Top Banner
44

lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

Aug 19, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:25 Pagina 1

Page 2: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

2

Dear customer,

SD3 is very proud to introduce our new catalogue to you.New products, new design, fluent explanations and system views have been our leitmotiv for this latest realisation.

You will find inside a synthetic view of how SD3 works and how it has progressed.

This edition has been enriched with an enlarged range of products in order toalways supply the most complete offer in fire alarm systems.

The European standard and CE CPD certifications become more and more essentialto be recognised as a trustful manufacturer. SD3 constantly aims to meet the latestrules and standards to deliver an updated passport certification.

Our factories SEFI and FARE, pillars of SD3, are now in a new modernisedbuilding including cutting-edge manufacturing and logistic processes.

All this organisation enables us to expand our presence on the market and to getyour confidence to build an excellent partnership.

We wish you the best future with SD3.

Bernard MongelliManaging Director

B-03 2011

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:25 Pagina 2

Page 3: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

3

1/ CONVENTIONAL SYSTEMS.......................................................................................................................CONVENTIONAL GENERAL VIEW...................................................................................................

A/ PANELS……………...............…………….....................……………………………………..............B/ FIRE DETECTORS………….………………………..........................….....………..…………………..C/ MANUAL CALL POINTS……………………….....................................................................................D/ AIR DUCT DETECTION...............................................................................................................E/ STAND ALONE SMOKE ALARM DETECTOR.....................................................................................F/ LINEAR HEAT DETECTION..........................................................................................................

2/ INTELLIGENT / INTERACTIVE PANELS AND DETECTORS.......................................................................ADDRESSABLE GENERAL VIEW.........................................................................................................

A/ PANELS………………………………………….........................…………………………………………....B/ INTELLIGENT FIRE DETECTORS………………………………..........................………………................C/ ADDRESSABLE MANUAL CALL POINTS……………………….............................................................D/ LOOP SOUNDERS ……………………………………………................................................................E/ INTERFACE LOOP UNITS………………….......................................................................................F/ PROGRAMMING AND MAINTENANCE TOOL……………………........................................................

SPECIFIC PRODUCTS GENERAL VIEW..............................................................................................

3/ LINEAR SMOKE DETECTORS.................................................................................................................

4/ AIR SAMPLING DETECTION...................................................................................................................

5/ EXPLOSION HAZARD AREA PRODUCTS………………………………………...............................................

6/ WIRELESS SOLUTIONS...........................................................................................................................

7/ ACCESSORIES FOR FIRE SYSTEMS…………………………………………….................................................

8/ MONITORING SOFTWARE…………………………………………………….....................................................

9/ HEPHEA POWER SUPPLY RANGE..........................................................................................................

10/ GAS DETECTION…………………………………………………………………..........................................A/ CONVENTIONAL GAS DETECTORS………………….........................................................................5.B/ ADDRESSABLE PANELS……………………………………….........................……................................C/ ADDRESSABLE GAS DETECTORS................................................................................................D/ EXPLOSION PROOF GAS DETECTION.......................................................................................

11/ MARINE...............................................................................................................................................A/ ADDRESSABLE PANELS..................................................................................................................B/ ADDRESSABLE DETECTORS..........................................................................................................

12/ VOICE EVACUATION SYSTEMS………………………………………………...............................................

13/ ELECTRIC LOCK FOR EMERGENCY EXIT DOORS……………………….....................................................14/ FIRE ALARM CABLE................................................................................................................................

15/ MAINTENANCE EQUIPMENT.................................................................................................................A/ TEST AND MOUNTING TOOLS.......................................................................................................B/ SPARE PARTS............................................................................................................................

8-98-9

101214151515

16-1716-17

182122222323

24-25

26

28

29

30

31

33

34

3535363637

383838

39

4040

414142-43

TABLE OF CONTENTS

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:25 Pagina 3

Page 4: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

4

SD3 Presentation

THE COMPANY

Founded in 2002, SD3 Security Detection Direct Distribution belongs to the 1st Frenchfire detection systems factories :

- FARE that designs and manufactures the whole range of detectors.

- SEFI that designs and manufactures the whole range of fire alarm panels.

SD3 represents their export department all over the world.

We use the concept of direct delivery from factories, providing flexibility andcompetitivity.

CERTIFICATIONSOur EN54 and CE certification according

to CPD by a notified body is an export passport to build partnerships.

MADE IN FRANCE

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:26 Pagina 4

Page 5: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

5

PRODUCTS A complete range for many applications.

SD3 offers a complete range of fire detection products dedicated to:

- Installers specialized in security systems- Distributors with technical assistance- Security systems manufacturers.

As we are a flexible structure directly in contact with factoriesand R&D departments, we are able to meet all your requirements tomatch your market.

Moreover, we are able to customize your products with yourown brand, logo, and language.

SERVICES Reactive and quality services.

Commercial department : our reliable sales team is able toinform and advise you, adapting our offers to each application.

Technical support : our technical support team is able toanswer all your questions and organize trainings all over theworld in order to help you get the right knowledge on the wholeSD3 products range.

Marketing department : our marketing team is ready toprovide you all necessary tools and useful information tointroduce our range in your country.

Logistic support : our professional experts are able to informyou step by step about the logistical process, from your order tothe delivery.

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:26 Pagina 5

Page 6: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

6

SD3 ORGANISATION

Created in 1989, FARE is specialised in developing and

manufacturing conventional and addressable detectors.

FARE aims to develop its business through the quality

design and process of its detectors.

FARE owns a tool of modern production, making high

investment in order to ensure a large production

capacity in SMD cabling.

FARE has also its own R&D department able to design

new detectors or customise them for SD3 partners

thanks to a professional and dynamic staff.

FARE CERTIFICATIONS :

ISO / AFNOR / BOSEC / CPD by notified body

SEFI was founded in 1970. The company

manufactures conventional and addressable fire

alarm panels and auxiliaries.

SEFI owns last generation production tool SMD

machines and sophisticated monitoring tests.

SEFI has also its own R&D department.

SEFI CERTIFICATIONS :

ISO / AFNOR / BOSEC / VDS / CPD by notified body

Gas detectors and panels,Power supply Location: Verona ITALY

First French group manufacturer

FIRE ALARM SYSTEMDetectors, Call points, ModulesLocation: FRANCE

Conventional and Intelligent/Addressable panelsLocation: FRANCE

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:26 Pagina 6

Page 7: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

7

AccessoriesLocation: Massy (Paris)FRANCE

EXPORT DEPARTMENT Commercial relationshipsTechnical trainingsAssistanceDistribution under the factoriesbrand all over the worldLocation : Massy (Paris) FRANCE

CUSTOMERS

STEM FACTORIES SD3 view of factories and logistic

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:26 Pagina 7

Page 8: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

CONVENTIONAL GENERAL VIEW

8

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:26 Pagina 8

Page 9: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

9

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:26 Pagina 9

Page 10: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

CONVENTIONAL SYSTEMS

2 zones ALPHA 2 Options

PANELS

10

ALPHA 22 ZONES FIRE DETECTION CONVENTIONALPANEL, max 32 detectors and/or MCP perline. Alarm/fault output relays , 1 monitored sounders line + 3 output relays and 1 programmable open collector. Alarm prealarm management. Compact panel not expandable.Needs 2 internal batteries 12V/4Ah

