Top Banner
7

Material Safety Data Sheet - Ingersoll Rand Air ... · Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014 Page 3 of 9 Hazardous combustion products: During a fire,

Apr 07, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Material Safety Data Sheet - Ingersoll Rand Air ... · Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014 Page 3 of 9 Hazardous combustion products: During a fire,

® ™ Trademark of Ingersoll Rand or an affiliated

company of Ingersoll Rand Page 1 of 9

Material Safety Data Sheet

Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014Print Date: 13.05.2015

INGERSOLL RAND encourages and expects you to read and understand the

entire (M)SDS, as there is important information throughout the document. We expect you to follow the precautions identified in this document unless your use conditions would necessitate other appropriate methods or actions.

1. PRODUCT AND COMPANY IDENTIFICATION

Product name: Ingersoll Rand Techtrol Gold III Recommended use of the chemical and restrictions on use Identified uses: Selection of the appropriate polyglycol product for a specific application requires knowledge of the fluid requirements of the application, awareness of the most important of these requirements, and a match-up with the properties of the various polyglycol materials. Polyglycol products can be formulated for use in numerous industry applications such as hydraulic fluids, quenchants, compressor and refrigeration lubricants, heat transfer fluids, machinery lubricants, solder assist fluids, metalworking lubricants, textile finishing, etc. COMPANY IDENTIFICATION

Customer Information Number:

EMERGENCY TELEPHONE NUMBER

2. HAZARDS IDENTIFICATION

Classification of the substance or mixture HAZARDOUS SUBSTANCES CLASSIFICATION: Not classified as hazardous to health according to the criteria of the National Occupational Health and Safety Commission, Australia Other hazards no data available

INGERSOLL RAND

U.S. 24-Hour Emergency #: 800-424-9300 Outside U.S. Emergency #: +01 703-527-3887

+01 704-655-4000

INGERSOLL RAND DISTRIBUTED BY

800D BEATY ST DAVIDSON, NC 28036 UNITED STATES

Page 2: Material Safety Data Sheet - Ingersoll Rand Air ... · Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014 Page 3 of 9 Hazardous combustion products: During a fire,

Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014

Page 2 of 9

This product is a mixture

.

CASRN / EC

-No.

/ Index-No.

Concentration Component Classification

CASRN Confidential

EC-No. Polymer

Index-No. –

> 60.0 - < 70.0 % Polypropylene Glycol Not classified

CASRN Confidential

EC-No. Confidential Index-No.

> 25.0 - < 30.0 % Pentaerythritol ester Not classified

4. FIRST AID MEASURES

Description of first aid measures General advice: If potential for exposure exists refer to Section 8 for specific personal protective equipment. Inhalation: Move person to fresh air; if effects occur, consult a physician. Skin contact: Wash off with plenty of water. Eye contact: Flush eyes thoroughly with water for several minutes. Remove contact lenses after the initial 1-2 minutes and continue flushing for several additional minutes. If effects occur, consult a physician, preferably an ophthalmologist. Ingestion: No emergency medical treatment necessary. Most important symptoms and effects, both acute and delayed: Aside from the information found under Description of first aid measures (above) and Indication of immediate medical attention and special treatment needed (below), any additional important symptoms and effects are described in Section 11: Toxicology Information. Indication of any immediate medical attention and special treatment needed Notes to physician: No specific antidote. Treatment of exposure should be directed at the control of symptoms and the clinical condition of the patient.

5. FIREFIGHTING MEASURES

Suitable extinguishing media: Water fog or fine spray. Dry chemical fire extinguishers. Carbon dioxide fire extinguishers. Foam. Alcohol resistant foams (ATC type) are preferred. General purpose synthetic foams (including AFFF) or protein foams may function, but will be less effective. Unsuitable extinguishing media: Do not use direct water stream. May spread fire. Special hazards arising from the substance or mixture

3. COMPOSITION/INFORMATION ON INGREDIENTS

Page 3: Material Safety Data Sheet - Ingersoll Rand Air ... · Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014 Page 3 of 9 Hazardous combustion products: During a fire,

Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014

Page 3 of 9

Hazardous combustion products: During a fire, smoke may contain the original material in addition to combustion products of varying composition which may be toxic and/or irritating. Combustion products may include and are not limited to: Nitrogen oxides. Carbon monoxide. Carbon dioxide. Unusual Fire and Explosion Hazards: Container may rupture from gas generation in a fire situation. Violent steam generation or eruption may occur upon application of direct water stream to hot liquids. Advice for firefighters Fire Fighting Procedures: Keep people away. Isolate fire and deny unnecessary entry. Use water spray to cool fire exposed containers and fire affected zone until fire is out and danger of reignition has passed. Fight fire from protected location or safe distance. Consider the use of unmanned hose holders or monitor nozzles. Immediately withdraw all personnel from the area in case of rising sound from venting safety device or discoloration of the container. Do not use direct water stream. May spread fire. Move container from fire area if this is possible without hazard. Burning liquids may be moved by flushing with water to protect personnel and minimize property damage. Special protective equipment for firefighters: Wear positive-pressure self-contained breathing apparatus (SCBA) and protective fire fighting clothing (includes fire fighting helmet, coat, trousers, boots, and gloves). If protective equipment is not available or not used, fight fire from a protected location or safe distance.

