LS totally enclosed three-phase asynchronous motors A2.1 General information Description of the LS aluminium three-phase motors Component Materials Remarks Finned housing Aluminium alloy - with bolt-on or cast foot, or without foot - 4 or 6 mounting holes for the foot housings - lifting rings for frame size 132 M, option in 132 S and 112 - optional earth terminal Stator Insulated low carbon magnetic steel laminations Electrolytic copper - the low carbon content guarantees long term stability of the characteristics - assembled laminated pack - semi-enclosed slots - insulation system class F Rotor Insulated low carbon magnetic steel laminations Aluminium (A5L) - inclined slots - squirrel cage pressure die cast in aluminium (or alloy for special applications) - mounted on the shaft by heat shrinking - dynamically balanced rotor, 1/2 key Shaft Steel - for frame size 132: • shaft end fitted with screw and washer • closed keyway - for frame size 132: • tapped centre hole • open keyway End shields Aluminium alloy - LS 56 - 63 - 71 front and rear - LS 80 - 90 rear Cast iron - LS 80 - 90 front (optional for LS 80 and 90 rear) - LS 100 to 315 front and rear Bearing and lubrication - ball bearings - 2RS type lubricated for life from LS 56 to LS 71 included - ZZ types lubricated for life from LS 80 to LS 180 included - semi-protected or open types for frame size 200 - regreasable open types from 225 upwards - rear preloaded bearings Labyrinth seals Lipseals Technopolymer or steel Synthetic rubber - lipseal or front jet deflector for all flange motors - lipseal, jet deflector or labyrinth seals for foot motor Fan Composite material or aluminium alloy - 2 directions of rotation: straight blades Fan cover Composite material or steel sheet metal - on request, fitted with a drip cover for operation in vertical position, shaft facing down Terminal box Composite material or aluminium alloy - IP 55 - rotatable, mounted opposite position to the feet - fitted with a 6 steel stud standard terminal board (brass as an optional extra) - terminal box delivered fitted with cable glands (optionally without cable glands) - 1 earth terminal in all terminal boxes Efficiency class IE1 Totally enclosed three-phase asynchronous motors, LS series, according IEC 60034, 60038, 60072 powers of 0.09 to 200 kW, frame sizes 56 to 315 mm. • Single speed: 2, 4, 6 and 8 poles; 230/400V or 400V Δ, 50Hz. • Two speed: 2/4, 4/6, 4/8, 6/8, 6/12 poles; centrifugal or general use; PAM, Dahlander or separate coils; 400V Υ or Δ, 50Hz. The selection tables for motors in this catalogue allow for: • Direct on line starting on the mains supplies 230V or 400V operating in: - delta connection (Δ) at 230V, - star connection (Υ) at 400V. • The star/delta start (Υ/Δ) on mains supply 400V with: - star connection (Υ) during initial starting, - delta connection (Δ) on 400V duty. Finition Assembled with protected screws. RAL 6000 finishing paint (green). Protection of the flange and shaft end against atmospheric corrosion. Individual anti-shock packaging. Conception multipositions en version B5/V1- B14/V18 version. Mains supply • Standard according to the IEC 60038: - 230/400 V +10% -10% at 50Hz. Standard construction suitable for the following power supplies: - 220/380V +5% -5% at 50Hz, - 230/400V +10% -10% at 50Hz, - 240/415V +5% -5% at 50Hz, - 265/460V +5% -5% at 60Hz. Voltages for the powers equal or greater than 3kW: - 380V Δ +5% -5% at 50Hz, - 400V Δ +10% -10% at 50Hz, - 415V Δ +5% -5% at 50Hz, - 460V Δ +5% -5% at 60Hz. Construction suitable for Υ/Δ starting.
52
Embed
LS totally enclosed three-phase asynchronous motorshasmak.com.tr/leroysomer/asenkron/4-LS-tri-en.pdf · LS totally enclosed three-phase asynchronous motors A2.4 IE1 Rated power Rated
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
LS totally enclosed three-phase asynchronous motors
A2.1
General information
Description of the LS aluminium three-phase motors
Component Materials Remarks
Finned housing Aluminium alloy - with bolt-on or cast foot, or without foot- 4 or 6 mounting holes for the foot housings- lifting rings for frame size 132 M, option in 132 S and 112- optional earth terminal
Stator Insulated low carbon magnetic steel laminationsElectrolytic copper
- the low carbon content guarantees long term stability of the characteristics- assembled laminated pack- semi-enclosed slots- insulation system class F
Rotor Insulated low carbon magnetic steel laminationsAluminium (A5L)
- inclined slots- squirrel cage pressure die cast in aluminium (or alloy for special applications)- mounted on the shaft by heat shrinking- dynamically balanced rotor, 1/2 key
Shaft Steel - for frame size 132: •shaftendfittedwithscrewandwasher •closedkeyway- for frame size 132: •tappedcentrehole •openkeyway
End shields Aluminium alloy - LS 56 - 63 - 71 front and rear- LS 80 - 90 rear
Cast iron - LS 80 - 90 front (optional for LS 80 and 90 rear)- LS 100 to 315 front and rear
Bearing and lubrication - ball bearings- 2RS type lubricated for life from LS 56 to LS 71 included- ZZ types lubricated for life from LS 80 to LS 180 included- semi-protected or open types for frame size 200- regreasable open types from 225 upwards- rear preloaded bearings
Labyrinth sealsLipseals
Technopolymer or steelSynthetic rubber
- lipseal or front jet deflector for all flange motors- lipseal, jet deflector or labyrinth seals for foot motor
Fan Composite material or aluminium alloy - 2 directions of rotation: straight blades
Fan cover Composite material or steel sheet metal -onrequest,fittedwithadripcoverforoperationinverticalposition,shaftfacingdown
Terminal box Composite materialor aluminium alloy
- IP 55- rotatable, mounted opposite position to the feet-fittedwitha6steelstudstandardterminalboard(brassasanoptionalextra)-terminalboxdeliveredfittedwithcableglands(optionallywithoutcableglands)- 1 earth terminal in all terminal boxes
Efficiency class IE1
Totally enclosed three-phase asynchronous motors, LS series, according IEC 60034, 60038, 60072 powers of 0.09 to 200 kW, frame sizes 56 to 315 mm.•Singlespeed:2,4,6and8poles;230/400Vor400VΔ, 50Hz.•Twospeed:2/4,4/6,4/8,6/8,6/12poles;centrifugalorgeneraluse;PAM,Dahlanderorseparatecoils;400VΥ or Δ, 50Hz.
The selection tables for motors in this catalogue allow for:•Directonlinestartingonthemainssupplies230Vor400Voperatingin:- delta connection (Δ)at230V,- star connection (Υ)at400V.•Thestar/deltastart(Υ/Δ) on mains supply 400Vwith:- star connection (Υ) during initial starting,- delta connection (Δ)on400Vduty.
FinitionAssembled with protected screws.RAL6000finishingpaint(green).
Protection of the flange and shaft end against atmospheric corrosion.Individual anti-shock packaging.ConceptionmultipositionsenversionB5/V1-B14/V18version.
Mains supply•StandardaccordingtotheIEC60038:-230/400V+10%-10%at50Hz.Standard construction suitable for the following power supplies:-220/380V+5%-5%at50Hz,-230/400V+10%-10%at50Hz,-240/415V+5%-5%at50Hz,-265/460V+5%-5%at60Hz.Voltagesforthepowersequalorgreaterthan3kW:-380VΔ +5%-5%at50Hz,-400VΔ +10%-10%at50Hz,-415VΔ +5%-5%at50Hz,-460VΔ +5%-5%at60Hz.Construction suitable for Υ/Δ starting.