2 WAYS RELAY output module, NO-NC 30V/1A tobe plugged inside ALPHA2 panel

SR2/24

EX4A4

EX4A4ex

DEAG

REP4R

R4P2

From 4 up to 12 zones ALPHA 4/8/12 Options

ALPHA 4/8/12

12 ZONES FIRE DETECTION CONVENTIONALPANEL equipped with 4 zones(max 12 zones) - max 32 detectors and/orMCP per line. Alarm/fault relays,1 monitored sounders line,4 programmable open collectors,1 programmable input.Alarm prealarm/management + Day nightmode. Expandable panel with availibilityof 2 rooms for one or two 4 zones expansion (EX4A4) or one or two Extinguishing boards (DEAG). EN54-2,EN54-4 AFNOR, BOSEC, CE CPD,EN12094-1 with extinguishing board(DEAG). Needs 2 batteries 12V/7Ah

4 ZONES EXPANSION BOARD, max 32 detectorsand/or MCP per line, 1 or 2 EX4A4 boards canbe plugged in ALPHA 4/8/12 and permitsto expand the panel to 8 (with 1xEX4A4) or to12 zones(with 2xEX4A4)

4 ZONES EXPANSION BOARD Ex VERSION to be used with explosion hasard area detectors, max 10 detectors per line, 1 or2xEX4A4ex can be plugged in ALPHA4/8/12 andpermits to include max 8 intrisically detectorzones

1 ZONE EXTINGUISHING EXPANSION BOARD, to be used for management of 1 extinguishingchannel. All monitored lines : Extinguishing actuators, Evacuation panels, Release button,Abort button, Low presssure contact. Thisboard permits to convert ALPHA 4/8/12 panel ina detection-extinguishing panel

4 WAYS RELAY CARD, NO-NC 30V/1A , to beplugged inside the panel, connection by wireswith programmable open collectors of ALPHA 4/8/12

4 WAYS RELAY CARD, NO-NC 30V/1A, to beplugged inside the panel, serial communication,permits to repeat states of the panel on4 relays

R12P2 12 WAYS RELAY CARD, NO-NC 30V/1A, to beplugged inside ALPHA 4/8/12 panel, serial communication, permits to repeat states of thepanel on 12 relays

R7P2 7 WAYS RELAY CARD, NO-NC 30V/1A, to beplugged inside the panel, serial communication, permits to repeat states of thepanel on 7 relays

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:27 Pagina 10

Page 11: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

11

CONVENTIONAL SYSTEMS

ALPHA 16/248248 ZONES FIRE DETECTIONCONVENTIONAL PANEL equipped with1 6 z o n e s e x p a n d a b l e t o 2 4 8 -Alphanumeric display 2x16 - Mimicpanel integrated for 32 zones (alarm,fault, disable, test). Max 32 detectorsand/or MCP per line. Alarm/fault relays, 1 monitored sounders line + 3 output relays and 1 programmable opencollector. Alarm prealarm management.Needs 2xbatteries 12V/12Ah

8 ZONES EXPANSION BOARDmax 32 detectors and/or MCP per line, to be plugged inside ALPHA16/248 panel

EX8Z

From 16 up to 248 zones ALPHA 16/248 Options

PANELS

8 WAYS RELAY CARD, NO-NC 30V/1A, to be plugged inside ALPHA16/248 panel,programmable relays, permits to repeat statesof the panel on 8 relays

EX8R

Accessories for panels

TR-SDIREMOTE INDICATOR PANEL with leds and function keys, to repeat general alarm and fault, local test ledsand silence buzzer

TRI 1010 ZONES REMOTE INDICATOR PANEL with leds and function keys, permits to repeat fire alarm zones, local test ledsand silence buzzer

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:27 Pagina 11

Page 12: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

CONVENTIONAL SYSTEMS

12

OC05CONVENTIONAL OPTICAL SMOKED E T E C TOR, 1 remote led output,EN54-7, CE according to CPD.

UNIVERSAL BASE WITH STICK ADDRESS SOCKETfor 05-range conventional and addressabledetectors.

S05SE

FIRE DETECTORS

05 range Bases and accessories

TRC05CONVENTIONAL RATE OF RISE + FIXEDHEAT DETECTOR, T° = 62°C, + 9°C/min, 1 remote led output, EN54-5, CE according to CPD.

TSC05-A1SCONVENTIONAL FIXED HEAT DETECTOR, T°= 62°C, 1 remote led output, EN54-5,CE according to CPD.

OC05.12 or OC05.12-ARCONVENTIONAL OPTICAL SMOKEDETECTOR, for 12V security type systems, to be used with R05 relayboard, alarm latched or autoresettable(AR version)

12Vdc application with 05 range

TRC05.12 or TRC05.12-ARCONVENTIONAL RATE OF RISE + FIXEDHEAT DETECTOR, T° = 62°C, + 9°C/min,for 12V security type systems, to beused with R05 relay board, alarm latched or autoresettable (AR version)

TSC05-A1S.12 or TSC05-A1S.12-ARCONVENTIONAL FIXED HEAT DETECTOR, T° = 62°C, for 12V security type systems, to be used with R05 relay board, alarm latched or autoresettable(AR version)

TSC05-BSCONVENTIONAL FIXED HEAT DETECTOR, T°= 75°C, 1 remote led output, EN54-5,CE according to CPD.

TSC05-BS.12 or TSC05-BS.12-ARCONVENTIONAL FIXED HEAT DETECTOR,T° = 75°C, for 12V security type systems,to be used with R05 relay board, alarm latched or autoresettable (AR version)

FLUSHMOUNTING PIECE FOR BASE (Base not included), permits to flushmount a 05range detector.

PES05

BASE WITH INTERNAL SOUNDER 95db @ 1m,Possibility to select 6 tones and 3 intensitivitylevels, EN54-3, CE according to CPD.

SOUND05+S05

RELAY BOARD (12V or 24V) for 05 detectors (to be plugged in S05), NO-NC 30V/1A

R05

PROTECTION PLATE for S05 base, permits tocover a base without detector.

Universal base with GLANDS HOLE for 05range,base for tubes connections.

WATERPROOF universal base with glands for 05range (IP65), base for tubes connectionssupplied with glands

ANTIVANDALISM protection grid

BRI/EM+ S05

BRI + S05

CS05

GAV

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:28 Pagina 12

Page 13: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

13

CONVENTIONAL SYSTEMS

MCY2+S95CONVENTIONAL MULTISENSOR (OPTICAL - HEAT) DETECTOR, 1 remote led output, EN54-7 , base included.

IRY2+S95CONVENTIONAL INFRARED FLAME DETECTOR, 1 remote led output, vision cone ± 45°, Distance max 25m, EN54-10,CE according to CPD , base included.

IRY2-IP65CONVENTIONAL INFRARED FLAME DETECTOR, 1 remote led output, vision cone ± 45°, Distance max 25m, EN54-10, CE according to CPD , IP65 box, dim 225x175x80.

SUV+ESCONVENTIONAL ULTRA VIOLET FLAME DETECTOR, 1 remote led output, vision cone ± 60° , radiation analysis rangefrom 80nm to 270nm, base included.