6. ACCIDENTAL RELEASE MEASURES

Personal precautions, protective equipment and emergency procedures: Use appropriate safety equipment. For additional information, refer to Section 8, Exposure Controls and Personal Protection. Refer to section 7, Handling, for additional precautionary measures. Environmental precautions: Material will float on water. Prevent from entering into soil, ditches, sewers, waterways and/or groundwater. See Section 12, Ecological Information. Methods and materials for containment and cleaning up: Contain spilled material if possible. Collect in suitable and properly labeled containers. See Section 13, Disposal Considerations, for additional information.

7. HANDLING AND STORAGE

Precautions for safe handling: No special precautions required. Do not use sodium nitrite or other nitrosating agents in formulations containing this product. Suspected cancer-causing nitrosamines could be formed. Spills of these organic materials on hot fibrous insulations may lead to lowering of the autoignition temperatures possibly resulting in spontaneous combustion. Conditions for safe storage: Store in the following material(s): 316 stainless steel. Carbon steel. Glass-lined container. Polypropylene. Polyethylene-lined container. Stainless steel. Teflon. This material may soften and lift certain paint and surface coatings. Use product promptly after opening. Store in original unopened container. Unopened containers of material stored beyond the recommended shelf life should be retested against the sales specifications before use. Additional storage and handling information on this product may be obtained by calling your sales or customer service contact. C2 Combustible Liquid - according to AS1940 - Storage and Handling of Flammable and Combustible Liquids. Store in accordance with regulations for storage of combustible liquids.

Page 4: Material Safety Data Sheet - Ingersoll Rand Air ... · Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014 Page 3 of 9 Hazardous combustion products: During a fire,

Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014

Page 4 of 9

Storage stability Shelf life: Use within

24 Month

8. EXPOSURE CONTROLS/PERSONAL PROTECTION

Control parameters Exposure limits are listed below, if they exist. None established Exposure controls Engineering controls: Use local exhaust ventilation, or other engineering controls to maintain airborne levels below exposure limit requirements or guidelines. If there are no applicable exposure limit requirements or guidelines, general ventilation should be sufficient for most operations. Local exhaust ventilation may be necessary for some operations. Individual protection measures

Eye/face protection: Use safety glasses (with side shields). Skin protection

Hand protection: Use gloves chemically resistant to this material when prolonged or frequently repeated contact could occur. Use chemical resistant gloves classified under standard AS/NZS 2161.10: Protective gloves against chemicals and micro-organisms. Examples of preferred glove barrier materials include: Butyl rubber. Ethyl vinyl alcohol laminate (“EVAL”). Examples of acceptable glove barrier materials include: Natural rubber (“latex”). Neoprene. Nitrile/butadiene rubber (“nitrile” or “NBR”). Polyvinyl chloride (“PVC” or “vinyl”). Viton. When prolonged or frequently repeated contact may occur, a glove with a protection class of 4 or higher (breakthrough time greater than 120 minutes according to AS/NZS 2161.10) is recommended. When only brief contact is expected , a glove with a protection class of 1 or higher (breakthrough time greater than 10 minutes according to AS/NZS 2161.10) is recommended. NOTICE: The selection of a specific glove for a particular application and duration of use in a workplace should also take into account all relevant workplace factors such as, but not limited to: Other chemicals which may be handled, physical requirements (cut/puncture protection, dexterity, thermal protection), potential body reactions to glove materials, as well as the instructions/specifications provided by the glove supplier. Other protection: When prolonged or frequently repeated contact could occur, use protective clothing chemically resistant to this material. Selection of specific items such as faceshield, boots, apron, or full-body suit will depend on the task.

Respiratory protection: Under intended handling conditions, no respiratory protection should be needed.

