,1151,5125,4157,8131,8164,2138,1170,5144,5237,3 176,9

>> <<><k

(mm)

min-max (mm)

StandardLC-2R20G

Flanged3LC-2R20G

><

l3(mm)

><

Standard

LC-2R20G 25,0 mm

21,8 mm

><

><

Flanged

3LC-2R20G 32,5 mm

24,6 mm

><

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 96: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

Fasteners suitable for extreme conditions8.8 grade large diameter LockBoltHigh resistance to vibrationsEasy visual inspection of the installation quality

C50L® Lockbolt - Steel

Stem : Steel | Head : Brazier

20,6 178,4 144,1 126,3

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

19,118,82 - 19,51 36,5 13,5

6,4 - 12,712,7 - 19,119,1 - 25,425,4 - 31,831,8 - 38,138,1 - 44,544,5 - 50,850,8 - 57,257,2 - 63,563,5 - 69,969,9 - 76,276,2 - 82,682,6 - 88,988,9 - 95,395,3 - 101,6

1,6 - 8,08,0 - 14,314,3 - 20,720,7 - 27,027,0 - 33,433,4 - 39,739,7 - 46,146,1 - 52,452,4 - 58,858,8 - 65,165,1 - 71,571,5 - 77,877,8 - 84,284,2 - 90,590,5 - 96,996,9 - 103,2

C50LR-BR24-4C50LR-BR24-8C50LR-BR24-12C50LR-BR24-16C50LR-BR24-20C50LR-BR24-24C50LR-BR24-28C50LR-BR24-32C50LR-BR24-36C50LR-BR24-40C50LR-BR24-44C50LR-BR24-48C50LR-BR24-52C50LR-BR24-56C50LR-BR24-60

101,6 - 108,0108,0 - 114,3114,3 - 120,7120,7 - 127,0

103,2 - 109,6109,6 - 115,9115,9 - 122,3122,3 - 128,6

C50LR-BR24-64C50LR-BR24-68C50LR-BR24-72C50LR-BR24-76

127,0 - 133,4133,4 - 139,7139,7 - 146,1

128,6 - 135,0135,0 - 141,3141,3 - 147,7

C50LR-BR24-80C50LR-BR24-84C50LR-BR24-88

146,1 - 152,4C50LR-BR24-92

39,345,752,058,464,771,177,483,890,196,5102,8109,2115,5121,9128,2

4,811,117,523,830,236,542,949,255,661,968,374,681,087,393,7100,0134,6106,4140,9112,7147,3119,1153,6125,4160,0131,8166,3138,1172,7144,5179,0

>> <<><k

(mm)

min-max (mm)

StandardLC-2R24G

Flanged3LC-2R24G

><

l3(mm)

110,3116,7123,0129,4135,7142,1148,4154,8161,1167,5173,8180,2186,5192,9199,2205,6211,9218,3224,6231,0237,3243,7250,0

><

Standard

LC-2R24G 30,1 mm

24,5 mm

><

><

Flanged

3LC-2R24G 38,7 mm

29,4 mm

><

96

Range of LockBolt®

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 97: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

Fasteners suitable for extreme conditions8.8 grade large diameter LockBoltHigh resistance to vibrationsEasy visual inspection of the installation quality

C50L® Lockbolt - Steel

Stem : Steel | Head : Brazier

23,8 246,7 193,1 174,6

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

22,2 42,1 14,7

12,7 - 19,119,1 - 25,425,4 - 31,831,8 - 38,138,1 - 44,544,5 - 50,850,8 - 57,257,2 - 63,563,5 - 69,969,9 - 76,276,2 - 82,682,6 - 88,988,9 - 95,395,3 - 101,6

7,1 - 13,513,5 - 19,919,9 - 26,226,2 - 32,632,6 - 38,938,9 - 45,345,3 - 51,651,6 - 58,058,0 - 64,364,3 - 70,770,7 - 77,077,0 - 83,483,4 - 89,789,7 - 96,1

C50LR-BR28-8C50LR-BR28-12C50LR-BR28-16C50LR-BR28-20C50LR-BR28-24C50LR-BR28-28C50LR-BR28-32C50LR-BR28-36C50LR-BR28-40C50LR-BR28-44C50LR-BR28-48C50LR-BR28-52C50LR-BR28-56C50LR-BR28-60

101,6 - 108,0108,0 - 114,3114,3 - 120,7120,7 - 127,0

96,1 - 102,4102,4 - 108,8108,8 - 115,1115,1 - 121,5

C50LR-BR28-64C50LR-BR28-68C50LR-BR28-72C50LR-BR28-76

127,0 - 133,4133,4 - 139,7139,7 - 146,1

121,5 - 127,8127,8 - 134,2134,2 - 140,5140,5 - 146,9

C50LR-BR28-80C50LR-BR28-84C50LR-BR28-88

146,1 - 152,4C50LR-BR28-92

49,656,062,368,775,081,487,794,1100,4106,8113,1119,5125,8132,2138,5

11,117,523,830,236,542,949,255,661,968,374,681,087,393,7100,0

144,9 106,4151,2 112,7157,6 119,1163,9 125,4170,3 131,8176,6 138,1183,0 144,5

>> <<><k

(mm)

min-max (mm)

StandardLC-2R28G

Flanged3LC-2R28G

12,7 - 25,419,1 - 31,825,4 - 38,131,8 - 44,538,1 - 50,844,5 - 57,250,8 - 63,557,2 - 69,963,5 - 76,269,9 - 82,676,2 - 88,982,6 - 95,388,9 - 101,695,3 - 108,0101,6 - 114,3108,0 - 120,7114,3 - 127,0120,7 - 133,4127,0 - 139,7133,4 - 146,1139,7 - 152,4146,1 - 158,8

Low Profile8LC-2R28G

><

l3(mm)

123,9130,2136,6142,9149,3155,6162,0168,3174,7181,0187,4193,7200,1206,4212,8219,1225,5231,8238,2244,5250,9257,2

><

Standard

LC-2R28G 35,1 mm

28,5 mm

><

><

Flanged

3LC-2R28G 41,1 mm

34,1 mm

><

><

Low Profile

8LC-2R28G 25,1 mm

17,4 mm

><

97

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 98: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

Fasteners suitable for extreme conditions8.8 grade large diameter LockBoltHigh resistance to vibrationsEasy visual inspection of the installation quality

C50L® Lockbolt - Steel

Stem : Steel | Head : Brazier

27,0 323,4 251,3 229,1

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

25,4 50,8 16,5

12,7 - 19,119,1 - 25,425,4 - 31,831,8 - 38,138,1 - 44,544,5 - 50,850,8 - 57,257,2 - 63,563,5 - 69,969,9 - 76,276,2 - 82,682,6 - 88,988,9 - 95,395,3 - 101,6

C50LR-BR32-8C50LR-BR32-12C50LR-BR32-16C50LR-BR32-20C50LR-BR32-24C50LR-BR32-28C50LR-BR32-32C50LR-BR32-36C50LR-BR32-40C50LR-BR32-44C50LR-BR32-48C50LR-BR32-52C50LR-BR32-56C50LR-BR32-60

101,6 - 108,0108,0 - 114,3114,3 - 120,7120,7 - 127,0

C50LR-BR32-64C50LR-BR32-68C50LR-BR32-72C50LR-BR32-76

127,0 - 133,4133,4 - 139,7139,7 - 146,1

C50LR-BR32-80C50LR-BR32-84C50LR-BR32-88

146,1 - 152,4

6,4 - 12,712,7 - 19,119,1 - 25,425,4 - 31,831,8 - 38,138,1 - 44,544,5 - 50,850,8 - 57,257,2 - 63,563,5 - 69,969,9 - 76,276,2 - 82,682,6 - 88,988,9 - 95,395,3 - 101,6101,6 - 108,0108,0 - 114,3114,3 - 120,7120,7 - 127,0127,0 - 133,4133,4 - 139,7139,7 - 146,1C50LR-BR32-92

53,960,366,673,079,385,792,098,4104,7111,1117,4123,8130,1136,5142,8149,2155,5161,9168,2174,6180,9187,3

>> <<><k

(mm)

min-max (mm)

StandardLC-2R32G

Flanged3LC-2R32G

><

l3(mm)

141,6148,0154,3160,7167,0173,4179,7186,1192,4198,8205,1211,5217,8224,2230,5236,9243,2249,6255,9262,3268,6275,0

11,117,523,830,236,542,949,255,661,968,374,681,087,393,7100,0106,4112,7119,1125,4131,8138,1144,5

><

Standard

LC-2R32G 40,0 mm

32,6 mm

><

><

Flanged

3LC-2R32G 48,3 mm

38,7 mm

><

98

Range of LockBolt®

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 99: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

Fasteners suitable for extreme conditions8.8 grade large diameter LockBoltHigh resistance to vibrationsEasy visual inspection of the installation quality

C50L® Lockbolt - Steel

Stem : Steel | Head : Brazier

C50LR-BR36-28C50LR-BR36-32C50LR-BR36-36C50LR-BR36-40C50LR-BR36-44C50LR-BR36-48C50LR-BR36-52C50LR-BR36-56C50LR-BR36-60C50LR-BR36-64C50LR-BR36-68C50LR-BR36-72C50LR-BR36-76C50LR-BR36-80C50LR-BR36-84C50LR-BR36-88C50LR-BR36-92

30,2 369,0 309,2 260,0

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

28,6 54,1 18,4

41,3 - 54,047,6 - 60,354,0 - 66,760,3 - 73,066,7 - 79,473,0 - 85,779,4 - 92,185,7 - 98,492,1 - 104,898,4 - 111,1104,8 - 117,5111,1 - 123,8117,5 - 130,2123,8 - 136,5130,2 - 142,9136,5 - 149,2142,9 - 155,6

90,296,5102,9109,2115,6121,9128,3134,6141,0147,3153,7160,0166,4172,7179,1185,4191,8

>> <<><k

(mm)

min-max (mm)

StandardLC-2R36G

><

l3(mm)

178,1184,5190,8197,2203,5209,9216,2222,6228,9235,3241,6248,0254,3260,7267,0273,4279,7

40,847,253,559,966,272,678,985,391,698,0104,3110,7117,0123,4129,7136,1142,4

><

Standard

LC-2R36G 45,1 mm

36,7 mm

><

99

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

Page 100: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

Fasteners suitable for extreme conditions8.8 grade large diameter LockBoltHigh resistance to vibrationsEasy visual inspection of the installation quality

C50L® Lockbolt - Stainless steel

Stem : Stainless steel | Head : Brazier

13,1 - 14,3 75,8 61,8 53,6

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

12,712,52 - 13,08 23,6 8,1

85,391,798,0104,4110,7117,1

3,2 - 6,49,5 - 12,715,9 - 19,122,2 - 25,428,6 - 31,834,9 - 38,1

C50LR-U16-4C50LR-U16-8C50LR-U16-12C50LR-U16-16C50LR-U16-20C50LR-U16-24

31,637,944,350,657,063,3

4,811,117,523,830,236,5

>> <<><k

(mm)

min-max (mm)

Flanged3LC-2CU16

><

l3(mm)

><

Flanged

3LC-2CU16 48,3 mm

38,7 mm

><

100

Range of LockBolt®

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 101: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

Fasteners suitable for extreme conditions8.8 grade large diameter LockBoltHigh resistance to vibrationsEasy visual inspection of the installation quality

C50L® Lockbolt - Inox

Stem : Stainless steel | Head : Brazier

97,6104,0110,3116,7123,0129,4

C50LR-U20-4C50LR-U20-8C50LR-U20-12C50LR-U20-16C50LR-U20-20C50LR-U20-24

37,243,549,956,262,668,9

4,811,117,523,830,236,5

17,5 120,5 93,4 85,4

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

15,915,67 -16,31

30,4 11,0

2,3 - 6,48,7 - 12,715,1 - 19,121,4 - 25,427,8 - 31,834,1 - 38,1

>> <<><k

(mm)

min-max (mm)

Flanged3LC-2CU20

><

l3(mm)

><

Flanged

3LC-2CU20 41,1 mm

34,1 mm

><

101

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 102: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

Fasteners suitable for extreme conditions8.8 grade large diameter LockBoltHigh resistance to vibrationsEasy visual inspection of the installation quality

C50L® Lockbolt - Steel

Stem : Steel | Head : Countersunk 90°

13,1 - 14,3 75,8 64,1 53,6

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

12,712,52 - 13,08 24,1 6,5

91,798,0104,4110,7117,1123,4129,8136,1142,5148,8155,2161,5167,9174,2180,6

12,7 - 19,119,1 - 25,425,4 - 31,831,8 - 38,138,1 - 44,544,5 - 50,850,8 - 57,257,2 - 63,563,5 - 69,969,9 - 76,276,2 - 82,682,6 - 88,988,9 - 95,395,3 - 101,6

9,5 - 15,915,9 - 22,222,2 - 28,628,6 - 34,934,9 - 41,341,3 - 47,647,6 - 54,054,0 - 60,360,3 - 66,766,7 - 73,073,0 - 79,479,4 - 85,785,7 - 92,192,1 - 98,4

C50L90-BR16-8C50L90-BR16-12C50L90-BR16-16C50L90-BR16-20C50L90-BR16-24C50L90-BR16-28C50L90-BR16-32C50L90-BR16-36C50L90-BR16-40C50L90-BR16-44C50L90-BR16-48C50L90-BR16-52C50L90-BR16-56C50L90-BR16-60

101,6 - 108,0 98,4 - 104,8C50L90-BR16-64

37,944,350,657,063,369,776,082,488,795,1101,4107,8114,1120,5

11,117,523,830,236,542,949,255,661,968,374,681,087,393,7100,0126,8

>> <<><k

(mm)

min-max (mm)

StandardLC-2R16G

Flanged3LC-2R16G

l3(mm)

><

><

Standard

LC-2R16G 20,5 mm

16,4 mm

><

><

Flanged

3LC-2R16G 26,4 mm

19,5 mm

><

102

Range of LockBolt®

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 103: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

Fasteners suitable for extreme conditions8.8 grade large diameter LockBoltHigh resistance to vibrationsEasy visual inspection of the installation quality

C50L® Lockbolt - Steel

Stem : Steel | Head : Countersunk 90°

104,0110,3116,7123,0129,4135,7142,1148,4154,8161,1167,5173,8180,2186,5192,9

12,7 - 19,119,1 - 25,425,4 - 31,831,8 - 38,138,1 - 44,544,5 - 50,850,8 - 57,257,2 - 63,563,5 - 69,969,9 - 76,276,2 - 82,682,6 - 88,988,9 - 95,395,3 - 101,6

C50L90-BR20-8C50L90-BR20-12C50L90-BR20-16C50L90-BR20-20C50L90-BR20-24C50L90-BR20-28C50L90-BR20-32C50L90-BR20-36C50L90-BR20-40C50L90-BR20-44C50L90-BR20-48C50L90-BR20-52C50L90-BR20-56C50L90-BR20-60

101,6 - 108,0C50L90-BR20-64

43,549,956,262,668,975,381,688,094,3100,7107,0113,4119,7126,1

11,117,523,830,236,542,949,255,661,968,374,681,087,393,7100,0132,4

17,5 120,5 100,1 85,4

Ø(mm)

d1(mm)

l(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

15,915,67 -16,31

30,2 8,0

8,6 - 15,115,1 - 21,421,4 - 27,827,8 - 34,134,1 - 40,540,5 - 46,846,8 - 53,253,2 - 59,559,5 - 65,965,9 - 72,272,2 - 78,678,6 - 84,984,9 - 91,391,3 - 97,697,6 - 104,0

k(mm)

min-max (mm)

StandardLC-2R20G

Flanged3LC-2R20G

><

><d2(mm)

><><

l3(mm)

> <

><

Standard

LC-2R20G 25,0 mm

21,8 mm

><

><

Flanged

3LC-2R20G 32,5 mm

24,6 mm

><

103

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 104: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

Fasteners suitable for extreme conditions8.8 grade large diameter LockBoltHigh resistance to vibrationsEasy visual inspection of the installation quality

C50L® Lockbolt - Steel

Stem : Steel | Head : Countersunk 90°

20,7 178,4 144,1 126,3

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

Clampload

kNkNmin

><

><

19,118,82 - 19,51 36,1 9,6

19,1 - 25,425,4 - 31,831,8 - 38,138,1 - 44,544,5 - 50,850,8 - 57,257,2 - 63,563,5 - 69,969,9 - 76,276,2 - 82,682,6 - 88,988,9 - 95,395,3 - 101,6

C50L90-BR24-12C50L90-BR24-16C50L90-BR24-20C50L90-BR24-24C50L90-BR24-28C50L90-BR24-32C50L90-BR24-36C50L90-BR24-40C50L90-BR24-44C50L90-BR24-48C50L90-BR24-52C50L90-BR24-56C50L90-BR24-60

101,6 - 108,0C50L90-BR24-64

>> <<><k

(mm)

min-max (mm)

StandardLC-2R24G

Flanged3LC-2R24G

l3(mm)

><

52,058,464,771,177,483,890,196,5102,8109,2115,5121,9128,2

17,523,830,236,542,949,255,661,968,374,681,087,393,7100,0134,6

123,0129,4135,7142,1148,4154,8161,1167,5173,8180,2186,5192,9199,2205,6

14,3 - 20,720,7 - 27,027,0 - 33,433,4 - 39,739,7 - 46,146,1 - 52,452,4 - 58,858,8 - 65,165,1 - 71,571,5 - 77,877,8 - 84,284,2 - 90,590,5 - 96,996,9 - 103,2