LS totally enclosed three-phase asynchronous motors
A2.2
2
4
1 3
A
B D
Standardposition
Standardpositionat delivery(rotating)
Mounting positionsFoot mounted motors
IM 1001 (IM B3) IM 1051 (IM B6) IM 1061 (IM B7) IM 1071 (IM B8) IM 1011(IMV5)IM 1031(IMV6)
(FF) flange with plain holes mounted motors• Possible position IM 3001 (IM B5) up to 225 frame size inclusive
IM 3001 (IM B5) IM 3011(IMV1)IM 3031(IMV3)IM 2001 (IM B35) IM 2011(IMV15)IM 2031(IMV36)
(FT) flange with tapped holes mounted motors• Possible positions up to 132 frame size inclusive
IM 3601 (IM B14) IM 3611(IMV18)IM 3631(IMV19)IM 2101 (IM B34) IM 2111(IMV58)IM 2131(IMV69)
Terminal box positions Cable gland positions in relation to the motor shaft end in relation to the motor shaft end
A : standard 1 : standard * Position 2 not recommended and not feasible onstandardmotorfittedwithplainholeflange(FF)
*
LS totally enclosed three-phase asynchronous motors
A2.3
Designation/Codification
Adaptation possibilitiesLeroy-Somer offers, for use with the LS totally enclosed three-phase asynchronous motors, many options which meet the needs of highly diverse applications. They are described below and in the chapters relating to gearboxes and to speed variation.Forothervariantsoranyspecificadaptation,consultthetechnicalspecialistsatLeroy-Somer.
Feet mounted motor
(FF) plain holesflange mounted motor
(FT) tapped holesflange mounted motor
FLANGES MOUNTING METHODS OPTIONS
Forced ventilation
Tachometric dynamoTachometric alternator
Drip cover
Encoder
thermal protections:
PTO
PTF
CTP
2nd shaft end
Standard / non standard
(FT) tapped holes (FF) plain holes
F The LS three-motors may be associated to:
• gearboxes• electronic variable speed drive1
F The options:
• drip cover• anti-blocking cover• forced ventilation• thermal protection• aluminium terminal box• brass cable glands• cable glands of different dimensions• switch• cables output• stainless steel plate• second shaft end• non standard flanges• renforced sealing• plug-in connector
1. Conforming to regulations for use as indicated by the standard IEC 34-17.
The table above is an example.It enables the creation of the designation for the required product.The designation corresponds to a product code.The product codes that are present in the selection grids can be used directly. They simplify the ordering process.Thecodificationtableisincorporatedinthepricelistwiththedesignationslist.
F Codification example:LS three-phase asynchronous motor, 1500 min-1,18.5 kW IM 1001 (IM B3), 400 V Δ
Designation Code4P LS 180 MT 18.5 kWIM 1001 (IM B3) 400 V Δ EA4 18 302
F Codification example:Addition of a drip cover
Designation Code• drip cover MATP 1024
4P1500 min-1 LS 180 MT 18.5 kW
IM 1001(IM B3) 400 VΔ 50 Hz IP 55
Speedpolarity
Motortype
IEC 60072-1frame size
Housingdesignation and
builder index
Ratedpower
IEC 60034-7mounting position
Powersupplyvoltage
Powersupply
frequency
IEC 60034-5protection
LS totally enclosed three-phase asynchronous motors
A2.4
IE1
Ratedpower
Ratedspeed
Ratedtorque
Ratedcurrent
Powerfactor
Efficiency* IEC 60034-2-1; 2007
Startingcurrent/ Ratedcurrent
Startingtorque/ Ratedtorque
Maximumtorque/ Ratedtorque
Moment of inertia Weight Noise
PN NN MN IN (400V) Cos Phi η Id / In Md/Mn MM/Mn J IM B3 LP
Type kW min-1 Nm A 4/4 3/4 2/4 4/4 3/4 2/4 kg.m2 kg db(A)
LS 56 M 0.09 2860 0.3 0.44 0.55 0.45 0.4 54 45.2 37.1 5.0 5.3 5.4 0.00015 3.8 54
LS 56 M 0.12 2820 0.4 0.5 0.6 0.55 0.45 58.7 54 45.2 4.6 4.0 4.1 0.00015 3.8 54
LS 63 M 0.18 2790 0.6 0.52 0.75 0.65 0.55 67.4 66.9 59.3 5.0 3.3 2.9 0.00019 4.8 57
LS 63 M 0.25 2800 0.9 0.71 0.75 0.65 0.55 67.8 67.3 59.2 5.4 3.2 2.9 0.00025 6 57
LS 71 L 0.37 2800 1.3 0.98 0.8 0.7 0.6 68.4 67.6 63.9 5.2 3.3 3.9 0.00035 6.4 62
LS 71 L 0.55 2800 1.9 1.32 0.8 0.7 0.55 75.7 75.2 71.1 6.0 3.2 3.1 0.00045 7.3 62
LS 71 L 0.75 2780 2.6 1.7 0.85 0.75 0.65 74.6 75.8 73.1 6.0 3.3 2.9 0.0006 8.3 62
LS 80 L 0.75 2840 2.5 1.64 0.87 0.8 0.68 75.7 76.1 73.3 5.9 2.4 2.2 0.0007 8.2 61
LS 80 L 1.1 2837 3.7 2.4 0.84 0.77 0.65 77.3 78.3 76.4 5.8 2.7 2.4 0.0009 9.7 61
LS 80 L 1.5 2859 5.0 3.2 0.83 0.76 0.62 79.3 80 78.1 7.0 3.2 2.8 0.0011 11.3 61
LS 90 S 1.5 2870 5.0 3.4 0.81 0.72 0.58 80 79.5 75.9 8.0 3.9 4.0 0.0014 12 64
LS 90 L 1.8 2865 6.0 3.6 0.86 0.8 0.69 81.9 82.5 81.4 8.0 3.6 3.6 0.0017 14 64
LS 90 L 2.2 2862 7.3 4.3 0.88 0.83 0.73 82 83 82 7.7 3.7 3.3 0.0021 16 64
LS 100 L 3 2868 10.0 6.3 0.81 0.73 0.59 82.5 82.6 80.1 7.5 3.8 3.9 0.0022 20 66
LS 100 L 3.7 2850 12.5 8 0.85 0.76 0.62 82.7 82.2 77.2 8.6 0.0 0.0 0.0022 21 66
LS 112 M 4 2877 13.3 7.8 0.85 0.78 0.65 85 85.3 83.7 7.8 2.9 2.9 0.0029 24.4 66
● Temperature rise class F* This standard replaces the IEC 60034-2; 1996.** These motors do not reach the level of efficiency IE1.
