KUAT GESER TANAH KUAT GESER TANAH BERHUBUNGAN DENGAN : A. friksi B. Kohesi : - kohesi benar - Kohesi nyata - Harus hati-hati menggunakan kuat geser tanah dalam design PENGUJIAN LABORATORIUM UNTUK MENDAPATKAN PARAMETER KUAT GESER : A. UJI KUAT TEKAN BEBAS (UNCONFINE COMP. STRENGHT) B. UJI GESER LANGSUNG (DIRECT SHEAR, SIMPLE SHEAR TEST) C. UJI TRIAXIAL
60
Embed
KUAT GESER TANAH Kuliah Mektan Tambang 20 Mei 2014
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
KUAT GESER TANAH
KUAT GESER TANAH BERHUBUNGAN DENGAN :
A. friksi
B. Kohesi :
- kohesi benar
- Kohesi nyata
- Harus hati-hati menggunakan kuat geser tanah dalamdesign
PENGUJIAN LABORATORIUM UNTUK MENDAPATKANPARAMETER KUAT GESER :
A. UJI KUAT TEKAN BEBAS (UNCONFINE COMP. STRENGHT)
B. UJI GESER LANGSUNG (DIRECT SHEAR, SIMPLE SHEAR TEST)
C. UJI TRIAXIAL
KUAT GESER TANAH
A. Faktor mempengaruhi kuat geser pasir
- Void ratio :
KUAT GESER TANAH
- Bentuk partikel:
KUAT GESER TANAH
-
KUAT GESER TANAH
-
KUAT GESER TANAH
Unconfined Compression Test
KUAT GESER TANAHLABORATORIUM MEKANIKA TANAH
FAKULTAS TEKNIK
UNIVERSITAS LAMBUNG MANGKURAT
Proyek : Perenc Teknis Jalan Lingkar Mabuun by pass Pemeriksa : Team
SP.3 Mabuari Guru Danau (Lingkar dalam perkotaan)
Tabalong
Lokasi : Maburai Tanggal : 05 Mei 2007
Sampel No. : B.I
UNCONFINED COMPRESSION TEST
Undisturbed Sampel
Sampel Area : 17.712 cm2
Sampel Length : 95.00 mm
Proving Ring No. : P-5
Calibration, 0,480 : 0.256 kg
Area
17.712 0.0000
17.801 0.2301
17.891 0.6725
17.982 1.0393
18.073 1.2748
18.166 1.4515
18.260 1.5842
18.354 1.7295
18.450 1.8454
18.547 1.9462
18.644 2.0459
18.743 2.1307
18.843 2.2145
18.943 2.3109
19.045 2.4061
19.148 2.5001
19.252 2.5797
19.464 2.7094
19.680 2.8488
19.901 2.9586
20.127 3.0908
20.359 3.1813
20.595 3.2443
20.838 3.2924
21.086 3.3144
21.340 3.3110
21.600 3.2593
21.867 3.1609
22.140
2.00
2.50
3.00
Time
0.00
0.50
1.00
Strain S (%)
1.50
5.50
6.00
6.50
7.00
3.50
4.00
4.50
5.00
11.00
12.00
13.00
14.00
7.50
8.00
9.00
10.00
19.00
20.0020.00
15.00
16.00
17.00
18.00
0.00
16.00
47.00
73.00
Unconfined
Compression
(kg/cm2)
Load P
(Kg)
P. Ring Dial 0,01
mm
0.000
113.00
124.00
133.00
141.00
90.00
103.00
179.00
187.00
194.00
206.00
149.00
156.00
163.00
171.00
261.00
268.00
273.00
276.00
219.00
230.00
243.00
253.00
275.00
270.00
4.096
12.032
18.688
23.040
26.368
28.928
31.744
41.728
43.776
45.824
47.872
34.048
36.096
38.144
39.936
3.00
3.50
69.888
70.656
70.400
69.120
62.208
64.768
66.816
68.608
0.00
0.50
1.00
1.50
2.00
2.50
4.00
4.50
5.00
5.50
49.664
52.736
56.064
58.880
8.00
9.00
10.00
11.00
6.00
6.50
7.00
7.50
16.00
17.00
18.00
19.00
12.00
13.00
14.00
15.00
KUAT GESER TANAH
LABORATORIUM MEKANIKA TANAH
FAKULTAS TEKNIK
UNIVERSITAS LAMBUNG MANGKURAT
Proyek : Perenc Teknis Jalan Lingkar Mabuun by pass Pemeriksa : Team
SP.3 Mabuari Guru Danau (Lingkar dalam perkotaan)
Tabalong
Lokasi : Maburai Tanggal : 08 November 2007
Sampel No. : B.I
UNCONFINED COMPRESSION TEST
Disturbed Sampel
Sampel Area : 17.712 cm2
Sampel Length : 95.00 mm
Proving Ring No. : P-5
Calibration, 0,480 : 0.256 kg
Area
17.712 0.0000
17.801 0.0288
17.891 0.0429
17.982 0.0712
18.073 0.1133
18.166 0.1691
18.260 0.2103
18.354 0.2511
18.450 0.2775
18.547 0.3037
18.644 0.3501
18.743 0.3961
18.843 0.4212
18.943 0.4730
19.045 0.5646
19.148 0.5348
19.252 0.5053
19.464 0.4603
19.680 0.3902
19.901
20.127
20.359
20.595
20.838
21.086
21.340
21.600
21.867
22.140
Time Strain S (%) P. Ring Dial 0,01 Load P Unconfined
0.00 0.00 0.00 0.000
1.00 1.00 3.00 0.768
0.50 0.50 2.00 0.512
2.00 2.00 8.00 2.048
1.50 1.50 5.00 1.280
3.00 3.00 15.00 3.840
2.50 2.50 12.00 3.072
4.00 4.00 20.00 5.120
3.50 3.50 18.00 4.608
5.00 5.00 25.50 6.528
4.50 4.50 22.00 5.632
6.00 6.00 31.00 7.936
5.50 5.50 29.00 7.424
7.00 7.00 42.00 10.752
6.50 6.50 35.00 8.960
8.00 8.00 38.00 9.728
7.50 7.50 40.00 10.240
10.00 10.00 30.00 7.680
9.00 9.00 35.00 8.960
12.00 12.00
11.00 11.00
14.00 14.00
13.00 13.00
16.00 16.00
15.00 15.00
18.00 18.00
17.00 17.00
20.00 20.00
19.00 19.00
KUAT GESER TANAHLABORATORIUM MEKANIKA TANAH
FAKULTAS TEKNIK
UNIVERSITAS LAMBUNG MANGKURAT
Proyek : Perenc Teknis Jalan Lingkar Mabuun by pass Pemeriksa : Team