><

Standard

LC-2R24G 30,1 mm

24,5 mm

><

><

Flanged

3LC-2R24G 38,7 mm

29,4 mm

><

104

Range of LockBolt®

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Minimum shear strength - = Min. and Max. grip range

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

Page 105: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

105

Designed specifically for joining composite board in trailer applications.Will not crush or damage the composite platesIntegral seal around pin head prevents moisture ingressNo bulge on both sides after the installation

Hucktainer® - Steel

Stem : Steel | Head : Standard low profile head

10,7 3,6

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

><><

9,5 21,2 3,457,258,8

HLPSG-R12-8HLPSG-R12-9

14,416,0

3,24,8

>> <<><k

(mm)

Short gripclearance

HLPSGC-R12

Short gripmedium

HLPSGM-R12

Short gripwide bearingHLPSGS-R12

><

l3(mm)

11,1 - 14,312,7 - 15,9

Short gripclearanceHLPSGC-R12

Short gripmedium

HLPSGM-R12

Short gripwide bearingHLPSGS-R12

> <

16,2 mm

5,2 mm

><

23,8 mm

5,1 mm

><

29,6 mm

5,2 mm

><> <

> <

min-max (mm)

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Min. and Max. grip range

>

>

Page 106: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

106

Range of LockBolt®

Designed specifically for joining composite board in trailer applications.Will not crush or damage the composite platesIntegral seal around pin head prevents moisture ingressNo bulge on both sides after the installation

Hucktainer® - Steel

Stem : Steel | Head : Standard low profile head

10,7 3,6

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

><><

9,5 21,2 3,4

58,560,161,763,264,866,468,069,671,272,874,475,977,579,180,782,383,985,587,188,690,2

15,88 - 17,4617,46 - 19,0519,05 - 20,6320,63 - 22,2222,22 - 23,8123,81 - 25,4025,40 - 26,9826,98 - 28,5728,57 - 30,1630,16 - 31,7531,75 - 33,3333,33 - 34,9234,92 - 36,5136,51 - 38,1038,10 - 39,68

HLPPLS-R12-10HLPPLS-R12-11HLPPLS-R12-12HLPPLS-R12-13HLPPLS-R12-14HLPPLS-R12-15HLPPLS-R12-16HLPPLS-R12-17HLPPLS-R12-18HLPPLS-R12-19HLPPLS-R12-20HLPPLS-R12-21HLPPLS-R12-22HLPPLS-R12-23HLPPLS-R12-24

16,017,619,220,822,424,025,527,128,730,331,933,535,136,738,239,841,443,044,646,247,8

3,24,05,66,78,810,411,913,515,116,718,3

19,9

>> <<><k

(mm)

min-max (mm)

Flat

HLPS-R12XA

Clearance

HLPSC-R12

Mediumbearing

HLPSM-R12

39,68 - 41,27HLPPLS-R12-2541,27 - 42,86HLPPLS-R12-2642,86 - 44,45HLPPLS-R12-2744,45 - 46,03HLPPLS-R12-2846,03 - 47,62HLPPLS-R12-2947,62 - 49,21HLPPLS-R12-30

Widebearing

HLPS-R12

><

l3(mm)

14,30 - 17,5015,90 - 19,0517,50 - 20,6319,00 - 22,2220,60 - 23,8122,20 - 25,4023,80 - 27,0025,40 - 28,6027,00 - 30,2028,60 - 31,7530,20 - 33,3331,70 - 34,9233,30 - 36,5134,90 - 38,1036,50 - 39,7038,10 - 41,3039,70 - 42,9041,30 - 44,4542,90 - 46,0344,40 - 47,6246,00 - 49,21

> <

> <

FlatHLPS-R12XA

29,4 mm

2,0 mm

><

ClearanceHLPSC-R12

16,1 mm

3,7 mm

><

Standard moyenneHLPSM-R12

23,8 mm

3,8 mm

><

Standard largeHLPS-R12

29,6 mm

3,7 mm

><> <

> <

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Min. and Max. grip range

>

>

Page 107: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

107

Designed specifically for joining composite board in trailer applications.Will not crush or damage the composite platesIntegral seal around pin head prevents moisture ingressNo bulge on both sides after the installation

Hucktainer® - Steel

Stem : Steel | Head : Medium bearing colour encapsulated

10,7 3,6

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

><><

9,5 24,1 7,3

54,856,458,059,661,162,764,365,967,569,170,772,373,875,477,078,680,281,883,485,086,5

15,88 - 17,4617,46 - 19,0519,05 - 20,6320,63 - 22,2222,22 - 23,8123,81 - 25,4025,40 - 26,9826,98 - 28,5728,57 - 30,1630,16 - 31,7531,75 - 33,3333,33 - 34,9234,92 - 36,5136,51 - 38,1038,10 - 39,68

14,30 - 17,5015,90 - 19,0517,50 - 20,6319,00 - 22,2220,60 - 23,8122,20 - 25,4023,80 - 27,0025,40 - 28,6027,00 - 30,2028,60 - 31,7530,20 - 33,3331,70 - 34,9233,30 - 36,5134,90 - 38,1036,50 - 39,70

HLPMG-R12-10HLPMG-R12-11HLPMG-R12-12HLPMG-R12-13HLPMG-R12-14HLPMG-R12-15HLPMG-R12-16HLPMG-R12-17HLPMG-R12-18HLPMG-R12-19HLPMG-R12-20HLPMG-R12-21HLPMG-R12-22HLPMG-R12-23HLPMG-R12-24

14,015,617,218,820,321,923,525,126,728,329,931,533,034,636,237,839,441,042,644,245,7

2,03,65,26,88,410,011,513,114,716,317,919,521,322,724,225,827,429,030,632,233,8

>> <<><k

(mm)

39,68 - 41,27 38,10 - 41,30HLPMG-R12-2541,27 - 42,86 39,70 - 42,90HLPMG-R12-2642,86 - 44,45 41,30 - 44,45HLPMG-R12-2744,45 - 46,03 42,90 - 46,03HLPMG-R12-2846,03 - 47,62 44,40 - 47,62HLPMG-R12-2947,62 - 49,21 46,00 - 49,21HLPMG-R12-30

><

l3(mm)

Flat

HLPS-R12XA

Clearance

HLPSC-R12

Mediumbearing

HLPSM-R12

Widebearing

HLPS-R12

> <

> <

FlatHLPS-R12XA

29,4 mm

2,0 mm

><

ClearanceHLPSC-R12

16,1 mm

3,7 mm

><

Standard moyenneHLPSM-R12

23,8 mm

3,8 mm

><

Standard largeHLPS-R12

29,6 mm

3,7 mm

><> <

> <

min-max (mm)

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Min. and Max. grip range

>

>

Page 108: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

108

Range of LockBolt®

Designed specifically for joining composite board in trailer applications.Will not crush or damage the composite platesIntegral seal around pin head prevents moisture ingressNo bulge on both sides after the installation

Hucktainer® - Steel

Stem : Steel | Head : Wide bearing colour encapsulated

10,7 3,6

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

><><

9,5 30,7 6,655,657,1

HLPEG-R12-7HLPEG-R12-8

12,814,3

1,3

56,8 HLPEG-R12-914,3 1,32,8

>> <<><k

(mm)

Clearance

HLPSGC-R12

Medium bearing

HLPSGM-R12

Wide bearing

HLPSGS-R12

><

l3(mm)

9,5 - 12,7

12,7 - 15,911,1 - 14,3

Clearance

HLPSGC-R12

Medium bearing

HLPSGM-R12

Wide bearing

HLPSGS-R12

> <

16,2 mm

5,2 mm

><

23,8 mm

5,1 mm

><

29,6 mm

5,2 mm

><> <

> <

min-max (mm)

>

>

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Min. and Max. grip range

>

>

Page 109: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

109

Designed specifically for joining composite board in trailer applications.Will not crush or damage the composite platesIntegral seal around pin head prevents moisture ingressNo bulge on both sides after the installation

Hucktainer® - Steel

Stem : Steel | Head : Wide bearing colour encapsulated

10,7 3,6

Ø(mm)

d1(mm)

l(mm)

d2(mm)

l2(mm)

kNmin

><><

9,5 30,7 6,6

58,460,061,663,264,866,367,969,571,172,774,375,977,579,080,682,283,885,487,088,6

15,88 - 17,4617,46 - 19,0519,05 - 20,6320,63 - 22,2222,22 - 23,8123,81 - 25,4025,40 - 26,9826,98 - 28,5728,57 - 30,1630,16 - 31,7531,75 - 33,3333,33 - 34,9234,92 - 36,5136,51 - 38,1038,10 - 39,68

14,30 - 17,5015,90 - 19,0517,50 - 20,6319,00 - 22,2220,60 - 23,8122,20 - 25,4023,80 - 27,0025,40 - 28,6027,00 - 30,2028,60 - 31,7530,20 - 33,3331,70 - 34,9233,30 - 36,5134,90 - 38,1036,50 - 39,70

HLPEG-R12-10HLPEG-R12-11HLPEG-R12-12HLPEG-R12-13HLPEG-R12-14HLPEG-R12-15HLPEG-R12-16HLPEG-R12-17HLPEG-R12-18HLPEG-R12-19HLPEG-R12-20HLPEG-R12-21HLPEG-R12-22HLPEG-R12-23HLPEG-R12-24

15,917,519,120,722,323,925,527,028,630,231,833,435,036,638,239,741,342,944,546,1

2,03,65,26,88,410,011,513,114,716,317,919,521,322,724,225,827,429,030,632,2

>> <<><k

(mm)

39,68 - 41,27 38,10 - 41,30HLPEG-R12-2541,27 - 42,86 39,70 - 42,90HLPEG-R12-2642,86 - 44,45 41,30 - 44,45HLPEG-R12-2744,45 - 46,03 42,90 - 46,03HLPEG-R12-2846,03 - 47,62 44,40 - 47,62HLPEG-R12-29

><

l3(mm)

Flat

HLPS-R12XA

Clearance

HLPSC-R12

Mediumbearing

HLPSM-R12

Widebearing

HLPS-R12

> <

> <

FlatHLPS-R12XA

29,4 mm

2,0 mm

><

ClearanceHLPSC-R12

16,1 mm

3,7 mm

><

Medium bearingHLPSM-R12

23,8 mm

3,8 mm

><

Wide bearingHLPS-R12

29,6 mm

3,7 mm

><> <

> <

min-max (mm)

>

>

The articles codes in bluecorrespond to the core range(most commonly used references)

d1 = Diameter - I = Length of the stem - I2 = Position of the breakneck groove - I3 = Length without grooves

Ø = Hole diameter - k = Head thickness - d2 = Head diameter - = Minimum tensile strength

= Min. and Max. grip range

>

>

Page 110: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

110

Range of LockBolt®

BobTail® system:the most advanced development in LockBolts

The BobTail® system is composed of LockBolt and associated installation tooling and has been developed toensure the highest levels of profitability and reliability.

Main advantages:

� A quick installation cycle.The installation speed of a BobTail® with a diameter of 6.4 mm is less than one second.The BobTail®, 16 mm in diameter, is installed in 2 seconds: up to 2 times faster than any other LockBoltavailable on the market.

� No breaking of the riveting stem:- reduced wastage,- low installation noise- increased corrosion resistance

� A fluid installation sequence and without any fuss, eliminating the physical constraints imposed to the operator.

� High resistance to wear and vibration.

� Unique helical lock groove (12 mm diameter and superior). Holds the collar on the stem prior to installation.

� No secondary operations.

� A quick visual inspection enable to check that the installation has been properly done (12 mm diameterand superior).

� If you are currently using HUCK® Lockbolts such as the C50L® or C6L®, you can easily switch to BobTail® toget its benefits. Indeed, the changes are simple and quick, it is only necessary to adapt the nose assemblyof the tooling.

Before installation After installation

Page 111: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

111

Diameters available: 12mm, 14mm, 16mm and 20mmDifferent surface treatments with various corrosion resistance are available on request.

Standard and quality head types:

BrazierStandard of 5 grade

Available in 8.8 grade (Ø > 12.7 mm)

Countersunk 90°On request

Resistance values Ibf (kN)

BobTail® installation tools

BobTail® tools allow a simpler and faster installation process than a conventional LockBolt system, thanks toa reduced setting force.

The installation tools are lighter and more compact and offer a greater flexibility of use.

The installation process is simple and helps to extend the lifetime of the tool and spare parts.In this way, the maintenance and tooling costs are reduced significantly, and increase productivity.

Brazier head Flanged head

Imperial dimensions 5 grade (Ø 3/16 to 3/8)8.8 grade (Ø 1/2 to 1) –

Metric dimensions – 10.9 grade(Ø 12 to 20mm)

12 mm. (10.9) 14.700 (65,4) 19.700 (87,7)

Diameter Clamp load Tensile Shear

18.500 (65,4)

14 mm. (10.9) 19.500 (87) 27.000 (120) 21.100 (94)

16 mm. (10.9) 26.000 (116) 36.600 (163) 26.000 (116)

20 mm. (10.9) 40.700 (181) 57.300 (255) 41.000 (182)

FlangedStandard of 10.9 grade

Metric range

BOBTAIL® SWAGEFORWARDriveting machine

BOBTAIL® BTTriveting machine

Page 112: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

112

Range of LockBolt®

No breaking of the riveting stem: increased corrosion resistance, reduced wastage, low installation noiseA better support provided by the collar and the head of the rivetSemi-automatic tooling installation: more accurate and rapidity in the installationUnique helical lock groove: Holds the collar on the stem prior to installationZinc collar / stem uncoated (add suffix "G" to the reference for the zinc stem)

BobTail® - Steel - Metric dimensions

Stem : Steel | Head : Flanged

12,0 - 13,5

5,0 - 15,0

87,7 65,4 64,9

Ø(mm)

d1(mm)

l(mm)

l2(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

><

><

12,0 25,43,8

9,5

9,6

MBT-DT12-1046,110,0 - 20,0 MBT-DT12-1551,115,0 - 25,0 MBT-DT12-2056,120,0 - 30,0 MBT-DT12-2561,125,0 - 35,0 MBT-DT12-3066,130,0 - 40,0 MBT-DT12-3571,135,0 - 45,0 MBT-DT12-4076,140,0 - 50,045,0 - 55,050,0 - 60,055,0 - 65,0

MBT-DT12-45MBT-DT12-50MBT-DT12-55MBT-DT12-60

81,186,191,196,1

60,0 - 70,0 MBT-DT12-65101,1

75,0 - 85,0 MBT-DT12-80116,1

65,0 - 75,0 MBT-DT12-70106,170,0 - 80,0 MBT-DT12-75

MBTC-R12BL

111,1

> <> <k

(mm)

Clampload

kN

Ref.of the collar>

<

><

MBTC-R12BL 12,3 mm

17,9 mm

><

d1 = Diameter - I = Length of the stem - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

The articles codes in bluecorrespond to the core range(most commonly used references)

>>

Page 113: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

d1 = Diameter - I = Length of the stem - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

113

No breaking of the riveting stem: increased corrosion resistance, reduced wastage, low installation noiseA better support provided by the collar and the head of the rivetSemi-automatic tooling installation: more accurate and rapidity in the installationUnique helical lock groove: Holds the collar on the stem prior to installationZinc collar / stem uncoated (add suffix "G" to the reference for the zinc stem)

BobTail® - Steel - Metric dimensions

Stem : Steel | Head : Flanged

14,0 - 15,5

5,0 - 15,0

120,0 94,0 87,0

Ø(mm)

d1(mm)

l(mm)

l2(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

><

><

14,0 30,03,8

9,5

11,5

MBT-DT14-1049,010,0 - 20,0 MBT-DT14-1554,015,0 - 25,0 MBT-DT14-2059,020,0 - 30,0 MBT-DT14-2564,025,0 - 35,0 MBT-DT14-3069,030,0 - 40,0 MBT-DT14-3574,035,0 - 45,0 MBT-DT14-4079,040,0 - 50,045,0 - 55,050,0 - 60,055,0 - 65,0

MBT-DT14-45MBT-DT14-50MBT-DT14-55MBT-DT14-60

84,089,094,099,0

60,0 - 70,0 MBT-DT14-65104,0

75,0 - 85,0 MBT-DT14-80119,0

65,0 - 75,0 MBT-DT14-70109,070,0 - 80,0 MBT-DT14-75

MBTC-R14BL

114,0

> <> <k

(mm)

Clampload

kN

Ref.of the collar>

<

><

MBTC-R14BL 14,4 mm

22,1 mm

><

The articles codes in bluecorrespond to the core range(most commonly used references)

>>

Page 114: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

114

Range of LockBolt®

No breaking of the riveting stem: increased corrosion resistance, reduced wastage, low installation noiseA better support provided by the collar and the head of the rivetSemi-automatic tooling installation: more accurate and rapidity in the installationUnique helical lock groove: Holds the collar on the stem prior to installationZinc collar / stem uncoated (add suffix "G" to the reference for the zinc stem)

