Top Banner
Instructions-Parts Light Tower Kit Diagnostic indicator for use with single supply, tandem supply, and other GCA equipped systems. Important Safety Instructions Read all warnings and instructions in your supply system operation and repair manuals. Save all instructions. 1 2 3 1 2 (CMXXXX, GDXXXX) ti10920a ti10921b 3 D200s, D200, S20 2 3 r_255467_312493c Model 255467 For Single Supply Systems with DataTrak and D60 1 Model 255468 For Electric Crossover Tandem Supply Systems and Warm Melt Systems (TCXXXX, TDXXXX, TWXXX Ref. Description Qty . 1 LIGHT TOWER, Model 255467 1 2 SCREW, machine 3 NUT, hex Ref. Description Qty . 1 LIGHT TOWER, Model 255468 1 2 SCREW, machine 3 NUT, hex 312493G EN
4

Light Tower Kit · Feed the light tower cable through the hole in the light tower mounting bracket. 3. Attach light tower to bracket with screws (2) and hex nuts (3). 4. Plug connector

Aug 15, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Light Tower Kit · Feed the light tower cable through the hole in the light tower mounting bracket. 3. Attach light tower to bracket with screws (2) and hex nuts (3). 4. Plug connector

Instructions-Parts

Light Tower KitDiagnostic indicator for use with single supply, tandem supply, and other GCA equipped systems.

Important Safety InstructionsRead all warnings and instructions in your supply system operation and repair manuals. Save all instructions.

1

2

3

1

2

(CMXXXX, GDXXXX)

ti10920a ti10921b

3

D200s, D200, S20

2

3r_255467_312493c

Model 255467 For Single Supply Systems with DataTrak

and D60

1

Model 255468 For Electric Crossover Tandem Supply Systems and Warm Melt Systems (TCXXXX, TDXXXX,

TWXXX

Ref. DescriptionQty

.1 LIGHT TOWER, Model 255467 12 SCREW, machine3 NUT, hex

Ref. DescriptionQty

.1 LIGHT TOWER, Model 255468 12 SCREW, machine3 NUT, hex

312493G EN

Page 2: Light Tower Kit · Feed the light tower cable through the hole in the light tower mounting bracket. 3. Attach light tower to bracket with screws (2) and hex nuts (3). 4. Plug connector

Installation

2 312493G

Installation

Mounting Provided (Rams)1. Loosen six captive screws (A) and disassemble

shrouds (B) from supply system.

2. Feed the light tower cable through the hole in the light tower mounting bracket.

3. Attach light tower to bracket with screws (2) and hex nuts (3).

4. Plug connector at end of light tower cable into corre-sponding green connector on the DataTrak or dis-play module harness.

For tandem systems, plug light tower connector into fluid control module connector number 2. See your supply system manual for electrical connection schematic.

5. Reattach the shrouds (B).

Mounting Not Provided1. Locate the light tower so it is visually unobscured.

2. Drill the hole pattern for the light tower.

NOTE: A 1:1 drill template has been provided on this page.

FIG. 1: Shroud Removal

FIG. 2: Hole Pattern

A

B

B

r_289105_312375a

Feed cablethrough

MountingHoles

ti10922a

FIG. 3: Electrical Connection

FIG. 4: Hole Pattern

From DataTrak/Display

2

3

ti10920a

0.85 in.0.70 in.

0.80 in. (20 mm)Diameter

(22 mm)

(18 mm)

0.26 in. (7 mm)

4x 10-32 UNCEqually Spaced2.10 in. (53 mm)Bolt Circle

3x 0.20 in. (5 mm)Equally Spaced1.57 in. (40 mm)Bolt Circle

Diameter

Page 3: Light Tower Kit · Feed the light tower cable through the hole in the light tower mounting bracket. 3. Attach light tower to bracket with screws (2) and hex nuts (3). 4. Plug connector

Accessories

312493G 3

3. Feed the light tower cable through the hole of the light tower mounting pattern. See FIG. 2.

4. Attach the light tower to the hole pattern with the screws and hex nuts provided.

5. Plug the connector at the end of the light tower cable into port 1 found on the Advanced Display Module (ADM).

Accessories

Light Tower Extension Cables

TroubleshootingLight Tower Signals

NOTE: See supply systems manual for details of the specific errors associated with the light tower sig-nals.

E-Flo iQ Dispense System Troubleshooting

See the E-Flo iQ Dispense System Operation manual no. 333587 for more information.

E-Flo iQ Light Tower Signals

Drill TemplateNOTE: Drill Template is 1:1 Scale.

FIG. 5: Advanced Display Module

Part No. Length (meter)

122487 1.5

121728 4.0

124003 5.0

121005 15

121006 50

Signal Description

Green on only(Only model 255468)

System is powered up and there are no error conditions present.

Yellow flashing A low priority error exists.

Yellow on A medium priority error exists.

Red flashing A high priority error exists.

Red on The system is shut down due to error conditions.

Signal Description

Off System is not active.

Green on onlySystem is active and there are no error conditions present.

Green blinking Heat is warming up.

Yellow on An advisory exists.

Yellow blinking A deviation exists.

Red solidThe system is shut down due to an alarm occurring.

Page 4: Light Tower Kit · Feed the light tower cable through the hole in the light tower mounting bracket. 3. Attach light tower to bracket with screws (2) and hex nuts (3). 4. Plug connector

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice.

For patent information, see www.graco.com/patents.

Original instructions. This manual contains English. MM 312493

Graco Headquarters: MinneapolisInternational Offices: Belgium, China, Japan, Korea

GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA

Copyright 2007, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.www.graco.com

Revision G, May 2020