FIRE DETECTORS

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:28 Pagina 13

Page 14: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

CONVENTIONAL SYSTEMS

14

DMCL05CONVENTIONAL MANUAL CALL POINTresettable with key without breakingglass, led and alarm resistor integrated,RED colour, EN54-11, CE according toCPD

TRANSPARENT LIFT-UP protective cover for MCP,permits a double action (supplied with protectionlabel)

VPDM

MANUAL CALL POINTS

DMCL05-JCONVENTIONAL MANUAL CALL POINTresettable with key without breakingglass, led and alarm resistor integrated,YELLOW colour

KIT OF 10 RESET KEYS for MCP KCTDM

PLASTIC FRAME for flush mounting MCPPEDM

WATERPROOF IP65 HOUSING BOX for conventionaland addressable manual call point with reset(call point not included)

STS6535

05 range 05 MCP Accessories

DMCL05-BCONVENTIONAL MANUAL CALL POINTresettable with key without breakingglass, led and alarm resistor integrated,BLUE colour

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:28 Pagina 14

Page 15: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

15

CONVENTIONAL SYSTEMS

AIR DUCT DETECTION

LINEAR HEAT DETECTION

HC68LINEAR HEAT DETECTION cable 68° (price per meter) connectable directly to conventional panels or addressable modules

HC105LINEAR HEAT DETECTION cable 105° (price per meter) connectable directly to conventional panels or addressable modules

BTG05-P5901AIR DUCT DETECTOR HOUSING for 05 range (detector not included), dimensions 220x186x105mm, IP55

STAND ALONE SMOKE ALARM

VESTADOMESTIC PHOTOELECTRIC SMOKEALARM DETECTOR with 9V battery, CE EN14604 according to CPD

VESTA VESTA Accessories

PLUG IN CARD with NO contact, permits to repeat the state of alarm (for intrusion panels)

DAAF-REL

PLUG IN CARD for 2 wires interconnection, permits to connect one or more VESTA in 2 wires network

DAAF-INTER

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:29 Pagina 15

Page 16: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

16

ADDRESSABLE GENERAL VIEW

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:29 Pagina 16

Page 17: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

17

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:29 Pagina 17

Page 18: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

INTELLIGENT/INTERACTIVE PANELS ANDDETECTORS

From 1 to 128 addresses HEPHAIS 128 Options

PANELS

18

HEPHAIS 128INTELLIGENT/INTERACTIVE COMPACTCONTROL PANEL, 128 ADDRESSES, 2 master loops or 4 spur circuits (opencircuit with max 32 addresses), 99 ZONES, 1000 memory events,1 monitored sounders line+ 5 programmable output relays,1xRS232 serial output for printer orremote control panel, 2 programmableinputs. The panel can be set by keyboardor software. Needs 2 internal batteries12V/7Ah. EN54-2, EN54-4, CE accordingto CPD

7 RELAY CARD, NO-NC 30V/1A, to be plugged inside the panel, serial communication, permitsto repeat states of the panel on 7 relays

R7P2

ALPHA RE

R12P2

C20R

From 1 to 400 addresses HEPHAIS 1600 NE Options

HEPHAIS 1600 NEINTELLIGENT/INTERACTIVE COMPACTCONTROL PANEL, NOT EXPANDABLE,400 ADDRESSES, 2 master loops or 4 spur circuits (open circuit with max 32addresses), 1000 ZONES, 2700 memoryevents, 2 monitored sounders lines +3 programmable output relays, 1xRS232serial output for printer and 1xRS485serial output for remote control panel,4 programmable inputs, RS422 JBUS monitoring output , needs 2 internalbatteries 12V/12Ah. EN54-2, EN54-4,CE according to CPD

REMOTE USER INTERFACE PANEL with serial 485connection, alphanumeric display LCD 160 characters and keyboard

12 RELAY CARD, NO-NC 30V/1A, to be pluggedinside the panel, serial communication, permitsto repeat states of the panel on 12 relays

20 RELAY CARD, NO-NC 30V/1A, to be pluggedinside the panel, serial communication, permitsto repeat states of the panel on 20 relays

R7P2 7 RELAY CARD, NO-NC 30V/1A, to be pluggedinside the panel, serial communication, permitsto repeat states of the panel on 7 relays

SPLITTING MASTER LOOP CARD, permit to splitone loop up to 4 isolated loops to be plugged inside the panel and completed with ICC05 (onefor each split)

TELEHEPHAIS 128 SOFTWARE PROGRAMMING TOOL forHEPHAIS 128, uploading/downloading

12 RELAY CARD, NO-NC 30V/1A, to be pluggedinside the panel, serial communication, permitsto repeat states of the panel on 12 relays

R12P2

REMOTE USER INTERFACE PANEL with serial 485connection, alphanumeric display LCD 160 characters and keyboard

ALPHA RE

TELEHEPHAIS 1600

SOFTWARE PROGRAMMING TOOL forHEPHAIS 1600

X4EVAC 4 MONITORED WAYS SOUNDER CIRCUIT extension board, permits to multiply 1 soundercircuit in 4 activated simultaneously, to beplugged inside the panel

4ISOL

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:30 Pagina 18

Page 19: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

19

7 RELAY CARD, NO-NC 30V/1A, to be pluggedinside the panel, ser ial communication,permits to repeat states of the panel on 7relays

R7P2

12 RELAY CARD, NO-NC 30V/1A, to be pluggedinside the panel, serial communication,permits to repeat states of the panel on 12relays

R12P2

INTELLIGENT/INTERACTIVE PANELS ANDDETECTORS

ALPHA RE

MGNET

RF H 1600

From 1 to 1600 addresses HEPHAIS 1600 Options

HEPHAIS 1600-400/L MODULAR INTELLIGENT/INTERACTIVEFIRE CONTROL PANEL MAX 1600POINTS, 16 LOOPS - supplied asstandard for 400 points on 2 masterloops (max 200 addresses / loop) or4 spur circuits, expandable up to7 x MG2B (loop boards), EN54-2,EN 54-4, in large box with integratedfront panel, 1000 zones,2700 memory events, 2 monitoredsounders lines + 3 programmableoutput relays, 1xRS232 serial outputfor printer and 1xRS485 serial outputfor remote control panel,4 programmable inputs, RS422 JBUSmonitoring output,networkable with MGNET board. Needs 2 internal batteries 12V/17Ah. EN54-2, EN54-4,CE according to CPD

REMOTE USER INTERFACE PANEL with serialconnection, alphanumeric display LCD 160characters and keyboard

NETWORK CARD, must be plugged in eachpanel for network application, network donewith RS485 redundant connection

USER INTERFACE FRONT PANEL ( c o m m a n da n d c o n t r o l ) w i t h alphanumeric display160 characters and keyboard, 19 inches, 3U,can be integrated in cabinet or in CO3U console

MG2B EXTENSION MODULE 2 LOOPS (max 200 pointsper loop) or 4 spur circuits (max 32 points percircuit) to be plugged inside the panel

CO3U PLASTIC BOX CONSOLE for RFH 1600 frontpanel

HEPHAIS 1600-400/SMODULAR INTELLIGENT/INTERACTIVEFIRE CONTROL PANEL MAX 1600POINTS, 16 LOOPS - supplied as standard for 400 points on 2 masterloops (max 200 addresses/loop)or 4 spur circuits, expandable up to7 x MG2B (loop boards), EN54-2, EN 54-4, in small box with integratedfront panel, 1000 Zones,2700 memory events, 2 monitored

sounders lines + 3 programmableoutput relays, 1xRS232 serial outputfor printer and 1xRS485 serial outputfor remote control panel,4 programmable inputs, RS422 JBUSmonitoring output , networkable with MGNET board.Needs 2 internal batteries 12V/12Ah.EN54-2, EN54-4,CE according to CPD

PANELS

IE2M IE2M is an extension board with connectors allowing to connect from 2 to 4 MG2B. Thisboard permits to expand the panel from 10 to16 loops. Necessary if more than 10 loops needed.