BobTail® - Steel - Metric dimensions

Stem : Steel | Head : Flanged

16,0 - 17,5

5,0 - 15,0

163,00 122,0 116,0

Ø(mm)

d1(mm)

l(mm)

l2(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

><

><

16,0 33,8

3,8

9,5

12,2

MBT-DT16-1052,010,0 - 20,0 MBT-DT16-1557,015,0 - 25,0 MBT-DT16-2062,020,0 - 30,0 MBT-DT16-2567,025,0 - 35,0 MBT-DT16-3072,030,0 - 40,0 MBT-DT16-3577,035,0 - 45,0 MBT-DT16-4082,040,0 - 50,045,0 - 55,050,0 - 60,055,0 - 65,0

MBT-DT16-45MBT-DT16-50MBT-DT16-55MBT-DT16-60

87,092,097,0102,0

60,0 - 70,0 MBT-DT16-65107,0

75,0 - 85,0 MBT-DT16-80122,0

65,0 - 75,0 MBT-DT16-70112,070,0 - 80,0 MBT-DT16-75

MBTC-R16BL

117,0

> <> <k

(mm)

Clampload

kN

Ref.of the collar>

<

><

MBTC-R16BL 16,4 mm

23,7 mm

><

d1 = Diameter - I = Length of the stem - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

The articles codes in bluecorrespond to the core range(most commonly used references)

>>

Page 115: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

115

No breaking of the riveting stem: increased corrosion resistance, reduced wastage, low installation noiseA better support provided by the collar and the head of the rivetSemi-automatic tooling installation: more accurate and rapidity in the installationUnique helical lock groove: Holds the collar on the stem prior to installationZinc collar / stem uncoated (add suffix "G" to the reference for the zinc stem)

BobTail® - Steel - Metric dimensions

Stem : Steel | Head : Flanged

20,0 - 22,0

5,0 - 15,0

255,0 191,0 181,0

Ø(mm)

d1(mm)

l(mm)

l2(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

><

><

20,0 42,4

3,8

9,5

16,0

MBT-DT20-1060,710,0 - 20,0 MBT-DT20-1565,715,0 - 25,0 MBT-DT20-2070,720,0 - 30,0 MBT-DT20-2575,725,0 - 35,0 MBT-DT20-3080,730,0 - 40,0 MBT-DT20-3585,735,0 - 45,0 MBT-DT20-4090,740,0 - 50,045,0 - 55,050,0 - 60,055,0 - 65,0

MBT-DT20-45MBT-DT20-50MBT-DT20-55MBT-DT20-60

95,7100,7105,7110,7

60,0 - 70,0 MBT-DT20-65115,7

75,0 - 85,0 MBT-DT20-80130,7

65,0 - 75,0 MBT-DT20-70120,770,0 - 80,0 MBT-DT20-75

MBTC-R20BL

125,7

> <> <k

(mm)

Clampload

kN

Ref.of the collar>

<

><

MBTC-R20BL 20,5 mm

29,6 mm

><

d1 = Diameter - I = Length of the stem - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

The articles codes in bluecorrespond to the core range(most commonly used references)

>>

Page 116: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

116

Range of LockBolt®

No breaking of the riveting stem: increased corrosion resistance, reduced wastage, low installation noiseA better support provided by the collar and the head of the rivetSemi-automatic tooling installation: more accurate and rapidity in the installationUnique helical lock groove: holds the collar on the stem prior to installation8,8 grade on request

BobTail® - Steel - Imperial dimensions

Stem : Steel | Head : Brazier

6,4 - 7,1

0,0 - 4,7

13,3 13,6 8,0

Ø(mm)

d1(mm)

l(mm)

l2(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

><

><

1/4(6,4 mm)

13,6 3,6

BT-R8-1GA20,70,0 - 6,4 BT-R8-2GA22,21,6 - 7,9 BT-R8-3GA23,83,2 - 9,5 BT-R8-4GA25,44,7 - 11,1 BT-R8-5GA27,06,4 - 12,7 BT-R8-6GA28,69,5 - 15,9 BT-R8-8GA30,212,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,6

BT-R8-10GABT-R8-12GABT-R8-14GABT-R8-16GA

31,833,334,936,5

25,4 - 31,8 BT-R8-18GA38,128,6 - 34,9 BT-R8-20GA39,7

1,01,63,24,76,47,911,114,317,420,623,827,030,1

BTC-R8GA/GAH

> <> <k

(mm)

Clampload

kN

Ref.of the collar>

<

><

BTC-R8GA/GAH 13,3 mm

9,7 mm

><

d1 = Diameter - I = Length of the stem - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>>

Page 117: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

117

No breaking of the riveting stem: increased corrosion resistance, reduced wastage, low installation noiseA better support provided by the collar and the head of the rivetSemi-automatic tooling installation: more accurate and rapidity in the installationUnique helical lock groove: holds the collar on the stem prior to installation8,8 grade on request

BobTail® - Steel - Imperial dimensions

Stem : Steel | Head : Brazier

7,9 - 9,1 20,5 21,0 12,5

Ø(mm)

d1(mm)

l(mm)

l2(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

><

><

5/16(7,9 mm)

17,3 4,4

29,432,535,7

3,2 - 9,5 BT-R10-4GA

38,942,1

6,4 - 12,7 BT-R10-6GA

45,2

9,5 - 15,9 BT-R10-8GA

48,4

12,7 - 19,115,9 - 22,219,1 - 25,422,2 - 28,6

BT-R10-10GABT-R10-12GABT-R10-14GABT-R10-16GA

51,654,8

25,4 - 31,8 BT-R10-18GA28,6 - 34,9 BT-R10-20GA

4,77,911,114,317,420,623,827,030,1

BTC-R10GA/GAH

> <> <k

(mm)

Clampload

kN

Ref.of the collar>

<

><

BTC-R10GA/GAH 16,3 mm

12,1 mm

><

d1 = Diameter - I = Length of the stem - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>>

Page 118: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

118

Range of LockBolt®

No breaking of the riveting stem: increased corrosion resistance, reduced wastage, low installation noiseA better support provided by the collar and the head of the rivetSemi-automatic tooling installation: more accurate and rapidity in the installationUnique helical lock groove: holds the collar on the stem prior to installation8,8 grade on request

BobTail® - Steel - Imperial dimensions

Stem : Steel | Head : Brazier

9,5 - 10,7

3,2 - 9,5

28,9Voir note 1

5,3Voir note 1

17,9Voir note 1

Ø(mm)

d1(mm)

l(mm)

l2(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

><

><

3/8(9,5 mm)

20,83 5,3

BT-R12-4GA33,36,4 - 12,7 BT-R12-6GA36,59,5 - 15,9 BT-R12-8GA39,612,7 - 19,1 BT-R12-10GA42,815,9 - 22,2 BT-R12-12GA46,019,1 - 25,4 BT-R12-14GA49,122,2 - 28,6 BT-R12-16GA52,325,4 - 31,828,6 - 34,9

BT-R12-18GABT-R12-20GA

55,558,7

4,77,911,114,317,520,623,827,030,2

BTC-R12GA/GAH

> <> <k

(mm)

Clampload

kN

Ref.of the collar>

<

><

BTC-R12GA/GAH 19,56 mm

14,35 mm

><

d1 = Diameter - I = Length of the stem - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>>

Page 119: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

119

No breaking of the riveting stem: increased corrosion resistance, reduced wastage, low installation noiseA better support provided by the collar and the head of the rivetSemi-automatic tooling installation: more accurate and rapidity in the installationUnique helical lock groove: Holds the collar on the stem prior to installationZinc collar / stem uncoated (add suffix "GA" to the reference for the zinc stem)

BobTail® - Steel - Imperial dimensions

Stem : Steel | Head : Brazier

12,7 - 14,3

6,4 - 15,7

75,8 62,3 53,6

Ø(mm)

d1(mm)

l(mm)

l2(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

><

><

1/2(12,7 mm)

24,2 8,5

BTR-BR16-4GA48,312,7 - 22,1 BTR-BR16-8GA54,619,1 - 28,4 BTR-BR16-12GA61,025,4 - 34,8 BTR-BR16-16GA67,331,8 - 41,1 BTR-BR16-20GA73,738,1 - 47,5 BTR-BR16-24GA80,044,5 - 53,8 BTR-BR16-28GA86,450,8 - 60,257,2 - 66,563,5 - 72,969,9 - 79,276,2 - 85,682,6 - 91,988,9 - 98,395,3 - 104,6

BTR-BR16-32GABTR-BR16-36GABTR-BR16-40GABTR-BR16-44GABTR-BR16-48GABTR-BR16-52GABTR-BR16-56GABTR-BR16-60GA

92,799,1105,4111,8118,1124,5130,8137,2

3,8

9,5

BTC5-R16GA

> <> <k

(mm)

Clampload

kN

Ref.of the collar>

<

><

BTC5-R16GA 13,2 mm

19,0 mm

><

d1 = Diameter - I = Length of the stem - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>>

Page 120: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

120

Range of LockBolt®

No breaking of the riveting stem: increased corrosion resistance, reduced wastage, low installation noiseA better support provided by the collar and the head of the rivetSemi-automatic tooling installation: more accurate and rapidity in the installationUnique helical lock groove: Holds the collar on the stem prior to installationZinc collar / stem uncoated (add suffix "GA" to the reference for the zinc stem)

BobTail® - Steel - Imperial dimensions

Stem : Steel | Head : Brazier

15,9 - 17,5

6,4 - 15,7

120,5 100,1 85,4

Ø(mm)

d1(mm)

l(mm)

l2(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

><

><

5/8(15,9 mm)

30,4 11,0

BTR-BR20-4GA52,612,7 - 22,1 BTR-BR20-8GA58,919,1 - 28,4 BTR-BR20-12GA65,325,4 - 34,8 BTR-BR20-16GA71,631,8 - 41,1 BTR-BR20-20GA78,038,1 - 47,5 BTR-BR20-24GA84,344,5 - 53,8 BTR-BR20-28GA90,750,8 - 60,257,2 - 66,563,5 - 72,969,9 - 79,276,2 - 85,6

BTR-BR20-32GABTR-BR20-36GABTR-BR20-40GABTR-BR20-44GABTR-BR20-48GA

97,0103,4109,7116,1122,4

3,8

9,5

BTC5-R20GA

> <> <k

(mm)

Clampload

kN

Ref.of the collar>

<

><

BTC5-R20GA 16,4 mm

23,7 mm

><

d1 = Diameter - I = Length of the stem - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>>

Page 121: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

121

No breaking of the riveting stem: increased corrosion resistance, reduced wastage, low installation noiseA better support provided by the collar and the head of the rivetSemi-automatic tooling installation: more accurate and rapidity in the installationUnique helical lock groove: Holds the collar on the stem prior to installationZinc collar / stem uncoated (add suffix "GA" to the reference for the zinc stem)

BobTail® - Steel - Imperial dimensions

Stem : Steel | Head : Brazier

19,1 - 20,6

6,4 - 15,7

178,4 144,1 126,3

Ø(mm)

d1(mm)

l(mm)

l2(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

><

><

3/4(19,1 mm)

36,6 13,5

BTR-BR24-4GA61,812,7 - 22,1 BTR-BR24-8GA68,119,1 - 28,4 BTR-BR24-12GA74,525,4 - 34,8 BTR-BR24-16GA80,831,8 - 41,1 BTR-BR24-20GA87,238,1 - 47,5 BTR-BR24-24GA93,544,5 - 53,8 BTR-BR24-28GA99,950,8 - 60,257,2 - 66,563,5 - 72,969,9 - 79,276,2 - 85,6

BTR-BR24-32GABTR-BR24-36GABTR-BR24-40GABTR-BR24-44GABTR-BR24-48GA

82,6 - 91,9 BTR-BR24-52GA88,9 - 98,395,3 - 104,6101,6 - 111,0108,0 - 117,3114,3 - 123,7

BTR-BR24-56GABTR-BR24-60GABTR-BR24-64GABTR-BR24-68GABTR-BR24-72GA

106,2112,6118,9125,3131,6138,0144,3150,7157,0163,4169,7

4,1

9,5

BTC5-R24GA

> <> <k

(mm)

Clampload

kN

Ref.of the collar>

<

><

BTC5-R24GA 19,7 mm

28,3 mm

><

d1 = Diameter - I = Length of the stem - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>>

Page 122: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

122

Range of LockBolt®

No breaking of the riveting stem: increased corrosion resistance, reduced wastage, low installation noiseA better support provided by the collar and the head of the rivetSemi-automatic tooling installation: more accurate and rapidity in the installationUnique helical lock groove: Holds the collar on the stem prior to installationZinc collar / stem uncoated (add suffix "GA" to the reference for the zinc stem)

BobTail® - Steel - Imperial dimensions

Stem : Steel | Head : Brazier

22,2 - 23,8

6,4 - 15,7

246,7 193,1 174,6

Ø(mm)

d1(mm)

l(mm)

l2(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

><

><

7/8(22,2 mm)

42,3 14,9

BTR-BR28-4GA68,712,7 - 22,1 BTR-BR28-8GA75,119,1 - 28,4 BTR-BR28-12GA81,425,4 - 34,8 BTR-BR28-16GA87,831,8 - 41,1 BTR-BR28-20GA94,138,1 - 47,5 BTR-BR28-24GA100,544,5 - 53,8 BTR-BR28-28GA106,850,8 - 60,257,2 - 66,563,5 - 72,969,9 - 79,276,2 - 85,6

BTR-BR28-32GABTR-BR28-36GABTR-BR28-40GABTR-BR28-44GABTR-BR28-48GA

82,6 - 91,9 BTR-BR28-52GA88,9 - 98,395,3 - 104,6101,6 - 111,0108,0 - 117,3114,3 - 123,7

BTR-BR28-56GABTR-BR28-60GABTR-BR28-64GABTR-BR28-68GABTR-BR28-72GA

113,2119,5125,9132,2138,6144,9151,3157,6164,0170,3176,7

6,4

12,7

BTC5-R28GA

> <> <k

(mm)

Clampload

kN

Ref.of the collar>

<

><

BTC5-R28GA 22,9 mm

33,0 mm

><

d1 = Diameter - I = Length of the stem - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>>

Page 123: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

123

No breaking of the riveting stem: increased corrosion resistance, reduced wastage, low installation noiseA better support provided by the collar and the head of the rivetSemi-automatic tooling installation: more accurate and rapidity in the installationUnique helical lock groove: Holds the collar on the stem prior to installationZinc collar / stem uncoated (add suffix "GA" to the reference for the zinc stem)

BobTail® - Steel - Imperial dimensions

Stem : Steel | Head : Brazier

25,4 - 28,6

6,4 - 15,7

323,4 251,3 229,1

Ø(mm)

d1(mm)

l(mm)

l2(mm)

d2(mm)

min - max(mm)

kNmin

kNmin

>

>

><

><

1(25,4 mm)

50,8 16,5

BTR-BR32-4GA76,212,7 - 22,1 BTR-BR32-8GA82,619,1 - 28,4 BTR-BR32-12GA88,925,4 - 34,8 BTR-BR32-16GA95,431,8 - 41,1 BTR-BR32-20GA101,638,1 - 47,5 BTR-BR32-24GA108,044,5 - 53,8 BTR-BR32-28GA114,350,8 - 60,257,2 - 66,563,5 - 72,969,9 - 79,276,2 - 85,6

BTR-BR32-32GABTR-BR32-36GABTR-BR32-40GABTR-BR32-44GABTR-BR32-48GA

82,6 - 91,9 BTR-BR32-52GA88,9 - 98,395,3 - 104,6101,6 - 111,0108,0 - 117,3114,3 - 123,7

BTR-BR32-56GABTR-BR32-60GABTR-BR32-64GABTR-BR32-68GABTR-BR32-72GA

120,7127,0133,4139,7146,1152,4158,8165,1171,5177,8184,2

6,4

12,7

BTC5-R32GA

> <> <k

(mm)

Clampload

kN

Ref.of the collar>

<

><

BTC5-R32GA 26,2 mm

37,8 mm

><

d1 = Diameter - I = Length of the stem - = Min. and Max. grip range - Ø = Hole diameter - k = Head thickness

d2 = Head diameter - = Minimum tensile strength - = Minimum shear strength

>>

Page 124: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

124

Installation tools®

There is a wide range of riveting machines available for the installation of HUCK® structural blind rivets andLockBolts. The choice of the riveter depends on the type and the diameter of the rivet as well as the conditionsof accessibility of the application. In most cases, the HUCK® riveting machines can be used for the installation ofLockBolt and structural rivets, it is only necessary to change the nose assembly

The HUCK® structural rivets and LockBolt respect all specifications indicated provided that that they have beeninstalled with the appropriate riveting machine

The HUCK® riveting machine enables a simple and reliable installation, regardless of the operator's dexterity.The speed of the installation cycle enable to reduce assembly times by about 75%

The most common HUCK® installation tools are presented below, although this is only a small part of the overall range.Please do not hesitate to contact us for any special requests.

Page 125: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

125

Equipment and tools required for the installation of HUCK® rivets

Weight (Kg)

Tensile force (kN)

Setting stroke (mm)

Ø blind rivet (mm)

Ø LockBolt (mm)

There are 3 options of electrical Powerig™ for a use with hydraulic installation tools.BOLLHOFF recommends the use of the hydraulic unit HK32-002 (see page 131).

