Dräger LAR 5002 Diving Equipment and Systems The Dräger LAR 5002 is a non-magnetic closed-circuit diving apparatus for special operations diving. It is designed for use with pure oxygen and depths up to 10 metres. The device function has been streamlined for especially easy handling and can be prepared for diving in just a few minutes with no tools required. D-7325-2016 Adjustable lung demand valve for tactical ascent support Oxygen cylinder Pressure gauge (in housing) Manual bypass Robust housing
8

minutes with no tools required. Diving Equipment and ...

Apr 14, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: minutes with no tools required. Diving Equipment and ...

Dräger LAR 5002Diving Equipment and Systems

The Dräger LAR 5002 is a non-magnetic closed-circuit diving apparatusfor special operations diving. It is designed for use with pure oxygenand depths up to 10 metres. The device function has been streamlinedfor especially easy handling and can be prepared for diving in just a fewminutes with no tools required.

D-7

325-2

016

Adjustable lung demand valve

for tactical ascent support

Oxygen cylinder

Pressure gauge (in housing)

Manual bypass

Robust housing

Page 2: minutes with no tools required. Diving Equipment and ...

Benefits

02 | Dräger LAR 5002

Non-magnetic

The Dräger LAR 5002 is a non-magnetic diving apparatus conforming to STANAG 2897, class A. All devicecomponents are designed and dimensioned according to the standard.

Adjustable lung demand valve

The adjustable lung demand valve supports tactical ascent. The time at which the lung demand valve opens caneasily be changed in order to optimise the use of the available oxygen during ascent. This ensures a bubble-free ascent.

Easy and quick assembly

The LAR 5002 is quickly assembled and ready to use in just a few simple steps – no tools necessary. It can beassembled even in poor lighting conditions or confined spaces.

Robust housing

All components of the diving apparatus are protected by a robust housing. Thanks to this housing, the LAR5002 can be used in extreme environments or challenging conditions. You can trust that the components areprotected even when the apparatus is thrown off or dropped.

Simple cylinder adaptation

The cylinder straps of the Dräger LAR 5002 can easily fit cylinders of different diameters without usingextension equipment. Cylinders of different materials and different volumes are available.

Reliability

Thanks to the robust design and extremely high reliability of the diving apparatus, it is widely used. Specialoperations around the world rely on the high quality of the LAR product range.

Page 3: minutes with no tools required. Diving Equipment and ...

Accessories

Dräger LAR 5002 | 03

D-7

7428

-201

3

Dräger DiveSorb® Pro

The Dräger DiveSorb® Pro was developed specifically for closedor semi-closed rebreathers in order to allow a high degree of CO2

absorption, and thus long dive times.

ST-2

671-

2004

Dräger Panorama Nova Dive

The Panorama Nova Dive is based on a tried and tested mask body.Together with the 5-point harness it provides an excellent, tight fit.

D-1

1306

-201

6

Oxygen and mixed gas cylinders

Both non-magnetic and magnetic oxygen cylinders are available.

D-1

1943

-201

6

Transport case for the Dräger LAR 5002

The robust transport case can be used to safely store and transport theDräger LAR 5002 and its accessories. The cases can be stacked.

Page 4: minutes with no tools required. Diving Equipment and ...

Services

04 | Dräger LAR 5002

D-2

331-

2016

Product Service

Our product service department supports you with a range of servicepackages – in our shops or on site in your plant. Care, servicingand maintenance are key factors when it comes to safety. Diligentmaintenance and care is also absolutely necessary from an economicsperspective. Preventive checks, service procedures and originalreplacement parts make your investment last longer.

D-2

335-

2016

Training

The Dräger Academy has imparted well-founded and practicalknowledge for over 40 years. With over 110 authorized trainers andmore than 600 available topics, we conduct more than 2,400 trainingsessions per year. We equip your employees with the knowledgerequired for real-life situations and ensure that the learned material canbe recalled and applied reliably – in their everyday work and especiallyin stressful situations. To meet your needs, we are also happy todevelop a customized training program specifically for you.

Related Products

ST-1

5412

-200

8

Dräger LAR 5000

LAR 5000 is a very streamlined and compact diving apparatus forspecial operations diving. Optionally the apparatus can be suppliedfrom a nitrox regulator for submarine lock-out. With its fold-in pressuregauge, LAR 5000 embodies a streamlined rebreather for military use.

Page 5: minutes with no tools required. Diving Equipment and ...

Related Products

Dräger LAR 5002 | 05

D-7

7432

-201

3

Dräger LAR 5010

LAR 5010 is a closed-circuit diving apparatus for special operationsdiving. Optionally, the apparatus can be supplied with Nitrox B to enablediving depths of 24 m. LAR 5010 offers the additional option to be back-carried.

