The field of automation issubject to a permanent andinnovative change of productsand applications. The focus ison increasing the productivityand realizing a smooth-run-ning production process witha minimum of human inter-ventions on machinery andsystems. The ideal, a fullyautomated and totally safemachine however will alwaysremain a dream, though therobots used in productionplants already are a big steptowards this goal.
Human intervention andknowledge will always berequired for the commission-ing, monitoring and mainte-nance of modern industrialsystems. Man however is notinfallible and ignorance or lackof information, thoughtless-ness or negligence oftenleads to damages.
For these reasons Europeandirectives such as theMachinery Directive 98/37/EC(2006/42/EG) and their corre-sponding standards wereimplemented at Europeanlevel. These standards aim atdetecting and constructivelyavoiding all possible risks andhazards during the planningand project phase ofmachines and systems.Safety components must beused to minimize or eliminatethe residual risks.
In this way, manufacturersand users are making equiva-lent efforts to set up an opti-mal process flow, which offersthe highest possible protec-tion to the operating staff. Thechallenge for all manufactur-ers of safety components is todesign efficient and safeproduct solutions for mechan-ical engineers. Flaps anddoors are the simplest meansof access to the machine.
These separating hardguard-ing safety solutions offer anefficient and effective protec-tion against hazardous move-ments and products beingejected from the machine.When these safety guards areopened, the machine isbrought to standstill (throughthe corresponding safety sen-sor transmitting the “stop”
A “virtual safety guard“ in theform of an active optoelec-tronic device (AOPD), e.g. asafety light curtain, is a per-fect solution, offering both anoptimal protection of humanlife and uninterrupted produc-tion process.
Introduction – Optoelectronic safety sensors
EN 61496signal to the control), whichinterrupts and therefore slowsdown the production. In caseof continuous processes,which must not be interrupt-ed, solenoid interlocks protectman and the work pieceagainst damages.
Safety fences are not suitablefor production processesrequiring the material to betransported into the workingarea by means of conveyorbelts, as it does not allow foran ergonomic and optimalwork sequence.
Depending on the application,the AOPD are used for point ofoperation, danger zone andperimeter guarding. The usercan choose from a large rangeof different optoelectronic safe-ty solutions e.g. light barriers,light grids, light curtains andlaser scanners.
The safety light barrier sys-tems of the SLB range areactive optoelectronic protec-tive devices (AOPD) fulfillingthe Control Category 2 or 4 inaccordance with EN 954-1 orEN 61496, or PLc or PLe inaccordance with EN ISO13849-1. These systems areused as entry guards on haz-ardous zones, points of oper-ation and entrances. Theyprotect human life withoutrestricting the production flow.
Typical applications for safetylight barriers are on robots,automatic-processing plants,transfer lines, rack storagesand pallet loaders.The entire safety light barriersystem includes a light emit-ter, a light receiver and a safe-ty monitoring module. Thismodule monitors the signalsof the emitter.
If the light beam is interrupt-ed, a signal is emitted to bringthe dangerous movement ofthe machine to standstill. Thesafety monitoring moduleintegrates functions such asstart and restart inhibit as wellas a contactor monitoring.The maintenance-free safetysensors of the system withprotection class IP 67 offer anintegrated soiling check.Because of their small size,safety light barriers can be fit-ted almost everywhere.
Safety light grids /light curtains
The safety light curtains andsafety light grids of the SLCand SLG meet the require-ments of Control Category 2 or4 to EN 954-1 and Type 2 orType 4 to EN 61496, or PLc orPLe in accordance with EN ISO13849-1. They safeguardpoints of operation and haz-ardous areas on different appli-cations, e.g. presses, robotstations, injection moldingmachines, pallet machines, etc.
In these active optoelectronicprotective devices (AOPD),the emitter and receiver arefitted in two separate enclo-sures. An invisible infraredsignal is sent from the emitterand monitored by the receiver.If the light beam is interruptedby an object or a person, astop signal is emitted to bringthe machine to standstill.
The protection field is definedby the height and width of theprotection field. The protectedheight is the range betweenthe first and last infrared lightbeam of a light curtain. Theprotected height defines thephysical size of the system tobe used.
The protected width or oper-ating range is the distancebetween the transmitter andreceiver unit.
For an accurate detection ofobjects with different sizes inthe hazardous area, the usercan choose between lightgrids and light curtains withdifferent resolutions. Here, thefollowing rule applies: thesmaller the distance betweentwo adjacent light beams, themore accurate the detectionsensitivity of the AOPD.For the detection of bodyparts, a distinction is madebetween finger, hand andbody protection.
EN 999 or DIN EN ISO 13857sets the biometric data for fin-ger protection to 14 mm, forhand detection to 30 mm, forleg detection up to 70 mmand for body detection to over70 mm.
Safety light grids with 2, 3or 4 individual beams aregenerally used to detect thepenetration of the entirehuman body. Safety lightcurtains are multiple beamsystems (> 5 individualbeams) and can also detectsmaller objects in case ofintrusion into the protectedfield. The maintenance- freesafety light curtains and lightgrids can be smoothly fittedusing an M12 connector andare equipped a diagnosticinterface and LED indicationfor status messages.
Depending on the type ofsafety light curtain or light gridused, the components offeran integrated monitoringmodule with start/restartinhibit and external devicemonitoring. Additional func-tions such as blanking, mut-ing and cascading of the lightcurtains are available as well.
The SLC and SLG productseries therefore offer amaximum of flexibility forsafeguarding different pointsof operation.
Important conditions forthe use of optoelectronicsafety devices:
In order to choose the appro-priate active optoelectronicprotective device (AOPD) suchas light barriers, light cur-tains/grids and laser scannersand to use them correctly,both the requirements of thestandards (EN 61496, EN 999,EN 294, C standards etc.) andproduct-specific features(detection sensitivity, range,etc.) must be taken intoaccount. AOPD’s can beused, provided that:
• the dangerous movementcan be stopped at all timesand that it is ensured thatthe dangerous area can onlybe reached after the move-ment has come to standstill,
• the dangerous movementcan be stopped at all timesand that it is ensured thatthe dangerous area can onlybe reached after the move-ment has come to standstill,
• the run-out time of themachine and all safety com-ponents is known,
• no objects (work pieces,sparks, liquids, etc.) canbe ejected,
• the AOPD meet the require-ments of Type 2 or Type 4acc. to EN 61496,
• the dangerous area can onlybe reached by passingthrough the protected field ofthe AOPD,
• reaching over, under orthrough the protected field isimpossible,
• the start or restart commanddevices are fitted in such away that the entire hazardousarea is completely visiblefrom the outside and that itcannot be activated fromwithin the hazardous area
• and the safety distance is cal-culated and constructivelyapplied in accordance withEN 999.
The effectiveness of the safetyguard corresponds to the riskassessment, which was carriedout during the planning anddesign phase, taking all impor-tant boundary conditions, e.g.environment, machine andfunction into account.
Safety distanceIf the dangerous area of themachine is accessible fromthe top because of its particu-lar construction, the height Hof the topmost beam of thelight barrier must be at least1800 mm above the base Gof the machine.
Normal approachfor light curtains:(Resolution: from 40 mmup to max. 70 mm)
The minimum safety distanceS is calculated in the followingway:
S = 1600 T + 850
The height of the topmostlight beam must be at least900 mm, the height of thelowermost light beam maxi-mum 300 mm above the bot-tom (for the protection of chil-dren younger than 14: 200mm).