Add for each tool the laying nose associated to the fastener type to be installed (see the table p132-133)

Add for each tool the laying nose associated to the fastener type to be installed (see the table p132-133)

202V 2025LB 254

2,31

17,30

19,00

4,8 - 6,4

2,61

23,53

17,15

4,8 - 9,5

4,8 - 6,4

3,90

38,34

14,30

4,8 - 9,5

7,9 - 9,5

HuckForce Powerig™ Range

Hydropneumatic tools

Weight (Kg)

Tensile force (kN)

Setting stroke (mm)

Ø blind rivet (mm)

ØØ LockBolt (mm)

2480L 2581-2 2583 2620PT SF20 3585

1,0 2,49 2,09 4,48 5,0 8,62

24,0 47,5 48,3 78,93 92,0 203,0

22,2 23,8 38,1 36,5 50,8 46

4,8 - 9,5 7,9 4,8 - 9,5 9,5 - 12,7 – 15,9

4,8 - 6,4 4,8 - 9,5 7,9 - 9,5 12,7 12,7 - M16 12,7 - 19,1

Hydraulic tools

Page 126: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

226 202 01 001

226 201 01 001

126

Hydropneumatic tools®

202V

Benefits:

� Lightweight and fast allowing to reduce theoperator fatigue

� Ergonomically designed handle

� Collection bottle available to collect pintails.

2025LB

Benefits:

� Ergonomically designed handle

� Robust design

� Fitted pintail bottle

Characteristics

Stroke

Capacity

Weight

Consommation d'air

Hydraulic fluid

17 mm

23,53 kN to 6,2 bar

2,61 kg

240 l/min based on30 cycles per min.

DEXRON II AutomaticTransmission Fluid orequivalent to ATFSpecification

L x A dimensions 245 x 318 mm

12,79,57,96,44,8

Diameter (mm)Installation tools

Magna-Lok®226 215 00 043 (99-3303L)

� 226 215 00 025 (99-3305L)

226 215 00 043 (99-3303L)

226 215 00 025 (99-3305L)

226 215 00 043 (99-3303L)

226 215 00 025 (99-3305L)

226 215 00 043 (99-3303L)

226 215 00 025 (99-3305L)

Auto-Bulb®�

Magna-Bulb®�

HuckLok®�

Compatiblerivet types

12,79,57,96,44,8

Diameter (mm)Installation tools

Magna-Lok®226 215 00 043 (99-3303L)

� 226 215 00 025 (99-3305L)

226 215 00 043 (99-3303L)

226 215 00 025 (99-3305L)

226 215 00 043 (99-3303L)

226 215 00 025 (99-3305L)

226 215 00 043 (99-3303L)

226 215 00 025 (99-3305L)

Auto-Bulb®�

Magna-Bulb®�

HuckLok®�

C6L®226 215 00 142 (99-3003L)

� 226 215 00 143 (99-3006L)

Magna-Grip®226 215 00 161 (99-1456L)

� 226 215 00 091 (99-1477UKL)

�Hucktainer® 226 215 00 164 (99-3464L)

Compatiblerivet types

Characteristics

Stroke

Capacity

Weight

Air consumption

Hydraulic fluid

18,9 mm

17,3 kN to 6,21 bar

2,31 kg

Hydraulic pressure (max) 5,5 - 6,9 bar

244 l/min based on30 cycles per min

DEXRON II AutomaticTransmission Fluid orequivalent to ATFSpecification

L x A dimensions 258 x 304 mm

Page 127: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

226 208 01 001

127

254

Characteristics

Benefits:

� Compact and ergonomic

� Very good weight to power ratio

� Easy maintenance

� Pull piston is reinforced

Stroke

Capacity

Weight

Hydraulic pressure (max)

Air consumption

Hydraulic fluid

14,3 mm

38,34 kN to 6,2 bar

3,9 kg

6,2 - 6,9 bar

382 l/min based on30 cycles per min

L x A dimensions 204 x 379 mm

12,79,57,96,44,8

Diameter (mm)Installation tools

�Magna-Bulb® 226 215 00 153 (99-3307)

�Magna-Lok® 226 215 00 115 (99-3329)

Bom®226 215 00 155 (99-1053)

� 226 215 00 044 (99-830-1)

C6L®226 215 00 159 (99-99-245)

� 226 215 00 160 (99-100-245)

�C120L®

Magna-Grip®

226 215 00 159 (99-99-245)

� 226 215 00 162 (99-1439)

Compatiblerivet types

DEXRON II AutomaticTransmission Fluid orequivalent to ATFSpecification

Page 128: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

226 215 00 095

128

Hydraulic tools®

Stroke

Capacity

Weight

Return pressure (max)

22,2 mm

25,4 kN to 579 bar

1,0 kg

Hydraulic pressure (max) 579 bar

221 bar

L x A dimensions 208 x 166 mm

2480L

Characteristics

Benefits:

� Lightweight

� Increased reliability

� Simple design for minimal maintenance

Hydraulic fluid

DEXRON II AutomaticTransmission Fluid orequivalent to ATFSpecification

12,79,57,96,44,8

Diameter (mm)Installation tools

Magna-Lok®�

Auto-Bulb®�

Magna-Bulb®�

HuckLok®�

C6L®�

Magna-Grip®�

�Hucktainer®

�Bobtail® 226 215 00 149 (99-7932L)

Compatiblerivet types

Stroke

Capacity

Weight

Return pressure (max)

23,8 mm

47,5 kN to 510 bar

2,49 kg

Hydraulic pressure (max) 510 bar

220 bar

L x A dimensions 180 x 214 mm

2581-2

Characteristics

Benefits:

� Lightweight and compact tool

� Simple design

� Suitable for use in areas where access is limited

Hydraulic fluid

Must match DEXTRON® III,DEXTRON® VI, MERCON,Allison C-4 specifications

or equivalent ATFspecifications

12,79,57,96,44,8

Diameter (mm)Installation tools

�Magna-Bulb® 226 215 00 153 (99-3307)

� 226 215 00 155 (99-1053)

BOM®226 215 00 044 (99-830-1)

� 226 215 00 080 (99-769)

� 226 215 00 022 (99-1272)

� 226 215 00 159 (99-99-245)

� 226 215 00 160 (99-100-245)

� 226 215 00 159 (99-99-245)

C6L®

226 215 00 160 (99-100-245)

� 226 215 00 162 (99-1439)

C120L®

226 215 00 163 (99-1440)Magna-Grip®

Compatiblerivet types

226 203 01 001

226 215 00 043 (99-3303L)

226 215 00 025 (99-3305L)

226 215 00 043 (99-3303L)

226 215 00 025 (99-3305L)

226 215 00 043 (99-3303L)

226 215 00 025 (99-3305L)

226 215 00 043 (99-3303L)

226 215 00 025 (99-3305L)

226 215 00 142 (99-3003L)

226 215 00 143 (99-3006L)

226 215 00 161 (99-1456L)

226 215 00 091 (99-1477UKL)

226 215 00 164 (99-3464L)

Page 129: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

226 215 00 079

129

2583

Benefits:

� Lightweight and compact

� Adapted to install fasteners in limited clearance

� Low maintenance

12,79,57,96,44,8

Diameter (mm)Installation tools

�Magna-Bulb® 226 215 00 153 (99-3307)

� 226 215 00 115 (99-3329)Magna-Lok®

� 226 215 00 155 (99-1053)

�BOM® 226 215 00 044 (99-830-1)

� 226 215 00 080 (99-769)

�FloorTight® 226 215 00 158 (99-3452)

� 226 215 00 159 (99-99-245)

�C6L®

226 215 00 160 (99-100-245)

� 226 215 00 159 (99-99-245)

�C120L®

226 215 00 160 (99-100-245)

� 226 215 00 162 (99-1439)

�Magna-Grip®

226 215 00 163 (99-1440)

Bobtail®226 215 00 151 (99-7923)

� 226 215 00 152 (99-7924)

Compatiblerivet types

Stroke

Capacity

Weight

Return pressure

36,5 mm

78,93 kN to 448 bar

4,5 kg

Pression hydraulique 510 bar

221 bar

L x A dimensions 167 x 179 mm

2620-PT

Characteristics

Benefits:

� Designed for the installation of large rivets

� Robust design

� Easy maintenance

12,79,57,96,44,8

Diameter (mm)Installation tools

�Magna-Lok® 226 215 00 154 (99-3331)

� 226 215 00 156 (99-3122)

�BOM®

226 215 00 157 (99-5101)

� 226 215 00 111 (99-5002)C50L®

Compatiblerivet types

Stroke

Capacity

Weight

Return pressure (max)

31,8 mm

48,3 kN to 580 bar

2,09 kg

Hydraulic pressure (max) 580 bar

22 bar

L x A dimensions 186 x 239 mm

Characteristics

Hydraulic fluid

DEXRON II AutomaticTransmission Fluid orequivalent to ATFSpecification

226 215 00 150

Page 130: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

130

Hydraulic tools®

Stroke

Capacity

Weight

Return pressure (max)

50,8 mm

92 kN to 483 bar

5,0 kg

Hydraulic pressure (max) 483 bar

345 bar

L x A dimensions 141 x 216 mm

SF20

Characteristics

Benefits:

� Very good weight to power ratio

� Tool is for the installation of BobTail® LockBolts

� Offers a quicker and easier installation process

Hydraulic fluid

Must match DEXTRON® III,DEXTRON® VI, MERCON,Allison C-4 specifications

or equivalent ATFspecifications

M16M14M1215,912,7

Diameter (mm)Installation tools

Bobtail®

226 215 00 049 (99-7882)

� 226 215 00 167 (99-7881)

� 226 215 00 146 (99-7880)

� 226 215 00 147 (99-7884)

� 226 215 00 148 (99-7881)

Compatiblerivet types

Stroke

Capacity

Weight

Return pressure (max)

46 mm

203 kN to 510 bar

8,62 kg

Hydraulic pressure (max) 510 bar

151 bar

L x A dimensions 199 x 263 mm

3585

Characteristics

Benefits:

� Important setting force

� Ergonomic design

� Ejection of broken stem is facilitated

Hydraulic fluid

Must match DEXTRON® III,DEXTRON® VI, MERCON,Allison C-4 specifications

or equivalent ATFspecifications

12,7

Diameter (mm)Installation tools

BOM® 226 215 00 081 (99-5102)

226 215 00 110 (99-5008)C50L®

226 215 00 046 (99-5010)

� 226 215 00 165 (99-7835)

226 215 00 166 (99-7831)

15,9

19,1

� 226 215 00 168 (99-7836)

Bobtail®

Compatiblerivet types

226 215 00 048

226 215 00 109

Page 131: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

226 215 00 047

131

Powerig® hydraulic group

Engine

Power supply

Weight

Debit

2,2 kW

3x400 VCA (nominal)50 Hz

97 kg(Hydraulic oil included)

Machine output 1

3,2 l/min (nominal)

L x A x P dimensions 720 x 500 x 800 mm

HK32-002 Powerig® - Hydraulic power system

Hydraulic hoses - Hydraulic tool connection / Powerig®

Characteristic

Benefits:

� For intensive use

� Ideal for large production volumes

� Manœuvre of the rig is easy, thanks to built-inwheels

� Sureset / Control process option is available

Hydraulic pressure (max) 600 bar

Reference

5 meters 226 215 00 119 (HS-05-MCE)

10 meters 226 215 00 033 (HS-10-MCE)

15 meters 226 215 00 050 (HS-15-MCE)

20 meters 226 215 00 169 (HS-20-MCE)

Length

Page 132: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

132

Summary table "Tool / Laying nose / Fastener"®

HuckLok®

Magna-Lok®

Magna-Bulb®

Auto-Bulb®

2480L

HYDRAULIC TOOLS

2581-2 2583 2620PT

99-3303L

99-3305L

Magna-Bulb®

Magna-Lok®

BOM®

FloorTight®

C6L®

C120L®

Magna-Grip®

HuckTainer®

C50L®

BobTail®

99-3003L

99-3006L

99-1456L

99-1477UKL

99-3464L

99-7932L

99-3307

99-1053

99-830-1

99-769

99-1272

99-99-245

99-100-245

99-99-245

99-100-245

99-1439

99-1440

99-3307

99-3318 ou 99-3329

99-1053

99-830-1

99-769

99-3452

99-99-245

99-100-245

99-99-245

99-100-245

99-1439

99-1440

99-7923

99-7924

99-3331

99-3122

99-5101

99-5002

4,8

6,4

7,9

9,5

12,7

4,8

6,4

7,9

9,5

12,7

15,9

7,9

4,8

6,4

7,9

9,5

7,9

9,5

4,8

6,4

7,9

9,5

9,5

12,7

15,9

19,1

6,4

7,9

9,5

12,7

15,9

19,1

M12

M14

M16

For more information please visit the following link:https://www.afsrhuck.net/us/en/More_Information/toolingresource-en.html

Page 133: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

133

3585 SF20

99-5102

99-5008

99-5010

99-7835

99-7831

99-7836

99-7882

99-7881

99-7880

99-7884

99-7881

202V

HYDROPNEUMATIC TOOLS

2025LB 254

99-3303L

99-3305L

99-3303L

99-3305L

99-3003L

99-3006L

99-1456L

99-1477UKL

99-3464L

99-3307

99-3318 ou 99-3329

99-1053

99-830-1

99-99-245

99-100-245

99-99-245

99-1439

Page 134: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

STRUCTURAL RIVET

134

Applications of HUCK® fastening systems®

Benefits:

� A simple and fast installation enable to reducedthe assembly times of 75%

� Solid fasteners resistant to extreme vibrations,which use fewer parts and allow weight andcost savings

� High quality assembly and sustainability, requiringno maintenance, resulting in lower costs

� Guaranteed return on investment

1. Magna-Bulb®

• Self locking structural rivet with60° lock• High tensile and shear strength• High resistance to vibration andloosening• The good distribution of thejoining strengths allows theinstallation on materials ofsmall thicknesses• Breaking of the riveting stemis flush• TIR Certificate

Installation of the windows,fixing of the roof and lateralestructure, arc of the wheel

2. HuckLokTM

• Self locking structural rivet• Unique system of doubleinternal pin locking formaximum assembly integrityand high resistance to fatigue• High resistance to tensionloss in the assembly due tovibrations•Wide clamping range, reducesthe number of fasteners• Breaking of the riveting stemis flush

Installation of the windows, fixingof the roof and laterale structure,arc of the wheel

3. Magna-Lok®

• Structural rivet with internal pinlocking mechanism• Very high shear and hightensile strength• High resistance to tensionloss in the assembly due tovibrations•Wide clamping range, reducesthe number of fasteners• Breaking of the riveting stemis flush• TIR Certificate

Seat fasteners, ceiling

4. BOM®

• Structural blind rivet in steel,high resistance• Realise an efficient assembly

Fixing of pillars, fixing of angles,fixing of bumpers

� � �

��

��

Page 135: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

135

5. Magna-TiteTM

• Structural rivet with highresistance and watertightwhich is ensured by apolymer seal• Wide clamping range,allowing to reduce the numberof fasteners• Extra large blind side footprint:Ideal for joining of plastic andcomposites materials, lowerstrength or thin sheet jointmaterials• Breaking of the riveting stemis flush• TIR Certificate

No leaks - Roof fixing

6. Magna-Grip®

• LockBolt, consistent andwith a wide clamping range• Good vibrations resistance• Large clamping range,allowing to reduce thenumber of fasteners• Breaking of the riveting stemis flush• TIR Certificate

Fixing of pillars, roof, wheel arc,assembly of rear frame

7. C6L®

• LockBolt with high tensilestrength and to vibrations• Has 6 grooves in the joiningarea allowing a greaterclamping range

Fixing of roof and pillars

8. BobTail®

• Lockbolt with collar or stemin steel of 10,9 grade•Without breaking of theriveting stem : increase theresistance to corrosion,reduction of waste, noise levelis low during the installation• Offers all the advantages ofhigh strength rivets combinedwith better support providedby the collar and the head ofthe rivet• Installation with semi-automatic riveter: moreprecision and faster• Helical lock groove, holdsthe collar on the stem priorto installation

Frame, fixing of the side walls

LOCKBOLT

� �

��

��

Page 136: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

136

Applications of HUCK® fastening systems®

Benefits:

� A simple and fast installation enable to reducedthe assembly times of 75%

� Solid fasteners and resistant to vibrations,allowing to use fewer parts and allows weightand cost savings

� High quality assembly and sustainability, requiringno maintenance, resulting in lower costs

� Guaranteed return on investment

1. Magna-Bulb®

• Self locking structural rivetwith 60° lock• High tensile and shearstrength• High resistance to vibrationand loosening• The good distribution ofthe joining strengths allowsthe installation on materialsof small thicknesses• Breaking of the rivetingstem is flush• TIR Certificate

Fixing of angles, aluminiumpanels and floors, archedroof structure

2. HuckLokTM

• Self locking structural rivet• Unique system of doubleinternal pin locking formaximum assemblyintegrity and highresistance to fatigue• High resistance to tensionloss in the assembly dueto vibrations•Wide clamping range,reduces the number offasteners• Breaking of the rivetingstem is flush

Applications on trailer roofs,fixing of angles, curtain railsand the external structure ofrefrigerated trailers

3. BOM®

• Structural blind rivetin steel, high resistance• Realise an efficientassembly

For very demandingapplications. In trailerapplications, fixing of angles,door locking bracket,mounting bracket

4. FloorTight®

• Superior resistance rivet• Blind installation• High tensile and shearstrength• High setting force• A countersunk head allowsthe rivet to remaincompletely flush once itis installed

