Top Banner
LOGO Orthodontic Bone Anchors Parameters for Success
24

LOGO Orthodontic Bone Anchors Parameters for Success.

Dec 15, 2015

Download

Documents

Jaeden Eversley
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: LOGO Orthodontic Bone Anchors Parameters for Success.

LOGO

Orthodontic Bone Anchors

Parameters for Success

Page 2: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO

1. OBA history – MK I MK II 1. OBA history – MK I MK II

2. Delayed versus immediate loading 2. Delayed versus immediate loading

3. Common indications 3. Common indications

4. Conclusion 4. Conclusion

Page 3: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO

2000 2001

+ tube + tube

1999 2002

Page 4: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO

2000 20022001

+ bracket + bracket

Page 5: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO

- slot - slot

Page 6: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO

Mommaerts M, Correia P, Nuttens S. Experiencia clinica com o “Ortho Bone Anchor – OBA” – Relatorio Preliminar Rev Port Estomat Med Dent Cir Maxilofac 42: 131-135, 2001

Publications on MK I Publications on MK I

Mommaerts MY, Michiels ML, De Pauw GA. A 2-year outcome audit of a versatile orthodontic bone anchor. J Orthod. 32: 175-81, 2005

Page 7: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO

Placement between 2000 & 2002 Follow-up till 2004 18 patients 35 OBA’s

Results of MK I study

8,6% premature loss 8,6% premature loss

Page 8: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO

SubtitleSubtitle

Conclusions of MK I study

Bayonet shaping of neck

Diminishing height of coronal screw head

Protection by fixed appliances

Texturising of fixation part

Page 9: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO

1. OBA history 1. OBA history

2. Delayed versus immediate loading with MK II 2. Delayed versus immediate loading with MK II

3. Parameters for success 3. Parameters for success

4. Conclusion 4. Conclusion

Page 10: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO Location

Mandible: 31 4

Maxilla: 13 11

Removed OBAs 2002-2005 Removed OBAs 2002-2005

Distal to 2,3,4 Distal to 5,6,7

Piriform aperture Zygomatic crest

Page 11: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO Delayed versus immediate loading

Delayed maxilla

Immediate maxilla

Delayed mandible

5mm (11): 17mm (4): 0

03 mob+infl

1935

0057

5mm (46): 77mm (8): 0

0 2030

5mm (30): 57mm (13): 4

12 mob+infl1 lost mob

1523Immediate mandible

Mobile screws upon removalPremature loss

#Years in

situ

Removed OBAs Removed OBAs Always 5mm coronally

Always coronal

No inflam response

Page 12: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO

1. OBA history 1. OBA history

2. Delayed versus immediate loading 2. Delayed versus immediate loading

3. Common indications 3. Common indications

4. Conclusion 4. Conclusion

Page 13: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO Indications (all OBAs in situ > 3 m)

35

3

4

1

11

8

4

5

3

0 10 20 30 40 50

mandible

maxilla

Page 14: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO

most common indication most common indication

Page 15: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO 2 anchors for closing diastemas in 4 q!

Page 16: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO

Page 17: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO

1. OBA history 1. OBA history

2. Delayed versus immediate loading 2. Delayed versus immediate loading

3. Indications 3. Indications

4. Conclusion MK II study 4. Conclusion MK II study

Page 18: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO

Coronal 5mm screws are vulnerable

No big difference between immediate & delayed loading in mandible

2 important

Page 19: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO Simple hook = workhorse

March 2003 March 2003

October 2005 October 2005

Page 20: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO Brackets in special cases

Page 21: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO

Better pull than push!

Page 22: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO Do not remove a mobile OBA too quickly!

April 2002 April 2002

October 2003 October 2003

Page 23: LOGO Orthodontic Bone Anchors Parameters for Success.

Your site here

LOGO Incision not necessarily in fixed gums!

Page 24: LOGO Orthodontic Bone Anchors Parameters for Success.

LOGO

Thank you!