Method-Specific Sample Preparation for EPH AnalysisResprep SPE Cartridges for Complete Extractable Petroleum Hydrocarbon Fractionation
www.restek.com
• Full separation between fractions.
• Guaranteed low background level.
• Superior lot-to-lot reproducibility.
2 www.restek.com
Figure 1: Resprep EPH SPE cartridges offer consistent and complete separation between aliphatic and aromatic compounds from one lot to the next. A representative subset of compounds is shown here (40+ compounds were analyzed in total) to clearly illustrate the separation between fractions and the lack of breakthrough in every lot we produce.
• Method-specific performance for extractable petroleum hydrocarbon (EPH) analysis of soil and water samples.
• Complete separation of aliphatic and aromatic compounds into distinct fractions.
• Guaranteed background level under the strict reporting limits of MA and NJ EPH methods.
• Superior lot-to-lot reproducibility and storage stability ensured by rigorous QC testing and moisture-resistant packaging.
Resprep EPH fractionation SPE cartridges from Restek are manufactured in a strictly controlled environment with the simple goal of giving you consistent results—every day, every time. Turn to Resprep cartridges for easy, reproducible, and guaranteed extractable petroleum hydrocarbon analysis.
No guesswork, no worries.Detailed, step-by-step instructions and a complete certificate of analysis are included with every 15-pack of Resprep EPH cartridges.
www.restek.com 3
Figure 2: Storage stability is enhanced by new, moisture-resistant packaging that prevents ambient moisture from reaching your SPE cartridge and helps ensure outstanding performance.
Moisture Content after Storage in 80% Relative Humidity
0.000.501.001.502.002.503.003.504.004.505.00
0 1 2 3 4 6 8 10 12 16 20 24
Moi
stur
e (%
)
Storage Time (weeks)
Table I: Recovery data (n = 3) for Resprep EPH SPE cartridges. Again, 40+ compounds were analyzed; shown here are the compounds most critical to method requirements.
Compound Concentration (ppm) Function Average % Recovery %RSD
Figure 3: Restek guarantees a background level in each fraction of less than half the strict reporting limits of MA and NJ EPH methods.
1-Chlorooctadecane at 5 ppm
Time (min)
5 7.5 10 12.5 15 17.5 20 22.5 25
Region 1Total extracted background = 8.2 ppm
Region 2Total extracted background = 11.5 ppm
EPH Silica Cartridge Background Extraction Aliphatic Fraction on Rxi-5ms
GC_EV1437
Conc. Peaks tR (min) (µg/mL)1. 1-Chlorooctadecane 15.679 5
Column Rxi-5ms, 30 m, 0.32 mm ID, 0.25 µm (cat.# 13424)Sample MA EPH surrogate spike mix (cat.# 31479)Conc.: 5 µg/mL InjectionInj. Vol.: 1 µL splitless (hold 1 min)Liner: Restek Premium 4.0 mm ID cyclo double taper inlet liner
(cat.# 23310)Inj. Temp.: 300 °CPurge Flow: 50 mL/minOven Oven Temp.: 40 °C (hold 1 min) to 300 °C at 12 °C/min to 330 °C at 6 °C/minCarrier Gas He, constant flowFlow Rate.: 2 mL/minLinear Velocity: 41.0 cm/sec @ 40 °CDead Time: 1.12 min @ 40 °CDetector FID @ 330 °CMake-up Gas Flow Rate: 45 mL/minMake-up Gas Type: N₂Hydrogen flow: 40 mL/minAir flow: 450 mL/minData Rate: 50 HzInstrument Agilent 7890B GCNotes The area of the surrogate peak was excluded from the
calculated total extracted background value for Region 2.
Conc. Peaks tR (min) (µg/mL)1. o-Terphenyl 14.177 5
Time (min)
Region 1Total extracted background = 14.2 ppm
Region 2Total extracted background = 13.1 ppm
o-Terphenyl at 5 ppm
5 7.5 10 12.5 15 17.5 20 22.5 25
EPH Silica Cartridge Background Extraction Aromatic Fraction on Rxi-5ms
• Method-specific performance for extractable petroleum hydrocarbon (EPH) analysis of soil and water samples.
• Complete separation of aliphatic and aromatic compounds into distinct fractions.• Guaranteed background level under the strict reporting limits of MA and
NJ EPH methods.• Superior lot-to-lot reproducibility and storage stability ensured by rigorous QC
testing and moisture-resistant packaging.
Product Listing
Resprep 12-Port SPE Manifold
Resprep 12- or 24-Port SPE Manifolds
• Use with any standard male luer end SPE cartridges.• Inert, PTFE sample guides reduce cross-contamination and carryover.• Flexible sample collection rack will accommodate a variety of receiving vessels.• Quick vacuum-release valve for better system control.• Individual valves allow vacuum control for each cartridge,
improving reproducibility.
Description qty. cat.#
Complete Resprep SPE Manifold, 12-Port (Includes: glass basin with built-in vacuum regulator (1); polypropylene lid with 12 individual control valves (1); 12-position collection rack (1); PTFE sample guides (12); and waste container (1).)
kit 26077
Complete Resprep SPE Manifold, 24-Port (Includes: glass basin with built-in vacuum regulator (1); polypropylene lid with 24 individual control valves (1); 24-position collection rack (1); and PTFE sample guides (24).)
kit 26080
Resprep® Manifold Replacement Parts
Description qty. cat.#
Replacement Waste Container, 12-Port ea. 24014 Replacement Vacuum Valve and Gauge Assembly ea. 24008 Glass Vacuum Chamber w/gauge & valve for Resprep manifolds, 6 or 12-Port ea. 25991
NOTE: Replacement waste container not included in 24-port manifold kit (cat.# 26080).*Waste container (shown in tank) and top shelf for round-bottom flasks are not included in 24-port manifold kit (cat.# 26080).
No-risk, no-obligation trial.Free samples of Resprep solid phase extrac-tion (SPE) tubes are available. Contact us or your local Restek representative to request yours: www.restek.com/contact-us
6 www.restek.com
100-pk. 1,000-pk.Description cat.# cat.#Amber Vial w/Graduated Marking Spot, 9 mm, Blue Cap PTFE/Silicone Liner 26596 26597
Vials packaged in a clear-lid tray. Caps with septa packaged in a plastic bag.
Cap Color Septa Material Type 100-pk. 1,000-pk.Blue PTFE/Silicone Screw-Thread 24485 24486
Choose preslit caps (available for some vials) to reduce the risk of needle bending, release vacuum from high-volume injections, and improve injection reproducibility when greater than 20% of vial volume is withdrawn.
2.0 mL, 9 mm Short-Cap, Screw-Vial Closures (Polypropylene, preassembled)
Learn more about Restek reference standards at www.restek.com/standards
Questions about this or any other Restek product? Contact us or your local Restek representative (www.restek.com/contact-us).Restek patents and trademarks are the property of Restek Corporation. (See www.restek.com/Patents-Trademarks for full list.) Other trademarks in Restek literature or on its website are the property of their respective owners. Restek registered trademarks are registered in the U.S. and may also be registered in other countries.