Trailer floor

5. Magna-TiteTM

• Structural rivet with highresistance and watertightwhich is ensured by apolymer seal• Wide clamping range,reduces the number offasteners• Extra large blind sidefootprint: Ideal for joiningof plastic and compositesmaterials, lower strengthor thin sheet joint materials• Breaking of the rivetingstem is flush• TIR Certificate

Trailers roof and lockingsystems

STRUCTURAL RIVET

� �

Page 137: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

137

6. Magna-Grip®

• LockBolt, consistent andwith a wide clamping range• Good vibrations resistance•Wide clamping range,reduces the number offasteners• Breaking of the rivetingstem is flush• TIR Certificate

Fastening of belts andfastening of the chassisstructure in truck cabs

7. C50L®

• LockBolts for assembliessubject to very demandingconditions• 8.8 grade• High resistance to vibration• Easy visual inspection ofthe installation quality

Trailer chassis

8. C6L®

• LockBolt with high tensilestrength and to vibrations• Has 6 grooves in the joiningarea allowing to get agreater clamping range

Fixing of truck bumpers,radiator mounting

9. Hucktainer®Plus

• Designed specifically forjoining composite boardin trailer applications.• Will not crush or damagethe GRP composite plates• Wide clamping range• The low profile providesa high quality finish

• The tightness under thehead of the stem preventmoisture• TIR Certificate

Trailers chassis

10. BobTail®

• Lockbolt with collar or stemin steel of 10.9 grade• No breaking of the rivetingstem : increased corrosionresistance, reducedwastage, low installationnoise• Offers all the advantagesof high strength rivetscombined with bettersupport provided by thecollar and the head ofthe rivet• Installation with semi-automatic riveter: fasterand more precise• Helical lock groove, holdsthe collar on the stem priorto installation

Trailers chassis, fixing of theside walls

LOCKBOLT

� � �

��

10

10

10

Page 138: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

138

Applications of HUCK® fastening systems®

Benefits:

� A simple and fast installation enabled to reduceassembly times by 75%

� Solid fasteners and vibration resistant, allowingfewer parts to be used and allows weight andcost savings

� High quality assembly and sustainability, requiringno maintenance, resulting in lower costs

� Guaranteed return on investment

STRUCTURAL RIVET

1. Magna-Bulb®

• Self locking structural rivetwith 60° lock• High tensile and shearstrength• High resistance to vibrationand loosening• The good distribution ofthe joining strengths allowsthe installation on materialsof small thicknesses• Breaking of the rivetingstem is flush• TIR Certificate

2. HuckLokTM

• Self locking structural rivet• Unique system of doubleinternal pin locking formaximum assemblyintegrity and highresistance to fatigue• High resistance to tensionloss in the assemblycaused by vibrations•Wide clamping range,reduces the numberof fasteners• Breaking of the rivetingstem is flush

3. Magna-Lok®

• Structural rivet with internalpin locking mechanism• High tensile and shearstrength• High resistance to vibrationand loosening•Wide clamping range,reduces the number offasteners• Breaking of the rivetingstem is flush• TIR Certificate

4. BOM®

• Structural blind rivet insteel, high resistance• Realise an efficientassembly

5. Auto-Bulb®

• Purpose design blind sideshape for easy holelocation• Large diameter head andlarge bulge whichdistributes the load overa larger area

Panels: HUCK® fastening systemsallow quick, easy and clean installationof pre-painted panels. A robustand tamperproof assembly isguaranteed

Lifting clamp: HUCK® fasteningsystems are resistant to vibrations,extend the life of lifting clamp, andoffer assemblies that require nomaintenance. Easy to install.

Page 139: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

Ventilator: HUCK® fastening systemsoffer assemblies which require nomaintenance and offer assembliesof high resistance to fatigue andvibrations. It's easy to install.

A group of building: the clampingforce of the HUCK® fastening systemsis high, which improves the integrity of

the assembly without the need totighten and retighten the

torque. Easy installation forfast modular construction.

Radiator: assemblies realized withHUCK® fastening systems are resistantto vibrations and extremetemperatures.

They require no maintenance.They are so resistant that you canuse a smaller amount of rivets.

Easy to install.

139

LOCKBOLT

6. Magna-Grip®

• LockBolt, consistent andwith a wide clamping range• Good vibration resistance•Wide clamping range,reduces the number offasteners• Breaking of the rivetingstem is flush

7. C50L®

• LockBolts for assembliessubject to very demandingconditions• 8.8 grade• High resistance to vibration• Easy visual inspection ofthe installation quality

8. C6L/120L®

• LockBolt with high tensilestrength vibration resistant• Has 6 grooves in thejoining area allowing to geta greater clamping range

9. Huck-Fit®

• LockBolts for assembliessubject to very demandingconditions with uniquehelical lock groove toincrease the life of thejoining• Easy installation thanksto the support of thecollar on the stem priorto installation• Joints have a highresistance to vibration• Can be unscrewed asa standard bolt with amonkey wrench• 10.9 grade

10. Huck-Spin®

• Lockbolt without breakingof the riveting stem withunique helical lock grooveto increase the life ofthe joint• The "control process"ensures precise installation• High resistance to tensionloss in the assembly dueto vibrations• Can be unscrewed asa standard bolt withan monkey wrench• 10.9 grade