Safety distances for lightcurtains
Between the interruption of alight beam and the standstillof the machine, a certain timeexpires. The safety light gridor light curtain must be sizedand installed such that a stopwould be signaled and thehazard ceased prior to a per-son or a body part accessingthe hazard.
The standard EN 999 providesthe user with detailed infor-mation about the calculationof the minimum safety dis-tances. These include thefollowing important influenc-ing factors:
• run-out time of the entiresystem, taking the differentreaction times of the individ-ual systems into account(e.g. machine, safety moni-toring module, AOPD etc.)
• capacity of the AOPD todetect body parts (fingers,hand and entire humanbody)
• set-up of the safety guard innormal condition (vertical fit-ting), parallel condition (hori-zontal fitting) or at an arbi-trary angle in front of thesafety guard and
• the speed at which the pro-tection field is approached.
For the calculation of the min-imum safety distance S to thehazardous area, EN 999 pres-ents the following general for-mula:
Where:S the safety distance to thedangerous area (mm)
K the approach speed of thebody or the body part(mm/s)
T the entire reaction time ofthe system(s) (including themachine’s run-out time, thereaction time of the safetyguard and the safety moni-toring module etc.)
C additional distance (mm) infront of the safety guard
S = K x T + C
Normal approachfor light curtains:(Resolution: max. 40 mm)
The minimum safety distanceS is calculated in the followingway:
S = 2000 T + 8 (D-14)
(D = Resolution)
This formula applies to safetydistances up to 500 mm. Theminimum safety distanceSmin may not be less than100 mm.
If the calculation produces adistance larger than 500 mmfor S, the calculation can berepeated with a lowerapproach speed:
Normal approachfor light grids:(Resolution: > 70 mm)
The minimum safety distanceS is calculated using thefollowing formula:
S = 1600 T + 850
For safety guards withmultiple beams, height H (mm)above the reference floor ofthe individual beams must beapplied in the following way:
When using light curtains orlight grids, particular attentionmust be paid to the tamperingpossibilities of the safetyguard and to the mechanicalrisks (e.g. crushing, shearing,cutting, ejection).
For the SLC/SLG…M/S prod-uct series, the master lightcurtain can be extended withanother (slave) light curtain(cascading). In this way, multi-ple protection fields can begenerated. A protection fieldis created between the emitterand receiver and between theslave components.
This device cascading pro-vides for a comfortable andefficient protection of contigu-ous protection fields againstreaching over or through theprotection field. The slavelight curtains are connected tothe master by means of anM12 connector.
The master and slave lightcurtains are available indifferent sizes and resolutionsand allow for almost any com-bination.
Muting
If goods or objects must betransported in or out of thehazardous area withoutstopping the machine, thesafety light curtain must beautomatically and temporarilysuspended.
To this end, two or four mutingsensors are used to detectwhether a person is approach-ing the hazardous area or atransport system enters orleaves the hazardous area.Suitable muting sensors arelight barriers, proximity switch-es or position switches.The integrated safety-mutingcontroller of the safety lightcurtain or light grid monitorsand controls the mutingprocess.
The safety outputs are not dis-abled. Any malfunction of themonitored signal source willcause the OSSD’s to beswitched off. Depending onthe application, different lightcurtains with integrated mutingfunction are available. Detailedproduct information can befound in this brochure frompage 33.
Blanking /Floating Blanking
If continuity of the productionprocess is required, a part ofthe protection field can beblanked without triggering astop signal.In this way, objects such aswork pieces can be fed or aconveyor belt can bepositioned at a fixed positionin the protection field.
The integrated floatingblanking function of theSLC…B light curtains enablesa flexible blanking of up to 2adjacent light beams in theprotection field of the lightcurtain. This function isrequired to ensure that one ortwo adjacent light beams canbe interrupted at an undefinedposition in the protection field.
In this way, objects such asfixtures or materials withslightly varying heights can befed through the light curtainwithout triggering a stopsignal. Different blankingfunctions are available. Thedistinguishing feature of thedifferent modes is the numberof light beams that can beinterrupted by an object. In
addition to that, it can bedefined whether the objectmay interrupt the protectionfield permanently or onlytemporarily. The interruptedlight beams can be at anyposition in the protection field.
Except the first infrared lightbeam (the beam closest to theconnector), any light beam canbe used for blanking.
When blanking is applied, theresolution of the light curtainchanges. The technicaldocumentation of the differentlight curtains includes thetables with the effectiveresolutions D to calculate theminimum safety distance toEN 999.
Further technical productinformation can be found inthis brochure.
• PLc and PLe acc. to EN ISO 13849-1• Control Category 2 and 4 acc. to EN 954-1or acc. to EN 61496, Type 2 and Type 4
• Up to 4 pairs of one-way light barriers canbe connected
• Different functions:Start/Restart interlockContactor monitoringCyclic testing
• Integrated soiling check• Status and error indication• Signalling outputs for external indications• Free of maintenance• Extremely compact design• Simple and flexible mounting and adjustment
• Up to two pairs of light barrier devices canbe connected
• Co-ordinated for use with SLB 200 R/Esafety light barriers
• 1 safety contact, STOP 0• 1 signalling output• Operating voltage 24 VDC• Test input• LED display of switching conditions• Response time ≤ 30 ms• Start/Restart interlock can be switchedactive or inactive
• Contactor monitoring can be switchedactive or inactive
• Additional cyclic testing
Approvals
Ordering detailsSLB 200-C04-1R
Technical dataStandards: IEC/EN 61496-1/-2, IEC 60947-5-3, IEC 61508Start conditions: Test button, start-resetbutton, on/off codingFeedback circuit (Y/N): yesMax. switching frequency: 10 HzRated operating voltage Ue: 24 VDC ± 20%Rated operating current Ie: 180 mAOutputs:Stop category 0: 1Stop category 1: 0Number of safety contacts: 1Number of auxiliary contacts: 0Number of signalling outputs: 1Max. switching capacity of the safety contacts: 8 ASwitching capacity of the signalling outputs: 500 mAMax. fuse rating of the safety contacts: 4 A gG D-fuseUtilisation category to EN 60947-5-1: AC-15: 250 V / 2 A
DC-13: 24 V / 2 AAmbient conditions:Environmental temperature: 0°C…+50°CStorage and transport temperature: -20°C…+80°CProtection class: Enclosure: IP 40, Terminals: IP 20, Clearance: IP 54Mounting: Snaps onto standard DIN rail to EN 60715Connection type: Screw connectionmax. cable section: 4.0 mm2 (incl. conductor ferrules)Dimensions (Height/Width/Depth): 84 x 45 x 118 mmSafety Classifications:Performance Level (EN ISO 13849-1): up to cControl Category (EN954-1): up to 2
Note• Monitoring two pairs of light barrier devicesand the power contactor using theSLB 200-C safety monitoring module
• Test push buttonIThe test push button is connected to X13and X14 in order to carry out a check ofthe light barrier monitoring function. Theterminals X15 and X16 must be bridged.
• Contactor checkTo monitor an externalcontactor, the feedback circuit is connectedto X17 and X18. The terminals X19 and X20must be bridged.