Other Information: Selection and use of personal protective equipment should be in accordance with the recommendations in one or more of the relevant Australian/New Zealand Standards, including: AS/NZS 1336: Recommended practices for occupational eye protection. AS/NZS 1337: Personal eye protection - Eye and face protectors for occupational applications. AS/NZS 1715: Selection, use and maintenance of respiratory protective equipment. AS/NZS 2161: Occupational protective gloves. AS/NZS 2210: Occupational protective footwear. AS/NZS 4501: Occupational protective clothing Set

Page 5: Material Safety Data Sheet - Ingersoll Rand Air ... · Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014 Page 3 of 9 Hazardous combustion products: During a fire,

Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014

Page 5 of 9

9. PHYSICAL AND CHEMICAL PROPERTIES

Appearance

Physical state Liquid.

Color Yellow to brown

Odor Mild

Odor Threshold No test data available

pH 8 - 10 DOWM 101495 (16% in water/methanol, 1:10)

Melting point/range Not applicable to liquids

Freezing point See Pour Point

Boiling point (760 mmHg) > 200 °C Calculated.

Flash point closed cup 234 °C ASTM D 93

Evaporation Rate (Butyl Acetate = 1)

No test data available

Flammability (solid, gas) Not applicable to liquids

Lower explosion limit No test data available

Upper explosion limit No test data available

Vapor Pressure < 0.01 mmHg at 20 °C ASTM E1719

Relative Vapor Density (air = 1) No test data available

Relative Density (water = 1) 0.9850 at 25 °C / 25 °C ASTM D941

Water solubility < 0.1 % at 20 °C Measured

Partition coefficient: n-octanol/water

no data available

Auto-ignition temperature No test data available

Decomposition temperature No test data available

Kinematic Viscosity 25 - 28 cSt at 37.8 °C ASTM D 445

Explosive properties no data available

Oxidizing properties no data available

Liquid Density 0.9826 g/cm3 at 25 °C ASTM D941

Molecular weight no data available

pour point < 0 °C ASTM D97

NOTE: The physical data presented above are typical values and should not be construed as a specification.

10. STABILITY AND REACTIVITY

Reactivity: no data available Chemical stability: Thermally stable at typical use temperatures. Possibility of hazardous reactions: Polymerization will not occur.

Page 6: Material Safety Data Sheet - Ingersoll Rand Air ... · Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014 Page 3 of 9 Hazardous combustion products: During a fire,

Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014

Page 6 of 9

Conditions to avoid: Exposure to elevated temperatures can cause product to decompose. Generation of gas during decomposition can cause pressure in closed systems. Incompatible materials: Avoid contact with: Strong acids. Strong bases. Strong oxidizers. Hazardous decomposition products: Decomposition products depend upon temperature, air supply and the presence of other materials. Decomposition products can include and are not limited to: Aldehydes. Alcohols. Ethers. Hydrocarbons. Ketones. Organic acids. Polymer fragments.

11. TOXICOLOGICAL INFORMATION

Toxicological information on this product or its components appear in this section when such data is available. Acute toxicity

Acute oral toxicity Very low toxicity if swallowed. Harmful effects not anticipated from swallowing small amounts. As product: Single dose oral LD50 has not been determined. For similar material(s): LD50, rat, > 5,000 mg/kg Acute dermal toxicity Prolonged skin contact is unlikely to result in absorption of harmful amounts. As product: The dermal LD50 has not been determined. For similar material(s): LD50, rabbit, > 2,000 mg/kg No deaths occurred at this concentration. Acute inhalation toxicity At room temperature, exposure to vapor is minimal due to low volatility; single exposure is not likely to be hazardous. For respiratory irritation and narcotic effects: No relevant data found. As product: The LC50 has not been determined.

Skin corrosion/irritation Brief contact is essentially nonirritating to skin. Repeated contact may cause severe skin irritation with local redness and discomfort. Serious eye damage/eye irritation May cause slight temporary eye irritation. Corneal injury is unlikely. Sensitization For similar material(s): Did not cause allergic skin reactions when tested in guinea pigs. For respiratory sensitization: No relevant data found.

Page 7: Material Safety Data Sheet - Ingersoll Rand Air ... · Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014 Page 3 of 9 Hazardous combustion products: During a fire,

Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014

Page 7 of 9

Specific Target Organ Systemic Toxicity (Single Exposure) Evaluation of available data suggests that this material is not an STOT-SE toxicant. Specific Target Organ Systemic Toxicity (Repeated Exposure) Based on available data, repeated exposures to small amounts are not anticipated to cause significant adverse effects. Carcinogenicity No specific, relevant data available for assessment. Teratogenicity No specific, relevant data available for assessment. Reproductive toxicity No specific, relevant data available for assessment. Mutagenicity No relevant data found. Aspiration Hazard Based on physical properties, not likely to be an aspiration hazard. COMPONENTS INFLUENCING TOXICOLOGY: Polypropylene Glycol

Acute inhalation toxicity At room temperature, exposure to vapor is minimal due to low volatility; single exposure is not likely to be hazardous. For respiratory irritation and narcotic effects: No relevant data found. As product: The LC50 has not been determined.