Page 140: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

140

Numerical index®

2LC120-R6G

2LC120-R8G

2LC120-R10G

2LC120-R12G

2LC-2CU6

2LC-2CU8

2LC-2CU10

2LC-2CU12

2LC-F6

2LC-F8

2LC-F10

2LC-F12

2LC-R6G

2LC-R8G

2LC-R10G

2LC-R12G

3LC120-2R6G

3LC120-2R8G

3LC120-2R10G

3LC120-2R12G

3LC-2CU6

3LC-2CU8

3LC-2CU10

3LC-2CU12

3LC-2CU16

3LC-2CU20

3LC-2R6G

3LC-2R8G

3LC-2R10G

3LC-2R12G

3LC-2R16G

3LC-2R20G

3LC-2R24G

3LC-2R28G

3LC-2R32G

3LC-F6

3LC-F8

3LC-F10

3LC-F12

3LC-I6

3LC-I8

3LC-I10

3LC-I12

8LC-2CU20

8LC-2R28G

ABP-4U8-M2

ABP-4U8-M3

ABP-4U8-M4

ABP-4U8-M5

ABP-4U8-M6

82-86-90

83-87-91

84-88-92

85-89-93

42-54-70

43-55-71

44-56-72

45-57-73

58-74

59-75

60-76

61-77

38-50-66

39-51-67

40-52-68

41-53-69

82-86-90

83-87-91

84-88-92

85-89-93

42-54-70

43-55-71

44-56-72

45-57-73

100

101

38-50-66

39-51-67

40-52-68

41-53-69

94-102

95-103

96-104

97

98

58-74

59-75

60-76

61-77

46-62-78

47-63-79

48-64-80

49-65-81

101

97

17

17

17

17

17

ABP-4U8-M7

ABP-4U8-M8

ABP-4U8-M9

ABP-4U8-M10

ABP-4U8-M12

ABP-4U8-M19

ABP-R6-M2

ABP-R6-M3

ABP-R6-M4

ABP-R6-M5

ABP-R8-M2

ABP-R8-M3

ABP-R8-M4

ABP-R8-M5

ABP-R8-M6

ABP-R8-M7

ABP-R8-M8

ABP-R8-M9

ABP-R8-M10

ABP-R8-M11

ABP-R8-M19

BOM-R6-2

BOM-R6-3

BOM-R6-4

BOM-R6-5

BOM-R6-6

BOM-R6-7

BOM-R6-8

BOM-R6-9

BOM-R6-10

BOM-R6-11

BOM-R6-12

BOM-R8-2

BOM-R8-3

BOM-R8-4

BOM-R8-5

BOM-R8-6

BOM-R8-7

BOM-R8-8

BOM-R8-9

BOM-R8-10

BOM-R8-11

BOM-R8-12

BOM-R8-13

BOM-R8-14

BOM-R10-4

BOM-R10-6

BOM-R10-8

BOM-R10-10

BOM-R10-12

17

17

17

17

17

17

17

17

17

17

17

17

17

17

17

17

17

17

17

17

17

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

24

BOM-R10-14

BOM-R10-16

BOM-R12-4

BOM-R12-6

BOM-R12-8

BOM-R12-10

BOM-R12-12

BOM-R12-14

BOM-R12-16

BOM-R12-18

BOM-R12-20

BOM-R16-4

BOM-R16-6

BOM-R16-8

BOM-R16-10

BOM-R16-12

BOM-R16-14

BOM-R16-16

BOM-R16-18

BOM-R16-20

BOM-R16-22

BOM-R16-24

BOM-R20-4GA

BOM-R20-8GA

BOM-R20-12GA

BOM-R20-16GA

BOM-R20-20GA

BOM-R24-4GA

BOM-R24-8GA

BOM-R24-12GA

BOM-R24-16GA

BTC5-R16GA

BTC5-R20GA

BTC5-R24GA

BTC5-R28GA

BTC5-R32GA

BTC-R8GA/GAH

BTC-R10GA/GAH

BTC-R12GA/GAH

BT-R8-1GA

BT-R8-2GA

BT-R8-3GA

BT-R8-4GA

BT-R8-5GA

BT-R8-6GA

BT-R8-8GA

BT-R8-10GA

BT-R8-12GA

BT-R8-14GA

BT-R8-16GA

24

24

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

25

119

120

121

122

123

116

117

118

116

116

116

116

116

116

116

116

116

116

116

BT-R8-18GA

BT-R8-20GA

BT-R10-4GA

BT-R10-6GA

BT-R10-8GA

BT-R10-10GA

BT-R10-12GA

BT-R10-14GA

BT-R10-16GA

BT-R10-18GA

BT-R10-20GA

BT-R12-4GA

BT-R12-6GA

BT-R12-8GA

BT-R12-10GA

BT-R12-12GA

BT-R12-14GA

BT-R12-16GA

BT-R12-18GA

BT-R12-20GA

BTR-BR16-4GA

BTR-BR16-8GA

BTR-BR16-12GA

BTR-BR16-16GA

BTR-BR16-20GA

BTR-BR16-24GA

BTR-BR16-28GA

BTR-BR16-32GA

BTR-BR16-36GA

BTR-BR16-40GA

BTR-BR16-44GA

BTR-BR16-48GA

BTR-BR16-52GA

BTR-BR16-56GA

BTR-BR16-60GA

BTR-BR20-4GA

BTR-BR20-8GA

BTR-BR20-12GA

BTR-BR20-16GA

BTR-BR20-20GA

BTR-BR20-24GA

BTR-BR20-28GA

BTR-BR20-32GA

BTR-BR20-36GA

BTR-BR20-40GA

BTR-BR20-44GA

BTR-BR20-48GA

BTR-BR24-4GA

BTR-BR24-8GA

BTR-BR24-12GA

116

116

117

117

117

117

117

117

117

117

117

118

118

118

118

118

118

118

118

118

119

119

119

119

119

119

119

119

119

119

119

119

119

119

119

120

120

120

120

120

120

120

120

120

120

120

120

121

121

121

BTR-BR24-16GA

BTR-BR24-20GA

BTR-BR24-24GA

BTR-BR24-28GA

BTR-BR24-32GA

BTR-BR24-36GA

BTR-BR24-40GA

BTR-BR24-44GA

BTR-BR24-48GA

BTR-BR24-52GA

BTR-BR24-56GA

BTR-BR24-60GA

BTR-BR24-64GA

BTR-BR24-68GA

BTR-BR24-72GA

BTR-BR28-4GA

BTR-BR28-8GA

BTR-BR28-12GA

BTR-BR28-16GA

BTR-BR28-20GA

BTR-BR28-24GA

BTR-BR28-28GA

BTR-BR28-32GA

BTR-BR28-36GA

BTR-BR28-40GA

BTR-BR28-44GA

BTR-BR28-48GA

BTR-BR28-52GA

BTR-BR28-56GA

BTR-BR28-60GA

BTR-BR28-64GA

BTR-BR28-68GA

BTR-BR28-72GA

BTR-BR32-4GA

BTR-BR32-8GA

BTR-BR32-12GA

BTR-BR32-16GA

BTR-BR32-20GA

BTR-BR32-24GA

BTR-BR32-28GA

BTR-BR32-32GA

BTR-BR32-36GA

BTR-BR32-40GA

BTR-BR32-44GA

BTR-BR32-48GA

BTR-BR32-52GA

BTR-BR32-56GA

BTR-BR32-60GA

BTR-BR32-64GA

BTR-BR32-68GA

121

121

121

121

121

121

121

121

121

121

121

121

121

121

121

122

122

122

122

122

122

122

122

122

122

122

122

122

122

122

122

122

122

123

123

123

123

123

123

123

123

123

123

123

123

123

123

123

123

123

Page 141: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

141

BTR-BR32-72GA

C120L90-R6-3G

C120L90-R6-4G

C120L90-R6-5G

C120L90-R6-6G

C120L90-R6-7G

C120L90-R6-8G

C120L90-R6-9G

C120L90-R6-10G

C120L90-R6-11G

C120L90-R6-12G

C120L90-R6-13G

C120L90-R6-14G

C120L90-R6-15G

C120L90-R6-16G

C120L90-R6-17G

C120L90-R6-18G

C120L90-R6-19G

C120L90-R6-20G

C120L90-R6-21G

C120L90-R6-22G

C120L90-R6-23G

C120L90-R6-24G

C120L90-R6-25G

C120L90-R6-26G

C120L90-R6-27G

C120L90-R6-28G

C120L90-R6-29G

C120L90-R6-30G

C120L90-R6-31G

C120L90-R6-32G

C120L90-R8-3G

C120L90-R8-4G

C120L90-R8-5G

C120L90-R8-6G

C120L90-R8-7G

C120L90-R8-8G

C120L90-R8-9G

C120L90-R8-10G

C120L90-R8-11G

C120L90-R8-12G

C120L90-R8-13G

C120L90-R8-14G

C120L90-R8-15G

C120L90-R8-16G

C120L90-R8-17G

C120L90-R8-18G

C120L90-R8-19G

C120L90-R8-20G

C120L90-R8-21G

123

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

90

91

91

91

91

91

91

91

91

91

91

91

91

91

91

91

91

91

91

91

C120L90-R8-22G

C120L90-R8-23G

C120L90-R8-24G

C120L90-R8-25G

C120L90-R8-26G

C120L90-R8-27G

C120L90-R8-28G

C120L90-R8-29G

C120L90-R8-30G

C120L90-R8-31G

C120L90-R8-32G

C120L90-R10-4G

C120L90-R10-6G

C120L90-R10-8G

C120L90-R10-10G

C120L90-R10-12G

C120L90-R10-14G

C120L90-R10-16G

C120L90-R10-18G

C120L90-R10-20G

C120L90-R10-22G

C120L90-R10-24G

C120L90-R10-26G

C120L90-R10-28G

C120L90-R10-30G

C120L90-R10-32G

C120L90-R12-6G

C120L90-R12-8G

C120L90-R12-10G

C120L90-R12-12G

C120L90-R12-14G

C120L90-R12-16G

C120L90-R12-18G

C120L90-R12-20G

C120L90-R12-22G

C120L90-R12-24G

C120L90-R12-26G

C120L90-R12-28G

C120L90-R12-30G

C120L90-R12-32G

C120LB-R6-2G

C120LB-R6-3G

C120LB-R6-4G

C120LB-R6-5G

C120LB-R6-6G

C120LB-R6-7G

C120LB-R6-8G

C120LB-R6-9G

C120LB-R6-10G

C120LB-R6-11G

91

91

91

91

91

91

91

91

91

91

91

92

92

92

92

92

92

92

92

92

92

92

92

92

92

92

93

93

93

93

93

93

93

93

93

93

93

93

93

93

82

82

82

82

82

82

82

82

82

82

C120LB-R6-12G

C120LB-R6-13G

C120LB-R6-14G

C120LB-R6-15G

C120LB-R6-16G

C120LB-R6-17G

C120LB-R6-18G

C120LB-R6-19G

C120LB-R6-20G

C120LB-R6-21G

C120LB-R6-22G

C120LB-R6-23G

C120LB-R6-24G

C120LB-R6-25G

C120LB-R6-26G

C120LB-R6-27G

C120LB-R6-28G

C120LB-R6-29G

C120LB-R6-30G

C120LB-R6-31G

C120LB-R6-32G

C120LB-R8-2G

C120LB-R8-3G

C120LB-R8-4G

C120LB-R8-5G

C120LB-R8-6G

C120LB-R8-7G

C120LB-R8-8G

C120LB-R8-9G

C120LB-R8-10G

C120LB-R8-11G

C120LB-R8-12G

C120LB-R8-13G

C120LB-R8-14G

C120LB-R8-15G

C120LB-R8-16G

C120LB-R8-17G

C120LB-R8-18G

C120LB-R8-19G

C120LB-R8-20G

C120LB-R8-21G

C120LB-R8-22G

C120LB-R8-23G

C120LB-R8-24G

C120LB-R8-25G

C120LB-R8-26G

C120LB-R8-27G

C120LB-R8-28G

C120LB-R8-29G

C120LB-R8-30G

82

82

82

82

82

82

82

82

82

82

82

82

82

82

82

82

82

82

82

82

82

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

C120LB-R8-31G

C120LB-R8-32G

C120LB-R10-4G

C120LB-R10-6G

C120LB-R10-8G

C120LB-R10-10G

C120LB-R10-12G

C120LB-R10-14G

C120LB-R10-16G

C120LB-R10-18G

C120LB-R10-20G

C120LB-R10-22G

C120LB-R10-24G

C120LB-R10-26G

C120LB-R10-28G

C120LB-R10-30G

C120LB-R10-32G

C120LB-R12-4G

C120LB-R12-6G

C120LB-R12-8G

C120LB-R12-10G

C120LB-R12-12G

C120LB-R12-14G

C120LB-R12-16G

C120LB-R12-18G

C120LB-R12-20G

C120LB-R12-22G

C120LB-R12-24G

C120LB-R12-26G

C120LB-R12-28G

C120LB-R12-30G

C120LB-R12-32G

C120LT-R6-2G

C120LT-R6-3G

C120LT-R6-4G

C120LT-R6-5G

C120LT-R6-6G

C120LT-R6-7G

C120LT-R6-8G

C120LT-R6-9G

C120LT-R6-10G

C120LT-R6-11G

C120LT-R6-12G

C120LT-R6-13G

C120LT-R6-14G

C120LT-R6-15G

C120LT-R6-16G

C120LT-R6-17G

C120LT-R6-18G

C120LT-R6-19G

83

83

84

84

84

84

84

84

84

84

84

84

84

84

84

84

84

85

85

85

85

85

85

85

85

85

85

85

85

85

85

85

86

86

86

86

86

86

86

86

86

86

86

86

86

86

86

86

86

86

C120LT-R6-20G

C120LT-R6-21G

C120LT-R6-22G

C120LT-R6-23G

C120LT-R6-24G

C120LT-R6-25G

C120LT-R6-26G

C120LT-R6-27G

C120LT-R6-28G

C120LT-R6-29G

C120LT-R6-30G

C120LT-R6-31G

C120LT-R6-32G

C120LT-R8-2G

C120LT-R8-3G

C120LT-R8-4G

C120LT-R8-5G

C120LT-R8-6G

C120LT-R8-7G

C120LT-R8-8G

C120LT-R8-9G

C120LT-R8-10G

C120LT-R8-11G

C120LT-R8-12G

C120LT-R8-13G

C120LT-R8-14G

C120LT-R8-15G

C120LT-R8-16G

C120LT-R8-17G

C120LT-R8-18G

C120LT-R8-19G

C120LT-R8-20G

C120LT-R8-21G

C120LT-R8-22G

C120LT-R8-23G

C120LT-R8-24G

C120LT-R8-25G

C120LT-R8-26G

C120LT-R8-27G

C120LT-R8-28G

C120LT-R8-29G

C120LT-R8-30G

C120LT-R8-31G

C120LT-R8-32G

C120LT-R10-4G

C120LT-R10-6G

C120LT-R10-8G

C120LT-R10-10G

C120LT-R10-12G

C120LT-R10-14G

86

86

86

86

86

86

86

86

86

86

86

86

86

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

87

88

88

88

88

88

88

Page 142: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

142

Numerical index®

C120LT-R10-16G

C120LT-R10-18G

C120LT-R10-20G

C120LT-R10-22G

C120LT-R10-24G

C120LT-R10-26G

C120LT-R10-28G

C120LT-R10-30G

C120LT-R10-32G

C120LT-R12-4G

C120LT-R12-6G

C120LT-R12-8G

C120LT-R12-10G

C120LT-R12-12G

C120LT-R12-14G

C120LT-R12-16G

C120LT-R12-18G

C120LT-R12-20G

C120LT-R12-22G

C120LT-R12-24G

C120LT-R12-26G

C120LT-R12-28G

C120LT-R12-30G

C120LT-R12-32G

C50L90-BR16-8

C50L90-BR16-12

C50L90-BR16-16

C50L90-BR16-20

C50L90-BR16-24

C50L90-BR16-28

C50L90-BR16-32

C50L90-BR16-36

C50L90-BR16-40

C50L90-BR16-44

C50L90-BR16-48

C50L90-BR16-52

C50L90-BR16-56

C50L90-BR16-60

C50L90-BR16-64

C50L90-BR20-8

C50L90-BR20-12

C50L90-BR20-16

C50L90-BR20-20

C50L90-BR20-24

C50L90-BR20-28

C50L90-BR20-32

C50L90-BR20-36

C50L90-BR20-40

C50L90-BR20-44

C50L90-BR20-48

88

88

88

88

88

88

88

88

88

89

89

89

89

89

89

89

89

89

89

89

89

89

89

89

102

102

102

102

102

102

102

102

102

102

102

102

102

102

102

103

103

103

103

103

103

103

103

103

103

103

C50L90-BR20-52

C50L90-BR20-56

C50L90-BR20-60

C50L90-BR20-64

C50L90-BR24-12

C50L90-BR24-16

C50L90-BR24-20

C50L90-BR24-24

C50L90-BR24-28

C50L90-BR24-32

C50L90-BR24-36

C50L90-BR24-40

C50L90-BR24-44

C50L90-BR24-48

C50L90-BR24-52

C50L90-BR24-56

C50L90-BR24-60

C50L90-BR24-64

C50LR-BR16-4

C50LR-BR16-8

C50LR-BR16-12

C50LR-BR16-16

C50LR-BR16-20

C50LR-BR16-24

C50LR-BR16-28

C50LR-BR16-32

C50LR-BR16-36

C50LR-BR16-40

C50LR-BR16-44

C50LR-BR16-48

C50LR-BR16-52

C50LR-BR16-56

C50LR-BR16-60

C50LR-BR16-64

C50LR-BR16-68

C50LR-BR16-72

C50LR-BR16-76

C50LR-BR16-80

C50LR-BR16-84

C50LR-BR16-88

C50LR-BR16-92

C50LR-BR20-4

C50LR-BR20-8

C50LR-BR20-12

C50LR-BR20-16

C50LR-BR20-20

C50LR-BR20-24

C50LR-BR20-28

C50LR-BR20-32

C50LR-BR20-36

103

103

103

103

104

104

104

104

104

104

104

104

104

104

104

104

104

104

94

94

94

94

94

94

94

94

94

94

94

94

94

94

94

94

94

94

94

94

94

94

94

95

95

95

95

95

95

95

95

95

C50LR-BR20-40

C50LR-BR20-44

C50LR-BR20-48

C50LR-BR20-52

C50LR-BR20-56

C50LR-BR20-60

C50LR-BR20-64

C50LR-BR20-68

C50LR-BR20-72

C50LR-BR20-76

C50LR-BR20-80

C50LR-BR20-84

C50LR-BR20-88

C50LR-BR20-92

C50LR-BR24-4

C50LR-BR24-8

C50LR-BR24-12

C50LR-BR24-16

C50LR-BR24-20

C50LR-BR24-24

C50LR-BR24-28

C50LR-BR24-32

C50LR-BR24-36

C50LR-BR24-40

C50LR-BR24-44

C50LR-BR24-48

C50LR-BR24-52

C50LR-BR24-56

C50LR-BR24-60

C50LR-BR24-64

C50LR-BR24-68

C50LR-BR24-72

C50LR-BR24-76

C50LR-BR24-80

C50LR-BR24-84

C50LR-BR24-88

C50LR-BR24-92

C50LR-BR28-8

C50LR-BR28-12

C50LR-BR28-16

C50LR-BR28-20

C50LR-BR28-24

C50LR-BR28-28

C50LR-BR28-32

C50LR-BR28-36

C50LR-BR28-40

C50LR-BR28-44

C50LR-BR28-48

C50LR-BR28-52

C50LR-BR28-56

95

95

95

95

95

95

95

95

95

95

95

95

95

95

96

96

96

96

96

96

96

96

96

96

96

96

96

96

96

96

96

96

96

96

96

96

96

97

97

97

97

97

97

97

97

97

97

97

97

97

C50LR-BR28-60

C50LR-BR28-64

C50LR-BR28-68

C50LR-BR28-72

C50LR-BR28-76

C50LR-BR28-80

C50LR-BR28-84

C50LR-BR28-88

C50LR-BR28-92

C50LR-BR32-8

C50LR-BR32-12

C50LR-BR32-16

C50LR-BR32-20

C50LR-BR32-24

C50LR-BR32-28

C50LR-BR32-32

C50LR-BR32-36

C50LR-BR32-40

C50LR-BR32-44

C50LR-BR32-48

C50LR-BR32-52

C50LR-BR32-56

C50LR-BR32-60

C50LR-BR32-64

C50LR-BR32-68

C50LR-BR32-72

C50LR-BR32-76

C50LR-BR32-80

C50LR-BR32-84

C50LR-BR32-88

C50LR-BR32-92

C50LR-BR36-28

C50LR-BR36-32

C50LR-BR36-36

C50LR-BR36-40

C50LR-BR36-44

C50LR-BR36-48

C50LR-BR36-52

C50LR-BR36-56

C50LR-BR36-60

C50LR-BR36-64

C50LR-BR36-68

C50LR-BR36-72

C50LR-BR36-76

C50LR-BR36-80

C50LR-BR36-84

C50LR-BR36-88

C50LR-BR36-92

C50LR-U16-4

C50LR-U16-8

97

97

97

97

97