• Start push buttonHThe start push button can be used to startthe monitoring of the light barriers for a newstart or after an interruption. The terminalsX3 and X4 must be bridged.
• It is also possible to connect only one pair oflight barrier devices.
NoteIn order to set for the desired mode ofoperation and number of light barriersconnected, remove the front cover of thesafety monitoring module. As supplied allswitches are in Position 1.
Wiring diagram
X21
L1
A1 X2
SLB-R
1 1 2 2
SLB-RSLB-E SLB-E
K1
X1 X6 X7 X8
X13 X14 X15 X16 X17 X18 X19 X20A2
3
X3 X4 X5 X10X9
NM
X11 X12 13
X22 Y1 X23 14
BN
BN
BN
BN
WH
BK
WH
BK
+24 VDC
0 V
SLB 200-C
K3
K4
max.
NoteThe required functions can be selected by means of the internal DIP switches.
DIP switch 1 DIP switch 2 DIP switch 3
Position 1 With contactor check With start/restart interlock Connection of twolight barriers
Position 2 Without contactor check Without start/restart interlock Connection of onelight barrier
The wiring diagram is shown for the de-energized condition.
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
• Up to 4 light barrier pairs SLB 400can be connected
• Co-ordinated for use with SLB 400 R/Esafety light barriers
• 2 safety contacts, STOP 0• 2 signalling outputs• Cross-wire monitoring• ISD Integral System Diagnostics• Operating voltage 24 VDC• Feedback circuit to monitor externalcontactors
• Two short-circuit proof additionaltransistor outputs
• Response time ≤ 30 ms• Start/Restart interlock can be switchedactive or inactive
• Contactor monitoring can be switchedactive or inactive
• Can be coded
Approvals
H
Ordering detailsSLB 400-C10-1R
Technical dataStandards IEC/EN 61496-1/-2, IEC 60947-5-3, IEC 61508Start conditions: Start-reset button, on/off codingFeedback circuit (Y/N): yesMax. switching frequency: 10 HzRated operating voltage Ue: 24 VDC ± 15%Rated operating current Ie: 0.3 A without additional transistor
outputs and safety light barriersMax. fuse rating of the operating voltage: 1 AOutputs:Stop category 0: 2Stop category 1: 0Number of safety contacts: 2Number of auxiliary contacts: 2Number of signalling outputs: 2Max. switching capacity of the safety contacts: 2 ASwitching capacity of the auxiliary contacts: 2 ASwitching capacity of the signalling outputs: 100 mAMax. fuse rating of the safety contacts: 2 A gG D-fuseUtilisation category to EN 60947-5-1: AC-15: 250 V / 2 A
DC-13: 24 V / 2 ALED display: ISDAmbient conditions:Environmental temperature: 0°C…+55°CStorage and transport temperature: -25°C…+70°CProtection class: Enclosure: IP 40, Terminals: IP 20, Clearance: IP 54Mounting: Snaps onto standard DIN rail to EN 60715Connection type: Screw connectionmax. cable section: 4.0 mm2 (incl. conductor ferrules)Dimensions (Height/Width/Depth): 75 x 99.7 x 110 mmSafety Classifications:Performance Level (EN ISO 13849-1): up to eControl Category (EN954-1): up to 4
Note• Monitoring up to four pairs of light barrierdevices and the power contactors using theSLB 400-C safety monitoring module
• Connection of two pairs of safety lightbarrier devices:When two pairs of safety light barriers areconnected, the terminals X9-X10 andX11-X12 must be bridged.
• Restart push buttonJThe restart function can be selected bymeans of the DIP switches. When a startpush button is connected to X5 and X6, itmust be operated for min. 250 ms and max.5 s after an interruption of the safety lightbarriers.
NoteThe following faults are registeredby the safety monitoring modulesand indicated by ISD• Short-circuit on the connecting leads• Interruption of the connecting leads• Failure of the safety relay to pull-inor drop-out
• Fault on the input circuits or the relay controlcircuits of the safety monitoring module
• Mutual influence between the connectedpairs of light barrier device and others onneighboring systems
Wiring diagram
8
Note
L1
K4
K5
3
+24 VDC
0 V 0 V
NM
X2X1A1
1 2 3 4
1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
1 2 3 4 1 2 3 4 1 2 3 4
X3 X4 X7X5 X6 X8 13 23 33 41
A2
0V
SLB-E
SLB-E SLB-E
SLB-R
SLB-R SLB-R
SLB-RSLB-E
T3 Q3 T4 Q4 PM INDIC.
U OUT
U OUT
B
B
Y1 Y2 -
-
+
+
X9 X10 X11 X12 X13 X14 14 24 34 42
24V T0 T2Q1 Q2 RESTART CONT.M
Made in Germany
RESTART RELAY
R
The ISD tables (Integral System Diagnostics) for analysis of the fault indications and their causesare shown in the manual.
The wiring diagram is shown for the de-energized condition.
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of asuitable circuit.
• Safety light curtain• Control category Type 2 to IEC/EN 61496-1, -2• Resolution 30 and 80 mm• Protection field heights from175 mm to 1675 mm• Integrated start/restart interlock• Integrated contactor control†
• Integrated blanking function†
• Diagnostic and parametrization interface†
• Range 0.3 m ... 14 m• Integrated self-test• Fail-safe transistor outputs• Status display• Protection class IP 65• Signalling output
Legend:A: Total lengthProtection field height 175 mm: A = 216 mmProtection field height 250 ... 1675 mm:A = 28.5 mm + Protection field height
Technical dataStandards: IEC/EN 61496-1/-2
Type 2Enclosure: AluminiumEnclosure dimensions: ø 40 mmConnection: Connector plug
M12, 8-poleMax. cable length: 100 m / 1ΩProtection class: IP 65 to EN 60529Response time: 9 … 45 ms
(depends on lengthand resolution)
Detection sensitivity(Resolution): 30 and 80 mmProtection field height:Resolution 30 mm 175 ... 1675 mmResolution 80 mm 325 ... 1675 mm2-, 3-, 4-beam 500, 800, 900 mmProtection field width,Range: 0.3 ... 6 m (Standard),SLC 4 ... 14 m (High range)SLG 5 ... 30 m (High range)Start/restart interlock: IntegratedContactor control: IntegratedBlanking function: IntegratedLight emission wavelength: 880 nm (infrared)Ue: 24 VDC ± 10%Safety outputs: 2 x PNP, 200 mASignalling output: PNP 100 mAPower consumption: Emitter 4 W,
Receiver 8 WData interface: RS 485Status and diagnostics: LED displayAmbient temperature: –10 °C … + 50 ºCStorage andtransport temperature: – 20 °C … + 70 ºCClassification:to IEC/EN 61508: SIL 2to EN ISO 13849-1: PL d
PFH-value: 3.59 x 10-8 / hto EN 954-1: Control Cat. 2
Ordering detailsConnector:Connector plug M12, 8-pole straightfor emitter/receiverCable length 5 m KA-0904Cable length 10 m KA-0905Cable length 20 m KA-0908
Notes† Curtains are delivered with the EDM turnedoff — NSR 0700 required for programmingthese functions
SLG 220 standard
A
¤ 40
• Safety light grid• 2-, 3- or 4-beam light grid• Range 0.3 ... 30 m
Legend:A: Total lengthA = 78.5 mm + Distance between
Type 2Enclosure: AluminiumEnclosure dimensions: ø 40 mmConnection: Connector plugMaster Emitter: M12, 8-pole,Master Receiver: M12, 8-poleSlave Emitter: M12, 6-pole,Slave Receiver: M12, 6-poleMax. cable length: 100 m / 1ΩMax. cable length: (Master/Slave) 0.3 mProtection class: IP 65 to EN 60529Response time: 12 … 65 ms
(depends on lengthand resolution)
Detection sensitivity(Resolution): 30 and 80 mmProtection field height:Resolution 30 mm 175 ... 2450 mmResolution 80 mm 325 ... 2450 mmProtection field width, Range: 0.3 ... 6 mStart/restart interlock: IntegratedContactor control: IntegratedCascading: (Master/Slave) possibleLight emission wavelength: 880 nm (infrared)Ue: 24 VDC ± 10%Safety outputs: 2 x PNP, 200 mASignalling output: PNP, 100 mAPower consumption: Emitter 4 W,
Receiver 8 WData interface: RS 485Status and diagnostics: LED displayAmbient temperature: –10 °C … + 50 ºCStorage andtransport temperature: – 20 °C … + 70 ºCClassification:to IEC/EN 61508: SIL 2to EN ISO 13849-1: PL d
PFH-value: 3.59 x 10-8 / hto EN 954-1: Control Cat. 2
Different lengths and resolutions can becombined for Master/Slave.