Selection
PTO thermal protection -n/c IP 55 - 50 Hz - Class F - ΔT 80 K - 230 V Δ / 400 V Υ and 400 V Δ - S14
poles1500 min-1
LS totally enclosed three-phase asynchronous motors
A2.23
Selection example:Speed: 1500 min-1 - 4 polesPower: 4 kWMounting and position: IM 1001 (IM B3)Mains supply voltage: 230/400VThermal protection: PTO
Designation:4P LS 112 M 4 kW IM 1001 (IM B3)PTO 230/400 V
Code: EA0 00 159
SelectionPTO thermal protection -n/c
IP 55 - 50 Hz - Class F - ΔT 80 K - 230 V Δ / 400 V Υ and 400 V Δ - S1
Ratedpower
IM 1001Ratedpower
IM 1001
at 50 Hz in 230/400V
(IM B3)at 50 Hz in
400V∆ (IM B3)
PN PN
Type kW Code Qty Type kW Code Qty
LS 56 M 0.09 MA0 00 142 10 LS 132 S 5.5 EA000411 5
LS 63 M 0.12 MA0 00 143 10 LS 132 M 7.5 EA000412 5
LS 63 M1 0.12 MA0 00 144 5 LS 132 M 9 EA000413 5
LS 63 M 0.18 MA0 00 145 10 LS 160 MP 11 EA000414 5
LS 63 M1 0.18 MA0 00 146 5 LS 160 LR 15 EA000415 5
LS 63 M 0.25 MA0 00 208 5
LS 63 M1 0.25 MA0 00 147 5
LS 71 M 0.25 MA0 00 148 10
LS 71 M 0.37 MA0 00 149 10
LS 71 L 0.55 MA0 00 150 10
LS 80 L 0.55 MA0 00 151 10
LS 80 L 0.75 MA0 00 152 10
LS 80 L 0.9 MA0 00 153 2
LS 90 S 1.1 EA0 00 154 10
LS 90 L 1.5 EA0 00 155 10
LS 90 L 1.8 EA0 00 156 5
LS 100 L 2.2 EA0 00 157 10
LS 100 L 3 EA0 00 158 5
LS 112 M 4 EA0 00 159 10
LS 132 S 5.5 EA0 00 160 5
LS 132 M 7.5 EA0 00 161 10
LS 132 M 9 EA0 00 162 5
LS 160 MP 11 EA0 00 163 5
LS 160 LR 15 EA0 00 164 5
LS 180 MT 18.5 EA0 00 165 1
LS 180 LR 22 EA0 00 166 1
LS 200 LT 30 EA0 00 167 1
LS 225 ST 37 EA0 00 168 1
LS 225 MR 45 EA0 00 169 1
LS 250 ME 55 EA0 00 170 1
LS 280 SC 75 EA0 00 171 1
LS 280 MD 90 -
LS 315 SN 110 -
LS 315 MP 132 -
LS 315 MR 160 -
1. Flange or foot motor (or foot and flange) with shaft end different fromthe standard (D: 14 j6 - E: 30 mm).
4poles1500 min-1
LS totally enclosed three-phase asynchronous motors
A2.24
Selection
Non standard flange IP 55 - 50 Hz - Class F - ΔT 80 K - 230 V Δ / 400 V Υ - S12
poles3000 min-1
Non standard flange motors:asanoption,themotorsmaybefittedwithflangessmallerthanthe standard flanges1. Consequently, the dimensions of the flanges M, N and P correspond to the dimensions of the standard flange for the next frame size down.1. See page A2.44 for flange dimensions.
IE1
Ratedpower
Ratedspeed
Ratedtorque
Ratedcurrent
Powerfactor
Efficiency* IEC 60034-2-1; 2007
Starting current/ Rated current
Starting torque/ Ratedtorque
Maximum torque/ Rated torque
Moment of inertia Weight Noise
PN NN MN IN (400V) Cos Phi η Id / In Md/Mn MM/Mn J IM B3 LP
Type kW min-1 Nm A 4/4 3/4 2/4 4/4 3/4 2/4 kg.m2 kg db(A)
LS 56 M 0.09 2860 0.3 0.44 0.55 0.45 0.4 54 45.2 37.1 5.0 5.3 5.4 0.00015 3.8 54
LS 56 M 0.12 2820 0.4 0.5 0.6 0.55 0.45 58.7 54 45.2 4.6 4.0 4.1 0.00015 3.8 54
LS 63 M 0.18 2790 0.6 0.52 0.75 0.65 0.55 67.4 66.9 59.3 5.0 3.3 2.9 0.00019 4.8 57
LS 63 M 0.25 2800 0.9 0.71 0.75 0.65 0.55 67.8 67.3 59.2 5.4 3.2 2.9 0.00025 6 57
LS 71 L 0.37 2800 1.3 0.98 0.8 0.7 0.6 68.4 67.6 63.9 5.2 3.3 3.9 0.00035 6.4 62
LS 71 L 0.55 2800 1.9 1.32 0.8 0.7 0.55 75.7 75.2 71.1 6.0 3.2 3.1 0.00045 7.3 62
LS 71 L 0.75 2780 2.6 1.7 0.85 0.75 0.65 74.6 75.8 73.1 6.0 3.3 2.9 0.0006 8.3 62
LS 80 L 0.75 2840 2.5 1.64 0.87 0.8 0.68 75.7 76.1 73.3 5.9 2.4 2.2 0.0007 8.2 61
LS 80 L 1.1 2837 3.7 2.4 0.84 0.77 0.65 77.3 78.3 76.4 5.8 2.7 2.4 0.0009 9.7 61
LS 80 L 1.5 2859 5.0 3.2 0.83 0.76 0.62 79.3 80 78.1 7.0 3.2 2.8 0.0011 11.3 61
LS 90 S 1.5 2870 5.0 3.4 0.81 0.72 0.58 80 79.5 75.9 8.0 3.9 4.0 0.0014 12 64
LS 90 L 1.8 2865 6.0 3.6 0.86 0.8 0.69 81.9 82.5 81.4 8.0 3.6 3.6 0.0017 14 64
LS 90 L 2.2 2862 7.3 4.3 0.88 0.83 0.73 82 83 82 7.7 3.7 3.3 0.0021 16 64
LS 100 L 3 2868 10.0 6.3 0.81 0.73 0.59 82.5 82.6 80.1 7.5 3.8 3.9 0.0022 20 66
LS 100 L 3.7 2850 12.5 8 0.85 0.76 0.62 82.7 82.2 77.2 8.6 0.0 0.0 0.0022 21 66
LS 112 M 4 2877 13.3 7.8 0.85 0.78 0.65 85 85.3 83.7 7.8 2.9 2.9 0.0029 24.4 66
● Temperature rise class F* This standard replaces the IEC 60034-2; 1996.
LS totally enclosed three-phase asynchronous motors
A2.25
Selection example:Speed: 3000 min-1 - 2 polesPower: 1.5 kWMounting and position: IM 2001 (IM B35) FF130Mains supply voltage: 230/400V
Designation:2P LS 90 S 1.5 kW IM 2001 (IM B35)FF 130 230/400 V
Code: EA2 15 2DF
Selection
Non standard flange IP 55 - 50 Hz - Class F - ΔT 80 K - 230 V Δ / 400 V Υ - S1
Non standard flange motors:asanoption,themotorsmaybefittedwithflangessmallerthanthe standard flanges1. Consequently, the dimensions of the flanges M, N and P correspond to the dimensions of the standard flange for the next frame size down.
2poles3000 min-1
1. See page A2.44 for flange dimensions.
Ratedpower
IM 3001 IM 2001 IM 3601 IM 2101
at 50 Hz (IM B5) (IM B35) (IM B14) (IM B34)
PN
Type kW Code Qty Code Qty Code Qty Code Qty
LS 71 L 0.37 MA2 37 L21 5 - MA2 37 T23 5 MA2 37 TC3 5
LS 71 L 0.55 MA2 55 L21 5 - MA2 55 T23 5 MA2 55 TC3 5
LS 80 L 0.75 MA2 75 13F 5 MA2751DF 5 MA2 75 13H 5 MA2751DH 5
LS 80 L 1.1 EA2 11 23F 5 EA2112DF 5 EA2 11 13H 5 EA2112DH 5
LS 90 S 1.5 EA2 15 23F 5 EA2152DF 5 EA2 15 23H 5 EA2152DH 5
LS 90 L 2.2 EA2 22 22B 5 EA2 22 2CB 5 EA22222D 5 EA2222CD 5
LS 100 L 3 EA23020D 5 EA2302AD 5 EA2 30 20F 5 EA2 30 2AF 5
LS 112 M 4 EA24020D 5 EA2402AD 5 EA2 40 20F 5 EA2 40 2AF 5
LS 132 S 5.5 EA2 55 20J 2 EA2 55 2AJ 2 EA2 55 21B 2 EA2 55 2BB 2
LS 132 S 7.5 EA27520D 2 EA2752AD 2 EA2 75 20F 2 EA2 75 2AF 2
LS 132 M 9 EA29020D 2 EA2902AD 2 EA2 90 20F 2 EA2 90 2AF 2
LS 132 M 11 EA2 11 34C 2 EA2 11 3EC 2 - -
LS 160 MP 11 EA21130D 2 EA2113AD 2
LS 160 MP 15 EA21530D 2 EA2153AD 2
LS totally enclosed three-phase asynchronous motors
A2.26
Selection
Non standard flange IP 55 - 50 Hz - Class F - ΔT 80 K - 230 V Δ / 400 V Υ - S14
poles1500 min-1
Non standard flange motors:asanoption,themotorsmaybefittedwithflangessmallerthanthe standard flanges1. Consequently, the dimensions of the flanges M, N and P correspond to the dimensions of the standard flange for the next frame size down.1. See page A2.44 for flange dimensions.