97

97

97

97

98

98

98

98

98

98

98

98

98

98

98

98

98

98

98

98

98

98

98

98

98

98

99

99

99

99

99

99

99

99

99

99

99

99

99

99

99

99

99

100

100

C50LR-U16-12

C50LR-U16-16

C50LR-U16-20

C50LR-U16-24

C50LR-U20-4

C50LR-U20-8

C50LR-U20-12

C50LR-U20-16

C50LR-U20-20

C50LR-U20-24

C6L90-C6-3

C6L90-C6-4

C6L90-C6-5

C6L90-C6-6

C6L90-C6-7

C6L90-C6-8

C6L90-C6-9

C6L90-C6-10

C6L90-C6-11

C6L90-C6-12

C6L90-C6-13

C6L90-C6-14

C6L90-C6-15

C6L90-C6-16

C6L90-C6-17

C6L90-C6-18

C6L90-C6-19

C6L90-C6-20

C6L90-C6-21

C6L90-C6-22

C6L90-C6-23

C6L90-C6-24

C6L90-C6-25

C6L90-C6-26

C6L90-C6-27

C6L90-C6-28

C6L90-C6-29

C6L90-C6-30

C6L90-C6-31

C6L90-C6-32

C6L90-C8-3

C6L90-C8-4

C6L90-C8-5

C6L90-C8-6

C6L90-C8-7

C6L90-C8-8

C6L90-C8-9

C6L90-C8-10

C6L90-C8-11

C6L90-C8-12

100

100

100

100

101

101

101

101

101

101

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

58

59

59

59

59

59

59

59

59

59

59

Page 143: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

143

C6L90-C8-13

C6L90-C8-14

C6L90-C8-15

C6L90-C8-16

C6L90-C8-17

C6L90-C8-18

C6L90-C8-19

C6L90-C8-20

C6L90-C8-21

C6L90-C8-22

C6L90-C8-23

C6L90-C8-24

C6L90-C8-25

C6L90-C8-26

C6L90-C8-27

C6L90-C8-28

C6L90-C8-29

C6L90-C8-30

C6L90-C8-31

C6L90-C8-32

C6L90-C10-4

C6L90-C10-6

C6L90-C10-8

C6L90-C10-10

C6L90-C10-12

C6L90-C10-14

C6L90-C10-16

C6L90-C10-18

C6L90-C10-20

C6L90-C10-22

C6L90-C10-24

C6L90-C10-26

C6L90-C10-28

C6L90-C10-30

C6L90-C10-32

C6L90-C12-6

C6L90-C12-8

C6L90-C12-10

C6L90-C12-12

C6L90-C12-14

C6L90-C12-16

C6L90-C12-18

C6L90-C12-20

C6L90-C12-22

C6L90-C12-24

C6L90-C12-26

C6L90-C12-28

C6L90-C12-30

C6L90-C12-32

C6L90-F6-3

59

59

59

59

59

59

59

59

59

59

59

59

59

59

59

59

59

59

59

59

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

61

61

61

61

61

61

61

61

61

61

61

61

61

61

62

C6L90-F6-4

C6L90-F6-5

C6L90-F6-6

C6L90-F6-7

C6L90-F6-8

C6L90-F6-9

C6L90-F6-10

C6L90-F6-11

C6L90-F6-12

C6L90-F6-13

C6L90-F6-14

C6L90-F6-15

C6L90-F6-16

C6L90-F6-17

C6L90-F6-18

C6L90-F6-19

C6L90-F6-20

C6L90-F6-21

C6L90-F6-22

C6L90-F6-23

C6L90-F6-24

C6L90-F6-25

C6L90-F6-26

C6L90-F6-27

C6L90-F6-28

C6L90-F6-29

C6L90-F6-30

C6L90-F6-31

C6L90-F6-32

C6L90-F8-3

C6L90-F8-4

C6L90-F8-5

C6L90-F8-6

C6L90-F8-7

C6L90-F8-8

C6L90-F8-9

C6L90-F8-10

C6L90-F8-11

C6L90-F8-12

C6L90-F8-13

C6L90-F8-14

C6L90-F8-15

C6L90-F8-16

C6L90-F8-17

C6L90-F8-18

C6L90-F8-19

C6L90-F8-20

C6L90-F8-21

C6L90-F8-22

C6L90-F8-23

62

62

62

62

62

62

62

62

62

62

62

62

62

62

62

62

62

62

62

62

62

62

62

62

62

62

62

62

62

63

63

63

63

63

63

63

63

63

63

63

63

63

63

63

63

63

63

63

63

63

C6L90-F8-24

C6L90-F8-25

C6L90-F8-26

C6L90-F8-27

C6L90-F8-28

C6L90-F8-29

C6L90-F8-30

C6L90-F8-31

C6L90-F8-32

C6L90-F10-4

C6L90-F10-6

C6L90-F10-8

C6L90-F10-10

C6L90-F10-12

C6L90-F10-14

C6L90-F10-16

C6L90-F10-18

C6L90-F10-20

C6L90-F10-22

C6L90-F10-24

C6L90-F10-26

C6L90-F10-28

C6L90-F10-30

C6L90-F10-32

C6L90-F12-6

C6L90-F12-8

C6L90-F12-10

C6L90-F12-12

C6L90-F12-14

C6L90-F12-16

C6L90-F12-18

C6L90-F12-20

C6L90-F12-22

C6L90-F12-24

C6L90-F12-26

C6L90-F12-28

C6L90-F12-30

C6L90-F12-32

C6L90-R6-3G

C6L90-R6-4G

C6L90-R6-5G

C6L90-R6-6G

C6L90-R6-7G

C6L90-R6-8G

C6L90-R6-9G

C6L90-R6-10G

C6L90-R6-11G

C6L90-R6-12G

C6L90-R6-13G

C6L90-R6-14G

63

63

63

63

63

63

63

63

63

64

64

64

64

64

64

64

64

64

64

64

64

64

64

64

65

65

65

65

65

65

65

65

65

65

65

65

65

65

50

50

50

50

50

50

50

50

50

50

50

50

C6L90-R6-15G

C6L90-R6-16G

C6L90-R6-17G

C6L90-R6-18G

C6L90-R6-19G

C6L90-R6-20G

C6L90-R6-21G

C6L90-R6-22G

C6L90-R6-23G

C6L90-R6-24G

C6L90-R6-25G

C6L90-R6-26G

C6L90-R6-27G

C6L90-R6-28G

C6L90-R6-29G

C6L90-R6-30G

C6L90-R6-31G

C6L90-R6-32G

C6L90-R8-3G

C6L90-R8-4G

C6L90-R8-5G

C6L90-R8-6G

C6L90-R8-7G

C6L90-R8-8G

C6L90-R8-9G

C6L90-R8-10G

C6L90-R8-11G

C6L90-R8-12G

C6L90-R8-13G

C6L90-R8-14G

C6L90-R8-15G

C6L90-R8-16G

C6L90-R8-17G

C6L90-R8-18G

C6L90-R8-19G

C6L90-R8-20G

C6L90-R8-21G

C6L90-R8-22G

C6L90-R8-23G

C6L90-R8-24G

C6L90-R8-25G

C6L90-R8-26G

C6L90-R8-27G

C6L90-R8-28G

C6L90-R8-29G

C6L90-R8-30G

C6L90-R8-31G

C6L90-R8-32G

C6L90-R10-4G

C6L90-R10-6G

50

50

50

50

50

50

50

50

50

50

50

50

50

50

50

50

50

50

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

51

52

52

C6L90-R10-8G

C6L90-R10-10G

C6L90-R10-12G

C6L90-R10-14G

C6L90-R10-16G

C6L90-R10-18G

C6L90-R10-20G

C6L90-R10-22G

C6L90-R10-24G

C6L90-R10-26G

C6L90-R10-28G

C6L90-R10-30G

C6L90-R10-32G

C6L90-R12-6G

C6L90-R12-8G

C6L90-R12-10G

C6L90-R12-12G

C6L90-R12-14G

C6L90-R12-16G

C6L90-R12-18G

C6L90-R12-20G

C6L90-R12-22G

C6L90-R12-24G

C6L90-R12-26G

C6L90-R12-28G

C6L90-R12-30G

C6L90-R12-32G

C6L90-U6-3

C6L90-U6-4

C6L90-U6-5

C6L90-U6-6

C6L90-U6-7

C6L90-U6-8

C6L90-U6-9

C6L90-U6-10

C6L90-U6-11

C6L90-U6-12

C6L90-U6-13

C6L90-U6-14

C6L90-U6-15

C6L90-U6-16

C6L90-U6-17

C6L90-U6-18

C6L90-U6-19

C6L90-U6-20

C6L90-U6-21

C6L90-U6-22

C6L90-U6-23

C6L90-U6-24

C6L90-U6-25

52

52

52

52

52

52

52

52

52

52

52

52

52

53

53

53

53

53

53

53

53

53

53

53

53

53

53

54

54

54

54

54

54

54

54

54

54

54

54

54

54

54

54

54

54

54

54

54

54

54

Page 144: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

144

Numerical index®

C6L90-U6-26

C6L90-U6-27

C6L90-U6-28

C6L90-U6-29

C6L90-U6-30

C6L90-U6-31

C6L90-U6-32

C6L90-U8-3

C6L90-U8-4

C6L90-U8-5

C6L90-U8-6

C6L90-U8-7

C6L90-U8-8

C6L90-U8-9

C6L90-U8-10

C6L90-U8-11

C6L90-U8-12

C6L90-U8-13

C6L90-U8-14

C6L90-U8-15

C6L90-U8-16

C6L90-U8-17

C6L90-U8-18

C6L90-U8-19

C6L90-U8-20

C6L90-U8-21

C6L90-U8-22

C6L90-U8-23

C6L90-U8-24

C6L90-U8-25

C6L90-U8-26

C6L90-U8-27

C6L90-U8-28

C6L90-U8-29

C6L90-U8-30

C6L90-U8-31

C6L90-U8-32

C6L90-U10-4

C6L90-U10-6

C6L90-U10-8

C6L90-U10-10

C6L90-U10-12

C6L90-U10-14

C6L90-U10-16

C6L90-U10-18

C6L90-U10-20

C6L90-U10-22

C6L90-U10-24

C6L90-U10-26

C6L90-U10-28

54

54

54

54

54

54

54

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

55

56

56

56

56

56

56

56

56

56

56

56

56

56

C6L90-U10-30

C6L90-U10-32

C6L90-U12-6

C6L90-U12-8

C6L90-U12-10

C6L90-U12-12

C6L90-U12-14

C6L90-U12-16

C6L90-U12-18

C6L90-U12-20

C6L90-U12-22

C6L90-U12-24

C6L90-U12-26

C6L90-U12-28

C6L90-U12-30

C6L90-U12-32

C6LB-F6-2

C6LB-F6-3

C6LB-F6-4

C6LB-F6-5

C6LB-F6-6

C6LB-F6-7

C6LB-F6-8

C6LB-F6-9

C6LB-F6-10

C6LB-F6-11

C6LB-F6-12

C6LB-F6-13

C6LB-F6-14

C6LB-F6-15

C6LB-F6-16

C6LB-F6-17

C6LB-F6-18

C6LB-F6-19

C6LB-F6-20

C6LB-F6-21

C6LB-F6-22

C6LB-F6-23

C6LB-F6-24

C6LB-F6-25

C6LB-F6-26

C6LB-F6-27

C6LB-F6-28

C6LB-F6-29

C6LB-F6-30

C6LB-F6-31

C6LB-F6-32

C6LB-F8-2

C6LB-F8-3

C6LB-F8-4

56

56

57

57

57

57

57

57

57

57

57

57

57

57

57

57

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

46

47

47

47

C6LB-F8-5

C6LB-F8-6

C6LB-F8-7

C6LB-F8-8

C6LB-F8-9

C6LB-F8-10

C6LB-F8-11

C6LB-F8-12

C6LB-F8-13

C6LB-F8-14

C6LB-F8-15

C6LB-F8-16

C6LB-F8-17

C6LB-F8-18

C6LB-F8-19

C6LB-F8-20

C6LB-F8-21

C6LB-F8-22

C6LB-F8-23

C6LB-F8-24

C6LB-F8-25

C6LB-F8-26

C6LB-F8-27

C6LB-F8-28

C6LB-F8-29

C6LB-F8-30

C6LB-F8-31

C6LB-F8-32

C6LB-F10-4

C6LB-F10-6

C6LB-F10-8

C6LB-F10-10

C6LB-F10-12

C6LB-F10-14

C6LB-F10-16

C6LB-F10-18

C6LB-F10-20

C6LB-F10-22

C6LB-F10-24

C6LB-F10-26

C6LB-F10-28

C6LB-F10-30

C6LB-F10-32

C6LB-F12-4

C6LB-F12-6

C6LB-F12-8

C6LB-F12-10

C6LB-F12-12

C6LB-F12-14

C6LB-F12-16

47

47

47

47

47

47

47

47

47

47

47

47

47

47

47

47

47

47

47

47

47

47

47

47

47

47

47

47

48

48

48

48

48

48

48

48

48

48

48

48

48

48

48

49

49

49

49

49

49

49

C6LB-F12-18

C6LB-F12-20

C6LB-F12-22

C6LB-F12-24

C6LB-F12-26

C6LB-F12-28

C6LB-F12-30

C6LB-F12-32

C6LB-R6-2G

C6LB-R6-3G

C6LB-R6-4G

C6LB-R6-5G

C6LB-R6-6G

C6LB-R6-7G

C6LB-R6-8G

C6LB-R6-9G

C6LB-R6-10G

C6LB-R6-11G

C6LB-R6-12G

C6LB-R6-13G

C6LB-R6-14G

C6LB-R6-15G

C6LB-R6-16G

C6LB-R6-17G

C6LB-R6-18G

C6LB-R6-19G

C6LB-R6-20G

C6LB-R6-21G

C6LB-R6-22G

C6LB-R6-23G

C6LB-R6-24G

C6LB-R6-25G

C6LB-R6-26G

C6LB-R6-27G

C6LB-R6-28G

C6LB-R6-29G

C6LB-R6-30G

C6LB-R6-31G

C6LB-R6-32G

C6LB-R8-2G

C6LB-R8-3G

C6LB-R8-4G

C6LB-R8-5G

C6LB-R8-6G

C6LB-R8-7G

C6LB-R8-8G

C6LB-R8-9G

C6LB-R8-10G

C6LB-R8-11G

C6LB-R8-12G

49

49

49

49

49

49

49

49

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

38

39

39

39

39

39

39

39

39

39

39

39

C6LB-R8-13G

C6LB-R8-14G

C6LB-R8-15G

C6LB-R8-16G

C6LB-R8-17G

C6LB-R8-18G

C6LB-R8-19G

C6LB-R8-20G

C6LB-R8-21G

C6LB-R8-22G

C6LB-R8-23G

C6LB-R8-24G

C6LB-R8-25G

C6LB-R8-26G

C6LB-R8-27G

C6LB-R8-28G

C6LB-R8-29G

C6LB-R8-30G

C6LB-R8-31G

C6LB-R8-32G

C6LB-R10-4G

C6LB-R10-6G

C6LB-R10-8G

C6LB-R10-10G

C6LB-R10-12G

C6LB-R10-14G

C6LB-R10-16G

C6LB-R10-18G

C6LB-R10-20G

C6LB-R10-22G

C6LB-R10-24G

C6LB-R10-26G

C6LB-R10-28G

C6LB-R10-30G

C6LB-R10-32G

C6LB-R12-4G

C6LB-R12-6G

C6LB-R12-8G

C6LB-R12-10G

C6LB-R12-12G

C6LB-R12-14G

C6LB-R12-16G

C6LB-R12-18G

C6LB-R12-20G

C6LB-R12-22G

C6LB-R12-24G

C6LB-R12-26G

C6LB-R12-28G

C6LB-R12-30G

C6LB-R12-32G

39

39

39

39

39

39

39

39

39

39

39

39

39

39

39

39

39

39

39

39

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

41

41

41

41

41

41

41

41

41

41

41

41

41

41

41

Page 145: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

145

C6LB-U6-2

C6LB-U6-3

C6LB-U6-4

C6LB-U6-5

C6LB-U6-6

C6LB-U6-7

C6LB-U6-8

C6LB-U6-9

C6LB-U6-10

C6LB-U6-11

C6LB-U6-12

C6LB-U6-13

C6LB-U6-14

C6LB-U6-15

C6LB-U6-16

C6LB-U6-17

C6LB-U6-18

C6LB-U6-19

C6LB-U6-20

C6LB-U6-21

C6LB-U6-22

C6LB-U6-23

C6LB-U6-24

C6LB-U6-25

C6LB-U6-26

C6LB-U6-27

C6LB-U6-28

C6LB-U6-29

C6LB-U6-30

C6LB-U6-31

C6LB-U6-32

C6LB-U8-2

C6LB-U8-3

C6LB-U8-4

C6LB-U8-5

C6LB-U8-6

C6LB-U8-7

C6LB-U8-8

C6LB-U8-9

C6LB-U8-10

C6LB-U8-11

C6LB-U8-12

C6LB-U8-13

C6LB-U8-14

C6LB-U8-15

C6LB-U8-16

C6LB-U8-17

C6LB-U8-18

C6LB-U8-19

C6LB-U8-20

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

42

43

43

43

43

43

43

43

43

43

43

43

43

43

43

43

43

43

43

43

C6LB-U8-21

C6LB-U8-22

C6LB-U8-23

C6LB-U8-24

C6LB-U8-25

C6LB-U8-26

C6LB-U8-27

C6LB-U8-28

C6LB-U8-29

C6LB-U8-30

C6LB-U8-31

C6LB-U8-32

C6LB-U10-4

C6LB-U10-6

C6LB-U10-8

C6LB-U10-10

C6LB-U10-12

C6LB-U10-14

C6LB-U10-16

C6LB-U10-18

C6LB-U10-20

C6LB-U10-22

C6LB-U10-24

C6LB-U10-26

C6LB-U10-28

C6LB-U10-30

C6LB-U10-32

C6LB-U12-4

C6LB-U12-6

C6LB-U12-8

C6LB-U12-10

C6LB-U12-12

C6LB-U12-14

C6LB-U12-16

C6LB-U12-18

C6LB-U12-20

C6LB-U12-22

C6LB-U12-24

C6LB-U12-26

C6LB-U12-28

C6LB-U12-30

C6LB-U12-32

C6LT-C6-2

C6LT-C6-3

C6LT-C6-4

C6LT-C6-5

C6LT-C6-6

C6LT-C6-7

C6LT-C6-8

C6LT-C6-9

43

43

43

43

43

43

43

43

43

43

43

43

44

44

44

44

44

44

44

44

44

44

44

44

44

44

44

45

45

45

45

45

45

45

45

45

45

45

45

45

45

45

74

74

74

74

74

74

74

74

C6LT-C6-10

C6LT-C6-11

C6LT-C6-12

C6LT-C6-13

C6LT-C6-14

C6LT-C6-15

C6LT-C6-16

C6LT-C6-17

C6LT-C6-18

C6LT-C6-19

C6LT-C6-20

C6LT-C6-21

C6LT-C6-22

C6LT-C6-23

C6LT-C6-24

C6LT-C6-25

C6LT-C6-26

C6LT-C6-27

C6LT-C6-28

C6LT-C6-29

C6LT-C6-30

C6LT-C6-31

C6LT-C6-32

C6LT-C8-2

C6LT-C8-3

C6LT-C8-4

C6LT-C8-5

C6LT-C8-6

C6LT-C8-7

C6LT-C8-8

C6LT-C8-9

C6LT-C8-10

C6LT-C8-11

C6LT-C8-12

C6LT-C8-13

C6LT-C8-14

C6LT-C8-15

C6LT-C8-16

C6LT-C8-17

C6LT-C8-18

C6LT-C8-19

C6LT-C8-20

C6LT-C8-21

C6LT-C8-22

C6LT-C8-23

C6LT-C8-24

C6LT-C8-25

C6LT-C8-26

C6LT-C8-27

C6LT-C8-28

74

74

74

74

74

74

74

74

74

74

74

74

74

74

74

74

74

74

74

74

74

74

74

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

75

C6LT-C8-29

C6LT-C8-30

C6LT-C8-31

C6LT-C8-32

C6LT-C10-4

C6LT-C10-6

C6LT-C10-8

C6LT-C10-10

C6LT-C10-12

C6LT-C10-14

C6LT-C10-16

C6LT-C10-18

C6LT-C10-20

C6LT-C10-22

C6LT-C10-24

C6LT-C10-26

C6LT-C10-28

C6LT-C10-30

C6LT-C10-32

C6LT-C12-4

C6LT-C12-6

C6LT-C12-8

C6LT-C12-10

C6LT-C12-12

C6LT-C12-14

C6LT-C12-16

C6LT-C12-18

C6LT-C12-20

C6LT-C12-22

C6LT-C12-24

C6LT-C12-26

C6LT-C12-28

C6LT-C12-30

C6LT-C12-32

C6LT-F6-2

C6LT-F6-3

C6LT-F6-4

C6LT-F6-5

C6LT-F6-6

C6LT-F6-7

C6LT-F6-8

C6LT-F6-9

C6LT-F6-10

C6LT-F6-11

C6LT-F6-12

C6LT-F6-13

C6LT-F6-14

C6LT-F6-15

C6LT-F6-16

C6LT-F6-17

75

75

75

75

76

76

76

76

76

76

76

76

76

76

76

76

76

76

76

77

77

77

77

77

77

77

77

77

77

77

77

77

77

77

78

78

78

78

78

78

78

78

78

78

78

78

78

78

78

78

C6LT-F6-18

C6LT-F6-19

C6LT-F6-20

C6LT-F6-21

C6LT-F6-22

C6LT-F6-23

C6LT-F6-24

C6LT-F6-25

C6LT-F6-26

C6LT-F6-27

C6LT-F6-28

C6LT-F6-29

C6LT-F6-30

C6LT-F6-31

C6LT-F6-32

C6LT-F8-2

C6LT-F8-3

C6LT-F8-4

C6LT-F8-5

C6LT-F8-6

C6LT-F8-7

C6LT-F8-8

C6LT-F8-9

C6LT-F8-10

C6LT-F8-11

C6LT-F8-12

C6LT-F8-13

C6LT-F8-14

C6LT-F8-15

C6LT-F8-16

C6LT-F8-17

