www.tridonic.com 1 Subject to change without notice. Data sheet 09/14-LC149-0 LED control gear Linear / area fixed output Product description • Fixed output constant current built-in LED control gear • Output current 250, 300 or 350 mA • Max. output power 65 W • Nominal life-time up to 50,000 h • For class I luminaires • 5-year guarantee Properties • Low-profile metal casing with white cover • Type of protection IP20 Functions • Intelligent Temperature Guard (overtemperature protection) • Short-circuit proof • Overload protection È Standards, page 3 Uconverter LCI 65W 250/300/350mA TEC lp TEC series
7

L · LCI 65W 250mA TEC lp tc Ø4,1 4,1 30 5 21 6 280 270 side fixing feature 15 72 LCI 65W 300mA TEC lp + LCI 65W 350mA TEC lp Ordering data Type Article number Packaging carton

Nov 09, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: L · LCI 65W 250mA TEC lp tc Ø4,1 4,1 30 5 21 6 280 270 side fixing feature 15 72 LCI 65W 300mA TEC lp + LCI 65W 350mA TEC lp Ordering data Type Article number Packaging carton

www.tridonic.com 1Subject to change without notice.

Data sheet 09/14-LC149-0

LED control gearLinear / area fixed output

Product description

•Fixedoutputconstantcurrentbuilt-inLEDcontrolgear

•Outputcurrent250,300or350mA

•Max.outputpower65W

•Nominallife-timeupto50,000h

•ForclassIluminaires

•5-yearguarantee

Properties

•Low-profilemetalcasingwithwhitecover

•TypeofprotectionIP20

Functions

• IntelligentTemperatureGuard(overtemperatureprotection)

•Short-circuitproof

•Overloadprotection

ÈStandards,page3

Uconverter LCI 65W 250/300/350mA TEC lpTECseries

Page 2: L · LCI 65W 250mA TEC lp tc Ø4,1 4,1 30 5 21 6 280 270 side fixing feature 15 72 LCI 65W 300mA TEC lp + LCI 65W 350mA TEC lp Ordering data Type Article number Packaging carton

www.tridonic.com 2Subject to change without notice.

Data sheet 09/14-LC149-0

LED control gearLinear / area fixed output

Specific technical dataType Output

currentMin.outputvoltage

Max.outputvoltage

Max.outputpower

Inputpower(at230V,50Hz,fullload)

Inputcurrent(at230V,50Hz,fullload)

Efficiency(at230V,50Hz,fullload)

Max.repetitiveoutputpeakcurrent

Max.non-repetitiveoutputpeakcurrent

tcpoint

LCI 65W 250mA TEC lp 250mA 112V 250V 62.5W 67.5W 305mA 93% 300mA 337.5mA 65°C

LCI 65W 300mA TEC lp 300mA 97V 217V 65.0W 70.5W 320mA 92% 360mA 405.0mA 70°C

LCI 65W 350mA TEC lp 350mA 83V 186V 65.0W 70.5W 320mA 92% 420mA 472.5mA 70°C

Technical dataRatedsupplyvoltage 220–240V

Inputvoltage,AC 198–264V

Mainsfrequency 50/60Hz

λ(at230V,50Hz,fullload) 0.98

Leakagecurrent(PE) <0.5mA

THD(at230V,50Hz,fullload) <20%

Outputcurrenttolerance ±7.5%

Outputcurrentripple ±15%

Max.outputvoltage(no-loadvoltage) 250V

Timetolight <0.5s

Ambienttemperatureta -20...+50°C

DimensionsLxWxH 280x30x21mm

Uconverter LCI 65W 250/300/350mA TEC lpTECseries

Ø4,1

4,1

30

215

6

280

270

side fixing feature

15

117

tc

LCI65W250mATEClp

tc

Ø4,1

4,1

30

215

6

280

270

side fixing feature

15

72

LCI65W300mATEClp+LCI65W350mATEClp

Ordering data

Type Article number Packagingcarton

Packaging,lowvolume

Packaging,highvolume

Weightperpc.

LCI 65W 250mA TEC lp 87500325 50pc(s). 900pc(s). 2,700pc(s). 0.186kg

LCI 65W 300mA TEC lp 87500326 50pc(s). 900pc(s). 2,700pc(s). 0.186kg

LCI 65W 350mA TEC lp 87500327 50pc(s). 900pc(s). 2,700pc(s). 0.186kg

Page 3: L · LCI 65W 250mA TEC lp tc Ø4,1 4,1 30 5 21 6 280 270 side fixing feature 15 72 LCI 65W 300mA TEC lp + LCI 65W 350mA TEC lp Ordering data Type Article number Packaging carton

www.tridonic.com 3Subject to change without notice.