IE1
Ratedpower
Ratedspeed
Ratedtorque
Ratedcurrent
Powerfactor
Efficiency* IEC 60034-2-1; 2007
Starting current/ Rated current
Starting torque/ Ratedtorque
Maximum torque/ Rated torque
Moment of inertia Weight Noise
PN NN MN IN (400V) Cos Phi η Id / In Md/Mn MM/Mn J IM B3 LP
Type kW min-1 Nm A 4/4 3/4 2/4 4/4 3/4 2/4 kg.m2 kg db(A)
LS 56 M 0.06 1380 0.4 0.29 0.76 0.69 0.62 41.8 37.1 29.7 2.8 2.4 2.5 0.00025 4 47
LS 56 M 0.09 1400 0.6 0.39 0.6 0.52 0.42 55.2 49.6 42.8 3.2 2.8 2.8 0.00025 4 47
LS 63 M 0.12 1380 0.8 0.44 0.7 0.58 0.47 56.1 53.9 46.8 3.2 2.4 2.3 0.00035 4.8 49
LS 63 M 0.18 1390 1.2 0.64 0.65 0.55 0.44 61.6 58 51.3 3.7 2.6 2.6 0.00048 5 49
LS 71 M 0.25 1425 1.7 0.8 0.65 0.55 0.44 69.4 66.8 59.8 4.6 2.7 2.9 0.00068 6.4 49
LS 71 M 0.37 1420 2.5 1.06 0.7 0.59 0.47 72.1 71.7 66.4 4.9 2.4 2.8 0.00085 7.3 49
LS 71 L 0.55 1400 3.8 1.62 0.7 0.62 0.49 70.4 70 65.1 4.8 2.3 2.5 0.0011 8.3 49
LS 80 L 0.55 1410 3.7 1.42 0.76 0.68 0.55 73.2 69.1 62.1 4.5 2.0 2.3 0.0013 8.2 47
LS 80 L 0.75 1400 5.1 2.01 0.77 0.71 0.59 72.1 72.8 70.1 4.5 2.0 2.2 0.0018 9.3 47
LS 80 L 0.9 1425 6.0 2.44 0.73 0.67 0.54 73.2 72.9 70.3 5.8 3.0 3.0 0.0024 10.9 47
LS 90 S 1.1 1429 7.4 2.5 0.84 0.77 0.64 76.7 78.2 76.6 4.8 1.6 2.0 0.0026 11.5 48
LS 90 L 1.5 1428 10.0 3.4 0.82 0.74 0.6 79.3 79.9 77.5 5.3 1.8 2.3 0.0032 13.5 48
LS 90 L 1.8 1438 12.0 4 0.82 0.75 0.61 79.4 80 77.6 6 2.1 3.2 0.0037 15.2 48
LS 100 L 2.2 1436 14.6 4.8 0.81 0.73 0.59 80.3 81.2 79.3 5.9 2.1 2.5 0.0043 20 48
LS 100 L 3 1437 19.9 6.5 0.81 0.72 0.59 82.8 83.4 81.8 6 2.5 2.8 0.0055 22.5 48
● Temperature rise class F* This standard replaces the IEC 60034-2; 1996.** These motors do not reach the level of efficiency IE1.
LS totally enclosed three-phase asynchronous motors
A2.27
Selection example:Vitesse: 1500 min-1 - 4 polesPower: 2.2 kWMounting and position: IM 2101 (IM B34) FF115Mains supply voltage: 230/400V
Designation:4P LS 100 L 2.2 kW IM 2101 (IM B34)FF 115 230/400 V
Code: EA4 22 2BB
Selection
Non standard flange IP 55 - 50 Hz - Class F - ΔT 80 K - 230 V Δ / 400 V Υ - S1
Non standard flange motors:asanoption,themotorsmaybefittedwithflangessmallerthanthe standard flanges1. Consequently, the dimensions of the flanges M, N and P correspond to the dimensions of the standard flange for the next frame size down.
4poles1500 min-1
1. See page A2.44 for flange dimensions.
Rated power IM 3001 IM 2001 IM 3601 IM 2101
at 50 Hz (IM B5) (IM B35) (IM B14) (IM B34)
PN
Type kW Code Qty Code Qty Code Qty Code Qty
LS 71 M 0.25 MA4 25 12B 5 - MA4 25 12D 5 -
LS 71 M 0.37 MA4 37 12B 5 - MA4 37 12D 5 -
LS 71 L 0.55 MA4 55 13D 5 - - -
LS 80 L 0.55 MA4 55 11F 2 MA4 55 1BF 2 MA4 55 11H 2 MA4 55 1BH 2
LS 80 L 0.75 MA4 75 12B 2 MA4 75 1CB 2 MA47512D 2 MA4751CD 2
LS 90 S 1.1 EA4 11 22B 2 EA4 11 2CB 2 EA41122D 2 EA4112CD 2
LS 90 L 1.5 EA4 15 20J 2 EA4 15 2AJ 2 EA4 15 21B 2 EA4 15 2BB 2
LS 100 L 2.2 EA4 22 20J 2 EA4 22 2AJ 2 EA4 22 21B 2 EA4 22 2BB 2
LS 100 L 3 EA4 30 20J 2 EA4 30 2AJ 2 EA4 30 21B 2 EA4 30 2BB 2
LS 112 M 4 MA44020D 2 MA4402AD 2 MA4 40 20F 2 MA4 40 2AF 2
LS 132 S 5.5 EA4 55 20J 1 EA4 55 2AJ 1 EA4 55 21B 1 EA4 55 2BB 1
LS 132 M 7.5 EA4 75 20J 1 EA4 75 2AJ 1 EA4 75 21B 1 EA4 75 2BB 1
LS 132 M 9 EA49020D 1 EA4902AD 1 EA4 90 20F 1 EA4 90 2AF 1
LS totally enclosed three-phase asynchronous motors
A2.28
Selection
Non standard flange IP 55 - 50 Hz - Class F - ΔT 80 K - 230 V Δ / 400 V Υ - S1
6poles1000 min-1
6poles1000 min-1
6poles1000 min-1
6poles1000 min-1
Non standard flange motors:asanoption,themotorsmaybefittedwithflangessmallerthanthe standard flanges1. Consequently, the dimensions of the flanges M, N and P correspond to the dimensions of the standard flange for the next frame size down.1. See page A2.44 for flange dimensions.