C6LT-F8-18

C6LT-F8-19

C6LT-F8-20

C6LT-F8-21

C6LT-F8-22

C6LT-F8-23

C6LT-F8-24

C6LT-F8-25

C6LT-F8-26

C6LT-F8-27

C6LT-F8-28

C6LT-F8-29

C6LT-F8-30

C6LT-F8-31

C6LT-F8-32

C6LT-F10-4

C6LT-F10-6

C6LT-F10-8

C6LT-F10-10

78

78

78

78

78

78

78

78

78

78

78

78

78

78

78

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

79

80

80

80

80

Page 146: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

146

Numerical index®

C6LT-F10-12

C6LT-F10-14

C6LT-F10-16

C6LT-F10-18

C6LT-F10-20

C6LT-F10-22

C6LT-F10-24

C6LT-F10-26

C6LT-F10-28

C6LT-F10-30

C6LT-F10-32

C6LT-F12-4

C6LT-F12-6

C6LT-F12-8

C6LT-F12-10

C6LT-F12-12

C6LT-F12-14

C6LT-F12-16

C6LT-F12-18

C6LT-F12-20

C6LT-F12-22

C6LT-F12-24

C6LT-F12-26

C6LT-F12-28

C6LT-F12-30

C6LT-F12-32

C6LT-R6-2G

C6LT-R6-3G

C6LT-R6-4G

C6LT-R6-5G

C6LT-R6-6G

C6LT-R6-7G

C6LT-R6-8G

C6LT-R6-9G

C6LT-R6-10G

C6LT-R6-11G

C6LT-R6-12G

C6LT-R6-13G

C6LT-R6-14G

C6LT-R6-15G

C6LT-R6-16G

C6LT-R6-17G

C6LT-R6-18G

C6LT-R6-19G

C6LT-R6-20G

C6LT-R6-21G

C6LT-R6-22G

C6LT-R6-23G

C6LT-R6-24G

C6LT-R6-25G

80

80

80

80

80

80

80

80

80

80

80

81

81

81

81

81

81

81

81

81

81

81

81

81

81

81

66

66

66

66

66

66

66

66

66

66

66

66

66

66

66

66

66

66

66

66

66

66

66

66

C6LT-R6-26G

C6LT-R6-27G

C6LT-R6-28G

C6LT-R6-29G

C6LT-R6-30G

C6LT-R6-31G

C6LT-R6-32G

C6LT-R8-2G

C6LT-R8-3G

C6LT-R8-4G

C6LT-R8-5G

C6LT-R8-6G

C6LT-R8-7G

C6LT-R8-8G

C6LT-R8-9G

C6LT-R8-10G

C6LT-R8-11G

C6LT-R8-12G

C6LT-R8-13G

C6LT-R8-14G

C6LT-R8-15G

C6LT-R8-16G

C6LT-R8-17G

C6LT-R8-18G

C6LT-R8-19G

C6LT-R8-20G

C6LT-R8-21G

C6LT-R8-22G

C6LT-R8-23G

C6LT-R8-24G

C6LT-R8-25G

C6LT-R8-26G

C6LT-R8-27G

C6LT-R8-28G

C6LT-R8-29G

C6LT-R8-30G

C6LT-R8-31G

C6LT-R8-32G

C6LT-R10-4G

C6LT-R10-6G

C6LT-R10-8G

C6LT-R10-10G

C6LT-R10-12G

C6LT-R10-14G

C6LT-R10-16G

C6LT-R10-18G

C6LT-R10-20G

C6LT-R10-22G

C6LT-R10-24G

C6LT-R10-26G

66

66

66

66

66

66

66

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

67

68

68

68

68

68

68

68

68

68

68

68

68

C6LT-R10-28G

C6LT-R10-30G

C6LT-R10-32G

C6LT-R12-4G

C6LT-R12-6G

C6LT-R12-8G

C6LT-R12-10G

C6LT-R12-12G

C6LT-R12-14G

C6LT-R12-16G

C6LT-R12-18G

C6LT-R12-20G

C6LT-R12-22G

C6LT-R12-24G

C6LT-R12-26G

C6LT-R12-28G

C6LT-R12-30G

C6LT-R12-32G

C6LT-U6-2

C6LT-U6-3

C6LT-U6-4

C6LT-U6-5

C6LT-U6-6

C6LT-U6-7

C6LT-U6-8

C6LT-U6-9

C6LT-U6-10

C6LT-U6-11

C6LT-U6-12

C6LT-U6-13

C6LT-U6-14

C6LT-U6-15

C6LT-U6-16

C6LT-U6-17

C6LT-U6-18

C6LT-U6-19

C6LT-U6-20

C6LT-U6-21

C6LT-U6-22

C6LT-U6-23

C6LT-U6-24

C6LT-U6-25

C6LT-U6-26

C6LT-U6-27

C6LT-U6-28

C6LT-U6-29

C6LT-U6-30

C6LT-U6-31

C6LT-U6-32

C6LT-U8-2

68

68

68

69

69

69

69

69

69

69

69

69

69

69

69

69

69

69

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

70

71

C6LT-U8-3

C6LT-U8-4

C6LT-U8-5

C6LT-U8-6

C6LT-U8-7

C6LT-U8-8

C6LT-U8-9

C6LT-U8-10

C6LT-U8-11

C6LT-U8-12

C6LT-U8-13

C6LT-U8-14

C6LT-U8-15

C6LT-U8-16

C6LT-U8-17

C6LT-U8-18

C6LT-U8-19

C6LT-U8-20

C6LT-U8-21

C6LT-U8-22

C6LT-U8-23

C6LT-U8-24

C6LT-U8-25

C6LT-U8-26

C6LT-U8-27

C6LT-U8-28

C6LT-U8-29

C6LT-U8-30

C6LT-U8-31

C6LT-U8-32

C6LT-U10-4

C6LT-U10-6

C6LT-U10-8

C6LT-U10-10

C6LT-U10-12

C6LT-U10-14

C6LT-U10-16

C6LT-U10-18

C6LT-U10-20

C6LT-U10-22

C6LT-U10-24

C6LT-U10-26

C6LT-U10-28

C6LT-U10-30

C6LT-U10-32

C6LT-U12-4

C6LT-U12-6

C6LT-U12-8

C6LT-U12-10

C6LT-U12-12

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

71

72

72

72

72

72

72

72

72

72

72

72

72

72

72

72

73

73

73

73

73

C6LT-U12-14

C6LT-U12-16

C6LT-U12-18

C6LT-U12-20

C6LT-U12-22

C6LT-U12-24

C6LT-U12-26

C6LT-U12-28

C6LT-U12-30

C6LT-U12-32

HKLP-R6-5U

HKLP-R6-7

HKLP-R8-8,5

HKLP-R8-6*

HKLP-R8-7

HKLP-R8-10

HKLP-R8-12

HKLP-R8-14

HKLP-R8-18

HKLP-R8-20

HLPEG-R12-7

HLPEG-R12-8

HLPEG-R12-9

HLPEG-R12-10

HLPEG-R12-11

HLPEG-R12-12

HLPEG-R12-13

HLPEG-R12-14

HLPEG-R12-15

HLPEG-R12-16

HLPEG-R12-17

HLPEG-R12-18

HLPEG-R12-19

HLPEG-R12-20

HLPEG-R12-21

HLPEG-R12-22

HLPEG-R12-23

HLPEG-R12-24

HLPEG-R12-25

HLPEG-R12-26

HLPEG-R12-27

HLPEG-R12-28

HLPEG-R12-29

HLPMG-R12-10

HLPMG-R12-11

HLPMG-R12-12

HLPMG-R12-13

HLPMG-R12-14

HLPMG-R12-15

HLPMG-R12-16

73

73

73

73

73

73

73

73

73

73

23

23

23

23

23

23

23

23

23

23

109

109

109

108

108

108

108

108

108

108

108

108

108

108

108

108

108

108

108

108

108

108

108

107

107

107

107

107

107

107

Page 147: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

147

HLPMG-R12-17

HLPMG-R12-18

HLPMG-R12-19

HLPMG-R12-20

HLPMG-R12-21

HLPMG-R12-22

HLPMG-R12-23

HLPMG-R12-24

HLPMG-R12-25

HLPMG-R12-26

HLPMG-R12-27

HLPMG-R12-28

HLPMG-R12-29

HLPMG-R12-30

HLPPLS-R12-10

HLPPLS-R12-11

HLPPLS-R12-12

HLPPLS-R12-13

HLPPLS-R12-14

HLPPLS-R12-15

HLPPLS-R12-16

HLPPLS-R12-17

HLPPLS-R12-18

HLPPLS-R12-19

HLPPLS-R12-20

HLPPLS-R12-21

HLPPLS-R12-22

HLPPLS-R12-23

HLPPLS-R12-24

HLPPLS-R12-25

HLPPLS-R12-26

HLPPLS-R12-27

HLPPLS-R12-28

HLPPLS-R12-29

HLPPLS-R12-30

HLPSC-R12

HLPSGC-R12

HLPSGM-R12

HLPSG-R12-8

HLPSG-R12-9

HLPSGS-R12

HLPSM-R12

HLPS-R12

HLPS-R12XA

LC-2R16G

LC-2R20G

LC-2R24G

LC-2R28G

LC-2R32G

LC-2R36G

107

107

107

107

107

107

107

107

107

107

107

107

107

107

106

106

106

106

106

106

106

106

106

106

106

106

106

106

106

106

106

106

106

106

106

106-107-109

105-108

105-108

105

105

105-108

106-107-109

106-107-109

106-107-109

94-102

95-103

96-104

97

98

99

LC-I6

LC-I8

LC-I10

LC-I12

MBCP-R6-M2

MBCP-R6-M3

MBCP-R6-M4

MBCP-R6-M5

MBCP-R6-M6

MBCP-R6-M7

MBCP-R6-M8

MBCP-R6-M9

MBCP-R6-M10

MBCP-R8-M2

MBCP-R8-M3

MBCP-R8-M4

MBCP-R8-M5

MBCP-R8-M6

MBCP-R8-M7

MBCP-R8-M8

MBCP-R8-M9

MBCP-R8-M11

MBCP-R8-M13

MBCP-R8-M16

MBCP-R8-M19

MBCP-R8-M25

MBCP-R8-M31

MBP-R6-M2

MBP-R6-M3

MBP-R6-M4

MBP-R6-M5

MBP-R6-M6

MBP-R6-M7

MBP-R6-M8

MBP-R6-M9

MBP-R6-M10

MBP-R6-M11

MBP-R6-M12

MBP-R6-M13

MBP-R6-M14

MBP-R8-M2

MBP-R8-M3

MBP-R8-M4

MBP-R8-M5

MBP-R8-M6

MBP-R8-M7

MBP-R8-M8

MBP-R8-M9

MBP-R8-M10

MBP-R8-M11

46-62-78

47-63-79

48-64-80

49-65-81

22

22

22

22

22

22

22

22

22

22

22

22

22

22

22

22

22

22

22

22

22

22

22

21

21

21

21

21

21

21

21

21

21

21

21

21

21

21

21

21

21

21

21

21

21

21

MBP-R8-M12

MBP-R8-M13

MBP-R8-M19

MBP-R8-M32

MBP-R10-3

MBP-R10-4

MBP-R10-5

MBP-R10-6

MBP-R10-7

MBP-R10-8

MBP-R10-9

MBP-R10-10

MBTC-R12BL

MBTC-R14BL

MBTC-R16BL

MBTC-R20BL

MBT-DT12-10

MBT-DT12-15

MBT-DT12-20

MBT-DT12-25

MBT-DT12-30

MBT-DT12-35

MBT-DT12-40

MBT-DT12-45

MBT-DT12-50

MBT-DT12-55

MBT-DT12-60

MBT-DT12-65

MBT-DT12-70

MBT-DT12-75

MBT-DT12-80

MBT-DT14-10

MBT-DT14-15

MBT-DT14-20

MBT-DT14-25

MBT-DT14-30

MBT-DT14-35

MBT-DT14-40

MBT-DT14-45

MBT-DT14-50

MBT-DT14-55

MBT-DT14-60

MBT-DT14-65

MBT-DT14-70

MBT-DT14-75

MBT-DT14-80

MBT-DT16-10

MBT-DT16-15

MBT-DT16-20

MBT-DT16-25

21

21

21

21

21

21

21

21

21

21

21

21

112

113

114

115

112

112

112

112

112

112

112

112

112

112

112

112

112

112

112

113

113

113

113

113

113

113

113

113

113

113

113

113

113

113

114

114

114

114

MBT-DT16-30

MBT-DT16-35

MBT-DT16-40

MBT-DT16-45

MBT-DT16-50

MBT-DT16-55

MBT-DT16-60

MBT-DT16-65

MBT-DT16-70

MBT-DT16-75

MBT-DT16-80

MBT-DT20-10

MBT-DT20-15

MBT-DT20-20

MBT-DT20-25

MBT-DT20-30

MBT-DT20-35

MBT-DT20-40

MBT-DT20-45

MBT-DT20-50

MBT-DT20-55

MBT-DT20-60

MBT-DT20-65

MBT-DT20-70

MBT-DT20-75

MBT-DT20-80

MGC-F6

MGC-F8

MGC-F10

MGC-F12

MGC-R6U

MGC-R8U

MGC-R10U

MGC-R12U

MGCS-F6

MGCS-F8

MGCS-R6U

MGCS-R8U

MGCW-F6

MGCW-F8

MGCW-R6U

MGCW-R8U

MGL100-B6-6

MGL100-B6-9

MGL100-B6-12

MGL100-B6-14

MGL100-B8-8

MGL100-B8-12

MGL100-B8-E17

MGL100-R6-6

114

114

114

114

114

114

114

114

114

114

114

115

115

115

115

115

115

115

115

115

115

115

115

115

115

115

29-31-33

29-31-35-37

29-31-35

29-31-35-37

28-30-32

28-30-34-36

28-30-34

28-30-34-36

29-31-33

29-31-35-37

28-30-32

28-30-34-36

29-31-33

29-31-35-37

28-30-32

28-30-34-36

15

15

15

15

15

15

15

14

MGL100-R6-9

MGL100-R12-12

MGL100-R16-12

MGL100-R8-8

MGL100-R8-12

MGL100-U6-6

MGL100-U6-9

MGL100-U8-8

MGL100-U8-12

MGLP-316U8-6

MGLP-4U12-12

MGLP-B6-4

MGLP-B6-7

MGLP-B6-12

MGLP-B6-E

MGLP-B8-4

MGLP-B8-6

MGLP-B8-10

MGLP-B8-14

MGLP-B8-18

MGLP-B8-22

MGLP-B8-E

MGLP-B12-12

MGLP-B12-18

MGLP-B12-24

MGLP-B16-12

MGLP-R6-4

MGLP-R6-7

MGLP-R6-12

MGLP-R6-E

MGLP-R8-6

MGLP-R8-10

MGLP-R8-14

MGLP-R8-18

MGLP-R8-22

MGLP-R8-E

MGLP-R12-12

MGLP-R12-18

MGLP-R12-24

MGLP-R16-12

MGLP-U6-4

MGLP-U6-7

MGLP-U6-10

MGLP-U6-E

MGLP-U6-E8

MGLP-U6-E9

MGLP-U6-E10

MGLP-U8-4

MGLP-U8-6

MGLP-U8-7

14

14

14

14

14

16

16

16

16

10

10

8

8

8

8

8

8

8

8

8

8

8

8

8

8

8

9

9

9

9

9

9

9

9

9

9

9

9

9

9

10

10

10

10

10

10

10

10

10

10

Page 148: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

148

Numerical index®

MGLP-U8-10

MGLP-U8-E

MGLP-U12-18

MGLT-B6-4

MGLT-B6-7

MGLT-B6-E

MGLT-B8-6

MGLT-B8-10

MGLT-B8-E

MGLT-B12-12

MGLT-B12-24

MGLT-R6-4

MGLT-R6-7

MGLT-R6-E

MGLT-R8-6

MGLT-R8-10

MGLT-R8-E

MGLT-U8-6

MGLT-U8-10

MGLT-U8-E

MGP30-E8-10

MGP30-E8-24

MGP30-E12-24

MGP30-E12-32

MGP30-R8-10G

MGP30-R8-24G

MGP30-R12-24G

MGP30-R12-32G

MGP90-E6-10

MGP90-E6-20

MGP90-E8-10

MGP90-E8-20

MGP90-E10-12

MGP90-E10-22

MGP90-E12-14

MGP90-E12-26

MGP90-R6-10G

MGP90-R6-20G

MGP90-R8-10G

MGP90-R8-20G

MGP90-R10-12G

MGP90-R10-22G

MGP90-R12-14G

MGP90-R12-26G

MGP98T-E6-10

MGP98T-E6-20

MGP98T-R6-10G

MGP98T-R6-20G

MGPB-E6-10

MGPB-E6-20

10

10

10

11

11

11

11

11

11

11

11

12

12

12

12

12

12

13

13

13

37

37

37

37

36

36

36

36

31

31

31

31

31

31

31

31

30

30

30

30

30

30

30

30

33

33

32

32

29

29

MGPB-E8-10

MGPB-E8-20

MGPB-E10-12

MGPB-E10-22

MGPB-E12-14

MGPB-E12-26

MGPB-R6-10G

MGPB-R6-20G

MGPB-R8-10G

MGPB-R8-20G

MGPB-R10-12G

MGPB-R10-22G

MGPB-R12-14G

MGPB-R12-26G

MGPT-E8-10

MGPT-E8-20

MGPT-E10-12

MGPT-E10-22

MGPT-E12-14

MGPT-E12-26

MGPT-R8-10G

MGPT-R8-20G

MGPT-R10-12G

MGPT-R10-22G

MGPT-R12-14G

MGPT-R12-26G

MTLP-B6-4

MTLP-B6-8

MTLP-B6-12

MTLP-B6-12X

MTP-B6-5S

MTP-B6-6S

MTP-B6-8S

MTP-B6-10S

MTP-B6-12S

MTP-B8-4S

MTP-B8-6S

MTP-B8-7S

MTP-B8-8S

MTP-B8-10S

MTP-B8-12S

MTV-B6-5S

MTV-B6-7S

MTV-B6-8S

MTV-B6-10S

MTV-B6-12S

PMF-R10-20

PMF-R10-26

PWFLC-R10-20

PWFLC-R10-26

29

29

29

29

29

29

28

28

28

28

28

28

28

28

35

35

35

35

35

35

34

34

34

34

34

34

19

19

19

19

18

18

18

18

18

18

18

18

18

18

18

20

20

20

20

20

26

26

27

27

PWFMC-R10-20

PWFMC-R10-26

PWF-R10-20

PWF-R10-26

27

27

27

27

Page 149: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

149

BÖLLHOFF, the specialist in assembly techniques

Whatever the industry, we have the solution to yourfastening needs, including the following sectors:

� automotive - marine - aerospace� electronic - electric - plastic� construction - wood - furniture� machine-tools, rail.

Böllhoff, industrial partner in more than 23 countries

Böllhoff has a worldwide presence, through its productioncentres and subsidiaries and a network of agents anddistributors, an efficient international distribution channel,which specialises in more than 60,000 quality certifiedproducts.

Böllhoff, service and responsiveness

Böllhoff propose a wide range of services whose mainobjective is to optimise processes and to reduce costs.

Böllhoff, quality at all levels

Permanent controls and rigorous organisation allow us tomaintain, ISO 9001, QS 9000 and ISO 14001 certificationsamong many others.

All our factories have quality systems.

Böllhoff, listens to your requests, searching forcontinuous innovation

To facilitate adaptation to rapid changes in productionmethods, Böllhoff designs standard and specific productsand installation equipment adapted to the needs of itscustomers

Page 150: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

150

Notes®

Page 151: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

151

Page 152: Mise en page 1 · 2021. 1. 7. · 3 Contents Page Selectionguide 4 OperationofHUCK ® LockBolts 6 OperationofHUCK ® structuralblindrivets 7 Rangeofstructuralblindrivets-Magna-Lok®

Böllhoff GroupPlease find your local contact on www.boellhoff.com

or contact us under [email protected]

Subject to technical change. Reprinting, even in extract form, only permitted with express consent.Observe protective note according to ISO 16016.

Böllhoff International with companies in:ArgentinaAustriaBrazil

CanadaChina

Czech RepublicFrance

GermanyHungary

IndiaItaly

JapanMexicoPoland

RomaniaRussiaSlovakia

South KoreaSpain

SwitzerlandThailandTurkey

United KingdomUSA

Apart from these 24 countries, Böllhoff supports its international customersin other important industrial markets in close partnership with agents and dealers.