Approvals
Ordering detailsConnector:Connector plug M12, 8-pole straightfor emitter/receiverCable length 5 m KA-0904Cable length 10 m KA-0905Cable length 20 m KA-0908
for Master/Slave connectionFemale connector 2 x M12, 6-pole straightCable length 0.3 m KA-0907
Mounting brackets are included in the delivery.
Notes* only for resolution 30 mm** only protected heights from325 mm to 775 mm
Notes† Curtains are delivered with the EDMturned off — NSR 0700 required forprogramming these functions
• Safety light curtain• Control category Type 2 to IEC/EN 61496-1, -2• Resolution 30 and 80 mm• Protection field height:Master from 175 mm to 1675 mmSlave from 325 mm to 775 mm
• Cascading of Master and Slave devices• Range 0.3 m ... 6 m• Fail-safe transistor outputs• Status display• Protection class IP 65• Signalling output• Integrated self-test
Legend:A: Total lengthProtection field height 175 mm: A = 216 mmProtection field height 250 ... 1675 mm:A = 28.5 mm + Protection field height
• Safety light curtain• Control category Type 2to IEC/EN 61496-1, -2
• Resolution 30 and 80 mm• Protection field heights from175 mm to 1675 mm
• Protection class IP 69K• Integrated start/restart interlock• Integrated contactor control†
• Integrated blanking function• Diagnostic and parametrization interface†
• Range 0.3 m ... 14 m• Integrated self-test• Fail-safe transistor outputs• Status display• Signalling output
Legend:A: Total lengthA = 54 mm + Protection field height
SLG 220 IP 69K
A
¤ 60
• Safety light grid• 2-, 3- or 4-beam light grid• Range 0.3 ... 30 m
Legend:A: Total lengthA = 104 mm + Distance between
outermost beams
Technical dataStandards: IEC/EN 61496-1/-2
Type 2Enclosure: AluminiumEnclosure dimensions: ø 60 mmConnection: Cable 8-pole
with connector M12, 8-pole5 m long
Max. cable length: 100 m / 1ΩProtection class: IP 69KResponse time: 9 … 45 ms
(depends on lengthand resolution)
Detection sensitivity(Resolution): 30 and 80 mmProtection field height:Resolution 30 mm 175 ... 1675 mmResolution 80 mm 325 ... 1675 mm2-, 3-, 4-beam 500, 800, 900 mmProtection field width,Range: 0.3 ... 6 m (Standard),SLC 4 ... 14 m (High range)SLG 5 ... 30 m (High range)Start/restart interlock: IntegratedContactor control: IntegratedBlanking function: IntegratedLight emission wavelength: 880 nm (infrared)Ue: 24 VDC ± 10%Safety outputs: 2 x PNP, 200 mASignalling output: PNP, 100 mAPower consumption: Emitter 4 W,
Receiver 8 WData interface: RS 485Status and diagnostics: LED displayAmbient temperature: –10 °C … + 50 ºCStorage andtransport temperature: – 20 °C … + 70 ºCClassification:to IEC/EN 61508: SIL 2to EN ISO 13849-1: PL d
PFH-value: 3.59 x 10-8 / hto EN 954-1: Control Cat. 2
outermost beams:0500-02 500 mm, 2-beam0800-03 800 mm, 3-beam0900-04 900 mm, 4-beam
Range 0.3 m … 6 mH High Range 5 m … 30 m
Approvals
Mounting brackets (stainless steel) are included in the delivery.Notes†Curtains are delivered with the EDM turned off — NSR 0700required for programming these functions
Type 4Enclosure: AluminiumEnclosure dimensions: ø 49 mmConnection: Connector plugEmitter: M12, 4-pole,Receiver: M12, 8-poleMax. cable length: 100 m / 1 ΩProtection class: IP 67 to EN 60529Response time: 10 … 27 ms
(depends on length and resolution)Detection sensitivity(Resolution): 14, 30 and 50 mmProtection field height:Resolution 14 mm 170 ... 1450 mmResolution 30, 50 mm 170 ... 1770 mm2-, 3-, 4-beam 500, 800, 900 mmProtection field width, Range:Resolution 14 mm 0.3 m ... 7 mResolution 30, 50 mm 0.3 m ... 10 mHigh RangeResolution 30 mm 0.3 m ... 18 m2-, 3-, 4-beam 0.3 m ... 10 mHigh Range2-, 3-, 4-beam 8 m ... 40 mStart/restart interlock: IntegratedContactor control: IntegratedBlanking function: IntegratedCascading: (Master/Slave) –Light emission wavelength: 880 nm (infrared)Ue: 24 VDC ± 10%Safety outputs: 2 x PNP, 500 mAPower consumption: Emitter 4 W,
Receiver 8 WData interface: RS 485Status and diagnostics: LED displayAmbient temperature: –10 °C … + 50 ºCStorage andtransport temperature: – 20 °C … + 70 ºCClassification:to IEC 62061: SIL 3to EN ISO 13849-1: PL e
PFH-value: 7.42 x 10-9 / hto EN 954-1: Control Cat. 4
SLC 420 standardA
¤ 49
• Safety light curtain• Control category Type 4to IEC/EN 61496-1, -2
• Resolution 14, 30 and 50 mm• Protection field heights from170 mm to 1770 mm
14 Resolution 14 mm30 Resolution 30 mm50 Resolution 50 mm
Range 0.3 m … 7 m**Range 0.3 m … 10 m*
H High Range 0.3 m … 18 m* M Master function
S*** Slave function
Approvals
Safety light curtains and safety light grids
Technical dataStandards: IEC/EN 61496-1/-2
Type 4Enclosure: AluminiumEnclosure dimensions: ø 49 mmConnection: Connector plugMaster Emitter: M12, 4-pole,Master Receiver: M12, 8-poleSlave Emitter: M12, 4-pole,Slave Receiver: M12 1, 8-poleMax. cable length: 100 m / 1 ΩMax. cable length: (Master/Slave) 0.8 mProtection class: IP 67 to EN 60529Response time: 10 … 37 ms
(Depends on length and resolution)Detection sensitivity(Resolution): 14, 30 and 50 mmProtection field height:Resolution 14 mm 170 ... 2100 mmResolution 30, 50 mm 170 ... 2420 mmProtection field width, Range:Resolution 14 mm 0.3 m ... 7 mResolution 30, 50 mm 0.3 m ... 10 mHigh Range 0.3 m ... 18 mStart/restart interlock: IntegratedContactor control: IntegratedBlanking function: IntegratedCascading: (Master/Slave) possibleLight emission wavelength: 880 nm (infrared)Ue: 24 VDC ± 10%Safety outputs: 2 x PNP, 500 mAPower consumption: Emitter 4 W,
Receiver 8 WData interface: RS 485Status and diagnostics: LED displayAmbient temperature: –10 °C … + 50 ºCStorage andtransport temperature: – 20 °C … + 70 ºCClassification:to IEC 62061: SIL 3to EN ISO 13849-1: PL e