IE1
Ratedpower
Ratedspeed
Ratedtorque
Ratedcurrent
Powerfactor
Efficiency* IEC 60034-2-1; 2007
Starting current/ Rated current
Starting torque/ Ratedtorque
Maximum torque/ Rated torque
Moment of inertia Weight Noise
PN NN MN IN (400V) Cos Phi η Id / In Md/Mn MM/Mn J IM B3 LP
Type kW min-1 Nm A 4/4 3/4 2/4 4/4 3/4 2/4 kg.m2 kg db(A)
LS 56 M 0.045 860 0.5 0.29 0.66 0.59 0.52 34 31.5 25.3 2 1.7 1.7 0.00025 4 54
LS 56 M 0.06 850 0.7 0.39 0.67 0.6 0.53 33.4 30.9 25 2 1.7 1.7 0.00025 4 54
LS 63 M 0.09 860 1.0 0.46 0.8 0.7 0.63 35 32 26 2.1 1.6 1.6 0.0006 5.5 48
LS 71 M 0.12 950 1.2 0.75 0.51 0.44 0.38 45.6 40.5 32 3 2.4 3.0 0.0007 6.5 52
LS 71 M 0.18 945 1.8 0.95 0.52 0.46 0.38 52.8 48.8 40.7 3.3 2.3 2.9 0.0011 7.6 52
LS 71 L 0.25 915 2.6 1.15 0.6 0.52 0.43 51.9 49.6 42.2 3.1 2.0 2.2 0.0013 7.9 52
LS 80 L 0.25 955 2.5 0.85 0.67 0.64 0.48 62.8 62.7 56 3.9 1.6 1.8 0.0024 8.4 41
LS 80 L 0.37 950 3.7 1.1 0.72 0.67 0.57 65.8 59.7 59 4.3 1.7 2.2 0.0032 9.7 41
LS 80 L 0.55 950 5.5 1.8 0.64 0.6 0.47 68 63 55 4.9 2.1 2.6 0.0042 11 41
LS 90 S 0.75 930 7.7 2.1 0.77 0.66 0.54 70.5 69.3 63.5 4.7 2.4 2.6 0.0039 13.5 51
* This standard replaces the IEC 60034-2; 1996.** These motors do not reach the level of efficiency IE1.
LS totally enclosed three-phase asynchronous motors
A2.29
Selection
Non standard flange motors:asanoption,themotorsmaybefittedwithflangessmallerthanthe standard flanges1. Consequently, the dimensions of the flanges M, N and P correspond to the dimensions of the standard flange for the next frame size down.
Non standard flange IP 55 - 50 Hz - Class F - ΔT 80 K - 230 V Δ / 400 V Υ - S1
* This standard replaces the IEC 60034-2; 1996.** These motors do not reach the level of efficiency IE1.
LS totally enclosed three-phase asynchronous motors
A2.30
Selection
Non standard flange IP 55 - 50 Hz - Class F - ΔT 80 K - 400 V Δ - S1
Non standard flange motors:asanoption,themotorsmaybefittedwithflangessmallerthanthe standard flanges1. Consequently, the dimensions of the flanges M, N and P correspond to the dimensions of the standard flange for the next frame size down.
2poles3000 min-1
1. See page A2.44 for flange dimensions.
IE1
Ratedpower
Ratedspeed
Ratedtorque
Ratedcurrent
Powerfactor
Efficiency* IEC 60034-2-1; 2007
Starting current/ Rated current
Starting torque/ Ratedtorque
Maximum torque/ Rated torque
Moment of inertia Weight Noise
PN NN MN IN (400V) Cos Phi η Id / In Md/Mn MM/Mn J IM B3 LP
Type kW min-1 Nm A 4/4 3/4 2/4 4/4 3/4 2/4 kg.m2 kg db(A)
LS 56 M 0.09 2860 0.3 0.44 0.55 0.45 0.4 54 45.2 37.1 5.0 5.3 5.4 0.00015 3.8 54
LS 56 M 0.12 2820 0.4 0.5 0.6 0.55 0.45 58.7 54 45.2 4.6 4.0 4.1 0.00015 3.8 54
LS 63 M 0.18 2790 0.6 0.52 0.75 0.65 0.55 67.4 66.9 59.3 5.0 3.3 2.9 0.00019 4.8 57
LS 63 M 0.25 2800 0.9 0.71 0.75 0.65 0.55 67.8 67.3 59.2 5.4 3.2 2.9 0.00025 6 57
LS 71 L 0.37 2800 1.3 0.98 0.8 0.7 0.6 68.4 67.6 63.9 5.2 3.3 3.9 0.00035 6.4 62
LS 71 L 0.55 2800 1.9 1.32 0.8 0.7 0.55 75.7 75.2 71.1 6.0 3.2 3.1 0.00045 7.3 62
LS 71 L 0.75 2780 2.6 1.7 0.85 0.75 0.65 74.6 75.8 73.1 6.0 3.3 2.9 0.0006 8.3 62
LS 80 L 0.75 2840 2.5 1.64 0.87 0.8 0.68 75.7 76.1 73.3 5.9 2.4 2.2 0.0007 8.2 61
LS 80 L 1.1 2837 3.7 2.4 0.84 0.77 0.65 77.3 78.3 76.4 5.8 2.7 2.4 0.0009 9.7 61
LS 80 L 1.5 2859 5.0 3.2 0.83 0.76 0.62 79.3 80 78.1 7.0 3.2 2.8 0.0011 11.3 61
LS 90 S 1.5 2870 5.0 3.4 0.81 0.72 0.58 80 79.5 75.9 8.0 3.9 4.0 0.0014 12 64
LS 90 L 1.8 2865 6.0 3.6 0.86 0.8 0.69 81.9 82.5 81.4 8.0 3.6 3.6 0.0017 14 64
LS 90 L 2.2 2862 7.3 4.3 0.88 0.83 0.73 82 83 82 7.7 3.7 3.3 0.0021 16 64
LS 100 L 3 2868 10.0 6.3 0.81 0.73 0.59 82.5 82.6 80.1 7.5 3.8 3.9 0.0022 20 66
LS 100 L 3.7 2850 12.5 8 0.85 0.76 0.62 82.7 82.2 77.2 8.6 0.0 0.0 0.0022 21 66
LS 112 M 4 2877 13.3 7.8 0.85 0.78 0.65 85 85.3 83.7 7.8 2.9 2.9 0.0029 24.4 66
● Temperature rise class F* This standard replaces the IEC 60034-2; 1996.
LS totally enclosed three-phase asynchronous motors
A2.31
Selection example:Speed: 3000 min-1 - 2 polesPower: 7.5 kWMounting and position: IM 3001 (IM B5) FF215Mains supply voltage: 400V
Designation:2P LS 132 S 7.5 kW IM 3001 (IM B5)FF 215 400 V
Code: EA2 75 20E
Selection
Non standard flange IP 55 - 50 Hz - Class F - ΔT 80 K - 400 V Δ - S1
Non standard flange motors:asanoption,themotorsmaybefittedwithflangessmallerthanthe standard flanges1. Consequently, the dimensions of the flanges M, N and P correspond to the dimensions of the standard flange for the next frame size down.
2poles3000 min-1
1. See page A2.44 for flange dimensions.
Ratedpower
IM 3001 IM 2001 IM 3601 IM 2101
at 50 Hz (IM B5) (IM B35) (IM B14) (IM B34)
PN
Type kW Code Qty Code Qty Code Qty Code Qty
LS 100 L 3 EA2 30 20E 5 EA2 30 2AE 5 EA2 30 20G 5 EA2 30 2AG 5
LS 112 M 4 EA2 40 20E 5 EA2 40 2AE 5 EA2 40 20G 5 EA2 40 2AG 5
LS 112 MG 5.5 EA2 55 20E 5 EA2 55 2AE 5 EA2 55 20G 5 EA2 55 2AG 5
LS 132 S 5.5 EA2 55 21A 2 EA2 55 2BA 2 EA2 55 21C 2 EA2 55 2B2 2
LS 132 S 7.5 EA2 75 20E 2 EA2 75 2AE 2 EA2 75 20G 2 EA2 75 2AG 2
LS 132 M 9 EA2 90 20E 2 EA2 90 2AE 2 EA2 90 20G 2 EA2 90 2AG 2
LS 132 M 11 EA2 11 50A 2 EA2115AD 2 - -
LS 160 MP 11 EA2 11 30A 2 EA2 11 30B 2
LS 160 MP 15 EA2 15 30A 2 EA2 15 30B 2
LS totally enclosed three-phase asynchronous motors
A2.32
Selection
Non standard flange IP 55 - 50 Hz - Class F - ΔT 80 K - 400 V Δ - S1
Non standard flange motors:asanoption,themotorsmaybefittedwithflangessmallerthanthe standard flanges1. Consequently, the dimensions of the flanges M, N and P correspond to the dimensions of the standard flange for the next frame size down.