Data sheet 09/14-LC149-0

LED control gearLinear / area fixed output

StandardsEN55015EN61000-3-2EN61000-3-3EN61347-2-13EN62384EN61547

Humidity: 5%uptomax.85%, notcondensed (max.56days/yearat85%)

Storagetemperature:-40°Cuptomax.+80°C

Thedeviceshavetobewithinthespecifiedtemperaturerange(ta)beforetheycanbeoperated.

Overload protectionLEDcontrolgearwillswitchoffatoverloadoperation.MainsresetisrequiredtorestarttheLEDcontrolgear.

Overtemperature protectionTheLEDcontrolgearwillreduceoutputcurrentattemporarythermalover-heating(exceedingmax.tcpoint).

Short-circuit behaviourLEDcontrolgearwillswitchoffincaseofshort-circuitofLEDoutput.MainsresetisrequiredtorestarttheLEDcontrolgear.

No-load operation or load loss during operationLEDcontrolgearwilldetectaloadlossduringoperation.Inthiscaseandno-loadoperationthemax.outputvoltagecanapplyattheLEDoutputformax.5sbeforeLEDcontrolgearshutsdown.MainsresetisrequiredtorestarttheLEDcontrolgear.

Temperature rangeTheLEDcontrolgearlifedurationisrelatedtotheambienttemperatureta.Therelationoftctotatemperaturedependsalsoontheluminairedesign.Ifthemeasuredtctemperatureisapprox.5Kbelowtcmax.orhigher,tatemperatureshouldbecheckedandeventuallycriticalcomponents(e.g.ELCAP)measured.Detailedinformationonrequest.

Expected life-timeType ta 40 °C 50 °C 60 °C

LCI 65W 250mA TEC lptc 55°C 65°C xlife-time 50,000h 30,000h x

LCI 65W 300mA TEC lptc 60°C 70°C xlife-time 50,000h 30,000h x

LCI 65W 350mA TEC lptc 60°C 70°C xlife-time 50,000h 30,000h x

x=notpermitted

Page 4: L · LCI 65W 250mA TEC lp tc Ø4,1 4,1 30 5 21 6 280 270 side fixing feature 15 72 LCI 65W 300mA TEC lp + LCI 65W 350mA TEC lp Ordering data Type Article number Packaging carton

www.tridonic.com 4Subject to change without notice.

Data sheet 09/14-LC149-0

LED control gearLinear / area fixed output

Isolation and electric strength testing of luminairesElectronicdevicescanbedamagedbyhighvoltage.Thishastobeconsideredduringtheroutinetestingoftheluminairesinproduction.

AccordingtoIEC60598-1AnnexQ(informativeonly!)orENEC303-AnnexA,eachluminaireshouldbesubmittedtoanisolationtestwith500VDCfor1second.Thistestvoltageshouldbeconnectedbetweentheinterconnectedphaseandneutralterminalsandtheearthterminal.Theisolationresistancemustbeatleast2MΩ.

Asanalternative,IEC60598-1AnnexQdescribesatestoftheelectricalstrengthwith1500VAC(or1.414x1500VDC).Toavoiddamagetotheelectronicdevicesthistestmustnotbeconducted.

Additional information

Additionaltechnicalinformationatwww.tridonic.com→TechnicalData

Guaranteeconditionsatwww.tridonic.com→Services

Nowarrantyifdevicewasopened.

Maximum loading of automatic circuit breakers

Automaticcircuitbreakertype C10 C13 C16 C20 B10 B13 B16 B20 Inrushcurrent

InstallationØ 1,5mm2 1,5mm2 2,5mm2 2,5mm2 1,5mm2 1,5mm2 2,5mm2 2,5mm2 Imax time

LCI 65W 250mA TEC lp 12 18 24 28 6 9 12 14 34.9A 233μs

LCI 65W 300mA TEC lp 12 18 24 28 6 9 12 14 34.9A 233μs

LCI 65W 350mA TEC lp 12 18 24 28 6 9 12 14 34.9A 233μs

Installation instructions

Wiring type and cross sectionSolidwirewithacrosssectionof0.5–1.5mm².Strip8–9mmofinsulationfromthecablestoensureperfectoperationofterminals.

8–9mm

wirepreparation:0.5–1.5mm²

Release of the wiringLoosenwirethroughtwistingandpullingorusingaØ1mmreleasetool.

Wiring guidelines•AllconnectionsmustbekeptasshortaspossibletoensuregoodEMIbehaviour.

•MainsleadsshouldbekeptapartfromLEDcontrolgearandotherleads (ideally5–10cmdistance)•Max.lengthofoutputandIselwiresis2m.•Secondaryswitchingisnotpermitted.•IncorrectwiringcandamageLEDmodules.•Thewiringmustbeprotectedagainstshortcircuitstoearth (sharpedgedmetalparts,metalcableclips,louver,etc.).