PFH-value: 7.42 x 10-9 / hto EN 954-1: Control Cat. 4
SLC 420 Master / Slave
A
¤ 49
• Safety light curtain• Control category Type 4 to IEC/EN 61496-1, -2• Resolution 14, 30 and 50 mm• Protection field height:Master from 170 mm to 1770 mmSlave from 170 mm to 650 mm
• Cascading of Master and Slave devices• Range 0.3 m ... 7 m or 0.3 m ... 10 m• Fail-safe transistor outputs• Optical synchronisation• Status display
Legend:A: Total lengthA = 84.5 mm + Protection field height
Ordering detailsConnector:Connector plug for emitterM12, 4-pole straightCable length 5 m KA-0804Cable length 10 m KA-0805Cable length 20 m KA-0808Connector plug for receiverM12, 8-pole straightCable length 5 m KA-0904Cable length 10 m KA-0905Cable length 20 m KA-0908Connector plug for Master/Slave connectionEmitterFemale connector 2 x M12, 4-pole straightCable length 0.8 m KA-0810ReceiverFemale connector 2 x M12, 8-pole straightCable length 0.8 m KA-0901
Ordering detailsMounting brackets are included in the delivery.
Notes* only for resolution 30 mm** only for resolution 30 and 50 mm***Protection field heights from 170 ... 650 mm
†Curtains are delivered with the EDM turnedoff — NSR 0700 required for programmingthese functions
• Safety light curtain• Control category Type 4to IEC/EN 61496-1, -2
• Resolution 14 mm and 30 mm• Protection field heights from170 mm to 1450 mm
• Protection class IP 69K• Integrated start/restart interlock• Integrated contactor control†
• Integrated blanking function (fixed andmobile blanking)†
• Diagnostic and parametrization interface†
• Range 0.3 m ... 10 m• Fail-safe transistor outputs• Optical synchronisation• Status display
Legend:A: Total lengthA = 97 mm + Protection field height
Technical dataStandards: IEC/EN 61496-1/-2
Type 4Enclosure: AluminiumEnclosure dimensions: ø 60 mmConnection:Emitter/Receiver: Cable gland PG 9,Receiver Cable length 5 m, 8-poleEmitter Cable length 5 m, 4-pole
Gore TM Membrane M12Max. cable length: 100 m / 1 ΩProtection class: IP 69 to EN 60529Response time: 10 … 27 ms
(depends on lengthand resolution)
Detection sensitivity(Resolution): 14, 30 mmProtection field height:Resolution 14, 30 mm 170 ... 1770 mm2-, 3-, 4-beam 500, 800, 900 mmProtection field width, Range:Resolution 14 mm 0.3 m ... 7 mResolution 30 mm 0.3 m ... 10 m2-, 3-, 4-beam 0.3 m ... 10 mStart/restart interlock: IntegratedContactor control: IntegratedBlanking function: IntegratedCascading: (Master/Slave) –Light emission wavelength: 880 nm (infrared)Ue: 24 VDC ± 10%Safety outputs: 2 x PNP, 500 mAPower consumption: Emitter 4 W,
Receiver 8 WData interface: RS 485Status and diagnostics: LED displayAmbient temperature: –10 °C … + 50 ºCStorage andtransport temperature: – 20 °C … + 70 ºCClassification:to IEC 62061: SIL 3to EN ISO 13849-1: PL e
PFH-value: 7.42 x 10-9 / hto EN 954-1: Control Cat. 4
SLG 420 IP 69K
A
¤ 60
• Safety light grid• 2-, 3- or 4-beam light grid• Range 0.3 ... 12 m
Legend:A: Total length2-beam A = 747 mm3 and 4-beam A = 1067 mm
Miniaturized safety light grids and safety light curtains
Technical dataStandards: IEC/EN 61496-1/-2Control Category: Type 4
in combination withevaluation unit NSR-0605
Enclosure: AluminiumEnclosure dimensions: 12 x 20 mmConnection: Connector M8, 4-poleMax. cable length: 100 m / 1 ΩProtection class: IP 65 to EN 60529Response time includingrelay output: 50 msDetection sensitivity (Resolution): 30 mmProtection field height: 236 ... 1804 mmProtection field width, Range: 0.3 m ... 3.5 mStart/restart interlock: IntegratedContactor control: IntegratedLight emission wavelength: 880 nm (infrared)Ue: 22 ... 30 VDC
18 ... 25 VACPower consumption: 8 W
SystemData interface: RS 485Status and diagnostics: LED displayAmbient temperature: 0° C … + 50º CStorage andtransport temperature: – 10° C … + 70º CSafety outputs:2 x Relay contact 250 V / 4 ASignalling output:1 x Relay contact 42 V / 4 AClassification:to IEC 62061: SIL 3to EN ISO 13849-1: PL e
PFH-value: 1.26 x 10-8 / hto EN 954-1: Control Cat. 4
SLC 430
• Safety light curtain• Control category Type 4to IEC/EN 61496-1, -2
• Resolution 30 mm• Protection field heights from236 mm to 1804 mm
• Slim design, size 12 x 20 mm• Integrated start/restart interlock• Integrated contactor control• Range 0.3 m ... 3.5 m• Status display• Protection class IP 65
NSR-0605
• Safety Controller• Enclosure dimensions: 240 x 160 mm
Ordering detailsConnector:Connector plug for emitter / receiverM8, 4-pole straightCable length 5 m KA-0610Cable length 10 m KA-0611
Included in deliveryEmitter and receiver including mounting set,controller NSR-0605, cable set KA-0610(cable length 5 m)
• PLe acc. to EN ISO 13849-1• Control Category 4 acc. to EN 954-1or acc. to IEC 61496, Type 4• Integrated muting function• 2 plugs for muting sensors• Integrated override function• Integrated cyclic operation function• Diagnostics display• Optical synchronisation• Compact design• Simple, flexible mounting and adjustment
Safety light curtains with integrated muting-, blanking- and Cyclic-function
The SLC/SLG 415I is a sys-tem for universal use withintegrated muting function.The M8 connectors allow adirect connection and flexiblepositioning of the differentmuting sensors (e.g. induc-tive, capacitive or optical sen-sors). In this way, a safe trig-gering of the muting functioncan be obtained for objects ofdifferent sizes. The additionalintegrated override functionallows for a controlled restartof the machine to transportthe accumulated material outof the protection field after afailure. The safety light cur-tains/grids with muting func-tion enable a smooth andtrouble-free material feeding(input and output), whilstoffering a permanent protec-tion of human life.