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:30 Pagina 19

Page 20: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

HEPHAIS 1600-400/L BBMODULAR INTELLIGENT/INTERACTIVEFIRE CONTROL PANEL MAX 1600POINTS, 16 LOOPS - supplied as standardfor 400 points on 2 master loops (max200 addresses/loop) or 4 spur circuits, expandable up to 7 x MG2B (loop boards),EN54-2, EN 54-4, in large boxwithout front panel, 1000 Zones, 2700memory events, 2 monitoredsounders lines + 3 programmable outputrelays, 1xRS232 serial output for printer

and 1xRS485 serial output for remotecontrol panel, 4 programmable inputs,RS422 JBUS monitoring output,networkable with MGNET board. Needs2 internal batteries 12V/17Ah. EN54-2,EN54-4, CE according to CPD

From 1 to 1600 addresses

INTELLIGENT/INTERACTIVE PANELS ANDDETECTORS

PANELS

20

HEPHAIS 1600-400/S BBMODULAR INTELLIGENT/INTERACTIVEFIRE CONTROL PANEL MAX 1600 POINTS,16 LOOPS - supplied as standard for 400points on 2 master loops (max 200 addresses/loop) or 4 spur circuits,expandable up to 7 x MG2B (loop boards),EN54-2, EN 54-4, in small box withoutfront panel, 1000 Zones, 2700 memoryevents, 2 monitored sounders lines +3 programmable output relays, 1xRS232serial output for printer and 1xRS485 serial output for remote control panel,4 programmable inputs, RS422 JBUSmonitoring output, networkable withMGNET board. Needs 2 internalbatteries 12V/12Ah. EN54-2, EN54-4, CE according to CPD

HEPHAIS 1600-400 LPMMODULAR INTELLIGENT/INTERACTIVEFIRE CONTROL PANEL MAX 1600 POINTS,16 LOOPS - supplied as standard for 400points on 2 master loops (max 200adresses/loop) or 4 spur circuits, expandable up to 7 x MG2B (loop boards),EN54-2, EN 54-4, in large metall icwith integrated front panel, 1000Zones, 2700 memory events, 2 monitoredsounders lines + 3 programmableoutput relays, 1xRS232 serial output forprinter and 1xRS485 serial output forremote control panel, 4 programmableinputs, RS422 JBUS monitoring output,networkable with MGNET board. Needs 2internal batteries 12V/17Ah. EN54-2,EN54-4, CE according to CPD

TELEHEPHAIS 1600SOFTWARE PROGRAMMING TOOL forHEPHAIS 1600

20 RELAY CARD, NO-NC 30V/1A, to be pluggedinside the panel, serial communication, permits torepeat states of the panel on 20 relays

C20R

4 MONITORED WAYS SOUNDER CIRCUITextension board, permits to multiply 1sounder circuit in 4 activated simultaneously,to be plugged inside the panel

X4EVAC

INTERNAL SERIAL FLUSH MOUNTED PRINTERcan be directly mounted in metallic box ofHEPHAIS 1600 or through SUPIMP piece forplastic box

IMP

MOUNTING KIT to flushmount IMP printer inLARGE PLASTIC box of HEPHAIS 1600

SUPIMP

EXTERNAL SERIAL PRINTER, dimensions165x135x50mm

IMP/E

PACK OF 10 THERMIC PAPER ROLLSKCT10

SPLITTING MASTER LOOP CARD, permits tosplit one loop up to 4 isolated loops to be plugged inside the panel and completed withICC05 (one for each split)

4ISOL

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:31 Pagina 20

Page 21: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

21

INTELLIGENT/INTERACTIVE PANELS ANDDETECTORS

OA05INTELLIGENT/INTERACTIVE OPTICALSMOKE DETECTOR, microprocessorbased, 1 programmable remote alarmindicator output, 8 levels sensitivity setting, EN54-7 CE according to CPD

INTELLIGENT FIRE DETECTORS

05 range Bases

TA05INTELLIGENT/INTERACTIVE HEATDETECTOR, static or/and rate of rise,microprocessor based ,1 programmable remote alarmindicator output, 6 levels sensitivity setting, EN54-5, CE according to CPD

MA05INTELLIGENT/INTERACTIVEOPTICAL-HEAT DETECTOR, multicriteriaor combined, microprocessor based,1 programmable remote alarm indicator output, 8 levels sensitivity setting, EN54-7, CE according to CPD

IR95+S95ANALOGUE/ADDRESSABLE INFRARED FLAME DETECTOR, microprocessor based, 1 programmable remote alarm indicator output, EN54-10 CE according to CPD

Addressable flame detector

UNIVERSAL BASE WITH STICK ADDRESS SOCKETfor 05-range conventional and addressabledetectors

S05SE

PLUG IN ISOLATOR BOARD for 05 detectors (to be plugged in S05SE)

ICC05

SOUND05+S05

PLUG IN CONNECTION BOARD for cable ≥ 1,5mm2 (to be plugged in S05SE)

STRAPP

Universal base with GLANDS HOLE for 05range, base with tubes connections

RELAY BOARD (12V or 24V) for 05 detectors(to be plugged in S05), NO-NC 30V/1A

PROTECTION PLATE for S05 base, permits tocover a base without detector

WATERPROOF universal base with glands for05 range (IP65), base with tubes connections supplied with glands

CS05

BRI/EM+ S05

BRI + S05

ANTIVANDALISM protection grid GAV

BASE WITH INTERNAL SOUNDER 95db @ 1m,Possibility to select 6 tones and 3 intensitivitylevels, EN54-3, CE according to CPD.

R05

FLUSHMOUNTING PIECE FOR BASE (Base not included), permits to flushmount a 05range detector.

PES05

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:32 Pagina 21

Page 22: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

22

INTELLIGENT/INTERACTIVE PANELS ANDDETECTORS

DMA05ADDRESSABLE MANUAL CALL POINT resettable with key without breakingglass, integrated isolator, red colour,EN54-11, EN54-17, CE according to CPD

DMA05RADDRESSABLE MANUAL CALL POINT resettable with key without breakingglass, integrated isolator and programmable relay output, redcolour, EN54-11, EN54-17,EN54-18 CE according to CPD

AVSA05/WADDRESSABLE HIGH POWERED PIEZOELECTRIC SOUNDER for indoor use (white colour), integrated isolator, possibility to select 6 tones, 95db@1m, lateral hearings, loop powered, for HEPHAIS range

AVSA05/RADDRESSABLE HIGH POWERED PIEZOELECTRIC SOUNDER for indoor use (red colour), integrated isolator, possibility toselect 6 tones, 95db@1m, lateral hearings, loop powered, for HEPHAIS range

TRANSPARENT LIFT-UP protective cover for MCP,permits a double action

VPDM

PLASTIC FRAME for flush mounting MCPPEDM

KIT OF 10 RESET KEYS for 05 MCP KCTDM

LOOP SOUNDERS

05 range Accessories

Addressable waterproof manual call point

STS6535WATERPROOF IP65 HOUSING BOX for conventional and addressable manual call point with reset (call point not included)

ADDRESSABLE MANUAL CALL POINTS

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:32 Pagina 22

Page 23: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

23

INTELLIGENT/INTERACTIVE PANELS AND DETECTORS

INTERFACE LOOP UNITS

MAY1ADDRESSABLE ZONE INTERFACE MODULE with backbox, for max 32 conventional points

MBA95ADDRESSABLE ZONE INTERFACE MODULE with backbox, for max 32 conventional points, isolator integrated,opto-isolated on the secondary line, EN54-17, EN54-18, EN54-13 CE according to CPD

ETC05-BADDRESSABLE INPUT/OUTPUT MODULE with backbox, isolator integrated, NO or NC monitoring for input , relay output NO-NC 30V/1A, EN54-17, EN54-18 CE according to CPD (exists also in RAIL DIN version)