4poles1500 min-1
1. See page A2.44 for flange dimensions.
IE1
Ratedpower
Ratedspeed
Ratedtorque
Ratedcurrent
Powerfactor
Efficiency* IEC 60034-2-1; 2007
Starting current/ Rated current
Starting torque/ Ratedtorque
Maximum torque/ Rated torque
Moment of inertia Weight Noise
PN NN MN IN (400V) Cos Phi η Id / In Md/Mn MM/Mn J IM B3 LP
Type kW min-1 Nm A 4/4 3/4 2/4 4/4 3/4 2/4 kg.m2 kg db(A)
LS 56 M 0.06 1380 0.4 0.29 0.76 0.69 0.62 41.8 37.1 29.7 2.8 2.4 2.5 0.00025 4 47
LS 56 M 0.09 1400 0.6 0.39 0.6 0.52 0.42 55.2 49.6 42.8 3.2 2.8 2.8 0.00025 4 47
LS 63 M 0.12 1380 0.8 0.44 0.7 0.58 0.47 56.1 53.9 46.8 3.2 2.4 2.3 0.00035 4.8 49
LS 63 M 0.18 1390 1.2 0.64 0.65 0.55 0.44 61.6 58 51.3 3.7 2.6 2.6 0.00048 5 49
LS 71 M 0.25 1425 1.7 0.8 0.65 0.55 0.44 69.4 66.8 59.8 4.6 2.7 2.9 0.00068 6.4 49
LS 71 M 0.37 1420 2.5 1.06 0.7 0.59 0.47 72.1 71.7 66.4 4.9 2.4 2.8 0.00085 7.3 49
LS 71 L 0.55 1400 3.8 1.62 0.7 0.62 0.49 70.4 70 65.1 4.8 2.3 2.5 0.0011 8.3 49
LS 80 L 0.55 1410 3.7 1.42 0.76 0.68 0.55 73.2 69.1 62.1 4.5 2.0 2.3 0.0013 8.2 47
LS 80 L 0.75 1400 5.1 2.01 0.77 0.71 0.59 72.1 72.8 70.1 4.5 2.0 2.2 0.0018 9.3 47
LS 80 L 0.9 1425 6.0 2.44 0.73 0.67 0.54 73.2 72.9 70.3 5.8 3.0 3.0 0.0024 10.9 47
LS 90 S 1.1 1429 7.4 2.5 0.84 0.77 0.64 76.7 78.2 76.6 4.8 1.6 2.0 0.0026 11.5 48
LS 90 L 1.5 1428 10.0 3.4 0.82 0.74 0.6 79.3 79.9 77.5 5.3 1.8 2.3 0.0032 13.5 48
LS 90 L 1.8 1438 12.0 4 0.82 0.75 0.61 79.4 80 77.6 6 2.1 3.2 0.0037 15.2 48
LS 100 L 2.2 1436 14.6 4.8 0.81 0.73 0.59 80.3 81.2 79.3 5.9 2.1 2.5 0.0043 20 48
LS 100 L 3 1437 19.9 6.5 0.81 0.72 0.59 82.8 83.4 81.8 6 2.5 2.8 0.0055 22.5 48
● Temperature rise class F* This standard replaces the IEC 60034-2; 1996.** These motors do not reach the level of efficiency IE1.
LS totally enclosed three-phase asynchronous motors
A2.33
Selection example:Speed: 1500 min-1 - 4 polesPower: 7.5 kWMounting and position: IM 2001 (IM B35) FF215Mains supply voltage: 400V
Designation:4P LS 132 M 7.5 kW IM 2001 (IM B35)FF 215 400 V
Code: EA4 75 2BA
Selection
Non standard flange IP 55 - 50 Hz - Class F - ΔT 80 K - 400 V Δ - S1
Non standard flange motors:asanoption,themotorsmaybefittedwithflangessmallerthanthe standard flanges1. Consequently, the dimensions of the flanges M, N and P correspond to the dimensions of the standard flange for the next frame size down.
4poles1500 min-1
1. See page A2.44 for flange dimensions.
Ratedpower
IM 3001 IM 2001 IM 3601 IM 2101
at 50 Hz (IM B5) (IM B35) (IM B14) (IM B34)
PN
Type kW Code Qty Code Qty Code Qty Code Qty
LS 100 L 3 EA4 30 21A 5 EA4 30 2GA 5 EA4 30 21C 5 EA4 30 2BC 5
LS 112 M 4 MA4 40 20E 5 MA4 40 2AE 5 MA4 40 20G 5 MA4 40 2AG 5
LS 132 S 5.5 EA4 55 21A 2 EA4 55 2BA 2 EA4 55 21G 2 EA4 55 2BC 2
LS 132 M 7.5 EA4 75 21A 2 EA4 75 2BA 2 EA4 75 21G 2 EA4 75 2BC 2
LS 132 M 9 EA4 90 20E 2 EA4 90 2AE 2 EA4 90 21G 2 EA4 90 2AG 2
LS multi-speed closed three-phase asynchronous motors
A2.34
The motors are for use with quadratic resistive torque machines (centrifugal machines).The high speed power (GV) is that of the standard motor having the same speed in the same frame size (from 80 to 315 included).The motors connection is provided only for one power supply voltage (Dahlander connection) and it does not allow star delta starting.
Rated power
at 50 HzRatedspeed
Ratedcurrent
Powerfactor
EfficiencyIEC 60034-2;
1996Starting torque /
Rated torque Weight
TypePNkW
NNmin–1
IN (400 V)A
Cos ϕ100%
η100%
ID / IN IM B3kg
LS 71 M GV1
PV20.370.075 8.3
LS 71 M GVPV
0.550.11
28101420
1.40.4
0.90.7
6973
4.74.6 8.3
LS 80 L GVPV
1.10.25
28101420
2.50.66
0.870.78
7270
5.24.6 10.9
LS 90 S GVPV
1.50.35
28501440
3.80.9
0.820.77
7075
5.15.7 14
LS 90 L GVPV
2.20.6
28401450
4.81.5
0.90.82
7471
5.85.2 15.2
LS 100 L GVPV
30.8
29201450
6.61.7
0.840.82
7883
6.85.8 24.5
LS 112 MU GVPV
4.51.3
29101460
9.93.1
0.830.75
7980
6.96 37
LS 132 SM GVPV
61.6
28951440
13.23.7
0.840.79
7879
6.25.5 50
LS 132 M GVPV
92.5
29201440
18.65.6
0.850.79
8281
7.36.2 60
LS 160 M GVPV
13.53.3
29201465
266.3
0.870.85
86.388.7
6.46.4 85
LS 160 L GVPV
194.5
29251465
35.38.4
0.890.88
87.487.5
7.36.7 100
LS 180 LU GVPV
248
29351455
44.515.2
0.890.87
87.587.5
7.55 165
LS 200 L GVPV
3111
29551465
55.920.2
0.910.89
8888.5
85.2 205
LS 200 LU GVPV
4014
29551465
7125.1
0.900.88
9091.5
85.2 235
LS 225 MG GVPV
5017
29701476
8730.9
0.900.85
9292.2
8.85.5 320
LS 250 ME GVPV
5920
29701476
10336.4
0.900.85
9292.2
8.85.5 340
LS 250 ME GVPV
7024
29701476
12243.7
0.900.85
9292.2
8.85.5 380
LS 280 MD GVPV
8530
29701476
14854.6
0.900.85
9292.2
8.85.5 450
LS 315 MR GVPV
10035
29751485
16860.9
0.920.88
93.394.3
8.55.5 8251. GV : High speed. 2. PV : Low speed.