• Integrated muting functionfor material transport in1 or 2 directions
• Connection of 2 or 4external muting sensors
• Connection of differentmuting sensors
• Direct connection (M8) ofthe muting sensors to theSLC/SLG
• Muting controller for cross-wise or parallel arrangementof the external sensors
• Adjustable muting time of30 s, 90 min or 100 h
• Integrated override function• Range up to 12 m
Cyclic operation
Cyclic operation is a modeof operation, in which themachine automatically starts awork process, as soon as theoperator releases the protec-tion zone of the light curtain.A cycle is defined as the one-time interruption and releaseof the protection zone.In one-cycle operation, a newmachine cycle is initiated,when the protection zone isinterrupted one time.
Example:The material is fed automati-cally without interruption ofthe protection zone. After ini-tialization, the machine startsthe first cycle. The operatornow interrupts the protectionzone to remove the material.The next cycle starts auto-matically.
In two-cycle operation, a newmachine cycle is started whenthe protection zone is inter-rupted twice.
Example:The operator loads themachine and gives the startcommand. After the processis finished, the operatorremoves the processed mate-rial (1st cycle) and loads anew part for processing (2ndcycle). The next cycle startsautomatically.
The light curtain additionallymonitors a signal (machinecontact) of the machine,which signals the end of thehazardous movement. Thissignal is used for the cyclereset and enables an immedi-ate intervention in the protec-tion zone.
Safety light curtains with integrated muting-, blanking- and Cyclic-function
Receiver 8 WData interface: RS 485Status and diagnostics: LED displayAmbient temperature: –10° C … + 50º CStorage andtransport temperature: – 20° C … + 70º CClassification:to IEC 62061: SIL 3to EN ISO 13849-1: PL e
PFH-value: 7.42 x 10-9 / hto EN 954-1: Control Cat. 4
SLC 425I
A
• Safety light curtain• Control category Type 4 to IEC/EN 61496-1, -2• Resolution 14 and 30 mm• Protection field heights from 170 mm to 1770 mm• Integrated start/restart interlock• Integrated contactor control†
• Integrated muting and override function†
• Integrated blanking function (fixed andmobile blanking)†
• Cyclic operation (1 ... 8 Cycles)†
• Range 0.3 ... 10 m• Fail-safe transistor outputs• Optical synchronisation• Status display• Different muting sequences can be programmed• Protection class IP 67Legend:A: Total lengthEmitterA = 84.5 mm + Protection field heightReceiverA = 148.5 mm + Protection field height
SLG 425I
A
• Safety light grid• 2-, 3- or 4-beam light grid• Protection field heights 500, 800 or 900 mm• Range 0.3 ... 18 m
Legend:A: Total lengthEmitter 2-beam A = 804 mm
3 and 4-beam A = 1124 mmReceiver 2-beam A = 868 mm
Note:Mounting angles, reflectors, and cables are notincluded in the delivery.
Reflection light sensor (Muting sensor)
LF 50-11P
46
44
16
4
4
17
4,3
4,3
13,5
63,5
44
40
50
M 12x1
• Range 5.5 m• Connector can be rotated• LED status display• Protection class IP 67• Antivalent switching outputs• Infrared light 670 nm• Laser protection class 1
Approvals
Ordering detailsLF 50-11P
Technical dataStandards: EN 60974-5-2Laser protection class 1: EN 60825-1-10/03Enclosure: ABSEnclosure dimensions: 50 x 50 x 17 mmConnection: Connector plug
Safety light curtains and safety light grids – accessories
System components
Ordering detailsMounting kit for central fixationfor SLC /SLG 2202 x angle MS-1010Mounting kit for ULS-A42 x incl. screws MS-1031MS-1036 Mounting kitfor SLC/SLG 420-425 in V2A4 x incl. screws MS-1036Mounting kit lateral fixationfor SLC/SLG 420-425Consisting of 2 steel angles,4 screws and 4 T-slot nuts MS-1051
System components
Ordering detailsMounting kit for deflecting mirror ULS-M2 x mounting angle MS-1073
Mounting kit for SLC 4302 x clamping profile MS-690Vibration damper8 x vibration damperfor SLC/SLG 220 MSD-28 x vibration damperfor SLC/SLG 420-425 MSD-4Test rod for resolution 30mm PLS-01Test rod for resolution 14mm PLS-02
System components
Ordering detailsLaser alignment toolfor SLC / SLG Series EA5Muting lamp with LED block MK2Operating conditions indicationred, green, yellow LED MK3Operating conditions indicationred, green MK4Signalling lamp with bulb 24 Vyellow with wall mounting bracket MK5Mounting kit for SLC /SLG 2204 x angle incl. screws MS-10002 x angle incl. screws MS 1072
Safety light curtains and safety light grids – accessories
System components System componentsSystem components
NSR-0801
Deflecting mirror ULS-MLC
NSR-0700
Deflecting mirror ULS-A4, ø 49 mm
Mounting Stands
Muting Carrier Set
Protective enclosure with deflecting mirror
Protective enclosure for light grids
Aluminium profile for SLC 430
Ordering detailsDeflecting mirror ULS-A4 incl. mounting angleMirror height 200 mm ULS-A4-0200Mirror height 400 mm ULS-A4-0400Mirror height 550 mm ULS-A4-0550Mirror height 700 mm ULS-A4-0700Mirror height 850 mm ULS-A4-0850Mirror height 1000 mm ULS-A4-1000Mounting StandsHeight including plinth 500mm MST-0500Height including plinth 750mm MST-0750Height including plinth 1000mm MST-1000Height including plinth 1250mm MST-1250Height including plinth 1500mm MST-1500Height including plinth 1750mm MST-1750Height including plinth 2000mm MST-2000Muting Carrier Set2 x aluminium profile MT-0400
Ordering detailsProtective enclosure with deflecting mirrorversion for 2-beam light grids ULS-ST2version for 3-beam light grids ULS-ST3version for 4-beam light grids ULS-ST4Protective enclosure for light gridsHeight 1114mm hot-dip galvanised SG1Height 1334 mm hot-dip galvanised SG2Height 1114 mm RAL 1021 SG3Height 1334 mm RAL 1021 SG4Aluminium profile for SLC 4302 x profile, length 420 mm MS-15012 x profile, length 643 mm MS-15022 x profile, length 865 mm MS-15032 x profile, length 1090 mm MS-15042 x profile, length 1312 mm MS-15052 x profile, length 1537 mm MS-15062 x profile, length 1761 mm MS-15072 x profile, length 1985 mm MS-1508
Deflection Mirror Application NotesULS-MLC: Should be used when range isgreater than 6 m. With 1 mirror the range isreduced by 10%, with 2 or more mirrors therange is reduced by 15% per mirror.
Deflection Mirror Application NotesULS-4A: Should be used when range is lessthan 6 m. The range is reduced by 20%, witheach mirror; only 1 mirror is recommended percurtain/grid
Besides the traditional safety relay controls, Schmersaloffers CE-type tested safety controls or other safety-oriented bus systems (e.g. AS-i Safety at Work) fordifferent levels of complexity and combination depths,which provide the user with many visualization anddiagnostic possibilities.