ST-4

01-2

008

Dräger LAR 7000

Dräger LAR 7000 is a very versatile diving apparatus for all facets ofshallow water diving, including VSW – MCM diving and submarine lock-out as well as special operations diving.

ST-1

5413

-200

8

Dräger LAR VII Combi FA

Dräger LAR VII Combi FA is a very versatile and compact divingapparatus for all facets of shallow water diving, including VSW – MCMdiving and submarine lock-out as well as special operations diving.

Page 6: minutes with no tools required. Diving Equipment and ...

Technical Data

06 | Dräger LAR 5002

Dräger LAR 5002 basic unitDescription Closed-circuit with lung demand valveDiving depth 0 to 10 metresDiving duration 240 min With RMV 22.5 L/min / 4°CBreathing gas Pure oxygenBreathing bag Flexible volume approx. 5.5 L / available

volume approx. 10 LSoda lime Dräger DiveSorb® Pro; approx. 2.3 kg per

fillingMagnetic signature STANAG 2897, class ADimensions Length 425 mm, width 300 mm,

depth 170 mmWeight In air Approx. 13 kg

In water Neutral

Operating temperature -2°C to 40°CStorage temperature -40°C to 50°C

Cylinder dataOxygen cylinder Non-magnetic (NM)

(STANAG 2897)Low magnetic (LM) Magnetic

Volume 2.0 L 1.9 L 1.5 LDiameter 140 mm 134 mm 115 mmNominal pressure 200 bar 200 bar 200 barConnection G 3/4" G 3/4" G 3/4"Material Composite Aluminium SteelApprovals TÜV DOT3AL TÜVPositioning Under the diving apparatus Under the diving apparatus Under the diving apparatus

Ordering Information

Dräger LAR 5002 T 15 002

CylindersOxygen cylinder – NM, 2 L, with valve, black, STANAG A T 16 991Oxygen cylinder – LM, 1.9 L, with valve, black T 17 353Oxygen cylinder – magnetic, 1.5 L, with valve, black, steel B 03 961

AccessoriesTransport case, plastic, large, with foam inlays T 16 956Tactical harness 1000 – basic version, size S T 92 169Tactical harness 1000 – basic version, size M T 92 161Tactical harness 1000 – basic version, size L T 92 165Tactical harness 1000 – basic version, size XL T 92 166Diving mask, black, magnetic T 53 307Diving mask, black, non-magnetic T 16 471

ToolsTool bag T 14 410Tool bag, non-magnetic T 16 405

Page 7: minutes with no tools required. Diving Equipment and ...

Ordering Information

Dräger LAR 5002 | 07

Spare partsSpare parts set T 14 411

Consumables

Dräger DiveSorb® Pro, 4.5 kg / for two dives 67 37 062

Dräger DiveSorb® Pro, 18 kg / for eight dives 67 37 109Halocarbon grease (28 g per tube) 65 90 212Silicone grease W410 (100 g per tube) for mouthpiece 15 95 008

Page 8: minutes with no tools required. Diving Equipment and ...

Notes

08 | Dräger LAR 5002

Not all products, features, or services are for sale in all countries.Mentioned Trademarks are only registered in certain countries and not necessarily in the countryin which this material is released. Go to www.draeger.com/trademarks to find the current status.

CORPORATE HEADQUARTERSDrägerwerk AG & Co. KGaAMoislinger Allee 53–5523558 Lübeck, Germanywww.draeger.com

REGION DACHDräger Safety AG & Co. KGaARevalstraße 123560 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 [email protected] EUROPEDräger Safety AG & Co. KGaARevalstraße 123560 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 [email protected].

REGION MIDDLE EAST, AFRICADräger Safety AG & Co. KGaABranch OfficeP.O. Box 505108Dubai, United Arab EmiratesTel +971 4 4294 600Fax +971 4 4294 [email protected] ASIA PACIFICDraeger Singapore Pte. Ltd.61 Science Park RoadThe Galen #04-01Singapore 117525Tel: +65 6872 9288Fax: +65 6259 [email protected].

REGION CENTRALAND SOUTH AMERICADraeger Panamá ComercialS. de R.L.59 East Street, Nuevo Paitilla,House 31, San Francisco TownPanama City, PanamaTel +507 377-9100 / Fax [email protected].

Locate your Regional SalesRepresentative at:www.draeger.com/contact

91 0

2 57

2 |

19.0

6-2

| H

Q |

PP

| S

ubje

ct to

mod

ifica

tions

| ©

201

9 D

räge

rwer

k AG

& C

o. K

GaA