Use: centrifugal machines
1 winding (PAM)1
IP 55 - 50 Hz - Class F - ΔT 80 K - 400 V - S1 4 - 6 Poles1500-1000 min-1
Rated power
at 50 HzRatedspeed
Ratedcurrent
Powerfactor
EfficiencyIEC 60034-2;
1996Starting torque /
Rated torque Weight
TypePNkW
NNmin–1
IN (400 V)A
Cos ϕ100%
η100%
ID / IN IM B3kg
LS 80 L GV2
PV30.750.25
1400905
1.80.9
0.870.88
6746
3.82.1 10.9
LS 90 SL GVPV
1.10.37
1420940
2.62.2
0.790.64
7757
63.3 14
LS 90 L GVPV
1.50.55
1425940
3.61.5
0.80.63
7857
6.13.3 15.2
LS 100 L GVPV
2.20.75
1400940
4.82.3
0.860.75
7763
6.84.2 24.5
LS 100 L GVPV
31.1
1410940
6.73.2
0.840.76
7765
6.64.4 24.5
LS 112 MU GVPV
41.5
1450965
94.7
0.780.70
8267
73.6 37
LS 132 SM GVPV
5.51.8
1460970
11.77.4
0.820.70
8470
6.44.4 55
LS 132 M GVPV
7.52.5
1445975
15.56.2
0.840.62
8369
74 60
1. 2 separate windings, see pages A2.30 and A2.31. 2. GV: High speed. 3. PV: Low speed.
The motors are for use with quadratic resistive torque machines (centrifugal machines).The high speed power (GV) is that of the standard motor having the same speed in the same frame size (from 80 to 315 included).The motors connection is provided only for one power supply voltage (Dahlander connection) and it does not allow star delta starting.
The motors are for use with quadratic resistive torque machines (centrifugal machines).The high speed power (GV) is that of the standard motor having the same speed in the same frame size (from 80 to 315 included).The motors connection is provided only for one power supply voltage (Dahlander connection) and it does not allow star delta starting.
4 - 6 Poles1500-1000 min-1
Rated power
at 50 HzRatedspeed
Ratedcurrent
Powerfactor
EfficiencyIEC 60034-2;
1996Starting torque /
Rated torque Weight
TypePNkW
NNmin–1
IN (400 V)A
Cos ϕ100%
η100%
ID / IN IM B3kg
LS 71 L GV2
PV30.250.09
1430960
0.750.55
0.780.64
6640
3.82.3 8.3
LS 80 L GVPV
0.70.2
1435945
2.11.05
0.730.72
6740
4.52.5 10.9
LS 90 S GVPV
0.850.25
1430930
2.20.85
0.780.79
7055
5.53.5 14
LS 90 L GVPV
1.40.5
1425925
3.51.4
0.790.80
7361
63.6 15.2
LS 100 L GVPV
2.40.75
1425940
5.72.1
0.820.75
7566
5.64.3 24.5
LS 112 MG GVPV
3.41.1
1460965
8.73.4
0.720.75
7864
6.94 37
LS 132 SM GVPV
41.2
1450970
8.93.2
0.790.68
8280
5.84.5 50
LS 132 M GVPV
6.31.9
1445970
13.25
0.820.71
8475
5.95.2 60
LS 160 M GVPV
93
1465975
18.87.8
0.810.75
85.278.6
75.2 85
LS 160 M GVPV
113.7
1465975
22.69.3
0.820.76
85.778.8
7.45.5 85
LS 160 L GVPV
134.3
1465970
25.610.5
0.840.74
87.374.9
7.85.5 100
LS 160 LU GVPV
155
1465970
29.312.1
0.840.74
87.977.8
7.55.1 110
LS 180 L GVPV
18.56.5
1460980
34.114.8
0.880.78
8981
5.55 135
LS 180 LU GVPV
227.5
1470980
41.516.6
0.860.80
89.081.5
6.84.8 165
LS 200 L GVPV
258.5
1475985
46.919.3
0.850.77
90.582.5
6.44.8 205
LS 200 LU GVPV
309
1475985
56.020.8
0.850.74
91.084.5
65.3 235
LS 225 SR GVPV
3411
1475985
6425.9
0.840.73
91.684.0
6.35.1 235
LS 250 ME GVPV
4214
1480985
77.731.8
0.850.75
91.887
6.55.1 320
LS 250 MF GVPV
5219
1480985
9643.2
0.850.73
9287
6.55.1 320
LS 280 SK GVPV
7528
1485985
13556.3
0.860.80
93.589.7
7.76.6 720
LS 280 MK GVPV
9033
1485985
16166.2
0.860.80
93.790.0
7.76.9 720
LS 315 SP GVPV
11037
1485985
19974
0.850.80
93.990.1
86.9 825
LS 315 MR GVPV
13244
1485985
24488
0.830.80
94.090.2
9.27.1 825
1. LS 80 to LS 132, 1 winding (PAM), see pages A2.28 and A2.29.2. GV: High speed.3. PV: Low speed.
LS multi-speed closed three-phase asynchronous motors
A2.37
Selection example:Speed: 1500-1000 min-1-4/6 poles
Power: 18.5/6.5 kWMounting and position: IM 1001 (IM B3)Mains supply voltage: 400V
Designation:4/6 P LS 180 L 18.5/6.5 kW IM 1001 (IM B3) 400 V
1. LS 80 to LS 132, 1 winding (PAM), see page A2.28.2. GV: High speed.3. PV: Low speed.
Ratedpower
at 50 Hz
IM 1001 PTO(IM B3)
TypePNkW Code Qty
LS 71 L GV2
PV30.250.09 -
LS 80 L GVPV
0.70.2 MA9 074 B2 2
LS 90 S GVPV
0.850.25 -
LS 90 L GVPV
1.40.5 MA9 144 B2 2
LS 100 L GVPV
2.40.75 MA9 244 B2 2
LS 112 MG GVPV
3.41.1 MA9 344 B2 2
LS 132 SM GVPV
41.2 MA9 404 B2 2
LS 132 M GVPV
6.31.9 MA9 634 B2 2
LS 160 M GVPV
93 MA9 094 C2 2
LS 160 M GVPV
113.7 MA9 114 C2 1
LS 160 L GVPV
134.3 -
LS 160 LU GVPV
155 MA9 154 B2 1
LS 180 L GVPV
18.56.5 -
LS 180 LU GVPV
227.5 MA9 224 B2 1
LS 200 L GVPV
258.5 -
LS 200 LU GVPV
309 -
LS 225 SR GVPV
3411 -
LS 250 ME GVPV
4214 -
LS 250 MF GVPV
5219 -
LS 280 SK GVPV
7528 -
LS 280 MK GVPV
9033 -
LS 315 SP GVPV
11037 -
LS 315 MR GVPV
13244 -
4 - 6 Poles1500-1000 min-1
LS multi-speed closed three-phase asynchronous motors
A2.38
Selection
The motors are for use with quadratic resistive torque machines (centrifugal machines).The high speed power (GV) is that of the standard motor having the same speed in the same frame size (from 80 to 315 included).The motors connection is provided only for one power supply voltage (Dahlander connection) and it does not allow star delta starting.