Safety monitoring modules for optoelectronic safety components
• Suitable for signal processing of potential-free outputs, e.g. emergency stopcommand devices, position switchesand solenoid interlocks
• Suitable for signal processing from theoutputs of magnetic safety switches (tothis end, equipped with built-in currentand voltage limitation)
• Suitable for signal processing of outputsconnected to potentials (AOPD’s), e.g.safety light grids/curtains
• 1 or 2 channel control• 3 safety contacts, STOP 0• 1 signalling output (NC)• Manual reset without edge detection• Automatic reset function• 4 LEDs to show operating conditions
Approvals
H
Ordering detailsSRB 301LC/B-24V
Technical dataStandards: IEC/EN 60204-1, IEC/EN 60947-5-1, EN 954-1, BG-GS-ET-20Start conditions: Automatic or start buttonFeedback circuit (Y/N): yesON delay with reset button: ≤ 20 msDrop-out delay in case of emergency stop: ≤ 25 msDrop-out delay in case of power failure: ≤ 50 msRated operating voltage Ue: 24 VDC –15%/+20%, residual ripple max. 10%;
24 VAC –15%/+10%Rated operating current Ie: 0.08 AFrequency range: 50 / 60 HzFuse rating for the operating voltage: 0.5 A gG D fuseInternal electronic protection (Y/N): noPower consumption: 2.1 W; 3.0 VAMonitored inputs:Short-circuit recognition: noWire breakage detection: yesEarth connection detection: yes
Number of NC contacts: 2Number of NO contacts: 0Max. conduction resistance: 40 ΩOutputs:Stop category 0: 3Stop category 1: 0Number of safety contacts: 3Number of signalling outputs: 1Max. switching capacity of the safety contacts: 250 VAC, 6 A ohmic (inductive in
case of appropriate protective wiring)Utilisation category to EN 60947-5-1: AC-15: 230 V / 6 A; DC-13: 24 V / 6 AMechanical life: 107 operationsAmbient conditions:Environmental temperature: – 25°C … + 45°CStorage and transport temperature: – 25°C … + 70°CProtection class: Enclosure: IP 40, Terminals: IP 20, Clearance: IP 54Mounting: Snaps onto standard DIN rail to EN 60715Connection type: Screw connection, solid strand or
Weight: 230 gDimensions (Height/Width/Depth): 100 x 22.5 x 121 mmClassification:Standards: EN ISO 13849-1; IEC 61508; IEC 60947-5-3PL: up to eCategory: up to 4PFH value: 5.0 x 10-9 /h for max. 36,500 switching cycles/year and max. 60% contact loadSIL: up to 3Mission time: 20 years
NoteFor some applications, the use of a monitored start button (reset with edge detection) is required.
Safety monitoring modules for optoelectronic safety components
Note• Input level: The example shows a2-channel control circuit with a safety lightgrid, an external reset buttonJ and afeedback circuitS.
• The control system recognizes wire-breakage and earth faults in themonitoring circuit.
• Relay outputs: Suitable for 2 channelcontrol, for increase in capacity or numberof contacts by means of contactors orrelays with positive-guided contacts.
• Connect potential p-type outputs ofsafety light grids/curtains to S12/S22.The devices must have the same referencepotential.
• Automatic start: The automatic start isprogrammed by connecting the feedbackcircuit to the terminals X1/X2. If thefeedback circuit is not required, establisha bridge
LEDThe integrated LED’s indicate the followingoperating conditions:• Position relay K1• Position relay K2• Supply voltage UB
• Internal operating voltage Ui
Wiring diagram
A2
A1 S12 S11 S21 S22 X1 X2 13
L1
33 4123
K2K1
Ui
K2
K1
F1
Ansteuerlogik/Logic
14 24 34 42
N
S
J
KA
KB
KA
KB
KB
KA
NoteThe wiring diagram is shown for the de-energized condition.
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means ofa suitable circuit.
• Suitable for signal processing ofpotentialfree outputs, e.g. emergencystop command devices, position switchesand solenoid interlocks
• Suitable for signal processing of outputsconnected to potentials (AOPDs), e.g.safety light grids/curtains
• 1 or 2 channel control• 3 safety contacts, STOP 0• 1 signalling output (NC)• Optionally with short-circuit recognition(through switch)
• With hybrid fuse• Reset with edge detection or automaticreset function
• 4 LEDs to show operating conditions• Plug-in screw connection
Approvals
H
Ordering detailsSRB 301ST
Technical dataStandards: IEC/EN 60204-1, IEC/EN 60947-5-1, IEC 61508, IEC 60947-5-3, BG-GS-ET-20Start conditions: Automatic or start buttonFeedback circuit (Y/N): yesON delay with automatic start: ≤ 300 msON delay with reset button: ≤ 30 msDrop-out delay in case of power failure: ≤ 50 msRated operating voltage Ue: 24 VDC –15%/+20%, residual ripple max. 10%;
24 VAC –15%/+10%Rated operating current Ie: 0.08 AFrequency range: 50 / 60 HzFuse rating for the operating voltage: 0.5 A gG D-fuseInternal electronic protection (Y/N): noPower consumption: 2.1 W; 3.0 VAMonitored inputs:Short-circuit recognition: noWire breakage detection: yesEarth connection detection: yes
Number of NC contacts: 2Number of NO contacts: 0Max. conduction resistance: 40 ΩOutputs:Stop category 0: 3Stop category 1: 0Number of safety contacts: 3Number of signalling outputs: 1Max. switching capacity of the safety contacts: 250 VAC, 6 A ohmic (inductive incase of
appropriate protective wiring)Utilisation category to EN 60947-5-1: AC-15: 230 V / 6 A; DC-13: 24 V / 6 AMechanical life: 107 operationsAmbient conditions:Environmental temperature: – 25°C … + 45°CStorage and transport temperature: – 25°C … + 70°CProtection class: Enclosure: IP 40, Terminals: IP 20, Clearance: IP 54Mounting: Snaps onto standard DIN rail to EN 60715Connection type: Screw connection, solid strand or multi-strand (incl. conductor ferrules)min. cable section: 0.25 mm2
max. cable section: 2.5 mm2
Weight: 230 gDimensions (Height/Width/Depth): 100 x 22.5 x 121 mmClassification:Standards: EN ISO 13849-1; IEC 61508PL: up to eCategory: up to 4PFH value: 5,0 x 10-9 /h for max. 36,500 switching cycles/year and max. 60% contact loadSIL: up to 3Mission time: 20 years
Safety monitoring modules for optoelectronic safety components
Note• Input level: The example shows a2-channel control circuit with a safety lightgrid, an external reset buttonJ and afeedback circuitS.
• The control recognises cross-short,cable break and earth leakages in themonitoring circuit.
• F1 = hybrid fuse• Relay outputs: Suitable for 2 channel con-trol, for increase in capacity or number ofcontacts by means of contactors or relayswith positive-guided contacts.
• Switch setting:The cross-wire short detection function(factory default) is programmed by meansof the switch located underneath the frontcover of the module:Position nQS (top):no cross-wire short protection, suitablefor 1-channel applications and applicationswith outputs with potential in the controlcircuits.Position QS (bottom):cross-wire short protection, suitable for2-channel applications without outputswith potential in the control circuits.