Circuit diagram

Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in %THD 3. 5. 7. 9. 11.

LCI 65W 250mA TEC lp <20 <11 <4 <3 <2 <2LCI 65W 300mA TEC lp <20 <11 <4 <3 <2 <2LCI 65W 350mA TEC lp <20 <10 <4 <3 <2 <2

SEC

PRI

220–240 V

LN

50/60 Hz

+ LED– LED

Side fixing feature

ScrewM4,screwheaddiameter8–10mm

Page 5: L · LCI 65W 250mA TEC lp tc Ø4,1 4,1 30 5 21 6 280 270 side fixing feature 15 72 LCI 65W 300mA TEC lp + LCI 65W 350mA TEC lp Ordering data Type Article number Packaging carton

www.tridonic.com 5Subject to change without notice.

Data sheet 09/14-LC149-0

LED control gearLinear / area fixed output

THDvsload

0

4

2

8

18

45 80 85 90 9565 70 7550 55 60 100

16

14

12

10

6

Load [%]

THD

Efficiencyvsload

89,590,090,591,091,592,092,5

93,093,594,0

45 70 75 80 85 90 9550 55 60 65 100

94,5

Load [%]

Eci

ency

[%]

Powerfactorvsload

Diagrams LCI 65W 250mA TEC lp

0,89

0,90

0,91

0,92

0,94

0,96

0,95

0,93

0,97

45 70 75 80 85 90 9550 55 60 65 100

Load [%]

Pow

er fa

ctor

Inputpowervsload

0

10

50

70

45 80 85 90 9565 70 7550 55 60 100

60

20

30

40

Load [%]

Inpu

t pow

er [W

]

Inputcurrentvsload

0

150

50

250

350

45 80 85 90 9565 70 7550 55 60 100

300

200

100

Load [%]

Inpu

t cur

rent

[mA]

Page 6: L · LCI 65W 250mA TEC lp tc Ø4,1 4,1 30 5 21 6 280 270 side fixing feature 15 72 LCI 65W 300mA TEC lp + LCI 65W 350mA TEC lp Ordering data Type Article number Packaging carton

www.tridonic.com 6Subject to change without notice.

Data sheet 09/14-LC149-0

LED control gearLinear / area fixed output

THDvsload

0

4

2

8

16

45 80 85 90 9565 70 7550 55 60 100

14

10

12

6

Load [%]

THD

Efficiencyvsload

88,0

89,089,5

88,5

90,090,591,091,592,092,593,093,5

45 70 75 80 85 90 9550 55 60 65 100

94,0

Load [%]

Eci

ency

[%]

Powerfactorvsload

Diagrams LCI 65W 300mA TEC lp

0,89

0,90

0,91

0,92

0,93

0,95

0,96

0,97

0,94

0,98

45 70 75 80 85 90 9550 55 60 65 100

Load [%]

Pow

er fa

ctor

Inputpowervsload

0

10

50

80

45 80 85 90 9565 70 7550 55 60 100

60

70

20

30

40

Load [%]

Inpu

t pow

er [W

]

Inputcurrentvsload

0

150

50

250

350

45 80 85 90 9565 70 7550 55 60 100

300

200

100

Load [%]

Inpu

t cur

rent

[mA]

Page 7: L · LCI 65W 250mA TEC lp tc Ø4,1 4,1 30 5 21 6 280 270 side fixing feature 15 72 LCI 65W 300mA TEC lp + LCI 65W 350mA TEC lp Ordering data Type Article number Packaging carton

www.tridonic.com 7Subject to change without notice.

Data sheet 09/14-LC149-0

LED control gearLinear / area fixed output

THDvsload

0

4

2

8

16

45 80 85 90 9565 70 7550 55 60 100

10

12

14

6

Load [%]

THD

Efficiencyvsload

88,088,589,089,590,090,591,091,592,092,593,0

45 70 75 80 85 90 9550 55 60 65 100

93,5

Load [%]

Eci

ency

[%]

Powerfactorvsload

Diagrams LCI 65W 350mA TEC lp

0,90

0,91

0,92

0,93

0,94

0,96

0,97

0,95

0,98

45 70 75 80 85 90 9550 55 60 65 100

Load [%]

Pow

er fa

ctor

Inputpowervsload

0

10

40

80

45 80 85 90 9565 70 7550 55 60 100

50

60

70

20

30

Load [%]

Inpu

t pow

er [W

]

Inputcurrentvsload

0

150

50

250

350

45 80 85 90 9565 70 7550 55 60 100

300

200

100

Load [%]

Inpu

t cur

rent

[mA]