12. ECOLOGICAL INFORMATION

Ecotoxicological information on this product or its components appear in this section when such data is available. Ecotoxicity

Acute toxicity to fish Material is not classified as dangerous to aquatic organisms (LC50/EC50/IC50/LL50/EL50 greater than 100 mg/L in most sensitive species). LL50, Oncorhynchus mykiss (rainbow trout), static test, 96 Hour, > 100 mg/l Acute toxicity to aquatic invertebrates EL50, Daphnia magna (Water flea), static test, 48 Hour, > 100 mg/l

Persistence and degradability

Biodegradability: Based on information for a similar material: Material is inherently biodegradable (reaches > 20% biodegradation in OECD test(s) for inherent biodegradability). Based on stringent OECD test guidelines, this material cannot be considered as readily

Page 8: Material Safety Data Sheet - Ingersoll Rand Air ... · Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014 Page 3 of 9 Hazardous combustion products: During a fire,

Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014

Page 8 of 9

biodegradable; however, these results do not necessarily mean that the material is not biodegradable under environmental conditions. 10-day Window: Fail Based on information for a similar material: Biodegradation: < 41 % Exposure time: 28 d Method: OECD Test Guideline 301F or Equivalent 10-day Window: Not applicable Based on information for a similar material: Biodegradation: 84 % Exposure time: 28 d Method: OECD Test Guideline 302B or Equivalent

Bioaccumulative potential

Bioaccumulation: No data available for this product. Mobility in Soil

No data available.

Results of PBT and vPvB assessment This mixture has not been assessed for persistence, bioaccumulation and toxicity (PBT).

Other adverse effects

No specific, relevant data available for assessment.

13. DISPOSAL CONSIDERATIONS

Disposal methods: Any disposal practice must be in compliance with all local and national laws and regulations. Do not dump into any sewers, on the ground, or into any body of water.

14. TRANSPORT INFORMATION

ADG Not regulated for transport

Classification for SEA transport (IMO-IMDG):

Not regulated for transport Transport in bulk according to Annex I or II of MARPOL 73/78 and the IBC or IGC Code

Consult IMO regulations before transporting ocean bulk

Classification for AIR transport (IATA/ICAO):

Not regulated for transport

This information is not intended to convey all specific regulatory or operational requirements/information relating to this product. Transportation classifications may vary by container volume and may be influenced by regional or country variations in regulations. Additional transportation system information can be obtained through an authorized sales or customer service

Page 9: Material Safety Data Sheet - Ingersoll Rand Air ... · Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014 Page 3 of 9 Hazardous combustion products: During a fire,

Product name: Ingersoll Rand Techtrol Gold III Issue Date: 18.09.2014

Page 9 of 9

representative. It is the responsibility of the transporting organization to follow all applicable laws, regulations and rules relating to the transportation of the material.

15. REGULATORY INFORMATION

Label Classification and labeling have been performed according to regulations. Hazard symbol and Indication of danger HAZARDOUS SUBSTANCES CLASSIFICATION: Not classified as hazardous to health according to the criteria of the National Occupational Health and Safety Commission, Australia No poison schedule number allocated. Australia Inventory of Chemical Substances (AICS) All ingredients in this preparation are listed in the Australian Inventory of Chemical Substances, AICS

16. OTHER INFORMATION

Revision Identification Number: 101195756 / A142 / Issue Date: 18.09.2014 / Version: 2.0 Most recent revision(s) are noted by the bold, double bars in left-hand margin throughout this document.

INGERSOLL RAND urges each customer or recipient of this (M)SDS to study it

carefully and consult appropriate expertise, as necessary or appropriate, to become aware of and understand the data contained in this (M)SDS and any hazards associated with the product. The information herein is provided in good faith and believed to be accurate as of the effective date shown above. However, no warranty, express or implied, is given. Regulatory requirements are subject to change and may differ between various locations. It is the buyer’s/user’s responsibility to ensure that his activities comply with all federal, state, provincial or local laws. The information presented here pertains only to the product as shipped. Since conditions for use of the product are not under the control of the manufacturer, it is the buyer’s/user’s duty to determine the conditions necessary for the safe use of this product. Due to the proliferation of sources for information such as manufacturer-specific (M)SDSs, we are not and cannot be responsible for (M)SDSs obtained from any source other than ourselves. If you have obtained an (M)SDS from another source or if you are not sure that the (M)SDS you have is current, please contact us for the most current version.