• Connect potential p-type outputs ofsafety light grids/curtains to S12/S22.The devices must have the same referencepotential. (QS-switch = nQS)
• Automatic start:The automatic start is programmed byconnecting the feedback circuit to theterminals S12/X3. If the feedback circuitis not required, establish a bridge
LEDThe integrated LED’s indicate the followingoperating conditions:• Position relay K1• Position relay K2• Supply voltage UB
• Internal operating voltage Ui
Wiring diagram
K1 K2
F1
UB Ui
A1 S12 S11 S21
L1
K1
K2
13 23S22
A2 14 24
33
34
41
Ansteuerlogik/
Logic
nQS
QS
SJ
42
N
X3 X2
KA
KB
KB
KB
KA
KA
NoteThe wiring diagram is shown for the de-energized condition.
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means ofa suitable circuit.
• Suitable for signal processing of outputsconnected to potentials (AOPDs),e.g. safety light grids/curtains
• 1 or 2 channel control• 2 safety contacts, STOP 0• 1 safety contacts, STOP 1• 1 signalling output (NC)• With hybrid fuse• Reset with edge detection or automaticreset function
• 4 LEDs to show operating conditions• Category 4 to EN 954-1• Plug-in screw connection
Ordering detailsSCR 211
Technical dataStandards: IEC/EN 60204-1, EN 60947-5-3, EN 954-1, BG-GS-ET-14, BG-GS-ET-20Start conditions: Automatic or start buttonFeedback circuit (Y/N): yesON delay with automatic start: ≤ 40 msDrop-out delay in case of emergency stop: ≤ 50 msRated operating voltage Ue: 24 VAC/DCFrequency range: 50 / 60 HzFuse rating for the operating voltage: Internal electronic trip, tripping current > 1.0 A,
Reset after disconnection of supply voltageInternal electronic protection (Y/N): yesPower consumption: 5.1 W; 5.7 VA, plus signalling outputMonitored inputs:Short-circuit recognition: noWire breakage detection: yesEarth connection detection: yes
Number of NC contacts: 2Number of NO contacts: 0Max. conduction resistance: 40 ΩOutputs:Stop category 0: 2Stop category 1: 1Number of safety contacts: 3Number of auxiliary contacts: 0Number of signalling outputs: 1Max. switching capacity of the safety contacts: 250 VAC, 4 A ohmic (inductive in
case of appropriate protective wiring)Utilisation category to EN 60947-5-1: 13-14, 23-24: AC-15: 230 V / 1.5 A, DC-13: 24 V / 1.2 A;
37/38: AC-15: 230 V / 3 A, DC-13: 24 V / 2 AMechanical life: 107 operationsAmbient conditions:Ambient temperature: -25°C…+45°CStorage and transport temperature: -25°C…+70°CProtection class: Enclosure: IP 40, Terminals: IP 20, Clearance: IP 54Mounting: Snaps onto standard DIN rail to EN 60715Connection type: Screw connection, plug-inmin. cable section: 0.25 mm2
max. cable section: 2.5 mm2
Weight: 255 gDimensions (Height/Width/Depth): 100 x 22.5 x 121 mmClassification:Standards: EN ISO 13849-1; IEC 61508; IEC 60947-5-3PL: up to eCategory: up to 4PFH value: 5.0 x 10-9 /h for max. 36,500 switching cycles/year and max. 60% contact loadSIL: up to 3Mission time: 20 years
Approvals
Safety monitoring modules for optoelectronic safety components
Note• Input level: The example shows a2-channel control circuit with a safety lightgrid, an external reset buttonJ and afeedback circuitS.
• The control system recognises wire-breakage and earth faults in themonitoring circuit.
• Relay outputs: Suitable for 2 channelcontrol, for increase in capacity or numberof contacts by means of contactors orrelays with positive-guided contacts.
• Automatic start:The automatic start is programmed byconnecting the feedback circuit to theterminals X1/X3. If the feedback circuitis not required, establish a bridge
Wiring diagram
K4K1 K2 K3UB Ui
F1
A1
L1
N
K1
K2
A2 24 3814
13 23 37
S
Y1
S12 S11 S22 X1 X2 X3S11
K3
K4
KA
KB
KC
KD
KA
KB
KD
KC
KA
KB
KC
KD
Ansteuerlogik/
Control circuit
J
LEDThe integrated LED’s indicate the followingoperating conditions:• Position relay K1• Position relay K2• Internal operating voltage Ui
• Position relay K3/4
NoteThe wiring diagram is shown for the de-energized condition.
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means ofa suitable circuit.
Safety monitoring modules for optoelectronic safety components
Start interlock:A device preventing the auto-matic release and thereforethe automatic machine startwhen the power supply ofthe AOPD is switched on orinterrupted and switched onagain.
AOPD:The abbreviation of ActiveOptoelectronic ProtectiveDevice.
Resolution:The resolution or minimumobject sensitivity representsthe minimum size of an ob-ject that is detected in eachpart of the protection field.
Optoelectronic safetydevices:The here described areoptoelectronic safety guards(AOPD), e.g. safety lightbarriers, safety light curtainsand safety light grids as wellas laser scanners and theircorresponding safety relaymodules
Type 2 acc. to EN 61496-1:The Type 2 AOPD is aprotective device, whosesafety function is checkedby means of regular tests.These devices must meetthe requirements of PLc toEN ISO 13849-1, or ControlCategory 2 acc. to EN 954-1.
Type 4 acc. to EN 61496-1:The Type 4 AOPD is a protec-tive device, whose safetyfunction is not affected by afailure or error in the system.These devices must meet therequirements of PLe to ENISO 13849-1, or ControlCategory 4 acc. to EN 954-1.
Blanking:In this configurable operationmode a safety light curtainblanks out a precisely definedarea in the protection field.The operation mode. “Blank-ing“ allows objects to bepresent in the sending areawith out deactivating the lightcurtain safety outputs. “FixedBlanking“ is when a fixed setof adjacent light beams arerendered inactive for the pur-pose of entering an objectand pans into the protectivearea. “Floating Blanking“ iswhen a set member (one ormore) of adjacent beams isallowed to ignore the pres-ence of an object and not de-activating the OSSDs of thelight curtain.
Muting:Muting is a temporaryautomatic suspension of asafeguarding function bysafety-related parts of thecontrol system duringotherwise safe conditions inthe operation of a machine.The safeguarding functionis realized through 2 or 4muting sensors, which candistinguish between personsand objects. The suspensioncondition is signalled bymeans of a muting signallamp.
OSSD:Output Signal SwitchingDevice of the AOPD(to EN 61496)
Protection field:The protection zone is aninvisible, two-dimensionallight curtain consisting ofinfrared light beams, installedbetween the emitter andreceiver unit.
Depending on the chosenresolution (detection sensitivi-ty) objects of a specific sizeintruding this light curtain willbe detected.
Operating Range:The operating range is themaximum distance that mayexit between the light cur-tain’s emitter and its receiver.
Protected height:The protected height is avertical area between the firstand the last infrared lightbeam of an optoelectronicsafety guard (not the totalhousing length).
The beginning and the endof this area is marked withsymbols on the SLC/SLG’senclosure.
Restart interlock:A device preventing the auto-matic restart of the machine,when the protection field isinterrupted during a danger-ous machine cycle or whenthe operating mode of themachine is set or changed.