ET4C05-BADDRESSABLE 4 INPUT/OUTPUT MODULE with backbox, isolator integrated, NO or NC monitoring for input , relayoutput NO-NC 30V/1A, EN54-17, EN54-18 CE according to CPD

EDLADDRESSABLE 2 MONITORED INPUT + 1 MONITORED LINE OUTPUT permits to manage 2 monitored inputs anduse monitored sounders line for outputs, EN54-17, EN54-18, CE according to CPD

IAT16R/DADDRESSABLE 16 OUTPUT RELAY MODULE on rail din, relay output NO-NC 30V/1A

IAT16E/DADDRESSABLE 16 MONITORED INPUT MODULE on rail din

PROGRAMMING AND MAINTENANCE TOOL

MINIBT05Portable tool for programming / test / maintenance of detectors and addressable devices (for 05 range)

ED4LADDRESSABLE 8 MONITORED INPUT + 4 MONITORED LINE OUTPUT permits to manage 8 monitored inputs anduse monitored sounders line for outputs, EN54-17, EN54-18, CE according to CPD

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 16:21 Pagina 23

Page 24: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

24

SPECIFIC PRODUCTS GENERAL VIEW

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:33 Pagina 24

Page 25: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

25

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:33 Pagina 25

Page 26: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

LINEAR SMOKE DETECTORS

26

DLFBe IINTELLIGENT INTERACTIVE BEAM DETECTOR (loop powered) for linearsmoke detection supplied with reflectorfor distance from 3 up to 100 meters, integrated isolator, visible ray for alignment, EN54-12, CE according to CPD

DLFB Accessories

DLFBe CCONVENTIONAL BEAM DETECTOR, 2 wires(line powered) for linear smokedetection supplied with reflector for distance from 3 up to 100 meters, visible ray for alignment, EN54-12, CE according to CPD

DLFBe RRELAY BEAM DETECTOR, for linearsmoke detection supplied with reflectorfor distance from 3 up to 100 meters, NO-NC ALARM, NO-NC FAULT, visible rayfor alignment, EN54-12, CE accordingto CPD

DFA05-1C-BCONVENTIONAL SINGLE CHANNEL HIGH SENSITIVITY BASE DETECTOR for one samplingtube with smoke level indicator, to be completed with one detector module SSD,EN54-20 CE according to CPD

DFA05-2C-BCONVENTIONAL DUAL CHANNEL HIGH SENSITIVITY BASE DETECTOR , for one or twosampling tubes with smoke level indicator, to be completed with one or two detectorsmodules SSD, EN54-20 CE according to CPD

DFA05-1CINTELLIGENT/INTERACTIVE SINGLE CHANNELHIGH SENSITIVITY BASE DETECTOR , for onesampling tube, to be completed with one detector module SSD, EN54-20 CE accordingto CPD

DFA05-2CINTELLIGENT/INTERACTIVE DUAL CHANNELHIGH SENSITIVITY BASE DETECTOR , for one ortwo sampling tubes, to be completed with oneor two detectors modules SSD, EN54-20 CEaccording to CPD

WITH HIGH SENSITIVITY DETECTORS Detector modules

REMOTE CONTROL WITH DISPLAY AND KEYPADfor DLFBe, permits to adjust the alignment andprogram the beam

DETTEL

REMOTE BOX FOR BEAM, permits remotely to enable/disable, reset, can be plugged on the remote control DETTEL, 4 wires connections tothe beam

BEAM-BR

HIGH SENSITIVITY SMOKE DETECTOR MODULEwith alarm sensitivity range from 0,01%/m to10%/m to be plugged in DFA05

HIGH SENSITIVITY SMOKE DETECTOR MODULEwith alarm sensitivity range from 0,002%/m to10%/m to be plugged in DFA05

SUNSHIELD PROTECT FOR REFLECTOR, suppliedfor 4 reflectors 10x10 reflectors, permits toprotect against sun rays

BEAM-KIT4CC

RELAY INTERFACE MODULE with 5 programmablerelays, NO-NC 30V/1A to be plugged in DFA05

RIM35

SD-1GO MEMORY CARD MODULE to be pluggedin DFA05 permits to record operating data andstore memory events

MCM35

AIR SAMPLING DETECTION

SSD 535-3

SSD 535-2

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:33 Pagina 26

Page 27: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

27

AIR SAMPLING DETECTION

SAMPLING PIPE CONFIGSYSTEM DESIGN SOFTWARE permits to define the network pipe

DFA05 CONFIGPROGRAMMING SOFTWARE permits to download/upload data configuration through USB cable (not supplied)

PROGRAMMING SOFTWARE FOR DFA05

TP2SFIRE LOCALISATION DEVICE HEAD ,this device connected to aspiratingpipe with high sensitive detector(DFA05) permits to address the airsampling point(s). Detector withdouble detection, led integrated P65.To be completed with SP2S

SP2SFILE LOCALISATION DEVICE BASE forwire connection to the fire alarm paneland connection for the aspiratingtype.IP65.To be completed with TP2S

FIRE LOCALISATION DEVICE Options

RELAY BOARD (12V or 24V) for 05 detectors (to be plugged in S05), NO-NC 30V/1A

R05

Filter mat-SFilter Mat Small for FBS 25 PC

FBL 25PCFilter Box Large Ø 25 mm, PC

FBS 25PCFilter Box Small Ø 25 mm, PC

Filter mat-LFilter Mat Small for FBS 25 PC

MV 25 ABSManual ball valve Ø 25 mm, ABS

FILTERS

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:34 Pagina 27

Page 28: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

28

ASPIRATING PIPES

AIR SAMPLING DETECTION

TU25RFFIREPROOF AIR SAMPLING PIPE 25mm(3m length), red colour (Qmin =30)

EN25RFFIREPROOF STRAIGHT SOCKET 25mm,red colour, (Qmin =20)

TE25RFFIREPROOF EQUAL TEE PIECE for 25mmtube, red colour, (Qmin =10)

T 25/8FIREPROOF EQUAL TEE PIECE for 8mmcapillary tube or sample point, red co-lour, (Qmin =10)

TT25RFFIREPROOF END CAP, for 25mm tube ,red colour, (Qmin =10)

C90RFFIRE PROOF 90° ELBOW, for 25mm tube,red colour, (Qmin =5)

CF70FLEXIBLE ELBOW for 25mm tube,(Qmin =4)

C45RFFIRE PROOF 45° ELBOW, for 25mm tube,red colour, (Qmin =5)

TF.10FLEXIBLE TUBE 1m length

TC.8CAPILLARY TUBE (10mm OD; 8mm ID)(100m roll)

ABRFIRE PROOF PIPE CLIP for 25mm tube, redcolour, (Qmin =50)

UTRFFIREPROOF UNION TUBE for 25mm tube, redcolour, (Qmin =10)

PMTUSAMPLE POINT 8mm

PMCCONIC SAMPLE POINT, (Qmin =10)

PMPTPLATE SAMPLE POINT vith nut, (Qmin =10)

PMPPLATE SAMPLE POINT vith screws, (Qmin =10)

PMC/8SAMPLE POINT for capillary tube, (Qmin =10)

PCM/10RAISE FOR CLIP , raises for 17mm, (Qmin =10)

PRPMEXTENSION LEAD for sample point, (Qmin =10)

TLWATERPROOF ENDCAP, (Qmin =10)

