• Current ratings 630-5000A• Maximum rated voltage 24kV• Accepts SF6, vacuum CBs,
or vacuum contactors V Contact• Interlocking earth switch available• Metal shutters and insulators for
busbar / cable take offs• Auxiliary position indicating
switches
MV Enclosure Vacuum ContactorEnclosure Type Unimotor
• Accepts full range of Type VContactors in drawout form
• Automatic Earthing Switch• Fully Integrated• Three tier option• Integral BS Fuse carrier
Vacuum Circuit Breakers Type VM1
New operating mechanism technology
• Force generation by magnetic actuator• Latching by magnetic actuator• Released by magnetic actuator• No parts subject to wear• Maintenance-free as a
standard feature
Vacuum ContactorsType V C o n t a c t
• Single pole version available• Voltages 2.2 to 12 kV • Current ratings up to 400A• Fault levels up to 50MVA• Fixed or withdrawable versions• Withdrawable with enclosure door
closed
Switchgear in PrimaryConstruction UniGear
• Voltages up to 24kV• Current ratings up to 4000A• Fault level up to 50kA• Detachable LV enclosure
• Current ratings up to 3150A• Rated voltage 12, 17.5 and 24kV• Latest SF6 gas technology• Large interruption capacities• Compact size• Sturdy construction• Utilises PowerBox/PowerBloc
enclosure
Current Limiting FusesType CEF & CMF
• Din and BS versions• Combined indicator and striker• Low minimum breaking current• Small power loss• Low arc voltage• High breaking capacity• High current limitation• Fuse base with striker pin
assembly available
Fuse Switch DisconnectorType NALF
• Manual/remote operation• Interlocking earth
switch available• Additional fuse base options• Voltages up to 36 kV• Current ratings 400A to 1250A• Making capacity 1550MVA
@ 36 kV• Castell, Lowe & Fletcher
interlocking facility
Off-Load IsolatorType OJON
• Single pole version available• Voltages 12 to 24 kV • Current ratings up to 150kA peak• Independent mounting• Auxilliary switches• Castell, Lowe & Fletcher
interlocking facility
Switch Disconnector Type C3
• Voltages upto 24kV• Current ratings upto 1250A• Rod operation, compact design• Fuse base & earth switch integral• Range of accessories including
motor operator
Earthing SwitchType OJWN
• Voltages 12 to 24 kV • Up to 40kA for 3 seconds• Independent mounting• Compact design• Wide range of operating
Unisafe is a medium voltage, metal-clad switch board suitable for indoor applications.It is a modular apparatus made of aligned standard units.Metal sheets segregate each compartment and the energised components are air insulated.The arc-proof units have been tested in compliance with IEC 60298 Standards (app. AA, class Aaccessibility, criteria 1 to 6).The installation requires very simple civil works.The switchboard can be wall-mounted.The power cables branch connectors are accessible from the front.
Protection Degrees
The protection degrees in compliance with IEC60529 Standards are the following:• IP4X on the external housing• IP2X inside the compartments.On request, the external housing can be manufactured so as to guarantee different protection degrees upto a maximum of IP53.
Main electrical characteristics
Rated Voltage 12-17.5 kV 24 kV 36 kVRated Current ...2500 A ...2000 A ...2500 ARated short time ...31.5 kA ...25 kA ...25 kAwithstand current
The electrical characteristics can change depending on different ambient conditions or on protectiondegrees higher than the standard values.
Standard Colour
RAL7035
Compliance with standards
The switchboard and its components comply with the following International and European standards:
Medium Voltage current limiting fuse liks for motor circuit applicationstype CMF-BS & DIN
1. General
The fuse links type CMF are specially designed for motor circuit applications.They are tested according tothe IEC Publication 282-1 and Publication 644. The IEC 644 applies to fuse links used with motors starteddirect-on-line on alternating current systems. High voltage fuses used in motor circuits must have the abilityto withstand, without deterioration, the repeated surges associated with motor starting.
The dimensions are in accordance with DIN 43625, i.e. the 3.6kV rating is realized in the normal 12kYlength (e=292mm). The 7.2kV and 12kV rating in the 24kV length (e=442mm).Special connection elementscan be delivered in cases where fuses have to be parallelled.
ABB’s motor fuses have the following properties:• higher current rating with single body dimensions• tested according to IEC 644 which guarantees excellent ability to withstand repeated motor startingconditions.• low power losses• low minimum-breaking-capacity• high breaking capacity and excellent short circuit current limitation.
Although a motor fuse is normally run at a stationary current which is much lower than the fuse ratedcurrent, the low loss characteristics of the CMF fuses make them specially suitable in compact contactorcompartments.