Use: centrifugal machines
1 winding (Dahlander) - Thermal protections with PTO -n/c or with PTF -n/o IP 55 - 50 Hz - Class F - ΔT 80 K - 400 V - S1
Rated power
at 50 HzRatedspeed
Ratedcurrent
Powerfactor
EfficiencyIEC 60034-2;
1996Starting torque /
Rated torque Weight
TypePNkW
NNmin–1
IN (400 V)A
Cos ϕ100%
η100%
ID / IN IM B3kg
LS 71 M GV1
PV20.250.06
1430640
0.80.4
0.70.6
6598
3.51.5 8.3
LS 71 M GVPV
0.370.07
1430670
1.150.5
0.80.7
6030
42.1 8.3
LS 80 L GVPV
0.550.09
1435715
1.150.6
0.710.48
6946
4.82.3 10.9
LS 80 L GVPV
0.750.12
1425710
2.30.9
0.720.52
6541
4.82.3 10.9
LS 90 S GVPV
1.10.18
1435720
2.81
0.820.47
7152
4.62.9 14
LS 90 L GVPV
1.50.25
1455725
41.5
0.740.56
7451
5.83.4 15.2
LS 100 L GVPV
2.20.37
1435720
5.52.2
0.810.48
7251
5.12.6 24.5
LS 100 L GVPV
30.55
1435715
7.42.6
0.790.52
7558
5.52.7 24.5
LS 112 MU GVPV
40.75
1455730
8.93.2
0.840.51
8266
7.84.3 37
LS 132 SM GVPV
5.51.1
1425715
113.7
0.860.56
8377
5.33.1 55
LS 132 M GVPV
7.51.5
1435720
15.35
0.840.57
8475
5.83.4 60
LS 160 M GVPV
92.2
1465725
18.16.2
0.850.63
84.483.3
7.34.1 85
LS 160 M GVPV
112.8
1465730
21.57.7
0.850.65
87.083.6
7.54.2 85
LS 160 L GVPV
133.3
1465725
25.19.1
0.850.63
87.880.8
7.64.1 100
LS 160 L GVPV
153.8
1460725
28.610.1
0.860.64
88.181.8
7.64.2 100
LS 180 L GVPV
18.54.8
1465730
34.912.1
0.860.67
89.085.2
6.73.7 135
LS 180 LU GVPV
225.3
1460730
40.913.2
0.870.68
89.285.5
6.03.6 165
LS 200 LT GVPV
246
1470730
45.215.4
0.850.63
90.186.0
7.13.7 170
LS 200 L GVPV
307
1475735
55.818.6
0.860.65
90.386.6
6.13.8 205
LS 225 SR GVPV
378.5
1475735
69.221.8
0.850.64
90.889.9
6.84.0 235
LS 225 MG GVPV
4511
1482738
83.126.3
0.850.66
9291.3
74 235
LS 250 ME GVPV
5514
1484738
100.833.1
0.850.66
92.792.4
7.74 320
LS 250 MF GVPV
6516
1484738
118.737.7
0.850.66
9392.8
7.74 320
LS 280 SD GVPV
7519
1484738
136.945.5
0.850.65
9392.8
7.73.9 430
LS 280 MK GVPV
9023
1485740
15954.8
0.870.67
93.890.5
8.74.8 665
LS 315 SP GVPV
11029
1485740
19569.0
0.870.65
93.890.3
8.64.6 825
LS 315 MP GVPV
13235
1485740
23886
0.850.67
94.190.5
8.34.9 790
LS 315 MR GVPV
16042
1485740
288103
0.850.65
94.290.4
8.35.0 825
4 - 8 Poles1500-750 min-1
1. GV: High speed.2. PV: Low speed.
LS multi-speed closed three-phase asynchronous motors
A2.39
Selection example:Speed: 1500-750 min-1-4/8 poles
Power: 15/3.8 kWMounting and position: IM 1001 (IM B3)Mains supply voltage: 400VThermal protection: PTO
Designation:4/8 P LS 160 L 15/3.8 kW IM 1001 (IM B3) - PTO - 400V
Code: MA9 154 M2
Use: centrifugal machines
1 winding (Dahlander) - Thermal protections with PTO -n/c or with PTF -n/o IP 55 - 50 Hz - Class F - ΔT 80 K - 400 V - S1
1. GV: High speed. 2. PV: Low speed.
Selection
Ratedpower
at 50 Hz
IM 1001 PTO(IM B3)
TypePNkW Code Qty
LS 71 M GV1
PV20.250.06 MA9 024 M5 5
LS 71 M GVPV
0.370.07 MA9 034 M4 5
LS 80 L GVPV
0.550.09 MA9 054 M2 2
LS 80 L GVPV
0.750.12 MA9 074 M2 5
LS 90 S GVPV
1.10.18 MA9 014 M2 5
LS 90 L GVPV
1.50.25 MA9 024 M2 5
LS 100 L GVPV
2.20.37 MA9 024 M4 5
LS 100 L GVPV
30.55 MA9 034 M2 5
LS 112 MU GVPV
40.75 MA9 044 M2 5
LS 132 SM GVPV
5.51.1 MA9 554 M2 3
LS 132 M GVPV
7.51.5 MA9 754 M2 3
LS 160 M GVPV
92.2 MA9 094 M2 2
LS 160 M GVPV
112.8 MA9 114 M2 2
LS 160 L GVPV
133.3 MA0 004 00 2
LS 160 L GVPV
153.8 MA9 154 M2 2
LS 180 L GVPV
18.54.8 MA0 004 02 2
LS 180 LU GVPV
225.3 MA0 004 04 1
LS 200 LT GVPV
246 -
LS 200 L GVPV
307 MA0 004 08 1
LS 225 SR GVPV
378.5 -
LS 225 MG GVPV
4511 -
LS 250 ME GVPV
5514 -
LS 250 MF GVPV
6516 -
LS 280 SD GVPV
7519 -
LS 280 MK GVPV
9023 -
LS 315 SP GVPV
11029 -
LS 315 MP GVPV
13235 -
LS 315 MR GVPV
16042 -
4 - 8 Poles1500-750 min-1
LS multi-speed closed three-phase asynchronous motors
The motors are for use with quadratic resistive torque machines (centrifugal machines).The high speed power (GV) is that of the standard motor having the same speed in the same frame size (from 80 to 315 included).The motors connection is provided only for one power supply voltage (Dahlander connection) and it does not allow star delta starting.
6 - 12 poles1000-500 min-1
1. GV: High speed.2. PV: Low speed.
LS multi-speed closed three-phase asynchronous motors
A2.41
Selection example:Speed: 1000-500 min-1-6/12 poles
Power: 1.5/0.25 kWMounting and position: IM 1001 (IM B3)Mains supply voltage: 400V
Designation:6/12 P LS 100 L 1.5/0.25 kW IM 1001 (IM B3) - PTO - 400V
LS 132 S MAPE 1018 MAPE 1031 13 MASPC 108 MVA00002
LS 132 M MAPE 1036 MAPE 1038 16 MASPC 114 MVA00064
LS 160 L MAPE 1019 MAPE 1032 16 MASPC 109
LS 160 M MAPE 1019 MAPE 1032 16 MASPC 109
LS 160 LR MAPE 1019 MAPE 1032 16 MASPC 109
LS 160 MP MAPE 1019 MAPE 1032 16 MASPC 109
LS 180 MAPE 1037 MAPE 1039 16 MASPC 115
LS 200 MAPE 1020 MAPE 1033 21 MASPC 110
LS 225 MAPE 1021 MAPE 1034 29 MASPC 111
LS 250 MAPE 1022 MAPE 1035 36 MASPC 112
LS 280 MAPE 1023 MAPE 1036 36 MASPC 113
LS 315 MA00 0241 MA00 0242 36 MASPC 116
1. Aluminium terminal box p. A2.192. Cable lenght: 1 metre. Conductor number: 6 + 1 (section according to the power and to the mains supply voltage). Cable connected to the board. Standard terminal box.
2poles3000 min-1
4poles1500 min-1
6poles1000 min-1
8poles750 min-1
LS totally enclosed three-phase asynchronous motors