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:35 Pagina 28

Page 29: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

29

EXPLOSION HAZARD AREA PRODUCTS

VTEXCONVENTIONAL RATE OF RISE + FIXED HEAT DETECTOR, Ex version, ATEX II 1G Eex ia IIC T6, EN54-5

SVEXMOUNTING BASE- anti-static design - Ex version

DMEXCONVENTIONAL MANUAL CALL POINT with reset key , Ex version

AVSEXINTRISICALLY SAFE SOUNDER-EX- 100db, to be used with SBEX BZ3

MBA95ExADDRESSABLE ZONE INTRISICALLY INTERFACE MODULE with backbox, for max 10 conventional EEX points, isolatorintegrated, opto-isolated on the secondary line, EN54-17, EN54-18, EN54-13 CE according to CPD

SBEX BZ1SAFETY BARRIER dedicated for intrisically safe detectors and call points

SBEX BZ3SAFETY BARRIER dedicated exclusively for intrisically safe sounders

VIREXCONVENTIONAL INFRARED FLAME DETECTOR - Ex version, ATEX II 1G Eex ia IIC T6, EN54-10

VOEXCONVENTIONAL OPTICAL SMOKE DETECTOR - Ex version, ATEX II 1G Eex ia IIC T6 EN54-7

SBEX BZ2SAFETY BARRIER dedicated for intrisically safe detectors and call points, opto-isolated

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:35 Pagina 29

Page 30: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

30

WIRELESS SOLUTIONS

OA05-WWIRELESS OPTICAL SMOKE DETECTOR, 1 remote led output, EN54-7 , EN54-25, CE according to CPD

DMA05-WWIRELESS MANUAL CALL POINT, EN54-11 , EN54-25, CE according to CPD

OI05MONITORING MODULE can be connected on HEPHAIS 1600 ,1 remote led output, monitoring device of wireless equipments EN54-17, EN54-18, EN54-25, CE according to CPD

TELEWIRELESSSOFTWARE PROGRAMMING TOOL for WIRELESS SOLUTIONS

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:35 Pagina 30

Page 31: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

31

ACCESSORIES FOR FIRE SYSTEMS

IND05REMOTE ALARM INDICATOR angle of vision = 180°

AVS 2000/WHIGH POWERED PIEZOELECTRIC SOUNDER for INDOOR use (white colour), possibility to select 6 tones, lateralhearings, 95db@1m, EN54-3 according to CPD

AVS 2000/RHIGH POWERED PIEZOELECTRIC SOUNDER for INDOOR use (red colour), possibility to select 6 tones, 95db@1m,lateral hearings, EN54-3 according to CPD

AVSU EFPHIGH POWERED PIEZOELECTRIC SOUNDER for OUTDOOR , 114db@1m, IP65, EN 54-3 according to CPD

AVS2000FLASHCOMBINED SOUNDER AND FLASH for INDOOR use, 95db@1m, EN54-3 according to CPD

AVSFLASHXENON BEACON high luminosity with 360° angle ,from 12Vdc to 48Vdc

4485COMBINED SOUNDER AND FLASH for OUTDOOR use (red colour), IP65, 101db@1m, EN54-3 according to CPD

531024-1019XENON OUTDOOR BEACON high luminosity with 360° angle ,from 9Vdc to 60Vcc, IP65

P7232OPTICAL ACOUSTIC ALARM PANEL WITHBUZZER lighting with high luminosity LED,12V/24Vdc, IP55

P7236SELF-POWERED OPTICAL ACOUSTIC ALARM PANEL WITHBUZZER lighting with high luminosity LED, 12V/24Vdc,IP55

IND05EWATERPROOF REMOTE ALARM INDICATOR angle of vision = 180°

P7264OPTICAL ACOUSTIC ALARM PANEL WITHSOUNDER, lighting with high luminosity LEDIP55

P7265OPTICAL ACOUSTIC ALARM PANEL WITH SOUNDER, lighting with high luminosity LED, 12V/24Vdc, IP43

P7260OPTICAL ACOUSTIC ALARM PANEL WITH SOUNDER, lighting with high luminosity LED, 12V/24Vdc, IP65

P7266SELF-POWERED OPTICAL ACOUSTIC ALARM PANEL WITHSOUNDER, lighting with high luminosity LED IP55

S/EKO F24SELF POWERED OUTDOOR SOUNDER WITH FLASH, IP34, 24 Vdc

P7268SELF-POWERED OPTICAL ACOUSTIC ALARM PANEL WITH SOUNDER, lighting with high luminosity LED IP43

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:36 Pagina 31

Page 32: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

ACCESSORIES FOR FIRE SYSTEMS

32

ALTO-DA1B00XINFORMATION AND DIRECTION LIGHTING, IP40, sustained double sided 3 hours, wall mounted (exists also ceilingmounted) , operating voltage 230VAC/50hz, IP40

MARINA-DA3B0XEMERGENCY LIGHT NON-MAINTAINED SINGLE SIDED 3 hours (exists also in sustained), IP65, operating voltage230VAC/50HZ

FENER-2210107XEMERGENCY LIGHT 1 hour (exists also in 3 hours), 2 halogen lamps 20W (exists also with 1), 12V 7Ah battery

VTR0241210ELECTROMAGNETIC DOOR release unit in metal case, 50daN, 24V

1360ELECTROMAGNETIC DOOR release unit in metal case, 100daN, 24V

1388AELECTROMAGNETIC DOOR release unit in metal case, 300kg/250daN, 24V

1450FLOODING AND MOISTURE DETECTOR with free voltage contact relay, 12/24Vdc

2450IP 67 LIQUID DETECTOR with free voltage contact relay, 12/24Vdc

DA4PHONE DIALER with 4 inputs and 4 voice messages

GSM 31 GPRSGSM/GPRS communicator (with metal enclosure, GSM antenna and power supply)

USB/232CONVERTER MODULE USB/232

4476-24RED INTERNAL BELL, diameter 150mm, 93 db, 24Vdc

4479-24RED EXTERNAL BELL, 6 inches diameter ,93 db, 24Vdc

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:36 Pagina 32

Page 33: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

33

MONITORING SOFTWARE

JBUS/IPTCPIP INTERFACE for analogue panels (MA53 422/232converter + Procontroller 232/TCPIP converter)

JBUS/IP/4TCPIP interface for 4 analogue panels (MA53 422/232converter + Procontroller 232/TCPIP converter)

MA53CONVERTER MODULE RS232/RS422 with power supply

CONCUFICONVERTER MODULE RS422/RS485/RS232 to optic fiber max distance 6km, multimode, rail din enclosure, 7Vdc to60Vdc power

MAPSKITALPHA-HEPHAISBASE REMOTE MAP MONITORING SOFTWARE for 8 panels(to be completed with MAPSPLUS),compatible with addressableALPHA 500/1000 or HEPHAIS 1600 panels

NET VERSION BASE REMOTE MAP MONITORING SOFTWARE (to be completed with MAPSPLUSALPHANET),compatible with addressableALPHA 500/1000 or HEPHAIS 1600 panels

MAPSKITALPHA-HEPHAIS NET

MAPSKITALPHA-HEPHAIS Options

NET VERSION ADDITIONAL LICENSE for management of 1 panel,compatible with addressable ALPHA 500/1000 or HEPHAIS 1600 panels

MAPSPLUSALPHA-HEPHAIS NET

ADDITIONAL LICENSE for 1 panel management, compatiblewith addressable ALPHA 500/1000 or HEPHAIS 1600 panels

MAPSPLUSALPHA-HEPHAIS

NET VERSION ADDITIONAL LICENSE for management of 4 panels,compatible with addressable ALPHA 500/1000 or HEPHAIS 1600panels

MAPSPLUSALPHA-HEPHAIS NET4

CONVERTERS

Optic fiber converter

Serial converter

MAPSKITALPHA-HEPHAIS FOR NETWORK Options

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:37 Pagina 33

Page 34: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

HEPHEA POWER SUPPLY RANGE

34

RACK VERSION

HEPHEA 242POWER SUPPLY IN BOX 24V-2A, including output relays for mains fault and battery fault, metallic box405x385x160mm, EN54-4 (A2), CE according to CPD

HEPHEA 244POWER SUPPLY IN BOX 24V-4A, including output relays for mains fault and battery fault, metallic box405x385x160mm, EN54-4 (A2), CE according to CPD

AL124H-CP01POWER SUPPLY IN PLASTIC BOX 24V-1A, including output relays for mains fault and battery fault

AL424H-CM01EPOWER SUPPLY IN METALLIC BOX 24V-4A, 265x405x140mm, including output relays for mains fault and battery fault

AU224/A2/RPOWER SUPPLY IN RACK VERSION 24V-2A, including output relays for mains fault and battery fault, 19inches, 3U

AU424/A2/RPOWER SUPPLY IN RACK VERSION 24V-4A, including output relays for mains fault and battery fault, 19inches, 3U

AL1024B-CM03POWER SUPPLY IN METALLIC BOX 24V-10A, 405x390x165mm, including output relays for mains fault and batteryfault

HEPHEA 248POWER SUPPLY IN BOX 24V-8A, including output relays for mains fault and battery fault, metallic box405x385x160mm, EN54-4 (A2), CE according to CPD

HEPHEA 2412POWER SUPPLY IN BOX 24V-12A, including output relays for mains fault and battery fault, metallic box405x385x160mm, EN54-4 (A2), CE according to CPD

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:37 Pagina 34

Page 35: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

35

GAS DETECTION

GD104CCONVENTIONAL HYDROGENE GAS DETECTOR, H2, IP55, alarm and prealarm resistors integrated, needs external power supply

GD105CCONVENTIONAL LIQUID PROPANE GAS DETECTOR, LPG, IP55, alarm and prealarmresistors integrated, needs external powersupply

METHANE GAS TEST BOTTLE , 40% L.I.E, 12 litersMEGAS

GD100CCONVENTIONAL METHANE GAS DETECTOR,CH4, IP55, can be directly connected onALPHA panel, alarm and prealarm resistors integrated, needs external power supply

GD102CCONVENTIONAL PETROL STEAM GAS DETECTOR, IP55, can be directly connectedon ALPHA panel, alarm and prealarm resistors integrated, needs external power supply

TEST KIT GAS DETECTORS (valve + adapter)P7150V

PLUG-IN 3 RELAY CARD, NO-NC 30V/1A , to beplugged inside the detector, permits to repeatALARM, PREALARM, FAULT of the detector

GDREL

CONVENTIONAL GAS DETECTORS Accessories

REMOTE CONTROL WITH DISPLAY AND KEYPADfor GAS DETECTORS, permits to read level anddata of detectors (sensitivity, thresholds…)

DETTEL

CARBON MONOXIDE GAS TEST BOTTLE, 250ppm,12 liters

COGASGD106CCONVENTIONAL PROPANE GAS DETECTOR,C3H8, IP55, alarm and prealarm resistors integrated, needs external power supply

GD109CCONVENTIONAL ACETILENE GAS DETECTOR,C2H2, IP55, alarm and prealarm resistors integrated, needs external power supply

PETROL STEAM GAS TEST BOTTLE , 40% L.I.E, 12 liters

VPGAS

GD113CCONVENTIONAL CARBON MONOXIDE GASDETECTOR, CO, IP55, ELECTROCHEMICALCELL, alarm and prealarm resistors integrated,needs external power supply

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:42 Pagina 35

Page 36: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

GAS DETECTION

36

ADDRESSABLE GAS DETECTORS Accessories

GD100AADDRESSABLE METHANE GAS DETECTOR,CH4, IP55, can be directly connected on HEPHAIS loops, integrated isolator, needs external power supply

CARBON MONOXID GAS TEST BOTTLE, 250ppm,12 liters

COGAS

GD102AADDRESSABLE PETROL STEAM GAS DETECTOR, IP55, can be directly connectedon HEPHAIS loops, integrated isolator, needsexternal power supply

PETROL STEAM GAS TEST BOTTLE , 40% L.I.E, 12 liters

VPGAS

METHANE GAS TEST BOTTLE , 40% L.I.E, 12 litersMEGASGD104AADDRESSABLE HYDROGENE GAS DETECTOR,H2, IP55, can be directly connected on HEPHAIS loops, integrated isolator, needs external power supply

GD105AADDRESSABLE LIQUID PROPANE GAS DETECTOR, LPG, IP55, can be directly connected on HEPHAIS loops, integrated isolator, needs external power supply

GD106AADDRESSABLE PROPANE GAS DETECTOR,C3H8, IP55, can be directly connected on HEPHAIS loops, integrated isolator, needs external power supply

GD109AADDRESSABLE ACETILENE GAS DETECTOR,C2H2, IP55, can be directly connected on HEPHAIS loops, integrated isolator, needs external power supply

TEST KIT GAS DETECTORS (valve + adapter)P7150V

REMOTE CONTROL WITH DISPLAY AND KEYPADfor GAS DETECTORS, permits to read the leveland data of the detector (sensitivity, thresholds…)

DETTEL

GD113AADDRESSABLE CARBON MONOXIDE GAS DETECTOR, CO, IP55, ELECTROCHEMICALCELL, can be directly connected on HEPHAISloops, integrated isolator, needs externalpower supply

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:43 Pagina 36

Page 37: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

37

GAS DETECTION

SD2243GPExd LPG GAS DETECTOR, 0-100% LEL,εx 2GD Ex d IIC T6 Ex tD A21 IP65

T 85°C

SD2243H2Exd HYDROGEN GAS DETECTOR, 0-100% LEL, εx 2GD Ex d IIC T6 Ex tDA21 IP65 T 85°C

SD2243MEExd METHANE GAS DETECTOR, 0-100%LEL, εx 2GD Ex d IIC T6 Ex tD A21 IP65 T 85°C

Calibration adapterZMCAP

SD2243VBExd PETROL STEAM GAS DETECTOR, 0-100% LEL, εx 2GD Ex d IIC T6 Ex tDA21 IP65 T 85°C

SD2243BUExd BUTANE GAS DETECTOR, 0-100%LEL, εx 2GD Ex d IIC T6 Ex tD A21 IP65 T 85°C

Calibration keypad to adjust the detector zeroand span values

STS/CKD

PLUG-IN 3 RELAY CARD, NO-NC 30V/1A , to beplugged inside the detector, permits to repeatALARM, PREALARM, FAULT of the detector

STS3REL

SD2243PRExd PROPANE GAS DETECTOR, 0-100%LEL, εx 2GD Ex d IIC T6 Ex tD A21 IP65T 85°C

Flammable gas Accessories

SD2244AMExd AMMONIAC GAS DETECTOR, 0-100% LEL, εx 2GD Ex d IIC T6 Ex tDA21 IP65 T 85°C

Toxic gas

SD2245O2Exd OXYGEN GAS DETECTOR, 0-200ppm, εx 2GD Ex d IIC T6 IP65

SD2246AMExd AMMONIAC GAS DETECTOR, 0-200ppm, εx 2GD Ex d IIC T6 IP65

SD2247AMExd AMMONIAC GAS DETECTOR, 0-1000ppm, εx 2GD Ex d IIC T6 IP65

EXPLOSION PROOF GAS DETECTION

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:44 Pagina 37

Page 38: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

MARINE

38

ADDRESSABLE PANELS

HEPHAIS 128-MINTELLIGENT/INTERACTIVE COMPACT CONTROL PANEL, 128 ADDRESSES, 2 loops or 4 spur circuits (open circuit withmax 32 addresses), 99 ZONES, 1000 memory events, 1 monitored sounders line + 5 programmable output relays,1xRS232 serial output for printer or remote control panel, 2 programmable inputs. The panel can be set by keyboard or software. Needs 2 internal batteries 12V/7Ah. EN54-2, EN54-4, CE according to CPD, Marine Bureau veritas approved

From 1 to 1600 addresses

HEPHAIS 1600-400/LPM-MMODULAR INTELLIGENT/INTERACTIVE FIRE CONTROL PANEL MAX 1600 POINTS, 10 LOOPS - supplied as standard for400 points on 2 loops (max 200 addresses/loop) or 4 spur circuits, EN54-2, EN 54-4, in large metallic box withintegrated front panel, 1000 Zones, 2700 memory events, 2 monitored sounders lines + 3 programmableoutput relays, 1xRS232 serial output for printer and 1xRS485 serial output for remote control panel, 4 programmable inputs, RS422 JBUS monitoring output , networkable with MGNET board. Needs 2 internal batteries12V/17Ah. EN54-2, EN54-4, CE according to CPD, Marine Bureau veritas approved

From 1 to 128 addresses

ADDRESSABLE DETECTORS

OA05-MINTELLIGENT/INTERACTIVE OPTICAL SMOKE DETECTOR, microprocessor based , 1 programmable remotealarm indicator output, 8 levels sensitivity setting, EN54-7 edition 2000, CE according to CPD, Marine Bureau veritas approved

TA05-MINTELLIGENT/INTERACTIVE HEAT DETECTOR, static or/and rate of rise, microprocessor based , 1 programmableremote alarm indicator output, 6 levels sensitivity setting, EN54-5 edition 2000, CE according to CPD, Marine Bureau veritas approved

UNIVERSAL BASE WITH STICK ADDRESS SOCKET for 05-range conventional and addressable detectors

S05SE

WATERPROOF universal base with glands for 05 range (IP65), base with tubes connections supplied with glands

DMA05-MADDRESSABLE MANUAL CALL POINT - resettable with key without breaking glass, integrated isolator, red colour,EN54-11, EN54-17, CE according to CPD, Marine Bureau veritas approved

MBA95-MADDRESSABLE ZONE INTERFACE MODULE with backbox, for max 32 conventional points, isolator integrated, opto-isolated onthe secondary line, EN54-17, EN54-18, EN54-13 CE according to CPD, Marine Bureau veritas approved

BRI + S05

PLUG IN ISOLATOR BOARD for 05 detectors (to be plugged in S05SE)ICC05

ETC05-B-MADDRESSABLE INPUT/OUTPUT MODULE with backbox, isolator integrated, NO or NC monitoring for input , relay output NO-NC30V/1A, EN54-17, EN54-18 CE according to CPD (exists also in RAIL DIN version), Marine Bureau veritas approved

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:44 Pagina 38

Page 39: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

39

VOICE EVACUATION SYSTEMS

SEV-CVOICE EVACUATION CENTRAL PANEL, manages max 8 speakers, connected to monitored sounder lineor relay contact, needs 24Vdc external power supply, 30s of message + 4s of sound of sounder

SPEAKERS

STR50SATELLITE SPEAKER 105db, max 8 per line

STR44SATELLITE SPEAKER 115db, max 8 per line

SNR35SATELLITE SPEAKER 125db, max 4 per line

VOICE SOUNDERS

DSV110/WHIGH POWERED VOICE SOUNDER 100db@1m, (8s message), white colour, can be directly connected on sounderlines

PROG DSV 110BOARD FOR programming the voice message

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:45 Pagina 39

Page 40: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

ELECTRIC LOCK FOREMERGENCY EXIT DOORS

40

DS3000ELECTRIC LOCK FOR EMERGENCY exit doors with single action

DS3000 2VTXELECTRIC LOCK FOR EMERGENCY exit doors with double actions

CLEVLOCAL COMMAND of evacuation with key

FIRE ALARM CABLE

S-3ANT20502x0,5 mm2 (diam 0,8) cable , twisted with screen, polyvinylchloride rated , flame retardant, red colored (rolls by200m)

S-3ANT20102x1,00 mm2 cable , twisted with screen, polyvinylchloride rated , flame retardant, red colored (rolls by 200m)

FIRE PROOF CABLE

S-AFU20152x1,5 mm2 cable ,insulated with flame barrier, fire resistant 750°C according to IEC60331, red colored (rolls by200m)

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:45 Pagina 40

Page 41: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

41

MAINTENANCE EQUIPMENT

3010Smoke detector tester

3015Aerosol bottle of 250 ml (pack of 12)

3053Heat detector tester (head and 12V controller)

305912V charger

406505 removal tool

405195 removal tool

2001Telescopic access pole 2x1.50m

2002Telescopic access pole 2x2.00m

Telescopic access Accessories

2.00m extension1005

1.50m extension1004

1.00m extension1001

TEST AND MOUNTING TOOLS

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:45 Pagina 41

Page 42: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

MAINTENANCE EQUIPMENT

42

SPARE PARTS

AL2BOARDALPHA 2 MOTHER BOARD

Alpha 4/8/12

AR4DALPHA 4/8/12 MOTHER BOARD

Hephais 128

MP128HEPHAIS 128 MOTHER BOARD

Hephais 1600 NE

MB2BPANEL’S MAIN CPU BOARD

MB2B NEPANEL’S MAIN CPU BOARD

ALBA150POWER SUPPLY FOR HEPHAIS 1600

Alpha 2

Hephais 1600

ALBA150POWER SUPPLY FOR HEPHAIS 1600

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:46 Pagina 42

Page 43: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

43

MAINTENANCE EQUIPMENT

Alpha 500/1000

CPUBCPU board for alpha 500/1000

ALBAPOWER supply for ALPHA 500/1000

MD1B05Extension module for 4 spur circuits (max 32 points per circuit) or 2 loops (max 125 points), for 05 intelligent detectors range

MD1BExtension module for 4 spur circuits (max 32 points per circuit) or 2 loops (max 125 points), for 95 detectors range

ESAL D 3UUser interface panel with alphanumeric display 160 characters and keyboard, rack mount version 19", for ALPHA 500/1000

OA95Analogue/addressable optical smoke detector, EN54-7

95 serie detectors

TVA95Analogue/addressable rate of rise + fixed heat detector, EN54-5

TPA95Analogue/addressable fixed heat detector, EN54-5

OTA95Analogue/addressable multicriteria (optical-heat) detector EN54-7

S95Universal base for conventional and analogue detectors

DLFB AADDRESSABLE BEAM DETECTOR (loop powered) for linear smoke detection supplied with reflector for distance from 3 up to 100 meters,integrated isolator,visible ray for alignment, EN54-12, for ALPHA 500/1000 panels

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:47 Pagina 43

Page 44: lg6 SD3inglese catalogo2011:lg6 SD3inglese catalogo2011 16 ...denasanat.com/wp-content/uploads/2013/07/SD3-Catalogue.pdf · lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011

lg6_SD3inglese_catalogo2011:lg6_SD3inglese_catalogo2011 16-02-2011 12:47 Pagina 44